BCOM2015-0015LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 892820•
Date: - 2 Contractor:
OWNER -BUILDER DECLARATION '
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, ttie building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon; and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's Address:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number:
_ I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date:Applicant:
WARNING: FAILURE TO SECURE WORKE S' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit,, or cessation of .
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city toter upon the above•
mentioned property for inspection purposes. � //
Date: s —U—f) Signature (Applicant or Agent)
f4�M�l/
VOICE (760) 777-7125
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253.
FAX (760) 777-7011
COMMUNITY DEVELOPMENT DEPARTMENT
INSPECTIONS
(760) 777-7153
BUILDING PERMIT
Application Number: . BCOM2015-0015 ,
Owner:
8
Property Address: 78134 CALLE TAMPICO STE 160
LA QUINTA REALTY PROP.
APN: 770020035
50415 VIA PUENTE
Z
Application Description: OLD TOWN ARTISAN STUDIO T.I.
LA QUINTA, CA 92253
C
Property Zoning:
Application Valuation: $60,000.00
0
r-+
Applicant:
Cont actor:
y C
BRIAN FITZGERALD
D'OROS CONSTRUCTION
54900 SOUTHERN HILLS
LA QUINTA, CA 92253
21 225 SMITH ROAD
SKY VALLEY, CA 92241
(760)329-4810
Llc. No.: 892820
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 892820•
Date: - 2 Contractor:
OWNER -BUILDER DECLARATION '
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, ttie building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon; and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's Address:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number:
_ I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date:Applicant:
WARNING: FAILURE TO SECURE WORKE S' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit,, or cessation of .
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city toter upon the above•
mentioned property for inspection purposes. � //
Date: s —U—f) Signature (Applicant or Agent)
FINANCIAL / {
,'DESCRIPTIONACCOUNT QTY, "AMOUNT �' PAID' PAID DATE
BSAS SB1473 FEE 101-0000-20306 ' 0 $3.00 $0.00
:PAID BY .; ,,, ;, METHOD::.RECEIP.T # ' CHECK # . ' CLTD�BY '
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $3.00 $0.00
.DESCRIPTION
' ACCOUNT , s xj ":"
QTY._
AMOUNT.
PAID
PAID. DATE
APPLIANCES, NON-RES
101-0000-42403
0
$96.68
$0.00
PAID BY', -
METHOD" -
_'RECEIPT # '
CHECK#,
CLTD BY',
,.DESCRIPTION'.
ACCOUNT ,�;QTY"
"' AMOUNT:,
PAID
PAID DATE
'DEVICES, ADDITIONAL
101-0000-42403
0
$24.20
$0.00
' -PAID BY -
METHOD
i. '. RECEIPT #
CHECK #
'CLTD BY
F.�
ACCOUNT
QTY
fPAID,.DESCRIPTION
PAID DATE
DEVICES, FIRST 20
101-0000-42403
0
$24.17
$0.00
PAID BY, 4
:r 'METHOD
;RECEIPT # `'
CHECK #
CLTD BY
Total Paid for ELECTRICAL: .$145.05 $0.00
DESCRIPTION =
ACCOUNT,., _
QTY.
AMOUNT ;t
'PAID.
PAID DATE,
OTHER MECHANICAL EQUIPMENT
101-0000-42402
0
$72.52
$0.00
PAID BY ,..
METHOD
`.'RECEIP.T# , .' , s
4 :'<CHECK•# . '
CLTD. BY
a DESCRIPTION _ -
'.r -" 'ACCOUNT
QTY
=' '- AMOUNT ,.
PAID, •
PAID DATE
VENT FAN
101-0000-42402
0
$24.18
$0.00
PAID BY «
m�'. METHOD,t
";RECEIPT #
",' CHECK # ' "'
CLTD BY.
}
Total Paid for MECHANICAL: $96.70 $0.00
DESCRIPTION '•
`.: -`i ACCOUNT ';" ' '
CITY.
„r;: AMOUNT ;
,PAID { -`
PAID DATE
BUILDING SEWER.
101-0000-42401
0
$12.09
$0.00
PAID BY =
.'METHOD
` RECEIPT #
CHECK #:
CLTD BY
' DESCRIPTION ;'>_ .
ACCOUNT y'
QTY
,„ AMOUNT;. °
r y, PAID'
PAID DATE
FIXTURE/TRAP
101-0000-42401
0
$72.54
$0.00
PAID BY
METHOD
•RECEIPT# - `'
'CHECK #
CLTD BY
DESCRIPTION - , .
ACCOUNT
QTY
AMOUNT r'
,,.
PAID r:<:
PAID DATE
WATER HEATER/VENT
101-0000-42401
0
$12.09
$0.00
u i ..:PAID BY : -
s
r
METHOD "` "
'. RECEIPT#::.`.
CHECK #'
CLTD BY.:.
DESCRIPTION"`
v. ACCOUNT s_ "''
C!TY'
"AMOUNT `
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$12.09
$0.00
#; PAID BY,
t METHOD �-
,. ..
RECEIP,T#
J' CHECK #
CL TD BY
Total Paid for PLUMBING FEES: $108.81 $0.00
DESCRIPTION xj
"'ACCOUNT
QTY
AMOUNT
_. "
PAID * '
PAID DATE.
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400
0
$108.75
$0.00
PAID BY.
METHOD N ,." y/
t R
RE # . _
CHECK #
CLTD BY,,',,
DESCRIPTION F': ='
" ACCOUNT r'
`r QTY ;
AMOUNT`
PAID r
PAID. DATE
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$87.00
$0.00
':PAID BY _=r
"METHOD . ;,
' i i RECEIPT:# !
,CHECK'.# .
-CLTD BY;
DESCRIPTION; : J ,
•. ' , ACCOUNT ' '
QTY
' AMOUNT `
N ,..` , PAID : r
,PAID DATE
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$0.00
PAID BY,
"METHOD'"'
,; 7 '.RECEIPT #
CHECK #
CLTD BY
^-DESCRIPTION
a. ACCOUNT 'n } .,,.,'_QTY
AMOUNT:'
F ;�. PAID k.
PAID,DATE
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$134.88
$0.00
"
PAID BY
` . `;METHODS
-` RECEIPT # *°
°''• ` CHECK # r ,
'CLTD BY °
Total Paid for REMODEL: $379.94 $0.00
TOTALS:• $0.00
Description: OLD TOWN ARTISAN STUDIO T.I.
Type: BUILDING, COMMERCIAL Subtype: REMODEL Status: APPROVED -CONDITIONS
Applied: 3/31/2015 PJU
Approved:
Parcel No: 770020035 Site Address: 78134 CALLE TAMPICO STE 160 LA QUINTACA 92253
Subdivision: PM 35845 Block: Lot: 1
Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $60,000.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
�HkONOLOGY� TYPE
Details: TENANT IMPROVEMENT FOR "OLD TOWN ARTISAN STUDIO" SUITE 160.2480SF FT. "B" OCCUPANCY. 45 OCCUPANT LOAD. INCLUDES
4 ELECTRIC. POWERED KILNS.2013 CODES
Printed: Thursday, May 21, 2015 9:44:51 AM I of 4
CV`?w-1YSTE;4S
ADDITIONAL SITES
CHRONOLOGY
�HkONOLOGY� TYPE
ACTION DXTE -
COMPLETION DATE
T';
."STAFF,NAME'
FOLLOW UP ON PLANNING REVIEW.
SPOKE WITH BRIAN FITZGERALD (APPLICANT) TO NOTIFY
NOTE
BURT HANADA
4/20/2015
5/7/2015
HIME THAT PLANS ARE APPROVED. A CONTRACTOR WITH
CITY BUSINESS LICENSE AND FIRE DEPT APPROVAL.IS
REQUIRED PRIOR TO PERMIT ISSUANCE.
COULD NOT FIND FOLDER BUT PUT PLANS WITH
NOTE
MARY FASANO
5/5/2015
5/5/2015
ATTACHMENTS IN BIN 3B
PLAN CHECK PICKED UP
PHILIP JUAREZ
4/20/2015
4/20/2015
PLANS PICKED UP BY ISREAL CHAVEZ 760-902-1932.
PLAN CHECK SENT TO
YOUNG ENGINEERING
3/31/2015
3/31/2015
OUTSIDE PC
PLAN CHECK SUBMITTAL
MARY FASANO
5/5/2015
5/5/2015
RECEIVED
Printed: Thursday, May 21, 2015 9:44:51 AM I of 4
CV`?w-1YSTE;4S
4 PLAN CHECK SUBMITTAL
PHILIP.JUAREZ
3/31/2015
PAID DATE RECEIPT # CHECK # METHOD ' "PAID BY CBYD
3/31/2015
INFORMATION
PAID
BSAS SB1473 FEE
NO STRUCTURAL INVOLVED PER APPLICANT.
RECEIVED
$0.00
-
Total Paid forBUILDING STANDARDS ADMINISTRATION
.BSA:
$3.00 .
$0.00 y
APPLIANCES, NON -RES
101-0000-42403
0
. TELEPHONE CALL
BURT HANADA
4/20/2015
4/20/2015
LEFT VOICEMAIL FOR. BRIAN FITZGERALD THAT CORRECTION
DEVICES, ADDITIONAL
101-0000-42403
0
$24.20
$0.00
LIST & PLANS ARE.READY FOR PICK UP.
DEVICES, FIRST 20
CONDITIONS
0
$24.17.
