Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
11-0359 (RER)
,1 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 11-00000359 ' Property Address: 51740 AVENIDA VELASCO APN: 773-134-011-11 -000000- Application description: REMODEL - RESIDENTIAL Property Zoning: COVE -RESIDENTIAL Application valuation: 50000 Applicant: nr.i Architect or Engineer: . Py P (Pe - LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under.provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. Licens ``lass: B/ License No.i - 888454 ' ate- d� 1 ontractor- OWNER-BUILDERDE - 1 hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (.. 1 I,'as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The . Contractors' State License Law doesnotapply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or herown employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within • one year of completion, the owner -builder will have the burden of proving that he or she did_ not build or improve for the purpose of sale.)- ' (_) I, as owner of the property, am exclusively contracting withlicensed-contractors to construct the project ISec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of - property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed .pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. , BAP.C. for this reason 'Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending.agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Owner: CORELLA -EDUARDO 51740 AVENIDA VELASCO LA QUINTA, CA 92253' VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/25/11 Contractor: yy YOUNGS CONSTRUCTION 1taY 2 i 41501 BROWNSTOWN DRIVE BERMUDA DUNES, CA 9220, CITy0F (760) 238-2383 �'�Ifdrlf� Lic. No.: 888454 WORKER'S COMPENSATION DECLARATION - hereby affirm under penalty of perjury one of the following declarations: _ I have and will -maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as.required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued: My workers' compensation insurance carrier and policy number are: - Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section / 37/00 of the Labor, Code, I shall forthwith coT;Ay with those provisions. licant-- /WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000)- IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions.and restrictions set forth on this application. .1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under. or pursuant to any permit issued as a result of this application, the owner, and,the applicant, each agrees to, and shall defend, indemnify -and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives offtthi/s S_oulnty to enter upon the above-mentioned property for inspect!igp purposes. a/D le: ' -d • IA - ature (Applicant or Agent): Application Number 11-00000359 Structure Information FIRE DAMAGE REPAIR AT GARAGE [ENG] Other struct info CODE EDITION 2010 Permit BUILDING PERMIT Additional desc'. Permit Fee . . . 414.50 Plan Check Fee 269.43 Issue Date . . . . Valuation 50000 Expiration Date .11/21/11 Qty Unit Charge Per Extension . BASE FEE 252.00 25.00 6.5000 THOU, BLDG 25,001-50,000 162.50 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . 30.90 Plan Check Fee 7.73 Issue Date Valuation 0 Expiration Date 11/21/11 Qty Unit Charge Per Extension BASE FEE 15.00 20.00 ..7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 2.00 .4500 EA ELEC DEVICE/FIXTURE->20 .90 Permit MECHANICAL. Additional-desc . Permit Fee . . . 48.00 Plan Check Fee 12.00 Issue Date . . . . Valuation . . . . 0 ' Expiration Date 11/21/11 Qty Unit Charge Per Extension BASE 'FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 .1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 EA MECH AH <=10K CFM 6.50 2.00 6.5000 EA MECH VENT FAN 13.00 Permit . . PLUMBING Additional desc . Permit Fee 24.00 Plan Check Fee 6.00 . Issue Date . . . . Valuation . . . . 0 Expiration Date 11/21/11 Qty Unit Charge Per Extension LQPERMIT t Application Number. . . . . . i1-00000359 Permit . . ... . . PLUMBING Qty Unit Charge Per Extension BASE" FEE 15.00 1.00 6.0000 EA PLB FIXTURE 6.00 1.00 3.0000 EA PLB WATER.INST/ALT/REP 3.00 -------------------------------=-------------------------------------------- Special Notes and Comments FIRE'DAMAGE REPAIR AT ATTACHED GARAGE [ENGINEERED] THIS PERMIT INCLUDES MINOR REPAIRS TO DWELLING INTERIOR, WINDOW CHANGE OUTAAND REPLACEMENT OF HVAC SYSTEM. 2010 CALIFORNIA BUILDING CODES. May 24, 2011 4:54:34 PM AORTEGA --------.