11-0209 (RER)P.O. BOX 1504
78-495 CALLE TAMPICO -
LA QUINTA,-CALIFORNIA 92253
Application Number: X11-0000020
Property Address: 53521 AVENIDA VELASCO
APN: 774-124-026-2 -000.000-
Application description: REMODEL'- RESIDENTIAL
Property Zoning: COVE RESIDENTIAL
Application valuation: 45000
Applicant:
T4ht
"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Architect or Engineer:
Owner:
SPRUEILL NOELLE A
53-521 AVENIDA VELASCO
LA QUINTA, CA 92253
Contractor:
PIKE BUILDERS/DEVEL
77305 MINNESOTA AVE
PALM DESERT, CA 922
(760)851-9998
Lic. No.: 766896
VOICE (760) 777-7012.
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 4/22/11
MIKE
f 2011
pYnc
— — — - — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - — — — — — — — — — — —
LICENSED CONTRACTOR'S DECLARATION
— —
- --------------- - -----------------------------
----------------------------LICENSED
- WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
I hereby affirm under penalty of perjury one of the following declarations:
Section 7000) of Division 3' of the Business and Professionals Code, and my License is in full force and effect.
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
License Class: B License No.: 766896
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
-Date:J�yContractor: ; -
issued.
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
tCode, for is issued. My
OWNER -BUILDER DECLARATIONinsurance
for the performance of the work which this permit workers' cbmpensation
carrier and policy number are:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
Carrier EXEMPT - Policy Number EXEMPT
following reason (Sec: 7031 .5, Business and Professions Code: Any city or county that requires a permit to
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
person in any manner so as to become subject to the workers' compensation laws of California,
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
and agree that, if I should become subject to the workers' compensation provisions of Section
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
3700 of the Labor Code, I shall forthwith comply witp those provisions.
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($ 500).:
Date: —49;.%'l Appjicant:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
t
•---- - '-- - - '
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
Contractors' State License Law does not apply to an owner of property who builds or improves thereon, -
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
and who does .the work himself or herself through his or her own employees, provided that the
DOLLARS ($100,000). IN ADDITION TO THE COST•OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
'improvements are not intended or offered for sale: If, however, the building or improvement is sold within
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
.
improve for the purpose of sale.). -
APPLICANT ACKNOWLEDGEMENT
(_) 'l, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
conditions and restrictions set forth on this application.
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
1. Each person upon whose behalf this application is made, each person at whose request and for
- pursuant to the Contractors' State License Law.).
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
(_) I am exempt under Sec. , B.&P.C. for this reason
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the.City
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ: C.).
. Lender's Name:
Lender's Address:
of La Ouinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
'within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon.the above-mentioned properttyyfor
rii-nspe/c/tii purpooss�ees.
.Date: 7JntD' / Sig, nature (Applicant or Agent): •-%r"!�/'C�C/y (� ��::^C/�=��.��
LQPERMIT - -
+ /II
Application Number
-11-00000209
------ Structure Information 303SF ADD&REMODEL/VB/RES-3/CL-A
[ENG] --.---
Other struct info
CODE EDITION 2010•
# BEDROOMS
1.00
Permit BUILDING PERMIT
-
Additional desc
.
'Permit'Fee
382.00 Plan Check Fee
248.30
Issue Date
Valuation . . . .
45000
Expiration Date
10/19/11
Qty Unit Charge
Per.
Extension
"
BASE "FEE
252.00
20:00 6.5000
THOU BLDG 25,001-50,000
130.00
• Permit . . . ELECT _ ADD/ALT/REM
Additional desc .
Permit.Fee
42.41 Plan Check Fee
10.60
Issue Date
Valuation
0
'Expiration Date
.10/19/11"
Qty Unit Charge
Per
Extension
BASE FEE
303.00 ..•0350
ELEC NEW RES - 1 OR 2 FAMILY
10.61
20.00 .7500
PER ' ELEC DEVICE/FIXTURE 1ST 20,
15.00
4.00 .4500"
----------------------------------------------------------------------------
, EA ELEC DEVICE/FIXTURE >20'
1.80
Permit . . . MECHANICAL
Additional desc .
Permit.Fee
32.50, Plan Check Fee
8.13.
Issue Date . . .
Valuation
0
Expiration Date -
10/19/11
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 4.5000
EA MECH VENT INST/ DUCT ALT
4.50.
