Loading...
BSOL2015-01321), r< 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 c 'X &t4t 4 P Qumro, COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760)•777-7153 Application Number: BSOL2015-0132 Owner: Property Address: 51100 AVENIDA VELASCO LOPEZ BARBA CARLOS APN: 773065004 51100 AVENIDA VELASCO Application Description: 8.48kW PV SYSTEM - (32) 265W PANELS/(2) INVERTER LA QUINTA, CA 92253 Property Zoning: Application Valuation: $18,740.00 Applicant: Contractor: SOLARCITY CORPORATION SOLARCITY CORPORATION 3055 CLEARVIEW WAY 3055 CLEARVIEW WAY ATTN ZOE STEELE ATTN ZOE STEELE SAN MATEO, CA 94402 SAN MATEO, CA 94402 (650)963-5630 Llc. No.: 888104 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Divisi3 o/p,��e Busin s nd Professions Code, and my License is in full force and effeq/ V 1 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am•exempt from t Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who, does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Date: 9/15/2015 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' e tion, as provided for by Section 3700 of the Labor Code, for the performance k for which this permit is issued. I have and will maintain workers' compensation insurance, as required by S 700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number:_ _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I sh d beco subject to the workers' compensation provisions of Section 3700 of he abor ode, I shall forthwith comply wi h those rovisions. Date. Applicant: WARNING: AILURE TO SECURE WORKERS' COMPENSATION COVE GE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND I IL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit .issued as a result of this application , the owner, and the applicant, each agrees.to, and shall defend, indemnify and hold harmless'the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances at laws el ing to building construction, and hereby authorize representatives of thi ity o en er u on the above- menyisq��i,Qropeehy� inspection purposes. /� Date: 1: 1 Ill /1 h\ / Signature (Applicant or FINANCIAL •• • ;d ", DESCRIP,TION g� 3 f PAIDb I PAIDDATE. �`"" ACCOUNT `� a QTY ` ,;"k AMOUNT:• z .. "•_ , , i LL ....x i¢.:` BSAS SB1473 FEE, 101-0000-20306 0 $1.00 $0.00 y y� PAID BY. METHOD ;RECEIPT #� ' '�r CHECK #.� .' `aCITD , -<B Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 DESCRIPTION t ACCOUNT 1QTY s rAMOUNT 't '= PAIDN ' 4PAID DATE ,.. PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 Al '` ` $C° ��x METHOD g' ray; >;RECEIP.T# CHECK# ° «� BY?a CLTD t• _ ,. .. .. '. �.� t� S f DESCRIPTION,,;�.� ,w �Ero L - t :.•nw � T ACCOUNT -. W •_ -,f"a_ AINIOUNT -� PAID`,' -. .,. 'PAID DATE -. . aQTY PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 r ?� i taa. ` RECEIPT CHECK# CLTDBY_w y -3 aMETHOD : -_ Total Paid for ELECTRICAL: $48.34 $0.00 �DESCRIP,TIONri411-:,`A-;-s =ACCOUNT<"a. x QTY, :` �AMOUNT�':` PAID PAIDDATE m�� Y PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 : r PAID : y �s METHOD , s ' ''' g `:•RECEIPT # t 5 " ; CHECK # CLTD BYE; `: .. , .:. •+t . . t' --:.e .. 'Hz .... .YzSXf . .! rS' ....1 ri. .. a a k Total Paid for PERMIT ISSUANCE: $91.85 $0.00 • 00 Description: 8.48kW PV SYSTEM - (32) 265W PANELS/(2) INVERTER Type: SOLAR Subtype: Status: APPROVED Applied: 8/19/2015 PJU Approved: 9/8/2015 LUR Parcel No: 773065004 Site Address: 51100 AVENIDA VELASCO LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 69 Lot: 4 Issued: UNIT 9 a ., -COMPLETION Lot Sq Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $18,740.00 Occupancy Type`. Construction Type: Expired: t E-MAIL. LUIS URIBE No. Buildings: 0 No. Stories: 0 No. Unites: 0 8/27/2015 Details: 8.48kW SOLAR ARRAY - (32) 265W KYOCERA PANELS W/ (2) PVI 5000-OUTD-US-Z-A-AFCI INVERTER [480SF] 2013 CALIFORNIA ELECTRICAL CODE. EIS x n ADDITIONAL r ..__..QDITIONAL51TES, 71� CHRONOLOGY-—— x CHRONOLOGY TYPE } .. 4 STAFF NAME -. ": ACF10N DATE.: DATE , a ., -COMPLETION SENT ELENA AN EMAIL. 1ST REVIEW IS COMPLETE PLANS ARE E-MAIL. LUIS URIBE 8/27/2015 8/27/2015 READY FOR CORRECTIONS PLAN CHECK PICKED UP PHILIP JUAREZ 8/27/2015 8/27/2015 PLAN CHECK SUBMITTAL THREE SETS OF PLANS SUBMITTED PER APPLICANT ELENA` PHILIP JUAREZ 8/19/2015 . 8/19/2015 RECEIVED LOYA 442-256-1134. RESUBMITTAL PHILIP JUAREZ- 8/31/2015 8/31/2015 RESUB SOLAR CITY. CONDITIONS NAME TYPES NAME-, ADDRES51 ;,CITY; STATE ZIP PHONE'. µ FAX : '.EMAIL .� �` .,' K APPLICANT SOLARCITY CORPORATION 3055 CLEARVIEW WAY. SAN MATEO CA 94402 (760)574-6321 CONTRACTOR SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 (760)574-6321 Printed: Tuesday, September 15, 2015 4:14:09 PM 1 of 3 ` SYS7ENIS PARENT PROJECTS Printed: Tuesday, -September 15, 2015 4:14:09 PM 2 of 3 SYS TEiMS FINANCIAL •• • DESCRIPTION = "ACCOUNT QTY' AMOIINT� PAID PAID DATE MRECEIPTA' 'CHECK # METHOD ­ PAID �, re PAID BYE,, _. BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: PV SYSTEM -*ARRAY,_ 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC Total Paid for ELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:�� PARENT PROJECTS Printed: Tuesday, -September 15, 2015 4:14:09 PM 2 of 3 SYS TEiMS 2ND BLDG NS (1 ILUIS URIBE I 8/31/2015 I 9/8/2015 I 9/8/2015 • I APPROVED WK) . I T4ty� 4 4 a" COMMUNITY DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7125 FAX (760) 777-7011 Y RESIDENTIAL PLAN CHECK CORRECTION LIST (SOLAR) DATE: 8/27/15 STATUS: FIRST REVIEW PLAN CHECKED BY: LUIS URIBE TELEPHONE NUMBER: (760) 777-7015 ADDRESS: 51-100 AVENIDA VELASCO DESCRIPTION: PV SOLAR SYSTEM 1. APPLICANT: SOLAR CITY PLAN CHECK #: BSOL2015-0132 This submittal has been checked for compliance with the 2013 California Building Codes and the City of La Quinta Municipal Code. APPLICANT: The following items are being returned to you for correction: 1- SOLAR (REDLINED) PLAN 2- UNMARKED PLAN SET I - CORRECTION LIST CITY OF LA QUINTA ELOPMENT BUILDING DEPARTMENT STAFF: DO NOT. accept any resubmittal unless ALL of the following items are included: / .1 - SOLAR (REDLINED) PLAN I- CORRECTION LIST w/responses 2- REVISED PLAN SETS I - ASSESSORS SITE/FLOOR PLAN STRUCTURAL CALCS INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where -the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparers If the preparer is a licensed, architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written, responses, and all documents listed above with your resubmittal. . Residential Plan Check Correction List (SOLAR) Page 1 of 2 r r J SECTION D - STRUCTURAL' , l) Structural calculations are required for the following: a) Mountingrack spacing is over 48". Any rack mounting system spanning over 48" need site specific engineering for that roof.. Proposed spacing on plans is.72" see PV -3 sheet. SECTION E - MISCELLANEOUS COMMENTS 1) 'Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise . Plans as necessary and provide written response, noting where correction can be found. 2) Provide one copy each of the Site Plan and Floor Plan for the County Assessor's office -While not required for resubmittal, this administrative item must be addressed prior to issuance of building permit. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List (SOLAR) Page 2 of 2. In SolarC�t August 28, 2015 Project/Job # 9223980 RE: Project: To Whom It May Concern, COVER LETTER Lopez Barba Residence 51100 Avenida Velasco La Quinta, CA 92253 Version #48.9 CITY OFLA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: / - Applicable Codes = 2013 CBC, ASCE 7-10, and 2012 NDS - Risk Category = II l<� �- - Wind Speed = 110 mph, Exposure Category C - Ground/Roof Snow Load = 0 psf - MP1: Roof DL = 14 psf, Roof LL 19.5 psf - MP2: Roof DL = 19 psf, Roof LL = 19.5 psf aJ dQ O O On the above referenced proje`Act, components of the structural roorfrfra;JR impacted by the installation of the PV assembly have been reviewed. After this.r`e a has been determined that the exis 'r tructure is adequate to withstand the applicable roof dead load, PV assembly load,�ancLlive/snow loads indicated in the design ha above. � a �a The structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the 2013 CBC. Please contact me with any questions or concerns regarding this project. Marcus Hecht -Nielsen, P.E. Professional Engineer T: 858.225.2621 email: mhechtnielsen@solarcity.com Digitally signed by Marcus Hecht -Nielsen Date: 2015.08.28 16:41:23 -07'0( 3055 Clearview Way San Mateo, CA 94402 T (650) 638-1028 (888) SOL -CITY F (650) 638-1029 solarcity.com AZ ROC 243771. CA CSLB 888104.00 EC 8041. CT HIC0632778. DC HIC 71107488. DC Ht6 71101488, HI CT•29770. MA HIC 168572. MD MHIC 128948, NJ mH08160600. OR CCB 180498, PA 077343. TX TOL R 27008: wA GCL: SOL ARC'91907. O 2013 SolarGty. Au rlphto rewmed. .� e: =tr a.� '�f�,= � •ate 1 i• i r e �i ' . ��}• t '; Y a �_ "• � � tia �--.3 :•� r o -s.. r r � � a • t. a e l •� � � '- -ie „�, 1 y.Fi �, - _ r i"f ' .: e• ilio -1•' iw : Q ..5* t.• '� '�.. 'ili � M'i !, I� iv � �' � � w �f r `T s: s ' /• �• � J.Y'.. ..{, • "'.7- J,i. a �, •� w a .o �. $fl s i+ '� -=t'- ... r r • '� �� to cam �,a G s �r •" a �� � -� �� , i�, .a s�. �� _ — i � , 7 wf c �t �' - ... _', r r+• -w SV �i a K. �• e. a � .•,a �a s J � S .. � 1 l u. O w 1" I• 4 � "1 � � Y' t .'r i .a.. i�a. _ v �► -F� �, _ _d � a � = , C611e.Sinaloa._ <- < 1 A 1, � (��> . a _ v��• �V i�r � _ ate" w-..[."�.�r' i. � •, yaw ��j C' Go p` 'd a6 mDigitiQdobT USDA Farm dery ce AgeriCy 0 Seismic Design, Criteria(per USGS)' Seismic Design Code 'Area ASCE 7-10 IBC Sect. 3404.4 Latitude 33.6774 3 psf I 1 700 lbs Longitude Total Weight of PV System -116.3087 1 1,700 lbs SRA at Short Period SS ._'�' 1.515 USGS SRA at is Period - S, 0.600 USGS Soil Site Class D Seismic Desi n Category SDC D USGS Seismic Check Required.