13-0543 (SFD)4 P.O. BOX 1504 VOICE (760) 777-7012
78-495 ALLE TAMPI -
8 95 C CO �/ � � r FAX (760) 777 7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT ` INSPECTIONS (760) 77777153
BUILDING PERMIT
Date: 7/10/13
Application Number: 13-00000543 Owner:
Property Address: 52390 AVENIDA VELASCO FOREMOST I,
APN: 773-265-007-7 -000000- 70600 COU CLU
Application description: DWELLING - SINGLE FAMILY DETACHED RANCHO MI ,
Property Zoning: COVE RESIDENTIAL j JUL 2013
Application valuation: 83366
Contractor: C�!) I
Applicant: Architect or Engineer: DANT(R MA TINEZ'
81057 AVENTD —ROM
INDIO, CA 92201
(760)702-6209
Lic. No.: 926128
c
V � ,
----7--------------------------------------------------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations:
Section -7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
License Class: B License No.: 926128 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
` _ ` issued.
% Date: � 11 '1311100Contractor: �o� l y,�Q CP f V� VN.& C�"G `� —1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
• Code, for the performance of the work for which this permit is issued. My workers' compensation
OWNER -BUILDER DECLARATION insurance carrier and policy number are:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the - Carrier STATE FUND INS Policy Number 1960997
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to I certify that, in the performance of'the work for which this permit is issued, I shall, not employ any
construct, 'alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California,
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of Section
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or - 3700 of the Labor Code, I shall forthwith comply with those provisions.
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by 01 1
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: Date: 9�1 %-1 Applicant: Q� e , ai � C
(_ ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one'year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ ) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under.penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: —
Lender's Address:
LQPERMIT
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
,the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Qui nta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned prope for inspection pu oses.
Date: 1�1 i Signature (Applicant or Agent):
Application Number . . . . . 13-00000543
LQPERMIT
Structure Information
Construction Type . ...
. . TYPE V, UNPROTECTED
Occupancy Type . .
. . . DWELLG/L•-ODGING/LONG <=10
Other struct info . .
. . . CODE EDITION 2010
# BEDROOMS
3.00
FIRE SPRINKLERS yes
GARAGE SQ FTG
474.00
PATIO SQ FTG
53.00
NUMBER OF UNITS
1.00
----------------------------------------------------------------------------.
1ST FLOOR SQUARE FOOTAGE 1232.00
Permit
BUILDING PERMIT
Additional desc .
Permit Fee . . . .
567.50 Plan Check Fee
368.88
Issue Date . . . .
Valuation . . . .
83366
Expiration Date
1/06/14
Qty Unit Charge
Per
Extension
BASE FEE
414.50
34.00 4.5000
-----------------------------------------------
THOU BLDG 50,001-100,000
-----------------------------
153.00
Permit . . .
ELEC-NEW RESIDENTIAL
Additional desc .
Permit Fee . . . .
82.60 Plan Check Fee
20.39
Issue Date . . . .
Valuation
0
Expiration Date
1/,06/14
Qty Unit Charge
Per
Extension
BASE _FEE
15.00
1232.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
43.12
474.00 .0200-
ELEC GARAGE OR NON-RESIDENTIAL
- 9.48
1.00 15.0000
----------------------------------------------------------------------------
EA ELEC TEMPORARY POWER POLE
15.00
Permit . . . GRADING PERMIT
Additional desc
Permit Fee . . . .
15.00 Plan Check Fee
.00
Issue Date . . . .
Valuation
0
Expiration Date
1/06/14
Qty Unit Charge
Per.,
Extension
----------------------------------------------------------------------------
BASE FEE
15.00
Permit. . . . . . . MECHANICAL
LQPERMIT
LQPEPMIT
Application Number . . . . . 13-00000543
Permit. . . . MECHANICAL
Additional desc .
Permit Fee . . . . 59.00 Plan Check Fee
13.13
Issue Date . . . . Valuation
0
Expiration Date 1/06/14
Qty Unit Charge Per
Extension
BASE FEE
15.00
1.00 9.0000 EA MECH FURNACE <=100K
9.00
1.00 9.0000 EA MECH B/C <=3HP/100K BTU
9.00
3.00 •6.5000 EA MECH VENT FAN
19.50
1.00 6.5000 EA MECH EXHAUST HOOD
6.50.
Permit PLUMBING
Additional desc .
Permit Fee . . . 109.50 Plan Check Fee
28.88
Issue Date Valuation
0
Expiration Date 1/06/14
Qty Unit Charge Per
Extension
BASE FEE
15.00 .
7.00 6.0000 EA PLB FIXTURE
42.00
1.00' 15.0000 EA PLB BUILDING SEWER
15.00
1.00 7.5000 EA PLB WATER HEATER/VENT
7.50
1.00 3.0000'EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM
9.00
1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS
3.00
1..00 15.0000 EA PLB GAS METER
15.00
-----------=----------------------------------------------------=------------
i
Special Notes and Comments
1232 SF SFD. GARAGE RT. 2010 CODES W/
FIRE SPRINKLERS. R=3 OCC. V -B CONSTR.
2013 DIF. TUMF. ARCHITECT: KEVIN L.
CROOK C15561'. **PERMIT DOES NOT INCLUDE
BLOCK WALLS, FENCES, SWIMMING POOLS,
SPA, BBQ'S and DRIVEWAY APPROACH** '
-------------------------
Other Fees . . . . . . . . BLDG STDS ADMIN (SB1473)
--------------
4.00
DIF COMMUNITY CENTERS -RES •
129.00
DIF CIVIC CENTER =- RES
942.00'
ENERGY REVIEW FEE
36.89
DIF FIRE PROTECTION -RES
433.00
DIF LIBRARIES - RES
344.00
MULTI -SPECIES (MSHCP) FEE
531.00
DIF PARK MAINT FAC - RES.
40.00
DIF PARKS/REC - RES"
2048.00
STRONG MOTION (SMI) - RES
8.34
LQPEPMIT
Application Number . . . . . 13-00000543
----------------------------------------------------------------------------
Other Fees . . . . . . . . . TUMF: RESIDENTIAL 1837.44
DIF STREET MAINT FAC -RES 116.00
DIF TRANSPORTATION - RES 2842.00
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 833.60 .00 .00 833.60
Plan Check Total 431.28 250.00 .00. 181.28
Other -Fee Total 9311.67 =.00 .00 9311.67
Grand Total 10576.55 250.00 .00 10326.55
aLW l�[CU 13.o5y3at
Veto fC0P.O. BOX 1504 APPLICATION ONLY
Building 78-495 CALLE TAMPICO
Address LA QUINTA, CALIFORNIA 92253 J
Ow /
v y 2 D r BUILDING: TYPE CONST. OCC. GRP.
Mailing s-2 y' U Py
Address A.P. Number
CityZip Tel. Legal Description
uA -t 60 3 3 - /f 6
Contractor AV ,. Project Description _4%c�t? s !�
1021N�«
10T--) 14
�119'29-6 t &v
state Lac. L.Ity
& Classif. q 2 6 / I Lic. #
Designer
•�►..� I q26 / ILic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirmtha am licensed under provisions of Chapter 9 (commencing with Section 7000)
of Division 3 of th usiness and ofessions n my license is in full force and effect.
SIGNATURE DATE
OWN R -BUILDER DE RATION
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
(Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct,
alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for
such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac-
tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any
violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of
not more than five hundred dollars ($500).
01, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not apply to an owner of property who builds or
improves thereon and who does such work himself or through his own employees, provided that
such improvements are not intended or offered for sale. If, however, the building or improvement
is sold within one year of completion, the owner -builder will have the burden of proving that he did
not build or improve for the purpose of sale).
❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the
project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply
to an owner of property who builds or improves thereon, and who contracts for such projects with
a contractor(s) licensed pursuant to the Contractor's License Law)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. O Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less).
I certify that in the performance of the work for which this permit is issued, I shall not employ
any person in any manner so as to become subject to Workers' Compensation Laws of California.
Date Owner
NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for
which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes. _
Signature of applicant Date
Mailing Address
City, State, Zip
1
WHITE = BUILDING DEPARTMENT
Sq. Ft. No.
Size Sto
New 9_ Add ❑
No. Dw.
Units
Alter❑ Repair❑ Demolition
I Estimated Valuation 9' 7 17 a G G
r
PERMIT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL
CONTACT INFORMATION
NAME:
PHONE:
AMOUNT
1
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line —
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line —
FINAL DATE INSPECTOR
Issued by: —
Validated by:
Validation:
YELLOW = APPLICANT
Date
PINK = FINANCE
Date
7/11/13
No.
31720
Owner.
Foremost Homes
Address
70600 Country Club Dr
City
Rncho Mrge Zip
Tract #
J �
Type
Single Family Residence
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8515
Lot # No. Street
Unit 1 52390 Avenida Velasco
Unit 2
Unit 3
Unit 4
Unit 5
APN #
Jurisdiction
Permit #
No. of Units
S.F. Lot # No.
1232 Unit 6
Unit 7
Unit 8
Unit 9
Unit 10
Comments Certs #31719 through #31721 used for CC#379314 totaling $11,827.20
'.o
Q BERMUDA DUNES
Cn RANCHO MIRAGE t7
INDIAN WELLS
PALM DESERT ,y
LA QUINTA �.
YPINDIO y7ti
Y
773-265-007
La Quinta
1
f�tcCF.
