05-0007 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
.LA QUINTA, CALIFORNIA 92253
Application Number:
0:5=-0=0.0;0.0007
Property Address:
• -; >.:.,
5294`5 AVENIDA VELA — .
APN:
X773 -325=028 -13 -000000 -
Application description:
ADDITION - RESIDENTIAL
Property Zoning:
COVE RESIDENTIAL
Application valuation:
189075
Applicant: Architect or Engineer:
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
--------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Busi and Professionals Code, and my License is in full force and effect.
License Class: B C8 License No.: 796375
Dite: Con actor:.
frr
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
.permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing. with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ ). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
.7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
-property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.l.
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.I.
Lender's Name: _
Lender's Address:
LQPERMIT
Owner:
FRANCO JAMES
52-295 AVENIDA VELASCO
LA QUINTA, CA 92253
Contractor:
FRANCO CONSTRUCTION,
85188 AIRPORT BLVD
THERMAL, CA 92274
(760)399-9765
Lic. No.: 796375
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 7/12/05
------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier CLAREDON INS Policy Number 03KR0027383
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I s,pdGToTtNome sub' ct to the workers' compensation provisions of Section
3700 of the LaboVtode, I shaA.Krrthwh comply with those provisions.
WARNING: FAILURE TO SECURE WO ERS' OMPENSATION COVERAGE ISIUNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL'94NALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
21 Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above informatio is correct. I agree to comply with all
city and county ordinances and state laws relating to bu' ng con tion, d hereby authorize representatives
of this county to enter upon the above-mentioned pro rty for in ecti n p oses.
Application Number
05-00000007
r Permit .
. .
BUILDING PERMIT.
Additional desc..
Permit. Fee.
954.50
Plan. Check Fee'.
620.43
Issue _Date. . .
. ..
Valuation . . .
189075
Expiration Date
12/13/05
Qty, Unit
Charge
Per
Extension
BASE
FEE
639.50
90.00
3.5000
THOU -BLDG
100,001'_500,000.
315.00
--------------------
------
-----------
---------------------------
------------
Permit .
. .
ELECT - ADD/ALT/REM
Additional desc
.
Permit Fee . .
. .
133.98
Plan Check Fee
33.50
Issue Date .
. .
Valuation
0
Expiration Date
12/13/05
Qty Unit
Charge
Per
l
Extension
BASE
FEE
15.00
3165.00
.0350
ELEC
NEW RES - 1 OR 2 FAMILY
110.78
410.00
-------------- ---------------------------------------------------------
:0200
ELEC
GARAGE OR NON-RESIDENTIAL
8.20
Permit .
. .
GRADING PERMIT
Additional desc
.. .
Permit Fee
15.00
Plan Check Fee
.00
Issue Date
Valuation
0
Expiration Date
12/13/05
Qty Unit
Charge
Per
Extension
----.-_------------------
----------------------------------------------------
BASE
FEE
15.00
Permit
. .
MECHANICAL
Additional desc
.
Permit Fee
83.50
Plan Check Fee
20.88
Issue Date
Valuation
0
Expiration Date
12/13/05
" Qty Unit
Charge
Per
Extension
BASE
FEE
15.00
2.00
9.0000
EA MECH
FURNACE <=100K
18.00
2.00
9.0000
EA MECH
B/C.<=3HP/100K BTU
18.00
4.00
6.5000
EA MECH
VENT FAN
26.00
1.00
6.50.00
EA MECH
EXHAUST HOOD
6,.50
Permit . . . .
. .
PLUMBING
J
LQYERMIT - '-
Application Number . . . . . 05-00000007
Permit . . . PLUMBING
Additional desc .
Permit Fee . . . 99.00 Plan Check
Fee
24.75
Issue Date Valuation
0
Expiration Date 12/13/05
Qty Unit Charge Per.
Extension
BASE FEE
15.00
10.00 6.0000 EA PLB FIXTURE
60.00
2.00 7.5000 EA PLB WATER HEATER/VENT
15.00
1:00 3.0000 EA PLB WATER INST/ALT/REP
3.00
8:00 .7500 EA PLB GAS PIPE >=5
6.00 .