(Ss z 0.4q &SDC >_ D)? Yes IBC 1613.1 ALTERATION LATERALDESIGN .10% EXCEPTION CHECK Weight of Proposed PV System Sum Area of MPs with PV 'Area Dead Load:�j Load:.,Weight IBC Sect. 3404.4 PH System Weight ' 567 sf 3 psf I 1 700 lbs Roof Total Weight of PV System W(PV') 1 1,700 lbs ? Weight of Roof on Existing Building Sum Area of MPs with PV IBC Sect. 3404.4 Portion of Roof Weight Area Dead Load Weight Roof 14.0 psf Ceiling 5.0 psf Interior Walls (Top Half) 5.0 psf Exterior Walls o Hal 8.5 psf Net Weight of Roof Under PV "; W(exist) Check %Increase of Roof Weight /Seismic Shear load %Increase of DCR of Lateral • • • - • .: NA • Force Resistin stem. " W(PV)/ WteXi? >10% Seismic Analysis R wired Note: Seismic base shear is directly or000rtional to roof weiaht. IBC Sect. 3404.4 Check %Increase of Roof Weight /Seismic Shear load %Increase of DCR of Lateral • • • - • .: NA • Force Resistin stem. " W(PV)/ WteXi? >10% Seismic Analysis R wired Note: Seismic base shear is directly or000rtional to roof weiaht. STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP1 Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2) 2. pf = 0.7 (Ce) (CO GO pg; Ce=0.9, Ct=1.1, I5=1.0 Member Desi n Summa er NDS Governing Load Comb CD CL + CL - CF Cr D + Lr 1.25 1.00 0.95 1 1.5 1.15 Member Properties Summary Summa ] Maximum MPI Horizontal Member Spans Overhang 1.57 ft Rafter Pro erties Actual W 1.50" Roof System Proerties San 1 4.73 ft Actual D 3.50" Number of Spans (w/o Overhang) 4 San 2 4.04 ft Nominal Yes Roofing Material Spanish Tile Roof San 3 4.64 ft A 5.25 in.^2 Re -Roof No Span 4 5.78 ft S. 3.06 in A3 Plywood Sheathing Yes San 5 24.5 psf I 5.36 in.^4 Board Sheathing None Total Span 20.76 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 2.17 ft Wood Species DF Ceiling Finish 1/2" Gypsum Board PV 1 End 14.58 ft Wood Grade #2 Rafter Sloe 200 PV 2 Start Fb 1 900 psi Rafter Spacing 24" O.C. PV 2 End F„ 180 psi Top Lat Bracing Full PV 3 Start E 1600000 psi Bot Lat Bracing At Supports PV 3 End Emig 580000 psi Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2) 2. pf = 0.7 (Ce) (CO GO pg; Ce=0.9, Ct=1.1, I5=1.0 Member Desi n Summa er NDS Governing Load Comb CD CL + CL - CF Cr D + Lr 1.25 1.00 0.95 1 1.5 1.15 Member Loading Summa ] Maximum Roof Pitch 5/12 Initial Pitch Adjust Non -PV Areas PV Areas Roof Dead Load DL 14.0 psf x 1.06 14.9 psf 14.9 psf PV Dead Load PV -DL 9.0 Psf x 1.06 17.6 ft. 9.6 psf Roof Live Load RLL 20.0 psf x 0.98 19.5 psf 14.5 ft. Live/Snow Load LL/SL 1,2 D + Lr Total Load Deflection 0.13 in. I LJ568 Total Load(Governing LC I TL 1 0.21 1 34.4 psf 1 24.5 psf Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2) 2. pf = 0.7 (Ce) (CO GO pg; Ce=0.9, Ct=1.1, I5=1.0 Member Desi n Summa er NDS Governing Load Comb CD CL + CL - CF Cr D + Lr 1.25 1.00 0.95 1 1.5 1.15 Member Anal sis Results Summary ] Maximum Max Demand Q Location Capacity DCR Load Combo Shear Stress 61 psi 1.6 ft. 225 psi 0.27 D + Lr Bendin + Stress 753 psi 17.6 ft. 1941 psi 0.39 D + Lr Bendin - Stress -821 si 14.5 ft. -1838 psi 0.45 D + Lr Total Load Deflection 0.13 in. I LJ568 17.3 ft. 0.62 in. 120 0.21 D + Lr �CALCUI:ATION=OF'DESIGN WIND_LOADS - MP1_ Mounting Plane Information ".4ti. Roofing Material ' KZ Spanish Tile Roof Table 30.3-1 PV System Type _ SolarCity SleekMounem _Section 26.8— Spanning Vents V Yes Fig. 26.5-1A Standoff Attachment Hardware I 5M The Section 26.7 Roof Slope qh 200 - - Rafter Spacing h 24" 09C.— Section 26.2 Framing Type Direction Y -Y Rafters T -allow Purlin Spacing X -X Purlins Only - NA DCR Tile Reveal Tile Roofs Only 13" Tile Attachment System —Tile -Roofs Only SM Tile ,Standing Searn/Trap Spacing SM Seam Only NA Wind iDesign, Criteria - Wind Design Code ' KZ ASCE 7-10 _ Table 30.3-1 Wind.Design Method __ _ Partially/Fully Enclosed Method _Section 26.8— Basic Wind Speed V 110 moh Fig. 26.5-1A Exxposure.Category I C Section 26.7 Roof Style qh Gable Roof Fig. 30.4-2A/B/C-5A/B Mean Roof Height h 15 ft Section 26.2 Wind Pressure Calculation Coefficients - Wind Pressure Exposure ' KZ 0.85 Table 30.3-1 Topographic Factor N Krt� 1.00 _Section 26.8— Wind Directionality Factor Kd 0.85 Section 26.6-1 -Importance Factor I NA Trib Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 psf Equation 30.3-1 Wind Drocceiro Ext. Pressure Coefficient U G u -0.88, . Fig. 30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down G w 0.45 Fig. 30.4-2A/B/C-SA/B Design Wind Pressure p p = % (GC) Equation 30.4-1 Wind Pressure Up PfUD)-19.6 psf Wind Pressure Down 16.0 psf i . ALLOWABLE STANDOFF SPACINGS X -Direction - Y -Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Not -Staggered Max Standoff Tributary_Area Trib 19 sf _ PV Assembly Dead Load . W -PV 3.0 psf Net Wind Uplift at Standoff Tactual -196 lbs Uplift Capacity of Standoff T -allow 446 lbs Standoff Demand Ca aci DCR 43.90/6 X -Direction = Y -Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable.Cantilever ' Portrait -19.1-_ _ _ _ NA Standoff Configuration Portrait Not -Staggered Max Standoff Tribute_ry_Area Trib 22 sf _ PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff Tactual_ '-219 lbs Uplift Capacity of Standoff T -allow 446 lbs Standoff Demand/Capacity DCR 49.1% STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP2 Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2] 2. pf = 0.7 (Ce) (CO (IS) pg; Ce=0.91 Ct=1.1, I5=1.0 Member Design Summa(per NDS Governing Load Comb CD CL + CL - CF Cr D + Lr 1.25 1.00 1 0.95 1 1.5 1.15 Member Properties Summary Summa Maximum MP2 Horizontal Member Spans Overhang 1.57 ft Rafter Pro erties Actual W 1.50" Roof System Prope San 1 4.59 ft Actual D 3.50" Number of Spans (w/o Overhan 4 San 2 4.11 ft Nominal Yes Roofing Material Spanish Tile of San 3 4.64 ft A 5.25 in.^2 Re -Roof No San 4 5.79 ft SX 3.06 in A3 Plywood Sheathing Yes San 5 24.5 psf I 5.36 in.^4 Board Sheathing None Total Span 20.70 ft TL Deffn Limit 120 Vaulted Ceiling No PV 1 Start 3.33 ft Wood Species DF Ceiling Finish 1/2" Gypsum Board PV 1 End 15.75 ft Wood Grade #2 Rafter Sloe 200 PV 2 Start Fb 900 psi Rafter Spacing 24" O.C. PV 2 End F„ 180 psi Top Lat Bracing Full PV 3 Start E 1600000 psi Bot Lat Bracing At Supports PV 3 End E,„i„ 580000 psi Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2] 2. pf = 0.7 (Ce) (CO (IS) pg; Ce=0.91 Ct=1.1, I5=1.0 Member Design Summa(per NDS Governing Load Comb CD CL + CL - CF Cr D + Lr 1.25 1.00 1 0.95 1 1.5 1.15 Member Loading Summa Maximum Roof Pitch 5/12 Initial Pitch Adjust Non -PV Areas PV Areas Roof Dead Load DL 14.0 psf x 1.06 14.9 psf 14.9 sf PV Dead Load PV -DL 9.0 psf x 1.06 17.5 ft. 9.6 psf Roof Live Load RLL 20.0 psf x 0.98 19.5 psf 14.4 ft. Live/Snow Load LL/SL 1,2 D + Lr Total Load Deflection 0.13 in. 572 Total Load(Governing LC I TL 1 0.21 1 34.4 psf 1 24.5 psf Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2] 2. pf = 0.7 (Ce) (CO (IS) pg; Ce=0.91 Ct=1.1, I5=1.0 Member Design Summa(per NDS Governing Load Comb CD CL + CL - CF Cr D + Lr 1.25 1.00 1 0.95 1 1.5 1.15 Member Anal sis Results Summary Maximum Max Demand @ Location Capacity DCR Load Combo Shear 64 psi 1.6 ft. 225 psi 0.29 D_+ Lr -Stress _ _ Bending + Stress 749 psi 17.5 ft. 1941 psi 0.39 D + Lr Bending - Stress -803 psi 14.4 ft. -1838 psi 0.44 D + Lr Total Load Deflection 0.13 in. 572 17.3 ft. 0.62 in. 120 0.21 D + Lr } [CAL'CUL'ATION OF'DESIGN WIND_LOAD9MP2 _ Mountin iPlane 'Information Roofing Material KZ Spanish Tile Roof Table 30.3-1 PV System Type Wind Pressure U SolarCity SleekMounFm _Sect6n.26.8, Spanning Vents V Yes Fig. 26.5-1A Standoff Attachment Hardware NA M T' —Section 26.7 Roof Slope qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 psf 200 Fig. 30.4-2A/B/C-5A/B Rafter pacing h 24" O.C. Section 26.2 Framing Type • Direction Y -Y Rafters T -allow Purlin Spacing -X-XPurlins Only NA DCR Tile Reveal Tile Roofs Only 13" Tile Attachment System . Tiile.Roofs.Only __Tile. SM Tile StandingSeam/Trap Spacing Seam Only I NA Wind, Design! Criteria Wind Design Code KZ ASCE 7-10 Table 30.3-1 Wind.Design.Method Wind Pressure U Partially/Fully Enclosed_ Method _Sect6n.26.8, Basic Wind Speed V 110 mph Fig. 26.5-1A Exposure.CateggN NA C —Section 26.7 Roof Style qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 psf Gable Roof Fig. 30.4-2A/B/C-5A/B Mean Roof Height h 15 ft Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 30.3-1 Topographic.FactorKrt� Wind Directionality Factor Wind Pressure U 1.00 _Sect6n.26.8, Kd , 0.85 Section 26:6-1 Importance Factor I NA Max Standoff Tributary -Area Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 psf Equation 30.3-1 Wind Pressure Ext. Pressure Coefficient U GC -0.88 Fig. 30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down G W 0.45 Fig. 30.4-2A/B/C-5A/B Design Wind Pressure p p = qh (GC) Equation 30.4-1 Wind Pressure U -19.6 psf Wind Pressure Down 16.0 psf ALLOWABLE STANDOFF SPACINGS ' X -Direction Y -Direction Max Allowable StandoffSpacing Landscape 72" 39" Max Allowable Cantilever __Landscape_ 24" NA Standoff Configuration Landscape Not -Staggered Max Standoff Tributary -Area Trib 19 sf f: PV Assembly Dead Load W -PV 3.0 psf NetNet Wind.Uplift at Standoff T_actual� -19616s Uplift Capacity of Standoff T -allow 446 lbs Standoff Demand/Capacity DCR 43.90/6 X -Direction Y -Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable.Cantilever Portrait 19" NA Standoff Configuration Portrait Not -Staggered Max StandoffTributary-Area: Trib 22 sf f: PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff_ T -actual -219 His Uplift Capacity of Standoff T -allow 446 lbs Standoff Demand/Capacity DCR 49.1% F• GROUND SPECS _ MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE OND (N) #8 GEC TO (E) LIFER AT PANEL Panel Number: WMB101224S Inv 1: DC Ungrounded INV1 -()ABB' PVI-5000-OUTD-US-Z-A A -02)KYOCERA # KU2656ZPA CA #888104 WITH IRREVERSIBLE CRIMP Meter Number: 58030695 Inv 2: DC Ungrounded FCI Inverter, Zigbee SOOOW, 24ov, PV Module; 265W, 238.1W PTC, 40MM, Blk Frm, H4, ZEP, 1000V, Blk Cell, io Bockbar C-10 Underground Service Entrance INV,2 - (1 ABB PVI-3.D-OUTD-S-US-Z-A B FCI Inverter, Zigbee 3000W, 24OV,,96% Voc: 36,3 Vpmax: 31 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 125A MAIN SERVICE PANEL E; 10OA/2P MAIN CIRCUIT BREAKER/ /' BRYANT ADJUST MIN. 