$0.00
CONDITION. ,
DATE DATE
'CONTACT DATE ADDED '•` - STATUS
REMARKS ; M NOTES
TYPE •
REQUIRED SATISFIED
Total Paid for ELECTRICAL:
$145.05
*. t
CONTRACTOR & FIRE APPROVAL REQUIRED
READY TO ISSUE
BURT HANADA 5/7/2015
IN PROCESS
PRIOR TO PERMIT ISSUANCE.
CONTACTS
NAME TYPE
, , �' _..NAME :;`
ADDRESS1
,• CITY
STATE
-ZIP
'PHONE
FAX
'EMAIL,_ :4
APPLICANT
BRIAN FITZGERALD
54900 SOUTHERN HILLS
LA QUINTA
CA
92253
(760)777-1440
CONTRACTOR
D'OROS CONSTRUCTION
21225 SMITH ROAD
SKY VALLEY
CA
92241
(760)777-1440
DESIGNER
AA DESIGN
81692 RANCHO -
LA QUINTA •
CA
92253
(760)777-1440
SANTANA DRIVE
OWNER
LA QUINTA.REALTY PROP. LLC
50415 VIA PUENTE
LA QUINTA
CA
92253
(760)777-1440
TENANT
OLD TOWN ARTISAN STUDIO INC
51105 AVENIDA VILLA
LA QUINTA
CA
92253
(760)777-1440
101
-
...
Printed: Thursday, May 21, 2015 9,44:51 AM _ _ 2 Qf 4 - C SYSTEMS
PAID DATE RECEIPT # CHECK # METHOD ' "PAID BY CBYD
FINANCIAL
DESCRIPTION ACCOUNT •-y ,' .QTY -,.AMOUNT
INFORMATION
PAID
BSAS SB1473 FEE
101-0000-20306 0
$3.00
$0.00
-
Total Paid forBUILDING STANDARDS ADMINISTRATION
.BSA:
$3.00 .
$0.00 y
APPLIANCES, NON -RES
101-0000-42403
0
$96.68
$0.00
DEVICES, ADDITIONAL
101-0000-42403
0
$24.20
$0.00
DEVICES, FIRST 20
101-0000-42403
0
$24.17.
$0.00
Total Paid for ELECTRICAL:
$145.05
$0.00
Printed: Thursday, May 21, 2015 9,44:51 AM _ _ 2 Qf 4 - C SYSTEMS
DESCRIPTION.'
�, ACCOUNT � -;
QTY
°AMOUNT
.:i.
PAID
' PAID DATE.
RECEIPT #
CHECK #.
METHOD
PAID BY
OTHER MECHANICAL
101-0000-42402
0
$72.52
$0.00
EQUIPMENT
VENT FAN
101-0000-42402
0
$24.18
$0.00
Total Paid forMECHANICAL: $96.70 $0.00 ;
BUILDING SEWER
101-0000-42401
0
$12.09
$0.00
FIXTURE/TRAP
101-0000-42401_
0
$72.54
WATER HEATER/VENT
101-0000-42401
0.
$12.09
$0.00
WATER SYSTEM
101-0000-42401
0
1$12.09
$0.00'
INST/ALT/REP
Total Paid for PLUMBING FEES: $108.81 $0.00 -
REMODEL'; EA
101-0000-42400
0
$108.75
$0.00-
l
ADDITIONAL 500 SF
REMODEL, EA
101-0000 42600
0
$87.00
_ . $0.00
ADDITIONAL 500 SF PC
REMODEL, FIRST 100 Sr
101-0000-42400
0
$49.31
$0.00
REMODEL, FIRST 500 SF
101-0000-42600
0 =
$134.88
$0.00
PC
Total Paid for REMODEL: $379.94 $0.00
TOTALS: $733.50 $0.00
INSPECTIONS
PARENT PROJECTS
Printed: Thursday, May 21, 2015 9:44:51 AM 3 Qf 4
YSTEMS
LISA
A `, ED
ttachment-T ` e CREAT r
_. • .
^ OWNER DESCRIPTION
READY FOR APPROVAL
Yp. t,�
=«
FIRE
NO_TTINGHA :
4/17/2015'
4/24/2015.
5/15/2015
_CONDITION
78-134 CALLE TAMPICO
M
4/20/2015
BURT HANADA
STE. 160 T.I..docx
STE. 160 T.L.docx
PLANNING
WALLY NESBIT
4/17/2015
4/24/2015
4/22/2015
READY FOR APPROVAL
LACI -15 -TI -018 BLDNG
-
NON -STRUCTURAL
BURT
5/5/2015.
5/12/2015
5/7/2015
APPROVED -
TI OLD TOWN ARTISAN
fire approval required prior to permit issuance.
0
HANADA
CONDITIONS
-
..
BOND INFORMATION
A `, ED
ttachment-T ` e CREAT r
_. • .
^ OWNER DESCRIPTION
: r
PATHNAME = _� SUBDIR ETRAKIT ENABLED t
Yp. t,�
=«
78-134 CALLE TAMPICO
78-134 CALLE TAMPICO
DOC
4/20/2015
BURT HANADA
STE. 160 T.I..docx
STE. 160 T.L.docx
1
LAQ-15-TI-018 BLDNG
LACI -15 -TI -018 BLDNG
DOC
5/15/2015
LISA NOTTINGHAM -
TI O -LD TOWN ARTISAN
TI OLD TOWN ARTISAN
0
STUDIO.docx -
STUDIO.docx -
Bin #
C'5
.
Permit V O(y
I d,
Project Address:7
City of La Q rain to .
.-Building 81: Safety Division
P.O. Box 1504, .78-4.95 Calle Tampico .
,
La Quinta, CA 92253 - (760) 777-7012.
Building Permit Application and Tracking-Sheet
Owners Name: '
�'� , Tt���l,R-�
A. P. Number:
Address: ���'/ 3 L/. � ` T P' Co.
Legal Description:. `
City, ST, Zip: L j C. 4'1
Contractor:
Telephone: Z —
P
Address:: 1 u D J �` ` , ��� S
Project Description:
City; ST, Zip: iW
Telephone:'
J
`>
v n c dkRi r
Stale Lie. # `.�, �• ^
—City Lic- #;:�`��
Arch., Engr., Designer:
Address:
City.,,ST, Zip:
Te tionc: ' _
P
.�<?<"�<��"�s<:.<."><
�`::��:,•.,j`';'.. �:.jvi�:T>�:ii':,'. :i �:iti?ti �:!::i>:i:i Si��:
�c . ecu an cy •
Coristrucfion T e. _ �✓'� .-.� r iir�` P �'• -
State Lic. #:
Project type (circle onc):/-New Add'n Alter Repair Demo
Name of Contact. Person:
' �� r j����,,`
Sq. Ft.:
# Stories:
#Units:
Telephone #,of Contact Person
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE ., .
l/ Submittal
Rcq'd.
Rcc'd
TRACKING
T.
PERMIT FEES
Plan Sets
Plan Check submitted
J
Item
Amount
Structural Cates.
Reviewed, ready for corrections
Plan Check Deposit
Truss Cales.
Called Contact Person
Plan Check I3alanee
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubtditted
�,
.. Mechanical
Grading plan
2"" Review, ready for corrections/issue..
Electrical
Subeontaetor List
Called Contact Person
Plumbing
Grant Decd
Plans picked up ,
r a. ,
S.M.I.
Ii.O.A. Approval
Plans resubmitted
Grading
IN IiOUSE:-
'`d Revicw, ready for corrcctions/issuc
Developer Impact Fee.
Planning Approval
Called Contact.Person
A.I.P.P..
Pub. Wks. Appr,
Date of permit issue
School Fees
Total rerniiI secs
PROUDLY SERVING THE
UNINCORPORATED AREAS
OF RIVERSIDE COUNTY
AND THE CITIES OF:
BANNING
BEAUMONT
CALI M ESA
CANYON LAKE
C OAC H E LLA
DESERT HOT SPRINGS
EASTVALE
INDIAN WELLS
INDIO
JURUPA VALLEY
LAKE ELSINORE
LA QUINTA
MENIFEE
MORENO VALLEY
NORCO
PALM DESERT
PERRIS
RANCHO MIRAGE
RUBIDOUX CSD
SAN JACINTO
TEMECULA
WILDOMAR
BOARD OF
SUPERVISORS:
KEVIN JEFFRIES
DISTRICT 1
JOHN TAVAGLIONE
DISTRICT 2 .
JEFF STONE
DISTRICT 3
JOHN BENOIT
DISTRICT 4
MARION ASHLEY
DISTRICT 5
RIVERSIDIE COUNTY FIRE DEPARTMENT
IN COOPERATION WITH
THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION
77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 922114131 • Phone (760) 863-8886
• Fax (760) 863-7072
www. rvcfire.org
May 15th, 2015
RE: , TENANT IMPROVEMENT PLAN CHECK -Non Structural
LAQ-I5-TI-018 Old, Town Artisan'Studio 78134 Calle Tampico,Suite #160 La Quinta, CA
You have been issued an approved for a tenant improvement on an existing building. THIS IS NOT
AN OCCUPANCY PERMIT.
It is prohibited to use/process or store any materials in this occupancy that would classify it as a '"H"
occupancy per Sec. 307 of the 2013 CBC.
THE FOLLOWING CONDITIONS MUST BE MET PRIOR TO INSPECTION:
Install door hardware and exit signs as per Chapter 10 of the 2013 CBC.
A minimum 2AIOBC Fire Extinguisher, (State Fire Marshal Approved) must be mounted in a visible
location within 75' walking distance from any point in your building or suite. Fire extinguishers can
be installed by a licensed extinguisher company with a State Fire Marshal service tag attached to the
extinguisher, or purchased from a retail store with a sales receipt attached. A licensed fire
extinguisher company must service extinguisher yearly.
