Loading...
12990 (SFD)4 9S P.O. BOX 1504 N o . 12990 Building 78-105 CALLE ESTADO Address 77 4) Calie Sonora LA QUINTA, CALIFORNIA 92253 Owner sterling Homes Mailing BUILDING: TYPE CONST. OCC. GRP. Address P.O. SOX 450 -10. A.P. Number 773-254-001 City Zi Tel. Lot 22 Block 11 Tia Quinta, CA2253 564-2866 Legal Description Contra8.0 ctor Project Description Lecl+rI Ventures, Inc. P.Q. Baas 450 City Zip Tela La Quinta, CA 92253 564-1866 State Lic. & Classif. 3 538535 City Lic. # 859 Arch., Engr., Designer Lendel Ventures ;Inc. Address Tel. Xavier Urbina City Zip State 635 _ Qn Mech. Lic. # r LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed unQer provisions of Chapter 9 mmencing with Section 7000) of Divisriorr3 0( the Business anC._Pr io s'o s,Code and icense is in full force and effect. �: i/ 1v/><' ?.� C` +L J.S � _ 6 ' or f 1i OWNER -BUILDER DEOCARATION VC C.:z I hereby affirm that I am exempt from the ontractor's License Law for the following reason: (Sec. 7031,?5, Business and Profession Code: Any city or county which requires a permit to construct%' alter, improve, demolish, r repair any structure, prior to its issuance also requires the applicant for such permit to rile :a signed statement that he is licensed pursuant to the provisions ol"the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above.. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip Sq. Ft. No. Size 1640 Stories New Add ❑ Alter ❑ No. Dw. Units Repair ❑ Demolition ❑ Permit includes 5' stucco wall - retainin, wall and pool to be separate. Pool; permit must be obtained prior to beginning 5' wail. Estimated Valuation $98, 918.00 PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. 17R _ rn Const. 635 _ Qn Mech. _ Sr, yn Electrical Plumbing 144_00 S.M.I. 9.90 Grading 20 . Aid Driveway Enc. -0- Infrastructure 2 , 12$, 24 A TOTAL 3,659.52 3,409.52 REMARKS {1y� yf 1 l ty ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES IST FL. SO. FT. @ $ UNITS COLL. AREA SLAB GRADE t� ROUGH PLUMB. YARD SPKLR SYSTEM 2ND FL. SO. FT. HEATING (ROUGH) STORAGE TANK FORMS MOBILEHOME SVC. BAR SINK POR. SO. FT. ® DUCT WORK ROCK STORAGE GAR. SQ. FT. @ POWER OUTLET ROOF DRAINS HEATING (FINAL) DRAINAGE PIPING CAR P. SQ. FT. @ GAS (FINAL) TEMP. POLE WALL SQ. FT. DRINKING FOUNTAIN. GROUT WATER HEATER URINAL SO FT @ FINAL INSP. ESTIMATED CONSTRUCTION VALUATION $ WATER SYSTEM WATER PIPING NOTE: N'ot t'o be used as property tax valuation GRADING cu. yd. plus x$ FLOOR DRAIN MECHANICAL FEES FINAL INSP. /a 7�j` ` WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRY TRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVS WATER CLOSET' COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. @ c BATH TUB SO. FT. @ c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID @ 11/4 c SEWAGE DISPOSAL SO.FT.GAR @ 3/ac HOUSE SEWER INSULATION/SOUND 2-3-0/3 GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE / PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR s SETBACK epGROUND PLUMBING�.�� UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE t� ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS tD.EWER OUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. A GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM $ GRADING cu. yd. plus x$ =$ LUMBER GR. FINAL INSP. /a 7�j` ` FRAMING _/�_(�3 C I FINAL INSP./2 2��(� /REMARKS: ROOFING `7 —/",3G� / GS G•� `7 3 X11 VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL —,13113 LATHING ^1311 3 `- MESH INSULATION/SOUND 2-3-0/3 FINISH GRADING FINAL INSPECTION 12 =�3 CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL p. ir W - FC..', ' Al 78-495 CALLE TAMPICO — LA QUINTA, CALIFORNIA 92253 -. 619 777-7000 of Tii�v� FAX (619) , 777-7101 December- 10, 1993 Vickie J. Durrett DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Hwy 111 Indio, CA 92201 Dear Vickie: The addresses of the following structures 'have been changed: APN #773-254-001, Lot 22, Block 11 Changed from_ 77-400 ` Calle Sonora to 77-405 _ Calle Sonora. APN #617-112-004, Lot 33, your invoice #12032 . Changed from 78-865 Horseshoe to 79-865 Horseshoe. Please note these changes and. feel free to- contact me if I may be of further. assistance. Thank you. Sincerely, BUIL ING AND SAFETY DEPARTMENT Kelly T Zle Counter Technician' MAILING ADDRESS = P.O. BOX 1504` - LA QUINTA, CALIFORNIA 92253• URBINA & ASSOCIATES 6370 anvil lake ave. sae dlepo, call.fornla 92119 4' PLANNING d ARCHITECTURE 6- 9 August -21,,. 1993 -6 " Mr . A . P . "-. Lench- Sterling Homes 'La Quinta, , Calif . - re: Tlan "B -4m" -, Beam.modification Dear :Skip Enclosed please find drawing X-1 showing the remedy for the incorrectly installed 4x1`2 beam. Asea 6x12 was called _ out, it is necessary to reinforce the beam installed. '- Please reinforce the -beam as shown. Please feel free to call if you have any questions. + Respect Itlly/,- - Xavier Urbina e SAN IDIBGU,• Fp, yllul (619) 2319-4636 . PROJECT SUM11ARY (MIC OPAS---4--0 E 15, INSULA, IT ON: HEATING SYSTEMS I CEILING ..... R-38 MAKE & MODEL - UNI.T'41 WALL.:....... R-19 RHEEM.RGDG-075AUER FLOOR ....... NA 60.5 MBH OUTPUT DUCT ....... 4.2 80.51 AFUE GLAZING ..... DOUBLE MAKE .& MODFL SKYLIGHT ... YES ** .1 SHADING ....• DRAPES ** MBH ;OUTPUT * CSE �.f3t1AL�MASS WAXER HEATING SYSTEMSS_ KITCHEN ......... 195 SF BATH ............. 15G ,' MAKE .& MODEL ENTRY/HALL ...... 25 A.O. SMITH PGS -040 HEARTH .......... 10 38 GAL * .00 .022 VB *... ....... .00 .f * 00 *00 *• 00 * .............00 „ *.............. 00 TOTAL SF 386 COMPLIANCE STATEMENT I CERTIFY•THAT THE CALCULATIONS" ONFORM WITH ALL THE REQUIREMENTS OF C.E.C. TITLE 24 FOR COMPLIANC WITH THE ENERGY'STANDARD ' I HERZBERGER/SALEHI ENGI 'EKING CERTIFICATE OF COMPLIANCEj.RESIDENTIAL Project Title ........... STERLING HOMES Project Address........ LA QUINTA LA QUINTA Dc,cumentation Author... ROCKY Company ................ HERZBERGER/SALEHI ENG. Telephone .............. (619) 239-4636 Comp-liance Method...... MIC.ROPAS4 by Ener Climate Zone........... 15 MICROPAS4 v4.01 File -G421 Wth-C User#-MP.0406 User-HERZBERGER mp, Inc. Page 1 CF -lit Date.... .. 04/23/9.3 Building Perm` -tom Plan -cec Data F e .0 ec Date 15592 Program -FORM CF -1R ALEHI ENG. Run -PLAN SW -1 GENERAL INFORMATION Conditioned Floor Area..... 1640 sf Building Type.............. Single Family.Detached Construction Type New Building Front Orientation. Front Facing 0 deg (N) Number of Dwelling Units... 1 Number of Stories.. ...... 