Loading...
BCOM2017-000378-495 CALLE TAMPICO Q.�i D LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BCOM2017-0003 Property Address: 78140 CALLE.TAM Pic D APN: 770020023 Application Description: COMM T. I. Property Zoning: FEB 2 12017 Application Valuation: "$150,000.00 CITY OF LA QUINTA Applicant: DESIGN AND DEVELOPMENT DEPARTMENT GABRIEL LUJAN LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business a rofessions Code, and my License is in full force and effect. License Class: B License No.: 951607 Date: -L,% , 2 - Contractor: OWNER -BUILDER C TION I hereby affirm under penalty of perjury th m exempt from the Contractor's State License Law for the following reason (Sec: 31.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500):: (� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his'or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (___) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and'who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued.(Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 . FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/21/2017 Owner:- DUNCAN SMITH 17 ARDENDALE CT ALAMO, CA 92253 Contractor: STATEWIDE SERVICES INC DBA STATEWIDE CON 73-700•DINAH SHORE DR STE 405 PALM DESERT, CA 92211 (760)699-5434 Llc. No.: 951607 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: BENCHMARK INSURANCE COMPANY Policy Number: CST5067723 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become su "ect to the workers' compensation provisions of Section 3700 of the LaborCod hall forthwith comply with those provisions. Dat\ `/ �.� Applicant: WARNING: FAILURE TO SECURE WORKER 0 NSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO �L PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT:' Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf.this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta,'its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of, this permit. 2. Any permit issued as a.result of this application'becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application. and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to build' g construction, and hereby authorize representatives of this city to enter upon t . above-mentioned property for inspection purposes. Date: __ 1 t I r�ignaturee'(Applicant-or,Agent) DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $6.00 . Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $6.00 DESCRIPTION ACCOUNT QTY . AMOUNT Credit Card Fee 101-0000-43505 0 $36.46 Total Paid for Credit Card Fee: $36.46 DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, EA ADDITION 2,000SF 101-0000-42403 0 $228.00 DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, EA ADDITION 2,000SF, PC . 101-0000-42600 0 $60.78 DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, FIRST 2,000SF 101-0000-42403 0 $114.00 DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, FIRST 2,000SF, PC 101-0000-42600 0 $88.16 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $490.94 DESCRIPTION ACCOUNT QTY AMOUNT APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $5.07 Total Paid for MECHANICAL: $17.74 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $38.01 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $38.01 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $7.60 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0. $12.67 Total Paid for PLUMBING FEES: $121.63 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $638.40 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $510.72 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 100 SF 101-0000-42400 0 $51.68 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $141:36 Total Paid for REMODEL: $1,342.16 DESCRIPTION_ , ACCOUNT QTY AMOUNT SMI - COMMERCIAL 101-0000-20308 0 $42.00 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $42.00 DESCRIPTION ACCOUNT QTY ' AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611. 0 $5.00 1 i Qin nCcity of La quinta. building 8T Safety Division Permit # o3 _ 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-701,2 Building Permit Application and Tracking Sheet Project Address: ` O . C-ft1 \ e wner's Name: . ?_—XC in F A. P. Number: Address: ll e 4 FAt co Legal Description: City, ST, Zip: L&1 �. ontra r: C ct 0 • Telephone: Address: Project Description: ' City, ST, Zip: Telephone: ' e h o . P e' lLdo. State Lic. # : City Lie. #; Arch.,`Engr., Signe . QDQ-�jyt Address:G V./ t '�G'` ILM City., ST, Zip: 0.`µ _ a'� 1 ` S'��• S$ S1hW S1� 5 an: Occupancy: ConTelephone:—I�DS fractt n TYPe: cY State Lie. 4: Add n ?iter Demo oProJectPe circle one � N w tY Name of Contact Person: �tG Sq. Ft.: t'b �orl #Stories: 2 #Units: Telephone # of Contact Person: ' S164 SrEstimated Value of Project: On 0 APPLICANT: DO NOT WRITE BELOW THIS LINE to Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item . , Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cafes. Called Contact Person Plan Check Balance • Title 24 Cafes. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°° Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing - Grant Deed Plans picked up II.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Rcyiew, ready for corrections/issue Devcloper.Impact Fee Planning Approval Called Contact Person A.I.P.P. P•ub. Wks. Appr Date of permit issue School Fees, I Total Permit Fees officG"tco BUILDING ENERGY,ANALYSIS REPORT. a;. PROJECT: Tenant Improvement . 78-140 Calle Tampico ; La Quinta, CA 92253 Project Designer: Gabe Lujan Panorama . Palm Desert, CA 92236 ; (760) 578-8545 CITY OF LA QUINTA Report Prepared yBUILDING & SAFETY DEPT. Jon Scott , APPR VED. FOR CON RUCTION `g• Scott Design and Title 4, Inc, 74-818 Velie Way, T8 '21►s� Palm Desert, CA 9 (760) 702-540.6 RECEIVED, JAN 10 2017 CITY OF LA QUINTA COMMUNITY DEVELOPMENT Job Number: Date: RECEIVED 12/14/2016 FEB 0 7 2017 CITY OF LA QUINTA The EnergyPro computer program has been used to perform the calculations summarized in this complianceGPMMUI#7360EMSLQWENTnd is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. `• This program developed by EriergySoft,. LLC —.www.energysoft.com. �`* ? EnergyPro 6.7 by EnergySoft User Number: 6712 ID: i 0 0 - project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 1 of 17 >roject Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 ' ompliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xml A. PROJECT GENERAL INFORMATION 1. Project Location (city) La Quinta 7. # of dwelling units 0 2. CA Zip Code 92253 8. Standards Version Compliance2015 3. Climate Zone 15 9. Compliance Software (version) EnergyPro 6.7 4. Total Conditioned Floor Area 10,492 ft2 10. Building Orientation (deg) (S) 180 deg S. Total Unconditioned Floor Area 0 ft2 11. Permitted Scope of Work ExistingAddition 6. # of Stories (Habitable Above Grade) 2 12 Building Type(s) Nonresidential B. COMPLIANCE RESULTS FOR PERFORMANCE COMPONENTS (Annual TDV Energy Use, kBtu/ft 2 -yr) § 140.1 BUILDING COMPLIES 1. Energy Component 2. Standard Design (TDV) 3. Proposed Design (TDV) 4. Compliance Margin (TDV) S. Percent Better than Standard Space Heating 12.7 4.8 7.9 62.2% Space Cooling 271.4 208.3 63.1 23.2% Indoor Fans 68.8 98.6 -29.8 -43.3% Heat Rejection Pumps & Misc. 0.4 - 0.4 Domestic Hot Water Indoor Lighting 83.9 83.9 0.0% COMPLIANCE TOTAL 437.2 395.6 41.6 9.5% Receptacle 91.3 91.3 0.0 0.0% Process Process Ltg TOTAL 528.5 486.9 41.6 7.9% CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 2 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xml C. PRIORITY PLAN CHECK/ INSPECTION ITEMS (in order of highest to lowest TDV energy savings) ' 1st Space Cooling: Check envelope and mechanical Compliance Margin By Energy Component (from Table B column 4) Space Cooling f I Space Heating Pumps & Misc. j 2nd Space Heating: Check envelope and mechanical 3rd Pumps & Misc.: Check mechanical 4th Heat Rejection: Check envelope and mechanical Heat Rejection 5th Domestic Hot Water: Check mechanical Domestic Hot Water ' Indoor Lighting 6th Indoor Lighting: Check lighting Indoor Fans 7th Indoor Fans: Check envelope and mechanical _ - EnecgylCredit� ;��Pen�alty D. EXCEPTIONAL CONDITIONS The building does not include service water heating. Verify that service water heating is not required and is not included in the design. E. HERS VERIFICATION This Section Does Not Apply F. ADDITIONAL REMARKS None Provided CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 3 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xm1 G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY Identify which building components use the performance or prescriptive path for compliance. "NA"= not in project For components that utilize the performance path, indicate the sheet number that includes mandatory notes on plans. Building Component Compliance Path Compliance Forms (required forsubmittal) Location of Mandatory Notes on Plans Envelope ❑ Performance NRCC-PRF-ENV-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-ENV-01 / 02 / 03 / 04 / 05 / 06-E ® NA Mechanical ® Performance NRCC-PRF-MCH-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-MCH-01 / 02 / 03 / 04 / 05 / 06 / 07-E ❑ NA Domestic Hot Water ❑ Performance NRCC-PRF-PLB-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-PLB-01-E ® NA Lighting (Indoor Conditioned) ® Performance NRCC-PRF-LTI-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-LTI-01 / 02 / 03 / 04 / 05-E ❑ NA Covered Process: Commercial Kitchens ❑ Performance S2 (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC PRC O1/ 03-E ® NA Covered Process: Computer Rooms ❑ Performance S3 (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-PRC-01/ 04-E ® NA Covered Process: Laboratory Exhaust ❑ Performance S4 (section of the NRCC-PRF-01-E) ElPrescriptive NRCC-PRC O1/ 09-E ® NA CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 4 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xml G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY The following building components are only eligible for prescriptive compliance. Indicate which ore The following building components may have mandatory requirements per Part 6. Indicate relevant to the project. which are relevant to the project. Yes NA Prescriptive Requirement Compliance Forms Yes NA Mandatory Requirement Compliance Forms Lighting (Indoor Commissioning: §120.8 ❑ ® NRCC-LTI-01 / 02 / 03 / 04 / 05-E E]® Simple Systems NRCC-CXR-01 / 02 / 03 / 05-E Unconditioned) §140.6 . ❑ - ® "Complex Systems NRCC-CXR-01 / 02 / 04 / 05-E ❑ ® Lighting (Outdoor) §14 NRCC-LTO-01 / 02 / 03-E ® ❑ Electrical: §130.5 NRCC-ELC-01-E ❑ ® Lighting (Sign) §140.8 NRCC-LTS-01-E ❑ ® Solar Ready: §110.10 NRCC-SRA-01 / 02-E Covered Process: §120.6 NRCC-PRC-01-E ❑ . ® Parking Garage NRCC-PRC-02-E Solar Thermal Water E]® Commercial Refrigeration NRCC-PRC-05-E VEl Heating: §140.5 ❑ ® Warehouse Refrigeration NRCC-PRC-06/07/08-E 4/1 ❑ - ® Compressed Air NRCC-PRC-10-E ❑ ® Process Boilers NRCC-PRC-11-E CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 - 0 0 0 Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 5 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xml H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCI/NRCA/NRCV) — Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required for submittal) Pass Fail Envelope ❑ NRCI-ENV-01-E - For all buildings ❑ ❑ ❑ NRCA-ENV-02-F- NFRC label verification for fenestration ❑ ❑ Mechanical ® NRCI-MCH-01-E - For all buildings with Mechanical Systems ❑ ❑ ® NRCA-MCH-02-A- Outdoor Air ❑ ❑ ® NRCA-MCH-03-A—Constant Volume Single Zone HVAC ❑ ❑ ❑ NRCA-MCH-04-H- Air Distribution Duct Leakage ❑ ❑ ❑ NRCA-MCH-05-A- Air Economizer Controls ❑ ❑ ❑ NRCA-MCH-06-A- Demand Control Ventilation ❑ ❑ ❑ NRCA-MCH-07-A—Supply Fan Variable Flow Controls ❑ ❑ ❑ NRCA-MCH-08-A- Valve Leakage Test ❑ ❑ ❑ NRCA-MCH-09-A — Supply Water Temp Reset Controls ❑ ❑ ❑ NRCA-MCH-10-A- Hydronic System Variable Flow Controls ❑ ❑ ❑ NRCA-MCH-1I-A—Auto Demand Shed Controls ❑ ❑ ❑ NRCA-MCH-12-A- Packaged Direct Expansion Units ❑ ❑ ❑ NRCA-MCH-13-A- Air Handling Units and Zone Terminal Units ❑ ❑ ❑ NRCA-MCH-14-A- Distributed Energy Storage ❑ ❑ ❑ NRCA-MCH-15-A—Thermal Energy Storage ❑ ❑ ❑ NRCA-MCH-16-A- Supply Air Temp Reset Controls ❑ ❑ ❑ NRCA-MCH-17-A— Condensate Water Temp Reset Controls ❑ ❑ ❑ NRCA-MCH-18-A- Energy Management Controls Systems ❑ ❑ ❑ NRCV-MCH-04-H- Duct Leakage Test ❑ ❑ CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 • 0 0 � Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 6 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xml H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCI/NRCA/NRCV) — Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required for submittal) Pass Fail Plumbing ❑ NRCI-PLB-01-E - For all buildings with Plumbing Systems ❑ ❑ ❑ NRCI-PLB-02-E - required on central systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCI-PLB-03-E - Single dwelling unit systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCI-PLB-21-E - HERS verified central systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCI-PLB-22-E - HERS verified single dwelling unit systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCV-PLB-21-H- HERS verified central systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCV-PLB-22-H - HERS verified single dwelling unit systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCI-STH-01-E - Any solar water heating ❑ ❑ Indoor Lighting ® NRCI-LTI-01-E - For all buildings ❑ ❑ ❑ NRCI-LTI-02-E - Lighting control system, or for an Energy Management Control System (EMCS) ❑ ❑ ❑ NRCI-LTI-03-E - Line -voltage track lighting integral current limiter, or for a supplementary overcurrent protection panel used to energize only line -voltage track lighting ❑ ❑ ❑ NRCI-LTI-04-E - Two interlocked systems serving an auditorium, a convention center, a conference room, or a theater ❑ ❑ ❑ NRCI-LTI-05-E -Lighting Control Credit Power Adjustment Factor (PAF) ❑ ❑ ❑ NRCI-LTI-06-E - Additional wattage installed in a video conferencing studio ❑ ❑ ❑ NRCA-LTI-02-A - Occupancy sensors and automatic time switch controls. ❑ ❑ ❑ NRCA-LTI-03-A - Automatic daylighting controls ❑ ❑ ❑ NRCA-LTI-04-A - Demand responsive lighting controls ❑ ❑ Outdoor Lighting ❑ NRCI-LTO-01-E— Outdoor Lighting ❑ ❑ ❑ NRCI-LTO-02-E- EMCS Lighting Control System ❑ ❑ ❑ NRCA-LTO-02-A -Outdoor Lighting Control ❑ ❑ Sign Lighting ❑ N RCI-LTS-01-E —Sign Lighting ❑ ❑ Electrical ® NRCI-ELC-01-E - Electrical Power Distribution ❑ ❑ Photovoltaic ❑ NRCI-SPV-01-E Photovoltaic Systems ❑ ❑ CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 • Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 7 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xml H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCI/NRCA/NRCV) — Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required for submittal) Pass Fail Covered Process ❑ NRCI-PRC-01-E Refrigerated Warehouse ❑ ❑ ❑ NRCA-PRC-01-F- Compressed Air Systems ❑ ❑ ❑ NRCA-PRC-02-F- Kitchen Exhaust ❑ ❑ ❑ NRCA-PRC-03-F- Garage Exhaust ❑ ❑ ❑ NRCA-PRC-04-F- Refrigerated Warehouse- Evaporator Fan Motor Controls ❑ ❑ ❑ NRCA-PRC-05-F- Refrigerated Warehouse- Evaporative Condenser Controls • ❑ ❑ ❑ NRCA-PRC-06-F- Refrigerated Warehouse- Air Cooled Condenser Controls ❑ ❑ ❑ NRCA-PRC-07F- Refrigerated Warehouse- Variable Speed Compressor ❑ ❑ ❑ NRCA-PRC-08-F- Electrical Resistance Underslab Heating System ❑ ❑ I. ENVELOPE GENERAL INFORMATION (See NRCC-PRF-ENV-DETAILS for more information) 1. Total Conditioned Floor Area 10,492 ft2 5. Number of Floors Above Grade 2 Confirmed 2. Total Unconditioned Floor Area 0 ft2 6. Number of Floors Below Grade 0 � d N T y = 3. Addition Conditioned Floor Area 0 ft2 4. Addition Unconditioned Floor Area 0 ft2 7. Opaque Surfaces & Orientation 8. Total Gross Surface Area 9. Total Fenestration Area 10. Window to Wall Ratio North Wall 1,952 ft2 280 ft2 14.3% ❑ ❑ East Wall 1,360 ft2 168 ft2 12.4% ❑ ❑ South Wall 1,952 ft2 364 ft2 18.6% ❑ ❑ West Wall 1,360 ft2 72 ft2 05.3% ❑ ❑ Total 6,624 ft2 884 ft2 13.3% ❑ ❑ Roof 1,518 ft2 0 ft2 00.0% ❑ ❑ CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 • Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 8 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xml J. FENESTRATION ASSEMBLY SUMMARY § 110.6 Confirmed 1. 