All breakers must be labeled and a clearance of 36 inches must be maintained'around the panel ai all
times.
Approved suite addresses shall be placed in such a position ,to be plainly visible and legible from the
I treet. Said numbers shall contrast with their background.
An approved audible interior notification alarm device shall be provided in approved location. A C-
10 licensed contractor must submit plans, designed in accordance with NFPA 72 to the Fire
Department for review and approval prior to installation
A durable sign stating "This door to remain unlocked during business hours" shall be placed on o-
adjacent to the front exit door. The sign shall be in letters not less than one inch high on a
contrasting background.
Provide key(s) to the tenant space for inclusion in the main building Knox, Box. Key(s) shall have
durable and legible tags affixed for identification of the correlating, tenant space. Key(s) shall be
provided at time of final inspection.,
As may be necessary to maintain proper fire sprinkler protection due to constructions changes, fire
sprinkler system plans- for the tenant improvement area may be required to be submitted to the Firo
Department for review and for relocation of sprinkler heads.(Sprinkler system may need a 5 year
certification before final is given)
Air handling systems supplying air in excess of 2000 cubic feet per minute to enclosed spaces within
buildings shall be equipped with an automatic shutoff. 2013 CMC(Sheet Number M 1.0).
A UL300 hood/duct fire extinguishing system must be installed over the cooking equipment as
required by the California Fire Code, California Mechanical Code and adopted standards. System
plans must be submitted to the Fire Department for review, along with current plan check/inspecdon
'fee.
SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing
structural integrity. Review of this plan does not authorize or approve any omission or deviation.
from all applicable regulations. Final approval is subject to field inspection.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. A re-
inspection fee will be required if more than one (1) inspection is necessary. Requests for inspections
are to be made at least 72 hours in advance and may be arranged by calling (760),863-8886.
All questions regarding the meaning of these conditions should be referred to the Fire Department
Planning & Engineering Staff at (760) 863-8886.
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Old Town Artisan Studio .
78-134 Calle Tampico #160•,
,La Quinta, .CAA 92253 ,
w. Project Designer:
AA Design 1
x 817692 Rancho Santana Dr.
_ La Quinta, CA•92253 `
' 760-272-4285
Report Prepared by:
CITY OF LA QUINTA Gina Rose
BUILDING & SAFETY DEPT. EQS, Inc.
APPROVED P.O. Box 170 .
FOR CONSTRU TION Go Hill, OR.97525
DATE 60-218-3350
zftWEIVED
MAR 312015 -
Job Number: .
Q
CITY OF LA QUINTA '
COMMUNITY DEVELOPMENT +
Date:
The EnerpPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the. Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com. = "
Ene P_ro 6.4_b .Ene SoFt User Number: 5862 ID:
I� ,
x
TABLE OF CONTENTS
Cover Page
1
Table of Contents
2
Form ENV -01 -E Envelope Component Approach
3
Form ENV -02-E Fenestration Worksheet
7
Form ENV -MM Envelope Mandatory Measures
9,
Form LTI-01-E Indoor Lighting
10
Form LTI-02-E Lighting Controls
15
Form LTI-03-E Indoor Lighting Power Allowance,
18
Form MCH -01-E Mechanical Systems - ,
20
Form MCH -02-E HVAC System Requirements
23
Form MCH -03-E Mechanical Ventilation and Reheat
25
Form MCH -04-E Required.Acceptance Tests
27
Form PLB-01-E Water Heating System'
30
HVAC System Heating and Cooling Loads Summary.
e
32
f
`1
t .
• f
f
EnergyPro 6.4 by EnergySoft Job Number: ID: User Number: 5862
STATE OF CALIFORNIA
ENVELOPE COMPONENT APPROACH
CEC-NRCC-ENV-01-E Revised 06/14 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-ENV-01-E
Envelope Component Approach (Page 1 of 4)
Project Name: Old Town Artisan Studio Date Prepared: 3/29/2015
A. GENERAL INFORMATION
1
1
Project Location: 78.134 Calle Tampico #160
6 Compliance Method:
0 Component ❑ Unconditioned (file
6
7
8
Affidavit)
2
CA City and Zip Code: La Qulnta, 92253
7 Building Front Orientation (deg or cardinal):
180 deg
3
Climate Zone: 15
8 Permitted Scope of Work I ❑ New Construction ❑ Addition ❑ Alteration
4
Total Conditioned Floor
2,480
9 Building Type(s)
m Nonresidential ❑ High -Rise Residential ❑ Hotel/Motel Guest Room
Required U -Factor From
Tables, B, C, D
Area:
1
Wall
5
❑Schools (Public School) ❑ Relocatable Public School Bldg. la Conditioned Spaces
❑ Unconditioned Spaces
14.3.1-A5 119
❑ Skylight Area for Large Enclosed Space > 5000 ftZ (If checked include the NRCC-ENV-04-E with submittal)
B. ENVELOPE DETAILS — Framed
1
2
3
4
5
6
7
8
9
10
11
Tag/ID
Assembly Type
Frame
Material
Frame
Depth
Frame
Spacing
Appendix JA4
Reference
Cavity
R -value
Continuous
Insulation
R -value
Proposed
U -Factor
Required U -Factor From
Tables, B, C, D
Comments
1
Wall
Wood
2x6 @ 16
1
14.3.1-A5 119
0.500
10.0
10.074
0.074
R-19 Wall
2
1 Roof
Wood
12x4 @ 24
1
14.2.1-A20
130
10.0
10.031
10.031
R-30 Roof Attic
C. ENVELOPE DETAILS — Non -framed
1
2
3
4
5
6
7
8
9
10
Tag/ID
Assembly Type
Assembly Materials
'
Thickness
(inches)
Interior or
Core
Insulation
. R -value
Continuous
Insulation
R -value
Appendix JA4
Reference
Proposed
U -Factor
Required U -Factor from
Tables, B, C, D
Comments
1
Door
Metal, Fire rated
0
0.0
4.5.1-A3
0.500
0.500
Insulated Metal Door
D. ENVELOPE DETAILS - Mass
1
2
3
4
5
6
7
8
9
10
11
Tag/ID
Mass
Type
Density
(Ib/ft3l
Mass
Thickness
(inches)
Furring Strip
Thickness
(inches)
Interior
Insulation
R -value
Exterior
Insulation
R -value
Appendix JA4
Reference
Proposed
Insulation
U -factor
Required U -Factor from
Tables, B, C, D
Comments
CA Building limigy CfPLienLy 51.6nJai-di - 2013 Nonre3identiol Complienee Juno 2014
STATE OF CALIFORNIA
ENVELOPE COMPONENT APPROACH
CEG-NRCC-ENV-01-E Revised 06/14 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-ENV-01-E
Envelope Component Approach (Page 2 of 4)
Pr°le" Name: Old Town Artisan Studio Date Prepared: 3/29/2015
E. ROOFING PRODUCTS (COOL ROOF)
1
2
3
4
5 6 7
8 9 -10
11
Mass Roof
Whole Building
Air Leakage Testing
Comments
Proposed
Minimum Required
Aged Solar
Thermal
SRI
Aged Solar
Thermal
SRI
• 25 Ib ft2
CRRC Product
or greater
Roof Pitch
ID Number
Product Type
Reflectance
Emittance
(Optional)
Reflectance
Emittance
(optional)
Comments
❑
❑'
❑
❑'
❑
❑'
❑ An aged solar reflectance less than 0.63 is allowed provided the maximum roof / ceiling U -factor in TABLE 140.3 is not exceeded
❑ High-rise residential buildings and Hotels and Motels with low -sloped roofs in Climate Zones 1 through 8, 12 and 16 are exempted from aged Solar
Reflectance and emittance requirements.
❑ High-rise residential buildings and Hotels and Motels with steep -sloped roofs in Climate Zones 1 and 16 are exempt from aged Solar Reflectance and
emittance requirements.
❑ The roof area covered by building integrated photovoltaic panels and building integrated solar thermal panels are exempt from aged Solar Reflectance
and emittance requirements
To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage recommended
by the coatings manufacturer and meet minimum performance requirements listed in §110.8(i)4. Select the applicable coating:
❑ Aluminum -Pigmented Asphalt Roof Coating
❑ Cement -Based Roof Coating
❑ Other
NOTES:
1. Check the box if the aged Solar reflectance was not available in the Cool Roof Rating Council's Rated Product Directory, Then use the equation in Section 110.8(i)2 where the Initial Reflectance
value from the some directory and use the equation (0.2+B(pjnjtj,j — 0.2) to obtain a calculated aged value. Where p is the Initial Solar Reflectance and B is either set to 0.65 for Field -Applied
Coatings or it is set to 0. 70for all other roofing products other than Field -Applied Coating.
2. Calculate the SRI Value by using the SRI -Worksheet at (TBD) and enter the resulting value in the SRI Column above and attach a copy for the SRI -Worksheet NRCC-ENV-03-E to the to this form.
F. Air Barrier
1
- 2
3
4
5
Tag/ID
Air Barrier
Material Type
Air Barrier
Assembly Type
Whole Building
Air Leakage Testing
Comments
CA Building Energy Efficiency Standards - 2013 Non. residentidl Cgrripliance Jung 2014
STATE OF CALIFORNIA
ENVELOPE COMPONENT APPROACH
CEC-NRCC-ENV-01-E Revised 06/14 CALIFORNIA ENERGY COMMISSION"
CERTIFICATE OF COMPLIANCE NRCC-ENV-01-E
Envelope Component Approach (Page 3 of 4)
Pmlect"ame: Old Town Artisan Studio Date Prepared: 3/29/2015
G. FENESTRATION PROPOSED AREAS AND EFFICIENCIES
1
2
3
4
5
6
7
8
9
10
11
12
Tag/ID
Fenestration Type
Area
Orientation
N, S, W, E.
or Roof
# of
Panes
Max
U -Factor
Overhang
Max
(R)SHGC
Min
VT
Label
Conditions
Status
Comments
H. ENVELOPE MANDATORY MEASURES
Indicate location on building plans of Mandatory Envelope Measures Note Block: ENV -MM
INSTRUCTIONS TO APPLICANT ENVELOPE COMPLIANCE & WORKSHEETS (check box if worksheet are included)
For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Compliance Manual.