1 Floor Construction Type.... Slab On Grade (Package D) BUILDING SHELLIINSULATION Component Insulation Assembly Type R -value U -Value Wall R-19. 0.065 Roof R-38 0.029 S1abEdge R-0 0.900 S1abEdge R-0 0:720 S1abEdge R-0 0.500 Loca ion/Comments. FRON ,` .BACK, - RIGHT, LEFT Attic OUTSIDE To O9tside To-0tside FENESTRATION . Over - Area U- # of IntE rior Exterior hang/' Framing Orientation (sf) Value Panes Sha ing Shading Fins Type Window Front (N) 107.0 0.750 2~ Dra es.Std Sun Screen Yes Metal Window Back (S) 17.0 0.920 1 Dra es.Wht None, Yes Wood Window Back (S) 4.0 0.560 2 Non None Yes None Window Back (S) 87.5 0.750 2 Dra es.Std Sun Screen Yes Metal Window Right (W) 16..0 0.750 2 Draes.Std None Yes Metal Window Right (W) 126.0 0.750 2 Dra es.Std Sun Screen Yes Metal Window Left (E) 58.0 0.750 2 Dra es.Std None Yes Metal Skylight Front (N). 8.0 0.700 2 Non None None Metal THERMAL MASS Area T ickness Type Exposed (sf) (in) Location/Comments S1abOnGrade No 1280 3.5 Covered SlabOnGrade Yes 195 3.5 KITCHEN/ NOOK S1abOnCrade Yes 156 3.5; BATH S1abOnGxade Yes 25 3.5 ENTRY/HALL SlabOndrade Yes 10 .3.5 HEARTH ZERTIFI.CATE OF COMPLIANCE: RESIDENTIAL Page 2 CF_ 1R Project Title........... STERLING HOMES Date. 04/23/93 MICROPAS4 v4.01 File -G421 Wth-C Z15S92 Program -FORM CF -1R User#-MP0406 User-HERZBERGER/SALEHI ENG. Run -PLAN SW -1 HVAC SY NEMS Minimum Duct Duct Thermostat' Equipment Type Efficiency Location- R -value Type -. Furnace _ 0.800 AFUE Attic R-4.2 Setback ACSplit 12.00 SEER Attic R-4.2 Setback WATER HEATING SYSTEMS Number Tank External. in ..Energy Size Insulation Tank Type Heater Type Distribution T pe System Factor (gal) R -value Storage Gas Standard 1 0.59 EF 38 R- '12 SPECIAL FEAT.UF ES/REMARKS A.O. :SMITH' PGS -040 38..0GA O _ ~ RHEEM RGDG-075AMGR 60500 BTU/ R 80.5% AFUE: RHEEM.RPMA-036JA 35600 BTU/IR 12.0 SEER._ 3RTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 - CF -1R coject Title.......... STERLING HOMES Date...... 04/23/93 MICROPAS4 v4.01 File -G421 Wth-CTZ 5S92 Program -FORM CF -1R User#-MP0406 User-HERZBERGER/S LEHI ENG. Run -PLAN SW -1 COMPLIANCE ST TEMENT This certificate Of -compliance lists the Duilding features and performance specifications needed to comply with Title -24, -Parts 1 and 6 of the California Code of Regulations,. and the administrative regulation, to implement them. This Cartificate has bee signed by the individual with overall design responsibility. When this certificate,of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is in icated in the. Special Features/ Remarks section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... STERLING HOMES Nape.... ROCKY Company. SAME Company. HERZBERGER/SALEHI ENG. Address. P.O.. BOX 450 Address. '303 A STREET #409 LA QUINT CA 92253 SAN DIEGO, CA'.92101 Phone.:: 564-186 Ph no... (619) 239-4636 Signed.. - `l - O '� cls Si ned. d ( te) 7 - ( ate) /NF.ORCE . MENT AGEN Name.. Title. Agency:. Phone:.. Signed.. (de-te} MANDATORY MEASURES.CHECKLIST: RESIDENTIALI Page 1 MF. -1R Project Title. STERLING HOMES, Project Address........ LA QUINTA LA QUINTA Documentation Author... -ROCKY Company ................ HERZBERGER/SALEIII Telephone:..............(619) 239-4636 Compliance Method...... MICROPAS4 by E.ne Climate Zone........... 15 ENG. :omp, Inc. Date........ 04/23/93 Building Permit Plan. 