BCOM2017-000378-495 CALLE TAMPICO Q.�i
D
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number: BCOM2017-0003
Property Address: 78140 CALLE.TAM Pic D
APN: 770020023
Application Description: COMM T. I.
Property Zoning: FEB 2 12017
Application Valuation: "$150,000.00
CITY OF LA QUINTA
Applicant: DESIGN AND DEVELOPMENT DEPARTMENT
GABRIEL LUJAN
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 70001 of Division 3 of the Business a rofessions Code,
and my License is in full force and effect.
License Class: B License No.: 951607
Date: -L,% , 2 - Contractor:
OWNER -BUILDER C TION
I hereby affirm under penalty of perjury th m exempt from the Contractor's State
License Law for the following reason (Sec: 31.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500)::
(� I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his'or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(___) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and'who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued.(Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
VOICE (760) 777-7125
. FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 2/21/2017
Owner:-
DUNCAN SMITH
17 ARDENDALE CT
ALAMO, CA 92253
Contractor:
STATEWIDE SERVICES INC DBA STATEWIDE CON
73-700•DINAH SHORE DR STE 405
PALM DESERT, CA 92211
(760)699-5434
Llc. No.: 951607
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
_ I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: BENCHMARK INSURANCE COMPANY Policy Number: CST5067723
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become su "ect to the
workers' compensation provisions of Section 3700 of the LaborCod hall forthwith
comply with those
provisions.
Dat\ `/ �.� Applicant:
WARNING: FAILURE TO SECURE WORKER 0 NSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO �L PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION,DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT:' Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf.this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta,'its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of, this permit.
2. Any permit issued as a.result of this application'becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application. and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to build' g
construction, and hereby authorize representatives of this city to enter upon t .
above-mentioned property for inspection purposes.
Date: __ 1 t I r�ignaturee'(Applicant-or,Agent)
DESCRIPTION ACCOUNT QTY AMOUNT
BSAS SB1473 FEE 101-0000-20306 0 $6.00 .
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $6.00
DESCRIPTION
ACCOUNT
QTY .
AMOUNT
Credit Card Fee
101-0000-43505
0
$36.46
Total Paid for Credit Card Fee: $36.46
DESCRIPTION
ACCOUNT
QTY
AMOUNT
NON-RESIDENTIAL, EA ADDITION 2,000SF
101-0000-42403
0
$228.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
NON-RESIDENTIAL, EA ADDITION 2,000SF, PC .
101-0000-42600
0
$60.78
DESCRIPTION
ACCOUNT
QTY
AMOUNT
NON-RESIDENTIAL, FIRST 2,000SF
101-0000-42403
0
$114.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
NON-RESIDENTIAL, FIRST 2,000SF, PC
101-0000-42600
0
$88.16
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $490.94
DESCRIPTION
ACCOUNT
QTY
AMOUNT
APPLIANCE REPAIR/ALTERATION
101-0000-42402
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT
APPLIANCE REPAIR/ALTERATION PC
101-0000-42600
0
$5.07
Total Paid for MECHANICAL: $17.74
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$38.01
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$38.01
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER/VENT
101-0000-42401
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600
0
$7.60
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0.
$12.67
Total Paid for PLUMBING FEES: $121.63
DESCRIPTION
ACCOUNT
QTY
AMOUNT
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400
0
$638.40
DESCRIPTION
ACCOUNT
QTY
AMOUNT
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$510.72
DESCRIPTION
ACCOUNT
QTY
AMOUNT
REMODEL, FIRST 100 SF
101-0000-42400
0
$51.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$141:36
Total Paid for REMODEL: $1,342.16
DESCRIPTION_ ,
ACCOUNT
QTY
AMOUNT
SMI - COMMERCIAL
101-0000-20308
0
$42.00
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $42.00
DESCRIPTION
ACCOUNT
QTY '
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611.