0 NRCC-ENV-01-E -Certificate of Compliance. Required on plans for all submittals.
❑ NRCC-ENV-04-E Use when minimum skylight requirements for large enclosed spaces are required in climate zones 2 through 15. Optional on plans.
r A Rpilriin8 Fnprgy Fffirianry Stpndarric . 7Q13 Mnnrgcidapthl CQrrPIiancq June 2014
STATE OF CALIFORNIA
ENVELOPE COMPONENT APPROACH
CEC-NRCC-ENV-01-E Revised 06/14 CALIFORNIA ENERGY COMMISSION �_
CERTIFICATE OF COMPLIANCE NRCC-ENV-01-E
Envelope Component Approach (Page 4 of 4)
Project Name: Old Town Artisan Studio Date Prepared: 3/29/2015
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Gina ROS@ Documentation Author Signature:
Company:. EQS, Inc.
signature Date: 3/29/2015 --
Address: P.O. BOX 170
CEA/ HERS Certification Identification (if applicable):
City/state/zip: Gold HIII , OR 97525
Phone: 760-218-3350
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible
designer).
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance
conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval.with this building permit application_
5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement
agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the
building owner at occupancy.
Responsible Designer Name:
Responsible Desi Signature: "
Company: AA Design
Date Signed:
Address` 81-692 Rancho Santana Dr.
License:
City/State/Zip: La Quinta, CA 92253
Phone: 760-272-4285
t
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance
• f
June 2014
STATE OF CALIFORNIA
FENESTRATION WORKSHEET
CEC-NRCC-ENV-02-E (Revised 06/14) CALIFC
ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-ENV-02-E
Fenestration Worksheet (Page 1 of 3)
Project Name: Old Town Artisan Studio Date Prepared: 3/29/2015
A. WINDOWS DETAILS Worksheet §140.3(a)5B and C
NOTE: Newly installed fenestration shall have a certified NFRC Label Certificate or use the CEC default tables found in Table 116-A and
Table 1168. Site -built fenestration less than 1,000 ft, or more than or equal tot, 000 ft2 see Reference Nonresidential Appendix NA6.
1
2
3
. 4 1 5 1 6 1 7 8 1 9
10 1 11 12 13 14
Tag/I
D
Window Type
(e.g., Window -1)
Aread0.79O
Fenestration
Maximum Standard West Area
Overhang
U -Factor I
SHGC
VT
E. Gross Exterior Wall Area
Dimensions
ft2 x 0.40 = 762 40% of Gross Exterior Wall Area or
Calculated
3
o2
Q
o-
3
Q
C
2
a-
3
¢
H
V HIV
(R)SHGC
Proposed
Max
(R)SHGC
Allowed
1
Window
85
0.790
0.700
0.700
0.5000.502
Window
229
0.790
0.700
0.700
0.500
0.50(
B. WEST WINDOW AREA CALCULATION See §140.3(a)5A
in the Energy Standards
A. Gross West Exterior Wall Area0
ft2 x 0.40 = 0 ft2
40% of Gross West Facing Exterior Wall Area; or
B. West Display Linear Perimeter J
0
FT x 6 ft = 0 ft2
West Display Perimeter Area
C. Enter Larger of A or B 0 ft2
Maximum Standard West Area
D. Enter Proposed West Window Area 0 ft2
Proposed West Window Area
Note: If the PROPOSED WEST WINDOW AREA is greater than the MAXIMUM STANDARD WEST AREA then the envelope component
approach may not be used.
C. WINDOW AREA CALCULATION for all other orientations other than West - See §140.3(a)5A in the Energy Standards
E. Gross Exterior Wall Area
1,904
ft2 x 0.40 = 762 40% of Gross Exterior Wall Area or
F. Linear Display Perimeter:::d
0
FT x 6 ft = 0 ft2 Display Perimeter Area
G. Enter The Larger of E or F 762 ft2 Maximum Standard Area
H. Enter Proposed Window Area 314 ft2 1 Proposed Window Area
Note: If the PROPOSED WINDOW AREA is greater than the MAXIMUM STANDARD AREA then the envelope component approach may
D. SKYLIGHT AREA CALCULATION See §143(a)6A in the Energy Standards
ACTUAL GROSS
ROOF AREA
STANDARD
ALLOWED
A IF Atrium/Skylight Height is <_ 55 ft; or
2,480
ft2 x 0.05 =
124 ft2
ft2
B. IF Atrium/Skylight Height is > 55 ft
ft2 x 0.10 =
C. Proposed Skylight Area (from plans)
0 fe
D. Skylight SSR %' z = Proposed Skylight Area Divided by Actual Gross
0.0 _ %
1. If the SKYLIGHT SSR % is less than or equal to 5% then choose the appropriate column in Table 140.3-B and C and row in Table 140.3-D.
2. If the SKYLIGHT SSR % is greater than 5% then the Envelope Component Approach may not be used.
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014
STATE OF CALIFORNIA
FENESTRATION WORKSHEET
CEC-NRCC-ENV-02-E (Revised 06/14)
ENERGY COMMISSION .
CERTIFICATE OF COMPLIANCE
Fenestration Worksheet
Project Name: Old Town Artisan Studio
CALIFC
N RCC -ENV -02-E
' (Page 3 of 3)
Date Prepared: 3/29/2015
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:'
Gina Rose r�
Company: EQS, Inc.
signature Date: 3/29/2015
Address: P.O. BOX 170
CEA/ HERS Certification Identification (if applicable):
City/State/Zip: Gold Hill, OR 97525
phone: 760-218-3350
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified
on this Certificate of Compliance (responsible designer).
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system
design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information
provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement
agency for approval with this building permit application.
5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this
Certificate of Compliance is required to. be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Responsible D' Signature:
Company: AA Design
Date Signed:
-'3o-rte
Address: 81-692 Rancho Santana Dr.
License:
City/state/Zip: La Quinta, CA 92253
phone: 760-272-4285
11
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance
a
June 2014
x
ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL ENV -MM'
Project Name
Date t
Old Town Artisan Studio
3/29/2015
DESCRIPTION
Building Envelope Measures:
§110.8(a): Installed insulating material shall have been certified by the manufacturer to comply with the California Quality
Standards for insulating material, Title 20 Chapter 4; Article 3.
All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of
§110.8(c):
Sections 2602 and 707 of Title 24, Part 2.
§1.10.8(f): The -opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value
of no less than R-13 between framing members.
§110.7(a): All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed,
weatherstripped or otherwise sealed.
Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.2 of
§110.6(a): window area, 0.3 cfm/ft.z of door area for residential doors, 0.3 cfm/ft.' of door area for nonresidential single doors
(swingingand slidin and 1.0 cfm/ft.2 for nonresidential double doors (swinging).
§110.6(a): Fenestration U -factor shall be rated in accordance with NFRC 100, or the applicable default U -factor.
§110.6(a) : Fenestration SHGC shall berated in accordance with NFRC 200, or NFRC 100 for site -built fenestration, or the
applicable default SHGC.
§110.6(b): Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be
weatherstripped (except for unframed glass doors and fire doors).
t .
F
{
EnergyPro 6.4 by EnergySoft User Number 5862 RunCode: 2015-03-29709:08:19 ID: Page 9 of 32
ih
�
Y
STATE OF CALIFORNIA
INDOOR LIGHTING
CEC-NRCC-LTI-01-E Revised 06/14 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E
Indoor Lighting (Page 1 of 5)
Project Name: Old Town Artisan Studio Date Prepared: 3/29/2015
Climate Zone:
15
Conditioned Floor Area: 2,480
YES NO FORM
TITLE -
YES NRCC-LIT-01-E
Certificate of Compliance. All Pages required on plans for all submittals.
Unconditioned Floor Area : 0
Lighting Controls, Certificate of Compliance, and PAF Calculation. All Pages required on plans for all submittals.
General Information
Indoor Lighting Power Allowance
NO NRCC-LIT-04-E
Tailored Method Worksheets
NO NRCC-LIT-05-E
Line Voltage Track Lighting Worksheets
Building Type:
❑ Schools
El Nonresidential
❑ Relocatable Public Schools
❑
El
High -Rise Residential
Conditioned Spaces
❑
❑
Hotel/Motel
Unconditioned Spaces
Phase of Construction:
❑ New Construction
❑
Addition
❑
Alteration
Method of Compliance:
❑ Complete Building
❑
Area Category
0
Tailored
LIGHTING COMPLIANCE DOCUMENTS (select yes for each document included)
For detailed instructions on the use of this and all Energy Efficiency Standards compliance documents, refer to the Nonresidential Manual published by the California Energy Commission.
YES NO FORM
TITLE -
YES NRCC-LIT-01-E
Certificate of Compliance. All Pages required on plans for all submittals.
YES NRCC-LIT-02-E
Lighting Controls, Certificate of Compliance, and PAF Calculation. All Pages required on plans for all submittals.
