13-0159 (RC)P.O. BOX 1504
CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: 13-00000159 Owner:
Property Address: 77935 CALLE TAMPICO STE 103 CORONEL ENTERPRISES INC
APN: 773-076-006- P,O BOX 389
Application description: REMODEL COMMERCIAL LA QUI,NTA, CA 92253
Property Zoning: VILLAGE COMMERCIAL
Application valuation: 10000
contractor:
Applicant: Architect or Engineer: CORONEL-ENTERPRISES
42760 MADIO STREET
INDIO, CA 92201
(760)775-1234
Lic. No.: 727199
- - - - - - - - - - - - - - - - - - - - m -- - - - - - - - - - — — — — — — — — — — — — — — — — — — — — -
CEN fD CONTRACTOR'S DECLARATION.
I hereby affirm under penalty of per� ry that I am,licensed under pr er 'cor" mencing with
ovisi�� orc and
Section 7000) of Division 3 of t siness and Professionals -5 Licens.L�i—s;n a effect.
License Class: B fu LicenseNo.: 727199
a actor:
*""*'D Ve�lt—U I '!�ntr 0
R
t' am ex p
Prof s 0
FR -BUILDER . DECLARATION
I hereby affirm under penalty of perjury t t I M ex pt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business d rof sions Code: Any city or county that requires a permit to
s
st,uctu
construct, alter, improve, demolish, or rep tructure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing With Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1, as owner of the property, or my�employees with wages as their.sole compensation, will do the work, and
the structure is not intended or offered for sale ISec. 7044, Business and Professions Code: 'The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own. employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Caw does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
I am exempt under Sec. B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGE NCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued fSec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX ( 760) 777-7011
INSPECTIONS (760Y 777-7153
Date: 4/10/13
APR 12013
CITY OF LA QUINTA
FINANCE DEPT
------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the. following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for he performance of the work for. which 'his permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier�STATE FUND Policy Number 9033452 —201'1-----
I certify th! t; in the perf2jpwrrl—cet� the work for which this permit is issued, I shall not ierp�ioy any
person in any ma 6r so as tojiecome subject to the workers' compensation laws of Cali nia,
and agree that, I should become subject to the workers' compensation provisions of Secti
s 1 0'
3700 of the Lab
d7all forthwith comply with those provisions.
Datw(— '70' �Appli
WARNING: FAILURE TO SECURE ' 0 IPENSATION COVERAGE IS UNLAWFUL, AND SHALL
J SAN
SUBJECT AN EMPLOYER Ti CRIM=% NALT VIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION T� THVOST OF COMPENSATION; DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, ikr5§EST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this appli becomes,null and void if work is not commenced
within 186 days from data f is :t a of such rmit, or cessation of work for 180 days will subject
permit to cancellation. ' su
-I certify' that I have read this application : state that the above. information is correct. I agree to comply with all -
city and county ordinances and state laws elating to building, constr6ction, and hereby authorize representatives
t
of this county to inter upon the above-minti o erty for inspection purposes.
Date:�-, — —_,signature (Applicant or Agent): -
0
4
Application.Number
13-00000159
------ Structure Information
1,453SF OFFICE TI/VB/B-OCC/15-OL/SPRINK -------
0ther struct'info . .
. . . CODE EDITION 2010
FIRE SPRINKLERS YES
MIXED-USE OCCUPANCY B
OCCUPANT LOAD
15.00
------------- ----------------------------
IST.FLOOR SQUARE FOOTAGE 1453.00,
--------------------------------
Permit . . . . . . .
BUILDING PERMIT
Additional desc
Permit Fee . . . .
117.00, 'Plan Check Fee
76.05
Issue.Date.
Valuation . . . .
10000
Expiration'Date
10/07/13
Qty Unit Charge
-Per
Extension
BASE FEE
45.0.0
8_0& 9.0000
- - - - - - - - - - - - - - - - - - - - - --- - - 7
THOU BLDG�2,001-25,000
--------------------- 7 -------------------------------
72.00
Permit . . . . . .
ELECT -'ADD/ALT/REM,
Additional desc
Permit Fee . . . .
�44.14 Plan'Check Fee
11.04
Issue Date . . . .
Valuation . . . .