0
$5.00
1
i
Qin nCcity of La quinta.
building 8T Safety Division
Permit # o3 _ 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-701,2
Building Permit Application and Tracking Sheet
Project Address: ` O . C-ft1 \ e wner's Name: . ?_—XC in F
A. P. Number:
Address: ll e 4 FAt co
Legal Description:
City, ST, Zip: L&1 �.
ontra r:
C ct 0 •
Telephone:
Address:
Project Description: '
City, ST, Zip:
Telephone: '
e h o .
P
e' lLdo.
State Lic. # :
City Lie. #;
Arch.,`Engr., Signe . QDQ-�jyt
Address:G
V./
t
'�G'` ILM
City., ST, Zip: 0.`µ _ a'�
1 ` S'��• S$ S1hW S1�
5
an:
Occupancy:
ConTelephone:—I�DS fractt n TYPe: cY
State Lie. 4:
Add n ?iter Demo
oProJectPe circle one � N w
tY
Name of Contact Person:
�tG
Sq. Ft.: t'b �orl
#Stories: 2
#Units:
Telephone # of Contact Person:
' S164 SrEstimated
Value of Project: On 0
APPLICANT: DO NOT WRITE BELOW THIS LINE
to
Submittal
Req'd
Rcc'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item .
, Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Cafes.
Called Contact Person
Plan Check Balance •
Title 24 Cafes.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°° Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing -
Grant Deed
Plans picked up
II.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Rcyiew, ready for corrections/issue
Devcloper.Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
P•ub. Wks. Appr
Date of permit issue
School Fees,
I
Total Permit Fees
officG"tco
BUILDING ENERGY,ANALYSIS REPORT.
a;.
PROJECT:
Tenant Improvement
. 78-140 Calle Tampico ;
La Quinta, CA 92253
Project Designer:
Gabe Lujan
Panorama .
Palm Desert, CA 92236 ;
(760) 578-8545
CITY OF LA QUINTA
Report Prepared yBUILDING & SAFETY DEPT.
Jon Scott , APPR VED.
FOR CON RUCTION
`g• Scott Design and Title 4, Inc,
74-818 Velie Way, T8 '21►s�
Palm Desert, CA 9
(760) 702-540.6
RECEIVED,
JAN 10 2017
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
Job Number:
Date: RECEIVED
12/14/2016 FEB 0 7 2017
CITY OF LA QUINTA
The EnergyPro computer program has been used to perform the calculations summarized in this complianceGPMMUI#7360EMSLQWENTnd is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
`• This program developed by EriergySoft,. LLC —.www.energysoft.com.
�`* ?
EnergyPro 6.7 by EnergySoft User Number: 6712 ID:
i
0 0 -
project Name:
78-140 Calle Tampico
NRCC-PRF-01-E
Page 1 of 17
>roject Address:
78-140 Calle Tampico La Quinta 92253
Calculation Date/Time:
09:02, Wed, Dec 14, 2016 '
ompliance Scope:
ExistingAddition
Input File Name:
Calle Tampico -Gabe Lujan-16.xml
A. PROJECT GENERAL INFORMATION
1.
Project Location (city)
La Quinta
7.
# of dwelling units
0
2.
CA Zip Code
92253
8.
Standards Version
Compliance2015
3.
Climate Zone
15
9.
Compliance Software (version)
EnergyPro 6.7
4.
Total Conditioned Floor Area
10,492 ft2
10.
Building Orientation (deg)
(S) 180 deg
S.
Total Unconditioned Floor Area
0 ft2
11.
Permitted Scope of Work
ExistingAddition
6.
# of Stories (Habitable Above Grade)
2
12
Building Type(s)
Nonresidential
B. COMPLIANCE RESULTS FOR PERFORMANCE COMPONENTS (Annual TDV Energy Use, kBtu/ft 2 -yr)
§ 140.1
BUILDING COMPLIES
1. Energy Component
2. Standard Design (TDV)
3. Proposed Design (TDV)
4. Compliance Margin (TDV)
S. Percent Better than Standard
Space Heating
12.7
4.8
7.9
62.2%
Space Cooling
271.4
208.3
63.1
23.2%
Indoor Fans
68.8
98.6
-29.8
-43.3%
Heat Rejection
Pumps & Misc.