2.00 6:5000
EA MECH VENT FAN
13.00
Permit
PLUMBING
Additional desc .
Permit Fee . . . .
66.00 Plan Check Fee `.
16.50
Issue, Date:
Valuation
0
. Expiration Date
10/19/11
Qty Unit Charge
Per.
Extension
LQPERMIT
.
Application Number 11-00000209-
1-00000209Permit.
Permit.PLUMBING
Qty Unit Charge Per
Extension
BASE'FEE
15.00
8.00 6.0000 EA PLB FIXTURE
48.00
1.00 3:.0000 EA PLB WATER INST/ALT/REP
3.00
---------------
Special Notes and Comments
303SF.ADDITION WITH REMODEL AT EXISTING
RESIDENCE/VB/RES-3/CLASS'A-FR [ENG] THIS
PERMIT DOES NOT INCLUDE PATIO COVER,
ONLY REDUCTION TO EXISTING. 2010
CALIFORNIA BUILDING CODES.
April 14_201i 5:11:27 PM AORTEGA
---------
--- -- - - --
-----------------------------------------------------
Other Fees . . . . .. . . . BLDG STDS ADMIN (SB1473)
_
2.00
ENERGY REVIEW FEE
24.83
STRONG MOTION (SMI) - RES
4.50
Fee summary Charged Paid Credited
------- ----
Due
----------------- ----------
Fee Total 522.91 .00 .00
522.91
Plan Check Total 283.53 .00 .00-
283.53
Other Fee Total- 31.33 .00 .00
31.33
Grand Total 837.77 .00 .00
837.77
LQPERMIT ,
Bi
City of La Quint'a
Building &r Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address: 53521 Nevio,4 VF,l,E-sco
A. P. Number: — .2 2tQ
Legal Description: �Q�j'' 2�
Contractor:
Owner's Name: Joe" s Ue u —
Address: 5�z MIE�NlDk
City, ST, Zip
JAQ01 Krk CAC 225
Telephone: b 8 3-746n
Address:
Project Description: 1�>ti1v 1oQC/l.tN6Q
.
City, ST, Zip:
Telephone:y:?<%a•>`:.>"'>'•'•r
»;<%'s<<
:::4 ::::: $:::::::: $ .:$:.::::.$yA..
:.....::::.:::...:: :..:.:::::..:::.:$...
::.City
;.::::.•
�NV�(6N of M . � w i
State Lie. # :
Lie. #.
Arch., Engr., Desi ner: J Q
Address:
City, ST, Zip:j3
Telephone: �Jr ;:ry4.yt#i.>:
•'•>.;,::.;:.:,•::::.:.....::.:...:.: s$:..:
0� t:i:ii$f•:Y:Skil>$$$$i}:.:n A•;iyi$:ti$:r:,ir>ii.CY$�
State Lie. #: .'.:.'s>-•:> :•::•:<;:-: :''$»%:;:::z:.>•$:>::z::
:;:;;:v;•:<>::$:a::>:st:>::;$:.>;;:.;::.::w>:
Name of Contact Person: ® M
Construction Type:
YP � Occupancy; K3.
• pro'ect a circle one : N w
J tYP ) e Add'n Alter Repair Demo
Sq. Ft.: 3CO # Stories: I # Units:
Telephone # of Contact Person: ? - 4� -
Estimated Value of Project: �,� •� ��
APPLICANT:
DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted g
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person'
I
Plan Check Balance
Title 24 Calcs.
Plans picked up A'." !� � (�
Construction
Flood plain plan
Plans resubmitted rj
Mechanical
Grading plan
2pd Review, ready for correctionss a
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for correctio issue
Developer Impact Fee
PlanningApproval PP
Called Contact Person
A.I.P.P. .
Pub. Wks. Appr
Date of permit issue
School Fees
r,
Total Permit Fees
I Sin X17
3V�ftt, - its of'-.[sc4ruc. (ate. moo)
-a ,g,e��X11 �.�
�Guc. � -!3 -- l
iJ�
CERTIFICATE OF COMPLIANCE 4�J 21FDk_o
Desert Sands Unified School District
47950 Dune Palms Road ¢ BERMUDA DUNES r
RANCHO MIRAGE rJ
Date 4/22/11. La Quinta, CA 92253 INDIAN WELLS
No. 30968 (760) 771-8515 dLM DESERT
. , P nUINTA el
,,Y QINDIO y�
O
Owner Noelle Sprueill APN # 774-124-026
Address 53521 Avenida Velasco Jurisdiction La Quinta
City La Quinta Zip Permit #
Tract # No. of Units 1
Type Residential Addition
Lot # No. Street S.F. Lot # 'No. Street S.F.