EPVED
JUL 1:1 2013
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.20 X 1,232 S.F. or $3,942.40 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC/California Bank & Trust - James Fortson Check No. 379314
Bank Name/Recipient of Certificate
By Dr. Gary Rutherford
Superintendent
Fee collected lexemptWy S
Signature
Telephone 760-902-1662
Funding Residential
Y
.
J �
Payment
Recd�tjy0.00 �'-
$3,942.40 `',Over/Under
NOTICE: Pursuant to Government Code Section 66020(d)(1), thio dl serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
DOC #2013-0155027.
<'
04/01/2013 04:26 PM Fees: $21.00
RECORDING REQUESTED BY: Page 1 of 3 Doc T Tax Paid
Orange Coast -Title Recorded in Official Records
County of Riverside
AND WHEN RECORDED MAIL TO: Larry W. Ward
Assessor,, County Clerk & Recorder `
Foremost Homes LLC
70600 Country Club Drive ;
Rancho Mirage, CA 92270 "This document was electronically submitted
9p to the County of Riverside for recording"
523'0 PcvPilft,\d,� VG nG� Receipted by: CTOLOSSA
jJ,Z Ql °THIS SPACE FOR RECORDER'S USE ONLY:
Title Order No.: 140-1454469-66 Escrow No.: 130047JR
7-73- ! c�22-7-73-24,4-01ZGRANT.DEED
0'73 `21OS-0/S, 17g4-dw -,Oz) 3 79hl •D5' -00 S-'
THE UNDERSIGNED GRANTOR(S) DECLARE(S). The documentary transfer tax
DOCUMENTARY TRANSFER TAX is $ . y
[X] computed on full value of property conveyed, or is being disclosed d� Ire?iontenha not
[ ] computed on full value less value of liens or encumbrances remaining at time of sale. to fie aEflown op PuRic
[ ] Unincorporated area [X] City of La Quinta AND
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged,
Charles V. Cooper and Norma Lee Cooper, Trustees of the Cooper Family Trust
hereby GRANT(s) to:
FOREMOST HOMES LLC, a California Limited. Liability Company
the real property in the City of La Quinta, County of Riverside, State of California, described as:
LEGAL DESCRIPTION ATTACHED HERETO AS EXHIBIT "A" AND MADE A PART HEREOF '
Also Known as:. 6 lots various Streets, La Quinta, CA 92253
AP#: see attached
DATED February 6, 2013
STATE OF CA IF,OR IA Charles V. Cooper and Norma Lee Cooper, Trustees of
COUNTY OF i, \% 5 I D the Cooper Family Trust .
On
before me, u It Ogeirs BY:
A Notary Public in and for said State personally appeared
Charles V. Cooper and Norma Lee Cooper Charles V. Cooper, Trustee
who proved to me on the basis of satisfactory evidence to be BY:l 9S`J
the person(s) whose name(s) is/are subscribed to the within ma Lee •Cooper, Trustee 2i .
instrument and acknowledged to me that he/she/they x
executed the same in his/her/their authorized capacity(ies),
and that by his/her/their signature(s) on .the instrument ,the,q JUDITH ROGERS
person(s), or. the entity upon behalf of which the person(s) "� Commission # 1942391
acted, executed the instrument. ' z , -m Notary Public -California z
I certify under PENALTY OF PERJURY under the laws of the State z Riverside County D
of California that the foregoing paragraph is true and correct. My Comm. Expires Jul 24; 2015
WITNESS my hand and official seal.
Signature (Seal) "
MAIL TAX SAT MENTS TO PARTY SHOW ELOW; IF NO PARTY SHOWN, MAIL AS DIRECTED ABOVE:
DOC #2013-0155027 Page.2 of 3 04/01/2013 04:26 PM
Exhibit"A"
Parcel 1:
1An 12. pluck 1211, of Santa Carmclita at Vale La Quinta t;nit No. 12. in the Cit\• OI• la Quinta. County of Riverside. State of
Calilbrnia. as shown by Map on file in book I8. pages 79 and 80 of Maps. in the office ufthc County Recorderofsaid County.
Parccl<2.
fait G. Block 84. ol•Santa Carmclitai at Vale la Quinta knit No. 10, in the City oflui Quinta. County ufRiversidc, State o 1"Ca lilbrn ia.
as shown by Map on file in book 18. page 70. of.laps. in the office ofthe County Recorder uf•said County.
Parcel 3:
Lot 7. illock 85. of Santa Carmelita auVale La Quinta Unit No. 10. in the City of La Quinta. County of Riverside: State ufCalilbrnia.
as shown. by .Map on file in book 18. page 70. of Maps. in the office ofthe County Recordet-Ol'Sald Countv.
Parcel d:
Lot d. Block 98. of Santa Carmclita at Vale la Quinta knit \o. 11, in the City o]•la Quinti. County of Riverside, State 61 Caldornia.
as shown by Vlap on file in book 18. pagc75. of Maps. in the Office Ofthc County Rccordcrofsaid County.
Parcel 5: ,
Lot 22, Block 220. Of Santa Carmclita at .Vale fat Quinta knit No. 21. in the Cit\- cif la Quinta.'CO unty of Riverside. State of
Calilbrnia. as shown by Map on file in book 20.•pagc 22.of`laps. in the 61"ticefthe County Rccordcrufsaid County.
Parcel G:
IArt 20. Block 220, of Santa Carmelita'at Vale la Quinta Unit No. 2L. in the City of la Quinta, County of Riverside. State of'
California. as shown by Map on file in -book 211, page 22. uf'.1aps. in the office o ]'the Count\- Recorder of said Count\-.
DOC #2013-0155027, Page 3 of 3 04/01/2013 04:26 PM
Exhibit «A» .
Parcel l
Lot 12, Block 120, of Santa Carmelita at Vale' La Quinta Unit No. 12, in the City of La Quinta, County of Riverside, State of
California, as shown by Map on file in book 18, pages 79 and 80 ofMaps, in the office ofthe County Recorderofsaid County.
Parcel 2:
Lot 6, Block 84, of Santa Carmclita at Vale La Quinta Unit No. 10, in the City of La Quinta, County of Riverside, State of Califomia,
as shown by Map on file in book 18, page 70, of Maps, in the office of the"County Recorder of said County.
Parcel 3:
Lot 7, Block 85, of Santa Carmelita at Vale -La Quinta Unit No. 10, in the City of La Quinta, County of Riverside; State of California,
as shown by Map on file in book 18, page 70, of Maps, in the office of the County Rccordcr of said County.
Parcel 4:.
Lot 4, Block 98, of Santa Carmelita at Vale La Quinta Unit No. 11, in the City of La Quinta; County of Riverside, State of Cal ifomia,
as shown by Map on Dile in book 18, page 75, of Maps, in the office of the County Recorder of said County.
Parcel 5:
Lot 22, Block 220, of Santa Carmelita at Vale La.Quinta Unit'No. 21, in the City of La Quinta, County of Riverside, State of
California, as shown by Map on file in book 20, page 22, of Maps, in the office o f the County Recorder of said County.
Parcel 6:
Lot 20, Block 220, of Santa Carmelita at Vale La Quinta Unit No. 21, in the City of La Quinta, County of Riverside, State of
California, as'shown by Map on file in book 20, page 22,'ofMaps, in the office of the County Recorder of said County.
CERTIFICATION
Under the provisions of Government Code 27361.7 1
Certify under the penalty of perjury that the following is a
true copy of illegible wording found in the attached
document:
Date.
Signature:
?nnt Name: jV1 02 U I i�� .
JAN -16=2014 THU 06:02 PM RIVERSIDE COUNTY FIRE `FAX N0, 17608637072 P. 01
Riverside County -Fire Department Fire Protection Planning Section
'
Riverside Once; 2300 Markel SL, Ste, 150, Riverside, CA 02501 Ph. (651) 055-4777 Fax (651) OGD -4885 -
Palm Coon Off1co: 77.933 Las Mnnranas Rd„ 0 201 F.Am Doan, CA 9121 14131 Ph. (76+0) 80.8886 Fax (760) 861,7M
Fire- Department Clearance/Release
Date: 1/16/2014
To: LA QUINTA B&S
Fax:
Tract/Parcel Map #:
FOREMOST.
Permit/Lot #:
LAQ-13-RS-035
Job Site Address:
52390 AVENIDA VELASCO
City, State, Zip
LA QUINTA
® Final For Recordation
❑ Final for Alarm System
Final for Fire Suppression System
❑ Shell Final Only (No Tenant)
❑. Release For Residential Sprinkler Installation
❑ Building Plan Check Fees Paid, Water Requirement Met- if water applicable
Building Plan Check Fees Not Paid
Residential Sprinkler Plan Check Fees Paid
❑ Residential Sprinkler Plan Check Fees Not Paid
❑ Other Fees
�j Fees Not Required
If you should have any questions, please contact the appropriate' Riverside County Fire Protection Planning office for
further assistance.
KOHL HETRICK
Print Name of Plan Reviewer/Inspector Approved Release
Sent By: Print Name
Farm C — Revised 3/01/2012
r
• RIVERSIDE COUNTY RR&PEPARTM. ENT
IN COOPERATION rH
THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION
77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 922114131 • Phone (760) 863-8886
r Fax(760)863-7072
www.rvcfire.org
PROUDLY SERVING THE
UNINCORPORATED AREAS
OF RIVERSIDE COUNTY
AND THE CITIES OF:
BANNING
BEAUMONT
CALIMESA .