0,
Expiration Date
10/07/13
Qty Unit Charge
Per
Extension
BASE FEE
.15;00
1457.00 ;0200
7 - - - - - - - - - - - - - --- - - - - 7
ELEC GARAGE OR NON-RESIDENTIAL
- - - - - - - - - - - - - - - - - - - 7 - - - - - - --- - - - - - - - - - - -
29.14
- - - - - - - - - -
Permit . . . . . .
MECHANICAL
Additional desc
Permit Fee . . .
32.50. Plan Check Fee,:
Issue Date . . . .
Valuation
0
Expiration Date
10/07/13.
_Qty Unit -Charge
Per
Extension
BASE FEE
15.00,
1.00 4.5000
EA MECH VENT INST/:DUCT'ALT
4.50
2.00 6.5000
---------------------------------
KA MECH VENT FAN-
-----------------------------------------
13.00
77 ---
Permit-
PLUMBING
Additional desc
Permit Fee . . . .
55.50 Plan Check Fee
13.88
Issue Date
Valuation . . . .
0
Expiration Date
10/07/1�3
LQPERMIT
Application Number 13-00000159'
Permit ... . . . . PLUMBING
Qty Unit Charge Per
Extension
BASE FEE
15.00
5.00 6.00,00 FKA PLB FIXTURE
30.00
.1-.00 7.5000 EA PLB WATER HEATER/VENT
7.50
3.0000 EA PLB,WATER INST/ALT/REP
3.00
--------------- ---------------------------
Special Notes and Comments..
1,453SF OFFICE TI/VB/B/15-OL/SPRINKLED
[CORONEL ENTERPRISES] -THIS PERMIT DOES
NOT INCLUDE ALTERATION TO THE BUILDING
SHELL,OR EXTERIOR SIGNAGE. 2'010
CALIFORNIA BUILDING CODES. -
April 10, 2013 4:51:56 PM AORTEGA
----------------------------------------------------------------------------
Other Fees . . . . . . ACCESSIBILITY PLAN'REVIEW
.7.61
BLDG STDS ADMINASB1473)
1.00
ENERGY REVIEW FEE
7.61
STRONG MOTION (SMI) - COM
2.10
Fee, summary Charged Paid Credited
- ; ---- ------- ---------- ---
Due
-------
---------- --------
Permit F6e'Total' 249.14 .00 .00
.249.14
Plan Check Total 109.10 .00 .00
109.10
Other,Fee Total .18.32 .00 .00
'18.3-2
Grand Total 376.56 .00 -.00
376.56
LQPERMIT
..
. ....... 2EM! .........................
..... ...... .
............. :.... . .:: - ::%.:.. - ....:
.......... .. : .... ::., ... ::: . -:-- - :. .: .:.: :.. ..
......... .. ........
... .... ..i Oi.i
pr
777777
..
. ....... 2EM! .........................
..... ...... .
............. :.... . .:: - ::%.:.. - ....:
.......... .. : .... ::., ... ::: . -:-- - :. .: .:.: :.. ..
......... .. ........
... .... ..i Oi.i
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Coronel Plaza - Unit 103—RUN #3
77935 Calle Tampico,#1 03
La Quinta, CA 92253
Project Designer:
Santiago Lopez-Ocampo Desig
79636 Newbury Terrace RECEIVED
Indio, CA 92203.
760-485-8927 MAR 2 0 2013
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
Report Prepared by:
Jack LaFontaine
Energy Management Services
41-485 Adams Street- Unit C
Bermuda Dunes, CA 92203-1186
760-360-4631
is A
CITY Or LA QUINTA
Job Number: BUILDING & SAFETY DEPT.
02012013a -,.1APPROVED
STRUCTION
FOR CON
Date:
C)ATE lwvqj—� By —(Z
3/19/2013
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
TABLE OF CONTENTS.