-------------------------------------------------------------------=--------
Special Notes and Comments
DEMO HOUSE LEAVING GARAGE AND A FEW
WALLS REBUILD 3165 SQ. FT SFD.May 5,
2005 9:17:25 AM jjohnson: existing
houes was 1304 sq. ft. with a garage of
454 sq. ft. -•
-------------------------------------------------- -------------------------
Other Fees . . . . . . . . . ENERGY REVIEW FEE
62.04
STRONG MOTION (SMI)
- RES
18.-90
Fee summary Charged Paid Credited
----------
Due•
-----------------------------------------------
Permit Fee Total 1285.98 .00
.00
1285.98
Plan Check Total 699.56 .00
.00
699.56
Other Fee Total 80.94 .00
.00
80.94
Grand Total 2066.48. .00
_
.00
2066.48-
LQPERMIT
City of La Quinta
Bulling a Safety. Division'
Permit Fees
Permit #
P.O. Box 1504, 78-495 Cape Tampico
La
000
Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
X
Project Address S Z"- I �i�V
f Al p kV t t 4-_Y_rl Owner's Name: ItIp. Mei. FQf%, JG v
A.P. Number:
Addtrss 1-7 7115 ftvF. V t L file v
LeDescription:
City, ST. Zip: L+ C•?vin/ C.1Contrictor
X
O L,/ A/1:-4 13 (i lL / ,;E4 FTelephone:
-K
:Address
jest Description: %/� /t/f f2 �J^� A M>
i�
City, ST, Zip;
X
Telephone:4�_
'
%r
State Lie. M
C Lic.
City w o ,
Arch., Engr., Designer.
. i4ddtrss:
W 06 p NNCry 200
•
t .�" ��6 t 2a � tL� � 6''na
City. ST, Zip:-
• ;• _'' Construction Type: f Iv Occupancy: ,_ —3
State Lic #:
(circle one):. New Add'n Alta Repair Dam
1C
Name of Contact Person:' �Sv �Tff
S9 Ft • 3 /
M Stories:
X
#U nits:
Telephone tY of Contact Person: S6 C/ - C /%Q 7
. Value of Project:.
APPLICANT:
DO NOT WRITE BELOW THIS UNE
•
N
Submittal
Req•d
Rec'd
TRACKING
Plan Sets
PERMIT FEES
Plan Cheek submided i 305 Item '
Amount
'
Strnctunl Gla.
Reviewed. ready for corrections Plan Check Deposit
Truss Gla.
Called Contact Person Plan Cheek Balance
Energy Gla.
Plans Picked up
of o5 Construction
Flood ptain plan '
Plans resubmitted /
• Mechanical
Grading pian
2" Review, rady.fo come ' Lssne ` . 'C610_5 Electrical
Snbcoatactor List
Called Contact Person
.
�Q Plumbing
•
Grant Deed •
Plans picked up
.111.1.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
''' Review. ready for eorrectio �ssne Dev oper Impact Fee
Plaaaiog Approval
Called Contact Person' �( A.I.P.P.
Pub. Wks. Appr
ADate
of permit Issue
School Fees
Permit Fees
Tract # Study Area
Type Single Family Residence No. of Units 1
Lot # No. Street S.F.
Unit 1 52945 Avenida Velasco 3165 Unit 6
Unit2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments
Lot # No. Street S.F.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.24 X 3,165 S.F. or $7,089.60 have been paid for the property listed above'and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By O/C -Wells Fargo Bank, James Franco Check No. 0050306502
Name on the check Telephone 771-4897
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by Patricia Barbuzza
Signature
Funding Residential tt
- t j y=�
Payment Recdx, $0.00 i C—
.
$7, 089.60 y � verlld6der u
d�?Gnd�tl'I�
NOTICE: Pursuant to Government Code Section M20(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, Whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy -Accounting
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
BERMUDA DUNES
Date
7/12/05
La Quinta, CA 92253
RANCHO MIRAGE
INDIAN WELLS
No.