'ACTIVATION VOLTAGES! SolarCity / CUTLER -HAMMER (N) 125A Load Center Inverter 1 IND S 1 10OA/2P _ Disconnect 9 7 ABB PVI-5000-OUTD-US-Z-A DC+ Vstart = 120V DG MP 1: 1x11 (E) LOADS g 7C- 30A/2P ------ - - - - L, 24ov r --------- -- -- - - - - -- - - E�------------ - ----� L2 DC+ " 50A/2P GND -- - - EGG DCn r - 4 ZDC+ Vstart = 120V _ _ _ _ A I - -,• r ---------------- _-------- - GEC ---�� DC,11 G MP 1: 1x11 GND -- EC -'C--- --------- ------------ - ------ --- ---- --- --- -- -----� ADJUST MIN. ACTIVATION VOLTAGES!, (1)Conduit Kit; 3/4' EMT " Inverter 2 PAR - EGGGEC -� I $ ABB PVI-3.0-OUTD-S-US-Z-A. • i 20A/2P _ - GEC - -- Ll 24DV TO 120/240V I PHASE i SERVICE I I - ---------------------------- N EGG DC+ - GEC ---�� DC- Vstart = 120VSINGLE Dc+U1ILITY 6 jEr-_C DG MP 2: 1x10 . GND -- EC -'C- - - - - - - - - - - - - - - - - - - - - - - ---- ------------------� PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND .GROUPED. THE MEANS OF IDENTIFICATION SHALL BE • PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, _ TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS. + INDICATE IF THE COMBINING PROCESS TAKES PLACE IN THE ' INVERTER. Voc* = MAX VOC AT MIN, TEMP t • POI(1) CUTLER-HAMM OC 502120 Pv BACKFEED BREAKER Breaker, 2OA1P-SOA�2P-20A/1P, 2 Spaces, aadplex (1)Ground Rod; 5/8* 8', Copper (1) CUTLER -HAMMER 0 DG222URB Disconnect; 60A, 240Vac, Non -Fusible, NEMA 3R AC - (1)CUTLER- AMMER DG100N8 e (1) SolarCity 4 STRING JUNCTION BOX 2x2 STR GS, UNFUSED, GROUNDED DC - x - Ground%Neutral Kit- 60-100A. General Duty (DG) C (1)BRYAN T g BR48025RP 1 Load Center, 125A, 120/24OV, NEMA 3R - (1)CUTLER-HAMM B BR230 Breaker, 30A 2P, 2 Spaces y - (1) Break r,H 20A 2P. 2 Spaces 1 AWG jB, THWN-2, Black O Ic?F (1)AWG �8, THWN-2, Red (1)AWG #B:THWN-2, White NEUTRAL Vmp =240VAC Imp=37.5 AAC O (1)AWG #10, THWN-2, Black LCL (1)AWG #16, THWN-2, Red (1)AWG'#10, THWN-2, White j. NEUTRAL Vmp =240 VAC Imp=23 AAC 1)AWG 110, THWN-2, Block Voc* = 474.38VDC Isc = 9.26 ADC(2)AWG ® (1)AWG /10, THWN-2, Red Vmp -341 VDC Imp= 8.55 ADC (1 AWG /10, THWN-2,,Green. EGC g10, PV Wire, 60OV, Block O (1) AWG g10, Solid Bare Copper ECC , Voc* = 474.38VDC Isc = 9.26 ADC Vmp = 341 VDC Imp= 8.55 ADC ...... 70 AN �,• THWN-2,• Been , . EGC/GEC .- 0 ) Conduit. Kit; . 3/4' .EMT.. , • • , • • , • ..... • . - (1 AWG �8,. TH.WN-2,• Green • , (1)AWG #10, THWN-2; Black EGC/GEC - (1) Conduit• Kit;. 3/4' ,EMT..... , ... ;, ! (1 AWG #10, THWN-2, Black Voc* = 474.38VDC Isc = 9.26 ADC k n O (1) AWG /10, THWN-2, Red Vmp = 341 VDC Imp= 8.55, ADC O (2) AWG 06, PV Wire, 600V, Bladk (1) AWG 810, Solid Bare Copper EGC LJ Voc* = 474.38 VDC Isc = 9.26 ADC Vmp = 341 VDC Imp= 8.55 ADC O (1 )AWG #10, THWN-2, Red (1 AWG #10, THWN-2,,Green• . EGC....... . (1 )AWG X10, 1HWN-2, White -.0 Air! #8,. THWN-2,• Green NEUTRAL Vmp =240 VAC Imp=14.5 AAC(1 EGC/GEC (1 ) Conduit. Kit;. 3/4' „ . . ........................ AWG #10, THWN-2, Black Voc* = 431.26 VDC Isc = 9.26 ADC © (1) AWG #10. THWN-2, Red Vmp = 310 VDC Imp= 8.55 ADC (2 ) AWG 810, PV Wire, 60OV, Block O (1) AWG $10, Solid Bare Copper EGC Voc* = 431.26 VDC Isc = 9.26 ADC Vmp = 310 VDC Imp= 8.55 ADC • , .. ,- ,EMT. , . , .. , . _ 1) AWG /10, THWN-2.. Green.. EGC .... (t) ConAuit. Kit:. 3 . .EMT..:....... ................................................................ . CONFIDENTIAL -THE INFORMATION HEREIN _CONTAINED SHALL NOT BE USED FOR THE •LOPEZ OF SOLARCITY CIN YONEBEDISCLOOSSED JB -9223980 0 0 Joe NUMBERMark PREMISE OWNER: DESCRIPTION: BARBA, CARL08 LOPEZ BARBA RESIDENCE OFSIG1t Williams ��'Qlar��t\/ ''" MouNntic SYSTEM: NOR SHTALL ITN WHOLE ORT ZEP ZS Tile WTile 51100 AVENIDA VELASCO 8.48 KW PV ARRAY 1° PART TO OTHERS OUTSIDE THE RECIPIENTS LA QUINTA CA 92253 MODULES: 3oss aekrview way San Mateo, CA 94402 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (32) KYOCERA # KU2656ZPA PAGE NAME SHEEP RLV. DATE NVulti Multiple Inverters SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC 76O 574-6321 (� - � THREE LINE DIAGRAM - - PV 5 . 8/18/2015 (888) SOL -050) ITY (165-2489)�wwMssdar10iycom ELECTRICAL CALCULATIONS Module: 22 Kyocera 265W 1000V 238.1 Inv Power WPTC Voltage Drop Calculations Version 5.8.0 1 ABB PVI -5000-S AFCI 0.96 5000 5054.86 Inverter 1: Vdrop = 2 * Length) Resistance / Vmp) Module: 10 Kyocera 265W 1000V 238.1 A Max. Length ftWire Inverter 2: 1 ABB PVI -3.0-5 AFCI 0.96 3300 2285.76 Z8.55 String: 25 AWG #10 at Max Ave Hi: 109 deg F Module: Vdrop = 50 0.00124 Ohms / 261.18 0.2 Branch: 5 50 AWG #10 at Max Ave Hi:109 deg F Vdrop = (8.55 100 0.00124 Ohms) / 310 0.41 7-1 Total voltage dro in DC conductors = 0.61 Inverter: 14.5 10 1 AWG #10 of 240V K ocera 265W 1000V 238.1 Inverter 3: Module: Kyocera 265W 1000V 238.1 Inverter 4: Total: 32 Modules Total Inv Pwr: 8300 7340.62 1 PTC Vdrop = 14.5 •-20 0.00124 Ohms / 240 V 0.09 Combinedi 30 15 1 AWG #8 at 240V Photovoltaic Module Electrical Specifications: Total STC:1 8480 Vdrop = 30 30 0.00078 Ohms) / 240 V 0.17 Voc: 38.3 V deg F deg C " Vmp: 31 V Record Low Temp: 14 -10 Total voltage drop in AC conductors = 0.25 Isc: 9.26 A Max Average Hi Temp: 109 143 Total voltage drop in AC and DC conductors = 0 Imp: 8.55 A Record Hi Temp: Tvoc: -0.14 V/deg C Tisc:l 5.56 1 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf TVoc Data Branch Circuit Type A 1 way wire length: 50 Voc Correction Factor: ABB PVI -3.0-S AFCI . 10 Kyocera 265W 1000V _. Inverter Min Vdc Input: Min Vmp at Max Temp: Voc= 383 Max Voc at Min Temp: Vmp= 310 Inverter Max Vdc Input: Isc= 9.26 Max String Size: Imp= 8.55 Icont= 11.58 Art 690.8(A)(1) 1 -way wire length: 1 strings per branch 1� strings per branch 2 10 modules per series string modules per series string Voc= 383 V Voc= V Vmp= 310 V Vmp= V Isc= 9.26 A Isc= A Imp= 8.55 A Imp= A (cont= 11.58 A (cont= A Art 690.8(A)(1) 130 261.18 431.26 600 13 50 1.a Conductor:1 AWG #1U PV Wile 7 a Conductor 1: AWG #10 Conductor 2: (cont * 1.25 = (Amps) 14.47 Conductor t Conductor 2 30 deg C ampacity = 401 Icont * 1.25 = (Amps) 14.47 1.b Icont= (Amps) 11.58 30 deg C ampacity = 40 Start ampacity 40 2.b Icont= (Amps) 11.58 40 Temperature derate (%=F) 0.41 Start ampacity 0.41 Conduit fill derate (%_#) 1 Temperature derate (%=F) 1 Derated ampacity 16.4 E Conduit fill derate (%_#) 1.c 16.4 Derated ampacity 2.c Term 1 Term 2 (cont * 1.25 = (Amps) 14.47 Ampacity 40 Temp table 90 *C:Tab a 310.15 (16) (cont*1.25= (Amps) 14.47Ampacity 40 1.d Icont * 1.25 = (Amps) OCP Size = 14.47 15 Inverter Type A Output 2.d OCP Size 1 151 1 Combined Inverter Output ABB PVI -5000-S AFCI 1 way wire length: 10 ft Icont = 23 FA Art 690.8(A)(1) Service Voltage= Total Inverter Powe - 1 way wire length= 15 3.a Icont * 1.25 = (Amps) 28.75 Art 690.8(B)(1) 30 OCP Size = Art 240.6(A) Icont = # of inverters*max inverter current Art 690.8(A)(1) Icont = (Amps) 3.b Conductor: AWG #10 Icont' 1.25 = (Amps) 30 deg C ampacity = THWN•.2 at 90 deg C: Table 310.16 28.75 40 E 4.a Icont*1.25 = (Amps) OCP size 46.88 Art 690.8(B)(1) Art 240.6(A) 1 501 3.c Icont = (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%_#) Derated ampacity 23 4.b Conductor: AWG #8 Icont * 1.25 = (Amps) 30 deg C ampacity = THWN-2 at 90 deg C: Table 310.16 46.88 55 40 0.91 1 4.c Icont = (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%_#) Derated ampacity 37.5 36.4 55 3.d Icont * 1.25 = (Amps) 28.75 Ampacity 35 0.91 1 50.05 4.d Icont * 1.25 = (Amps) 46.88 50 Ampacity CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE No SHTOF ALL IT YONE BE DISCLOSED SOLARCITY N WHOLE ORCIN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC JOB NUMBER JB -9223980 00 PREMISE OWNER: LOPEZ BARBA, CARLOS 51100 AVENIDA VELASCO LA QUINTA, CA 92253 (760) 574-6321 DESCRIPTION: LOPEZ BARBA RESIDENCE 8.48 KW PV ARRAY PAGE NAME ELECTRICAL CALCULATIONS DESIGN: Mark Williams SolarCit 'A . MOUNTING SYSTEM: ZEP ZS Tile WTile . -- MODULES: (32) KYOCERA # KU2656ZPA M aeoNl°" Way Son T:(65O) 638-1028, CA 9440 638-1029 (Bn)-SOL-CITY (765-2489) www.sd°rcity.com SHEET: REN DATE: PV 6 8/18/2015. INVERTER: Multiple Inverters PITCH: 20 ARRAY PITCH: 20 MP1 AZIMUTH: 90 ARRAY AZIMUTH:.90 , MATERIAL: Low Profile W -Tile STORY: 1 Story PITCH: 20 ARRAY. PITCH: 20�/� MP2 AZIMUTH: 270 ARRAY AZIMUTH: 270 - MATERIAL: Low Profile W -Tile STORY: 1 Story . Oil 3' FSB 3' FSB -----� F ----------- o v (E) DRIVEWAY LEGEND C) I E I (E) UTILITY METER & WARNING LABEL Ln s� h _ LPtW ® c Ing INVERTER W/ INTEGRATED DC DISCO ® TI ❑ & WARNING LABELS NIW WI � DC DISCONNECT & WARNING LABELS > I I © AC DISCONNECT & WARNING LABELS Front Of HOUSe. I A Q DC JUNCTION/COMBINER BOX & LABELS i - .RANSFORMER INFORMATION: Q DISTRIBUTION PANEL & LABELS F I �q.AA PHASE B _` Lc LOAD CENTER & WARNING LABELS :IGH KV •. �' � -. _ _. (�W 120/240V I '- c> DEDICATED PV SYSTEM.. METER p; ETER# 58030695 — -" — — — — — — `�600POSED BI-DIRECTIONAL . — TIONS 3' FSB 3' FSBSTANDOFF LOCA CONDUIT RUN ON EXTERIOR t TER# 58030695 CONDUIT RUN ON INTERIOR 'CONNECT_BRAND_MODEL o Inv' Inv M — GATE/FENCE - AC O O O 0 HEAT PRODUCING VENTS ARE RED IS�ONNECT: CUTLER -HAMMER a AC r' -, LE '� ' INTERIOR EQUIPMENT IS DASHED i FT FROM MAIN PANEL - - - 200A, 24OV,"SING PHASE, � -•� LC 0 2 WIRES, 22kAiC T N g n EXISTING BI DIRECTIONAL SITE PLAN -METER 58030695 INVERTER: ABB, ABB # x w Scale: 1/8" = 1' � W E 0 1' 8' 16' 10115-1/1 g i� � PREMISE OWNER: DESCRIPTION: TESIGN: CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER J [3-9223980 00 J- \\k CONTAINED SHALL NOT BE USED FOR THE LOPEZ BARBA, CARLOS LOPEZ BARBA RESIDENCE Mark Williams �.