Loading...
09-0006 (RER)P.O.. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 09-00000006 53251 AVENIDA VELASCO - 774-084-024-3 -000000- REMODEL RESIDENTIAL. COVE RESIDENTIAL 150000 Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: ` Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter: improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects.the applicant to a civil penalty of not,more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( /)I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. , B.&P.C. for this reason Date: PC;—�X;3 109( Owner: CONSTRUCTION LENDING AdENCY 1 hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued.(Sec. 3097, Civ. C.). Lender's Name: Lender's Address: 14 L14_ LQPERMIT Owner: BOB HULL 53251•AVENIDA LA QUINTA, CA Contractor: Owner- VELASCO 92253 APR 13 2009. CITY OF LA QUI A VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/10/09 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: - _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I haveandwill maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number 1 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 34700 of the Labor�Lntf, ith comply with those provisions. bate I pplicant: WARNING: FAILURE TO SECURE -WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to.the . conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property r inspection poseAs.w,.., date : 1 7 1d � nature (Applicant or Agent): V Application Number . . . . . .09-00000006 ------ Structure Information REMODEL/1,340SF ADDITION/VB/RES-3/CL-A ----- other struct info CODE EDITION 2007CBC ---------------------------------------------------------------------------- # BEDROOMS 3.00 Permit .' BUILDING PERMIT Additional desc . Permit Fee •. . . . 814.50 Plan Check Fee 529.43 Issue Date . . . . Valuation . . . . 150000 Expiration Date 10/07/09 Qty Unit Charge Per Extension BASE FEE 639.50 50.00 3.5000 --------------------------_-------------------------------------------------- THOU BLDG 100,001-500,000 175.00 Permit . ... ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . 172.60 Plan Check Fee 43.15 Issue Date . . . . Valuation . . . . 0 '.Expiration Date 10/07/09 Qty Unit Charge Per Extension BASE FEE 15.00 3181.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 111.34 438.00 .0200 ELEC GARAGE OR NON:RESIDENTIAL 8.76 1.00 37.5000 --------------------=-------------------------------------------------=----- EA ELEC SVC <=600V/>200A/<=1OOOA 37.50 Permit . . . MECHANICAL Additional desc . Permit Fee 104.50 Plan Check Fee 26.13 Issue Date Valuation . . . . 0 Expiration Date 10/07/09 Qty Unit Charge Per Extension BASE FEE 15.00 1-.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 2.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 33.00 2.00 6.5000 EA MECH AH <=10K CFM 13.00 5.00 6.5000 EA MECH VENT FAN 32.50 1.00 6.5000 ------------------------------------------- EA MECH EXHAUST HOOD --------------------------------- 6.50 Permit, PLUMBING Additional desc . Permit Fee 170.25 Plan Check Fee .. 42..56 LQPERN11T Application Number . . . . . 