04-5968 (SFD)e ^� BUILDING & SAFETY DEPARTMENT P.O. Box 1504 _ (760).777-7012 78-495 .CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number . . . ... 04-000'05968 Date 8/30/04 Property Address . . . . . .. 51220 AVENIDA VELASCO APN: 773-065-010-10 -000000- Application description . . . DWELLING - SINGLE FAMILY DETACHED Property Zoning . . . . . ... COVE RESIDENTIAL Application valuation . . . . 117337 Owner Contractor MARK TU_VELL MTB INC. 50-855 WASHINGTON ST. #149 50855 WASHINGTON ST STE 149 LA QUINTA CA 92253 LA QUINTA CA 92253- 2253(760) (760)272-6044 WCC: STATE FUND WC: - 1795095-2004 08/01/05 CSLB: 838089 05/31/06 CCC: B -------------------------- Structure Information --------------=----------- Construction Type '. . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Flood Zone . . . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 667.00 PATIO SQ FTG .12.00 NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- ,FI,RST FLOOR SQ FTG 1820.00 Permit . . . . . BUILDING PERMIT Additional desc Permit Fee ,702:50 Plan Check Fee 456.63 Issue'Date Valuation . . . . 117337 Qty Unit Charge Per Extension BASE FEE 639.50 18.00' 3.5000 THOU BLDG 100,001-500,000 63.00 Permit . . . MECHANICAL Additional desc ..Permit Fee. 59.00 Plan Check Fee 14.75 Issue Date Valuation 0 Qty Unit Charge Per �_--e n Extiiqj'j Sion ocT o 12004 ' v IfyTA I A bE T: "E P.O. BOX 1504 • VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 4 4 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: 014 59108 Date: Z/ Applicant: I Architect or Engineer: Applicant's Mailing Address: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Ce, and my License is in full force and effect. //License Class_ License No.y �/ Date T d ontractor /-17-0 _Z_AA�_ - OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that 1 am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively cpntracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a-contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is / s,` Md. lrbly 5mpensatio urance carrier and policy number are: Carrier /1` f Policy Number 1 101 5) f S _!2S1y _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to he workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. ate Applicant WARNING: FAILURE TO SECURE W RKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lenders Name Lender's Address 0/4 APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is rade, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application beccmes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply wiall city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter u n the above-mentioned prop i pection purposes. to f D ` !D ` —D� Signature (Applicant or Agent): TMs, ,,.� k�nT d¢'ec.:•ht ,, .kjf.j,a r. z Page 2 Application Number . . . . . 04-00005968 Date 8/30/04 Qty - Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 3.00 6.5000 EA` MECH VENT FAN 19.50- 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 --------------- 'Permit . ------------------------------------------------------------ . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee 107.04 Plan Check'Fee 26.7_,6 Issue Date Valuation 0 . -_.Qty Unit Charge Per Extension } BASE FEE 15.00 .1820.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 63._.70 667.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 13.34 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . . . . PLUMBING Additional desc Permit -Fee 129.00 Plan Check.Fee 32.25 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15..00 10.00 6.0000 EA PLB FIXTURE - 60.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7,.5000 EA PLB WATER HEATER/VENT 7:,50 _. 1.00 . 3 . 0000 EA- PLB WATER INST/ALT/REP 3; 0,0„ , ' 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM i. 9.00 6.00 .7500 EA PLB GAS PIPE >=5 4.50 1.00 15.0000 EA PLB GAS METER' 15.00 Permit. . . . . . . GRADING PERMIT Additional desc Permit Fee . . 