2. 3. 4. 5. 6. 7. 8. 9. Surface Name Surface Type Z Area (ft) Framing Type Cavity R -Value Continuous R -Value U -Factor / F -Factor / C -Factor iv v. a R-30 Roof Attic9 Roof Fenestration Assembly Name / Metal 30 NA U -Factor: 0.070 Overall Overall Overall d VT H °' Wood Fenestration Type Certification Method 1 Assembly Method Area ft2 ❑ ❑ R-30 Floor no Crawlspace54 ExteriorFloor 10492 Wood Tag or I.D. NA U -Factor: 0.033 E ❑❑ U-factor SHGC VT N Wood 13 Exist. Single Glazed Vertical Fenestration DefaultPerformance Manufactured 884 1.19 0.83 1 0.77 E ❑ ❑ 'Newly installed fenestration shall have a certified NFRC Label Certificate or use the CEC default tables found in Toble 110.6-A and Table 110.6-8. Center of Glass (COG) values are for the glass -only, determined by the manufacturer, and are shown for ease of verification. Site -built fenestration values are calculated per Nonresidential Appendix NA6 and are used in the analysis. z Status: N - New, A -Altered, E - Existing Taking compliance credit for fenestration shading devices? (if "Yes", see NRCC-PRF-ENV-DETAILS for more information) K. OPAQUE SURFACE ASSEMBLY SUMMARY § 120.7/ § 140.3 Confirmed 1. 2. 3. 4. 5. 6. 7. 8. Surface Name Surface Type Z Area (ft) Framing Type Cavity R -Value Continuous R -Value U -Factor / F -Factor / C -Factor iv v. a R-30 Roof Attic9 Roof 1518 Metal 30 NA U -Factor: 0.070 E ❑ ❑ R-19 Wallll ExteriorWall 6624 Wood 19 NA U -Factor: 0.072 E ❑ ❑ R-30 Floor no Crawlspace54 ExteriorFloor 10492 Wood 30 NA U -Factor: 0.033 E ❑❑ NA R-0 interior surface56 InteriorWall 825 Wood 13 NA U -Factor: 0.095 E ❑ ❑ `Status: N- New A - Altered, E -Existing L. ROOFING PRODUCT SUMMARY § 140.3 Confirmed 1. 2. 3. 4. S. 6. 7. Aged Solar Thermal Cool Roof V N v Product Type Product >_251b ft1 SRI CRRC Product 10 Number - Reflectance Emittance Credit R-30 Roof Attic9 No 0.08 0.75 NA No NA ❑ ❑ CA Building Energy Efflclencv Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 • 0 Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 9 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xmi M. HVAC SYSTEM SUMMARY (see NRCC-PRF-MCH-DETAILS for more information) I § 110.1 / § 110.2 Dry System Equipment' (Fan & Economizer info included below in Table N) Confirmed 1. 2. 3. 4. S. 6. 7., 8. 9. 10. 11. 23. 24. Air System Type Total Heating Supp Heat Supp Heat Total Cooling Efficiency cY Acceptance Testing a, .o a d c Equip Name Equip Type 3 (Simple or Qty Output Source (Y/N) Output Output (kBtu/h) Required? (Y/N) N N Qty GPM HP Complex 4) N (kBtu/h) CFM (kBtuh) (kBtu/h) s Control CFM HP Cooling Heating HVAC -11 SZHP (Split3Phase) Simple 18 42 No 0 42 SEER -15.0 HSPF-8.0 Yes A ❑ ❑ Wet System Equipment 2 Pumps Confirmed Confirmed 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. Air M Rated Capacity Tank Economizer Type N VSD L � N T °' Equip Name Equip Type Qty Vol (gal) (kBtu/h) Efficiency Standby Loss Ext. R Qty GPM HP (Y/N) N CFM CFM HP BHP (inch Control CFM HP BHP Value Control a 'Dry System Equipment includes furnaces, air handling units, heat pumps, etc. Z Wet System Equipment includes boilers, chillers, cooling towers, water heaters, etc. 3 Simple Systems must complete NRCC-CXR-03-E commissioning design review farm 4 Complex Systems must complete NRCC-CXR-04-E commissioning design review form S A summary of which acceptance tests are applicable is provided in NRCC-PRF-MCH-DETAILS 6 Status: N - New, A - Altered, E - Existing Discrepancy between modeled and designed equipment sizing? (if "Yes", see Table F. "Additional Remarks" for an explanation) No N. ECONOMIZER & FAN SYSTEMS SUMMARY' § 140.4 Confirmed 1. 2. 3. 4. S. Outside Supply Fan Return Fan Air M T Economizer Type N °' TSP TSP Equip Name (if present) CFM CFM HP BHP (inch Control CFM HP BHP (inch Control WC) WC) HVAC -11 291 1 1400 0.500 0.500 1.13 ConstantVolume NA NA NA NA NA NoEconomizer 1 ❑ tEl 1 Mechanical ventilation calculations and exhaust fans are included in the NRCC-PRF-MCH-DETAILS section CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 10 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-.16.xmi O. EQUIPMENT CONTROLS § 120.2 Confirmed 1. 2. 3. a -n — Equip Name Equip Type Controls No DCV Controls .. HVAC -11 SZHP No Economizer ❑ ❑ Lighting Control Credits Additional (Custom) Allowance No Supply Air Temp. Control — P. SYSTEM DISTRIBUTION SUMMARY §120.4/ § 140.4(i) This Section Does Not Apply Does the Project Include Zonal Systems? (if "Yes", see NRCC-PRF-MCH-DETAILS for system information) No Does the Project Include a Solar Hot Water System? (if "Yes", see NRCC-PRF-MCH-DETAILS for system information) No Multifamily or Hotel/ Motel Occupancy? (if "Yes", see NRCC-PRF-MCH-DETAILS for DHW system information) No k Q. INDOOR CONDITIONED LIGHTING GENERAL INFO (see NRCC-PRF-LTI-DETAILS for more info)' § 140.6 Confirmed 1. 2. 3. 4. S. .. .T 1 Occupancy Type Conditioned floor Area z Installed Lighting Power Lighting Control Credits Additional (Custom) Allowance V — (ftz) (Watts) (Watts) Area Category Footnotes Tailored Method (Watts) ❑ ❑ (Watts) Retail Merchandise Sales, 10,492 10,170 0 0 0 ❑ ❑ Wholesale Showroom Building Totals: 10,492 10,170 0 1 See Table 140.6-C d See NRCC-LTI-01-E for unconditioned spaces _ 3Lighting information for existing spaces modeled is not included in the table . CA Buildine Energy Efficign4y $tgndards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 11 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xm1 R. INDOOR CONDITIONED LIGHTING SCHEDULE (Adapted from NRCC-LTI-01-E)1 § 130.0 Luminaire Schedule (includes all permanent installed lighting in Natural Gas (therms/yr) Total Annual Baseline conditioned space, and portable lighting over 0.3 w/ftz in Installed Watts (Conditioned) Confirmed offices) 0 Complete Luminaire Description (i.e., How Wattage is Determined Name or Item Tag 3-1amp fluorescent troffer, F32T8, Watts per luminaire Total Number Luminaires Installed Watts Pass Fail CEC Default According to one dimmable electronic ballast) from NA8 §130.0(c) 41 (1) 4 ft Fluorescent 32 Yes No 9 288 ❑ ❑ 3x4led (3) 4 ft Fluorescent 54 Yes No 183 9,882 ❑ ❑ llf lighting power densities were used in the compliance model Building Departments will need to check prescriptive forms for Luminaire Schedule details. il. COVERED PROCESS SUMMARY — ENCLOSED PARKING GARAGES § 140.9 This Section Does Not Apply 52. COVERED PROCESS SUMMARY — COMMERCIAL KITCHENS § 140.9 This Section Does Not Apply 53. COVERED PROCESS SUMMARY—COMPUTER ROOMS § 140.9 This Section Does Not Apply 54. COVERED PROCESS SUMMARY — LABORATORY EXHAUSTS § 140.9 This Section Does Not Apply T. UNMET LOAD HOURS This Section Does Not Apply U. ENERGY USE SUMMARY Electric (kWh/yr) Natural Gas (therms/yr) Total Annual Baseline 186463 706.784 Total Annual Proposed 186048 0 CA Building Engrgy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 12 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xml DOCUMENTATION AUTHOR'S DECLARATION STATEMENT § 10-103 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Jon Scott Signature: Company: Scott Design and Title 24, Inc, Address: 74-818 Velie Way, STE 8 Signature Date: 12-14-16 City/State/Zip: Palm Desert CA 92260 CEA Identification (If applicable): Phone: (760) 702-5406 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am 1 licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its 2 preparation; and that I am a licensed contractor performing this work. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to 3 Business and Professions Code Sections 5537, 5538 and 6737.1. Responsible Envelope Designer Name: Gabe Lujan Signature: NOT IN SCOPE Company: Gabe Lujan Address: Panorama Date Signed: City/State/Zip: Palm Desert CA 92236 Declaration Statement Type: Phone: (760) 578-8545 Title: License #: Responsible Lighting Designer Name: Gabe Lujan Signature: Company: Gabe Lujan Address: Panorama Date Signed: City/State/Zip: Palm Desert CA 92236 Declaration Statement Type: Phone: (760) 578-8545 Title: License #: Responsible Mechanical Designer Name: Jon d. Scott Signature: Company: Scott Design and Title 24, Inc. Address: 74-818 Velie Way, STE 8 Date Signed: 12-14-16 City/State/Zip: Palm Desert CA 92260 Declaration Statement Type: Phone: (760) 702-5406 Title: License #: CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 13 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xml NRCC-PRF-ENV-DETAILS -SECTION START A. OPAQUE SURFACE ASSEMBLY DETAILS Confirmed 1. 