09-00000006 Permit . . . . . PLUMBING Issue Date . . . . Valuation 0 Expiration Date 10/07/09 Qty Unit Charge Per Extension _ BASE FEE 15.00 17.00 6.0000 EA PLB FIXTURE 102.00 2.00 6.0000 EA PLB ROOF DRAIN 12.00 1.00- 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00• 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 9.00 .7500 EA PLB GAS PIPE >=5 6.75 1.00 15.0000 EA PLB GAS METER 15.00 Special Notes and Comments REMODEL TO EXISITING 1,854SF RESIDENCE WITH 1;340SF.ADDITION/VB/RES-3/CLASS A -FR [ENGINEERED] THIS PERMIT DOES NOT INCLUDE NEW CONNECTION TO.SEWER(EXISTING ONLY)., BLOCK WALLS OR DRIVEWAY APPROACH. 2007 CALIFORNIA BUILDING CODES. April 10, 2009 12:46:37 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . BLDG STDS ADMIN (SB1473) 6.00 ENERGY REVIEW FEE 52.94 STRONG MOTION (SMI) - RES 15.00 Fee summary Charged Paid Credited Due Permit Fee Total 1261.85 .00 ..00 1261.85 Plan Check Total 641.27 .00 .00 641.27 Other Fee Total 73.94 .00 .00 73.94 Grand Total 1977.06 .00 .00 1977.06 LQPERMIT ,�..� .•.` � 67` t r « ^i iy6, g t �b� x. `K! .mac w. � ' ��.: ` N'ati•}� � yf t � � .•! �' � 1 i s %fR r y `^�.� � . `-moi. R' .Js'! �.+ v�yj. y� � rYlewe«a..W �, � ti ] ri {.�1. .` +�Y• �'1_.•�t y ..!},,; t .M-,. VaC ...'•V; ! `.�' "}:-moi+ '� 4. d� 1c�••J•f^Yh' t'yT�Q'?�,��µ ..`• � s �`• tY!'� �. ., � . � .w. - �[ it -+VHF �_�i `+Oc-.w. f-�..�1�-y�, �w {- --- /. ��A�r✓,': �-'-Y.fin•�iF+•.,}a. � -.. \+iM+.+-,i'.., t, e --A ♦ ...... . .. (C.. ._. y� "� }i. -,may. ('+2 '.� Z�r L S� � Lt�` Y. i '1 j '�'^rTt .f".,4 + # 1J � >'r �= .�. d+. �Y - .y. �-�;a '�'� L .•t f" ?��j'��i ,u, .�.ya �(! y -1't '�'Y '!�� .r•Z`� ��" . - �r�•.`%;y�e„'! ,.� 't - - err � �-�'�a.�`�` '�L - �� ,� -' �` fir:. �F�._ .- i.. . r `k .. +. •ail. r.�• _ �L.� ?*' ,...K�� it •; k . .r 7YS.•+R �� � � A� ..� F � f •' ''k. 4 —_ ©. w Yb,M —� ' ' W� - �irJ�ir vs�Y _�s • f , r R ` Fye ------- --—]q (.� ____.— -- _. _--�—___.____–•----- - ._' ,. r •;Y ;�� )_f , � � try_• 1 ' ! f.r • �_�--_ ____ ___ �,. _� a � - —. yJ'••: <7f. �Cw''��'j'` its �-p . Apr 13 2009 11:42 HULL -FARMS Apr 13 09 12:21p Sue Wiley 760 922 0357 5419975163 ACOR& CERTIFICATE OF LIABILITYINSURANCE OATE1 /2009 Y) 4/13/2009 PRODUCER (541) 997-5010 FAX: (541) 997-5163 THIS CERTIFICATE JS ISSUED AS A MATTER OF INFORMATION Western Sierra Insurance Services, LLC ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE \ HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR License #0EE75976 ALTER THE COVERAGE AFFORDED BY THE POLICIES eELOW 4715 Heceta Beach Road Florence OR 93711 INSURERS AFFC)RDING COVERAGE MAIC p INSURED ' N3LIRERA:StaY Insurance com an' ' Hull Farms Inc. NSURER B: TraveierS Ins Com an 29501 Neighbors Boulevard NSURE.RC; ER D• NSUR- ' Blythe CA 92225 SURER E: FRAGFS THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE IN5URE NAMED ABOVE FOR THE POLICY PERIOD INDICATED, I;OTWITHSTA.VDING ANY REQUIREMENT. TERM OR CONDMON CF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH T1 -1S -UERTIFICATE MAY 3E ISSUED OR .MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES CESCRIBED HERON IS SUBJE T TO ALL TME TERMS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. G SSH MAY - D V 1 I MSR IMFAgb'L� P LILY EFFECTIVE POLICY EXPIRATION I.MTYPE OF INSURANCE POLCY IAJNBER 0 TE IIAIWOblYY1 GATE &1MJppryY LItl11TS G.EN ERAL LIABILITY • EACH Dcx-+,RREN� • s 100000C %C CONMERC'ALGENERALLIAEILITY 700 -2985L245 -TIL -08 06/10/08 06/10/09 DFJIMG E TQ REE TQ RENTED P rt x e SOOOC J3 - CLAWS MADE a OCCUR MEO EXP (Ami a -a e,¢an S 5000 ' -RS Nq V I UP S 1000000 GENERALGGREGq S 2000000 GEN'L AGGREGATE LIlL11T APPLI ES PER: U -C