0.4
-
0.4
Domestic Hot Water
Indoor Lighting
83.9
83.9
0.0%
COMPLIANCE TOTAL
437.2
395.6
41.6
9.5%
Receptacle
91.3
91.3
0.0
0.0%
Process
Process Ltg
TOTAL
528.5
486.9
41.6
7.9%
CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
Project Name:
78-140 Calle Tampico
NRCC-PRF-01-E
Page 2 of 17
Project Address:
78-140 Calle Tampico La Quinta 92253
Calculation Date/Time:
09:02, Wed, Dec 14, 2016
Compliance Scope:
ExistingAddition
Input File Name:
Calle Tampico -Gabe Lujan-16.xml
C. PRIORITY PLAN CHECK/ INSPECTION ITEMS (in order of highest to lowest TDV energy savings) '
1st
Space Cooling: Check envelope and mechanical
Compliance Margin By Energy Component (from Table B column 4)
Space Cooling f
I Space Heating
Pumps & Misc. j
2nd
Space Heating: Check envelope and mechanical
3rd
Pumps & Misc.: Check mechanical
4th
Heat Rejection: Check envelope and mechanical
Heat Rejection
5th
Domestic Hot Water: Check mechanical
Domestic Hot Water '
Indoor Lighting
6th
Indoor Lighting: Check lighting
Indoor Fans
7th
Indoor Fans: Check envelope and mechanical
_ -
EnecgylCredit�
;��Pen�alty
D. EXCEPTIONAL CONDITIONS
The building does not include service water heating. Verify that service water heating is not required and is not included in the design.
E. HERS VERIFICATION
This Section Does Not Apply
F. ADDITIONAL REMARKS
None Provided
CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
Project Name:
78-140 Calle Tampico
NRCC-PRF-01-E
Page 3 of 17
Project Address:
78-140 Calle Tampico La Quinta 92253
Calculation Date/Time:
09:02, Wed, Dec 14, 2016
Compliance Scope:
ExistingAddition
Input File Name:
Calle Tampico -Gabe Lujan-16.xm1
G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY
Identify which building components use the performance or prescriptive path for compliance. "NA"= not in project
For components that utilize the performance path, indicate the sheet number that includes mandatory notes on plans.
Building Component
Compliance Path
Compliance Forms (required forsubmittal)
Location of Mandatory Notes on
Plans
Envelope
❑ Performance
NRCC-PRF-ENV-DETAILS (section of the NRCC-PRF-01-E)
❑ Prescriptive
NRCC-ENV-01 / 02 / 03 / 04 / 05 / 06-E
® NA
Mechanical
® Performance
NRCC-PRF-MCH-DETAILS (section of the NRCC-PRF-01-E)
❑ Prescriptive
NRCC-MCH-01 / 02 / 03 / 04 / 05 / 06 / 07-E
❑ NA
Domestic Hot Water
❑ Performance
NRCC-PRF-PLB-DETAILS (section of the NRCC-PRF-01-E)
❑ Prescriptive
NRCC-PLB-01-E
® NA
Lighting (Indoor Conditioned)
® Performance
NRCC-PRF-LTI-DETAILS (section of the NRCC-PRF-01-E)
❑ Prescriptive
NRCC-LTI-01 / 02 / 03 / 04 / 05-E
❑ NA
Covered Process:
Commercial Kitchens
❑ Performance
S2 (section of the NRCC-PRF-01-E)
❑ Prescriptive
NRCC PRC O1/ 03-E
® NA
Covered Process:
Computer Rooms
❑ Performance
S3 (section of the NRCC-PRF-01-E)
❑ Prescriptive
NRCC-PRC-01/ 04-E
® NA
Covered Process:
Laboratory Exhaust
❑ Performance
S4 (section of the NRCC-PRF-01-E)
ElPrescriptive
NRCC-PRC O1/ 09-E
® NA
CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 4 of 17
Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016
Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xml
G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY
The following building components are only eligible for prescriptive compliance. Indicate which ore
The following building components may have mandatory requirements per Part 6. Indicate
relevant to the project.
which are relevant to the project.