15.00 Plan Check Fee .00 Issue Date Valuation . . 0 Qty Unit Charge Per Extension 3 BASE FEE 15.00, Special Notes and Comments 1820 S.F. SFD PERMIT DOES NOT INCLUDE Page 3 Application,Number . . . . . 04-00005968 Date 8/30/04 ------------------------------------------------------- Special Notes and Comments ---------- ----------- BLOCK WALL, POOL/SPA OR DRIVEWAY APPROACH Other Fees ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00' DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 45.66 DIF FIRE PROTECTION -RES 97.00 'GRADING PLAN CHECK FEE .00 ' DIF LIBRARIES -.RES 225.00 ' DIF PARK MAINT FAC - RES 5.'00 ' • DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 11.73 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------------- Charged Paid Credited Due .Permit Fee Total ---------- 1012.54 ---------- --- - ------ ---------- .00 .00 1012.54 Plan Check Total 530.39• 250.00 .00 280.39 Other Fee.Total 2462.39 .00 .00 2462.39 Grand Total 4005.32 250.00 .00 3755.32 CERTIFICATE OF COMPLIANCE Desert Sands Unified School District Z46ERMU s O 47960 Dune � Palms Road Date 9/28/04 La Quinta CA 92253 00 RANCHO MIRAGE d �. INDIAN WELLS No. 26469 (760) 771-8515 °,A QUIN r:V .QINDIO � Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes, It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason; n EXEMPTION NOT APPLICABLE This certifies that school facility fees. imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.24 X 1,820 S.F. or $4,076.80 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Valley Independent Bank - Mark Tuvell Check No. 319666 Name on the check Telephone 272-6044 Funding Residential By Dr: Doris Wilson Superintendent Fee collected / xempted Shar GII r y Payment Recd $0.00 �-�,�/f $4,076.80 Over/Under NOTICE; Pursuant to GovemiheaLCode S # n 30(01), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run fronilibastate on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting Owner Mark Tuvell APN # 773-065-010 Address Jurisdiction La Quinta City Zip Permit # Tract # Study Area Type Single Family Residence No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 51220 Avenida Velasco 1820 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes, It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason; n EXEMPTION NOT APPLICABLE This certifies that school facility fees. imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.24 X 1,820 S.F. or $4,076.80 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Valley Independent Bank - Mark Tuvell Check No. 319666 Name on the check Telephone 272-6044 Funding Residential By Dr: Doris Wilson Superintendent Fee collected / xempted Shar GII r y Payment Recd $0.00 �-�,�/f $4,076.80 Over/Under NOTICE; Pursuant to GovemiheaLCode S # n 30(01), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run fronilibastate on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting 0 Fidelity National Title Company 72171 Highway 111 Suite 201 • Palm Desert, CA 92260 (760) 776-5770 • FAX (760) 779-0394 YOUR PURCHASE AGREEMENT AND JOINT ESCROW INSTR CTIONS ARE HEREBY AMENDED AND/OR SUPPLEMENTED IN THE FOLLOWING PARTICULARS ONLY: To: Fidelity National Title Company Date: July 6, 2004 Escrow No: 411.914 -CB Property Address: APN #773-065-010-9, La Quinta, CA 92253 The instructions in this escrow are hereby modified, amended and/or supplemented in the following particulars only: 1. All parties (Sellers and Buyers) have acknowledged receipt of Escrow Holder's executed Acceptance and that all agreements, counter offers and any addendums have been deposited with Escrow Holder and that there are no other outstanding agreements, counter offers and/or addendums which effect the closing of this transaction. Fidelity National Title Company is relieved of any and all responsibility/liability and will be held harmless as it relates to said documents not deposited to escrow. . 