27417
(760) 771-8515
`a' PALMQUINT �y
U',>R INDIO
y^
Owner
James Franco
APN #
773-325-028-13
Address
52-945 Avenida Velasco
Jurisdiction
La Quinta
City
La Quinta Zip 92253
Permit #
Tract # Study Area
Type Single Family Residence No. of Units 1
Lot # No. Street S.F.
Unit 1 52945 Avenida Velasco 3165 Unit 6
Unit2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments
Lot # No. Street S.F.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.24 X 3,165 S.F. or $7,089.60 have been paid for the property listed above'and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By O/C -Wells Fargo Bank, James Franco Check No. 0050306502
Name on the check Telephone 771-4897
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by Patricia Barbuzza
Signature
Funding Residential tt
- t j y=�
Payment Recdx, $0.00 i C—
.
$7, 089.60 y � verlld6der u
d�?Gnd�tl'I�
NOTICE: Pursuant to Government Code Section M20(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, Whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy -Accounting
TITLE 24 REPORT'
Title 24 Report for:
Mr. & Mrs. Franco
52-945 Avenida Velasco
La Quinta, CA 92253
Project Designer:
Stephen R. Nieto
78-120 Calle Estado Ste. 206
La Quinta, CA 92253
760-564-4707
Report Prepared By:
Stephen R. Nieto ,
South West Concepts
78120 Calle Estado, Suite 206
La Quinta, CA 92253'
(760) 564-4707
s da Job Number:,
Y �/ O
Norl0 N o� 3165
G3AOHddV
'ld3a M3JVS V JNimins Date:
V1N I no vi jO Am
6/10/2005
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 897-6400.
EnergyPro 3.1 By EnergySoft Job Number: 3165 User Number: 5970
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Checklist 6
Form C -2R Computer Method Summary 8
HVAC System Heating and Cooling Loads Summary 12
Room Load Summary 14
EnergyPro 3.1 By EnergySoft Job Number: 3165 User Number: 5970
Certificate of Compliance: Residential . (Part 1 of 2) CF -1 R
Mr. & Mrs. Franco- 6/10/2005
Project Title Date
52-945 Avenida Velasco La Quinta
Project Address Building Permit #
South West Concepts (760) 564-4707 Plan Check I Date
Documentation Author Telephone
Computer Performance 15 Field Check I Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 3,135 ft2 Average Ceiling Height: 9.2 ft
Total Conditioned Slab Area: 3,135 ft2
Building Type:
(check one or more)
X❑ Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (East) 90 deg Floor Construction Type: ® Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 1 ❑ Raised Floor
BUILDING SHELL INSULATION
Orientation
Area
Fenestration
Exterior
Const.
Component
Frame
Assembly
Location/Comments
Type
Type
U -Value
(attic, garage, typical, etc.)
R-38 Roof (R.38.2xl4.16)
Wood
0.028
Exterior Roof
R-19 Wall 0.19.2x6.16)
Wood
0.065
Exterior Wall
Solid Wood Door
Wood
0.387
Exterior Door
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
FFNF-ATRATION Shading Devices
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes / No
Yes / No
Left
(South)
40.0
0.72
0.60
Bug Screen
x❑
❑
❑ x❑
Left
(South)
40.0
0.85
0.59
Roll -down Blind or Slats
x❑
❑
❑ x❑
Left
(South)
53.3
0.72
0.60
Bug Screen
❑
a
❑ o
Left
(South)
53.2
0.87
0.59
Bug Screen
❑
x❑
❑ x❑
Skylight
6.7
0.80
0.69
None
❑
x❑
❑ X❑
Front
(East)
25.0
0.57
0.55
Bug Screen
X❑
❑
❑ X❑
Rear
(West)
20.8
0.72
0.60
Bug Screen
X❑
❑
❑ X❑
Rear
(West)
30.0
0.87
0.59
Bug Screen
X❑
❑
❑ X❑
Right
(North)
70.0
0.87
0.59
Bug Screen
X❑
❑
❑ x❑
El
El
❑❑
❑
❑
❑ ❑
El
El
El
Run Initiation Time: 06/1010514:55:59 Run Code: 1118440559
Ener
Pro 3.1 By Ener
Soft User Number: 5970
Job Number: 3165
Pa e:3 of 15
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
Mr. & Mrs. Franco 6/10/2005
Project Title Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace; heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments
rPntral Furnas_ _ 92%AFUE nucts in Attic 4.2 'Setback Reg HVAC
Central Eurnace 92% AFUE f)ucts in Attic.4.2 S -tba .k RPc_ HVAC
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments
Split Air Conditioner 12.0 SEER Ducts in Attic 42 Setback RP, HVArl
Sunlit Air Conditioner 19 n� Mints in Attic. 42 Setback RPc HVnr,
WATER HEATING SYSTEMS
Water Heater Water Heater Distribution
System Name Type Type
Rated 1
Tank
Energy Fact! 1
External
# in Input
Cap.