2. 3. 4. v '^ T c Surface Name Surface Type Description of Assembly Layers Notes Asphalt shingles - 1/4 in. Vapor permeable felt - 1/8 in. R-30 Roof Attic9 Roof Plywood - 1/2 in. ❑ ❑ Air - Cavity - Wall Roof Ceiling - 4 in. or more Metal framed roof, 16in. OC, 9.2Sin., R-30 Gypsum Board - 1/2 in. Stucco - 7/8 in. R-19 Wall11 ExteriorWall Vapor permeable felt - 1/8 in. ❑ ❑ Wood framed wall, 16in. OC, 5.5in., R-19 Gypsum Board - 1/2 in. Wood framed floor, 24in. OC, 9.25in., R-30 R-30 Floor no ExteriorFloor Plywood - 1/2 in. ❑ ❑ Crawlspace54 Carpet - 3/4 in. Stucco - 7/8 in. R-0 interior surface56 InteriorWall Vapor permeable felt - 1/8 in. ❑ ❑ .Wood framed wall, 16in. OC, 3.5in., R-13 Gypsum Board - 1/2 in. B. OVERHANG DETAILS (Adapted from NRCC-ENV-02-E) rhis Section Does Not Apply C. OPAQUE DOOR SUMMARY This Section Does Not Apply CA Building Energv Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 • Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 14 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xml NRCC-PRF-MCH-DETAILS -SECTION START - A. MECHANICAL VENTILATION AND REHEAT (Adapted from 2013-NRCC-MCH-03-E) Confirmed 1. DESIGN AIR FLOWS 2. VENTILATION (§ 120.1) 3. 4. S. M m m 8. Confirmed 3 p Rated Capacity m �_ A G z (kBtuh) M Z D Z -1 Z D X D _n — O 0 Z m O 3 H G1 ? G < CA ai D �+ Heating Cooling Design 6Z1 V z O 9 -n 9 09 n Z i Z Z T m Z Z T m r1 C rL 3 O C C O � O < T m C Z 1 < 70 p f1 m d CONDITIONED 00 n 3 O 3; n �, NA 3 Z cn Z m z 3 -+ D n m D < c ZONE NAME � D D__ 3< �� DA DmD i O H G m o A 3D z N Z T rD -_I r- m 9 p : M O r p y �+ � F0 _ O Z LA D p 9Z Z< VGZl ZGZl j _ m D M m m T z Z O A r z z D z D m O Z n 0 T 3 3 3 1 -2nd Floor HVAC -11 1,400 NA NA NA NA N HVAC -11 10,492 0.25 350 7.5 2,623 5,246 NA N ❑ ❑ TOTAL 10,492 350 1 2,623 5,246 NA ❑ ❑ B. ZONAL SYSTEM AND TERMINAL UNIT SUMMARY § 140.4 1. 2. 3. 4. S. 6. 7. 8. Confirmed Rated Capacity Airflow (cfm) Fan (kBtuh) v System ID System Type Qty Economizer Zone Name �+ Heating Cooling Design Min. HP Cycles ECM Ratio Motor 2nd Floor3-TRM Uncontrolled 18 NA NA NA 1 -2nd Floor 1400 NA NA NA NA ❑ ❑ 1 ❑ C. EXHAUST FAN SUMMARY This Section Does Not Apply D. DHW EQUIPMENT SUMMARY — (Adapted from NRCC-PLB-01) This Section Does Not Apply E. MULTI -FAMILY CENTRAL DHW SYSTEM DETAILS This Section Does Not Apply CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 E C N J CL) � 0 N Ur r, 0 0 U o N O Ln 3 W O N a o u u; E 0 w E M O C Z LL O N � Y 10 LL U 7 Uu a Cr C Z V • Ln m (14 M C c7 M J 0 0 CL 'a E E c r O v a� U R Q CD C 00 00 X I'- n W c; CL N O N v v V) E v u Z** Q C .o U u .a ai (U E O O d d U CL CL Q 0 Z 0) 0 0 C Ln -C y Z Ca O CC u G N VIV Q: N � > J W a CLJ O Q w W o W Z > N N DO J U. O O OC CL a U w H U _ Z d Fail ❑ E LL w c a 0 Pass ❑ U- 12 a V � ECMS v MCH -18A ao v w W a C O Iv V Cc v Q N Condenser Water 1"I CL MCH -17A Reset Controls i O Y Q) Q) V N c Supply Air Temp. Reset O M en N MCH -16A I C M C o C O U wTES Systems m VY MCH -15A v w v E o 0 0 CL 3 N U 0 0 E a LL Dist. Energy Storage 0 0 Q v MCH -14A DX AC 0 N E c o Auto FDD for Air & MCH -13A Zone o 00 C t 00 00 C FDD for DX Units M C 00 N 01 MCH -12A > 0 J N T o N c Q O w Auto Demand Shed O MCH -13A n sr m C Control Ol Hyd. Variable Flow J v u u w MGH -10A Control .y O E � OAC Supply Water Temp. v Z MCH -09A Reset 0 _ E E Q Valve leakage -O v w Z Y MCH -08A N , o E w w 0) V4 w cu w Supply Fan VAV 0 . N Q c Ili a MCH -07A Io -0 U C C C C Q y u MCH -06A DCV CX C C O A N O 0 Q V CL Economizer Controls W V1 Q 1 Q MCH -05A L l0 0 N O u � J Z yLL W m '01 MCH -04A Air Dist. Ducts M N l0 W H --aN a +_ E C5 T E v E Single Zone Unitary v m 0M o u Z C `J MCH -03A N _^ 3 x d o o d m N H C VI 0 vl C L o vi Outdoor Air T O W v - CL Q Q H E MCH -02A N vii x Q Q 'a E O O Z'� CL _w t v C N o c C 00 a M: 0 0 y U v a C Z o > O Q O O V 00 OC = N C Y Ul O ci W O N O 0% _a 7 C V .5 Cr Q t on Q ~ W W ~ \J Z L% 0 a y Z Ca O CC u G N VIV Q: N � > J W a CLJ O Q w W o W Z > N N DO J U. O O OC CL a U w H U _ Z d ❑ ❑ E LL w c ❑ ❑ a V � C � f0 ao W a O Iv V Cc v Q N 1"I i Q) Q) V N O M O O C o C O U m VY C f0 u w v E o 0 0 +_ 3 N U 0 0 y a LL o 0 Q 0 c 0 o 00 C t 00 00 ry 00 00 M C 00 N 01 > 0 J o N c w u O n sr C N J v u V C O C OAC C , U Z 0 _ C V OD V E Q _ J O •C -O 'O w v 0 C E 0 N N w C), o E w w 0) }c v o m v cu w 0 . a Q c Ili a Io -0 Q C V C C C C C Q o ~ 0 v ai E °c c° Y C O A N O 0 CL W C t0 ~T C W 0: L l0 0 N J m '01 Y Q N N l0 Z O --aN a +_ E C5 T E v E v m 0M o 0 Ln O Z—u C `J 7 y E� N _^ 3 U) 3 o o _ 7 v N H C VI 0 vl C L o vi M T O V U W Q H E ~ Y T C N vii V O/ 0 Y O E O O Z'� CL r t v O v u v O U1 cc M: 0 0 y Z C O c 0 00 OC m 0 O O C LL LL O 0 t on v U .M a c N a c N Z J o m J a N N Cl Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 16 of 17 Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xmi B. INDOOR CONDITIONED LIGHTING MANDATORY LIGHTING CONTROLS (Adapted from NRCC-LTI-02-E) § 130.1 This Section Does Not Apply 130.1(0) = Manual area controls; §130.0(6) = MultiLevel, §130.1(c) = Auto Shut -Off,• §130.1(d) = Mandatory Daylight; §130.1(e) = Demand Responsive C. TAILORED METHOD LIGHTING POWER ALLOWANCE SUMMARY AND CHECKLIST (Adapted from NRCC-LTI-04-E) § 140.6 General lighting power (see Table D) 0 General lighting power from special function areas (see Table E) NA Additional "use it or lose it" (See Table G) 0 Total watts 0 D. GENERAL LIGHTING POWER (Adapted from NRCC-LTI-04-E) § 140.6-D This Section Does Not Apply E. GENERAL LIGHTING FROM SPECIAL FUNCTION AREAS (Adapted from NRCC-LTI-04-E) § 140.6(c) 3H Room Number Primary Function Area Illuminance Value LUX (LUX) Room Cavity Ratio (Table G) Allowed LPO 1 Floor Area (ft) Allowed Watts Confirmed Pass Fail NA NA NA NA NA NA NA ❑ ❑ Note: Iallored Method for special Function Areas Is not currently implemented F. ROOM CAVITY RATIO (Adapted from NRCC-LTI-04-E) Rectangular Spaces Room Number Task/Activity Description Room Length (ft) Room Width (ft) Room Cavity Height (ft) RCR Confirmed Pass Fail NA NA NA NA NA NA ❑ ❑ Non -Rectangular Spaces This Section Does Not Apply Note: All applicable spaces are listed under the Non -Rectangular Spaces table CA Ruildine Fnprey Fffiripnry Sttandard5- 2013 Nonruidentlal 44mpliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 17 of 17 project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016 :ompliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xml G. ADDITIONAL "USE IT OR LOSE IT" (Adapted from NRCC-LTI-04-E) 1. 2. 3. 4. Allowed Watts Confirmed Wall Display Combined Floor Display and Task Lighting Combined Ornamental and Special Effects Lighting Very Valuable Merchandise w N Equipment Requiring Testing or Verification 0 0 0 0 0 ❑ ❑ 5. Wall Display This Section Does Not Apply 5. Floor Display and Task Lighting This Section Does Not Apply 7. Combined Ornamental and Special Effects Lighting This Section Does Not Apply B. Very Valuable Merchandise This Section Does Not Apply H. INDOOR &OUTDOOR LIGHTING ACCEPTANCE TESTS & FORMS (Adapted from NRCC-LTI-01-E and NRCC-LTO-01-E) § 130.4 Declaration of Required Acceptance Certificates (NRCA) —Acceptance Certificates that must be verified in the field. (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). Test Description Indoor Outdoor Confirmed NRCA-LTI-02-A NRCA-LTI-03-A NRCA-LTI-04-A NRCA-LTO-02-A � Equipment Requiring Testing or Verification # of units Occ Sensors / Auto Time Switch Auto Daylight Demand Responsive Outdoor Controls T T. Occupant Sensors 0 ❑ ❑ ❑ ❑ ❑ ❑ Automatic Time Switch 0 ❑ ❑ ❑ ❑ ❑ ❑ Automatic Daylighting 0 ❑ ❑ ❑ ❑ ❑ ❑ Demand Responsive 0 ❑ ❑ ❑ ❑ ❑ ❑ Outdoor Controls 0 ❑ ❑ ❑ ❑ ❑ ❑ f A RidIriine FnPrey FffiriPnry Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42 • • • ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL' ENV -MM Project'Name Date Tenant Improvement 12/14/2016 DESCRIPTION Building Envelope Measures: §110.8(a): Installed insulating material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20 Chapter 4, Article 3. §110.8(c): All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. §110.8(0: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-13 between framing members. §110.7(a): All Exterior Joints and openings in.the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.Z of §110.6(a): window area, 0.3 cfm/ft.Z of door area for residential doors, 0.3 cfm/ft.Z of door area for nonresidential single doors (swingingand sliding), and 1.0 cfm/ft.z for nonresidential double doors (swinging). §110.6(a): Fenestration U -factor shall be rated in accordance with NFRC 100, or the applicable default U -fact or. §110.6(a) : Fenestration SHGC shall be rated in accordance with NFRC 200, or NFRC 100 for site -built fenestration, or the applicable default SHGC. §110.6(b): Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016.12-14709:15:27 ID: Page 20 of 41 STATE OF CALIFORNIA Electrical Power Distribution CEC-NRCtr-ELC-01-E (Revised 05/15) CERTIFICATE OF COMPLIANCE Electrical Power Distribution Project Name: Tenant Improvement , CALIFORNIA ENERGY COMMISSION NRCC-ELC-01-E (Page 1 of 7) Date Prepared: 12/14/2016 A. General Information Project Address: 78-140 Calle Tampico Climate Zone: 15 Conditioned Floor Area 10,492 Unconditioned Floor Area 0 Building Type: .0 Nonresidential ❑ High -Rise Residential ❑ Hotel/Motel ❑ Schools ❑ Relocatable Public Schools 0 Conditioned Spaces ❑ Unconditioned Spaces Phase of Construction: ❑ New Construction ❑ Addition m Alteration CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 STATE OF CALIFORNIA Electrical Power Distribution 1-1 4 B. Electrical Service Metering ❑ Each newly installed electrical service (in both existing and newly constructed buildings) is required to be metered, as set out in Table 130.5-A, which is reproduced below. ❑ Fill out a separate line for each electrical service that is connected to the building. Electrical Field Electrical Service Schedule Service Rating Metering Capabilities (check all that are present) Inspector A B C D E F G a ? 7 ❑- SrD fD d O Jr < 'rI H T d 3 D 3 o d GJ x �_ �. CL Designation/location in building/description kVA CL `? c w fD ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑' ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Table 130.5-A - MINIMUM REQUIREMENTS FOR METERING OF ELECTRICAL LOAD More than 50kVA More than 250 kVA Services rated and less than or and less than or more than Meter Rating (kVA) 50 kVA or less equal to 250 kVA equal to 1000kVA 1000kVA Instantaneous (at the Required Required Required Required time) kW demand Historical peak demand Not required Not required Required (kW) .Required Resettable kWh Required; Required. Required Required kWh per rate period Not required Not required Not required Required CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 STATE OF CALIFORNIA Electrical Power Distribution 4 C. Disaggregation of Electrical Circuits ❑ Each newly installed switchboard, panel, and motor control center (in both existing and newly constructed buildings) is required to be disaggregated according to the requirements of Table 130.5-B, shown on the next page. ❑ Individual branch circuits, taps or disconnects that require overcurrent protection devices rated 60A or greater. ❑ As an alternative, current transformers can be added for individual branch circuits and loads throughout the building, and a permanent measurement system can be installed. In this case, disaggregated wiring would not be required as long as the metering system allows the equivalent disaggregated measurements. ❑ Fill out a separate line for each switchboard, motor control center, panelboard and subpanel. Switchboard, motor control center, panelboard or Electrical Service that supplies that subpanel switchboard or panel Electrical Service Rating Field Inspector N A B C D Designation/location in Designation/location in building/description kVA buil ding/description ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ OR Current transformers have been attached to individual branch circuits and loads throughout the building, and a permanent measurement system is installed that allows an equivalent degree of disaggregated measurement as required by the Standards.. ❑ ❑ CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 STATE OF CALIFORNIA Electrical Power Distribution CEC-N 05/1 CERTIFICATE OF COMPLIANCE Electrical Power Distribution Pro,eCtName: Tenant Improvement CALIFORNIA ENERGY COMMISSION Date Prepared: 12/14/2016 N RCC-ELC-01-E (Page 4 of 7) D. Disaggregation of Electrical Circuits (continued) Table 130.5-B - MINIMUM REQUIREMENTS FOR SEPARATION OF ELECTRICAL LOAD Table 130.5 — B sets the upper limit on how many load(s) of each type can be supplied by each feeder. A feeder may not supply loads of more than one type unless the service is rated at 50 kVA or less. For instance, on the fifth row of the table, one feeder on a service >50 kVA could be used to supply all the plug loads on a floor of a building, provided that there are no areas in which more than 25kVA of plug load is supplied to a space less than 5000sf Services rated more than Services rated more than Services rated 50kVA and less than or 250 kVA and less than or Services rated more Load Type 50 kVA or less equal to 250 kVA equal to 1000kVA than 1000kVA Lighting including exit and All lighting egress lighting and exterior Not required All lighting in aggregate All lighting disaggregated disaggregated by floor, by floor, , type or area lighting type or area HVAC systems and components including chillers, fans, heaters, All HVAC in aggregate All HVAC in aggregate furnaces, package units, cooling Not required All HVAC in aggregate and each HVAC load and each HVAC load towers, and circulation pumps rated at least 50 kVA rated at least 50kVA associated with HVAC Domestic and service water system pumps and related Not required All loads in aggregate All loads in aggregate All loads in aggregate systems and components All plug load separated by All plug loads separated All plug load in aggregate floor, type or area by floor, type or area. Plug load including appliances Groups of plug loads Groups of plug loads All groups of plug loads Not required exceeding 25 kVA rated less than 25 kVA exceeding 25 kVA exceeding 25 kVA connected load in an area connected load in an area connected load in an less than 5000 sf less than 5000 sf area less than 5000 sf Elevators, escalators, moving Not required All loads in aggregate All loads in aggregate All loads in aggregate walks, and transit systems Other individual non -HVAC loads or appliances rated.25kVA Not required All Each Each or greater Industrial and commercial load centers 25 kVA or greater including theatrical lighting Not required All Each Each installations and commercial kitchens Renewable power source (net Each group Each group Each group Each group or total) Loads associated with Not required All loads in aggregate All loads in aggregate All loads in aggregate renewable power source Charging stations for electric All loads in All loads in aggregate All loads in aggregate All loads in aggregate vehicles aggregate • CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 STATE OF CALIFORNIA Electrical Power Distribution I -_ E. Voltage Drop ❑ Attach voltage drop worksheet to this form, ❑ Field inspector has discretion to approve the worksheets; the tables shown below in this section are advisory only ❑ Feeder conductors and branch circuits that are dedicated to emergency services are exempt from these requirements. ❑ An advisory table of typical power factors is shown below Field Inspector � y H T N Feeders. Feeder conductors shall be sized for a maximum voltage drop of 2 percent at design load. ❑ ❑ Branch Circuits. Branch circuit conductors shall be sized for a maximum voltage drop of 3 percent at design load. ❑ ❑ Compliance Manual, Chapter 8, Table 8 2: Typical Power Factors for Voltage Drop Calculations Default Power Factor Default Power Factor Load Type at 120 volts at 277 volts Clarifying Notes Fluorescent lighting 0.95 0.95 Compact 0.9 (hardwired) 0.9 (hardwired) fluorescent lighting NPF magnetic ballasts use GU -24 values 0.5 (GU -24) 0.3 (GU -24) May be higher if specifications call for high LED lighting 0.7 0.5 power factor drivers Incandescent lighting 1.0 1.0 HID lighting 0.9 0.9 May be lower if NPF ballasts are specified HVAC packages 0.85 0.9 Other motors <5 HP 0.8 0.8 Other motors >5 HP 0.85 0.85 Kitchen equipment 0.9 N/A For dedicated receptacles, may be rated Receptacles 0.6 N/A according to. the load Electric heating 1.0 1.0 including hot water Other 0.85 0.85 • CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 4 STATE OF CALIFORNIA Electrical Power Distribution h CEC-NRC-ELC-01-E (Revised 05/15) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E Electrical Power Distribution .