YES NRCC-LIT-03-E
Indoor Lighting Power Allowance
NO NRCC-LIT-04-E
Tailored Method Worksheets
NO NRCC-LIT-05-E
Line Voltage Track Lighting Worksheets
Summary of Allowed Lighting Power
Conditioned and Unconditioned space Lighting must not be combined for compliance
Indoor Lighting Power for Conditioned Spaces
Indoor Lighting Power for Unconditioned Spaces
Watts
Watts
Installed Lighting
Installed Lighting
3,940
0
1.
NRCC-LTI-01-E, page 4
+
NRCC-LTI-01-E, page 4
+
PORTABLE ONLY FOR OFFICES
2.
NRCC-LTI-01-E, page 3
+
Minus Lighting Control Credits
985
Minus Lighting Control Credits
0
3'
NRCC-LTI-02-E, page 2
NRCC-LTI-02-E, page 2
4.
Adjusted Installed Lighting Power
_
2955
Adjusted Installed Lighting Power
_
0
(row 1 plus row 2 minus row 3)
(row 1 minus row 3)
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance . June 2014
STATE OF CALIFORNIA
INDOOR LIGHTING
CEC-NRCC-LTI-01-E Revised 06/14)CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E
Indoor Lighting (Page 2 of.5)
Project Name: Old Town Artisan Studio Date Prepared: 3/29/2015
5.
Complies ONLY if Installed <_ Allowed
Complies ONLY if Installed :5 Allowed
Form/Title
6.
Allowed Lighting Power
Conditioned NRCC-LTI-03-E, page 1
496
Allowed Lighting Power
Unconditioned NRCC-LTI-03-E, page 1
0
Declaration of Required Installation Certificates — Declare by selecting yes for all Installation Certificates that will be submitted. (Retain copies and verify forms are
completed and signed.)
YES
NO
Form/Title
NRCI-LTI-01-E - Must be submitted for all buildings
❑ Field inspector
NRCI-LTI-02-E - Must be submitted for a lighting control system, or for an Energy Management Control System (EMCS),
to be recognized for compliance. _
❑ Field Inspector
NRCI-LTI-03-E - Must be submitted for a line -voltage track lighting integral current limiter, or for a supplementary
overcurrent protection panel used to.energize only line -voltage track lighting, to be recognized for compliance.
❑ Field Inspector
NRCI-LTI-04-E - Must be submitted for two interlocked systems serving an auditorium, a convention center, a
conference room, a multipurpose room, or a theater to be recognized for compliance.
❑ Field Inspector
NRCI-LTI-05-E - Must be submitted for a Power Adjustment Factor (PAF) to be recognized for compliance.
❑ Field Inspector
NRCI-LTI-06-E - Must be submitted for additional wattage installed in a video conferencing studio to be recognized for
compliance.
❑ Field Inspector
Declaration of Required Certificates of Acceptance — Declare by checking all of the Certificates of Acceptance that will be submitted. (Retain copies and verify forms are
completed and signed.)
YES
NO
Form/Title
NRCA-LTI-02-A - Must be submitted for occupancy sensors and automatic time switch controls.
❑ Field Inspector
NRCA-LTI-03-A - Must be submitted for automatic daylight controls.
❑ Field Inspector
NRCA-LTI-04-A - Must be submitted for demand responsive lighting controls.
❑ Field Inspector
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014
STATE OF CALIFORNIA
INDOOR LIGHTING
CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS NRCC-LTI-01-E
Indoor Lighting (Page 3 of 5)
Project Name: Old Town Artisan Studio Date Prepared: 3/29/2015
A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for.
® CONDITIONED SPACE ❑ UNCONDITIONED SPACE
A. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST
❑ The actual indoor lighting power listed on this page and on the next page includes all installed permanent and planned portable lighting systems.
❑ When Complete Building Method is used for compliance, list each different type of luminaire on separate lines.
❑ When Area Category Method or Tailored Method is used for compliance, list each different type of luminaire by each different function area on separate lines
❑ Also include track lighting in schedule, and submit the track lighting compliance form (NRCC-LTI-05-E) when line -voltage track lighting is installed.
B. Installed Portable Luminaires in Offices — Exception to Section 140.6(a) -
❑ This section shall be filled out ONLY for portable luminaires in offices (As defined in §100.1). All other planned portable luminaires shall be documented on next page of
this compliance form.
❑ This section is used to determine if greater than 0.3 watts of portable lighting is planned for any office
❑ Fill out a separate line for each different office. Small offices that are typical (having the same general and portable lighting) may be grouped together. This allowance
shall not be traded between offices having different lighting systems..
Office Portable Luminaire
Office Installed Portable Luminaire Watts Per Square
Office Location
Field
Schedule
Foot
Inspector
A
B
C
D
E
F
G
H
I
J
Installed
r- Z
portable
9 v+
Watts
If F5 0.3,
Identify Office area in which
3 3
luminaire
N
per
enter zero;
Complete Luminaire Description
C
watts in this
o`,
°
square
E x G
these portable luminaires are
N
d
(i.e., LED, under cabinet, furniture mounted
Watts per
M o
—
office
m .»
foot
if F > 0.3,
installed
direct/indirect)
Luminaire
(B x C)
(D / E)
(F-0.3)
❑
❑
20
a;
Enter sum total of all pages into NRCC-
Total installed portable luminaire watts that are greater than 0.3 watts per square foot per office:
LTI-01-E; Page 1
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014
STATE OF CALIFORNIA
INDOOR LIGHTING .
CEC-NRCC-LTI-01-E Revised 06/14
CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS
Indoor Lighting
Project Name: Old Town Artisan Studio
J
CALIFORNIA ENERGY COMMISSION
- NRCC-LTI-01-E
(Page 4 of 5)
Date Prepared: 3/29/2015
carate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for:
;ONDITIONED SPACE ❑ UNCONDITIONED SPACE
C. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST '
Luminaire Schedule
Installed Watts
Location
Field Inspector'
A
B
C
D
E
F
G
H
How wattage was.
-
determined
1.
..
Vi O
o, °�'
-
Complete Luminaire Description
r
,f1 n
c n o
r
C
3 z
- 7 d
3
•
I� E
(i.e, 3 lamp fluorescent troffer,
o', v
Z M o
d. 3
x a
Primary Function area in which
Z,=
F32T8, one dimmable electronic ballast)
m r9
co
cu
these luminaires are installed
Pass
fail
(4) 8 ft Fluorescent
124.0
® ❑
20
2,480
Comp Bldg Classroom
❑
; ❑ `';
a
6" recessed LED
14.0
® ❑
4
56 -
Comp Bldg Classroom
,,, ❑
(2) 2 ft Fluorescent T8 Elec
54.0
® ❑
6
324
Comp Bldg Classroom7.
❑ & r
.0
(2) 4 ft Fluorescent T8 Energy Savings Elec
54.0
El ❑ "
20
1,080
Comp Bldg Classroom -.
;❑ �„
❑ rF
❑ ❑
xa❑
;.
❑ ❑
Y
0
❑ ,:
❑
0
❑
❑ ❑.o
❑�e
- = INSTALLED WATTS PAGE TOTAL:
940
Enter sum total of all pages into
` -
NRCC-LTI-01-E; Page 2
I
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance
_ - June 2014
STATE OF CALIFORNIA
INDOOR LIGHTING
CEC-NRCC-LTI-01-E Revised 06/14
CERTIFICATE OF COMPLIANCE - USER INSTRUCTIONS
1"Indoor Lighting
Project Name: Old Town Artisan Studio
Date Prepared: 3/29/2015
4,
JISSION
NRCC-LTI-01-E
(Page 5 of 5)
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT '
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Signature: -1
Documentation Author Name: .
Gina Rose - -
Company: EQS, Inc. signature Date:3/Z9/ZO15
Address: P.O. BOX 170
CEA/ HERS Certification Identification (if applicable): `
City/State/Zip: Gold Hill, OR 97525
Phone: 760-218-3350
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury„under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance
(responsible designer).
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of -
Compliance conform to the requirements of Title 24, Part land Part 6 of the California Code of Regulations. -
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance '
documents, worksheets, calculations, plans and specifications submitted to the enforcement°agency for approval with this,building permit application.
5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the
enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the
builder provides to the building owner at occupancy.
Responsi a Desi ner Name: -
Responsible Designer Signate:
oo
Company: (1��
Date Signed' ��
Address:•�J� y
License:
City/State/Zip:
Phone:
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance - June 2014
STATE OF CALIFORNIA
INDOOR LIGHTING — LIGHTING CONTROLS
ENERGY
CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E
,Indoor Lighting - Lighting Controls (Page 1 of 3)
Project Name: Old Town Artisan Studio Date Prepared:
3/29/2015
The NRCC-LTI-02-E shall be used to document all mandatory and prescriptive lighting controls that are applicable to the project.
Mandatory Lighting Control Declaration Statements (Indicate if the measure applies by checking yes or no below.)
YES
NO
Control Requirements
Lighting shall be controlled by self-contained lighting control devices which are certified to the Energy Commission according to the Title 20 Appliance
Efficiency Regulations in accordance with Section 110.9.
Lighting shall be controlled by a lighting control a system or energy management control system in accordance with §110.9. An Installation Certificate
shall be submitted in accordance with Section 130.4(b).
One or more Track Lighting Integral Current Limiters shall be installed which have been certified to the Energy Commission in accordance with §110.9 and
§130.0. Additionally, an Installation Certificate shall be submitted in accordance with Section 130.4(b).
A Track Lighting Supplementary Overcurrent Protection Panel shall be installed in accordance with Section 110.9 and Section 130.0. Additionally, an
Installation Certificate shall be installed in accordance with Section 130.4(b).