or Recovery Standby
Tank Insul.
Svst. Btu/hr
(qal)
Efficiency Loss (%)
R -Value
A n Smith FSG -50-224 Small Gas_ Recirc/Timer 40.000 50 0.55 n/a 12
A.O.Smith FSG -50-224 Small Gas Recirc/rimer 1 40.000 50 0.55 n/a 12
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency_
c1=nenor[C
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: Ste hen"R. Nieto '
Title/Firm: St en R. Nieto " Title/Firm: Soul est Concepts
Address: /8-& Calle Estado Ste. 206 Address: 20 aIle Estado Suite 206
A nooG' a 04nta. CA 92253
Telephon
Lic. #: y sz 3f,/3 7
C 0,s //"`/�-f
r
(signa (date) i ature) (date)
Enfo cement Agency
Name:
Title/Firm:
Address:
Telephone:
(signature/stamp) (date)
Run Initiation Time* 06110105 14*55159 Run Codee 11118440559
EnergyPro 3.1 By EnergySoft User Number 5970 Job Number: 3165 PageA of 15
Certificate of Compliance: Residential (Addendum) CF -1 R
Mr. & Mrs. Franco 6/10/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
uaseu on my auequacy or ine special jusuncatuon ana aocumentation suomittea. Plan I Field
The DHW System "A.O.Smith FSG -50-224" Energy Factor = 0.550. An EF below 0.58 requires an R-12 External Blanket.
The DHW System "A.O.Smith FSG -50-224" Energy Factor = 0.550. An EF below 0.58 requires an R-12 External Blanket.
The HVAC System 'Res HVAC' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
The HVAC System "Res HVAC' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field
The HVAC System "Res HVAC' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System 'Res HVAC' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "Res HVAC' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System 'Res HVAC' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
Run Initiation Time: 06/10/05 14:55:59 Run Code: 1118440559
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 3165 Page:5 of 15
Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
❑X 1150(a): Minimum R-19 ceiling insulation.
§ 150(b): Loose fill insulation manufacturer's labeled R -Value.
§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
not apply to exterior mass walls).
[]'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
E] §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§ 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
❑X
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
a§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
a§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
FX § 1500): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 3165 Page:6 of 15
Mandatory. Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or Initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
FV "§150(m): Ducts and Fans_
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
❑ § 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
X❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
❑ §118 (f): Cool Roof material meet specified criteria
Lighting Measures
® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or gieater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
3,1 By EnergySoft User Number: 5970 Job Number: 3165 Page:7 Of 15
Computer Method Summary (Part 1 of 3) C -2R
Mr_ R Mrs Franco
6/10/2005
Project Title
Date
52-945 Avenida Velasrn
I aQttinta
Project Address
Building Permit #
South West Conrents
(760) 564-4707
Documentation Author
Telephone
Plan Check/Date
COQ uter Perfnrmance
15
Field Check/Date
Compliance Method (Package or Computer)
Climate Zone
Source Energy Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
2.68
2.96
-0.28
Space Cooling
32.09
27.71
4.38
Domestic Hot Water
9.09
13.02
-3.93
Totals
43.85
43.68
0.17
Total Conditioned Floor Area: 3,135 ft2
Building Type: Single Fam Detached
Building Front Orientation: (East) 90 deg
Number of Dwelling Units: 1.00
Number of Stories: 1
BUILDING ZONE INFORMATION
Zone Name Floor Area Volume
OPAQUE SURFACES Act.