CANYON LAKE
COACHELLA
DESERT HOT SPRINGS
EASTVALE ,
INDIAN WELLS
INDIO
LAKE ELSINORE
LA QUiNTA
MENIFEE
MORENO VALLEY
PALM DESERT
PERRIS
RANCHO MIRAGE
RUBIDOUX CSD
SAN JACINTO
TEMECULA
WILDOMAR
BOARD OF
SUPERVISORS:
BOB BUSTER
DISTRICT 1
JOHN TAVAGLIONE
DISTRICT 2
JEFF STONE
DISTRICT 3
.JOHN BENOIT
DISTRICT 4
MARION.ASHLEY
. DISTRICT 5
June 24, 2013
Residential Fire Systems
Re:' Residential Fire Sprinkler Plan Review
LAQ-I3-RS-035 Foremost Homes 52-390 Avenida Velasco La Quinta, CA
The sprinkler plans you submitted for the above referenced project have been reviewed by
Riverside County Fire Department Planning &Engineering personnel and are approved with
the following conditions:
A minimum of three spare fire sprinklers of each type and temperature rating along with a
sprinkler wrench should be located in a spare head cabinet at the system riser or other approved
location.
Permanently marked identification signs shall be attached to all control valves.
A warning sign, with minimum % inch letters, shall be affixed adjacent to the main shutoff
valve and shall state the following:
WARNING: The water system for this home supplies fire sprinklers that require certain flows
and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or
automatically shut off the water to the fire sprinkler system, such as water softeners, filtration
systems, and automatic shut-off valves, shall not be added to this system without a review of
the fire sprinkler system by a fire protections specialist. DO NOT remove this sign.
The following inspections/tests are required to be witnessed by the Fire Department Planning
Division staff:
(a) Overhead Rough and Hydro static test: All piping shall be visible and
pumped at normal operating pressure.
(b) Final inspection.
The Fire Department job card, approved plans and conditions letter must be at the job site or
NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire
Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection
date.
All questions regarding the meaning of these conditions should be referred to the Fire
'Department Planning & Engineering staff at (760) 863-8886.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspe ion.
• •,� I i
Sincerely,
Jas4tubble
Fire Safety Specialist
U1CV-.AAUU1fUTITLE 24 INC. -
7544 SADDLEHILL TRAIL, ORANGE, CA 92869 (714) 771-1507 • FAX (714) 771-2939 • T-24@socal.rr.com
April 18, 2013 i
Owner: Foremost Homes
70600 Country Club Drive
Rancho Mirage_, CA *92270 CITY OF.
LA Q
BUILDING & S4EE Y DEPT
APPROVED.
Designer: Kevin L. Crook Architect, Inc. FOR CONSTRUCTION
1360 Reynolds Avenue, #110.pq to t3
Irvine,,CA 92614, BY 1
Project: La Quinta Housing Projects
Plan;,1232 - Lot 7 (52390 Avenida Velasco) ,
La Quinta, California
Job No. 070.57
• VENTILATION FOR INDOOR AIR QUALITY
{ E "f e 1 • '
The following calculations are in compliance with section 150(o) of the 2008 Building Energy
Efficiency Standards, for- low-rise residential buildings. The ventilation fan selection has a.
certified airflow rating that meets or,exceeds the required minimum airflow when measured
.25" w.c. for continuous operation. The minimum duct size specified must meet the
requirements of Table 4-9 in the' Residential Energy Manual. -In addition, other-mandatory
requirements for indoor air quality are listed on the following pages.
C4
Prepared By:
-,L BE.0/(I!ck Maurer
California Association of Building Energy Consult-Rs ECEIV Energy Plans Examiner
Certificate No. R08-88-1601 and NR08-88-3583
RMaurer alifornia State License No. 502290 C20
R08-90-24343 s. NR08-90x27 APR 2 6 201
e
CTTY.OF LA QUINTA
COMMUNtTY'DEVELOPMENT ; e '
Continuous Ventilation Calculation
CFA 100 + 7.5 (# of Bedrooms -+I) = Ventilation Rate.(Min. CFM @'.25" W:C.)
Plan -1232 — Lot 7
1232-100+7.5(3+1) = 12.32+30.0=42.32 Min. CFM.
Fan Selection:
Broan #SSQTXE080 (or Equal) (One. Required)
55 CFM @.2Y W.C. ,
3
Sones'-.
Ventilation Exhaust Duct Size:
6"0 Flexible Metal Duct (or alternate per Table 4-9 CEC Residential Manual)
No Limit on Duct Length
1
Indoor Air Quality and Mechanical Ventilation
All low-rise residential buildings.are required to have a whole -building ventilation system and
satisf.,, other requirements to achieve acceptable indoor air quality (IAQ). The Energy
Commission adopted the requirements of ASHRAE Standard 62.2-2007, except that opening and
closing windows (although permitted by ASHRAE) is not an acceptable option for providing
whole -building ventilation in California.
The mechanical ventilation and indoor air quality requirements are mandatory measures. The
applicable sections are §150(o) for new construction and §152(a) for additions.
The following bullet points summarize the key requirements for most residences.
• A whole -building mechanical ventilation system shall be provided.
• Kitchens and bathrooms shall have local exhaust systems vented to the outdoors.
• Clothes dryers shall be vented to the outdoors.
• Ventilation air shall come from the outdoors and shall not be transferred from
adjacent dwelling units, garages or crawlspaces.
• Ventilation system controls shall be labeled and the home owner shall be provided
with instructions on how to operate the system.
• Combustion appliances shall be properly vented and air systems shall be designed
to prevent back drafting.
The wall and openings between the house and the garage shall be sealed.
• Habitable rooms shall have windows with a ventilation area of at least 4% of the
floor area.
• Mechanical systems including heating and air conditioning systems that supply air
to habitable spaces shall have MERV 6 filters or better.
P. Air inlets (not exhaust) shall be located away from known contaminants.
• Air moving equipment used to meet either the whole -building ventilation
requirement or the local ventilation. exhaust requirement shall berated in terms of.
airflow and sound.
a. All continuously operating fans shall be rated at a maximum of 1.0 sone:
b. Intermittently operated whole -building ventilation fans shall be rated at a
maximum of 1.0 sone.
c. Intermittently operated local exhaust fans shall be rated at a maximum of
3.0 sone.
d. Remotely located air-moving.equipment (mounted outside -of habitable
spaces) need not meet sound requirements if there is at least 4 feet of
ductwork between the fan and the intake grill.
• A minimum intermittent ventilation airflow of 100 CFM is required for the kitchen
range hood and a minimum intermittent ventilation airflow of 50 CFM is required for
the bath fan.
Page 4=74 Building HVAC Requirements - Indoor Air Quality and Mechanical Ventilation
Page 4-75 Airflow Rating
From ASHRAE 622-2007
Section 7.3 Airflow Rating
The airflows required by this standard refer to the delivered airflow o/ the system as
installed and tested using a Row hood, flow grid, or other airflow measuring device-
Afternabvely, the airflow rating at a pressure of 0 25 in- w -c. may be used, provided the
dud wring meets the prescriptive requirements of Table 7.1 or rnanufadurers' design
Compliance with the ventilation airflow requirements for a ventilation system can
be demonstrated in one of two ways:
1- The ventilation system can be tested using an airflow measuring device
after completion of the installation to confirm that-" delivered ventilation
airflow meets the requirement- The bulderfnstafler must also fist the resin
of the airflow measurement(s) for the ventilation fan(s) on the installation
Certificate (CF-0R-MECH-05) for the building. The ventilation airflow must
be measured and reported for any/all ventilation system types installed in
the building. except for those described in Rem 2 below.
2- S-imple exhaust systems can comply by performing and documenting an
inspection of the installation to verily conformance to a prescriptive
requirement that the fan has a certified airflow rating that meets or
exceeds the required ventilation airflow, and the duds for the ventilation
system meet either the fan manufacturers published dud design
specifications, or the prescriptive dud design requirements given in Table '
4-9 below (Table 7-1 of ASHRAE 62.2)- The builder/nstaller must also fist
the description of the installed fan equipment and duct design criteria for
the ventilation fan(s) on the Installation Certificate (CF-6R-MECH-05) for
the building.
The fan's certified airflow rating must be based on tested performance at
the 0.25 inch w -u~ operating point- The certified airflow rating of a
ventilation device is generally available from the mannrfacturef, and is also
available for hundreds of products in the Home Ventlating institute (FM)
Certified Products Directory at the H1fl websle ivnw.tnri-;*rr_.).
Manut3clurers can choose whether to provide the certified data for posting
at the HVl website, but all of them should have available the rated data at.
025 indies of water column static pressure.
H the manufacturers dud system design specifications are utilized for
compliance, the enforcement agency may require that the manufacturer's
published system design documentation be provided for use in inspection
of the installation(s)-
The prescriptive dud design criteria given in Table 49 provide maximum -
duct tengtf'ns based on various dud diameters and dud type_ As can be -
seen, the higher the flow, the larger in diameter or shorter in length the
dud has b be. Also note that smoolh dud can be used to manage longer
duct nuns, lnteipolation and extrapolation of bible 4-9 (cable 7.1 of
ASHRAE 622) is nil ate- For akflow values not fisted, use the next
higher value The table is not applicable for systems with airflow greater
Om 125 cf n at 025 inches of water cohmm static pressure.