JDP S 2000000 OLPRO- IC OC AUTTNLOBILE UAMUTY AIYAUTO COMBINED SINGLE LIME' (Eaae:Rdenq 6 ALL OVN4iEDAL'TOS BODILY INJURY ECHEOULEDAUTOS (PLY T.ersonl 9 H REO AUTOS NON•OV*EDAt1TOS - ' ' BODILY INJURY S (Peraoelno.t) PROPERTY DAMAGE $ (Pel a=loenl) GARAGE UAISILITV . ANY AUTO • AUTO ONLY • EA.nCCJO °NY E OTHER THAN Aq S AUTO Or.LY: AGG 5 EXCE56JUrMRELLA LIABILITY OCCUR FICLAMS MADE OEDUCTI BLE RETE TION A-ORKERS COMPENSATION AND EMPLDYERS' LIABILITY ANY PROPRIETORIPARTVEFUEXECUTNE OFFICER:MENBEREXCLUDED7 WC D452B61 If yas, oesaDr ur:er P C L PROVISION OTN ER 142/2009 11/1/2010 DESOR TION OF OPERA TIONSILOICATIC NS.NEN ICLESJEXCLUS IONS ADDED BY.ENDORSEMENVs As SOspacts: 53-251 Avenida Velasco, I -A Quinta,-CA 92253 CERT ACORD 25 (2001108) INS026 ONS 1,000,000 1,000,000 1,000 D00 0 ANY OF THE ABOVE DESCRIBED POLICIES 09 CANCELLED BEFORE THE TION DATE THEREOF, YHE ISSUIND INSURER WILL ENDEAVOR TO MAIL DAYS WRaMEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT E TO 00 SO SHALL IIAPOSE NO O SUDATION O R LIABILITY OF ANY VJNO UPON THE iR, IT$ AGENTS OR REPRESENTATIVES. IFED REPRESENTATIVE T Hansen 9) ACORD CORPORATION 1988 Page 1 012 Bin # V _,City -of 4La Quinta 1 � Building,u Safety Division P.O. Box 1504, 78-495 Calle Tampico La'Quinta, CA 92253 - (760) 777-7012 Building Permit Application- and Tracking Sheet Permit # RO* J ® Project Address: rj�Ja�j (?� -fA_*�%\ &per 0 SCA Owner's Name: �� 1 A. P. Numbei: Address: 53x5\ �t.C�4 vR�p•5(s� Legal Description: Contractor: City, ST, Zip: - c�1'a-53 Telephone: 114 0\$`' Address: Project Description: City, ST, Zip: Telephone: - I'. RtibW'OState rcity Lic. # : Lic. #: r( Arch., Engr., Designer:.CA1 _\iLS CIO 0•-(16- e1 Address: 1y City, ST, Zip: Qc.A,--,6,0 ' Telephone: 11o11Z. State Lic. #: ' yam" ` Name of Contact Per 1 0' �� Construction Type: Occupancy: , Project type (circle one): New Add'n Alter Repair Demo q. Ft.: \'��Q .. # Stories:. # Units: Telephone # of Con ct Person:,.:) AD -105,S 11 S Esti ated Value of Project: 5Qp013 ?= OT WRITE BELOW THIS LINE # Submittal Req'd Ree'd TRACKING PERMIT FEES Plan Sets 3 - Plan Check submitted IC�. qq �I �� La mi.�, i IV in Amount Structural Cales. II �. I z Reviewed, ready for corrections i;Plan Check Deposit Truss Calcs. Called Contact Person .NUU Z�-Plan Check Balance Energy Calcs.. Plans bicked up JSy Construction Flood plain plan Plans resubmitted o�� Mechanical Grading plan 2'dReview, ready 10 r(orre ons/issue Electrical Subcontactor List Called Contact P n Plumbing Grant Deed Plans picked upt)-Z6 Ii.O.A. Approval . GradingFos, IN HOUSE:- vwww- Re w, ready for correctio ss Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue' School Fees W4�. Total Permit Fees 4 2rm- Ns �C2�,co Ate)• 3-i� r � CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road - ¢ BERMUDA DUNES 0 Date 4/13/09 La Quinta, CA 92253 N NDIAN WELLSE No. 30362 (760) 771-8515 �� PALM DESERT LA QUINTA �y • 1PINDIO y� . o Owner Bob Hull APN # Address 53251 Avenida Velasco Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 53251 Avenida Velasco 1340 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for Irving, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has-been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to , Education Code Section 17620 and Government Code 65995 Et Seq. 4 in the amount of $2.97 X 1,340 S.F. or $3,979.80 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees.Paid By CC/Provident Bank Doug Bogren Check No. 210033 Name on the check Telephone 702-5175 Funding -Residential yt"4�� J fwJ By Dr. Sharon P. McGehee ��� `'�•" -%f, Superintendent r. z",� f . W`� 3 Fee collected /exempted by har6 cGilvrey Payment Recd y�Q.00 I 'L �•j \ $3979.80 !6ve;r1Under t;-+� r \ Signature �` ; 1 NOTICE: Pursuant to Government Code Section 66020(d)(1), will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original.- Building Department Applicant . Copy - Applicant/Receipt Copy - Accounting • 5 P.O. Box 1504 78-495 CALLE TAMPICO LA_ QUINTA, CALIFORNIA 92253 To: Greg Butler, Building & Safety Manager From: Les Johnson, Director -PDD Permit #: 09-06 BUILDING & SAFETY DEPARTMENT (760)',777-7012 'FAX (760) 777-7011 1 To PD: 03-03-09, Due Date: 03-12-09 Status: 1St REVIEW Building; Plans Approval (This is an approval to issue a Building Permit) The Planning Department has reviewed the Building Plans for the following project: Description: HOUSE REMODEL AND ADDITION Address or General Location: 53-251 AVENIDA VELASCO Applicant Contapt: DOUG BOREN 760-702-5175 The Planning Development Department finds that: ❑ ...these Building Plans do not require Planning Department approval. these Building Plans are approved by the Planning Department. 11111kk ... ❑ ...these B ilding Plans require corrections. Please forward a copy of the atta h�retutn d corrections to the applicant. When the corrections are made lea them to the Planning Department for review. , N7rector-PD ate TITLE 24. REPORT Title 24 Report for: Mr. Bob Hull 53251 Avenida Velasco La Quinta, Ca 92253 Project Designer: . . l Report Prepared By: Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, CA 92247 (760) 485-8927 CITY OF LA QUINTA ` Job Number: BUILDING & SAFETY DEPT. Ig010409 APPROVED, CONSTRUCTION DATE Date: 91UAR C 2009 3/5/2009 ey The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program as approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: Ig010409 User Number: 5732 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance .3 Form MF -1 R Mandatory Measures Summary 8 Form WS -5R Residential Kitchen Lighting 10 HVAC System Heating, and Cooling Loads Summary 11 a .F s EnergyPro 4.4 by EnergySofl Job Number: Ig010409 User Number: 5732 Certificate Of Compliance: Residential ft2 (Part 1 of 4) CF -1 R Mr Rnh Hull Project Title ft2 Raised Floor Area: 0 3/S/ 009 Date 53991 AyP.niria Velasm I a Quinta ft2 Average Ceiling Height: 10.0 Project Address Number of Dwelling Units: 1.00 Building Permit # Santiago I z-Ocamnn (760) 485-8927 Documen ation Author ' Telephone plan Check/Date FnPr r0 Complira-6ce Method CA CIimatP 7nnc 1. Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.71 2.59 0.12 Space Cooling 69.36 64.42 4.93 Fans 9.81 9.12 0.69 Domestic Hot Water 13.35 10.68 2.67 Pumps 0.00 0.00 0.00 Totals 95.23 86.82 8.41 better than Standard: Building Type: Y Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: Area: 675 ft2 Ratio: 21.2% BUILDING ZONE INFORMATION ❑ Addition ❑ Existing + Add/Alt (NE) 45 deg Propane Avg. U: Avg. SHGC: Zone Name Floor Area HVAC System -ZONF1 ,T6-03 HVAC' System -7nNF 9 1 57R 0.35 Total Conditioned Floor Area: 3,181 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 3,181 ft2 Average Ceiling Height: 10.0 ft Number