Type Area U -Fac. Azm. Tilt
Rnnf 1,316 0.028 _0 0
wall_ 315 0 065 180 90
Roof 1 812 0 028 92
Wall 135 0.065 go go
nnnr 2 0.387 90 90
Wall 320 0 065 270 AQ
Wall 580 0.065 0 A0
Solar
Gains
Floor Construction Type: ❑ Raised Floor ❑X Slab Floor
Total Fenestration Area: 10.8%
Total Conditioned Volume: 28,873 ft 3
Total Conditioned Slab Area: 3,135 ft 2
# of
Units
Zone Type
r:nnditinnPd
CnnditinnPd
Thermostat Vent
Type Hgt. Area
SPthark _2 n/a
SPthark -2 n/a
Location / Comments
1st Flnnr 7nne 2
10 Floor Zone 2
1 qt Flnnr 7nne 1
1st Flnnr 7nne 1
1st Flnnr 7nne 1
1St Flnnr 7nnp 1
1st Flnnr 7nne 1
I EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 3165 Paae:B of 15 1
Computer Method Summary (Part 2 of 3) C -2R
Mr. & Mrs. Franco 6/10/2005
Project Title Date
FENESTRATION SURFACES
# Type
Area
U-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
Location/
Comments
1
Window Left
(, out
9()O
0 720
0 60
180
An Double Metal Low e
1 st Floor Zone 2
2
Window Left
.(South)
40.0
0.850
0.59
180
90 Double Metal Low e
1 st Floor Zone 2
3
Window Left
(South)
20.0
0.720
0.60
180
,
90 Double Metal Low a
1st Floor Zone 2
4
Window Left
(South)
26.6
0.720
0.60
180
90 Double Metal Low a
1st Floor Zone 2
5
Window Left
(South)
53.2
0.870
0.59
180
90 Double Metal Low a
1st Floor Zone 2
6
Window Left
(South)
26.6
0.720
0.60
180
90 Double Metal Low a
1st Floor Zone 2
L
Skylight Right
(North)
3.4
0.800
0.69
0
22 Mtl Thermal Brk Clear Default
1 st Floor Zone 1
8
Skylight Right
(North)
3.4
0.800
0.69
0
22 Mtl Thermal Brk Clear Default
1 st Floor Zone 1
6
Window Front
(East)
25.0
0.570
0.55
90
90 Double NonMtl Tinted Default
1 st Floor Zone 1
10
Window Rear
(West)
2.0
0.720
0.60
270
90 Double Metal Low a
1st Floor Zone 1
_U
Window Rear
(West)
18.8
0.720
0.60
270
90 Double Metal Low e
1 st Floor Zone 1
12
Window Rear
(West)
30.0
0.870
0.59
270
90 Double Metal Low e
1 st Floor Zone 1
_1a
Window Right
(North)
20.0
0.870
0.59
_0
90 Double Metal Low e
1 st Floor Zone 1
14
Window Right
(North)
20.0
0.870
0.59
0
90 Double Metal Low e
1 st Floor Zone 1
15
Window Right
(North)
15.0
0.870
0.59
0
90 Double Metal Lowe
1 st Floor Zone 1
16
Window Right
(North)
15.0
0.870
0.59
0
90 Double Metal Low e
1 st Floor Zone 1
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin
Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len. Hgt.
LExt. RExt. Dist. Len.
Hgt. Dist. Len. Hgt.