Table 4-9- PiescrW&e Dud Siairg for Sr gk- Fan Exhaust S (ham 62_Z Table 7. f)
Duct Type . Hex Dud Sascotti Doc t
Fast Raen9
irL WX-) 50 W100 125 50 so 100.125
Diameter Maidrrttiirn lerigtl► R
titch • .
3 X X X X 5 X X X
'4 70 3 X X 105 35 5 X
5 Nit 70 35 20 NIL 135 85 55
6 NL K 125 t 95 NL NL NL 145
7 and above N NL • N. NL N- N- NL N-
Ibisfable assumes no elbows Dedxt 15 t3eEt of allowable dud length for each elbow-
NL
lbowNIL = no nicht on dud length of ttds size -
X = not allowed, arty WmA of dud d Vis size wdh assmied kms and lilting will exceed the rated pressure
drop-
J
ASHRAE Standard 62.2 Made Simple
Whole House (Continuous) Ventilation Requirements
Whole House or Continuous refers to providing a consistent level of ventilation throughout the day in order to remove indoor air
pollutants of all types. The maximum sound level is 1.0 Sones. To determine the cfm requirements for whole house or continuous
ventilation, ASH RAE provides a simplified* table (A) based on size of the home and number of bedrooms. The cfrn levels in the c
can be met by testing the installed ventilation devices for actual airflow or simply using the certified ratings of a fan at 0.25' stati
pressure assuming a proper duct size is used. The minimum duct diameters are listed in Table B and show that 6' ducted fans are
acceptable choice for all installations. It is only acceptable to use 4' duct for installations using a 50 cfm fan or an 80 cfm fan wl
duct length is 3' or less without bends.
TABLE A
Mor Area (fid
0-1
2-3
Bedrooms
4-5
6-7
>7
<1500
30
45'
60
75
90 -
1501-3000
.45
60
75.
90
105
3001-4500
60
'6
90
105
120
4501-6000
75
90
105
120
135
6001-7500
90
105
120
135
150
7500
105
120
135
150
165
Requirements are minimums and assume continuously running farm
' Table A is dervied from the following formula which can also be used:
CFM = (sq. ft. x .0)) # 7.5 x (no. of bedroom 7)
Note: Larger fans with more cfm are always better to remove steam more quickly.
TABLE B
Duct Type Flex Duct . Smooth Duct
Fan Rating
dm @ 025 in. w.g. 50 80 ]0o 50 80 IN
Diameter, in. Maximum Length, IL
3' X X X 5' X X
4' 70' 3' X 105' 35' S'
6' — 125' oo
Assumes noelbows Deduct 15 H of allowable duct length for each elbow.
— = infinite or unlimited
X = not allowed, any length of duct at this size with assumed turns and fittirn
will exceed the rated pressure drop -
Meet Standard 62.2 Whole House Ventilation Requirements With These Fans From Broan-NuTone
Models in the chart are color -coded to correlate with Table A. Multiple fans are deeded for larger homes requiring more than 90 c -
HVI Certified
CFM 0 0.25'
Description
Broan Model
NuTone Model
Duct
Size
HVI Certified
Sones @ 0.1'
Energ
Star
39
50 CFM Fan
QTXE050
QTXEN050
6'
<0.3
Yes
55: '.
8.0 CFM.Fan...
QTXE9'80..: ..
QTXEN080 . _
6'.'= -
- 03 - .
Yes
55
1 80 CFM SmartSense®-Fan
SSQTxE680IN6'
03
es
S?:
80CFMFari/Frudhr' eii;:LigM:"::: :.
:Q -TX BQPLT.
QTXEN98QFL7
6';.--
,b3,;.,':::;•_::.•
.des_...
55:
80 -CFM Fan'.
QTRE080 .
QTREPJOt;O .
.q......
,0:-:. .::.._
YtBs
55 :. ..
80 CEM FarJFltrorescelA LigFrt -: - :.:..
:QZQ p$OE7 T .;:.
QTRE.ND80FET :..::4'::::
;: :•;. ;..<.:: .:.:'
;Yes: :
67
80 CFM Fan
QTR980
QTRN080.
4'.:
.1-0
No
67 •
80 CFM Fan/Light
Q gaw
QTRN080L
4'
1.0"
No
82
110 CFM-Heater/Fan/Light
Q7X110HFL..
QTXNIIOHFL
6'•
0:9
NO
I 10 CF M.Hultlid Sen3iri Fan
!tY... .. 9..
QT -X- 1'Q :. -
.QTXE.Td110S...'.::6':::
.:0.7.-
90•;
110 GFM Fan .-:... . ...:. ....... ...:
QTXEIIO :.
QT -EN110
6': -.
.
' t/.7.:.:. ::.:
=Yt's•
90"
310 -CFM SiiiarlSeristeeFait:
SSME710._...
-"6'.
0:7
Yes
90:,:._:.-•_,
110 CFM .HumiditySenOnq FanWltioroxentt-ight.
Q~.QTXENI2OSFLT.-6'-"-
0.7•-
-Yes'_.
9 ..• .....110
CFIiA Htimditx Sensing Fait%l ig1iE
.QTXEIWOS
QTXE110SL
QTXENIlOSI�
0.9
No
40 : -= ;;-:::;.':•
.110.CFM FarNFtuotesceitl• ightr. ' . -
QTXE110FLT-
QTXEN-1-I@FLT, •:
6`.> ;
a.T ...
fifes
Local (Intermittent) Ventilation Requirements
Local or Intermittent Ventilation refers to usage such as to remove hunMft from showers or cooking at a.ffki* tt)1rn sound Level of
3-0 Sones. It requires a rating of at least 50 cfm at 0.25' of static pressure and a maximum of 3.0 Sone rating at 0.10 of static
pressure. All models in the above chart (except QTXE050 and QTXEN050) meet the requirement as do the folkwhngc
Bman NuTone
Fans QTXE150, QTR140,QTRE110, QTR110, QTXENI50, QTREN110, QTRN110, HD809T,
QTRE100S, QTR070, HD80, 683, 684 671R, 8832WH, 8832SA
FanUghts QTXE150FLT, QTR140L, QTREIIOFLT, QTXEN150FLT, QTREN11OFLT, QTRN11OL, HD80LNT,
QTR11OL, QTR070L, 744, 744FL, 683L, 757SN 744111T, 744FLNT, 757SNNT, 768CHNT, 769RL, 769RFT
Heater/Fan/Llghts 1100HL, IOOHFL 1765HL,765HFL
B VA
NuTone
www.Broan.com • www.NoTone.com
Broan-NuTone LLC, 926W. State Street„ Hartford, WI 53027 • 800.558-1711
In Canada call 877-896-1119
02009 Broan-NuTone, LLC - Printed in USA - 5109 - 9985 0855
B RAN'
SPECIFICATION SHE[
Broan. SmartSenseO
INTELLIGENT VENTILATION SYSTEM
SSQTXE080, SSQTXE110 & SMSCPLR
Improve air quality throughout the home
automatically and efficiently - a smart solution to
home ventilation.
FEATURES
• Removes pollutants such as house hold cleaners,
VOC's, carbon dioxidelmonoxide, and off -gassing from
building materials, carpets and other furnishings
• Helps remove gases and particles that are not trapped
by any filtration unit
• Program a single control for a ventilation rate to match
the size of the home
• Automatically adjusts total run-time based on square
footage and number of bedrooms
• Optimizes energy usage by monitoring normal fan
operation and adjusting automatic ventilation time as
needed
• Continuously monitors and if necessary, activates other
Broan SmartSense• systems located in different loca-
' tions within the home — day and night
• No control wiring required — controls communicate over
existing home power wires
Uses less than 40 watts during ventilation cycles — in
most installations
• Cost effective and (energy efficient ventilation strategy
• Broan Ultra Silent' fans operate at a barely audible 0.3
(80 CFM fans) or 0.7 Sones (110 CFM fans)
Easy installation of fans in the ceftg, vented to the
exterior using 6 -inch dud
• Up to 10 systems can be combined into an air quality
network
• Meets ASHRAE 62 — related ventilation requirements
Broan SmartSense°' uses WSTEON-,
a powerrut, wireless tame control
tecA►ab9y
r N S T E O N
ENA9LEO
1 REFERENCE
grA
Awe I
MH
W IU
CONTROL PHASE
(Reconvnend COUPLERdeep
'
skele-pn9 (ReconKnerW
deep
elecbicaf box) SWQ"an9
80 CFM FAN (Model QTXE080) electrical box) ,
110 CFM FAN (Model QTXE110)
(see fan spec sheet)
SSQTXE080 SSQTXE110
Contains: Contains:
-1 - 80 CFM Fan 1 - 110CFM Fan
(Model QTXE080) (Model QTXE110)
1- SmartSense Control 1 = SmartSense°Control
SMSCPLR Phase Coupler
Required for multiple systems on opposite electrical
power phases
CONTROL SPECIFICATIONS
Paddle Type:. Rocker action
Color. White Paddle 8 TrirrrFrame
Almond Paddle & Trim Frame included
Conditiorm Indoor, 400 to 104° F. up to 85%
relative humidity
Supply Voltage: 120 VAC +/-10%. 60 Hz. single phase
Max. Load: 480 Watts hncandesc n 13A resistive
Certification: Safety tested for use in USA and
Canada (ETL #3017581) +
Broan-NuTone LLC Hartford; Wisconsin vvww.broan.com MG -558-1711
QTY. REMARKS Project
Location .