All lighting controls and equipment shall comply with the applicable requirements in §110.9 and shall be installed in accordance with the manufacturer's
instructions in accordance with Section 130.1.
All luminaires shall be functionally controlled with manually switched ON and OFF lighting controls in accordance with Section 130.1(a).
General lighting shall be separately controlled from all other lighting systems in an area. Floor and wall display, window display, case display, ornamental,
and special effects lighting shall each be separately controlled on circuits that are 20 amps or less. When track lighting is used, general, display,
ornamental, and special effects lighting shall each be separately controlled; in accordance with Section 130.1(a)4.
The general lighting of any enclosed area 100 square feet or larger, with a connected lighting load that exceeds 0.5 watts per square foot shall meet the
multi-level lighting control requirements in accordance with Section 130.1(b).
All installed indoor lighting shall be equipped with controls that meet the applicable Shut -OFF control requirements in Section 130.1(c).
Lighting in all Daylit Zones shall be controlled in accordance with the requirements in Section 130.1(d) and daylit zones are shown on the plans.
Lighting power in buildings larger than 10,000 square feet shall be capable of being automatically reduced in response to a Demand Responsive Signal in
accordance with Section 130.1(e).
Before an occupancy permit is granted for a newly constructed building or area, or a new lighting system serving a building, area, or site is operated for
normal use, indoor lighting controls serving the building, area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in
accordance with Section 130.4.(a). The controls required to meet the Acceptance Requirements include automatic daylight controls, automatic shut -OFF
controls, and demand responsive controls.
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014
STATE OF CALIFORNIA
INDOOR LIGHTING — LIGHTING CONTROLS
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E
Indoor Lighting - Lighting Controls (Page 2 of 3)
Project Name: Old Town Artisan Studio Date Prepared: 3/29/2015
A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following:
0 CONDITIONED SPACES O UNCONDITIONED SPACES
MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST
PAF Credit Calculation 2
n
(D
D
_n
FD
a
Standards Complying With 1
o �
r) o
o :3�•
Lighting Control Schedule
(✓ all that apply, or enter 'E' if Exempted)
w CL o
-n
v a o
o. g
-
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
Type/ Description of Lighting
Control (i.e.: occupancy sensor,
#
N
)LoN
N
a
Location in Building
automatic time switch,
of
o
0
0
0
0
P
o
dimmer, automatic daylight,
Units
v
etc...)
Suite
Dimming w/Occ Sensor
✓
324
0.25
81
•✓
❑
[3
Suite
Dimming w/Occ Sensor
✓
1,080
0.25
270
✓
❑
❑-;•
Suite
Dimming w/Occ Sensor
✓
2,480
0.25
620
✓
❑
'E
Suite
Dimming w/Oc : Sensor
✓
56
0.25
14
✓
< ❑
❑
0.
Control Credit PAGE TOTAL (Sum of Column M):
985
IF MULTIPLE PAGES ARE USED, ENTER SUM TOTAL OF Control Credit for all pages HERE (Sum of all Column M):
985
Enter Control Credit total
into NRCC-LTI-01-E; Page
1.
1. §130.1(a) = Manual area controls; §130.0(b) = Multi Level; §130.1(c) =Auto Shut -Off; §130.1(d) =Mandatory Daylight; §130.1(e) = Demand Responsive; §140.6(d) =
Additional lighting controls installed to earn a PAF; §140.6(d) = Prescriptive Secondary Sidelit Daylight Controls.
2. Check Table 140.6-A for correct Factor. PAFs shall not be traded between conditioned and unconditioned spaces. As a condition to earn a PAF, an Installation Certificate is
also required to be filled out, signed, and submitted.
CA Buildiw Energy EfficiencyStandards - 2()13 NnnrPsiriential Cnmplianre Juno 2014
STATE OF CALIFORNIA
INDOOR LIGHTING - LIGHTING CONTROLS
CEC-NRCC-LTI-02-E Revised 06/14 CALIFORNIA ENERGY COMMISSION --AMWO"
CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E
Indoor. Lighting -Lighting Controls (Page 3 of 3)
Project Name: Old Town Artisan Studio - - Date Prepared: 3/29/2015
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature: m ' 77
Gina Rose
company: EQ$, Inc. signature Date: 3/29/2015
Address: P.O. BOX 170
CEA/ HERS Certification Identification (if applicable):
City/state/Zip: Gold Hill, OR 97525
Phone: 760-218-3350
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.,
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance
- (responsible designer). _
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of
Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance
documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the
enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the
builder provides to the building owner at occupancy.
Responsible Designer NaR
'Responsible Designer Signature
Compa y .74P DG25
Date Signed:
`J
Address:
License:
City/State/Zip:
Phone:
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance T s - t_ _ , ._ _ . , _ _ _ _ __ _ . __ _._ _ - _ 1une.2014 _ -
STATE OF CALIFORNIA -
INDOOR LIGHTING POWER ALLOWANCE,
CEC-NRCC-LTI-03-E Revised 06/14 CALIFORNIA ENERGY COMMISSION '
CERTIFICATE OF COMPLIANCENRCC-LTI-03-E
Certificate of Compliance - Indoor Lighting Power Allowance (Page 1 of 4)
Project Name: Old Town Artisan Studio - - Date Prepared' 3/29/2015 - -
ALLOWED LIGHTING POWER
A separate page must be filled out for Conditioned and Unconditioned Spaces. This page is 'only for:
0 CONDITIONED spaces• ❑ UNCONDITIONED spaces ,
A. SUMMARY TOTALS OF LIGHTING.POWER ALLOWANCES ,
❑ If using Complete Building Method for compliance, use only the total in column (a) es total allowed building watts.
❑ .If using Area Category. Method, Tailored Method, or a combination of Area Category and Tailored Method for compliance, use only the total in column (b) as the total
allowed building watts . r
'(a) (b)
1. Complete Building Method Allowed Watts. Documented in section B of NRCC-LTI-03-E (below on this page):-
2.• Asea Category Method Allowed Watts;. Documented in section C-1'of NRCC-LTI-03-E (below on this page)
0
3. Tailored Method Allowed Watts. Documented in section A of NRCC-LTI-04-E ' - 496 -
,
• TOTAL ALLOWED BUILDING WATTS. Enter number into correct cell on NRCC-LTI-01, Page 2, Row 1 496
❑ Check.here if building contains both conditioned and unconditioned areas. -
B. COMPLETE BUILDING METHOD LIGHTING POWER ALLOWANCE
.. A -
g
0
C
'0
D
0
WATTS'
COMPLETE.
ALLOWED
TYPE OF BUILDING (From §140.6 Table 140.676) '"
PER (ftZ)
X
BLDG. AREA
=
WATTS
Total:Area;.
Total Watts. Enter Total Watts into section A, row l (Above on this page)
•
C.-1 AREA CATEGORY METHOD TOTAL LIGHTING, POWER ALLOWANCES (C-2.plus.0-3)
Watts
Total from section C-2
0
' -Total from section C-3 :
'0
Total Watts. Enter Total Watts into section A, row 2 (Above on this page)
0
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance '. June 2014'
STATE OF CALIFORNIA
INDOOR LIGHTING POWER ALLOWANCE
CEC-NRCC-LTI-03-E Revised 06/14 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCGLTI-03-E
Certificate of Compliance - Indoor Lighting Power Allowance (Page 4 of 4)
Project Name: Old Town Artisan Studio Date Prepared: 3/29/2015
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1.. I certify that this Certificate of Compliance documentation is accurate and complete. M
Documentation Author Name: Documentation Author Signature:
Gina Rose -
Company: EQS, Inc.
signature Date: 3/29/2015
Address: P.O. Box 170
CEA/ HERS Certification Identification (if applicable)-
City/State/Zip: Gold Hill, OR 97525
Phone: 760-218-3350
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance
(responsible designer).
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of
Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance
documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the
enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the
builder provides to the building owner at occupancy.
Responsible Designer Namp�
Responsible Designer Signatu
/�/
Company:
Date Signed:
Address:
License:
City/State/Zip:
Phone:
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014
STATE OF CALIFORNIA
MECHANICAL SYSTEMS
CERTIFICATE OF COMPLIANCE NRCC-MCH-01-E.
Mechanical Systems (Page 1 of 3)
Project Name: Old Town Artisan Studio Date Prepared: 3/29/2015
MECHANICAL COMPLIANCE FORMS & WORKSHEETS (check box if worksheet is included)
For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, refer to the 2013 Nonresidential Manual
Note: The Enforcement Agency may require all forms to be incorporated onto the building plans.
YES NO Form/Worksheet #
Title
E3 ❑ NRCC-MCH-01-E (Part 1 of 3)
Certificate of Compliance, Declaration. Required on plans for all submittals.
En ❑ NRCC-MCH-01-E (Part 2 of 3)
Certificate of Compliance, Required Acceptance Tests (MCH -02A to 11A). Required on plans for all submittals.
0 ❑ NRCC-MCH-01-E (Part 3 of 3)
Certificate of Compliance, Required Acceptance Tests (MCH -12A to 18A). Required on plans where applicable.
® ❑ NRCC-MCH-02-E (Part 1 of 2)
Mechanical Dry Equipment Summary is required for all submittals with Central Air Systems. It is optional on plans.
m ❑ NRCC-MCH-02-E (Part 2 of 2)
Mechanical Wet Equipment Summary is required for all submittals with chilled water, hot water or condenser water
systems. It is optional on plans.
El ❑ NRCC-MCH-03-E
Mechanical Ventilation and Reheat is required for all submittals with multiple zone heating and cooling systems. It is
optional on plans.