Cover Page
Table of Contents 2
'Form LTG -1-C Certificate of Compliance 3
,Form LTG -2-C Lighting Controls Credit Worksheet 7
Form LTG -3-C Indoor Lighting Power Allowance 8
-Form LTG -4-C Tailored Method Worksheet 9
Form LfG-MM Lighting Mandatory Measures -10
CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1 C
Project Name
Date
Coronel Plaza - Unit 103 RUN #3
311912013
Project Address
Zone
Total Cond. Floor Area
Unconditioned Floor Area
77935 Calle Tampico #103 La Quinta
15
1,457
0
GENERAL INFORMATION
Building Type: 10 Nonresidential 0 High -Rise Residential 0 Hotel/Motel Guest Room
[3 School [3 Relocatable Public 0 Conditioned Spaces 0 Unconditioned Spaces
School
Phase of Construction: 13 New Construction 13 Addition 10 Alteration
Method of Compliance: 0 Complete Building 0 Area Category El Tailored
Documentation Author's Declaration Statement
I certify that this Certificate of Compliance documentation is accurate and complete.
Sig (aturlea
Name
Jack LaFontaine
Company
D e
Energy Management Services
311912013
Address
CEA #x— 6 8— 0
41-485 Adams Street - Unit C
CEPE #
City/State/Zip
Phone
Bermuda Dunes, CA 92203-1186
760-360-4631
The Principal Lighting Designer's Declaration Statement
0 1 am eligible under Division 3 of the California Business and Professional Code to accept responsibility for the
lighting design.
0 This Certificate of Compliance identifies the lighting features and performance specifications required for
compliance with Title 24, Pages 1 and 6 of the California Code of Regulations.
0 The design features represented on this Certificate of Compliance are consistent with the information provided
to document this design on the other applicable compliance forms, worksheets, calculations, plans and
specifications submitted to the enforcement agency for approval with this building permit application.
Name
�F�ture
Santiago Loperz-Ocampo
Company
Phone
Santiago Lopez-Ocampo Design
760-485-8927
Address
License #
79636 Newbury Terrace
City/State/Zip
Date
Indio, CA 92203
Lighting Mandatory Measures
Indicate location on building plans of Mandatory Measures Note Block:
LIGHTING COMPLIANCE FORMS & WORKSHEETS (check box if worksheets is included)
For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms; please refer to the Nonresidential Manual published
by the California Energy Commission.
LTG -1C Pages 1 through 4 Certificate of Compliance. All Pages required on plans for all submittals.
LTG -2C Lighting Controls Credit Worksheet
E] LTG -3C Indoor Lighting Power Allowance
[Z) LTG -4C Pages 1 through 4 Tailored Method Worksheet
[3 LTG -5C Pages 1 and 2 Line Voltage Track Lighting Worksheet
EnergyPro 5. 1 by EnergySoft User Number: 5021 RunCode: 2013-03-19TO9:27:09 ID:02012013a Page 3 of 10
CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG -1 C
Project Name
Coronel Plaza - Unit 103—RUN #3
Date
311912013
INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST
Installation Certificate, LTG -1 - INST (Retain a coliy and verify form is completed and signed.)
'�Field Inspector 0
Certificate of Acceptance, �TG-2A and LTG -3A (Retain a copy and verify form is completed a d signed.)
F1 eld Inspector 0
A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces Installed Lighting Power listed on
this Lighting Schedule is only for:
0 CONDITIONED SPACE 11' UNCONDITIONED SPACE
0 The actual indoor lighting power listed below includes all installed permanent and portable lighting systems in accordance
!with §1 46(a).
Only for offices: Up to the first 0.2 watts per square foot of portable lighting shall not be required to be included in the
0 calculation of actual indoor lighting power density in accordance with the Exception to §1 46(a). All portable lighting in excess of
0.2 watts per square foot is totaled below.
Luminaire (Type, Lamps, Ballasts)
Installed Watts
A
B
C
D
E
F
G
-H
None
or
Item
Tag
Complete Luminaire Descriptio�'
(Le, 3 lamp fluorescent troffer,
F32T8, one dimmable electronic ballasts).
(D
(D .�=
CL co
S
E
D
—J
How wattage
Was determined
Z 0
4)
6 "Co
-0
E E
:3 :3
Z -J
LL
X
-0
S
Field
inspector2
6
-0
CM
.
CEC :p �2
Default 0 W)
From 0 0
NA8 <
_LL-
48'�2 tube
(2) 4 It Fluorescent T8 ElecRO
48.0
11
3
144
'-E] 0
48'�3 tube
(3) 4 ft Fluorescent T8 ElecRO
70.0
20
1,400
11 1:1
0- 0'
1-1 0
0 0
11 0
0 0
0 0
0 0-
0 0
0— 0.