Unit 1 53521 Avenida Velasco 303 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit,5 Unit 10
Comments
At the present time, the -Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for Irving, sleeping, cooking; eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 303 'S.F. or $0.00 have been paid for'the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Noelle Sprueill Check No.
Name on the check Telephone 760-899-3746
Funding Exempt
BY Dr. Sharon P. McGehee
Superintendent
Fee collected /exemptetf by Shar
Signature
V s .
Payment Recd = $0.00
Over/USldi
r.
NOTICE: Pursuant to Government Code. Section 66020(d)(1), this 411 s9ke to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on YAirch the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Spueill Residence
53521 Avenida Velesco
La Quinta, CA
Project Designer:
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77-810 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
760-345-1352
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED Job Number: 1�EC�IVED ;
FOR CONSTRUCTION
1
DATE 4 `�y d'a'l BY Date: MAR 3 0 2011
3/29/2011
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use; with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro5.1 by Ener Soft User Number: 2655 RunCode:2011-03-29711:49:47 /D:
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 10
HVAC System Heating and Cooling Loads Summary 13
EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 2655
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Spueill Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
3/29/2011
Project Address
53521 Avenida Velesco La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,343
Addition
303
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade
None 2,040 Perim = 220' Existing
Wall Wood Framed
R-11 1,266 Existing
Door Opaque Door
None 20 Existing
Roof Wood Framed Attic
R-22 2,040 Existing
Wall Wood Framed
R-13 235 New
Roof Wood Framed Attic
R-38 303 New
Slab Unheated Slab -on -Grade
None 303 Perim = 18' New
FENESTRATION U-
Orientation Area Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (E) 13.3 0.710
0.73 2.0 none Bug Screen Existing
Front (E) 24.0 0.710
0.73 2.0 none Bug Screen Existing
Front (E) 32.0 0.710
0.73 2.0 none Bug Screen Existing
Front (E) 24.0 0.710
0.73 2.0 none Bug Screen Existing
Left (S) 24.0 0.710
0.73 2.0 none Bug Screen Existing
Rear (W) 4.0 0.710
0.73 2.0 none Bug Screen Existing
Rear (W) 32.0 0.710
0.73 2.0 none Bug Screen Existing
Rear (W) 15.0 0.710
0.73 2.0 none Bug Screen Existing
Right (N) 32.0 0.710
0.73 2.0 none Bug Screen Existing
Right (N) 24.0 0.710
0.73 2.0 none Bug Screen Existing
Rear (W) 60.0 0.590
0.45 3.0 none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Existing House Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 201 1-03-29 711:49:47 ID:
Page 3 of 13
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Spueill Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
3/29/2011
Project Address
53521 Avenida Velesco La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,343
Addition
303
# of Stories
1 1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Rear (tM 10.0 0.590 0.45 3.0 none Bug Screen New
Rear (tM 4.7 0.590 0.45 3.0 none Bug Screen New
Rear (tM 4.7 0.590 0.45 3.0 none Bug Screen New
Rear (IM 15.0 0.590 0.45 3.0 none Bug Screen New
Rear (IM 15.0 0.590 0.45 3.0 none Bug Screen New
Right (N) 20.0 0.590 0.45 10.0 none Bug Screen New
Right (N) 20.0 0.590 0.45 10.0 none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro6l by EneTySoft User Number.' 2655 RunCode: 2011-03-29711:49:47 ID:
Pa e 4 of 13
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R
Project Name
Spueill Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family 10 Existing+ Addition/Alteration
Date
3/29/2011
SPECIAL FEATURES -INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation; and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each of the measures listed below for final to be given.