MECHANICAL HVAC ACCEPTANCE FORMS (check box for required forms)
Designer:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for HVAC systems. The designer is required to check the applicable boxes for all
acceptance tests that apply and list all equipment that requires an acceptance test. All equipment of the some type that requires a test, list.the equipment description and the number of systems.
Installing Contractor:
The contractor who installed the equipment is responsible to either conduct the acceptance test them self or have a qualified.entity run the test for them. If more than one person has
responsibility for the acceptance testing, each person shall sign and submit the Certificate of Acceptance applicable to the portion of the construction or installation for which they are responsible.
Enforcement Agency:
Plancheck — The NRCC-MCH-01-E form is not considered a completed form and is not to be accepted by the building department unless the correct boxes are checked.
Inspector - Before occupancy permit is granted all newly installed process systems must be tested to ensure proper operations.
Test Description
MCH -02A
MCH -03A
MCH -04A
MCH -05A
MCH -06A
MCH -07A
MCH -08A
MCH -09A
MCH -10A
MCH -11A
Equipment # of
Outdoor
Single Zone
Air
Economizer
Demand
Supply Fan
Valve Leakage
Supply Water
Hydronic
Automatic
Requiring Testing units
Air
Unitary
Distribution
Controls
Control
VAV
Test
Temp. Reset
System
Demand Shed
or Verification
Ducts
Ventilation
Variable Flow
Control
(DCV)
Control
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014
STATE OF CALIFORNIA
MECHANICAL SYSTEMS
CEC-NRCC-MCH-01-E Revised 06/14
CERTIFICATE OF COMPLIANCE
Mechanical Systems
PmjectName: Old Town Artisan Studio
- a
` CALIFORNIA ENERGY COMMISSION
N RCC -MCH -01-E
(Page 2 of 3)
Date Prepared: 3/29/2015 -
MECHANICAL HVAC ACCEPTANCE FORMS (check box for required forms)
Designer:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for HVAC systems.
The designer is required to check the applicable boxes for all .
acceptance tests that apply and list all equipment that requires an acceptance test. All equipment of the same type that requires a test, list the equipment description and the number of systems.
Installing Contractor:
The contractor who installed the equipment is responsible to either conduct the acceptance test them self or have a qualified
entity run the test for them. If more than one person
has
responsibility for the acceptance testing, each person shall sign and submit the Certificate of Acceptance applicable to the portion of the construction or installation for which
they are responsible.
The following tests require a
Enforcement Agency:
Plancheck — The NRCC-MCH-01-E form is not considered a completed form and is not to be accepted by the building department unless the correct boxes are checked.
Inspector - Before occupancy permit is granted all newly installed process systems must be tested to ensure proper operations.
Test Description
MCH -12A
MCH -13A
MCH -14A
MCH -15A
MCH -16A
MCH -17A
MCH -18A
Equipment N of
Fault Detection &
Automatic Fault
Distributed Energy
Thermal Energy
Supply Air
Condenser Water
ECMS
Requiring Testing units
Diagnostics for DX
Detection &
Storage DX AC
Storage (TES)
Temperature Reset
Reset Controls
or Verification -
Units
Diagnostics for Air &
Systems
Systems
Controls
Zone
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
O
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
-
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑.
❑
❑
❑
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014
STATE OF CALIFORNIA
MECHANICAL SYSTEMS
CEC-NRCC-MCH-01-E Revised 06114
CERTIFICATE OF COMPLIANCE '
Mechanical Systems
Project Name: Old Town Artisan Studio
CALIFORNIA ENERGY COMMISSION
NRCC-MCH-01-E
(Page 3 of 3)
Date Prepared: 3/29/2015
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete. f '
Documentation Author Name: Gina ROS@ Documentation Author Signature: -.+ ..
Company: EQS, Inc.
Signature Date: 3/29/2015
Address: P.O. BOX 170
CEA/ HERS Certification Identification (if applicable): ,
City/state/zip: Gold HIII , OR 97525
Phone: 760-218-3350
RESPONSIBLE PERSON'S DECLARATION STATEMENT -
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible
designer). - . • =
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance
conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance' are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
S. 1 will ensure that a completed signed copy of this Certificate of Compliance`shall be made available with the building permit(s) issued for the building, and made available to the enforcement
agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the
building owner at occupancy.
Responsible DesignerpW �N
Responsible Designer Signa e:
Company: ^ ^
►—\
Date Signed: nom,
j 3 o
Address:
License:
City/State/Zip: -
Phone: -
STATE OF CALIFORNIA
HVAC SYSTEM REQUIREMENTS I e
CEC-NRCC-MCH-02-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION -4W'
CERTIFICATE OF COMPLIANCE NRCC-MCH-02-E
HVAC Dry System Requirements (Page 1 of 3)
Project Name: Old Town Artisan Studio Date Prepared: 3/29/2015
Equipment Tags and System Description'
Suite
MANDATORY MEASURES
Heating Equipment Efficiency3
Cooling Equipment Efficiency3
HVAC or Heat Pump Thermostats
Furnace Standby Loss Control
Low leakage AHLIs
Ventilation
Demand Control Ventilations
Occupant Sensor Ventilation Contro16
Shutoff and Reset Controls'
Outdoor Air and Exhaust Damper Control
Isolation Zones
Automatic Demand Shed Controls
Economizer FDD
Duct Insulation
PRESCRIPTIVE MEASURES
T-24 Sections Reference to the Requirements in the Contract Documents2
110.1 or 110.2(a)
110.1 or 110.2(a)
110.2(b), 110.2(c)
110.2(d)
110.2(f)
120.1(b)
120.1(c)4
120.1(c)5, 120.2(e)3
120.2(e)
120.2(f)
120.2(g)
120.2(h)
120.2(i)
120.4
Equipment is sized in conformance with 140.4(a & b) y
140.4(a&b)
Supply Fan Pressure Control 140.4(c)
Simultaneous Heat/Cools 140.4(d)
Economizer 140.4(e)
Heat and Cool Air Supply Reset 140.4(f)
Electric Resistance Heating9 140.4(g)
Duct Leakage Sealing and Testing. 10 140.4(1)
Notes:
1. Provide equipment tags (e.g. AHU 1 to 10) and system description (e.g. Single Dud VAV reheat) as appropriate. Multiple units
with common requirements can be grouped together. '
2. Provide references to plans (i.e. Drawing Sheet Numbers) and/or specifications (including Section name/number and relevant
paragraphs) where each requirement is specified. Enter"N/A" if the requirement is not applicable to this system.
3. The referenced plans and specifications must include all of the following information: equipment tag, equipment nominal.
capacity, Title 24 minimum efficiency requirements, and actual rated equipment efficiencies. Where multiple efficiency
requirements are applicable (e.g. full- and part -load) include all. Where appliance standards apply (110.1), identify where
equipment is required to be listed per Title 201601 et seq.
4. Identify where the ventilation requirements are documented for each central HVAC system. Include references to both central
unit schedules and sequences of operation. If one or more space is naturally ventilated identify where this is documented in the
plans and specifications. Multiple zone central air systems must also provide a MCH -03-E form.
5. If one or more space has demand controlled ventilation identify where it is specified including the sensor specifications and the
sequence of operation.
6. If one or more space has occupant sensor ventilation control identify where it is specified including the sensor specifications and
the sequence of operation
7. If the system is DDC identify the sequences for the system start/stop, optimal start setback (if required) and setup (if required).
For all systems identify the specification for the thermostats and time clocks (if applicable).
8. Identify where the heating, cooling and deadband airflows are scheduled for this system. Include a reference to the
specification of the zone controls. Provide a MCH -03-E form.
9. Enter N/A if there is no electric heating. If the system has electric heating indicate which exception to 140.4(g) applies.
10. If duct leakage sealing and testing is required, a MCH -04-A form must be submitted.
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014
STATE OF CALIFORNIA
HVAC SYSTEM REQUIREMENTS
CEC-NRCC-MCH-02-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE, NRCC-MCH-02-E
HVAC Wet System Requirements (Page 3 of 3)
Project Name: Old Town Artisan Studio Date . Prepared: 3/29/2015
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT -
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:
Gina Rose
Company: EQS, Inc.
Signature Date:
3/29/2015
Address:
P.O. Box 170
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Gold Hill, OR 97525
Phone:
760-218-3350
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design
identified on this Certificate of Compliance (responsible designer).
3. The energy features and performance specifications, materials, components, and manufactured devices for the building desigri or system
design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information
provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement
agency for approval with this building permit application.
5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this
Certificate of Compliance is required to be included with the documentation the builder provides to the building -owner at occupancy.
Responsible Design r
Responsible Depgrrer%Signature:
Company: •
r W7 J J -u LQ
Date Signed:
S 1 S
Address:
License:
City/State/Zip:
Phone:
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance
June 2014
STATE OF CALIFORNIA
MECHANICAL VENTILATION' AND REHEAT
CEC-NRCC-MCH-03-E Revised 06/14
CERTIFICATE OF COMPLIANCE
Mechanical Ventilation & Reheat
Project Name: Old Town Artisan Studio .
Date Prepared: W29/2015
:NERGY COMMISSION'
NRCC-MCH-03-E
(Page 2 of 2)
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1.. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:
Gina Rose
Company: EQ$, Inc. Signature Date: 3/29/2015 '
Address:
- P.O. Box 170
CEA/ HERS Certification Identification (if applicable):
r
city/stat1. e/zip: Gold Hill, OR 97525
Phone: 760-218-3350
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. lam eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible
designer).
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design.identified on this Certificate of Compliance
conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. .