1
Bug Screen
0.76
6.7
3.0
2.0
0.1
2.0 2.0
2
Roll -down Blind or Slats
0.13
6.7
6.0
2.0
0.1
2.0 2.0
3
Bug Screen
0.76
6.7
3.0
2.0
0.1
2.0 2.0
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
None
1.00
8
None
1.00
9
Bug Screen
0.76
5.0
5.0
2.0
0.1
2.0 2.0
10
Bug Screen
0.76
1.0
2.0
2.0
0.1
2.0 2.0
11
Bug Screen
0.76
4.0
4.7
2.0
0.1
2.0 2.0
12
Bug Screen
0.76
5.0
6.0
2.0
0.1
2.0 2.0
13
Bug Screen
0.76
5.0
4.0
2.0
0.1
2.0 2.0
14
Bug Screen
0.76
5.0
4.0
2.0
0.1
2.0 2.0
15
Bug Screen
0.76
5.0
3.0
2.0
0.1
2.0 2.0
16
Bug Screen
0.76
5.0
3.0
2.0
0.1
2.0 2.0
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 3165 Paae:9 of 15 1
Computer Method Summary
Minimum
(Part 3.of 3) C -2R
Mr. & Mrs. Franco
6/10/2005
Project Title
Efficiency
Date
THERMAL MASS FOR HIGH MASS DESIGN
Location /
Area Thick. Heat
etc.)
Inside Location
Type (sf) (in.) Cap.
Cond. Form 3 Reference
R -Val. Comments
Frame Wall, Stucco 135 —QM --21
047 R-19 Wall (W.19 2x6 16)
2 1 qt Floor 7nnp 1 / Exterior Macs
PERIMETER LOSSES
Central Furnace
- F2 Insulation
Ducts in Attic
Type Length Factor R -Val.
Depth 'Location /Comments
Slab Perimeter 252 0.76 0.0
0 1 st Floor Zone 1
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Type (furnace, heat
Efficiency
and Location
Duct Thermostat
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic,
etc.)
R=Value Type
Comments
Central Furnace
92%AFUE
Ducts in Attic
4.2 Setback
Res HVAC
Central Furnace
92%AFUE
Ducts in Attic
4.2 Setback
Res HVAC
Pipe
Insul.
Hydronic Piping Pipe
System Name: Length
Diameter Thick.
Cooling Equipment
Minimum
Duct
Type (air conditioner,
Efficiency
Location
Duct Thermostat
Location /
heat pump, evap. cooling)
(SEER)
(attic, etc)
R -Value Type
Comments
Split Air Conditioner
12.0 SEER
Ducts in Attic
4.2 Setback
Res HVAC
Split Air Conditioner
12.0 SEER
Ducts in Attic
4.2 Setback
Res HVAC
WATER HEATING,SYSTEMS
Ratedl Tank
Energy Fact!
1 Tank Insul.
Water Heater
Water Heater Distribution
# in Input Cap.
or Recovery
Standby R -Value
System Name
Type
Type
Syst. (Btu/hr) (gal)
Efficiency
Loss (%) Ext.
A.O.Smith FSG -50-224
Small Gas
Recirc/Timer
1 40,000 50
0.55
n/a 12
A O.Smith FSG -50-224
Small Gas
Recirc/fimer
1 40.000 50
0.55
n/a 12
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
Comauter Method Summary (Addendum) _ C -2R
Mr. & Mrs. Franco 6/10/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to2 be used with the performance approach. The local
. 9— .....6 ae•e...,i.,o. rho „tonliary of the hm ifiratien_ and may reiect a buildina or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. Plan Field
The DHW System "A.O.Smith FSG -50-224" Energy Factor = 0.550. An EF below 0.58 requires an R-12 External Blanket.
The DHW System "A.O.Smith FSG -50-224" Energy Factor = 0.550. An EF below 0.58 requires an R-12 External Blanket.
The HVAC System 'Res HVAC' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
The HVAC System 'Res HVAC" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field
The HVAC System 'Res HVAC" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System 'Res HVAC" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "Res HVAC" includes. Refrigerant Charge and Airflow Credit (ora TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System 'Res HVAC" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a. CF -6R Form.