2. An ALTA Homeowners Policy of Title Insurance will be issued by First American Title Company at the close of escrow. 3. SALES PRICE: All parties herein are aware that the sales price of subject property is $95,000.00.- 4. 95,000.00: 4. CLOSE OF ESCROW: Close of escrow to be on or before August 13, 2004, or thereafter, unless revoked by written demand on you by the undersigned in accordance with Paragraph 7 of General Provisions attached hereto and made a part hereof. 5. FACSIMILE SIGNATURE: Escrow Holder is hereby authorized and instructed that, in the event any party utilizes "facsimile" transmitted signed documents or instructions to Escrow Holder, you are to rely on the same for all escrow instruction purposes and the closing of escrow as if they bore original signatures. Each party shall provide to. the other party and to Escrow holder, within 72 hours after transmission, duplicate original documents or instructions bearing the original signatures. Not withstanding the foregoing, any and all escrow instructions pertaining to the release or disbursement of funds from escrow prior to close of escrow shall not be effective until Escrow Holder has received such instructions from all parties bearing original, NOTARIZED, signatures. Each party further acknowledges and agrees that documents with non -original signatures may 'not be accepted for recording by the County Recorder, therefore no closing or recording may take place without the submission of the original documents. 6. CHECKS TO BE ISSUED AT CLOSE OF ESCROW: I/We the undersigned buyer/borrower/seller hereby acknowledge that we are aware that Fidelity National Title Company will issue a check payable to the undersigned in payment of sellers proceeds/borrowers proceeds or buyer's excess deposit refund. I/We further acknowledge and agree that said check will be presented to the bank for deposit as soon as possible after receipt, and collection.. and payment of the funds will only be done through the regular banking channels. In addition, in the event there are liens to be paid on the undersigned's behalf, we hereby alcn ar.knnwlAr1nP that I/wA will not imp thA nav-by-nhnnA AlArtrnnir cvCtAm to nav/rnllPrt LEGAL DESCRIPTION Order Number: 0625-1523717 (03) Page Number: 6 Real property in the City of Riverside, County of Riverside, State of California, described as follows: LOT 10 BLOCK 69 OF UNIT 9 OF SANTA CARMELITA AT VALE LA QUINTA, AS SHOWN BY MAP RECORDED IN BOOK 18, PAGE 69 OF MAPS, RIVERSIDE COUNTY RECORDS. APN: 773-065-010-9 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING..: _ CF -4R ZJAlig Project Title ' Builder ContactpD / 1 Telephone J /Iii C4rh►Do/�l ( %&10) 21?- 5-79 3 HERS ater o N ne �/ p71 s 7 Sample House Number HERS Provider: C HEE IQ_'5- City/State/Zip: L uj�t//r7l4 F C ing Signature Date rm: 17C--A,5O/C/a��S Street Address: 79�b b �l'4��oV�/YL �>✓ Copies to: Builder, HERS Provider HERS RATER COMPLIANCE STATEMENT 4? r d Z�L Builder Name Plan Number Sample Group Number The house was: XTested; ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form com with the diagnostic tested compliance requirements as checked on.this form. Distribution system is fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu oef ducts) Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM ZQ If fan flow is calculated as 400cfm/ton x number of tons enter UU calculated value here If fan flow is measured enter measured value here Leakage Percentage Test Leakage/Fan Flow) _ (100 x Check Box for Pass or Fail (Pass=6% or less) ❑ Pass Fail THERMOSTATIC EXPANSION VALVE (TXV) or Commission approved equivalent Yes ❑ No Thermostatic Expansion Valve (or Commission approved equivalent) is installed and Access is provided for inspection ❑ Yes is a pass Pass Fail ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1. ❑ Yes ❑ No ACCA Manual D Design requirements have been met (rater has verified that actual installation matches values in CF -1 R and design on plan. 2. ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, verified fan flow matches design from CF -1 R. Measured Fan Flow = Yes for both 1 and 2 is a Pass -Pass Fail AMill ��.� �, r s.- �� Cee te of�-0ccu n c _1Y �M p j y, Q :,pa . - oti f -, v _ O `� a f' --h: yR y:{. c .f ._z :. i ..fir., _ �� .�:�•,r _ _ ti " .4.Sr': �.�ft^:� _ 4 A !.MML C I i UMMORATM 192 T. "� 4 ;�, _ � � .a, - ., ' e' �-� ` � y ~ r�. � t� -�;, _'- -'J 0 qZ Bu�ld�ng. & a et Dep M. F•ar j� � ;....'� a e . 7'� J _p --,'of "Section .109 -of "th il din g - -this, &edwcate -is issued. pursuant,, to the -requirements, 6.California '", B J. 1. tell,, �,Code- .0 '. at'the ime`.­bf_issuance, this 'structure _.wasAcompliance, ompfiance;:'with e't, (' brtifying, that, - . yA.provisions of the�Buildinis,-Co�bedihan&es.-oft4h6--City ie-guild-r-ingibuildin'a te--,'dnd"itie'-,va-rid-us, , construction - F. andlor use.,,., AMill ��.� �, r s.- �� Cee te of�-0ccu n c p j y, Q :,pa . - oti f -, v _ O `� a f' --h: yR y:{. c .f ._z :. i ..fir., _ �� .�:�•,r _ _ ti " .4.Sr': �.�ft^:� _ 4 A !.MML C I i UMMORATM 192 T. "� 4 ;�, _ � � .a, - ., ' e' �-� ` � y ~ r�. � t� -�;, _'- -'J 0 qZ Bu�ld�ng. & a et Dep M. F•ar j� � ;....'� a e . 7'� J _p --,'of "Section .109 -of "th il din g - -this, &edwcate -is issued. pursuant,, to the -requirements, 6.California '", B J. 1. tell,, �,Code- .0 '. at'the ime`.­bf_issuance, this 'structure _.wasAcompliance, ompfiance;:'with e't, (' brtifying, that, - . yA.provisions of the�Buildinis,-Co�bedihan&es.-oft4h6--City ie-guild-r-ingibuildin'a te--,'dnd"itie'-,va-rid-us, , construction - F. andlor use.,,., z- 'vBU1Lb AdADDRESS-'M--220 AVENIDA.VtLASCO 11131 Ul Us: �e I a-ssifidation:1SIFID *13 N6: 04-5968 'T�f.Cohstr6ctiqkVw tY-3 Occupancy Group: R-3 peio jl. Yv, -Z VY Owner of Building: MTB'-, Address 50855 WASHINGTON ST #149 'City,ItTi ZIP: LA QUINTXCA 92253: -By-,'KIRKKIRKI3X AF ND Date: 4-ij,2005 I _q Official r Bui difi' 7� POST IWA CONSPICUOUS PLACE: AMill �, { • � "� 4 ;�, _ � � .a, - ., ' e' �-� ` � y ~ r�. � t� � } v - .ter ? F kj- � ;....'� a e . 7'� _p TITLE 24 REPORT Title 24 Report for: La Quinta, CA 92253 Project Designer:. Mark Tuvell Report Prepared By: _ Jason Campanella 50-855 Washington St. #149 La Quinta, CA 92253 (760) 590-9501 CITY OF LA°QUINTA Job Number: 'BUILDING & SAFETY DEPT, APPROVED 0005 FOR CONSTRUCTION. DATE3�I_&V_ BY ,5T Date: oFF,c� 8/18/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. 0005 User Number. 5961 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary' 1 2 3 6 8 12 13 EnergyPro 3.1 By EnergySoft Job Number. 0005 User Number. 5961 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Project Title Date 8/18/2004 La Quinta Project Address Building Permit # Jason Campanella (760) 590-9501 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,821 ft2 Total Conditioned Slab Area: 1,821f? Average Ceiling Height: 9.0 ft Building Type: Area (check one or more) Fenestration Exterior © Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing. Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Const. Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc. Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation R-15 Wall (W.15.2x4.16) Wood 0.081 Exterior Wall R-38 Roof (R.38.2x4.24) Wood 0.024 Exterior Roof FENESTRATION Shadinn Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U - Factor Shading Yes / No Yes / No Left 33.4 0.74 0.66 Bug Screen ❑ Q ❑ Q Left 4.5 0.46 0.37 Bug Screen ❑ x❑ ❑ X❑ Rear 32.0 0.61 0.39 Bug Screen ❑ X❑ ❑ Q Rear 12.6 0.46 0.37 Bug Screen ❑ 0 ❑ Q Right 6.0 0.61 0.39 Bun Screen ❑ x❑ ❑ Q Right 12.0 0.46 0.37 Bug Screen ❑ X❑ ❑ 0 Right 33.4 0.74 0.66 Buq Screen ❑ X❑ ❑ Q Front 33.4 0.74 _ 0.66 Bun Screen ❑ 0 ❑ X❑ Front 26.7 0.46 0.37 Bug Screen ❑ 0 ❑ a Front 72.0 0.61 0.39 Bug Screen ❑ Q ❑ 0 ❑ ❑ ❑ ❑ ❑❑ 1:1 El Run Initiation Time: 00/18104 06:36:56 Run Code,• 1092836216 Ener Pro 3.1 By Ener Soft User Number: 5961 Job Number: 0005 Page: 3 of 13 Certificate of Compliance: Residential (Part 2 of 2) CF R Tank Energy Fact! 1 -1 Water Heater Water Heater Distribution # in Input 8/18/2004 Project Title Tank Insul. Date HVAC SYSTEMS Note: Input Hydronlc or Combined Hydronic data under Water Heating Systems, except Design Heating Load. (gal) Distribution R -Value Heating Equipment Minimum Type and Duct or 47 Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Fumace 92% AFUE Ducts in Attic 42 Setback HVAC System Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0' SEER Ducts in Attic 42 Setback HVAC System WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value STATE S** -52-1 HE Heat Pump_ Standard 1 15,359 47 1.90 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS GUMPLIANGE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Mark Tuvell Address: Telephone: Lic. #: (signature) Enforcement Agency Name: Title/Firm: _ Address: Telephone, (date) Name: Title/Firm: Jason Campanella Address: 50-855 Washington St. #149 T (signature/stamp) (date) Run Initiation Time: 08/18/04 06.36.56 Run Codes 1092836216 EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number. 0005 Page:4 of 13 ..Certificate of Compliance: Residential (Addendum) CF -IR 8/18/2004 Project Title Date Special Features and Modeling Assumptions. The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies Msee on me auequacy of me speciar JusuncaZwn ana uocumenwoon suDmmeo. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS Plan I Field Provruer. lilt: nr-no rarer must uocumeni me new vermcaiwn ana magnostic iesung oT mese measures on a Torm GF-bR. —Ofin7 Field The HVAC System "HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 08/18104 06:36:56 Run Code: 1092836216 EnergyPro 3.1 By EnergySoR User Number: 5961 Job Number. 0005 Page:5 of 13 Mandatory Measures Checklist: Residential (Page 1..of 2) MF -1 R NOTE: Lowdse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures '§150(.): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. ❑X '§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). 04150(d): Minimum R-13 raised floor insulation in framed floors or equivalent ❑§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 permfinch. a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ®116-17: Fenestration Products, Exterior Doors and Infiftration/Exfiltrabon Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. El§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures a§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. © §150(h): Heating and/or cooling loads calculated in accofdance with ASH RAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number: 0005 Page:6 of 13 Mandatory Measures Checklist: Residential '(Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) FX 1150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible dud shall not be used for conveying conditioned air. Building cavities and support platforms may contain duds. Duds installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the duds. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive dud tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36' of pipe between fitter and heater for future solar, cover for outdoor pools or spas. a. At least 35' of pipe between finer and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 Iumenstwatt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. RX §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling factures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5861 Job Number: 0005 • Page:7 of 13 \ II ,computer Method Summa Part 1 of -3C-2R +� 18/18/2004 Project Title f Date 11 La .Quinta Project Address Building Permit # Jason Campanella (760) 590-9501 Documentation Author} Telephone Plan Check/Date Computer Performance I 15 + Field Check/Date 1f Compliance Method (Package or Computer). Cimate Zone ,l Source Energy Standard Use (kBtu/sf-yr) Design Space Heating 0.83 Facing North Margin Total Conditioned Floor Area: Facing . East Margin - Facing South Margin ❑ Facing II West Margin 0.28 0.55 0.11 0.72 0.05 0.78 0.16 0.67 Space Cooling 31.60 26.37 5.24 14.6% 1 29.80 1.81 Number of Dwelling Units: 30.19 1.41 Total Conditioned Volume: 28.67 2.94 Domestic Hot Water 13.8411.14 - 2.70 1 111 Total Conditioned Slab Area: 11.14 .2.70 BUILDING ZONE INFORMATION 11.14 2.70 # of 11.14 2.70 37.79 8.491 1 41.04- 5.23 41.38 4.89 39.97 6.30 .Totals 46.27 , IR21 X6,3.89 1 00 -co wetback- -n/ 1.3 This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations. ]� ® Total Conditioned Floor Area: 1,821 ft 2 Wall 387 0-081 180 9.0_ [X ❑ Building Type: Single Fam Detached Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Front Orientation: All Four Orientations Total Fenestration Area: 14.6% 1 R-15 Wall (1N 15 2x4 16) 1st Floor 1t Number of Dwelling Units: 1.00 Total Conditioned Volume: 16,389 ft741 2 s Number of Stories: 1 111 Total Conditioned Slab Area: a 1,821 ft j BUILDING ZONE INFORMATION ❑ # of Thermostat Vent Zone Name I1 Floor Area Volume Units Zone Type Type Hgt. Area HVAC System IR21 X6,3.89 1 00 -co wetback- -n/ ❑❑ ❑ OPAQUE SURFACES Act. I ` Solar k Gains Type Area U -Val. Azm. Tilt Y / N Form 3 Reference Location/ Comments Wall 124 0.081 9D g0 ® R_15 Wall (W 15 2x4 16) 1st. Floor l Wall 387 0-081 180 9.0_ [X ❑ R-1 15 ON If Ii 2Y4 16) 1st Floor If Wall _318_ 0-081 270_ ---90-15rN� ❑ R-15 Wall (IN7Y4 16) 1SLF1o.or* lE Wall _39.9 0 .081 0 90 L ❑ R-15 Wall (1N 15 2x4 16) 1st Floor 1t Roof ---J-,821 -0_02 0 n 0 ®❑ R-38Roof (R 38 2x4 24) 1st Floor 1[ s ❑ ❑ *, ❑ ❑ , r F ❑ t ❑ ❑ r ❑❑ ❑ ❑ f ❑ ❑ 11 F-1 F-1 i F-1 1-1 ,i ❑ ❑ i f i ❑ ❑ i I ❑ ❑ ; ❑❑ ❑ ❑ it F-1 F-1 ❑ ❑ l ❑ ❑ 11 r F-1 1-1 i s l ❑ ❑ li d ❑ ❑ if ❑ ❑F-1 li r F1 11 [ ❑ ❑ Run Initiation Time: 08/18/04 06:36:56 Run Code: 1092836216 !I 3.1 By EnergySoft User Number: 5961 0005 Page4of 13 Run Initiation Time: 08, M 04 06:36:56 Run Code: 1092836216 1 EnergyPro 3.1 By EnergySoft !User Number: 5961 Job Number: 0005 Page:9 of 13 `F f _Computer Method Summary (Part 2 of 3) C -2R 8/18/2004 Project Title Date lE FENESTRATION SURFACES r U- Act. Glazing Type Location/1 # Type Area Factor SHGC Azm. Tilt Comments -11- Window Left (East). _331- _OZ4U -0-66 20- 9D 11dt1 Thermal Brk Clear Default 1stFloor 2 Window Left (East) 4.5 ' 0.460 0.37 90 90 Mtl Thermal Brk Clear Default 1st Floor II 3 Window Rear (South) 16.0 0.610 0.39 180 90 Mtl Thermal Brk Clear Default 1st Floor 1L 4 Window Rear (South) 16.0 0.610 0.39 180 90 Mtl Thermal Brk Clear Default 1st Floor 11 5 Window Rear (South) 12.6 0.460 0.37 180 90 MU Thermal Brk Clear Default 1st Floor it 6 Window Right (yllest) 6.0 0.610 0.39 270 90 MU Thermal Brk Clear Default 1st Floor l[ 7 Window Right (West) 12.0 0.460 0.37 270 90 Mtl Thermal Brk Clear Default 1st Floor 'r 8 Window Right (West) • 33.4 0.740 0.66 270 90 Mtl Thermal Brk Clear Default 1st Floor 9 Window Front (North) 33.4 0.740 0.66 0 90 MU Thermal Brk Clear Default 1 st Floor Jl 1Q Window • Front (North) 26,7 0.460 0.37. 0 90 Md Thermal Brk Clear Default 1 st Floor Jr 11 Window Front (North) 35.0 0.610 0.39 0 90 Mtl Thermal Brk Clear Default 1st Floor ii 12 Window Front (North) 12.0 0.610 '0.39 0 90 Mtl Thermal Brk Clear Default 1st Floor Ii -U Window Front (North) 25.0 0.610 0.39 0 90 Mtl Thermal Brk Clear Default 1st Floor A - 1f If - f f INTERIOR AND EXTERIOR SHADING c Window Overhang + Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt Dist. Len Hgt Dist' Len Hgt 1 Bug Screen 0.76 11 2 Bug Screen 0.76 l 3 Bug Screen 0.76 ll 4 Bug Screen 0.76 11 5 Bug Screen 0.76 E 6 Bug Screen. 