�`� BENEFlT;OF ANYONE EXCEPT SOLARgTY INC., MOUNTING SYSTEM: �j;;SOiarClty NOR MALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile WTile 51100 AVENIDA VELASCO 8.48 KW PV ARRAY f . PART IZ OTHERS EXCEPT IN THE RECIPIENT'S MODULES: LA QUINTA CA 92253 ORGANIZATION, EXCEPT IN CONNECTION WITH , JIM Cle�vle� Way THE SALE AND USE OF THE RESPECTIVE (32) KYOCERA # KU2656ZPA PAGE NAME: SHEET; REV: DATE' San Mateo, CA 94402 SOLARgTY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650) 638-1028 F:(650) 638-1029 ?> PERMISSION OF SOLARCITY INC. . MUItI le Inverters (760) 574=6321 SITE PLAN PV 2 8/18/2015 (BBB) -SOL -CITY (765-2489) m.n.solarcfly.aam ABBREVIATIONS I ELECTRICAL NOTES 1 JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET—BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT 1. THIS SYSTEM IS GRID—INTERIIED VIA A UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY—RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. LICENSE GENERAL NOTES CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. I MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: La Quinta ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE UTILITY: Imperial Irrigation District COVER SHEET Ism PV2 SITE PLAN CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER J B-9223980 00 PREMISE OWNER. LOPEZ BARBA, CARLOS Mou"¶"� SYSTEM: ZEP ZS Tile WTile NO SHTOF ALL ITYONE BEDISCLOSED N WHOLE ORT SOLARCITY CIN 51100 AVENIDA VELASCO PART TO OTHERS OUTSIDE THE RECIPIENT'S LA QUINTA, CA 92253 MODULES ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (32) KYOCERA # KU2656ZPA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. (760) 574-6321 INVERTER: Multiple Inverters RECEIVED AUG 19 2015 CIT`' ()F � QUINTA COMMU tr ��,� pEVELOPMENT VICINITY MAP DESCRIPTION: LOPEZ BARBA RESIDENCE 8.48 KW PV ARRAY PAGE NAME: COVER SHEET INDEX PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM PV6 ELECTRICAL CALCULATIONS Cutsheets Attached �w REV BY DATE COMMENTS REV A NAME I DATE COMMENTS x x x x x x x x Mark Williams SHEET': REV: WE- PV ATEPV 1 8/18/2015 W �; ;SolarCity. �I 3055 Clearvlee Way San Mateo, CA 94402 T:(650) 636-1028 F:(650) 638-1029 (888) -SOL -QTY (765-2489) www.solarcity.com (E) 2x4 (E) 2x4 f INSTALLATION ORDER " DIA THREADED STUD REMOVE TILE, LOCATE & MARK & NUT (1) RAFTER LOCATIONYLACE STANDOFF BASE & DRILL PILOT HOLES. ZEP LEVELING FOOT ______— — — — — —_—————— — — — — —_ - ZEP TOP ARM 2) CLEAN PAPER AROUND PILOT HOLE. ! ZEP ANTI—ROTATION PLATE (6) M10 BOLTS SEAL PILOT HOLES AND BOTTOM OF _ ' MOUNTING BASE (5) (3) STANDOFF WITH POLYURETHANE E- (E) TILE (1) SEALANT.. + . - - (E) ROOF DECKING (4) LAG STANDOFF BASE INTO RAFTER. (E) RAFTER (4) (2) U U (3) 5) PLACE FLASHING AND ATTACH f STEEL LAIABSTAILES SEALING SPACER WITH SINGLE BOLT. EMBED, MIN) < (6)PLACE ZEP BAR. THEN INSTALL LEVELING FOOT WITH BOLT & WASHER. t STANDOFF Scale: 1 1/2" = 1' • CONFIDENTIAL THE INFORMATION HEREIN � SHALL NOT BE USED FOR THE BENEFIT JOB NUMBER: J B-9 2 2 39 80 0 0 PREMISE OWNER: LOPEZ BARBA, CARLOS DESMPTIDN: LOPEZ BARBA RESIDENCE DSM Mark WIIIiOrnS � �;,;SOIa�CIty. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., O NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S MOUNTING SYSTEIk ZEP ZS Tile WTile 51100 AVENIDA VELASCO LA QUINTA CA 92253 8.48 KW PV ARRAY �:... ORGANIZATION, EXCEPT IN CONNECTION WITH uoouLEs ' THE SALE AND USE OF THE RESPECTIVE (32) KYOCERA # KU2656ZPA PACE NAME SHEET: REV. DATE 3055 CIeurNeM Way Son Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. INMTER Multiple Inverters - (760) -574-6321 STRUCTURAL VIEWS PV 3 8/18/2015 (888) -SOL -CITY (7658-2�jwww� Idptyoom 2" MAX VENT SPANNING DETAIL DIAMETER NTS SOLAR PANEL SOLAR MODULE MOUNTING HARDWARE (SEE STANDOFF DETAIL) ROOFING MATERIAL PLYWOOD (E) RAFTER SPANNING PHOTOVOLTAIC MODULES OVER VENTS MINIMUM VENT HEIGHT IS 6" ABOVE THE SURFACE OF THE ROOF PER 2007 CPC SECTION 906.1. 2" MIN CLEAR SPAN ATO UNDERSIDE OF MODULE 6" MIN. VENT HEIGHT FROM TOP , OF ROOFING MATERIAL VENT PIPE 2013 CPC 310.5 STATES 'NO FITTING, FIXTURE, AND PIPING CONNECTION, APPLIANCE, DEVICE, OR METHOD OF INSTALLATION THAT OBSTRUCTS OR RETARDS THE FLOW OF WATER, WASTES, SEWAGE, OR AIR IN THE DRAINAGE OR VENTING SYSTEMS IN AN AMOUNT EXCEEDING THE NORMAL FRICTIONAL RESISTANCE TO FLOW, SHALL BE USED UNLESS IT IS INDICATED AS ACCEPTABLE IN THIS CODE OR IS APPROVED IN ACCORDANCE WITH SECTION 301.1 OF THIS CODE." FROM THIS SECTION, IT IS CLEAR THAT MOUNTING SOLAR MODULES OVER A VENT IN A MANNER THAT WILL NOT HAVE A GREATER FRICTIONAL RESISTANCE TO AIR FLOW WOULD BE ACCEPTABLE. EQUATIONS: THE FRICTIONAL RESISTANCE TO FLOW IS DIRECTLY PROPORTIONAL TO THE AREA THAT THE AIR CAN FLOW THROUGH. IN THE VENT, THAT IS THE CROSS-SECTIONAL AREA OF THE VENT PIPE: Avent = 1T*R 2 WHEN THE AIR EXITS THE VENT, THE AREA IT HAS TO FLOW THROUGH IS THE CIRCUMFERENCE OF THE VENT TIMES THE VERTICAL DISTANCE BETWEEM THE VENT AND THE MODULE ABOVE (IN THIS CASE, WE ARE LEAVING THE DIAMETER BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE PANEL). THIS METHODOLOGY ASSUMES THE WORST CASE SCENARIO OF MOUNTING THE MODULES HORIZONTALLY OVER THE VENT. IN ACTUALITY, THE MODULES WILL BE TILTED WHICH WILL OFFER MORE AREA FOR AIR TO FLOW THROUGH. Agap = C*CLEARANCE = (IT*D)*D = (TT*2*R)*(2*R) = 4*1T*R2 4*7f*R2 > WR2 FROM THE EQUATIONS ABOVE, IT IS EVIDENT THAT MOUNTING THE MODULES IN THIS MANNER ALLOWS FOUR TIMES THE AMOUNT OF AIR FLOW ABOVE THE VENT THAN IN THE VENT ITSELF. VENT HEIGHT WILL BE A MINIMUM OF 6 INCHES ABOVE THE ROOF, OR THE MINIMUM VALUE ALLOWED BY LOCAL BUILDING CODE. MINIMUM CLEARANCE BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE SOLAR MODULE GLASS SHALL BE AT LEAST THE DIAMETER OF THE VENT. IN THE DIRECTION OF THE SLOPE OF THE ROOF, THERE SHALL BE A GAP OF AT LEAST 1/2 INCH BETWEEN MODULES. THE ROOF SLOPE MUST HAVE A MINIMUM INCLINATION OF 10' OR THE PANELS MUST BE SLOPED AT A MINIMUM INCLINATION OF 10'. UPLIFT CALCULATIONS 08.18.2015 ~`o,�SolarCit PV System Structural Version #48.9 •._ , ;;A Desion Software Project Information & Table Of Contents Risk Category: \``? .,, �%SolarC■ �ty MOUNTING SYSTEM:-, ZEP ZS Tile WTile _ 401� PV System Type _ _ 3M p°°^^e" Way Son T: (650) 638-1028, CA 94402 ) 638-1029 (888) -SCI -CITY (765-2489) ww..solarcity.com SolarGty SleekMount- EVERTER Multiple Inverters Spanish Tile Roof Spanish The Roof Layers of Com Roofin- Roof Slope 200 ._ Rafter S adn _ PV System Module Orientation PV Module Area --- - Landscape and Portrait 567 sf _ _ - - _ . PV Module. Width - -- --- - -- 39" ------ PV Module Length Standoff Attachment Hardware SM Tile Reduced _Ground/ Roof Live/Snow Loads Ground Snow Loadpg _— — -- _ _ 0.0 Psf ASCE Table 7-1 Surroundl_ng-Roof $now --_____. ___--- - _ -- __-• _-- ___ 0,0 psf_ -- -- Roof Snow Over PV Modules 0.0 Psf .4-1 Wind'Desi n Criteria Wind Design Code___` ASCE 7-10 Wind,Design Method _ _ _ _ — Partiatly/fully_Fndoaed MP.if10d Basic Wind Speed___ _ _-.__-_ AV- -, -_-- 110 mph �__- _ - - Fig. 26.5-1A� -- --- Exposure Category_ -- _ _Section 26:7 Roof S e _ --_-_C -_- — _ _ Gable Roof Mean,Roof Height_ _ h _ �15 ft_ —_. . Section 26.1_ Effective Wind Area 1 Module A - - _ -- _ _ 17.7 sf _ IBC 1509.7.1 Wind. Pressure.' Calculation Coefficients -_ _. Wind Pressure Exposure Kz 0.85 Table 30.3-1 Topographic Factor _ Section 26.a._ _ . Wind_E iredionallty Factor - Kc! 0.85 Section 26.64. importance Factor I NA Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 psf Equation 30.3-1 Ext. Pressure Coefficient (Up) SCP (Up,)_ -., 0.88 Fig.3o.4-2A/e/c-5A/e ^ Ext. Pressure Coefficient Dw on ,._ G Down _ _-, —_ 0.45 Fg. 30.4 2Wi!C-5A/e Resign Wind Pressure P p_ h GC Equation 30.4-1 Wind Pressure Up _____.P(9A)—— Wind Pressure Down down 16.0 psf Allowable Standoff Spacings X -Direction Y-DFrec ion MaxAllowableStandoff Spacing Landscape 72" 39" Max Allowable_Canti_lever _Landscape _ 24" _ NA Standoff Configuration Landsca e_ Not-Sta gered Max Standoff TrlbutaryArea �� _ Trib 19 sf 3 psf PV As rnbly_Dead Load W -PV__ _ Net Wind _Uplift dt Standoff T -actual 44_6 lbs Uplift Capacity of Standoff T -allow__ Standoff Demand Ca -DCR — _, 43.9% Max Allowable Standoff Spadng Portrait 48" 65" Max Allowable Cantilever -__ �Pbrtit� _ 14�. NA Standoff Configuration Portrait Not -Staggered MaxStandoff Tribulary_Area 3 psf PV Assembly Dead Load_ W -PV Net Wind Uplift at,Stand6if W _ T4aui[ _ Uplift Capadty of Standoff T -allow 446 lbs m Standoff Demand Ca a --.-.- _ - . DCR _--_ 49.195 CONFIDENTIAL - THE INFORMATION HERON CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9223980 0 0 PREMISE OWNER DESMPTION: LOPEZ BARBA, CARLOS LOPEZ BARBA RESIDENCE 51100 AVENIDA VELASCO 8.48 KW PV ARRAY LA QUINTA CA 92253 PAGE NAME (760) 574-6321 UPLIFT CALCULATIONS DESIM Mark Williams \``? .,, �%SolarC■ �ty MOUNTING SYSTEM:-, ZEP ZS Tile WTile _ 401� MODULES: (32) KYOCERA # KU2656ZPA 3M p°°^^e" Way Son T: (650) 638-1028, CA 94402 ) 638-1029 (888) -SCI -CITY (765-2489) ww..solarcity.com S SH' RE.. DATE: PV 4 8/18/2015 EVERTER Multiple Inverters � art � - • Additional highlights: RS=485 communication interface.. ■ ' (for connection to laptop or data ■ ■ • .logger).- PVI-5000/6000-TL-OUTD - Integrated Arc Fault Detection and Interruption (-A Version). Y '- �',� s-« .;� .. to• kW r - a,. is IT + r• n=x..^a"'a LS w. ','44. N•__..`x- s. - _- • .' _ -.i, 4 ' ,: is ..: .. _ _ `' - •r. ~ y . • '•.r '' " :s. .i 1l '• ..• �t - _ w � r "'t - - . ! a i {reY • ti ., . ,- ^ ' � - + 'r r+�• .',4�'. ' -' � r � ..41y r i• t *, . ' 4 - : f'- :ta - � » �� i , - ` ... .rr - { • , -.r 11_.5C •• - - •�,, - - _ • - -, .� F ` ±:. . , r.. ' `+��t f . � r .+ ��` ��. a s . S ,Y,. ., r t _ � - t [3c - •• t r - r 3 _ 7.. .•i^ _ ., 41- r, -Technical data and types ✓ - { A P*+ i, ... • ' ,` � v - 1- - - ,' ^ �, - -• - . ,. 3 _ _ � + , r . . • 3 ., Type code _ �• ? ` - - - - _ v , PVI 50 D US PVI 60 D US OUT— 00 OUT - . • * AU' �� INPut side.