Architect
Contractor _
Submitted by Date
80K 990443am
Rev. 08
CERTIFIED VENTILATING'FAN PRODUCTS
Section 1-11 "
MODU
STATIC
MODEL
STATIC '
OR SERIES DETARS
PRESSURE" CFM" SODS
WATTS
OR SERIES
MACS
PRESSURE" CBr
SONES WATTS
QTX110SL
110 0-9
33.5
HLB11
Ver. Ifs+
@ 0.20' SP
1000
@ 025SP
90
33.0.
For. HS+
@ 0.2V SP 1100
O77�p5p
50 <0.3
19.7
SPIN
@ 02V SP
110
@ 025' SP
39
19-2
@ 0.4U SP
97
0TXE080
80 0.3
23.3
SP140
@ 0.20' SP
150 •
_
@ 025.' SP
55
232
@ 0.40' SP
133
QTXE080FLT
80 0.3
23.3
SP200
@ 020' SP
210
@ 025' SP
55
232
@ 0-40' SP
195
Kitchen -
Exhaust Fans
QTXE110
110 0-7
33-5
@-0-25 SP
90
33.0
12C
370
8.0
502
270
8.0
QTXE110FL.T
110 0.7
33.5
503
160
5.0 `
@025 -SP
90 .
33.0
504
350
6.5
505
180
6.5
OTXE11oS
110 0.7
-33-5
506
470
'
8.0
@ 0.25 - SP
90 •
33.0
507
250
7-0
508
270
6.0
QTXE110SFLT
110 OT
33.5
509
180
6-5
@025 -SP
90
33.01
509S
180
63
509SMX
180
6.5
QT)CE150
150 1.4
51.3
L509SM
180
6.5
@ 025' SP
118
50.1
Kitchen Ramie Hoods - Ducted 8 Convertrif*
QTXE150FLT
150 1.4
51.3
@ 025 ' SP
118
50.1
103023
Ver- HS+
360
5.0
Hor. HS+
.360
4.5
SSQTXE080
0.25' SP
80 �� 0-3
---� 55
23-3
23-2
113023
Ver. FIS+
360
4-5
Hm. HS+
360
4.5
SSQTXE1t0 �
110 -� 0-7
33.5
> @ 035' SP
•--� 90
33.0
1Xi042
der. HS*
190
8 S
W. "S+
200
8.5
DowmdrA MAW Exbauskm
153001'
ver- HS*
300
4.5
773003
-500
153002
Ver. HS+
300
4.5
273603
500
153004
Ver. HS+
'300
4.5
X04
500
153023
Ver- HS+
300
4.5
RMDD3604
.500
153601
Ver. FIS►
300 •
4.5
qgp f
5p0
153602
Ver. HS+
300
4.5
153604
der. FIS+
°300
4.5
Nrfgre Fans (afl models)
153623
Ver. HS+
300
4-5
NlI'100
@ 03r SP
110
402101
Ver. FIS+
160
6.5
@ 0.40" SP
98
Hor" FIS+
160
6-5
W140
@ 020' SP
150
402102
Ver. FIS►
160
6-S
'63
'
@ 0.40' SP
141
Her. HS*
160 -
MP200
@62VSP.
210'
402106
Ver HS+
160
6.S t
@ 0.40; SP
200
"N. HS+
160
6.5
MP280
. @ 02lr SP.
290
402401
Vet FIS+
160
6.5
@ W SP
265
Flay. HS•
160
63
HLB3 Ver. HS+
@ 030' SP
260
402402
Ver. HS.
i60
6.5
Har- HS+
@ 020r SP
280
HOF. FIS+
160
6.5
H1B6 W. HS*
@ 020r Sty
600
402401
Ver. HS*
i60
6.5
"Hor- HS+ '.
@02V SP
600
.16. HS*
160
6..5
HLB9 Ver. HS+
@ 020' SP
700
402408
Vel HS+
160'
6.S
Ha. FIS•
@ 020' SP
800
Mi. FIS+
'160.
6.5
• STATIC PNESMW VES
WA7MGAGE PJ. W.G.* Direct Dbdwp
Fans Qton•Dnded) @ 0.03
hr. wig Ducted Fans @ 0.19 bL w S 0.25lir. wg (opdonae'
b*w Fans @ 0.20.6x. w% two aMfiw l (opdorrai) for static pressure
"COITVERSIONS Paspls = in. wg .x 250 tares per Second ph) = dm x W
NUTS CHANGES IN RED ONWATE RECFM IEVMM TO TM HN CEM" NOW VENTIIATWG PRODUCTS DIs?£CiORY/.
U,U _U TITLE 24 INC.
7544 SADDLEHILL TRAIL, ORANGE, CA 92869 • (714) 771-1507 • FAX (714) 771-2939 • T-24@soca)"rr.com
{
•
April 18, 2013
Owner: Foremost Homes
70600 Country-Club Drive
Rancho Mirage, CA 92270 'CITY OF LA QUANTA
BUILDING & SAFEMDEPT.
• APPROVED
Designer:. Kevin L. Crook Architect, Inc.
FOR CONSTRUCTION
1360 Reynolds Avenue, #110on 'j �o l3 .
Irvine; CA 92614
Project: La Quinta Housing Projects '
Plan 1232 - Lot 7 (52390 Avenida Velasco)
La Quinta, California
• Job No. 07057
STATEMENT OF CONFORMANCE'
This Calculation contains all the building features and performance specifications required for
compliance by the California Code of Regulations Title 24, Part 1, Administrative.
'Requirements; Part 6, ' Building Energy Efficiency. Standards; and portions of Title. 20:ZO"" ,
Appliance Efficiency Standards. When these features are incorporated into the architectural'
ry. plans the design will be in compliance with the 2008 Energy Efficiency Standards as they''!.
apply in Climate Zone 15, using MICROPAS8 Version 8.1, a California Energy Commission
approved computer performance method program.
r r _ Prepared By:
A7BErC11 / r 1
California Association of Building Energy Consultants ' ll�ck Maurer
CERTIFIED ENERGY ANA,,LYST ifr--
IVcate NoEnergy Plans Examiner
Rick MaurerEEQ. R08-88-1601 and NR08-88-3583
R08-90-243 & NR08-90- iT California State License No. 502290 C20
APR 2.6 2013
CITY OF LA QUANTA
- COMMUNM DEVELOPMENT
** SUMMARY SHEET **
Project: Foremost Homes -- La: Quinta; CA Zone: -15
r
La Quinta Housing Projects
Plan 1232 - Lot 7 (52390 Avenida Velasco)
Wall -Insulation: R-21 (Min. 2X6 Exterior Walls Required)
Ceiling Insulation: R-21 Below Furnace Platform and Catwalk
R-38 Typical,
Radiant Foil Barrier: Required @-Roof o/Conditioned Space &Attic Gable Ends
(Requires an Emittance of 0.05 or less)
Raised Floor Insulation:" N/A
Slab, Edge Insulation: ' . None
Glazing Type: All glass is DUAL PANE with High Performance. Low -E Glass. (See Notes)
Hard Surface Flooring:.. None Required
Minimum Furnace AFUE: 80% AFUE
Minimum Heating Capacity: . 20,152 BTUH
Minimum A/C SEER: 13.0 SEER/11:0 EER Rater Verified
A/C Tonnage:. Min,Sens.=14,763 @ 115° (A/C Size By Mechanical Contractor)
Duct Insulation: R-6.0 For Ducts & Plenums in Unconditioned Spaces
(Duct. Leakage Test Required)
Note(s):. 1) This house will have a` tankless water heater with an energy factor of .82 or
greater and -200000 BTUH or less.
2) All windows and glass doors will have non-metal frames with a weighted
average NFRC U -factor of .35 or less and a weighted average SHGC of .25
or less with high performance Low -E, (Max) glass.
Prior to final inspection, a copy of the following checked installation certificates shall be
posted or made available with the building permit(s) issued for the building and shall be
made available to the enforcement agency for all applicable inspections -
Installation Certificate
CF -6R -ENV -01 - Env - Insulation; R ; Fenestration
CF -6R -ENV -20 -HERS - Builkling Envelope
CF -6R -ENV -21 -HERS - Quality Insulation Instalatidn Qll - Framing Stage Checklist
CF -6R -ENV -22 -HERS - Quality Insulation krstaflatiorr Qq - Insulation Stage Checklist
CF -6R -LTG -01- Residential LightiM
CF-6R-MECH-01 - Domestic Hot Water D
CF-6R-MECH-02 - Solar Domestic Hot Water Systeffis SD
CF-6R-MECH-03 - Pod And Spa Heating Systeim
CF-6R-MECH-04 -.Spam Conditioning Systems, Ducts and Fans
CF-6R-MECH-05 - Indoor Air Otiafity and Mechanical Ventilation
CF-6R-MECH706 = Evaporatively EvaporativeCooled Units
CF-6R-MECH-07 - Evaporative Coolers
CF-6R-MECH-08 - Ice Storage Air Condrtioni [SAC Units
CF-6R-MECH-20-HERS - Duct Leakage Test - Completely New or Replacement Duct Sys"
CF-6R-MECH-2 I -HERS - Duct Leakage Test - Existing Duct System
CF-6R=MECH-22-HERS - HSPP/PSPP Installation; Cooling Coil Airflow & Fan Watt Draw Test
CF-6R-MECH-23-HERS - Verification of High EER Equipment
CF-6R-MECH-24-HERS - Charge Indicator Display CID
CF-6R-MECH-25-HERS - Re ant Charge Verification - Standard Measurement Procedure
CF-6R-MECW26-HERS - Refrkjerant Charge Verification - Alternate Measurement Procedure
CF-6R-MECH-27-HERS - Maximum Rated Total Cooling Capacity
CF-6R-MECH-28-HERS - Low Leakage Air Harder Verification
CF-6R-MECW29-HERS - Suppty Dud Compliance Credits - Location; Surface Area; R-rak e
For installations that require HERS field verification, registered copies of the following
checked verification and testing certificates shall be posted or made available with the
building permit(s) isstyed for the building and shall be made available to the enforcement
agency for all applicable inspections.