(Page 6 of 7) Project Name: Date Prepared: - Tenant Improvement 12/14/2016 F. Circuit Controls for 120 -Volt Receptacles ❑ Controlled 120 volt receptacles shall be provided, as required by Section 130.5(d) of the Standards. ❑ In open office areas, controlled circuit receptacles are not required if, at time of final permit, workstations are installed, and each workstation is equipped with an occupant sensing control that is permanently mounted in each workstation, and which controls a hardwired, nonresidential - rated power strip. Plug-in strips and other plug-in devices that incorporate an occupant sensor shall not be used for this exception. ❑ Receptacles that are only for the following purposes are exempt: -Receptacles specifically for refrigerators and water dispensers in kitchenettes. -Receptacles located a minimum of six feet above the floor that are specifically for clocks. -Receptacles for network copiers, fax machines, A/V and data equipment other than personal computers in copy rooms. Field Inspector � p) N N T N 1. At least one controlled receptacle is installed within 6 feet of each uncontrolled receptacle, or split -wired duplex receptacles are installed, that have one controlled and one uncontrolled receptacle. This applies in all of the following spaces: • Private offices, open office areas 0 • Receptions and lobbies • Conference rooms • Kitchenettes in office spaces • Copy room 2. Electric circuits serving controlled receptacles are equipped with automatic shut -OFF controls following the requirements prescribed in Section 130.1(c)1 through 5 (in many cases this will mean that the receptacles are connected ❑ ❑ to the same automatic shut -OFF system as the general lighting of the space). 3. Controlled receptacles shall have a permanent marking to differentiate them from uncontrolled receptacles. ❑. ❑ 4. For open office areas, controlled circuits shall be provided and marked to support installation and configuration of office ❑ ❑ furniture with receptacles that comply with Section 130.5(d) 1, 2, and 3. 5. For hotel and motel guest rooms at least one-half of the 120 -volt receptacles in each guest room are controlled receptacles that comply with Section 130.5(d)1, 2, and 3 (see numbers 1,2 and 3 above). Electric circuits serving ❑ controlled receptacles have captive card key controls, occupancy sensing controls, or automatic controls such that, no longer than 30 minutes after the guest room has been vacated, power is switched off. 6. Plug-in strips and other plug-in devices that incorporate an occupant sensor are not used to comply with any of these requirements. ❑ ❑ • CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 STATE OF CALIFORNIA Electrical Power Distribution CEC-NRC C-ELC-01-E (Revised 05/15) CERTIFICATE OF COMPLIANCE (Electrical Power Distribution - ProjeetName: Tenant Improvement CALIFORNIA ENERGY COMMISSION Date Prepared: 12/14/2016 NRCC-ELC-01-E (Page 7 of 7) DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Jon Scott Documentation Author Signature: company. Scott Design and Title 24, Inc, Signature Date: 12/14/2016 Address: 74-818 Velie Way, STE 8 CEA/ HERS Certification Identification (if applicable): City/state/zip: Palm Desert, CA 92260 phone: (760) 702-5406 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Gabe Lujan Responsible Designer Signature: Company: Gabe Lujan Date Signed: Address: Panorama License: City/state/zip: Palm Desert, CA 92236 Phone: (760) 578-8545 • CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Tenant Improvement Date 12/14/2016 System Name HVAC -1 Floor Area 10,492 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 18 COIL CFM Total Room Loads 28,552 Return Vented Lighting Return Air Ducts Return Fan Ventilation 5,246 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 41,600 334,934 119,697 2,890 122,334 Total Output Btuh 748,800 0 Output Btuhls ft 71.4 16,747 6,117 Cooling System 0 0 Output perSystem 41,600 208,664 13,414 5,246 244,374 Total Output Btuh 748,800 0 16,747 577,091F 133,111 0 Total Output Tons 62.4 6,117 Total Output Btuh/s ft 71.4 Total Output s ft/Ton 168.1 1378,941 Air System CFM perSystem 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 25,200 altered HVAC 537,775 176,881 467,680 Airflow cfm/s ft 2.40 Airflow cfm/Ton 403.8 Outside Air % 20.8% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 537,775 176,881 Aug 3 PM 467,680 Outside Air cfm/s ft 0.50 Jan 1 AM Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 10 Outside Air 5,246 cfm 70 OF 61 OF 110 OF 110 OF Heating Coil Supply Fan 25,200 cfm ii ° 110 F ROOM 70 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/78°F Outside Air 5,246 cfm 75/67°F 82/69°F 62/61 OF 62/61 OF 10 Cooling Coil Supply Fan 25,200 cfm LLU 63 / 62 OF 68.4% � ROOM �y 74/67°F EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2016-12-14T09:15:27 /D: Page 28 of 41 0 0 0 ZONE LOAD SUMMARY Project Name Tenant Improvement Date _ 12/14/2016 System Name HVAC -1 Floor Area 10,492 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible 2nd Floor 1.0 5,246 Aug 3 PM 28,552 547,084 218,207 2,890 367,981 TOTALS 0 0 0 5,246 Aug 3 PM 547,084 218,207 367,981 (BLOCK LOAD) EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 201 6-12-14 70 9:15:27 ID: Page 29 of 41 ROOM LOAD SUMMARY Project Name Date Tenant Improvement 12/14/2016 System Name Floor Area HVAC -1 10,492 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name I Room Name I Mult. I CFM Sensible I Latent CFM I Sensible Latent CFM I Sensible 2nd Floor I 12nd Floor Tenant Improvel 1 128,5521 334,9341 119,697 28,5521 334,9341 119,697 2,890 122,334 • PAGE TOTAL TOTAL Total includes ventilation load for zonal systems. EnerovPro 6.7 by EnerovSoft User Number: 6712 Run Code: 2016-12-14T09:1 128,5521 334,934 1 119, 697 2,8901 122,334 28, 552 334, 934 F 119, 697 2,8901 f22,334 of 41 • a L-1 ROOM HEATING PEAK LOADS Project Name Tenant Improvement Date 12/14/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Tenant Improvement Floor Area 10,492.0 It' Indoor Dry Bulb Temperature 70 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F = _ _ = = = = = = = = = = = = = = = - = = 44 Btu/hr R-30 Roof Attic 1,518.0 X X X 0.0790 44 5,277 R-19 Wall 5,740.0 0.0740 44 18,689 Exist. Single Glazed 884.0 1.1900 44 46,286 R-30 Floor no Crawlspace 10,492.0 X 0.0330 44 15,234 X X X X X X X X X X X X X X X X X X X X X X X X X X X to another room 9.00 X 0.500 Ceiling Height ACH Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 10,492 X Area Page Total /60] X AT 85,487 = 36,847 TOTAL HOURLY HEAT LOSS FOR ROOM 122,334 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14T09:15:27 ID: Page 31 of 41 • ROOM COOLING PEAK LOADS Date 12/14/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM Floor Area 10,492.0 ftz Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 74 °F Outdoor Wet Bulb Temperature 78 OF Conduction R-30 Roof Attic R-19 Wall Exist. Single Glazed Exist. Single Glazed R-19 Wall R-19 Wall Exist. Single Glazed Exist. Single Glazed R-19 Wall Area 1,518.0 1,672.0 432.0 240.0 1,192.0 1,588.0 152.0 60.0 1,288.0 X X X X X X X X X U -Value X X X X X X X X X DETD' = = = = = = = = = 0.0790 61.6 0.0740 37.3 1.1900 24.9 1.1900 24.9 0.0740 39.7 0.0740 44.8 1.1900 24.9 1.1900 24.9 0.0740 58.2 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window Window Window Window Window l ,ndow Orientation (N) (N) (N) (N) (N) (N) (N) (N) (N) Page Total Btu/hr 7,384 4,620 12,792 7,106 3,502 5,263 4,501 1.777 1 5,5511 1 52,4951 Area X X X X X X X X X SGF 37 X 37 X 37 X 37 X 37 X 37 X 37 X 37 X 37 X Sc X X X X X X X X X Weighting Factor = = = = = = = = = 16.01 0.864 0.868 24.0 0.864 0.868 16.0 0.864 0.868 16.0 0.864 0.868 24.0 0.864 0.868 16.01 0.864 0.868 16.0 0.864 0.868 24.0 0.864 0.868 16.0 0.864 0.868 Page Total Btu/hr 440 659 440 440 659 440 440 659 440 4,615 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 34,706 Occupants 1.00 X 10,492 X 300 Btu/OCC. / 30 Sgft/OCC. X 1.000 = 104,920 Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 47,984 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0 Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu[Watt X 0.000 = 0 Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 160 ] X 38 = 31,822 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 10,492 X 300 Btuh/occ. / 30 Sgft/occ. = 104,920 Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 14,777 Schedule Air Sensible Area Ceiling Height ACH AW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697 EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2016-12-14TO9:15:27 /D: Page 32 of 41 • ROOM COOLING PEAK LOADS Date 12/14/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM Floor Area 10,492.0 ft' Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 74 °F Outdoor Wet Bulb Temperature 78 OF Conduction R-30 Floor no Crawlspace Area 1 10,492.01 X X X X X X X X X U -Value X X X X X X X X X DETD' = = = = = 0.0330 38.5 16.0 37 0.864 0.868 24.0 37 0.864 0.868 16.0 37 0.864 0.868 16.0 37 0.864 0.868 Page Total 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window •Window Window Window Window Window Orientatinn (N) (N) (N) (N) (N) (N) (E) (E) (E) 1 13,3141 Area X X X X X X X X X SGF X X X X X X X X X SC X X X X X X X X X Weighting Factor 16.0 37 0.864 0.868 24.0 37 0.864 0.868 16.0 37 0.864 0.868 16.0 37 0.864 0.868 24.0 37 0.864 0.868 16.01 37 0.864 0.868 24.0 37 0.864 2.057 16.0 37 0.864 2.057 32.0 371 0.864 2.057 Page Total L Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt X 1.000 = Occupants 1.00 X 10,492 X 300 Btu/occ. / 30 Sgft/OCC. X 1.000 = Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 = Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.000 Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 / 60 ] X 38 Schedule Air Sensible Area Ceiling Height ACH AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Sched. Latent Gain Frac. Area Heat Gain. Occupants 1.00 X 10,492 X 300 Btuh/occ. / 30 Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 13,314 Btu/hr 440 659 440 440 659 440 1,562 1,041 2,083 7,762 Btu/hr 34,706 104,920 47,984 0 0 31, 822 334.934 Btu/hr Sgft/OCC. = 104,920 Btu/Watt = 0 BtuMatt = 0 • Infiltration: 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 = 14,777 Schedule Air Sensible Area Ceiling Height ACH OW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697 EnergyPm 6.7 by EnergySoft User Number: 6712 Run Code: 2016-12-14709:15:27 ID: Page 33 of 41 • • • ROOM COOLING PEAK LOADS Tenant Improvement 1211412016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM Floor Area 10,492.0 82 Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 78 OF Conduction Area U -Value DETD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window Window Window Window Window Window Sched. Orientation (E) (E) (E) (E) (S) (S) (S) (S) (S) Area X X X X X X X X X SGF X X X X X X X X X SC X X X X X X X X X Weighting Factor = = = = = = = = = 32.0 37 0.864 2.057 16.0 37 0.864 2.057 32.0 37 0.864 2.057 16.0 37 0.864 2.057 16.0 71 0.864 1.107 24.01 71 0.864 1.107 16.0 71 0.864 1.107 16.0 71 0.864 1.107 24.0 71 0.864 1.107 Page Total Weighting Btu/hr 2,083 1,041 2,083 1,041 1,086 1,629 1,086 1,086 1,629 12,765 Internal Gain Frac. Area Heat Gain Factor Btu/hr Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 34,706 Occupants 1.00 X 10,492 X 300 Btu/OCC. / 30 Sqft/occ. X 1.000 = 104,920 Receptacle 1.00 X , 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 47,984 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0 Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.000 = 0 Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 /601 X 38 = 31,822 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 10,492 X 300 Btuh/OCC. / 30 Sgft/OCC. = 104,920 Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 14,777 Schedule Air Sensible Area Ceiling Height ACH AW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697 FnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2016-12-14T09:15:27 /D: Page 34 of 41 0 • • I ROOM COOLING PEAK LOADS Tenant Improvement 12/14/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM Floor Area 10,492.0 ft2 Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 74 OF, Outdoor Wet Bulb Temperature 78 OF Conduction Area U -Value DETD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Snlar Gain Window Window Window Window Window Window Window Window Window Orientation (S) (S) (S) (S) (S) (S) (S) (S) (S) Area X X X X X X X X X SGF X X X X X X X X X SC 0.864 X 0.864 X 0.864 X 0.864 X 0.864 X 0.864 X 0.864 X 0.864 X 0.864 X Weighting Factor = = = = = = = = 16.0 71 1.107 16.0 71 1.107 24.0 71 1.107 16.0 71 1.107 16.0 71 1.107 24.01 71 1.107 16.0 71 1.107 40.0 71 1.107 60.0 71 1.107 Page Total Btu/hr 1,086 1,086 1,629 1,086 1,086 1.629 1,086 2,716 4,074 15,480 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 34,706 Occupants 1.00 X 10,492 X 300 Btu/occ. / 30 Sgft/occ. X 1.000 = 104,920 Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 47,984 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0 Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.000 = 0 Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 / 60 X 38 = 31,822 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 10,492 X 300 Btuh/OCC. / 30 Sgft/occ. = 104,920 Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 __ Schedule Air Sensible Area Ceiling Height ACH AW 1 14,7771 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14709:15:27 /D: Page 35 of 41 • CJ • ROOM COOLING PEAK LOADS Project Name Date Tenant Improvement 712/14/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM Floor Area 10,492.0 ft' Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 74 OF, Outdoor Wet Bulb Temperature 78 OF Conduction Area U -Value DETD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total o 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Weighting Solar Gain Orientation Area SGF SC Factor Btu/hr Krindow (S) 40.0 X 71 X 0.864 X 1.107 = 2,716 Window (lM 72.0 X 249 X 0.864 X 0.410 = 6,353 X X X = X X X = X X X = X X X = X X X = X X X = X X X = Page Total s,os9 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 BtuMatt X 1.000 = 34,706 Occupants 1.00 X 10,492 X 300 Btu/occ. / 30 Sqft/occ. X 1.000 = 104,920 Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 47,984 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0 Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu[Watt X 0.0001 0 Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 / 60 ] X 38 = 31,822 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 10,492 X 300 Btuh/occ. / 30 Sgft/occ. = 104,920 Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu[Watt = 0 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 =E 14,777 Schedule Air Sensible Area Ceiling Height ACH AW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14709:15:27 /D: Page 36 of 41 31 10 C] ROOM COOLING COIL LOADS Project Name Date Tenant Improvement 12/14/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Tenant Improvement Time of Peak Floor Area 10,492.0 ft' Outdoor Dry Bulb Temperature Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature Conduction Area U -Value DETD' R-30 Roof Attic R-19 Wall Exist. Single Glazed Exist. Single Glazed R-19 Wall R-19 Wall Exist. Single Glazed Exist. Single Glazed R-19 Wall 1,518.0 1,672.0 432.0 240.0 1,192.0 1,588.0 152.0 60.0 1,288.0 X X X X X X X X X 0.0790 X X X X X X X X X 61.6 = = c = = 0 = = = 0.0740 37.3 1.1900 24.9 1.1900 24.9 0.0740 39.7 0.0740 44.8 1.1900 24.9 1.1900 24.9 0.0740 58.2 t. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window Window Window Window Window Window Orientation (N) (N) (N) (N) (N) (N) (N) (N) (N) Page Total Area X X X X X X X X X SGF X X X X X X X X X SC X X X X X X X X X Weighting Factor = = = _ = = _ = 16.0 37 0.864 0.868 24.0 37 0.864 0.868 16.0 37 0.864 0.868 16.0 37 0.864 0.868 24.0 37 0.864 0.868 16.0 37 0.864 0.868 16.0 37 0.864 0.868 24.0 37 0.864 0.868 16.0 37 0.864 0.868 Page Total L Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt X 1.000 = Occupants 1.00 X 10,492 X 300 Btu/occ. / 30 Sgft/OCC. X 1.000 = Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 = Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.0001 = Aug 3 PM 112 OF 78 OF Btu/hr 7,384 4,620 12,792 7,106 3, 502 5,263 4,501 1, 777 5,551 52, 495 Btu/hr 440 659 440 440 659 440 440 659 440 4.615 Btu/hr 34,706 104,920 47,984 0 0 Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 /60] X 38 = 31,822 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334.934 Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 10,492 X 300 Btuh/OCC. / 30 Sgft/occ. = 104,920 Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Infiltration: 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 __ 14,777 Schedule Air Sensible Area Ceiling Height ACH AW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14T09:15:27 /D: Page 37 of 41 • • • ROOM COOLING COIL LOADS Project Name Date Tenant Improvement 12/14/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM Floor Area 10,492.0ft' Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 78 OF Conduction R-30 Floor no Craw/space Area 1 10,492.01 X X X X X X X X X U -Value X X X X X X X X X DETD' = = = = = = = = = 0.0330 38.5 = = = = = = = = = 16.0 37 0.864 0.868 24.0 37 0.864 0.868 16.0 37 0.864 0.868 16.0 37 0.864 0.868 Page Total 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window Window Window Window Window Window Orientation (N) (N) (N) (N) (N) (N) (E) (E) (E) Btu/hr 13,314 1 13,3141 Area X X X X X X X X X SGF X X X X X X X X X SC X X X X X X X X X Weighting Factor = = = = = = = = = 16.0 37 0.864 0.868 24.0 37 0.864 0.868 16.0 37 0.864 0.868 16.0 37 0.864 0.868 24.0 37 0.864 0.868 16.01 37 0.864 0.868 24.0 37 0.864 2.057 16.0 37 0.864 2.057 32.0 37 0.864 2.057 Page Total L Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt X 1.000 = Occupants 1.00 X 10,492 X 300 Btu/occ. / 30 Sqft/occ. X 1.000 = Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 = Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.0001 = Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 /60] X 38 = Schedule Air Sensible Area Ceiling Height ACH AT 440 659 440 440 659 440 1,562 1,041 2,083 7,762 Btu/hr 34,706 104,920 47,984 0 01 1 31,8221 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 10,492 X 300 Btuh/occ. / 30 Sgft/occ. = 104,920 Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu[Watt = 0 Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /601 X 0.00394 __ Schedule Air Sensible Area Ceiling Height ACH AW 1 14,7771 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14T09:15:27 /D: Page 38 of 41 • • ROOM COOLING COIL LOADS Project Name Date Tenant Improvement 12/14/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM Floor Area 10,492.0 ft' Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 78 OF Conduction Area U -Value DETD' Btu/hr X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X = = = = = = = = = Weighting Factor X 2.057 X 2.057 X 2.057 X 2.057 X 1.107 X 1.107 X 1.107 X 1.107 X 1.107 = = = = = = = = = 32.0 37 0.864 16.0 37 0.864 32.0 37 0.864 16.0 37 0.864 16.0 71 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Window Window Window Window Window Window Window Window Window Orientation (E) (E) (E) (E) (S) (S) (S) (S) (S) Page Total Area X X X X X X X X X SGF X X X X X X X X X SC Weighting Factor X 2.057 X 2.057 X 2.057 X 2.057 X 1.107 X 1.107 X 1.107 X 1.107 X 1.107 = = = = = = = = = 32.0 37 0.864 16.0 37 0.864 32.0 37 0.864 16.0 37 0.864 16.0 71 0.864 24.0 71 0.864 16.0 71 0.864 16.0 71 0.864 24.0 71 0.864 Page Total 71 Btu/hr 2,083 1,041 2,083 1,041 1,086 1,629 1,086 1,086 1,629 12,765, Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 BtuIWatt X 1.000 = 34,706 Occupants 1.00 X 10,492 X 300 Btu/OCC. / 30 Sqf /occ. X 1.000 = 104,920 Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 47,984 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0 Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.0001 = 0 Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 / 60 X 38 = 31,822 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 10,492 X 300 Btuh/occ. / 30 Sgft/occ. = 104,920 Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 = 14,777 Schedule Air Sensible Area Ceiling Height ACH AW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697 EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2016-12-14T09:15:27 /D: Page 39 of 41 C7 40 ROOM COOLING COIL LOADS Date 12/14/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM Floor Area 10,492.0 ft' Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 78 OF Conduction Area U -Value DETD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (`) denote conduction through an interior surface to another room. Solar Gain Window Window Window Window Window Window Window Window Window Orientation (S) (S) (S) (S) (S) (S) (S) (S) (S) Area X X X X X X X X X SGF X X X X X X X X X Sc X X X X X X X X X Weighting Factor = = = = = = = = = 16.0 71 0.864 1.107 16.0 71 0.864 1.107 24.0 71 0.864 1.107 16.0 71 0.864 1.107 16.0 71 0.864 1.107 24.01 71 0.864 1.107 16.0 71 0.864 1.107 40.0 71 0.864 1.107 60.0 71 0.864 1.107 Page Total Btu/hr 1.086 1,086 1,629 1,086 1,086 1,629 1,086 2,716 4,074 15,480 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu[Watt X 1.000 = 34,706 Occupants 1.00 X 10,492 X 300 Btu/OCC. / 30 SgtVocc. X 1.000 = 104,920 Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu[Watt X 1.000 = 47,984 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu[Watt X 1.000 = 0 Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu[Watt X 0.0001 0 Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 / 60 ] X 38 —_ 31,822 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 10,492 X 300 Btuh/occ. / 30 SgtVocc. = 104,920 Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu[Watt = 0 Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 14,777 Schedule Air Sensible Area Ceiling Height ACH AW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14709:15:27 ID: Page 40 of 41 U P.J 'ROOM COOLING COIL LOADS Project Name Date Tenant Improvement 12/14/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM Floor Area 10,492.0 ft' Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 74 OF, Outdoor Wet Bulb Temperature 78 OF Conduction Area U -Value DETD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Weighting Solar Gain Orientation Area SGF SC Factor Btu/hr Window (S) 40.0 X 71 X 0.864 X 1.107 = 2,716 Window (W) 72.0 X 249 X 0.864 X 0.410 = 6,353 X X X = X X X = X X X = X X X = X X X = X X X = X X X = Page Total 9,069 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 34,706 Occupants 1.00 X 10,492 X 300 Btu/occ. / 30 Sgft/occ. X 1.000 = 104,920 Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 47,984 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0 Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.000 = 0 Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 160 ] X 38 = F 31,822 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 10,492 X 300 Btuh/OCC. / 30 Sgft/occ. = 104,920 Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0 Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 __ 14,777 Schedule Air Sensible Area Ceiling Height ACH AW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14709:15:27 /D: Page 41 of 41