EnerqyPro 5.1 by Ene Soft User Number: 2655 RunCode: 2011-03-29T1 1:49:47 ID: Page 5 of 13
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Spueill Residence
1 ❑ Multi Family 10 Existing+ Addition/Alteration
1312912011
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 7.65 7.42 0.23
Space Cooling 120.67 119.44 1.22
Fans 26.55 26.25 0.30
Domestic Hot Water 16.89 16.89 0.00
Pumps 0.00 0.00 0.00
Totals 171.75 170.00 1.76
Percent Better Than Standard: 1.0
BUILDING COMPLIES.- NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 320 93
Fuel Available at Site: Natural Gas (S) 532 24
Raised Floor Area: 0 (w) 570 160
Slab on Grade Area: 2,343 (N) 472 96
Average Ceiling Height: 8.0 Roof 2,343 0
Fenestration Average U -Factor: 0.66 TOTAL: 374
Average SHGC: 0.62 Fenestration/CFA Ratio: 15.9%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author .
Company Insu-form, Inc.
312 201
Address 77-810 Las Montanas Road, Suite 201 Name Joan D. Hacker IAti tA
Cit State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Si Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer o. r Owner (per Business & Professions Code)
Company ,
Jo 1 t
��
Address Name W
City/State/Zip Phone?�I % ed License # D to
Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2011-03-29T11:49:47 ID: Page 6 of 13
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5) CF -1 R
Project Name
SpueDl Residence
Building Type m Single Family ❑ Addition Alone -
❑Multi Family m Existing+ Addition/Alteration
Date
3/29/2011
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation
Factor Cavity Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status - 4 Location/Comments
Slab
2,040
0.730 None
0
180 Existing 4.4.7-A1
Existing House '
Wall
207
0.110 R-11
90
90 Existing 4.3.1-A2
Existing House
Door
20
1.450 None
90
90 Existing 4.5.1-A1-
Existing House
Wall
396
0.110 R-11
180
90 Existing 4.3.1-A2
Existing House
Wall
359
0.110 R-11
270
90 Existing 4.3.1-A2
Existinq House
Wall
304
0.110 R-11
0
90 Existing 4.3.1-A2
Existing House .
Roof
2,040
0.043 R-22
90
0 Existing 4.2.1-A6
Existing House
Wall
360
0.110 R-11
270
90 Removec 4.3.1-A2
Existing House
Wall
112
0.102 R-13
180
90 New 4.3.1-A3
Addition
Roof
303
0.025 R-38
90
0 New 4.2.1-A21
Addition
Wall
51
0.102 R-13
270
90 New 4.3.1-A3
Addition
Slab
303
0.730 None
0
180 New 4.4.7-A 1
Addition
Wall
'72
0.102 R-13
0
90 New 4.3.1-A3
Addition
FENESTRATION SURFACE DETAILS
ID
Tvve
Area LI -Factor'
SHGC2
Azm Status
Glazing Type
Location/Comments
1
Window
13.3 0.710 1 Default
0.73 Default
90 Existing
Double Metal Clear
Existing House
2
Window
24.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing House
3
Window
32.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing House
4
Window
24.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing House
5
Window
24.0 0.710 Default
0.73 Default
1801 Existing
Double Metal Clear
Existing House
6
Window
53.4 0.710 Default
0.73 Default
270 Removed Double Metal Clear
Existing House
7
Window
4.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing House
8
Window
32.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing House
9
Window
15.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing House
10
Window
32.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing House
11
Window
24.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing House
12
Window
25.0 0.590 NFRC
0.45 NFRC
270 New
IWC 6200 Alum/Low-E
Addition
13
Window 1
10.01 0.590 NFRC
0.45 1 NFRC
270 New
IWC 6200 Alum/Low-E
Addition
14
Window 1
25.01 0. 5901 NFRC
0.45 NFRC
270 New
IWC 6200 Alurnkow-E
Addition
15
Window 1
10.01 0. 5901 NFRC
0.45 NFRC
270 New
IWC 6200 Alum/Low-E
Addition
16
Window -1
4.71 0. 5901 NFRC
0.45 1 NFRC
270 New
IWC 6200 Alum/Low-E
Addition
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hang Left Fin Right Fin
Len I H t LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76
6.8 1.0
2.0 0.1
2.0 2.0
2
Bug Screen
0.76
4.0 6.0
2.0 0.1
2.0 2.0
3
Bug Screen
0.76
4.0 8.0
2.0 0.1
2.0 2.0
4
Bug Screen
0.76
4.0 6.0
2.0 0.1
2.0 2.0
5
Bug Screen
0.76
4.0 6.0
2.0 0.1
2.0 2.0
6
Bug Screen
0.76 ' 6.8 8.0
2.0 0.1
2.01 2.0 .