— ----- -put r •_• — - - — --00 - - - --- I • �. '• , ��: - -* t ,,.'-4?ra- ,t - i •' _ Nominal. output .............. • 4.......... r ' 5000W z 6000W r . .. .. .. ............. ........... - - .,. .. • ; - - ,, .. -power •a Maximum out ut ower •- 5000W • y- - 6000W. - - 7. ,. ' ' ' •".. i Rated grfd AC voltage = 208V .a 240V. ' 277V 208V 240V .^ 277V , • - In ut side DC Number independent MPPT - r 2 _ , ,`•, r, w- e of channels k o - •• _••. -,•.. t - Maximum usable ower for each channel p......... .................. 4000W .. z _ ►� r .. , ' *= '[ Y } Absolute maximum valla a max) . ... ". 600V, -- �' +' .. _... Start -u volts e start + A - ;. ............................................................... -..................... 200V ed'. 120-350 r ' ...`.. ..i.. ...)................-.............................................................. r - . , s . » •' , . a w r MPPT v ran ' - ull po a oltage a ge -200 - 530 v - • - r . - . ;: - • ` �; _ O eratin MPPT valla a ran a Maximum current Idcmax) for both MPPT in arallel.............::..............._F .... 0.7 x Vstart - 580V - : ............0........ ............... ..............36A................................................................I.......................... .. .c• - ..- �y :. _ :_ Maximum. usable .current per.channel. ........... .... ... ................................................. ......................................................................................................... r .. • - "• t - '_ "`'" °. •'.-_ ^' +. _ _ ` -Number of wire landin terminals pe............................................... channel .............................. . • 2 Pairs i ................. a , - .•„ _ .3. d . .. , a •� - ..r ................................... .. .. ................................. Array wiring termination .......... ......................... _ - Terminal block, pressure clamp, AWGI6-AVJG6 - _ ,.. • - 1..,. ; - 1Output side (AC) - • ' w ` • • _' 3 I " .. c Grid connection type__........: ;. Ad'ustable valla e ran e mrn-Vmax) 10/2W Split. 0/3W 10/2W 10/2W Split-0/3W....i_.._• .1012W 183V -228V i 221 V -264V [ 244V -304V i 183V 228V 217 V 2fi4V 244V -304V zr `z `' `• rF . ey t = '� " . + - Gr cl frequency ..:.......:...:.................._...........J......... ......... ............ Adjustable rid fre .enc ran a •r 60Hz ............... ............ ........... ................. 1 .. ..................................................................................... ....:.......::.........:............. - - 57-60.5Hz . . v • f. - t . - * Highlights. . Maximum current I� A (. .^,°.) " -• - .. ........................ ..............{UnS..................................... . ' Power tactor:i 27 23 20 - 30 28 24 ........... ....,....... Ar., ....,....... 'iw A[u, Ane. Ae„ ... _s ......... s.........i................... 5.......:.:.:................. 5.........i.................. s.:.......i.................. 5.......... > 0.995 -�.. I. i. r ' "F' Designed for residential and small The wide Input voltage range , - ......:..:.:...................:Lt..........._`_'.............'....i........ - Totafn3rmo t..............ortion at rated ower ...!............ ..... ......... ........................ .............................. s- w. -- is»...: <zs. - C 1 d PV this ', makeS.the Inverter suitable tO low _ Single and split output::36.25A t P.........................................................:................................................................:.................................... .[ , 36.5A : :-31.75A 36.25 Apkr..•....z..36.5 Apk�......} 31.75 Apk/ J L commercial Installations, _, ower Installations with reduced p e, phase phase Contributory fault current' ..............................................:...........................................:..........:..................................1:.._2s.s3°nms.....i...:_25.81.... °,/ °Y/ oY/` z .....'...._22;45Aus...:.i...._25.63! es.....i....:25;81,!\nns..........22:45Awns..:... •; inverter fills a specific niche m the string size. g grid connection. _ Grid wiring termination type _ Terminal block, pressure clamp, AWG14-AWG4 - ABB product line to cater for those • -. - Wide input range for increased llnput = Installations producing between , The transformerless operation offers. stringing flexibility. Reverse olarit rotection A..........%..P.....,................. Yes ... ........... - ' - 5kW and 20kW. _ -. _ high performance efficiencies of u to 9 P _... p ' _. --'The hi h s eed and precise MPPT g p p - '! Over -volts a rotecLon ty e: • : - - '� =- g....p..........................e.................................................................................a . - ., - - { Varistor, 2 for each channel - ► . ........ ............. Pre Riso -• * 97:1%. :, PV arra round fault detection ' start -u and Dynamic GFDl re uires-floatin arrays) r ,- .. i .,_ f y ,algorithm offers real time power ,. .•. - output , ,. `• _ _ This Inverter Includes dual input Free remote monitorin ca abili g p tY a -, n im r v n r rts tracking a d p o ed e e gy : 'Anti-islandin rotection g..P............................. ......... Meets UL 1741/IEEE154Zrequirements - ...Meets UL 1741/IEEE1547 requirements . section to process two strings with available with eve Installation. This ' . every harvesting. . Over -volts a rotection?XP..e.......................................................................i........ • • -'g- p - • Varistor,_2..!.. _I z / L...:_Gl............'...........i......... Varistor,_2-(<1.._I / L_: G)..........................' . _ ; < enables homeowners to view their Maximum AC OCPD Rating a u 35A 30A . 25A 40A 35A 30A ` = a independent MPPT. • , energy offers installers x - Outdoor NEMA 4X rated enclosure ,, IEfficiency _ =' -• I •- - ' The high speed and precise MPPT production'and for: unrestricted use under an Y Maximum efficient ..............T...................y.......................... ........... , 97.1% .. ... ...... .. - .... .. .. . .. - offers real Ume power r tive and economic way Of a oat p Y ..- - .. - rlvir nm nt I conditions. ns. r e o e a d O •� CEC efficient �- - , s - .....cy.............................................. ... ...... 9fi% ........... 96:5% 96_:59'0. 96% 96.59'.. 96.59'0... .^ •--Graphic display••• - - ' ,,algorithm tracking and energyharvestiri ', 9_ 9• - maintainingand troubleshootingthe •_- , -. . , _ h Integrated DC disconnect switc , User interface z (Operating performance *�i-" Graphic display _ .. ` ., FIefficiencyurves ensure high atc 9 ,.rsystem: _ : in tom liance with international p .Stand -b consum tion Y.... p.................................................................................. _ , —, <8w'- - ............................... z...........................................,............................................. .. aMs ........ efficiency at all output levels ensuring y ,, y Standards (-S Version ' : ) Ation = ; ' Niarit time cons _ <0.6W <0 6W°,.� .. consistent and stable performance �• 4 ' , : = - icommunicationum User -interface 16 characters x 2 lines LCD display ... .................... .......... • f , - .- across the entire input voltage and P 9 „ . , _ • .,.' .. '. _ , ...Remote rnoni[orfn......1xRS485 incl.j.._........ .:......... ( ' ' g ..................................... ..................... _ ....... ................. ..... . ...;..tVSN700 Data Lo q!p!. qp.! .. .................... ............ g.9...........P...)...................:....................................................... , •PVI-USB-RS485_232 output power range. �� +'• Wired local monitoring (1xRS485 incl.) (opt.) —T ' _'designed This outdoor inverter has been z �• �• _ [ lEnvironmental Ambient air operating temperature range -13°F to +140°F (-25°C to +60°C) with 13°F to +140°F (-25°C to +60 C) _. desi ned as a tom letel sealed unit to 9 p Y _ [ ....................................... -e ....:. ............. .................... to withstandthe harshest environmental — Arnbieni air stars tem erature ran a g............_p........................_g.......................................................... -40'F to +176°F -40°C to +80°C -40°F +176'F -40°C to +80°C) I......................................_..............................................................(................................................... Relative humidity................................................................_: .,. t............................g 0 700% RH condensin.._'................'.i...................:._0, 100% RH condensin conditions. I\ I! 1! Acoustic noise emission level Maximum o eratin altitutde without deratin < 50 db A ®tin < 50 db (A) ®im .... ...... _ - 6560 ft 2000 m) 6560 it (2000 m) r _ _ . Power and roductivlt p - Y 0%191P . ,.............................P.............g.....................................................-g................................................................................._(......................