---------------------------------------------------- Other Fees . . . . BLDG STDS ADMIN (SB1473) 2.00' ENERGY REVIEW FEE •26.94 • STRONG MOTION (SMI) - RES 5.00 Fee summary Charged Paid Credited -- ---------- ---------- --------=- Due ----------------- -------- Permit Fee Total 517.40 00 .00 517.40 Plan Check Total 295.16 .00 .00 295.16 Other Fee Total 33.94 .00 .00 33.94 Grand Total 846.50" .00 .00 .846..50 LQPERMIT Bin # ac� : Qty ofLa:Q•unta Building 8t' Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 ' Building Permit Application and Tracking pp c Ing Sheet Permit # Project Address:%Q- `�' Q% 4 ' d sip Owner's Name: D-+ A. P. Number: Cpce, • (' Address: 5�4sy$- Legal Descri' Cactor: City, ST, Zip: L—Q Telephone: X719 S78• %r ;::>:<•:3' ";Y;::;: ;l:»:::r,.: oq'��iv:'f..:ii:•.. vh Y.'rvi:•:{f•:V rJr:i{•}� Address: Project Description: ((- 2OST 0V2 O F C ity, il Zip: �/ . " S)2ce�► CZ�P o� .� Telep one: ::z>••: •:..::.:.;;;•:<;::; State kc. # Designer: Address: City, ST, Zip: Telephone: 760'(0/ 5 a ,.,�. State Lic. #: # . •'•> : l :.z::: >:::x.. :.;z�::::>::: , nstructionType: Occupancy: Project type (circle one):. New Add'n Alter epai Name of Contact Person: ,_ Ptar2La Z Sq. Ft.:Cf- O C(. #Stories: #Units: Telephone # of Contact Person: �7(7O 1 q • Z757 Estimated Value of Projec t�1 080 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Plan Sets Req'd Rec'd 0�_ TRACMG c� Plan Check submitted T PERMIT FEES It,, A ount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cates. Called Contact Person s Plan Check Balance. Title 24 Calcs. _Plans picked up ��' ConstructionFlood plain plan Plans resubmitted Mechanical Grading plan 2°' Review, ready for correctio �l Electrical ' Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 3" Review, ready for correctionVissue . Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees n_�63��)� 5107 is st ?V, - Iia I2 J4f �' - ;r►�' -a � flr BUILDING ENERGY.ANALYSIS REPORT PROJECT: r Corella Residence 51-740 Avenida'Velasco La Quinta,,CA 92253 Project Designer: Perez Collaborative Drafting & Consulting 82-204 Hwy 111, Suite C Indio, CA 92201 (760) 619-8752 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 Met 11.00 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Job Number: f DATEBY Date: "mor 4/29/2011' The EnergyPro computer program has been.used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number. 6712 RunCode: 2011-0429710:19:27 /D: • • 0 • 1] 1� PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Corella Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 4/29/2011 Project Address 51-740 Avenida Velasco La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 1,040 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity ftz) Features see Part 2 of 5 Status Roof Wood Framed Attic R-19 920 Existing Roof Wood Framed Attic R-30 120 Altered Wall Wood Framed R-11 722 Existing Door Opaque Door None 20 Existing Wall Wood Framed R-13 320 Altered Slab Unheated Slab -on -Grade None 1,040 Perim = 132' Existing FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Left (N) 16.0 0.400 0.35 none none Bug Screen Altered Rear (E) 48.0 1.190 0.83 none none Bug Screen Existing Rear (E) 10.5 0.400 0.35 none none Bug Screen Altered Rear (E) 39.0 0.400 0.35 10.0 none Bug Screen Altered Front (tM 40.0 0.400 0.35 6.0 none Bug Screen Altered HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback Altered HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Altered HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2011-04-29T10:19:27 ID: Page 3 of 14 • r� 1� PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Corella Residence Building Type m Single Family 11 Addition Alone ❑Multi Family m Existing+ Addition/Alteration Date 4/29/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The, HVAC System Altered.HVAC incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by Energ ySoft User Number: 6712 RunCode: 2011-04-29T10:19:27 /D: Page 4 of 14 U • PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Corel/a Residence 1 ❑ Multi Family m Existing+ Addition/Alteration, 1412912011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.61 5.99 -0.39 Space Cooling 119.78 108.86 10.92 Fans 23.74 24.86 -1.12 Domestic Hot Water 24.12 24.12 0.00 Pumps 0.00 0.00 0.00 Totals 173.25 163.84 9.41 Percent Better Than Standard: 5.4% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (tnq 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (M 480 40 Fuel Available at Site: Natural Gas (N) 208 16 Raised Floor Area: 0 (E) 320 98 Slab on Grade Area: 1,040 (S) 208 0 Average Ceiling Height: 8.0 Roof 1,040 0 Fenestration Average U -Factor: 0.65 TOTAL: 154 Average SHGC: 0.50 Fenestration/CFA Ratio: 14.8% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 4 9/2011 Address 77-085 Michigan Drive Name Jon Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Perez Collaborative Drafting & Consulting Address 82-204 Hwy 111, Suite C Name Juan Perez City/State/Zip Indio, CA 92201 Phone (760) 619-8752 Signed License # Date EnerqvPro 5.1 by Ener Soft User Number: 6712 RunCode: 2011-04-29710:19:27 /D: Page 5 of 14 I 01. 