Certificate of Feld Verification and Diagnostic Testing
CF-0R-ENV20- EMIding Envelope Seals
CFAR-ENV 21- Quay Insulation Installation QII Framing Stage Cheddist
CFAR-ENV-22 - Quarity Insulation Installation QII - Insulation Stage Checklist
CFAR-MEGW20 - Dud Leakage Test - Corripletely New or Replacement Dud System
CFAR-MECH-21- Dud Leakage Test - Exisft Dud System
CFAR-MECH-22 - HSPP/PSPP Installation; Cooling Cal Akfbw & Fan Watt Draw Test
CF-4R-MECH-23 - Verification of High EER Equipment
CF-4R-MECH-24 - Charge Indicator D' CID
CFAR-MECH-25 - Refterant Charge Verification - Standard Measurement Procedure
CF-4R-MECH-26 - Not Used
CFAR-MECW27 - Maximum Rated Total Cooling Capacity
CFAR-MECW28 - Low Leakage Air Handier Verification
CFAR-MECH-29 - Supply Dud Compliance Credits - Location; Surface Area; R-vahje
Mandator 'Measures Summa MF -1R
Residential (Page 1 of 3
Site Address: Enforcement Agency: -7 Date:
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed,
regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -IR,
CF -IR -ADD, or CF-IR-ALTForm) shall supersede the items marked with an asterisk(*) below. This Mandatory Measures
Summary shall be incorporated into the permit documents and the applicable features shall be considered by all parties as minimum
component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all
applicable sections of the MF -IR Form with plans.
DESCRIPTION
Building Envelope Measures:
§116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient
SHGC , and infiltration that meets the requirements of § 10-111 (a).
§117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
§118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §1 18(i) when the installation of
a Cool Roof is specified on the CF -IR Form.
*§I50(a): Minimum R-19 insulation in wood -frame ceiling or equivalent U -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§150(c): Minimum R-13 insulation in wood -frame wall or equivalent U -factor.
*§I50(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor.
§150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form.
§I50(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§ 150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no
eater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150(e)I A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped
with a with a readily accessible, operable, and?tight-F)tting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the
building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve,
backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 113(c)5.
§ 115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an
electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters.
§ 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
§ 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)IA: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
§ 1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12
external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
§ 1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections
of hot water pipes are insulated per Standards Table 150-B.
§ 15%j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank
shall be insulated to Table 150-B and Equation 150-A.
§ 1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A.
§ 15CQ3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space.
2008 Residential Compliance Forms August 2009
Mandatory Measures Summa MF -1R
Residential (Page 2 of 3
Site Address: Enforcement Agency: Date:
§1500)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
Ducts and Fans Measures:
§150(m)]: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602,
603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or
enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable
requirements of UL 181, UL 181A, or UL 18113 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to
seal openings ter than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)l: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal,
duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts.
Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts.
§ I50(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape
is used in combination with mastic and draw bands.
§150(m)7: Exhaust fan systems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that
can cause degradation of the material.
§150(m)10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in
Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in
Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§ 114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations;
an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use
electric resistance heating ora pilot light.
§114(b)l: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return
lines, or built-up connections for future solar heating
§I 14(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§1 14(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
§150(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p).
Residential Lighting Measures:
§150(k)l: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in
Table 150-C and is not a low efficacy luminaire as specified by § I 50(k)2.
§150(k)3: The wattage of permanently installed luminaires shall be determined as specified by §130(d).
§I50(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high
efficacy lamps meeting the minimum efficacies contained in Table 150-0 and shall not contain a line -voltage socket or line -voltage
lamp holder, OR shall be rated to consume no more than five watts of power as determined by § 130(d), and shall not contain a medium
screw -base socket.
§150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
§150(k)7: All switching devices and controls shall meet the requirements of §I50(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanent installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 W or 100 watts for dwelling units larger than 2,500 fl? may be exempt
from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high
efficacy.
2008 Residential Compliance Forms August 2009
I
lndatory Measures Summary MF -1
idential (Page 3 a
address: - Enforcement Agency: Date:
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they. are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
- manual -on occupant sensor.
§150(k)ll: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility
rooms shall be high efficacy luimnaires.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch
that complies with the applicable requirements of §119, or by a manual -on occupant sensor that complies with the
applicable requirements of 4119.
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply
with § 150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or
other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then
2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing
and ceiling.
§150(k)l3:.Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling
units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot
shall be high efficacy.
EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual
on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the
following controls: a photocontroi not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an
energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be
always on
EXCEPTION 2: Outdoor luminaires used to comply with Exception] to § I50(k)l3 may be controlled by a temporary override switch
which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six
hours.
EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of
the California Electric Code need not be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five
watts of power as determined according to §130(d).
§1 50(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in
Sections 130, 132, 134, acid 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of
Sections 130, 131,134, and 146
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-ris%residential buildings with four or more dwelling units
JI
shall be high efficacy luminaires.
EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s)
certified to comply with the applicable requirements of § 119.
2008 Residential Compliance Forms August 2009
L., CERTIFICATE OF"COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 1
Project Title.........
.Foremost Homes -Plan 1232. Date..04/18/13'11:48:52
Project Address ........ :.52390 Avenida -Velasco ******
La Quinta, California ' *v8.1*
Documentation Author... Rick Maurer ******. Building Permit•#
Rick Maurer•,Title•24, Inc., y
F 7544•E Saddlehill Trail Plan Check./ Date
'
Orange,,CA 92869.
• 714=771-1507 Field Check/,Date
Climate Zone.-....'....... 15 '
Compliance Method.:...... MICROPAS8 v8.1 for 2008 CEC Standards(r03) -
• MICROPAS8 ENERGY USE SUMMARY -
Energy'Use Standard Proposed, Compliance-, Percent
i
(kTDV/sf-yr) Design Design Margin Improvement
Space Heating..`' 2".87 2.97 -0.10 -3.5
Space Cooli'ng...'.: '.72.62 77.76 -5:14 -7.1%
,Ventilati.on'Fans ::... 1.05 1.05' 0.00. 0:0%
Water Heating..?' 22.06 13.96 8.10 36.7%
� otal 98.60 95 74 2 86 2'.9%
T
�: • 9 Pp,
� � *** Bu�.ldm 'complies ith Com terr�Performance *��*
' �,��`� ***-�ERS�,tVerifica�on Requiredfor' Cho plian e *�**' �� - •
:
ARE
f cGENEI2AL INFORMATIONQNS `�
yxt�<s„!• '''a iv''b%"Ssyw Tfat" . s,., A.` .-t ' , -C' r; t" '4� a xz � "V e + .. _
, • r ` - .... °K. ',fn't..i• r rah Y LSC" - ..r�xif_'i.:r.. �%iiwit. . .,.�.... , =- .._ ....
I
HERS Verification.........:' Required
x}ws Conditioned Floor Area..... 1232 sf
Building Type..... ...... Single Family Deoached
Construction Type .'New
Natura•1`,Gas at Site ....t... Yes
• �.. Building` Front Orientation. -Front Facing 270 deg (W)/ -
'Number of• Dwelling Units... .l = ,
Nuinber -of Building Stories. 1
• Weath'e'r Data Type.........FullYear, '
Floor Construction Type.... Slab On Grade ,4
Number of Building!Zones... 1
. Conditioned Volume..:: 9856 cf '
-Slab-On-Grade Area......... 1232 sf..
Glazing Percentage..... 11.9 % of floor area
Average Glazing U -factor... 0.35 Btu/hr-sf-F;.'
Average Glazing SHGC........ 0:25
' Average Ceiling Height...... 8.ft
Reg: 213-N0023104B-000000000-0000• Registration Date/Time: 2013/04_/18 15:12:14 HERS Provider: Ca10ERTS, Inc
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 2
,Project Title.... Foremost Homes -Plan 1232 Date..04/18/13 11:48:52
MICROPAS8 v8.1 File-FOREMOST20 Wth-CTZ15SO8
User#-MP0357 User -Rick Maurer Title 24, Inc ,Run -Plan 1232 - Lot,7
.•BUILDING ZONE INFORMATION• ^'
-� Floor # of # of Cond- Thermo-- Vent -Vent Verified
Area Volume Dwell Peop-. it stat Height Area Leakage or
►.. `Zone Type (sf) (cf )' "Units,, le ioned . Type . (ft) (sf) Housewrap
•Residence 1232 9856 •, 1.00 4.0 Yes Setback' 2.0*Standard No
_.s ATTIC AND ROOF DETAILS _
Frame R- R-
Roof •Roof Re- Emiss- Frame Spac- ,Value Value -Vent
Mass -"Rise flect- ivity Depth ing Above Below Area Vent
Roof Type (lb/sgft) ance. - (in') (in.). Deck Deck Ratio High
Tile Heav:y`t •t : 4 12 t0.10 0.85 3. 5 ' 24 'oc 0.00 0.00 -1/300 0:30
• _ iib- : • • � ' • • ' - "` .