0.76 l 7 Bug Screen i 0.76 8 Bug Screen 0.76 9 ug Screen ., 0.76 10 . Bug Screen0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 11 13 - Bug Screen 0.76 j 11 p - - - 'f i 1 I + i i 11 i li ii JI 11 Run Initiation Time: 08, M 04 06:36:56 Run Code: 1092836216 1 EnergyPro 3.1 By EnergySoft !User Number: 5961 Job Number: 0005 Page:9 of 13 `F f ^Gomputer Method Summary Rated/ (Part 3 of 3) C -2R 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency 8/18/2004 Project Title 1 15,359 47 1.90 n/a i n/a Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Frame Wall Stucco 124 0.88 91 047 R15AAtalL_(7QL15.2 _2 1s Floor / Exterior Mass Frame Wall, Stucco 387 0_88 21 0_47 R-15 Wall (W.15.2x4.16) 2 1 st Floor / Exterior Mass Frame all, Stucco 318 0_88 21 0.47 R-15 Wall (W.15.2x4 16) 2 1st Floor / Exterior Mass Frame Wall, Stucco 309 0.88 21 0.47 R-15 Wall (W.15.2x4.16) 2 1 st Floor / Exterior Mass PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 92%AFUE Ducts in Attic 4.2 Setback HVAC System Hydronic Piping Pipe Pipe Insul. System Name Length -Diameter Thick. Cooling Equipment. Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System r WATER HEATING SYSTEMS Rated/ Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. STATE S"-52-1 HP Heat Pump Standard 1 15,359 47 1.90 n/a i n/a 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 08/18/04 06:36:56 Run Code: 1092836216 EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number 0005 Page: 10 of 13 ,;,Computer Method Summary (Addendum) , C -2R 8/18/2004 Project Title Date Special Features and Modeling As The local enforcement agency should pay special attention to the items specked in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aaencv determines the adenuacv of the iustifir_atinn_ and may reiert a huiidinn nr docinn that nthanuico rmmnfioc )ased on the adequacy of the special justification and documentation submitted. ' Plan I Field HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field The HVAC System "HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow.: i Run Initiation Time: 08/18/04 06:36:56 Run Code: 1092836216 EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number: 0005 ' Page: 11 of 13 ]HAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE 8/18/2004 SYSTEM NAME FLOOR AREA HVAC System 1' 821 NGINEERING'CHECKS SYSTEM LOAD EATING S 26.0 OF Outside Air 0 cfm 69.1 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM 11 Sensible 2,524 32,199 4,278 636 26,138 0 79.2/69.5°F 79.2/69.5°F 64.9/64.1°F 1,610 1,307 0 0 0 0 0 0 0 Supply Fan Cooling Coil 0 0 1,610 1,307 TOTAL SYSTEM LOAD 35,4 4 278 28 752 HVAC EQUIPMENT SELECTION BDP CO. 563AN036-A 19,801 13,846 56,000 Total Adjusted System Output 19 801 13,846 56,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm l Jan 12 am tream Temberatures at Time of Heating Peak) 69.1 OF 69.1 OF 109.5 OF Supply Fan Heating Coil 1300 cfm k Return Air Ducts � Supply Air Ducts l 108.6 OF ROOMS 70.0 OF I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6°F 79.2/69.5°F 79.2/69.5°F 64.9/64.1°F JJW Outside Air Supply Air Ducts 0 cfm' Supply Fan Cooling Coil ',66.0 / 64.5 OF 1300 cfm 64.5% ROOMS T R.H. 79.2/69.5 °F ;78.0/69.1°F Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number: 0005 Page: 12 of 13 r LK M LOAD SUMMARY PnUJECT NAME SYSTEM NAME i ' HVAC S •stem DATE 8/18/2004 FLOOR AREA . 1.821 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE 1 st Floor 1 st Floor 1 2,524 32,199 4,278 2,524 32,199 4,278 636 26,138 r PAGE TOTAL 1 2,524 32,199 4,278 TOTAL 2,524 32,199 4,278 636 26,138 636 26,138 EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number: 0005 Page: 13 of 13