'C ec Date Field CheckTDate MICROPAS4 v4.01' File -G421 Wth-CTZ15S92 Program -FORM MF -1R User#-MP0406 User-HERZBERGER�SALEHI ENG. Run -PLAN SW -1 Lowrise residential buildings subject measures regardless ofthe compliance a asterisk (*) may be superscdad by more st on the Certificate of Compliance. When t permit dornmants, the. features noted sh binding minimum component performance spe whether they are shown elsewhere in the d o the Standards. must contain these proach used. Items marked with an ingent compliance requirements listed is checklist is incorporated into the 11 be considered by all" parties as ifications for the mandatory measures cuments or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforee- *150(a): Minimum R-19 ceiling insulation. er. ment 150(b): Loose fill insulation manufacturers *150(c): Minimum R-13 wall insulation in -labeled R -Value. (does riot apply to exterior mass walls,. 0(d): rained walls Minimum R-13 raised floor insulation minimum R-0 in in framed floors; concrete raised floors. 150(i): Slab edge insulation - J_ water abs.rption than 0.3%, watervapor transmission rate no greater rate perm/inch. no greater than 2.0 118: Insulation specified -or installed meets standards. Indicate t CEC quality 116-17: Fenestration ProductsI , Exterior oors and Infiltration/ exfiltration controls, a. Doors and windows between condition d and unconditioned spaces desiped to limit air leakag . b. Manufactured fenestration products ave label with certified U -value, and infiltration certification. C. Exterior doors and windows weathers ripped; all joints and penetrations caulked and sealed 150(?): Vapor barriers mandatory in Climate Zones 14 and 16 y. 150(f):.Special *infiltration barrier installed to coin 1 with � Sec. 151 meets CEC quality standards. p y _150(e): Installation of -Fireplaces, Decorative Gas Appliances and gas logs 1:. Masonry and factory -built fireplace have: a. Closeable metal or glass door b. Outside air intake with damper and control C. Flue damper and control 2. No continuous burning gas pilots allowed. ~ v, c J Jr 7 tt tlth CdtkGtK% ;;HLEH 1 ENGINEERING MANDATORY MEASURES CHECKLISTt RESIDENTIAL Project Title.......... STERLING HOMES Page 2 uaze........ 04/23/93 MICROPAS4 v4.01 File -6421 Wth-C215S92 Program -FORM MF -1R User#-MP0406 User-HERZBERGER/SALEHI ENG Run -PLAN SW -1 SPACE CONDITIONING, _WATER _HEATING LAND PLUMBING SYSTEM MEASURES Design- Enforce - 110 -13: HVAC equipment, water heaterss owerheads and faucets,er ment certified by the CEC. , 150(1), Setback thermostat on all applic bld heating systems. 150(j)t Pipe and Tank insulation. 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have nsulation blanket (R-12 or greater) or combined interior/ex erior. insulation (R-16 or greater). 2, First 5 feet of pipes closest to wa er heater tank, non - recirculating systems, insulated (R 4 or greater). 3. All buried or exposed piping insula ed in recirculating sections of hot water system. 4..Coolinq system pipi,ng.below, 55 degr es insulated. 5� Piping insulated between heating so rce.and indirect hot water rank. *150(m): Ducts and Fans 1. Ducts constructed; installed and se led to comply with UMC Section s.1.002 and 1004; ducts insul:ted to a minimum ..installed value of R-4.2 or ducts a closed entirely within conditioned spa,,:, . 