7
Bug Screen
0.76
1.0 4.0
2.0 0.1
2.0 2.0
8
Bug Screen
. 0.76
4.0 8.0
2.0 0.1
2.0 2.0
9
Bug Screen
0.76
3.0 5.0
2.0 0.1
2.0 2.0
10
Bug Screen
0.76
4.0 8.0
2.0 0.1
2.0 2.0
11
Bug Screen
0.76
4.0 6.0
2.0 0.1
2.0 2.0
12
Bug Screen
0.76
5.0 5.0
3.0 0.1
3.0 3.0
13
Bug Screen
0.76
5.0 2.0
3.0 0.1
3.0 3.0
14
_Bug Screen
0.76
5.01 5.0
3.0 0.1
3.0 3.0
15
JBug Screen
0.76
5.01 2.0
3.01 0.1
3.01 3.0
16
18ug Screen
1 .0.76
2.01
3.01 0.1
3.01 3.0
Ene
Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2011-03-29T11:49:47 ID:
Page 7 of 11
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Spueill Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1312912011
OPAQUE SURFACE DETAILS
Surface U-
Tvpe Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area
U -Factor SHGC2
Azm Status Glazing Type Location/Comments
17 Window 4.7
0.590 NFRC 0.45 NFRC 270 New IWC 6200 Alum/Low-E Addition
18 Window 15.0
0.590 NFRC 0.45 NFRC 270 New IWC 6200 Alum/Low-E Addition
19 Window 15.0
0.590 NFRC 0.45 NFRC 270 New IWC 6200 Alurnkow-E Addition
20 Window 20.0
0.590 NFRC 0.45 NFRC 0 New IWC 6200 Alurnkow-E Addition
21 Window 20.0
0.590 NFRC 0.45 NFRC 0 New IWC 6200 Alum/Low-E Addition
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID Exterior Shade Type
Window
SHGC H t Wd
Ove hang Left Fin Right Fin
Len Hot LExt I RExt Dist Len H t Dist Len H t
17 Bug Screen
0.76 2.0 1.4 3.0 0.1 3.0 3.0
18 Bug Screen
0.76 5.0 3.0 3.0 0.1 3.0 3.0
19 Bug Screen
0.76 5.0 3.0 3.0 0.1 3.0 3.0
20 Bug Screen
0.76 6.8 3.01 10.0 0.1 10.0 10.0
21 Bug Screen
0.76 6.8 3.0 10.0 0.1 10.0 10.0
EnerqyPro 5.1 by EnerqySoft
User Number: 2655
RunCode: 2011-03-29711:49:47 ID: Page 8 of 13
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
Spueill Residence
Building Type la Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
3/29/2011
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Existing Altered Removed Volume Year Built
Existing House Existing House
2040
16,320 1980
Addition
303
2,424
Totals 1 303 Z0401 01 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Existing House 1 Central Furnace
80% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Coolin Duct Location R -Value
Ducts
Tested? Status
Existing House Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
No Pipe Insulation
40,000
50
0.53
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ft
0
_ o
v
Q —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty.
HP
Plenum Outside Buried
01
Ener Pro 5.1 by EnergySoft User Number: 2655
RunCode: 2011-03-29711:49:47 ID:
Pae 9 of 13
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Spueill Residence
Date
3/29/2011
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 Oc : Minimum R-13 insulation in wood -frame wall orequivalent LI -factor.
*§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent LI -facto r.
150(f): Air retarding wrap is tested labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 (e)1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)113: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight-titting tight-fittingdamper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation havino an installed thermal resistance of R-12 or greater.