of Dwelling Units: 1.00 0.26 Number of Stories: 1 # of Thermostat Vent Volume Units Zone Type Type Hgt. Area 1442Z —050_ fonditioned Setback 2 —n/ 17 35R n SO (nnditinnarl SPthark _2 n/a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Roof Wood 1 601 n 095 R-38 _R_0 0 x-16 Wall Wnnd 156 n n6g R-91 R -n n_ 45 A Wall Wnnd 64 n 069 R-91 R -n n 135 A() Wall Wood 956 _0 069 —R_91 R -n n —22Rg0 Wall Wnnd 6n n n6g R_91 R_n n 97n _g0 Wall Wood :357 n n69 R-91 R_n n 31 S _g0 Roof Wood 1 567 _0 029 R-38 _R_0 0 n—t6 Wall Wood 89 n 069 _R 91 X0 0 45 _9D Wall Wnnd 7.30 n n69 R-91 R_n n _ 45_ P nnnr NnnP 94 0 S0()_ NnnP R -n 45 Pf) Wall Wnnd 75 _0 069 —R_21 R_n n 45 PD Wyll M/nnd 39 n 069 R_91 R_n ngn _9 Wall Wnnd 1:;n n n69 R_91 R_n n 1 I 9n Wall Wnnd 37 n n69 R_91 R_n n 1Rn An Wall Wnnd 1An n n69 R-91 R_n n 135 9Q Wall Wnnd 1R5 n n69 R_91 R -o n 135 An Wall Wood 109; n 069 R_91 R_n n 925 _g0 Wall Wood 90 _0 069 —R_21 R_n n _225 —90 Wall Wood 130 X069 _R -91_R=00 —315 _90 Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig010409 Paae:3 of 12 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Mr. Bob Hull 3/5/2009 Project Title Date FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Location/ Comments 1_ Skylight Right n5 nn 49n NERC Q NFRC _n 1_ New 10" SnlatuhP Frosted -p ti view 7nnP 1 2 Skylight Right (N) 0.5 0.420 NFRC 0_40 NFRC 0 16 New 10" Solatube Frosted-OptiView Zone 1 3 Skylight Right (N) 0.5 0.420 NFRC 0_40 NFRC 0 16 New 10" Solatube Frosted-OptiView Zone 1 4 Skylight Right (N) 0.5 0.420 NFRC 0_40 NFRC 0 16 New 10" Solatube Frosted-OptiView Zone 1 5 Window Front _(NE) 36.0 0.370 NFRC0 26 NFRC 45 90 New Jeld-Wen Clad -Wood LowE cas Zone 1 5 Window Left (,S) 4.5 0_370 NERC 0_26 NFRC 135 90 New Jeld-Wen Clad -Wood LowE cas Zone 1 Z _Window Rear (SM 6.0 0_320 NFRC 0_32 NFRC 225 -RO- New Jeld-Wen Clad -Wood LowE fix Zone 1 8 Window Rear (SW) 40.0 0.340 NFRC 0_24 NFRC 225 90 New Jeld-Wen Clad -Wood LowE sqd Zone 1 4 Window Rear _(SM 40.0 0_340 NFRC 02_4 NFRC 225 Qn New .geld -Wen Clad -brood LowF cad Zone 1 JD Window Rear (WJ 30.0 0_320 NFRC 0"32 NFRC 270 qQ New Jeld-Wen Clad -Wood LowE fix Zone 1 " Window Right (i1)pg 15.0 0=320 NFRC -Q-a2 NFRC 315 90 New Jeld-Wen Clad -Wood LowE fix Zone 1 12 Window Right (Na 24.0 0_340 NFRC 0_23 NFRC 315 90 New Jeld-Wen Clad -Wood LowE fr,dr, Zone 1 1g 14 Window Window Right Right (NW; 60037 37o NFRC _0 9 NFRC315 Qf)_ New Jeld-Wen Clad -Wood I owF ca-, (NW) 6.0 0_370 NFRC 0_26 NFRC 315 90 New Jeld-Wen Clad -Wood LowE cas Zone 1 Zone 1 15 Window Right (NE 64.0 0.340 NFRC 0_24 NFRC 315 90 New Jeld-Wen Clad -Wood LowE sgd Zone 1 16 Window Right (No 9.0 0.350 NFRC 0428 NFRC 315 90 New Jeld-Wen Clad -Wood LowE xo Zone 1 17 Window Right (NW) 9.0 0.350 NFRC 0_28 NFRr 315 90 New Jeld-Wen Clad -Wood LowE xo Zone 1 18 Window Right (NW) 64.0 0.340 NFRC 0_24 NFRC 315 90 New Jeld-Wen Clad -Wood LowE sgd Zone 1 J2 Skylight Right (_N) 55 &55 NFRC 0.40. NFRC _0 16_ New Andersen 400 Series Roof Wndow7nne 2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Area Thick. Heat Inside (so (in.) Cap. Cond. R -Val. JA IV Reference Window Overhand Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 None 1.00 3 None 1.00 4 None 1.00 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 076 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 None 1.00 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat Inside (so (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments Concrete, Heavyweight 181 3.50 28 0_98 0 26-A1 Existing Zone 1 / Slab on Grade Concrete, Heavyweight 173 4.00 28 0_98 0 26-A1 New Zone 1 / Slab on Grade Concrete, Heavyweight 1.096 3.50 28 0_98 2 26-A1 Existing Zone 1 / Slab on Grade Concrete, Heavyweight 153 4.00 28 0_98 2 26-A1 New Zone 1 / Slab on Grade Concrete, Heavyweight 922 4.00 28 0_98 0 26-A1 New Zone 2 / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 03/05/09 01.08.59 Run Code: 1236244139 EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig010409 Page:4 of 12 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Mr. Bob Hull 3/5/2009 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGC2 20 Skylight Right _4N)_ 0 SSn NFRC 04 NFRC 21 Window Front (NE) 1.3 0.320 NFRC 0_32 NFRC 22 Window Front (NE) 1.3 0.320 NFRC 0_32 NFRC 23 Window Front (NE) 1.3 0.320 NFRC 0_32 NFRC 24 Window Front (NE) 9.0 0_320 NFRC 0_32 NFRC 25 __Window Front (jam) 12.0 0=370 NFRC -0-M NFRC 2E Window Front (NE) 12.0 0_370 NFRC JIM NFRC 27 Window Front (NE) 36.0 0.370 NFRC 0_26 NFRC M Window Front (E) _ 25.0 0_350 NFRC J128 NFRC 29 Window Left (,S) 25.0 035 NFRC JJa NFRC M Window Left (SE) 25.0 0.320 NFRC 0.32 NFRC 31 Window Left (SE) 64.0 0.340 NFRC 0.24 NFRC -a2 33 Window I eft Window Rear (,E) 15 000 350 NFRC = NEgC. (S 15.0 0.350 NFRC 0.27 NFRC 34 Window Rear (SW) 64.0 0.340 NFRC 0_24 NFRC -a5 Window Rear (SW) 1.3 0.320 NFRC 0.32 NFRC 36 Window Rear (SW) 1.3 0.320 NFRC 0_32 NFRC True Cond. Location/ Azm. Tilt Stat. Glazinq Type Comments Q_ 16 New Andersen 4171n Rerles Rnnf VAindnw7nnc i 45 90 New Jeld-Wen Clad -Wood LowE fix Zone 2 45 90 New Jeld-Wen Clad -Wood LowE fix Zone 2 45 90 New Jeld-Wen Clad -Wood LowE fix Zone 2 45 90 New Jeld-Wen Clad -Wood LowE fix Zone 2 45 90 New Jeld-Wen Clad -Wood LowE cas Zone 2 _45 --qQ New Jeld-Wen Clad -Wood I nwE cas Zone 2 45 90 New Jeld-Wen Clad -Wood LowE cas Zone 2 90 --M New Jeld-Wen Clad -Wood LowF xo Zone 2 180 -2Q New Jeld-Wen Clad -Wood LowE xo Zone 2 135 90 New JeId-Wen Clad -Wood LowE fix Zone 2 135 90 New JeId-Wen Clad -Wood LowE sgd Zone 2 135 _90_ New Jeld-Wen Clad -Wood I nwF sh' 225 90 New JeId-Wen Clad -Wood LowE sh Zone 2 Zone 2 225 90 New JeId-Wen Clad -Wood LowE sgd Zone 2 225 90 New JeId-Wen Clad -Wood LowE fix Zone 2 225 90 New JeId-Wen Clad -Wood LowE fix Zone 2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. `Len. Hgt. 20 None 1.00 21 Bug Screen 0.76 22 Buq Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Buq Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 656 3.50 28 0_98 0 26-A1 Existing Zone 2 / Slab on Grade PERIMETER LOSSES Insulation Type Lenqth R -Val. Location JA IV Reference Condition Location/ Status Comments Run Initiation Time: 03/06/09 01:08:59 Run Code: 236244139 EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig010409 Page:5 of 12 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Mr. Bob Hull Duct Condition Ducts Location Heating Cooling Location R -Value Status 3/5/2009 HVAC System - ZONE 1 Ducted Ducted Attic Project Title No HVAC System - ZONE 2 Ducted Ducted Attic 8.0 New Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location -Type Eff Type Eff Status Type HVAC System -ZONE 1 Central Furnace 80% AFUE Packaged Air Conditioner 14.0 SEER New Setback HVAC System -ZONE 2 Central Furnace 80% AFUE Packaged Air Conditioner 14.0 SEER New Setback .1�IL��1l~�1:711�jiL7► Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC System - ZONE 1 Ducted Ducted Attic 8.0 New No HVAC System - ZONE 2 Ducted Ducted Attic 8.0 New No. Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Takagi T -H1 Instant Gas No Pipe Insulation 1 199,000 0 New 0.92 500 n/a ( Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # ''HP Type In Plenum Outside Buried Insulation REMARKS UUMVLIANUt J I All tlyltN 1 This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business 8 Professions Code) Name: Title/Firm: Address: Telephone: Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) Documentation Author Name: Title/Firm: Santiago Lopez-Ocampo Address: P.O. Box 1018 La Quinta. CA 92247 T e: 760 85-8927 (signature) (date) Certificate Of Compliance: Residential (Part 4 of 4) CF-1R Mr. Bob Hull 3/5/2009 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan Field The Roof "R-38 Roof Attic w/Radiant Barrier' includes a Radiant Barrier. HIGH MASS Design - Thermal Mass: 181 sqft Exposed Slab Floor, 3.50" thick at Zone 1 HIGH MASS Design - Thermal Mass: 173 sqft Exposed Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design - Thermal Mass: 1096 sqft Covered Slab Floor, 3.50" thick at Zone 1 HIGH MASS Design - Thermal Mass: 153 sqft Covered Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design - Thermal Mass: 922 sqft Exposed Slab Floor, 4.00" thick at Zone 2 HIGH MASS Design - Thermal Mass: 656 sqft Exposed Slab Floor, 3.50" thick at Zone 2 I r� HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods.Pla�ield EnerovPro 4.4 by EnengvSoft User Number: 5732 Job Number: Ig010409 Page:7 of 12 1 I r� i EnerovPro 4.4 by EnengvSoft User Number: 5732 Job Number: Ig010409 Page:7 of 12 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ 0 ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ Q ❑ apply to exterior mass walls). ❑ ❑X ❑ �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. 1. Masonry and factory -built fireplaces have: Q ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. ❑ .a. closable metal or glass door covering the entire opening of the firebox ❑ Q ❑ Q b. outside air intake with damper and control, flue damper and control ❑ Q ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ; ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ Q ❑ 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and CF -6R Form: ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed Coefficient (SHGC), and infiltration certification. ❑ Q ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑x ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ Q ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. ❑ Q ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ Q ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig010409 Page:8 of 12 Mandatory Measures Summary: Residential (Page.2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ® ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ® ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater,,weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36' of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ © ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ® ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft� OR are controlled by a dimmer switch OR are controlled ❑ © ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. r § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ © ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/Water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig010409 Page:9 of 12 Residential Kitchen Lighting. Worksheet WS -5R Mr. Bob Hull 3/5/2009 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-0. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts 1 26w Compact Fluorescent Triple Pin Yes X No - 28.0 x 8 = 224 or Recessed Incandescent Yes I NoX 40.0 x 3 = or 120 Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes JNo x = or Yes x = or Yes x = or Yes x = or Yes x = or Yes x = or Yes No x = or Yes No x = or Yes -No x = or Yes I No x = or Yes No x = or Yes No x = or YesNo x = or Yes No x = or Total A: 224 B: 120 COMPLIES IF A >_ B YES ® NO ❑ l EnergyPro 4.4 by EnergySofl User Number: 5732 Job Number: Ig010409 Page: 10 of 12 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Mr. Bob Hull 3/5/2009 SYSTEM NAME FLOOR AREA HVAC System - ZONE 1 1,603 EATING SYSTEM PSYCHROMETRICS Airst 26.0 OF 69.0 OF . Outside Air 0 cfm 69.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I CFM I Sensible 692 18,401 2,030 414 14,872 0 2,517 1,629 0 0 0 0 0 0 0 1,790 -1,790 2,517 1,629 25 22 2 030 16 339 Day & Night - PAN46000OK00A 49,343 0 59,000 Total Adjusted System Output 49,343 OI 59,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug2 prn I Jan 12 am 103.7 of Heating Coil Supply Fan 1600 cfm 104.7 of -� Supply Air Ducts 103.80F ROOMS 70.0 of �% Return Air Ducts `i COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 111.0/77.6 OF 79.5/60.9 OF . 50.5/49.0 OF 51.6/49.5 OF Outside Air 0 cfm 79.5/60.9 ° F Cooling Coil Supply Alr Ducts Supply Fan 53.0 / 50.1 of 1600 cfm 35.4% R.H. ROOMS 78.0/60.4OF Return Air Ducts I I EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig010409 Page: 11 of 12 I HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Mr. Bob Hull 3/5/2009 SYSTEM NAME FLOOR AREA HVAC System -ZONE 2 1,578 Number of Systems 1 Heating System Output per System 59,000 Total Output (Btuh) 59,000 Output (Btuh/sqft) 37.4 Cooling System Output per System 59,000 Total Output (Btuh) 59,000 Total Output (Tons) 4.9 Total Output (Btuh/sqft) 37.4 Total Output (sgft/Ton) 320.9 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sqft) 1.01 Airflow (cfm/Ton) 325.4 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions :ATING SYSTEM 26.0 OF Outside Air 0 cfm 69.0 of COOLING SYSTEM 111.0 / 77.6 of Outside Air 0 cfm 79.5/60.9 ° F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 18,738 CFM I Sensiblel Latent �COILHTG.PEAK I CFM I Sensible 706 18,738 2,011 449 16,057 0 2,563 1,758 0 0 0 0 0 0 0 1,790 -1,790 2,5631 1,758 25,654T_2,011 17 784 HVAC EQUIPMENT SELECTION Day & Night - PAN460000KOOA 49,353 0 59,000 Total Adjusted System Output49,353 0 59,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug2 prn Jan 12 am RICS (Airstream Ter 69.OcF = 103.60F Heating Coil irstream T 79.5/60.9OF at Time of 104.7 of Supply Air Ducts Supply Fan 103.6 of 1600 cfm ROOM S 70.0 of of Cool 50.5/49.0OF 51.6/49.5OF FL Supply Air Ducts Supply Fan 53.1 / 50.1 of 1600 cfm 35.4% R.H. ROOMS 78.0/60.4OF Cooling Coil Return Air Ducts EnergyPro 4.4 by EnergySoft User Number: 5732 Job Number: Ig010409 Page:12 of 12 —1