2• Exhaust fan systems have backdraft. r automatic dampers. 3. Gravity ventilating systems ser.vingconditioned space have Hither automatic or readily accessi le, manually operated dampers. 114: Pool and Spa Heating Systems and Eq ipment l• System is certified with 78% therma� efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot lig' 2. System installpd with: .a. At least 36 inches Pipe -between ilter and heater for future solar hFating. b.. Cover for outdoor pools or outdo r spa, 3. Pool system has directional inlets nd a circulation Pump time switch. 11S: Gas-fired central furnare, pool he.a_er., spa heater or household cooking appliance have no r_ co t.inuottsly burning Pil.olight (excPptron:.Non-electrical ooking appliance c with pilot < ISO Btuthr.). LIGHTING MEASURES . 1SOtc 40 Ind rooms or greater for general lighting in kitchens and rooms with water closets;land"recessed ceiling fixtures IC (inanlat.ion rover) approved. -. Z_ - Design= Enforce- er . ment COMPUTER METHOD SUMMARY. I`' Page I C -2R Project Title.......... STERLING HOMES Date........ 04/23/93 Project AddresS........ LA QUINTA LA QUINTA Ducumentation Author.,. ROCKY Building. Perm—Lt Company............... HERZBERGER/SALEHI ENG. Telephone.... (619) 239-4636 Plan Check Date Compliance Method...... MICROPAS4 by Eneromp, Inc.' 'Field Check/ Date' Climate Zone........ . 15 MICROPAS4 v4:01• File -G421 Wth-CZlSS92 Program -FORM C -2R. User#=M1'0406 User-HERZBERGER SALEHI ENG. Run -PLAN SW --1 Zone Type HOUSE Residence Conditioned Floor'Area..... Building Type .............. Construction Type.......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type....... ... Floor Construction Type.... Number of Building Zones... Conditioned Volume... .... Footprint Ar.ea............. Ground Floor Area........... Slab -On -Grade Area...... Glazing Percentage. ..... Average Ceiling Height..... BUILDING ZONE 1640 sf Single Family Detached New Front Facing 0 deg (N) 1 1 ReducedYear Slab On Grade (Package D) 1 16400 cf 1666 sf 1666 sf 1666 sf 25.8 % of FA 10 ft NFORMATION, Floor # of Area Volume Dwell (tond- Thermostat (sf) (cf) Units itioned Type 1640 16400 1.00 Yes Setback Vent Energy Use (kBtu/sf-yr) MICROPA84 ENERGY Stand Desi USE SUMMARY rd Proposed n Design 2 3.07 Compliance Margin -0.65 Space Heating........ . 2. n/a Space Cooling.......... 31. 9 31.34 -0.05 Water Heating..... .... 13. 9 12.02 1.37 Total 47.'0 46.43 0.67 *** Building. complies with Computer Performance *** GENERAL INFORMATION Zone Type HOUSE Residence Conditioned Floor'Area..... Building Type .............. Construction Type.......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type....... ... Floor Construction Type.... Number of Building Zones... Conditioned Volume... .... Footprint Ar.ea............. Ground Floor Area........... Slab -On -Grade Area...... Glazing Percentage. ..... Average Ceiling Height..... BUILDING ZONE 1640 sf Single Family Detached New Front Facing 0 deg (N) 1 1 ReducedYear Slab On Grade (Package D) 1 16400 cf 1666 sf 1666 sf 1666 sf 25.8 % of FA 10 ft NFORMATION, Floor # of Area Volume Dwell (tond- Thermostat (sf) (cf) Units itioned Type 1640 16400 