0 0
0 0
1:1
El 0
0 11
'0 0
0 0
1:1 11
11 0
0 0
0 0
0 0.
1:1 0
0
0' 0
0 01
0 0
0 0
0 0
0 0
El [3
Installed Watts Page Total:
1,5441
Building total number of pages:
Installed Watts Building Total
(Sum of all pages)
1,544
Enter into LTG -1 C Page 4 of 41
1. Wattage shall be determined according to Section 130 (d and e). Wattage shall be rating of light fixture, not rating of bulb.
2. If Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary.
EnergyPro 5. 1 by EnergySoft User Number: 5021 RunCode: 2013-03-19TO9:27.-09 ID:02012013a
CERTIFICATE OF COMPLIANCE (Part 3 of 4)
LTG -1 C
Project Name
Coronel Plaz'a - Unit 103—RUN #3
Date
311912013
INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST
Fill in controls for all spaces: a) area controls, b) multi-level controls, c) manual claylighting controls for daylit areas > 250 ft2,
automatic daylighting controls for daylit areas > 2,500 ft2, d) shut-off controls, e) display lighting controls, f) -tailored lighting controls —
general lighting controlled separately from display, ornamental and display case lighting and g) demand responsive automatic
2
controls for retail stores > 50,000 It ; in accordance with Section 131.
MANDATORY LIGHTING CONTROLS — FIELD INSPECTION ENERGY CHECKLIST
Field
Inspector
Number Special
Type/ Description of Units Location in Building Features
Pass
Fail.
11
0
0
0
0
0
0
'0
0
d
0
0
0,
0
0
la
z
0
0
0
0
0
0
0
0
0
0
0
0
0
13
0
0
0-
0
o,
(i
0
0
0
0
0"
0
0
0
0.
0
0
11
0
.0
0
0
-0
0.1
0
0
0
11
0
1
Pro
0
0
-
SPECIAL FEATURES INSPECTION CHECKLIST (See Page 2 of 4 of LTG -1C)
The local enforcement agency should pay special attention to the. items specified in this checklist. These items'require special written
justification and documentation, and special verification. The local enforcement agency determines the adequacy of the justification,
and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation
submitted.
Field Inspector's Notes or Discrepancies:
rE—,e,gyP,o 5.1 by EegySoft Use, Number 5021 RunCode: 2013-03-19TO9:27:09 ID:02012013a
Pa;7e R-101
CERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG -1C
Project Name
Date
Coronel Plaza - Unit 103 RUN #3 1
311912013
CONDITIONEb AND UNCONDITIONED SPACE LIGHTING MUST
NOT BE COMBINED FOR COMPLIANCE
Indoor Lighting Power for Conditioned S aces
Indogr Lighting Power for Uncondition d Spaces
Wafts
Watts
Installed Lighting
1,544
Installed Lighting
0
(from Conditioned LTG -1C, Page 2)
(from Unconditioned LTG -1C, Page 2)
Lighting Control Credit
Lighting Control Credit
0
Conditioned Spaces (from LTG -2C)
Unconditioned Spaces (from LTG -2C)
Adjusted Installed
1,235
Adjusted Installed
0
Lighting Power
Lighting Power
Complies if Installed:5 Allowed
Complies if Installed:5 Allowed
Allowed Lighting Power
Allowed Lighting Power
Conditioned Spaces (from LTG -3C or PERF -1
1, 238
Unconditioned Spaces (from LTG -3C)
0
Required Acceptance Tests
Designer:
This form is to be used by the designer and attached to the plans. Listed below is the acceptance test for the Lighting system,
LTG -2A and LTG -3A. The designer is required to check the acceptance tests and list all control devices serving the building or space
shall be certified as meeting the Acceptance Requirements for Code Compliance. If all the lighting system or control of a certain type
requires a test, list the different lighting and the number of systems. The NA7 Section in the Appendix of the Nonresidential
Reference Appendices Manual describes the test. Since this form will be part of the plans, completion of this section will allow the
responsible party to budget for the scope of work appropriately. Forms can be grouped by type of Luminalre controlled.