OPAQUE SURFACES
U= Sheath- Solar Appendix
,-
Frame Area fact- Cavity ing Act Gain's,. ,JA4 Location/ '
Surface ' Type(sf) or R va R val Azm Tilt Re erence Comments'
0 a
1 WilWood ��16 0 069 21' 0 270 90 Y"43�A6' Front 2x6 Wall '
at
` 2 Wall Woocl72 0' 069 2s1 O z �27s0� 90 No Y,4 3 A6 Gar. 2x6; Wa11
3 W11 3 0 0 6 9 �0 J 90" OYe s 4 3 �1 Rik fit 2
4 ;Wal.l Woody 191 0 069 1 0 r 90��X90 Yes 4 3 1 A6 Bac'k�2Sx6`'Wa11
5 GTalfv Wdocihfi P 3`Q4�0'069�1�G� 180�9�O�Ye's 431 Of
Riht'�2x6~Wall
+s. `+C. o1 •i t h - t� g • . .
6 AtticRad :..;Wood :1162 _O .02;5>.,._38 -- . 0 nJa ` 'U'Yes 9 2=i 1 A21 Vented Attic
7 At�tt cRad Wood 70.043, 21 0. n '0 Yes 4.2.1 A17 FAU Platform
8 Door, x Wood 20 0 .500 -0 0 270 90 Yes 4.5.1 A4 -Front `Door r
e
- � PERIMETER LOSSES + • •
._- Appendix
Length l•�' F2 Insul Solar JA4 - Location/ a
Surface ' (ft) lFactor R-val Gains Reference Comments
9 S1abEdge 144" `0.73.0 - R-0/Oin No 4.4.7 Al Standard S1ab.Edge
Reg: 213-N0023104B-000000000-0000 'Registration Date/Time: 2013/04/18 15:12:14 HERS Provider: Ca10ERTS, Inc
CERTIFICATENOF`COMPLIANCE: RESIDENTIAL COMPUTER�METHOD CF-JR ;SPage'•3
Project.•Title,. F ,Foremost Homes-Plan 1232 Date'., 04/18/13 11�:48:52 F
" MICROPAS8 v8.1t:File-FOREMOST20 Wth-CTZ15S08
�� User#-MP0357,• User-Rick'Maurer Title,29;..Inc Run-Plan 1232 Lot;7
�.
FENESTRATION SURFACES , �, .�/a'1�D�•�!�"
-Exterior + f F
` + Area , U- Act, • `Shade -'. �E.
Orientation, - (sf) factor-SHGC1•Azm Tilt Type �. Location%Comments':,
1 Wind Front '(W) 16:0 0350 0.250 270 90 Standard. 'FGLASS2'• +i" ,✓/�n,�
2 Wind Left ; (N) 9..0 0,. 350' 0..250 - 0 90j Standard L'GLASSI
'3. Wind ,Left (N) 20..0 0:350.,0.250 0 90, Standard LGLASS2 W �
4 Wind Left: (N)er .2,0,..0 0.350'.,0:250 0- 90 Standard LGLASS3
5 Door Back +(E) 33,.4',0..350 0:250 ,90 90, Standard BGLASSI,`
6 Wind Right (S) 20.0 0-.350'0.250 180 90 • Standard.•RGLASSI
7 Wind••Right.' (S)' 12.0 0..350•-0.250''180 90. -Standard RGLASS2:.
8 Wind 'Right '(S) 1,6.0 .0..350 .0:25,0 180. 90.' Standard.'RGLASS,3.�s �,
OVERHANGSi ? s ♦`,t
t ► ,X.
—Window— Overhang
,A'rea - , ., Left Right
.Y1-
Su'rfaze (sEf ); .Width "Height Depth Height •Extens`ion Extension,
{t: _ , t
1 Window 16 0 n/a 4 0 0 8 4`0 a/a a`
Wiow F1
90n%a� 0 �0 1
•°` 3Win�dow X20 0 n'/;a �3a i101 0���
._Wa 3 0' 1 0 10a�n/aiV1-
t5 •Doo,3- n/a 6 7=_ 0 8 50 ja
6 Wndow 2 0 0N/ !Ca
� /`a NMI*
�.- a
8 _Window 1-61 09l n/a .4' 0 _,� 1 0._,._ ... 1 °pr.:= ..-...n./a n/a:'
''' SLAB,YSURFACES".. it Y„,;
t , - +
)_Area. ,-, a # ' .+ •.
{' r •r Z : `Slab Type },(.5f)'
' -Standard Slab •1232 . , ;;
HVAC,SYSTEMS a
,` * ” ' r • �::•,' ,;' Uer'ified 6
'i.
'Verified Verified. Verified Verified.Maximum',
System �,'Minimum �.`. Ref rig ,Charge Adequate Fan Watt•Cooling` '
♦r
Efficiency EER or CID "` Airflow 'Draw Capacity.. .
`Furnace 0:800 AFUE n/a n/a n/a n/a - n%a -
ACSplit 13:0.0:. SEER 11 , 0 No '. No . i 'No ; 'No
i c r ,
•Reg.'213-N0023104B-000000000-0000 Registration* Date/Time:.2013/04/18 15 12:14., HERS.Provider:'Ca10ERTS,'Inc i
• N
HVAC SIZING : y. fr ,•
` �,! r ;fit .. :•. �, •7 - .
- a , Verified ,
Total'- Sensible Design ".r .-Maximum' i
§ •r ,`L '' :' Heating Cooling • Cooling 'Cooling,,
'Sys -tem 1 aLoad-' Load. Capacityl' .Capacity _
"Type ° (B'tu/-hr) (Btu/hr) `.(Btu/hr) (Btu/hr).
•20152 n/a ti rn/a, t. n.
/a y
s AC -Split n/a 14763'• 18321 n/a `
'Sizing 'Locati.ori.. i ' { LA QUINTA .L Y
,Winter Outside. Design.>26 F �.
Winger, Inside"Design..`. �r70'.F
'.Summer Outside Design. "x{. 111 F-
Summer.Ihsi•de Design....", x.75 F
_ 1
j Summer ;Range .. 3 4 F
.'DUCT "SYSTEMS'
1
:. , +Verified Verified Verified
stem r -Duct uct Duct Surface Buried ;i
w
". Type Loc'`�aio�nRmvlue Leakage Are�'?Ducts `
5
L ` Furna-c '' x` �At —;kc : R46 r Yes No . i N'o
y 5
Yes No
n
t4�
' .�• � K� }`.�"''�a � 1�
•t' - 4 , sn.'.?```:4.-
r
,. ti Flow Power ,
Systema Type •.(`cfm)`
1' e'
.. '• :'AL —
Standard 42 32 25-
,
+.'
WATER. HEATING SYSTEMS
; , a .
Number Tank External 9
Heater i, in —Energy Size Insulation
Tank Type Type -.,.Distribution' Type,' ','System Factor ,.(gal) R -value
1 1 Small`Instanta,.Gas StandardNoIns.ui 1 .82' ' n/a, R=n/a '
+ • . OM1' :' ,N v •; •i• � � ,. , 'x � : `" ,:. r 1• ,
Reg. 213-N0023104B4000000000-0000,, Registration Date/Time;.2013/04/18 1512:14 `HERS Providero.'Ca10ERTS,1Inc
s
i.
I 5.
Y
ms.µ ', t..
i',.
a�•f
a
••� .L
"COMPLIANCE:
.,
• `CERTIFICATE .OF
RESIDENTIAL 'COMPUTER .METHOD'
> w
CF 1R 'Page 4 .
• r.` prn1P!"t- T9't•1 i.
- - . u--rnrcn•inat Hnmca—A1 nn 1 717
..-?T1�Yc
fld'/1 P /1 Z 1 l�r AQ =yS'7 .
• N
HVAC SIZING : y. fr ,•
` �,! r ;fit .. :•. �, •7 - .
- a , Verified ,
Total'- Sensible Design ".r .-Maximum' i
§ •r ,`L '' :' Heating Cooling • Cooling 'Cooling,,
'Sys -tem 1 aLoad-' Load. Capacityl' .Capacity _
"Type ° (B'tu/-hr) (Btu/hr) `.(Btu/hr) (Btu/hr).
•20152 n/a ti rn/a, t. n.
/a y
s AC -Split n/a 14763'• 18321 n/a `
'Sizing 'Locati.ori.. i ' { LA QUINTA .L Y
,Winter Outside. Design.>26 F �.