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. 1 will ensure that a completed Signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement ,
agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the
building owner at occupancy.
Responsible DA Name:
Responsible D rSignature: -
' Company: -
Date Signe r; F(
J! r -
Address:
License:
City/State/Zip:
Phone: '
STATE OF CALIFORNIA
',REQUIRED ACCEPTANCE TESTS ,
MECHANICAL COMPLIANCE FORMS & WORKSHEETS (indicate if worksheet is included) " r
For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, refer to the 2013 Nonresidential Manual Note: The. Enforcement Agency may t
require all forms to be incorporated onto the building plans. Forms NRCC-MCH-04-E and NRCC-MECH-05-E are alternative forms to NRCC-MCH-01-E, NRCC-MCH-02-E and NRCC-
MCH-03-E for projects using only single zone packaged HVAC systems.
YES
NO
Form.
Title -
~/
NRCC-MCH-04-E (1 of 2)'
Certificate of Compliance. Required on.plans when used.
NRCC-MCH-04-E (2 of 2) ,
Mechanical Acceptance Tests. Required on plans when used.
NRCC-MCH-05-E (1 of 2)
HVAC Prescriptive Requirements. It is required on plans when used.
NRCC-MCH-05-E (2 of 2)
-
Mechanical SWH Equipment Summary is required for all submittals with service water heating, pools or spas. it is
required on plans where applicable.
STATE OF CALIFORNIA
REQUIRED ACCEPTANCE TESTS
:EC-NRCC-MCH-04-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-04-E
Required Acceptance Tests (Page 2 of 3)
``oiectName: Old Town Artisan Studio Date Prepared: 3/29/2015
Designer:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the
applicable boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment
description and the number of systems. The NA number designates the Section in the Appendix of the Nonresidential Reference Appendices Manual that describes the test.
Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately.
Enforcement Agency:
Systems Acceptance. Before occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated
for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance.
Systems Acceptance. Before occupancy permit is granted. All newly installed HVAC equipment must be tested using the Acceptance Requirements..
The NRCC-MCH-04-E form is not considered a completed form and is not to be accepted by the building department unless the correct boxes are checked. The equipment
requiring testing, person performing the test (Example: HVAC installer, TAB contractor, controls contractor, PE in charge of project) and what Acceptance test must be
conducted. The following checked -off forms are required for ALL newly installed and replaced.equipment. In addition a Certificate of Acceptance forms shall be submitted to
the building department that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of Section 10-103(b)
and Title 24 Part 6. The building inspector must receive the properly filled out and signed forms before the building can receive final occupancy.
Test Description
MCH -02-A
MCH -03-A
MCH -04-A
MCH -05-A
MCH -06-A
MCH -07-A
MCH -11-A
MCH -12-A
MCH -14-A
MCH -18-A
Test Performed By:
Equipment # of
Outdoor ,
Single Zone
Air
Economizer
Demand
Supply
Automatic
FDD for
Distribute
Energy
Requiring units
Air
Unitary
Distribution
Controls
Control
Fan VAV
Demand
Packaged
d Energy
Managem
Testing or
Duds
Ventilation
Shed
DX Units
Storage
ent
Verification
(DCV)
Control
DX AC
Control
Systems
System
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014
STATE OF CALIFORNIA
REQUIRED ACCEPTANCE TESTS
CEC-NRCC-MCH-04-E Revised 06114 J CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-04-E
Required Acceptance Tests (Page 3 of 3)
Project Name: Old Town Artisan Studio Date Prepared: 3/29/2015
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete. /^
Documentation Author Name: Documentation Author Signature: ""' /
Gina Rose
Company: EQS,* Inc. Signature Date: 3/29/2015
Address: P.O. BOX 170
CEA/ HERS Certification Identification (if applicable):
City/State/Zip: Gold Hill, OR 97525.
Phone: 760-218-3350
RESPONSIBLE PERSON'S DECLARATION STATEMENT -
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible
designer).
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance
conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 1
5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building perm' it(s) issued for the building, and made available to the enforcement
agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the
building owner at occupancy. {
Responsible Designer Name:
Responsible Designer Signature:
Company:
Date Signed: -
Address:
License:
City/State/Zip:
Phone:
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance
STATE OF CALIFORNIA
WATER HEATING SYSTEM GENERAL INFORMATION
CERTIFICATE OF COMPLIANCE NRCC-PLB-01-E
Water Heating System General Information (Page 1 of 2)
Project Name: Old Town Artisan Studio Date Prepared: 312912015
A. GENERAL INFORMATION/SYSTEM INFORMATION
For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, refer to the 2013 Nonresidential Manual
Note: The Enforcement Agency may require all forms to be incorporated onto the building plans.
1.
Water Heater System Name:
A O Smith Water Products ECT -30
2.
Water Heater System Configuration:
Non -Central
3.
Water Heater System Type:
1
4.
Building Type:
0.98
5.
Total Number of Water Heaters in Systems:
1
6.
Central DHW Distribution Type:
n/a
7.
Dwelling Unit DHW Distribution Type:
Standard
B. WATER HEATER INFORMATION
Each water heater type requires a separate form.
For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, refer to the 2013 Nonresidential Manual
Note: The Enforcement Agency may require all forms to be incorporated onto the building plans.
1.
Water Heater Type:
Small Storage Electric
2.
Fuel Type
Electric Res
3.
Number of Identical Water Heaters:
1
4.
Efficiency:
0.98
5.
1 Required Minimum Efficiency:
0.98
6.
Standby loss percent or Standby loss total:
0.000
7.
Rated Input
15,359
8.
Pilot Energy:
Certificate of Installation, required on HERS verified central systems in high-rise
residential, hotel/motel application.
9.'
Water Heater Tank Storage Volume:
10
10.
Exterior Insulation On Water Heater:
0
11.
Volume of Supplemental Storage:
12.
Internal Insulation on Supplemental Storage:
13.
Exterior Insulation on Supplemental Storage:
PLUMBING COMPLIANCE FORMS & WORKSHEETS (check box if worksheet is included)
For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, refer to the 2013 Nonresidential Manual
Note: The Enforcement Agency may require all forms to be incorporated onto the building plans.
YES
NO
Form/Worksheet#
Title
®
❑
NRCC-PLB-01-E
Certificate of Compliance, Declaration. Required on plans for all submittals.
❑
❑
NRCI-PLB-01-E
Certificate of Installation. Required on plans for all submittals.
❑
❑
NRCI-PLB-02-E
Certificate of Installation, required on central systems in high-rise residential,
hotel/motel application. t
❑
❑
NRCI-PLB-03-E
Certificate of Installation, required on single dwelling unit systems in high-rise
residential, hotel/motel application.
❑
❑
NRCI PLB-21-H
Certificate of Installation, required on HERS verified central systems in high-rise
residential, hotel/motel application.
LJ
❑
NRCI-PLB-22-H
Certificate of Installation, required on HERS verified single dwelling unit systems in
high-rise residential, hotel/motel application.
�OO
NRCI-STH-01-E
Certificate of Installation, required on any solar water heating
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014
STATE OF CALIFORNIA '
WATER HEATING SYSTEM GENERAL INFORMATION
CEC-NRCC-PL&01-E Revised 06/14
CERTIFICATE OF COMPLIANCE
Water Heating System General Information
Project Name: Old Town Artisan Studio '
y
N RCC -P LB -01-E
(Page 2 of 2)
Date Prepared: 3/29/2015
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. ' I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:
Gina Rose
Company: EQS, Inc. Signature Date: 3/29/2015,
Address: P.O. BOX 170 .
CEA/ HERS Certification Identification (if applicable):
City/State/Zip: Gold Hill, OR 97525
Phone: 760-218-3350
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design
identified on this Certificate of Compliance (responsible designer).
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or
system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the
California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the
information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to
the enforcement agency for approval with this building permit application.
5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all.applicable inspections. I understand that a completed
signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building
owner at occupancy.
Responsible i ner Name:
1� iVIJ
Respo a signer Signat
Company: %� /
"ir✓ �-7
Date Signed:lnl-a
Address:
License:
City/State/Zip:
Phone:
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance
1 ' June 2014
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Old Town Artisan Studio
Date
3/29/2015
System Name
Suite
Floor Area
2,480
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total ROOM Loads 5,154
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 1,145
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 55,000
77,292
15,719 326
24,224
Total Output Btuh 110,000
0
Output Btuh/ ft 44.4
3,865
1,211
Cooling System
0
0
Output perSystem 57,000
45,183
12,238 1,145
53,251
Total Output Btuh 114,000.
0
3,865
1 130,204
27,958
0
Total output ons 9.5
1,211
Total Output Btuh/s ft 46.0
Total Output s ft/Ton 261.1
179,897
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
4,000
Existing Day and Night
91,644
15,996
68,703
Airflow cfm/s ft
1.61
68,703
Jan 1 AM
Airflow cfm/Ton 421.1
Outside Air°/, 28.6%
Total Adjusted System Output 1 91,644
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
15,996
Aug 3 PM
Outside Air (cfm/ft 0.46
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
10t Outside Air
1,145 cfm
70 OF
57 OF 140 OF 140 OF
Heating Coil Supply Fan
4,000 cfm
140 o F
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air Ar
1,145 cfm
75/64°F
86/69°F 59/58°F 59/58°F
c! 4' ..
Cooling Coil Supply Fan
4,000 cfm
'
a
60 / 58 OF
59.2 % 1. ROOM'
r
74/64°F
EneigyPro 6.4 by EnergySoft
User Number.' 5862 RunCode: 2015-03-29709:08:19
ID:
Page 32 of 32