_.:...........:_.....F 2. Inverter can aDPN that much current - Breaker vriil open -* - . r - for a better world'" 2 ABB Solar Inverters I Product flyer for PVI-5000/6000-TL-OUTD - li"SolarCity I ®pSolar Next -Level PV Mounting Technology .Zep System for tile roofs using replacement tiles UL LISTED ETI zepsolar.com L—Ikqwwi ewd—TO amotid TapNm at01f/w m. rr " AraiaoleM-drill �gm>—Mrq I u ♦m>•� or,or —04 .n,o 1lWGlistunp «e raww� anu i Description • PV mounting solution for concrete tile roofs • Works with all Zep Compatible Modules • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules • Auto bonding UL -listed hardware creates structual and electrical bond Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72" and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain This document does not create any express warranty by Zep Solar or about its products or services. Zap Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 12 31 14 ZS for Replacement Tile Applications Culsheet Rev 02.pdf Page: 1 of 2 6olarCity ®pSolar Components Replacement S -Tile Part No. 850-1435 Listed to UL 2703 Next -Level PV Mounting Technology Replacement W -Tile Part No. 850-1437 Listed to UL 2703 Replacement Flat Tile Part No. 850-1436 Listed to UL 2703 Tile Roof Attachment Kit Part No. 850-1434 Listed to UL 2582 f) Ground Zep Part No. 850-1172 Listed to UL 2703 and ETL listed to UL 467 zepsolar.com Interlock Part No. 850-1388 Listed to UL 2703 dt, , Array Skirt, Grip, End Caps Part Nos. 500-0113, 850-1421,850-1460, 850-1467 Listed to UL 2703 Leveling Foot Part No. 850-1397 Listed to UL 2703 DC Wire Clip Part No. 850-1448 Listed UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 12 31 14 ZS for Replacement Tile Applications Cutsheet Rev 02.pdf Page: 2 of 2 - - I 1 ' Label Location: Label Location: Label;Location: - '�- (C)(IC)(CB)(AC) y (DC)(INV)(CB) PV SYSTEMPer Code`. 1 DISCONNECT FOR Per Code: ; CRC R331.2' OPERATION i - • -. - - - Label Location: i ~� _ THE DC CONDUCTORS OF THIS - • • • • - TO BE USED WHEN.UNG' PHOTOVOLTAIC (DC) (INV) s - - -• ' ' • ' INVERTER,IS ` DISCONNECT Per Code: !' - ; UNGROUNDED, e ' CEC 690.14.C.2 f Label Location: Per Code:, WARNINGt' Y • _ Y r' r i ' t ; . ELECTRIC • '. : . > , Label Location: .e • • -. _ �. - T .� - I1, .y CEC 690.17 = = A: w ,' r r MAXIMUM • • - (DC) (INV) ON BOTH . _ ,,, • Per Code: - . • . . - . ' F - t• s ,. -• - ®- -• a r. • - -• • CEC 690.53° VOLTAGE (Voc) SCUR HORT-CIRCUIT= Label Location: (POI) 1 Per.Code: z Y t Y K 'INVERTER• CONNECTION- CEC 705.12.D.7 _ Label' Location: . • NOT RELOCATE. ; ' f• - r WARNING(DC) (CB) r •. Per Code: - . • •TOUCHEVICE ELECTRICAL • -. TERMINALS CEC 690.17 _LOAD SIDES MAY BE ENERGIZED TERMINALS ON BOTH LINE AND IN THE OPEN POSITION Label Location" - - i • . �: VOLTAGEDC PHOTOVOLTAIC POINT OF (POI)ALWAYS PRESENT WHEN INTERCONNECTION t• r • - Y' t' , Per Code:SOLAR EXPOSED •• • • -D. • SHOCKULES ARE WARNING: ELECTRIC CEC 690.54; CEC 690.17 � F _ • . TERMINALS - BOTH THE LINEAND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE Label Location:.E -ENERGIZE BOTH SOURCEWA f 1 t 'Y,y •• �r r F (INV)PV RNING -•• BREAKER.IN •t - _ ,.• _ ELECTRIC Per Code: MAXIMUMAC 11' • . - . OPERATING CURRENT IF A GROUND FAULT IS INDICATED CEC 690.5(C) MAXIMUM AC NORMALLY GROUNDED OPERATING VOLTAGE CONDUCTORS MAY BE A UNGROUNDED AND ENERGIZED . — s «' _ _ ` ... . ;' " - ' r � .. "+ f. ".t . �� x • d _ `+ r• � } ,!'y !y, a .. i Label Location: •, r ,- ' _ - Label Location:CAUTION (D) (POI)PHOTOVOLTAICr- (AC) (POI) PHOTOVOLTAIC SYSTEPer Code: . • 4 • ..�� (AC): AC Disconnect _ • Per Code: - _ . CEC 690.64.B.4 _ . _ . (C): Conduit DISCCEC 690.14.C.2(CB): Combiner Box , i T t (D): Distribution Panel (DC): DC'Disconnect. • - - a - - t - • ' - _ _ (IC): Interior Run Conduit ` Label Location: Label Location: (INV): Inverter With Integrated DC Disconnect' ' MAXIMUM AC A (AC) (POI)CAUTION (POI) (LC): Load Center OPERATING CURRENT Per Code:, DUAL POWER • Per Code: (M): Utility Meter i • - •MAXIMUM AC CEC 690.54 SECOND PHOTOVOLTAIC •URCE IS CEC 705.12.D.7 - _ (POI): Point of Interconnection - I r = r 'CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED- FOR _ 3055 Clearview way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED ►-..y San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, • Label Set T:(650) 638-1028 F:(650) 638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE'OF THE RESPECTIVE _ /� (888) -SOL -CITY (765-2489) www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. i SOI` 3 ' ' o CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 51100 Avenida Velasco UTILITY SERVICE INVERTER AND DC DISCONNECT INVERTER AND DC DISCONNECT AC DISCONNECT r— — — — — — — — — — — — — -- — — — — — — —— — SOLAR PHOTOVOLTAIC ARRAYS) L--------------------------J PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB -9223980-00 m CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION HATH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER— rnuex umm: unxaarnuw: LOPEZ BARBA, CARLOS LOPEZ BARBA RESIDENCE 51100 AVENIDA VELASCO 8.48 KW PV ARRAY LA QUINTAr CA 92253 PAGE NAME: (760) 574-6321 SITE PLAN PLACARD uWlbr: Mark Williams A'j'solarCity. MOUNTING SYSTEM: ZEP ZS Tile W file I y- ' MODULES (32) KYOCERA # KU2656ZPA 3055 CleaMew Way San Mateo, CA 94402 638-1028 F:(650) 638-1029 (BBB) -SOL -CITY (765-2489) www.edarcity.com SHEET: REV: DATE: PV 7 8/18/2015 INVERTER:T:(650) -Multiple Inverters i .. ' Solar inverters Additional highlights: , - RS -485 communication interface _(for connection to laptop or data strii logger).'_., +• . . ` Integrated Arc Fault Detection and m t: =(.. • Interruption (-A Version). . .r� h J,, • .• S. r • , .f r` - k Technical data and types r" Type pe code - .._ PVI -3.6 -OUT -D --U-S P-VI3.8-O- - -- - 4.2-OUTDS-.- � A$ , y + IMechanical specifications • 7 3300- c W 3600W W 4200W - Nominal tut w r 3000 3800 • � � • f •`" • +r . � - ,, r ,, , -output power . •'Y' i 1-: yy , ..:........................................ ...............:._'..r....... r.... 000 '.3300' 33001 3600 1 40001: 4000' 3300. 4200' 4200' .4200 `. 4e00 :4600 d e Maximum out ut flower watt.. e 3 P p 9 �. ,+ ..... . ... - • 't - . - W- VV' W W W W W W W W VV W ' ' • 1 _ . > Rated grid AC voltage 208V i • 240V '€- 277V 208V 240V ' 277V 208V 240V 277V. 208V 240V 277V • •,. ° + ' • ' ♦ � u I Input side (DC) Numberoi..ride endent MPPTchannels 2 2 2 2 I . w P . .................... ............. _ .... ........... ... ........... » y,. a +y W 3000W _ 3000W a 3000W I Maximum usable ower for each channel 2000 3.....` ' 1 Absolute maximum voila a max -� +; ' 600V : + + ' Start-up voltage (Vstart) - r + r 200V (adj. 120-350V) . _ r ......... ............................................................. P ` :: {, ; » FuII ower MPPT Volta elran e......` 160-530V 120-530V 140-530V. 140-530V - r .... ........ .� - >'.... , +. .. i . 1•" ......g.............g...................:. - ....................... ..... ..................... ........ ............. ......I....... ...... At > - ` " '°Y . '' • .• - " ; i 0 eretri MPPT volt.. a ran a 0.7 x Vslarr- 580V >=90V) i... ....$... e P..............9............................g..........._g...............:.:....,........i.............:......:..._......(.................................................................................................._ • s -' s �' Maximum current (ldcmax)-for both MPPT' 1n, a 32A? 2 A.... .. 32A 32A s - - .....ilei • '> .t :^-.+ i . - _ t _ . w n I' .1 A 1 A 16A - 16A - - '. • - Maximum usable_current.P.er c....._`.. ............................................_6 ..................... _................................ ..... Maximi n short circuit current limit per , Ar A ' s 12.5 20.OA . 20.0 'MOA . - channel ......................................................... .................. ........................................................... .......... .... w... . .......Y.._ r in I r h nn 12 airs s. ' • Number of wire landing. t....!..?....a S.P.e...q._a...._e....:........... ................... P..............................................................:.....:.:...:..............:.":.........................._ 04 Arra wiring termination tr Terminal block, pressure clam AWG10-AWG4 (Output side (AC) - ♦ +_ „•. ,,,. - + t - - .. ♦ € 10T-Sph1 70T•�^ Spit 10/ 10/ i Split- 10/ 10 Spi—p 10% i 3 r a Grid connection9ype t 2W i.0/3W i 2W 2W i 0/3W ? 2W 2W 0/3W. ': 2W i 2W i 0/3W i ,•• 2W... ` - t........................................................ ......................... .? _ _ ` r• - _ ..._7.83._,.......21.1.........._244_.........183 -......._21.1_........244-.1.:_..183_......._211 244-:........183_........_211_...... a • - tr w T R Y », _ , . + fi - , .. , - _ < a + et. •� +..�' , - b_...AG...d.r..).u..-.s....e...9.u...........Y.............:......:..........r........._ • .... ....... 244- Adustable voltage range (Vmin-Vmax) V.. -j - ,228V 264V 304V 228V 264V 304V. 228V V 304V 228V 264V304V idtr...enc... ...:.......................... ......... .. .... ... ........ ....................................... ............ ....... ................................ 60Hz table 57-60.5Hzr- - , . • - t • «: r-• (I ) a . .. - ....... ....1..... 6Z ....................... :..20,..20.0, 14.6..120.(7.21160160 0200 Maximum current ' ................. - ._Aa _ 'P`ems....E.....Sans.........Aawrs....t.....Aarns....i....Aa.s....i..._Awµs....E..._Anes....i.....Aarns_..i.....AaxtS....i...:.!�srns....E...:.nlws-:.. s .. . ,- r + �: r r <- > ^. _ ♦ Power factor... v ............................................... > 0.995. { }. r ................................................ ................. ............................ u -If . Total harmonic distortion at rated ower v :-........- .............r+.. a < 2% This family of single-phase string The high-speed MPPT. offers real- _ ._.Highlights: _ -' r, Grid wiring termination type - _ Terminal block Pressure clamp, AWG10-AWG4 ' » - Input protection devices ' = inverters complements the typical time power tracking and improved - Single phase and split phase output ; �- ll P P - Reverse olarity rotection ...... .... ....... ..... Yes ... .. ......... ......... ........ • ' number of rooftop solar panels energy harvesting. grid connection. • - ` _ . - Over-volta.4e..P..!Rtection tY..P..e.....`:......--'...................... : . Varistor...2 for each, channel .... • enabling horne-owners to get the most The flat efficiency curve ensures high. -,Wide input range for increased PV array ground faun detection Pre startup Riso and Dynamic GFDI (requires floating arrays) r ices 1 ` ` efficient energy harvesting for the size + efficiency at, all output levels allow(Output protection devices ing ` stringing flexibility. ♦., ,' - -:r - -.. �? 