Enforcement Agency:
Systems Acceptance. Before Occupancy Permit is granted for a newly constructed building or space or when ever new lighting
system with controls is installed in the building or space shall be certified as meeting the Acceptance Requirements.
The LTG -2A and LTG -3A forms are not considered complete forms and are not to be accepted by the enforcement agency unless
the boxes are checked and/or filled and signed. In addition, a Certificate of Acceptance forms shall be submitted to the enforcement
agency that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements
of §10-103(b) of Title 24 Part 6. The field inspector must receive the properly filled out and signed forms before the building can
receive final occupancy. A copy of the LTG -2A and LTG -3A for each different lighting luminaire control(s) must be provided to the
owner of the building for their records.
LTG -2A and
Luminaires Controlled
LTG -3A
Controls and
Sensors and
Number of
Automatic
Luminaires
Daylighting Controls
Equipment Requiring Testing
Description
controlled
Location
Acceptance
Occ Sensor - Multi -Level
(3) 4 ft Fluorescent T8 ElecRO
20
Complete Building Office
0
Occ Sensor - Multi -Level
(2) 4 ft Fluorescent T8 ElecRO
3
Complete Building Office
0
0
—
0
0
0
0
0
0
0
0
13
EnefgyPro 5. 1 by EnergySoh User Number: 5021 RunCode: 2013-03-19TO9:27:09 ID:02012013a Page 6 of ID
LIGHTING CONTROLS CREDIT WORKSHEET (Part 1 of 2) LTG -2C
Project Name
Coronel Plaza - Unit 103—RUN #3
Date
� 311912013
POWER ADJUSTMENT FACTORS (PAF) FOR NON -DAYLIGHT CONTROLS
A Separate PAF Worksheet Must Be Filled Out for Conditioned and Unconditioned Spaces. Control Credits listed on this
schedule are only for:
[0 - CONDITIONED SPACES 0 UNCONDITIONED SPACES
A B C D E F
G
Watts of Power
Room # Zone ID Plan Room Area Control Adjustments
Areas Lighting Control Description' Reference (ft) Lighting Factor'—
Control
Credit Watts
(E x F)
Complete Building � Occ Sensor - Multi -Level 48"13 tube 1,457 1,400 0.20
280
Complete Building( Occ Sensor - Multi -Level 48'�2 tube 1,4571 144 0.20
29
PAGE TOTAL
309
Note:
Building total of non -daylight control credit watts for all pages of LTG -2C Page 1 of 2
Conditioned and
Unconditioned
Enter building total of all daylight cont ols credit watts from LTG -2C Page 2 of 2
I
0
Space shall be
separately
totaled
BUILDING TOTAL OF ALL CONTROL CREDIT WATTS
(FOR BOTH NON -DAYLIGHT AND DAYLIGHT CONTROL CREDITS)
Enter in LTG -1 C; Page 4: Lighting Control Credit as appropriate for CONDITIONED
or UNCONDITIONED Spaces
309
I
1. Description shall be consistent with Type of Control defined in Table 146-C
2. Power Adjustment Factor taken from Table 146-C
.EnergyPro5.1byEnergySoft UserNumber5021 RunCode: 2013-03-19TO9:27:09 ID:02012013a Page 7 of 10
INDOOR LIGHTING POWER ALLOWANCE LTG -3C
Project Name
Corionel Plaza - Unit 103—RUN #3
Date
311912013
ALLOWED LIGHTING POWER (Chose One Method)
A Separate LTG -3C must be filled out for Conditioned and Unconditioned Spaces. Indoor Lighting Power Allowances listed on this
page are only for:
[a CONDITIONED SPACES 13 UNCONDITIONED SPACES
COMPLETE BUILDING METHOD
WATTS
BUILDING CATEGORY (From §146 Table 146-E) PER (ft)
X
COMPLETE
BLDG.AREA
ALLOWED
WATTS
Comp Bldg 0 0.85
1,457
1,238
TOTALS
AREA
WATTS
AREA CATEGORY METHOD
WATTS
BUILDING CATEGORY (From §146 Table 146-F) PER (ft)
x
Area ft2
ALLOWED
WATTS
TOTALS
AREA
WATTS
TAILORED METHOD
Total Allowed Watts using the Tailored Method taken from LTG -4C (Page 1 of 4
The indoor ligh ing power allowance using the Tailored Method of compliance shall be determined using the LTG -4C set of forms. A separate set of LTG -
4C forms shall be filled out for CONDITIONED and UNCONDITIONED spaces
EnergyPro 5. 1 by EnergySoft User Number: 5021 RunCode: 2013-03-19TO9:27:09 ID:02012013a Page 8 of 10