Winger, Inside"Design..`. �r70'.F
'.Summer Outside Design. "x{. 111 F-
Summer.Ihsi•de Design....", x.75 F
_ 1
j Summer ;Range .. 3 4 F
.'DUCT "SYSTEMS'
1
:. , +Verified Verified Verified
stem r -Duct uct Duct Surface Buried ;i
w
". Type Loc'`�aio�nRmvlue Leakage Are�'?Ducts `
5
L ` Furna-c '' x` �At —;kc : R46 r Yes No . i N'o
y 5
Yes No
n
t4�
' .�• � K� }`.�"''�a � 1�
•t' - 4 , sn.'.?```:4.-
r
,. ti Flow Power ,
Systema Type •.(`cfm)`
1' e'
.. '• :'AL —
Standard 42 32 25-
,
+.'
WATER. HEATING SYSTEMS
; , a .
Number Tank External 9
Heater i, in —Energy Size Insulation
Tank Type Type -.,.Distribution' Type,' ','System Factor ,.(gal) R -value
1 1 Small`Instanta,.Gas StandardNoIns.ui 1 .82' ' n/a, R=n/a '
+ • . OM1' :' ,N v •; •i• � � ,. , 'x � : `" ,:. r 1• ,
Reg. 213-N0023104B4000000000-0000,, Registration Date/Time;.2013/04/18 1512:14 `HERS Providero.'Ca10ERTS,1Inc
s
" CERTIFICATE{OF'COMPLIANCE: RESIDENTIAL',COMPUTER METHOD CF -1R• -P g6'5
}
Project Title. Foremost Homes -Plan 1232` 'Date. .04 18/13-11-:48:52
t
• SPECIAL FEATURES AND, MODELING ASSUMPTIONS'
**.* Items iri this section'*should be documentedron' the plans,
i***� installed to manufacturer and CEC specifications, and.
***`verified'during plan check and field inspection.
This;building.incor.porates, a Radiant,Barrier: E
This, buil"ding'.rincorporates a • non-standard' Water Heating System -t
`'.HERS REQUIRED•VERIFICATION.
Items :in ,th'is" section,require. field'testing arWor ***
verification by'Yar certified home energy rater. ,under***
*** the supervision of -"a CEC-approved'.,HERS..provi der using *** l•.
*** 'CEC;Rapproved testing: and/or verification methods and
*** must be; eported on. the CF -4R: -installation` certificate.`
This bulding+iricorporates HERS .verified High :Energy Efficiency Ratio (EER):
This building incorpo a tessHHERS v�errii -ied Duct Leakage .F Target-'leakager is
calcul �ated�and .document.e°dtiontheCF 9lR�` zIf the meu ;e��CF.Mis?above the • •.
�r i5.:. c r c 1a l E la3 ; r13
tar•.et�the�ncor ecti�oeaetioimustabe-:ta to reduce "the�ductleakage and.,
th must rbe re est,t-,9V Alternatively;. the zcompl+isance calculations could be ,.k
sig#+ es x u
re nen,withou'��uct testing If ducts are not instCFO11 U then�HE
I mtt 4 '!*c r rf r i p r V
C ver�f> eat doh is�ro��
3.i '�'3r aX,Sbi: �'•`� �`• x i - .x��' _ -" _ . -
z
1�
REMARK
.�-.��� '& .. - a o • � ,
1) This' house' will have a` tankless ,water :he
Ae'r with an? energy
` factor of 82 r' greater and :2-00000 mBTUH or: less' . "'
2) All •windows ard..'glass' doors will have non=metal frames t {.
with•, a weighted;. aperage •NFRC+ U -factor..' of 35 ,or less; and a
weighted. average.SHGC'of_`'.25 or .less with high performance r^
• Low -E :'(Mak) glass.:Sk
r `. r '•
'r
Reg: 2137N0023104B-000000000-,0000; Registration Date/Time:•2013/09/18'15:12:19r �HERS Provider: Ca10ERTS„ Inc
y
CERTIFICATE:OF,COMPLIANCE:;RESIDENTIAL'gCOMPUTER,METHOD �` CF-1R ',Page 6.
Project 'Title.,Foremost Homes-Plan 1232_ bate.:04'/1'8/13'11:48.-52*
•MICROPAS8 v8.1 File FOREMOST20,, Wth-CTZ15S08 ;
,,User#-MP0357 User-Rick-Maurer Title 24, /Inc Run-Plan 1.232 - L`ot7 "
COMPLIANCE STATEMENT
This certif.icate:of,compliance lists $,therbuilding'features•a_nd performance
specifi:cations• •nee'ded "to comply,with Title-24;' Parts 1''•and- 6 of {:the
California ' ;Code"..' Regulations,, and the' '•administrative reg`ulations': to
-"•implement :them: This. certificate has•'beeh ,sIgned •by, the ',individual ''With '
overall" design 'responsibility-.
l4
# ` DESIGNER or.OWNER DOCUMENTATION AUTHOR
Name �. Name ...... Rick:Maurer,
Company, Foremost�Homes. Company:, Rick 'Maurer Titley 24; Inc.
Address 70600, Cour►try`Club•Drive Address. 754.4 E' Saddlehill Trail
• _,,La Quinta, , CA 92270 Orange, CA -92869 '
Phone..,. (760.) 537=„1502 -Phone, -714-771=1507' f
,`.signed.', iR { ? . .t " si•gn`ed
.. n, ('date) - '`(date)
e _ fENFORCEMENT\, AGENCY.'
' Name "at �` a i.. "•`% "^' `F ++ fi� " �P9�'3 x''v
,. T'lt�l#e�"�` u°z`'�?. .i���� fl��''3�a t�) � - ra4 i �l"t•
Age,�riteY • �� �
M1 �d.��. 6�.,'w,c'�' 1y�Y%S 1 4sd'z� 3. � ��,}j"'a� y �. {.y.-.. •41td'�-. , h.(3 ...
.s I
Phone ,�.� �` _,n••� ,.�, ^ � ,� -� r ;�}
S +C rN "9i.;*0loamL
_ `"'t`'..i*,,,,r �'�§M1 1„d t i'c t� 'f`..•As 'l. i"'.-. - r, ... /.+
Signed`
(date) �� 'y`, f ; �. _ , =`. • "+' `• ; , �,
..' � , i•` , � - is I .. •
Electronically Signed `at,'Ca10ERTS:coin by.James Fortson, (ForemostkHomes)•4/18/2013
Elect'ronically'Filed:by Rick Maurer,and Authenticated at-Ca10ERTS.cOm'- 4/18/2013'
,Reg: 213-N0023104B-000000000-0000,,kegistration, Date/Time': 2013/04/18 15:i2:14 HE Provider:.Ca10ERTS; Inc
HVAC SIZING...,+
HVAC, Page 1
Project Title... .....•.Foremost Homes -Plan 1232 Date..04/18/13.11:48:52
Project Address.._.......52390 Avenida Velasco ******
La Quinta, California *v8.1*,
Documentation Author... Rick Maurer ******°'
Building Permit #
'. --Rick Maurer Title. 241- Inc.
7544 E Saddlehill Trail.
Plan Check"/, Date
Orange, CA 92869
' 714-771-1507
Field Check/ Date
Climate Zone.......... 15
Compliance Method...... MICROPAS8.v8.1 for 2008•CEC Standards (r03)
MICROPAS8 V8.1. File-FOREMOST20 Wth-CTZ15S08
User#-MP•0357 User -Rick Maurer Title24, Inc -Run -Plan 1232 - Lot 7
GENERAL INFORMATION
Floor Area., ............... 1232 sf
Volume. ......:... ...... 9.856 cf
Front Orientation; ........... Front Facing
de (W)
deg -(W)
' �•
Sizing Location ............. LA QUINTA
Latitude..... ..... ...... 33.8 degrees
Winter Outside Design...... 26 F
' Winter Inside Design....... 70 F
Summer, Outside Design...... 111, F ,
Summer Inside Design....... 75 F
Summer Range.......... .. 34.F '
• Interior Shading Used...... Yes
Exterior°Shading Used....:. Yes
Overhang Shading Used.....,.. Yes
Latent Load Fraction..... 0.2-4
HEATING AND COOLING LOAD SUMMARY
"
Heating
Cooling '
Description :(Btu/hr)'
(Btu/hr)
Opaque Conduction and Solar...... 11122
4659
Glazing`Conduction and Solar..... 2255
.2999
Infiltration..... .............. 4006
2316
Internal Gain............ .....y n/a'
2520
Ducts...... .................. 2769
2269
-SensibleLoad...:......."....:.... 20152
14763
Latent Load........... .. ..... n/a
3558
Minimum Total Load 20152
18321• -
Note: The Toads shown are only one of the criteria affecting the selection
of .HVAC equipment. Other relevant design factors such as air 'flow
requirements, outside air,'.outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
POST IN A CONSPICUOUS PLACE
Certificate of Occupancy
Community Development Department
This Certificate is issued pursuant to the requirements of Chapter 1 Section R110 of the
California Residential Code, certifying that, at the time of issuance, this structure was in
compliance with the provisions of the Building Code and the various ordinances of the City
regulating building construction and/or use.
BUILDING ADDRESS: 52-390 AVENIDA VELASCO
Use classification: SINGLE FAMILY DWELLING Building Permit No.: 13-0543
Occupancy Group: R3 Type of Construction: VB Land Use Zone: RC
Code Edition: 2010 Sprinkler Installed: YES Sprinkler Required: YES
Owner of Building: FOREMOST HOMES LLC
Address: 70600 COUNTRY CLUB
City, ST, ZIP: RANCHO MIRAGE, CA 92270
_____________GREG BUTLER__________________ By: AJ ORTEGA
Building Official Date: MARCH 20, 2014