1, Anti-islandin rotection Meets UL 1741/IEEE1547 requirements ' PPT g..p................................................................................................ of the property. a consistent and stable performance - The high speed and precise M ---......... Over -voila a rotectiont e . Varistor,2 ....Lz�L G } . g.....P.........................Y..P............................................;...................,.........'...;..'....r."...,:......................(!..:.........._!.....)............:...................:...................,................:......:........ across the entire Input voltage and, algorithm offers real time.power _�. . • Maximum AC OCPD Rating 20A„ ' 20A°, : 155.. : 25Ao,•'. 20Ai 20A°,°: 20A° 20Pe °: 20Ao ° 25A, 25Pb„ i 25A°„° -' This inverter offers a dual input ' output p'owefrange.' t,• , ,tracking and improved energy IEfrdiency _ __ _ 1 ' • .. - * Maximum efficient 96.9% '97% .97%:- ......... .97% ` section that processes two strings The transformerless operation gives the harvesting.-....................................Y............................................................... .............. CEC efficiency- 96% • _ with independent Multiple Power Point highest efficiency of up to 97.0%. - Outdoor NEMA 4X rated enclosure ' ... : , + lOperating peormance ' Tracking (MPPT)._,The wide input voltage range makes; _ for unrestricted use under any " Night time consumption <0.6W • , This is especially useful for rooftop the inverter suitable to low power environmental conditions.. Stand-by con tion - < 8w f _ ' Communication installations with two different. installations with reduced string size. Integrated DC disconnect switch User -interface .............................................. 16 characters x 2 lines LCD display ........................................................ ' k........................................ ... .. ........ orientations from two sub -arrays This rugged outdoor inverter, has been in compliance with international `- Remote monitoring (1xRS485 incl.) VSN700 Data Logger (opt.) N oriented in different directions. (For designed to be a completely sealed Standards (-S Version). ' I? Environmental nt air.q _ € Ambient ..... operating temperature range ..............1.............. ! -13°F to +140°F with derating above 122°F (50°C) ..................... ` example: East and West unit able to withstand the harshest i Ambient air stora a tem erature ran a 40 F to +176 F 40 C to +80 C g P........ 9................::................................................................................................. (....... )....... The dual Input sections with environmental conditions. .Relative humiditY...,.....:..............................................................................'............:........:............................. 0-100%'RH concien ...................... Acoustic noise emission level < 50 ............... b (A) ........ 1 m ..................................................... Independent MPPT enable a more ......................................... ...................................................... :..........................................................................._..'........................................................ .... + Maximum o eratin attitutde without derat' 6560 ft 2000 m P...............g.......................... g......................................:......................................:................:........................5...................................................................................................................... .optimal energy harvesting condition. P N D !Capabilityy at nominal AC voltage antl with suffcient DC power available. ; Power and productivity „ IND. 1. enabletl . ? ' for a better world AM IP 19•'. - - - . , - • - . - �- 2 A88 Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-01JTD , n ` • + -' • j - _ CUTTING EDGE TECHNOLOGY As a pioneer with four decades of experience in the development of photovoltaic systems, Kyocera drives the market as a leading provider of PV products. We demonstrate our Kaizen philosophy, or commitment to continuous improvement, by setting the industry standard in the innovation of best -in -class solar energy equipment. QUALITY BUILT IN • UV -stabilized, anodized aluminum frame in black • Supported by major mounting structure manufacturers • Easily accessible grounding points on all four corners for fast installation • Proven junction box technology with 12 AWG PV wire works with transformerless inverters • Amphenol H4-UTX locking plug-in connectors provide safe, quick connections PROVEN RELIABILITY • Kyocera modules confirmed by the Desert Knowledge Australia Solar Centre to have the highest average output of any crystalline module • First module manufacturer in the world to pass long- term sequential testing performed by TOV Rheinland • Only module manufacturer to achieve the rank of "Performance Leader" in all six categories of GTM Research's 2014 PV Module Reliability Scorecard CERTIFICATIONS • UL1703 Certified and Registered, UL Module Fire Performance: Type 2, CEC • NEC 2008 Compliant, IEC 6121561730, and ISO 14001 QC'�MPAt,6 H / ' C UL US O ~�p°onlvOP, KU -60 1000V Z Series KU Z 65-6ZPA KU -60 1000V Series ELECTRICAL SPECIFICATIONS MODULE CHARACTERISTICS Standard Test Conditions (STC) Cells per module: 60 (6 x 10) 0 Dimensions: 65.43ini38.98ini 1.57in length/width height (1662mm/990mm/40mm) Weight 45.2lbs (20.5kg) Plrra< 265 W V1°P 31.0 v PACKAGING SPECIFICATIONS LIP8.55 A ] Modules per pallet 20 Va 38.3 V Pallets per 53' container. 36 Pallet box dimensions: 66in/40ini43in lu 9 26 A length/width height (1675mmi 1 005mm/ 1055mm) Ptam°.• +5/-0 % Pallet box weight 1015lbs (460kg) NominalOperating Cell TemperatUre Conditions• NOCT=800 WIMlirrodionce,1. 57' TN� 45 °C 1— - -- -- � ED POTTuA9 P JUNCTION 1 91 W nP°5) i V7 27 9 V _ _ _ —_-._ _--_ -- __ _.___ - CABLE O Imp 6.85 A CONNECTOR + LABEL V 351 V 1111 - --- -- - -- - ---- -- - ---- — - - - - - - � � 7.49 A ! PTC 238.1 W remperature Coefficients P 0.45 %/°C 1. to z V rp -0.48 %I°C p 0.02 %I°C V. -0.36 %1-C 38.98" (990mn) I 0.06 %�°C Operating Temp 40 to +90 °C 67-°°ndlnR Hole sl°tted Rmmtlns Hole 0.16- (es0 0.35-.0.47- (wo.lbra) System Design FRAME CROSS SECTION DIAGRAM Series Fuse Rating 15A n0.41A>v Maximum DC System Voltage (UL) 1000 v G Hailstone Impactin (25mm) @ 51 m (23m/s)l - 1.>8"os.0 'Subject to simulator measurement uncertainty of +l- 3%. KYOCERA reserves the right to modify these specifications without notice. Lona/SHORT SIDE QWARNING: Read the inslruclion manual in its mnprior to handling, installing g & 8 operat- ing Kyocera Solar modules. 040215 OUR VALUED PARTNER r B .. • >-.7 . 6 5 4 .3 2 1 0 T 0 9.11 (231) ` 7.35 (18]1 8.66 [220] 1 .33 [8] 06.41 C $ w ®^ 1 ® �D C ®, OFF 0 N O • CONCENTOC KKOCKOTS POR' _ TANGENnAL KNOCKOUTS FOR 1/2.3 6 1. 1-1/1 CMIDW 3/1• 1. 1;,/- GONOUT D i o B o I Ir n .13 (111 3 27M8.um NgiS &el A , .e8 1221 . n 7.00 [I]e] - B ' • ' TANGENML KNOCKOUT FOR 1, 1-1 1, I-1/2 CONOUO NOM I 0 I 1. METOL gMEN90N5 (0WI1 WWMEIERS) ARE SHOT W BRACCI�'IS. 2. ME RANGE 0( LUGS 6 1/0-011 COPPER OR ALDMWUM. 1.38 (35] . F] lel SS10W uUff . - .. OWNIItt 1 2.62 [51 ' - • A - 8.10 [213] �. A •' • ae CUTLER -HAMMER it ' m`�� 9e a. a.ENSON SHE Ir-- 80 uIP tt E 3R GENERAL CM ' 59C 4 o 95-1451 ,r r B .. • >-.7 . 6 5 4 .3 2 1 0 T 0 9.11 (231) ` 7.35 (18]1 8.66 [220] 1 .33 [8] 06.41 C $ w ®^ 1 ® �D C ®, OFF 0 N O • CONCENTOC KKOCKOTS POR' _ TANGENnAL KNOCKOUTS FOR 1/2.3 6 1. 1-1/1 CMIDW 3/1• 1. 1;,/- GONOUT D i o B o I Ir .13 (111 3 27M8.um NgiS &el A , .e8 1221 . $ w ®^ 1 ® �D C ®, OFF 0 N O • CONCENTOC KKOCKOTS POR' _ TANGENnAL KNOCKOUTS FOR 1/2.3 6 1. 1-1/1 CMIDW 3/1• 1. 1;,/- GONOUT D i o B o I Ir J .13 (111 3 27M8.um NgiS &el A , .e8 1221 . n 7.00 [I]e] - B ' • ' TANGENML KNOCKOUT FOR 1, 1-1 1, I-1/2 CONOUO NOM I 0 I 1. METOL gMEN90N5 (0WI1 WWMEIERS) ARE SHOT W BRACCI�'IS. 2. ME RANGE 0( LUGS 6 1/0-011 COPPER OR ALDMWUM. 1.38 (35] . F] lel SS10W uUff . - .. OWNIItt 1 2.62 [51 ' - • A - 8.10 [213] �. A •' • ae CUTLER -HAMMER it ' m`�� 9e a. a.ENSON SHE Ir-- 80 uIP tt E 3R GENERAL CM ' 59C 4 o 95-1451 J 0. ®' ZS COMP I GROUNDING AND BONDING Zep So -lar ZepSolar ZS Comp'" I Grounding and Bonding This document describes the mechanics of how the electrical bonding is accomplished between the UL Listed hardware components used in Zep Solar's ZS Comp mounting solution for composition shingle roofs. Zep Compatible- systems do not require running copper conductors to each module. The act of physically installing each component simultaneously establishes an electrical bond, as described in the following pages. Document 800-1478-001 Rev A www.zepsolarcom PAGE: 1 of 5 ® 2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25.20134:45 PM Interlock Interlock Zep .F.�1 r UL Listed to UL 2703 Tongue side Key Side Bonding Cutting 'tooth" Key side in closed position Cutting 'tooth" Tongue Side Bonding Tongue side in closed position Cutting *teeth* Side view Interlock Module Bonding locations on Key side Forced interference during rotation of Interlock Zep causes teeth to cut through anodization on module frame, resulting in robust and UL certified bonding path OModule L Forced interference between mating parts from module Bonding location on rock -in motion cuts into module frame. removing Tongue side anodization and resulting in robust and UL certified bonding path Document 800-1478-001 Rev A www.zepsolar.com PAGE: 2 of 5 ® 2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25,20134:45 PM — A _ ®' ZS COMP I GROUNDING AND BONDING M1 �* • ` 'ZS COMP I GROUNDING AND BONDING - - - Zep,Solar ZepSolar.` t Interlock, continued _ - -Leveling Foot = , • - - Tongue side Keyside b Spring clip - • - ♦ - n - - Part No. 850-1388- 'J UL Listed to UL2703 • "' + �. t r --'M, - ! - t s - _ - A. w - - 'w`' - - .