§1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A. '
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number.- 2655 RunCode: 2011-03-29711:49:47 ID: Page 10 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Spueill Residence
3/29/2011
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2011-03-29711:49:47 ID: Page 11 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Spueill Residence
3/29/2011
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130 131 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2011-03-29711:49:47 ID: Page 12 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Spueill Residence
Date
3/29/2011
System Name
Existing House
Floor Area
2,343
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,224
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent I CFM
Sensible
Output per System 70,000
39,240
3,255 757
37,643
Total Output Btuh 70,000
0
Output Btuh/s ft 29.9
3,327
2,674
Cooling System
0
0
Output per System 58,000
0
0 0
0
Total Output Btuh 58,000
0
3,255
0
Total Output Tons 4.8
3,327
2,674
Total Output Btuh/s ft 24.8
Total Output s ft/Ton 484.8
1 45,895
42,992
Air System
CFM per System
1,300
HVAC EQUIPMENT SELECTION
Airflow cfm
1,300
D & N HPNFC P6000A1 47,220
0
70,000
Airflow cfm/s ft
0.55
Airflow cfm/Ton
269.0
Outside kr % 0.0%
Total Adjusted System Output 47,220
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0
Aug 3 PM
70,000
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions I
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 °F 68 OF
Outside Air
0 cfm Supply Fan
AL 1,300 cfm
68 OF
68 OF 119 OF
Heating Coil
117 OF
ROOM:
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 80/59°F
Outside Air
0 cfm
80/59°F
80/60°F 46/44°F
Supply Fan Cooling Coil 48 / 45 OF
1,300 cfm
30.6 ROOM
78/59°F
I
EnergyPro5.1 by EnergySoff User Number: 2655 RunCode: 2011-03-29711:49:47 ID:
Page 13 of 13
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Spueill Residence .
53521 Avenida Velesco
La Quinta; CA..
:Project Designer:
Report Prepared by;
Joan D. Hacker
Insu-form, Inc.
77-810 Las Montanas Road, Suite 201
Palm Desert, Ca 92211.
760-345-1352
Date:
6/29/2011
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by.the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com.
EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2011-06-29T15:24:58 Q
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF-113
Project Name
Spueill Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
6%29/2011
Project Address
53521 Avenida Velesco La Quinta
California Energy Climate Zone
CA Climate Zone 15
I Total Cond. Floor Area
2,343
Addition
303
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features (see Part 2 of 5) Status
Slab Unheated Slab-on-Grade None 2040 Perim = 220' Existing
well Wood Framed R-11 1,266 Existing
Door Opaque Door None 20 Existing
Roof Wood Framed Attic R-22 2040 Existing
Wall Wood Framed R-13 284 New
Roof Wood Framed Attic R-38 303 New
Slab Unheated Slab-on-Grade None 303 Perim = 18' New
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Front (E) 13.3 0.710
0.73 2.0 none Bug Screen Existing
Front (E) 24.0 0.710
0.73 2.0 none Bug Screen Existing
Front (E) 32.0 0.710
0.73 2.0 none Bug Screen Existing
Front (E) 24.0 0.710
0.73 2.0 none Bug Screen Existing
Left(S) 24.0 0.710
0.73 2.0 none Bug Screen Existing
Rear (W) 4.0 0.710
0.73 2.0 none Bug Screen Existing
Rear (W) 32.0 0.710
0.73 2.0 none Bug Screen Existing
Rear (149 15.0 0.710 0.73 2.0 none Bug Screen Existing
Right (N) 32.0 0.710 0.73 2.0 none Bug Screen Existing
Right (N) 24.0 0.710
0.73 2.0 none Bug Screen Existing
Rear (Kg 80.0 0.590 0.45 3.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 12.0 SEER Setback ExWing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
Existing House Ducted
Ducted Attic; Ceiling Ins, vented 4.2 Existing
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
EneryWro 5.1 by EnergySoft User Number. 2655
RunCode. 2011-06-29T15:24.58 ID:
Page 3 of 12
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Spueill Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration 1612912011
Date
Project Address
53521 Avenida Velesco La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,343
Addition
303
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (ft) Features (see Part 2 of 5) Status
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Right (N) 10.0 0.590 0.45 10.0 none Bug Screen New
Right (N) 10.0 0.590 0.45 10.0 none Bug Screen New
HVAC SYSTEMS
City. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2011-06-29T15:24:56 ID:
Pe e 4 of 12
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -113
Project Name
Spueill Residence
Building Type ® Single Family ❑ Addition Alone
1 ❑ Multi Family ® Existing+ Addition/Alteration
Date
6129/2011
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -413 form for each of the measures listed below for final to be given.