1.00 Yes Setback Vent Special Height Vent Area (ft) (sf) 2.0 n/a COMPUTER METHOD SUMMARY Project Title.......,,: STERLING HOMES Page 2. C - 2 R. - Date........ 04/23193' MICROPAS4 v4.01" File -G421 Wth-C'Z15S92 Program -FORM C -2R User#7MP0406 User-HERZBERGERSALEHI ENG. Run -PLAN SW -1 PERIMETERjLOSSES Form 3 Reference Location/ Comments W.19.2X6.16 FRONT W.19.2X6.16 BACK W.19.2X6.16 RIGHT W.19.2X6.16 LEFT R.38.2X12.16 Attic Length F2 Iris 1 Surface (ft) Factor_ R-val Location/Comments HOUSE 6 S1abEdge .35 0.900 R-0 OUTSIDE 7 S1abEdge 114 0.720 R-0 To Outside 8 SlabEdge 20 0.500 R-0� To Outside FENESTRATIONiSURFACES SC SC Interior Area #'of Frame OpentJ7 Act Glass Int Shade Surface (sf) Panes Type Type value Azm Tilt Only Shade Description HOUSE 1 Window 45.0 2 OPAQUE SU I FACES 0 90 Area U- Insul Act Window 14.0 Solar Surface (sf) value R-val Azm Til 0.66 Gains HOUSE Window 48.0 2 Metal Slider x.,75 0 1 Wall 390 0.065 R-19 0 17.0 1 -Yes 2 wall 389 0.065 R-19 180 30 0 Yes 3 Wall 208 0.065 R-19 270 10 0.88 Yes 4 Wall 302 0.065 R-19 90 �U .75 Yes 5 Roof 1632 0:029 R-38 0 64.0, .0 Yes PERIMETERjLOSSES Form 3 Reference Location/ Comments W.19.2X6.16 FRONT W.19.2X6.16 BACK W.19.2X6.16 RIGHT W.19.2X6.16 LEFT R.38.2X12.16 Attic Length F2 Iris 1 Surface (ft) Factor_ R-val Location/Comments HOUSE 6 S1abEdge .35 0.900 R-0 OUTSIDE 7 S1abEdge 114 0.720 R-0 To Outside 8 SlabEdge 20 0.500 R-0� To Outside FENESTRATIONiSURFACES SC SC Interior Area #'of Frame OpentJ7 Act Glass Int Shade Surface (sf) Panes Type Type value Azm Tilt Only Shade Description HOUSE 1 Window 45.0 2 Metal Slider. 75 0 90 0.88 .0.66 Drapes.Std 2 Window 14.0 2 Metal , Slider .75 0 90 0.88 0.66 Drapes.Std 3 Window 48.0 2 Metal Slider x.,75 0 90 0.88 0.66 Drapes.Std 4 Window 17.0 1 Wood Hinged Q.92 180 90 1.00 0.46 Drapes.Wht 5 Window .4.0 2' None Fixed .56 180 90 0.88 0.65 None 6 Window 23.5. 2 Metal Slider .75 180 90 0:88 0.66 Drapes.Std 7, Window 64.0, 2 Metal Slider .75 180 90 0.88 0.66 Drape's.Std '8 Window 16.0 2 Metal Slider .75 270 90 0.88 0.66 Drapes.Std 9 Window 112..0 2 Metal Slider .75 270 90 0.88 0.66 Drapes.Std 10 Window 14.0 2 .Metal Sli.dp.r .75 270 90 0.88 0.66 Drapes.Std 11 Window 1.2..0 2 Metal Slider -75 �75 90 90 0.88 0.66 Drapes.Std 12 Window 36.0. 2 Metal Slider 90 90 0.88 0.66 Drapes.Std 13 Window 10.0 2 Metal Slider 6.75 90 90 0.88 0.66 Drapes.Std 14 Skylight 8.0 2 Metal Fixed 0.70 0 23 0.88 0.55 None Surface HOUSE .1 Window Window Window 4 Window 5 Window I OVERHANGS AND SIDE FINS Window ---Overhang- Left Fin, Right Fin --- Area' Left Rght (sf) Hght-.Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext- Dpth Hght 45.0 5 n/a 1 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 14.0 3.5 n/a 1 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 46.0 8 n/a 1 0.5 n/a n/a n/a n/a n/a n/a n/a -n/a 17.0 6.7 n/a 1 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 4.0 1 .n/a 1 0.5 n/a n/a n/a n/a n/a. n/a n/a n/a COMPUTER METHOD SUMMARY Project Title.......... STERLING HOMES Surface Page 3 C -2R Date........ 04/23/9'3 MICROPAS4 v4.01 File -6421 wth-CT 15S92 Program -FORM C -2R' User#-MP0406 User-HERZBERGER/�ALEHI ENG. Run -PLAN SW -1 6 Window 7 Window 8 Window 9 Window 10 Window 11 Window 12 Window 13 Window A .Mass Type OVERHANGS AND FIDE FINS HOUSE 1 S1abOndrade 2 S1abOnGrade 3 S1abOnGrade 4 S1abOnGrade 5 S1abOnGrade Window- SX A.DTNG Overha g - Shading Surface. 