+ ♦ ' • - " - J,+� rxr+_ - r • • Part No. 850-1397 , The Leveling Foot top portion (the Rockit) has a stainless steel' - - - Bonding Path - Key and Tongue --, + w - UL Listed to UL 2703 spring clip that bonds to the adjacent module frame on both The Interlock bonds modules on all sides to create a hyper- " Key and Tongue sides. •• _ - bonded array where every module Is structurally and electrically bonded to the surrounding modules. y • w ;. - L - y Leveling Foot - Bonding With Module Frame • . Module . • I - _ a ?: `r•. ' - ! - .� - �• - ,Tongue side • 'y T •. A-_� _ arc arz r .. ; - .4r 6 _ s Interlock_ o Key side _ 4 t - - - Key side inserts into Zep Groove (rock -in) Module in next row drops in on the Tongue side -Bonding Path - Array' ^ ` ?'r Bonding Path'- Northand South Modules i ♦ , .. - - - '�, - - `'.r - _- . „ •_ i - - - '_ ' .y Bondinglocationon W a w at w : tv •' path g - Bondin •` '.p i - ® Leveling Foot . , • Q _ F' .M - `- - t - o- Interlock'r ' - Ir • - �, -^ - _ c �eKeyside •' path g - Bondin •` '.p ®' ��® - ® Leveling Foot . , • Q _ F' .M - `- - t 3�• r ,. .+ ._. - ,, jIf ' 1 - - !� Av Bonding path .� 5 _' _ s s" rt � ' • - - - . _ � roe Y -.. _ � a .. • 1 _E1 AI • — - - '� R 3 F; a _ Bonding location on s� Module rotation during drop-in forced creates V1\` Down -roof Tongue side interference between Zep Groove and spring clip, .Down -roof - _ '' w cutting into module frame, removing anodization and resulting in robust and UL certified bonding path - Document 800-1478-001 Rev A + www.zepsolar.com Document 800-1478-001 ReyA www.zepsciar.com.� M 71 PAGE: 4of5 PAGE: 305 _ m20131EN Zep Solar,Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rightsreserved. ` 02013fEN Zep Solar.Inc.2ep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. _ . _ Date Last Exported: June 25, 2013 4:45 PM - ' - _ Date Last Exported: June 25,2013 4:45 PM ®. ZepSolar ZS COMP I GROUNDING AND BONDING Ground Zep Setscrew Part No. 850-1172 UL Listed to UL 467 and UL 2703 Ground Zep Installation Key side Ground wire channel The Ground Zep provides a single point of connection for the Equipment Grounding Conductor (EGC) from the array to a building ground. o C©7 211A Insert Ground Zep into Zep Groove of module frame, Use the Flat Too to rotate the Ground Zep 90 degrees. so that set screw Insert copper EGC into ground wire on array perimeter is pointing straight up. channel. Tighten set screw using torque values shown in the ZS Comp Installa- tion Manual. Bonding Path - Array to Ground *> Ground Zep Equipment Ground Conductor Bonding path I Down -roof Document 800-1478-001 Rev A www.zepsolaceoni 02013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. PAGE: 505 Date Last Exported: June 25,20134:45 PM ,d 4, s_. NOTICE OF COMPLETION o�r` AND' F r AUTHORIZATION TO APPLY THE.UL MARK, S _ k d • r __ 12/21 /2013 5 a` - =The SOIarClty Standard Box 4:1 is a Manufactured to meet UL 1741 Standards.. Solarcity Corp 4 -String unfused Junction Box. The box . Non -Metallic, Corrosion Resistant NEMA 4X Enclosure. Alex Yang•. .4-String highly configurable and adaptable 3055 Clearview way •Factory -Installed Cordgrip Enhances Installation Speed. San Mateo Ca 94402-3709, Us _ K using the (4) jumper blocks included in. ,• „ ? each box. A factory installed cordgrips Break-Thru Skinned -Over. Glands on Cordgrip Provide- ±� w111011, r 4 z tI I• ti enhances installer. productivity" Weathertight Seal for. All Configurations. - Our Reference: E31t3537,�Volume 1 `yr•� ,"Protect Numbers 4786083586 - Your Reference: ,L A.Ya � 0/7 + - ! Easily Configurable Terminal Blocks Permit Adaptation ; -� 9 !.' •— ;} "� 3a"� ir. a Project Scope: Inveshgatiori of. Photovoltaic (PV). System Combiner Box, model .Solarcity Standard Box 4C" to Site -Specific Stringing Needs. ' t_ ;and Photovoltaic (PV) System Transition Boz, modet"Sola'rCity Standard•B{ox 4J" to UL 174.1 ` . a' - i - - - } --r - ri! i ''Standard: p•`". • • -., r•i1• .:, "(,- - + _ Dear AlexYang3^ 1 Nfii'r' * + -^ Congratulations!; UC's investigation ofyour product(s),has•teen completed under the above nce Numtier and r ;• Technical Data /,Specifications the roduct was determined to comply,' with thea iicablia �e uirements. Th lettertem temporarily su Iements;tlie UL F_ PP q P Y pp. -- - �� ! Follow -Up Services Procedure and serves as authoriiation4to apply the UL Marc at authorized factories;under UL's ` - .. 0 Voltage Rating [VDC] : 600V, Follow-Up,Seri ice Program. To provide your manufacturer(s) with the intended authorization to use th"e ULr,Mark;`k� - _ — { you must send a copy of this notice to each manufacturing location currently authorized under E318537{,Volume 1 •. © Maximum DC Current [A]: 57A . - and including any special instructionras indicatedrn the addendum'td tHii.1etter: j ' r� ;� Maximum Continuous Current [A]: 42A Records.in the Follow -Up Serylces Procedure cowering the product are now being prepared and will be sent 1.m the = , r near future!' Until then, this letteF authorizes application, of the ULlMark for 90 days from the date indicated above - - ©D •Maximum Voltage [VDC]: 600V + . • . - - - .'r - - - _ r.. c j.,., a �t 1 - ,ids - ,� l - x,:' • ' . ` Wire Size Range [AWG]: #6 to #14 • T, Additional requirements related to your responsibilities as the Applicant can be found in the document "Applicant ' r ,• . responsibilities related to Early Authorizations"that can 6e found at the following web -site: �^ • w. _ _ - OF Enclosure Rating: NEMA 4X + t/www I:i om/E�AReso, on_slbilities. .1 ..4 Z Operating Temperature erature Ran e C 40 to 50 :' ] ' An information and documentation provided to you involvingUL. Mark services are provided on behalf of UL LLC- (UL) or any authorized licensee of UL- i 7ifeA►+?•' H Typical Overall Dimensions in 87x6"x4"16 We are excited you are now able to apply the UL Mark to your products and appreciate your business. ,Feel free to , . « r contectme &,any of our Customer Service representatives if you have any questions.wq Very truly.yours, } . Reviewed Jon AdonaY l William R Carney r A . - ' 408-754-66304% • ` ,�. , 847/664-1088 Engineering Assoaate'Lead., = Chief Engineer Director,I t Jon:Adonay@ul.com `s o _ Wiilliam.R.Camey@ul.c_om « - :. 1 �_ - ; _ .,. f • .. • + -. . .� ' ~�-.1 'ice J'• .y` .: ���4j� :^�A � .. NBKD9C5-90BA67 Solarcity® October 2013 ` This is an electronically generated letter,: Signatures are not required for this document to be valid.- Page 1 of t • ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A" AMPERE' 1. THIS SYSTEM IS GRID-INTERTIED VIA A ALL CONSTRUCTION SHAbL COMPLY WITH THE 2013 AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. CALIFORNIA- BUILDING, R IDENTIAL, MECHANICAL, BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. ELECTRICAL, PLUMBING,: NERGY, AND GREEN CONIC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTINGBUILDING CODES AND TH _ LA QUINTA MUNICIPAL DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN CODE EGC 'EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. Y, r (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING' EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF-THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I - :CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B)..S- Isc SHORT CIRCUIT CURRENT- 7. DC CONDUCTORS EITHER DO NOT ENTER ' kVA KILOVOLT AMPERE BUILDING OR ARE' RUN IN METALLIC RACEWAYS OR C/T y j kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD' BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). AP MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN �`j P .� (N) NEW - RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY O/� COR®��, DF�p/. d NEUT NEUTRAL UL LISTING. NSTw NTS NOT TO SCALE . 9. MODULE FRAMES SHALL BE GROUNDED AT THE - i D47- RUC'/ �- OC ON• CENTER ' r UL-LISTED LOCATION PROVIDED BY THE ! By 0/V PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING L POI POINT OF INTERCONNECTION HARDWARE. - ' PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, ANDDkOSTS SHALL BE �. SCH SCHEDULE BONDED WITH EQUIP G CONDUCTORS. S STAINLESS STEEL �000/// , • - \� STC STANDARD TESTING CONDITIONS, ct TYP TYPICAL . 44 UPS UNINTERRUPTIBLE POWER SUPPLY 1 2015 i • ' V VOLT_, AUG. Vmp VOLTAGE AT MAX POWER ;, uINTA VICINITY MAP- - INDEX Voc VOLTAGE AT OPEN CIRCUIT OFt\je\_0p'tA0A W WATT CIV:: • ', - -� r - 3R NEMA 3R, RAINTIGHT . COMM M • ` • . , PV1 COVER SHEET _ PV2 SITE PLAN PV3 STRUCTURAL VIEWS - PV4 UPLIFT CALCULATIONS ' LICENSE GENERALNOTESCALCULATIONS PV6 ELECTRICAL CA CULATIONS - " . CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 Cutsheets Attached C-10 CALIFORNIA BUILDING CODE AND' THE 2013 CALIFORNIA RESIDENTIAL CODE. N 2. ALL ELECTRICAL WORK SHALL COMPLY WITH F F: THE 2011 NATIONAL ELECTRIC CODE AS-AMENDED BY ?� _ 1THE 2013 CALIFORNIA'ELECTRIC CODE. ` • .,� w MODULE GROUNDING METHOD: ZEP SOLAR 'i, ' '' "' '� •• - - - Q) REV BY DATE COMMENTS 1 AHJ: La QUlnta REV A NAME DATE COMMENTS �y 'UTILITY: Imperial Irrigation District CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER --9223980 J B0 0 PREMISE OWNER: DESCRIPTION: DESIGN: • - `\ / -� CONTAINED SHALL NOT BE USED FOR THE LOPEZ' BARBA, CARLOS LOPEZ BARBA RESIDENCE Mark"wlliams� �501a"rC�tyBENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP- ZS Tile WTile 51100 AVENIDA VELASCO 8.48 'KW PV ARRAY. ,_ PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES LA QUINTA CA 92253 ORGANIZATION, EXCEPT IN CONNECTION WITH " Way THE SALE AND USE OF THE RESPECTIVE (32) KYOCERA # KU2656ZPA on M t eorvA 440 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE. ' Son Mateo, CA' 50) 6 PERMISSION OF SOLARCITY.INC. (76O 574-.6321 PV 1 8/18/2015 (868) `SOL (868)—SOL—CITY 2489) wlww da�Oiycom Multi le `Inverters \ ) COVER SHEET