4 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of -5) ;CF -1 R Project Name Corella Residence Building Type m Single Family ❑ Addition Alone ^• . ❑ Multi Family ' m Existing+ Addition/Alteration Date 1412912011 OPAQUE SURFACE DETAILS . Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 920 0.049 R-19 0 22 Existing 4.2.1-A4 Altered Residence Roof 120 0.032 R-30 0 22 Altered 4.2.1-A8 E=4.2.1 -A4 Altered Residence Wall 192 0.110 R-11 0 90 Existing 4.3.1-A2 Altered Residence Wall 223 0.110 R-11 90 90 Existing 4.3.1-A2 Altered Residence Wall 208 0.110 R-11 180 90 Existing 4.3.1-A2 Altered Residence Wall 100 0.110 R-11 270 90 Existing 4.3.1-A2 Altered Residence Door 20 1.450 None 270 90 Existing 4.5.1-A1 Altered Residence Wall 320 0.102 R-13 270 90 Altered 4.3.1-A3 E=4.3.1 -A2 Altered Residence Slab 1,040 0.730 None 0 180 Existing 4.4.7-A1 Altered Residence FENESTRATION SURFACE DETAILS ID Type Area 1.1 -Factor' SHGC2 Azm Status Glazing Type Location/Comments 1 Window 16.0 .0.400 NFRC 0.35 NFRC 0 Altered Dual Non -Metal Tint Altered Residence 2 Existing - 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 3 Window 48.0 1.190 Default 0.83 Default 90 Existing Single Metal Clear , Altered Residence 4 Window 4.5 0.400 NFRC 0.35 NFRC 90 Altered Dual Non -Metal Tint Altered Residence 5 Existing 1.190 Default 0.83 Default Single Metal Clear _ pre -altered for above 6 Window 6.0 0.400 NFRC 0.35 NFRC 90 Altered Dual Non -Metal Tint Altered Residence 7 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 8 . Window 14.0 0.400 NFRC 0.35 NFRC 90 Altered Dual Non -Metal Tint Altered Residence 9 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 10 Window 25.0 0.400 NFRC 0.35 NFRC 90 Altered Dual Non -Metal Tint Altered Residence 11 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 12 Window 24.0 0.400 NFRC 0.35 NFRC 270 Altered Dual Non -Metal Tint Altered Residence 13 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 14 Window 16.0 0.400 NFRC 0.35 NFRC 270 Altered Dual Non -Metal Tint Altered Residence 15 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-6 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS' ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht Fin Len. H t LExt RExt Dist Len Hot Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 3.5 4.0 '10.0 0.1 10.0 _ 10.0 9 Bug Screen 0.76 3.5 4.0 10.0 0.1 10.0 10.0 10 Bug Screen 0.76 5.0 5.0 10.0 0.1 10.0 10.0 11 Bug Screen 0.76 5.0 5.0 10.0 0.1 10.0 10.0 12 Bug Screen 0.76 4.0 .6.0 6.0 0.1 6.0 6.0 13 Bug Screen 0.76 - 4.0 6.0 6.0 0.1 6.0 6.0 14 Bug Screen 0.76 4.0 4.0 6.0 0.1 6.0 6.0 15 JBug Screen 0.76 4.0 4.0 6.0 0.1 6.0 6.0 EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2011-04-2 9 710:19:27 ID: Pae 6 of 14 • C CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Corella Residence Building Type © Single Family ❑ Addition Alone ❑ Multi Family © Existing+ Addition/Alteration Date 1412912011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built Altered HVAC Altered Residence 1,040 8,320 1985 Totals 01 01 1,0401 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Altered HVAC 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback Altered pre -altered for above Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Setback HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Altered HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New pre -altered for above Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas All Pipes Ins 34,000 40 0.58 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 _ o ro a U) — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number.' 6712 Runcode: 2011-0429710:19:27 ID: Page 7 of 14 Y t ' MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 „MF -1 R Project Name orella Residence Date 1 4/29/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. -' 4150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor ore uivalent U -factor. 150(f): Air retar ding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fire laces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is e ui ped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment rwater heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention,'pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinci sections of hot water pipes are insulatedper Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight,- moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number- 6712 •• RunCode: 2011-0429710:19:27 ID: Page 8 of14 r r 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date orella Residence 4/29/2011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d . §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2011-0429710:19:27 ID: Page 9 of 14 fry 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date orella Residence 4/29/2011 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch. that disables the astronomical time clock; OR an energy, management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-04-29T10:19:27 /D: Page 10 of 14 r 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Corella Residence Date 4/29/2011 System Name Altered HVAC Floor Area 1,040 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 900 18,500 Return Vented Lighting 0 Return Air Ducts 1,068 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 1,068 TOTAL SYSTEM LOAD 1 20,636 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 89,000 1,449 359 19,514 Total Output Btuh 89,000 Output Btuh/s ft 85.6 959 Cooling System 0 - Out utper System Output 46,0001 0 0 0 Total Output (Btuh) 46,000 1,449 0 Total Output Tons 3.8 959 Total Output (Btuh/s ft) 44.2 Total Output s ft/Ton 271.3 1 21,432 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 24HHB448/58CVX090 35,011 5,505 89,000 Airflow cfm/s ft 1.54 89,000 Jan 1 AM Airflow cfm/Ton 417.4 Outside Air % 0.0% Total Adjusted System Output 35,011 5,505 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 69 of 69 OF 122 OF 122 OF Heating Coil Supply Fan o 121 F 1,600 cfm J.R0 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air 0 cfm 79/64°F 4 79 / 64 OF 58157 OF 58 ! 57 OF Cooling Coil Supply Fan 59157 OF 1,600 cfm — - -- 47.5 % RDOM 78/64°F . .. .. ;� _U EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011=0429710:19:27 /D: Page 11 of 14 • • • ROOM LOAD SUMMARY Project Name Date Corella Residence 4/29/2011 System Name Floor Area Altered HVAC 1,040 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Altered Residence Altered Residence 1 1 900 18,500 1,449 900 18,500 1,449 359 19,514 PAGE TOTAL TOTAL* 900 18,5001- 1,449 359 19,514 900 18,500 1,449 359 19,514 * Total includes ventilation load for zonal systems. EnergyPro 5.1 by EnemySoft User Number.- 6712 RunCode: 2011-04 29 710:19:27 /D: Pae 12 of 14 • C ROOM HEATING PEAK LOADS Project Name Corella Residence Date 4/29/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Altered Residence Floor Area 1,040.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area Default Roof Prior 1978 to Present 920.0 R-30 Roof Cathedral 120.0 Default Wall 1978 to 1991 722.4 Dual Non -Metal Tint 105.5 Single Metal Clear 48.0 Wood Door 20.1 R-13 Wall 320.0 Slab -On -Grade perm = 132.0 ' Items shown with an asterisk (') denote conduction through an interior surface Infiltration:[ 1.00 X 1.064 X 1,040 X Schedule Air Sensible Area Fraction X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr 0.0490 44 1,984 0.0320 44 169 0.1100 44 3,496 0.4000 44 1,857 1.1900 44 2,513 1.4500 44 1,282 0.1020 44 1,436 0.7300 44 4,240 another room 8.00 X 0.391 Height ACH Page Total /60] X AT 16.977 = 2,536 TOTAL HOURLY HEAT LOSS FOR ROOM 19,514 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-04-29T10:19:27 /D: Page 13 of 14 • w RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Corella Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Altered Residence Outdoor Dry Bulb Temperature Floor Area 1, 040.0 ft' Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Range: ODaaue Surfaces Default Roof Prior 1978 to Present R-30 Roof Cathedral Default Wall 1978 to 1991 Default Wall 1978 to 1991 Default Wall 1978 to 1991 Default Wall 1978 to 1991 Wood Door R-13 Wall Orientation (N) (E) WN 4/29/2011 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 920.0 0.0490 56.0 120.0 0.0320 56.0 192.0 0.1100 23.0 222.5 0.1100 33.0 208.0 0.1100 26.0 99.9 0.1100 33.0 20.1 1.4500 33.0 320.0 0.1020 33.0 41.8 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestration Window Altered 7 Window Existing H Window Altered 6 Window Altered 5 Window Altered 4 Window Altered 3 Window Altered 2 Window Altered 1 Orientation (N) (E) (E) 112 OF 78 OF 34 OF Btu/hr 2,524 215 486 808 595 363 962 1,077 1 7,0291 Shaded Area X X X X X X X X X GLF 21.0 + 52.6 + 21.0 + 21.0 + 21.0 + 21.0 + 21.0 + 21.0 + +1 Unshaded Area X X X X X X X X X GLF = = = = = = = = - 0.0 16.0 21.0 0.0 48.0 98.6 0.0 4.5 41.8 0.0 6.0 41.8 14.0 "0.0 41.8 25.0 0.0 41.8 24.0 0.0 41.8 16.0 0.0 41.8 Page Total Internal Gain Occupants 4.0 Occupants X 2301 Btuh/occ. Equipment 1.0 Dwelling Unit X 1,6001 Btu Infiltration: 1.064 X 0.87 X 56.91 X 34 = Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM I Latent Gain 4.0 Occupants X 200 Btuh/occ. I Infiltration: 4,771 X 0.87 X 56.91 X 0.00276 = Air Sensible CFM ELA AW Btu/hr 336 4,735 188 251 294 525 504 336 7,167 Btu/hr 920 1,600 1,783 18,500 Btu/hr 800 649 • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,4491