'ed. Type n/a HOUSE, n/a Left n/a Rght 45.0' (sf) Hght Wdth Dpth Hght Exp 3 Window Ext Ext S,cre'en. 6 Window 23.5 Sun Screen 7 Window 64.0 Sun. Screen 23.5 2.5 n/a 1 0.5 n/a Sun n/a- n/a 64.0 8 n/a 1 0.5 n/'a n/a n/a 16.0 2 n/a 1 0.5 n/a n/a' n/a 112.0'8 n/a 1 0.5 n/�a n/a n/a 14.0 3.5 n/a 1 0.5 n/a n/a n/a 12.0 2 n/a .1 0.5 n/p n/a n/a 36.0 6 n/a 1. 0:5 n/a n/a n/a 10.0 2 n/a 1 0.5 nAa n/a n/a HOUSE 1 S1abOndrade 2 S1abOnGrade 3 S1abOnGrade 4 S1abOnGrade 5 S1abOnGrade System Type HOUSE Furnace' ACSplit Left Fin Dpth Hght Ext n/a EXTERIOR SX A.DTNG n/a Area Shading Surface. (sf) Type n/a HOUSE, n/a n/a n/a 1 .window 45.0' Sun Screen 2 Window. 14.0 Sun . SFreen 3 Window 48.0 Sun: S,cre'en. 6 Window 23.5 Sun Screen 7 Window 64.0 Sun. Screen 9 Window 112.0 Sun Screen 10 Window 14.0 Sun Screen i TH E RMAL. IMAS S Area Thick Heat Conduc - Surface (sf) (in) -Cap ivityI �r R -value 1280 3.5 28.0 0.98• R-2.0 195 3.5 28.0 -0.98 R-0.0' 156 3..5 28.0 0.98 R-0.0 25 3.5 28.0 0.98. R-0.0 10 3.5 28.0 0-.98 R-0.0 System Type HOUSE Furnace' ACSplit Left Fin Dpth Hght Ext n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a SC of Ext Shade 0.34 0.34 0.34 0.34 0.34 0.34 0.34 Right Fin- Dpth Hght n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/e n/a n/a. Location/Comments s Covered KITCHEN/ NOOK BATH ENTRY/HALL HEARTH HVAC SYSTEMS Minimum Duct Duct Duct Efficiency_ ocation R -value Effici,ency 0.800 AFUE Attic R-4.2 0.830 12.00 SEER Attic R-4.2. 0.810 :OMPUTER METHOD SUMMARY ' Page 4 C-2R 'roject Title........... STERLING HOMES Date:....... 04/23/93- MICROPAS4'v4.01 File-G421 Wth-CT 15S92 Program-FORM C-2R • I User#-MP0406 User-HER2RSRGGSR/�ALEHI ENG.. Run-PLAN SW-1 WATER HEATINGISYSTEMS Number Tank External in Energy Size Insulation Tank Type Neater Type Distribution Type System Factor (gal) R-value 1 Storage. Gas" Standard -1 0.59 38 R-12 SPECIAL FEATUR S/REMARKS . r L.O. SMITH PGS=04.0 38.0 GALLON IHEEM RGDG-075AMGR 60500 BTU/HR 80.5% AFUE IHEEM RPMA-036JA 35600 BTU/H 12.0 SEER. I • I :ONSTRUCTION ASSEMBLY project Title. .......... STERLING HOMES I Date,... .. 04/23/9,3.. MICROPAS4 v4..01 :File --G421 Wth-CT 15592 Program -FORM 3R User$-MP0406 User-HERZBERGER/SALEHI ENG. Run -PLAN SW -1 Sketch of Construction Assembly .IST -OF CONSTRUCTION COMPONENTS .Referena Name W.19.2X6.16 Description .. wall R-19' 2x6 16oc Type ......,, Wall, R -Value ........ 19 af-F/Btuh Framing Material FIR.2X6 Spacing .... 16 inches on center Fraction ......0.15 Material Cavity- Frame Name Description R -Value R -Value U. FILM. EX Exterior air filen: wins r value 0.17 0.17 1. STUCCO.0.88 0.875 in stucco 0.17 0.17- 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3c..BATT.R19 R-19 batt insul (cavity 5.5 in) 17.80 �- 3f. FIR.2X6 2x6 in fir framing -- 5.45 4, GYPr0.50- 0.50 in gypsum.or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68. 0.68 Total U adjusted R -Values 19.34 6.98. `RAMING ADJUSTMENT CALCULATION Cavity Framing Total 1 -Value: '(`1 / 19-34 x 0.85) + (1 / 6.98*x 0.15) = 0.065 Btuh/sf-F Votal R -Value: l / 0.065• = 15.28 sf-F/Btuh CONSTRUCTION ASSEMBLY Page 2 3R Project Title.......... STERLING HOMES I Date. .. 