EnergyPro 5.1 by EnergySoff User Number. 2655 RunCode. 2011-06-29T15.24:58 ID. Page 5 of 12
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Spueill Residence
I O Multi Family ' m Existing+ Addition/Alteration
1612912011
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 7.65 6.89 0.76
Space Cooling 120.67 117.43 3.24
Fans 26.55 25.79 0.76
Domestic Hot Water 16.89 16.89 0.00
Pumps 0.00 0.00 0.00
Totals 171.75 167.00 4.75
Percent Better Than Standard: 2.8%
BUILDING COMPLIES -NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 320 93
Fuel Available at Site: Natural Gas (S) 532 24
Raised Floor Area: 0 (M 570 131
Slab on Grade Area: 2,343 (N) 472 76
Average Ceiling Height: s.0 Root 2,343 0
Fenestration Average U -Factor: 0.67 TOTAL: 324
Average SHGC: 0.64 Fenestration/CFA Ratio: 13.8%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc.
6/29/2011
Address 77-810 Las Montanas Road, Suite 201 Name Joan D. Hacker
City/State/ZipCity/State/Zip Palm Desert. Ca 92211 Phone. 760-345-1352 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company
�
C''�
Address Name .
City/State2p . Phone Sig License # Date
Ener Pro 5.1 b v Ener Soft User Number- 2655 RunCode: 2011-06-29T15:24.•58 ID: Pa e 6 of 12
CERTIFICATE OF COMPLIANCE:
Residential
Part 4 of 5 'CF -1 R
Project Name
Spueill Residence
Building Type 0 Single Family 0 Addition Alone
❑ multi Family ® Existing+ Addition/Alteration
Date '
1612912011
OPAQUE SURFACE DETAILS
Surface
U- Insulation
Factor Cavity Exterior Frame Interior Frame Azm
Joint Appendix
Tift Status 4 Location/Comments
-TypeArea
Slab
Z040
0.730 None
0
180 Existing 4.4.7-A 1
Existing House
Wall
207
0.110 R-11
90
90 Existing 4.3.1-A2
Existing House
Door
20
1.450 None
90
90 Existing 4.5.1-A1
Existing House
Wall
396
0.110 R-11
180
90 Existing 4.3.1-A2
Existi House
Way
359
0.110 R-11
270
90 Existing 4.3.1-A2
Existing House
We//
304
0.110 R-11
0
90 Existin 4.3.1-A2
Existing House
Roof
2,040
0.043 R-22
90
0 Existing 4.2.1-A6-
Existing House
Wall
360
0.110 R-11
270
90 Removec 4.3.1-A2
Exfstin House
Wall
112
0.102 R-13
180
90 New 4.3.1-A3
Addition
Roof
303
0.025 R-38
90
0 New 4.2.1-A21
Addition
Slab
303
0.730 None
0
180 New 4.4.7-A1
Addition
Wall
80
0.102 R-13
270
90 New 4.3.1-A3
Addition
Wall
92
0.102 R-13
0
90 New 4.3.1-A3
Addition
FENESTRATION SURFACE DETAILS
ID
Type
Area LI -Factor'
SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
13.3 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing House
2
Window
24.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing House
3
Window
32.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing House
4
Window
24.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing House
5
Window
24.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing House
6
Window
53.4 0.710 Default
0.73 Default
270 Removed Double Metal Clear
Existing House
7
Window
4.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing House
8
Window
32.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing House
9
Window
15.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing House
10
Window
32.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing House
11
Window
24.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing House .
12
Window
80.0 0.590 NFRC
0.45 NFRC
270 New -
IWC 6200 Alum/Low-E
Addition
13
Window
10.01 0.590 NFRC
1 0.45 NFRC
0 New
IWC 6200 Aluinkow-E
Addition
14
Window
10.0 0.590 NFRC
0.45 NFRC
1 0 New
IWC 6200 Alunzkow-E
Addition
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC T 116-8 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
Hat Wd
Overhang Left Fin
Len H LExt . RExt Dist Len
Right Fin
H t Dist Len H t
1
Bug Screen
0.76
6.8 1.0
2.0 0.1
2.0 ' 2-0
2
Bug Screen
0.76
4.0 6.0
2.0 0.1
2.0 2.0
3
Bug Screen
0.76
4.0 8.0
2-0 0.1
2.0 2.0
4
Bug Screen
0.76
4.0 6.0
2.0 0.1
2.0 2.0
5
Bug Screen
-0.76
4.0 6.0
2.0 0.1 2.0 2.0
6
Bug Screen
0.76
6.81 8.0
2.0 0.1
2.0 2.0
7
Bug Screen
0.76
'1.0 4.0
2.0 0.1
2.0 2.0
8
Bug Screen
0.76
4.0 8.0
2.0 0.1
2.0 2.0
9
Bug Screen
0.76
3.0 5.0
2.0 0.1
20 20
10
Bug Screen
0.76
4.0 8.0
2.0 0.1
2.0 2.0
11
Bug Screen
0.76
4.0 .6.01
2.0 0.1
2.0 2.0
12
Bug Screen
0.76
6.8 12.0
3.0 0.1
3.0 3.0
13
Bug Screen
0.76
5.0 2.0
10.0 0.1 10.0 10.0
14
Bug Screen
0.76
5.0 2.0
10.0 0.1 10.0 10.0
EnergyPro
5.1 by EnergySoft User Number. 2655. RunCode: 2011-06-29T15:24:58 ID:
Page 7 of 12
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
Spueill Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
6/29/2011
BUILDING ZONE INFORMATION
System Name
Floor Area
Zone Name New Existing Altered Removed Volume Year Built
Existing House Existing House 2.040
16.320 1980
Addition 303
2.424
Totals 3031 2.0401 01 01
1
HVAC SYSTEMS
System Name
Oty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Existing House
1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name
Duct
Heating Cooling Duct Location R -Value
Ducts
Tested? Status
Existing House Ducted Ducted Attic. Ceiling Ins. vented 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Tvoe
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy Standby
Factor Loss or
or RE Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
No Pipe Insulation
40.000
50
0.53 We
We
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
_ o
io
QCo PLLenth
System Name
Pipe
Diameter
Insul.
Thick.
FHP
Plenum Outside Buried
O
Ener Pro 5.1 by Ener Soft
User Number: 2655 RunCode: 2011.06-29715:24:58 ID:
Page 8 of 12
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1R
Project Name
Spueill Residence
Date
6/29/2011
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
15O(e)IA: Mason or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox..
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible operable; and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building,are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1506)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1506)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§1506)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source -and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1 506)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoR User Number. 2655 RunCode: 2011-06-29715:24:58 ID: Page 9 of 12
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Spueiil Residence
6/29/2011
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light. '
§114(b)l : Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
1 50 : Residential pool systems or equipment meet the pump sizing, flow rate; piping, filters, and valve requirements of § 1 50 .
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket. '
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or.100 watts for dwelling units larger than 2,500 112 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet. '
EnergyPro5.1 by EnergySoff User Number.- 2655 RunCode: 2011-06-29715:24:58 ID: Page 10 of 12
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name .
Date
Spueill Residence
1612912011
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential.buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptions to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§ 150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode. 2011-06-29T15.24.58 ID: Page 11 of 12
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Spueill Residence
6/29/2011
System Name
Floor Area
Existing House
2,343
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK
CFM Sensible
Total Room Loads 1,183 37,950
Return Vented Lighting 0
Return Air Ducts 3,218
Return Fan 0
Ventilation F 0 0
Supply Fan 0
Supply Air Ducts 3.218
TOTAL SYSTEM LOAD 44,386
COIL HTG.
Latent CFM
3,255 734
0 0
3,255
PEAK
Heating System
Sensible
Output per System 70,000
36,583
Total Output (Btuh) 70,000
Output Btuh/ ft 29.9
2,599
Cooling System
0
Output per System 58,000
0
Total Output Btuh • 58.000
0
Total Output (Tons) 4.8
2,599
Total Output Btuh/ 24.8
Total Ou ut on 484.8
1 41,781
Air System
CFM per System
1,300
HVAC EQUIPMENT SELECTION
Airflow (cfm)
1,300
D & N HPNFC P6000A1 47,220
0
70,000
Airflow cfm/s
0.55
Airflow (cfm/Ton)
269.0
Total Adjusted System Output 1 47,220
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0 70,000
Aug 3 PM Jan 1 AM
Outside Air 9/6 0.0%
Outside Air cfm/ 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 68 IF
68 OF
119 z=
Outside Air
--"---
0 drn Supply Fan
Heating Coil
117 OF
AL 1,300 dm
ROOMY
68 OF
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 80/59°F 80/60°F 46/44°F
Outside Air
0 dm
Supply Fan
Cooling Coil
48 145 OF
1,300 cfm
_....__ .
30.6%
f ROOM
t
80159 OF
78/ 59 OF
4
H--T-T'-T -4
EnergyPro 5.1 by EnergySoff User Number. 2655 RunCode: 2011-06-29T15:24:58 ID:
Page 12 of 12