TAILORED METHOD WORKSHEET
(Part 1 of 4)
LTG -4-C
Project Name
Coronel Plaza - Unit 103—RUN #3
Date
1 311912013
TAILORED METHOD SUMMARY – Separate Tailored Method Worksheets shall be filled out for Conditioned and
Unconditioned Spaces:
0 CONDITIONED SPACES 0 UNCONDITIONED SPACES
1. Allowed Watts for Illuminance Categories (Building Total from Column G from Tailored General Lighting
Power Table below)
291
Watts —
2. Wafts for Display Lighting
01 1 01 1
Wall Display from Floor Display Ornamental/Special
LTG -4C + From LTG -4C + Effects Display from
Page 2 of 4 Page 2 of 4 LTG -4C Page 3 of 4
01 1 01
Very Valuable
+ Merchandise
LTG -4C Page 3 of 4
F Z
Total Watts
3. Total Allowed Watts (add lines I and 2)
291
Wafts
TAILORED ALLOWED GENERAL LIGHTING POWER
A
B
C
D
E
F
G
Room
Primary Function Type'
Illuminance
Cateqory2
Room
Cavit
Ratio x
RCR from
LTG -4C
Page 4 of
4?
Floor
Ar a for
Primary
Function 4
Allowed
LPD 5
Allowed
Watts
(E X F)
Y N
—Number
A
0.00
0 0
1,457
0.20 291
13 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
ft2
TAG
OTAEL 1,457
BUILDING TOAL 1,457
Wafts
1
1 . From Table 146-G, Column 1
2. From Table 146-G, Column 2 or IESNA Handbook
3. If Column D checked 'N' then enter <3.5 in this column
4. Floor area must be for Primary Function type listed in Table 146-G Column 1. Floor area using the Area Category Method shall not be included
15. In accordance with Table 146-1
EnerqvPro5.1bvEnerqvSoA UserNumber5021 RunCode: 2013-03-19T09:27.-09 ID:02012013a
Page 9 of 10
LIGHTING MANDATORY MEASURES: NONRESIDENTIAL LTG -MM
Project Name
Date
Coronel Plaza - Unit 103—RUN #3
311912013
Indoor Lighting
Measures:
§131(d): Shut-off Controls
For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting.
1 .
This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time
switch, or other device capable of automatically shutting off the lighting.
2.
Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible
override switch in sight of the lights. The area of override is not to exceed 5,000 square feet.
§1 19(h):
Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall
be certified and installed as directed by the manufacturer.
§111:
Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the
Directory. All installed fixtures shall be certified.
§ 131 (a):
Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy
sensor device for each area with floor -to -ceiling walls.
Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts
§131 (b):
per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the
room.
Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for
§ 131 (c):
the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch;
or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on
the adjacent lot. Diagram of shading during different times of the year is included on plans.
§131 (c):
Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less.6.
Outdoor Lighting Measures:
§130(c)l:
Mandatory lighting power determination for medium base sockets without permanently installed ballasts
§132(a):
All*permanently installed luminaires with lamps rated over 100 Wafts either have a lamp eff icacy of at least 60 lumens
per Watt or are controlled by a motion sensor.
§1 32(b):
All Luminaires with lamps rated greater than 175 Watts in hardscape area, including parking lots, building entrances,
canopies, and all outdoor sales areas meet the Cutoff Requirements.
§1 32(c)1:
All permanently installed outdoor lighting meets the control requirements listed.
§1 32(c):
Building facades, parking lots, garages, canopies, and outdoor sales areas meet the Multi -Level Lighting Requirements
listed.
EnergyPro 5.1 by EnergySoft User Number: 5021 RunCode: 2013-03-19TO9:27:09 ID:02012013a Page 10 of 10