04/23/93 MICROPAS4 v4.01 File -G421 Wth-CT lSS92 Program -FORM 3R User#-MP0406 User-HERZBERGER/ ALEHI ENG. Run -PLAN SW -1 Referen a Name R.38.2X12.16 Descrip ion Roof R-38 2x12 16oc Type .. . Roof R -Value ......... 38 sf-F/Btuh Framing Mater al ..... FIR.2X12. Spacing ...... 16 inches on center Fract. on . 0.10 axoLcn of Construction Assembly LIST OF.CONSTRUCTION COMPONENTS Material*Cavity Name Description R -Value RFValue �. 1. FILM.EX SHNGL.ASPHLT Exterior air film: winter value Asphault.shingle 0.17 0.17 2. 3. BLDG.PAPER PLY.0.50 roofin Building paper (felt) 0.44 0.06 0.44 0.06 4c.-AIR.RF.0.75` 4f. FIR.2X12 0.50 inYwood 1 P 0.75 in (approx) air sp'ce: heat flow up 0:62 0.75 0.62 - Sc. 6. BATT.R38.0 GYP 2x12 in fir framing R-38 batt insul (cavity > 11..25 in) _-,38 00 11..14 I. -0,50 FILM.IN.RF 0.50 in gypsum or plaster board Inside air film: heat f 0.45. 0.45 ow straight' -up 0.61 0.61 .-'Total.Un4djusted R -Values 41.10 .13.49 'RA -MING ADJUSTMENT CALCULATION Cavity Framing ,• Total -Value: (1 /. 4.1.10 x 0.90) + (1 / 13.4 x 0:10) 0.029 Btuh/sf-F otal R -Value: 1 ;( 0.029 = 34.12 sf-F/Btuh COMPUTER METHOD SUMMARY Project Title.......... STERLING HOMES Surface Page 3 C -2R Date........ 04/23/93 MICROPAS4 v4.01 File -6421 Wth-CT 15S92 Program -FORM C -2R-. User#-MP0406 User-HERZBERGER/�ALEHI ENG. Run -PLAN SW -1 6 Window 7 Window 8 Window 9 Window 10 Window 11 Window 12 Window 13 Window Surface HOUSE . 1 Window 2 Window 3 Window 6 Window 7 Window 9 Window 10 Window Area Mass Type (sf) HOUSE 1 SlabOnGrade 2 SlabOnGrade 3 SlabOnGrade 4 SlabOnGrade 5 S1abOnGrad6 Thick (in) 1280 3.5 195 3.5 156 3.5 25 3.5 10. 3.5 System Type HOUSE Furnace' ACSplit Area Shadibg OVERHANGS AND FIDE FINS Type Ext Shade 0.98 4.5.0 Sun SLCreen Window- 14,0 Sun Overha g 48.0Sun .. Left Fin ..0.34 Right Fin - Area 0.34 64.0 Sun Screen Left 112.0. Right Screen 0.34 14.0 Sun Screen' 0.34 (s f ) Hght Wdth Dpth Hght EExx� Ext Ext Dpth Hght Ext. Dpth Hight 23.5 2.5 n/a 1 0.5 n/a n/a n/a n/a n/a n/a n/a nfa 64.0 8 n/a 1 0.5 n/ n/a n/a n/a n/a n/a n/a, n!a 16.0 2 n/a 1 0..5 n/la n/a n/a n/a n/a n/a n/a n'a 112.0 8 n/a 1 0.5 n/6 n/a n/a n/a n/a n/a n/a n!a 14.0 3.5 n/a 1 0.5 n/� n/a n/a n/a n/a n/a n/a n!a 12.0 2 n/a` 0.5 1 n/p n/a n/a n/a n/a n/a n/a n!a 36.0 6- n/a 1 0.5 n/a n/a n/a n/a n/a n/a n/a n!a 10.0 2 n/a 1 0.5 n/ia , n/a n/a n/a n/a n/a n/a n!a EXTERIOR S)- ING Surface HOUSE . 1 Window 2 Window 3 Window 6 Window 7 Window 9 Window 10 Window Area Mass Type (sf) HOUSE 1 SlabOnGrade 2 SlabOnGrade 3 SlabOnGrade 4 SlabOnGrade 5 S1abOnGrad6 Thick (in) 1280 3.5 195 3.5 156 3.5 25 3.5 10. 3.5 System Type HOUSE Furnace' ACSplit Area Shadibg SC of (sf) Type Ext Shade 0.98 4.5.0 Sun SLCreen 0.34 14,0 Sun SFreen 0.34 48.0Sun ENTRY/HALL Screen ..0.34 23.5, ..Sun Screen 0.34 64.0 Sun Screen 0.34, 112.0. Sun Screen 0.34 14.0 Sun Screen' 0.34 TH E RMAL IMAS S Heat Conduc ,- Surface J Cap ivityl R -value Location/Comments 28.0 0.98 R-2.0 Covered 28.0 0.98 R-0:0. KITCHEN/ NOOK 28.0. 0.98 R-0.0 BATH 28 '.0 0.98 R-0.0 ENTRY/HALL 28.0 0.98 R-0.0 HEARTH HVAC SYSTEMS Minimum Duct Duct Duct Efficiency. Location R -value Efficiency 0.800.AFUE Attic 12.00 SEER Attic R-4..2 '0.830 R-4.2 0.810