Run Initiation Time: 06/10/05 14:55:59 Run Code: 1118440559 1
EnergyPro 3.1 By Energysoft User Number: 5970 Job Number: 3165 Page: 11 of 15
iVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Mr. & Mrs. Franco 6/10/2005
SYSTEM NAME FLOOR AREA
Res HVAC 1,316
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
I COIL HTG. PEAK
CFM
I Sensible
Latent
CFM
I Sensible
15,756 612 1 9 941
BDP CO. 563AN060-A 43,707 5,056 112,000
Total Adjusted System Output 43,707 5,o5s 112,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
26.0 of 69.8 of 69.8 OF ■ 121.0 of
%� J %� /' %�
Outside Air
0 cfm
Supply Fan Heating Coil
2055 cfm
69.8 of
h Return Air Ducts ',i
Supply Air Ducts
120.8 of
ROOMS
70.0 of
(COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I
15.0/73.5°F 78.3/62.5°F 78.3/62.5OF . 58.3/55.1OF
Outside Air
0 cfm
78.3/62.5 OF
Supply Fan Cooling Coil .
2055 cfm
h Return Air Ducts "I
Supply Air Ducts
58.7 / 55.2 of
41.6% R.H. ROOMS
78.0 / 62.4 of
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 3165 Page:12 of 15
N
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Mr. & Mrs. Franco 6/10/2005
SYSTEM NAME FLOOR AREA
Res HVAC 1,819
Number of Systems
1
Heating System
Output per System
112,000
Total Output (Btuh)
112,000
Output (Btuh/sqft)
61.6
Cooling System
Output per System
58,000
Total Output (Btuh)
58,000
Total Output (Tons)
4.8
Total Output (Btuh/sqft)
31.9
Total Output (sgft/Ton)
376.3
Air System
CFM per System
2,055
Airflow (cfm)
2,055
Airflow (cfm/sgft)
1.13
Airflow (cfm/Ton)
425.2
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
I COIL HTG. PEAK
CFM
Sensiblel
Latent
I CFM
Sensible
1,103
26,991
-40
758
28,230
0
1,350
1,41
0
0
0
0
0
0
0
0
0
1,3501
1,411
29,6901 -40 =052
BDP CO. 563AN060-A 44,688 3,905 112,000
Total Adjusted System Output 44,688 3,905 112,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm 1 Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heatin Peak
26.0 OF 69.4 OF 69.4 OF 105.0 OF
OSupply Air Ducts
Outside Air
0 cfm
Supply Fan Heating Coil 104.4 OF
2055 cfm ROOMS
69.4 OF 70.0 °F
�% Return Air Ducts 4
T
15.0/73.5°F 78.6/62.3°F 78.6/62.3°F . 55.0/53.6°F
Outside Air
0 cfm
78.6/62.3 °F
Supply Fan Cooling Coil
2055 cfm
Return Air Ducts
Supply Air Ducts
55.6 / 53.8 of
40.6% R.H. ROOMS
78.0 / 62.1 OF
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 3165 Pane: 13 of 15
ROOM LOAD SUMMARY
PROJECT NAME
DATE
Mr. & Mrs. Franco
6/10/2005
SYSTEM NAME
FLOOR AREA
Res HVAC
1,316
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
1st Floor Zone 2
1st Floor Zone
1
696
14,324
612
696
14,324
612
167
9,038
PAGE TOTAL 1 0961-
96 14,324 61211 167 9,038
TOTAL 1 696 14,324 612 167 9,038
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 3165 Page:14 of 15
R� LOAD SUMMARY E
PROJECT NAME
Mr. & Mrs. Franco
DATE �
6/10/2005
SYSTEM NAME
Res HVAC
FLOOR AREA
1,819
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
ZONE NAME
ROOM NAME Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE.
1st Floor Zone 1
1st Floor
1
1,103
26,991
-401
1,103
26,991
-401
758
28,230
PAGE TOTAL 1 1,103 26,991 401
- TOTAL 1 1,103 26,991 401
758
28,230
758
28,230
EnergyPro 3.1 By EnergySoft User Number: 5970 Job Number: 3165 Page: 15 of 15