Yes NA
Prescriptive Requirement
Compliance Forms
Yes NA
Mandatory Requirement
Compliance Forms
Lighting (Indoor
Commissioning: §120.8
❑ ®
NRCC-LTI-01 / 02 / 03 / 04 / 05-E
E]®
Simple Systems
NRCC-CXR-01 / 02 / 03 / 05-E
Unconditioned) §140.6 .
❑ - ®
"Complex Systems
NRCC-CXR-01 / 02 / 04 / 05-E
❑ ®
Lighting (Outdoor) §14
NRCC-LTO-01 / 02 / 03-E
® ❑
Electrical: §130.5
NRCC-ELC-01-E
❑ ®
Lighting (Sign) §140.8
NRCC-LTS-01-E
❑ ®
Solar Ready: §110.10
NRCC-SRA-01 / 02-E
Covered Process: §120.6
NRCC-PRC-01-E
❑ . ®
Parking Garage
NRCC-PRC-02-E
Solar Thermal Water
E]®
Commercial Refrigeration
NRCC-PRC-05-E VEl
Heating: §140.5
❑ ®
Warehouse Refrigeration
NRCC-PRC-06/07/08-E 4/1
❑ - ®
Compressed Air
NRCC-PRC-10-E
❑ ®
Process Boilers
NRCC-PRC-11-E
CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
-
0 0 0
Project Name:
78-140 Calle Tampico
NRCC-PRF-01-E
Page 5 of 17
Project Address:
78-140 Calle Tampico La Quinta 92253
Calculation Date/Time:
09:02, Wed, Dec 14, 2016
Compliance Scope:
ExistingAddition
Input File Name:
Calle Tampico -Gabe Lujan-16.xml
H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCI/NRCA/NRCV) —
Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance
(Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify).
See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment.
Confirmed
Building Component
Compliance Forms (required for submittal)
Pass
Fail
Envelope
❑ NRCI-ENV-01-E - For all buildings
❑
❑
❑ NRCA-ENV-02-F- NFRC label verification for fenestration
❑
❑
Mechanical
® NRCI-MCH-01-E - For all buildings with Mechanical Systems
❑
❑
® NRCA-MCH-02-A- Outdoor Air
❑
❑
® NRCA-MCH-03-A—Constant Volume Single Zone HVAC
❑
❑
❑ NRCA-MCH-04-H- Air Distribution Duct Leakage
❑
❑
❑ NRCA-MCH-05-A- Air Economizer Controls
❑
❑
❑ NRCA-MCH-06-A- Demand Control Ventilation
❑
❑
❑ NRCA-MCH-07-A—Supply Fan Variable Flow Controls
❑
❑
❑ NRCA-MCH-08-A- Valve Leakage Test
❑
❑
❑ NRCA-MCH-09-A — Supply Water Temp Reset Controls
❑
❑
❑ NRCA-MCH-10-A- Hydronic System Variable Flow Controls
❑
❑
❑ NRCA-MCH-1I-A—Auto Demand Shed Controls
❑
❑
❑ NRCA-MCH-12-A- Packaged Direct Expansion Units
❑
❑
❑ NRCA-MCH-13-A- Air Handling Units and Zone Terminal Units
❑
❑
❑ NRCA-MCH-14-A- Distributed Energy Storage
❑
❑
❑ NRCA-MCH-15-A—Thermal Energy Storage
❑
❑
❑ NRCA-MCH-16-A- Supply Air Temp Reset Controls
❑
❑
❑ NRCA-MCH-17-A— Condensate Water Temp Reset Controls
❑
❑
❑ NRCA-MCH-18-A- Energy Management Controls Systems
❑
❑
❑ NRCV-MCH-04-H- Duct Leakage Test
❑
❑
CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
•
0 0 �
Project Name:
78-140 Calle Tampico
NRCC-PRF-01-E
Page 6 of 17
Project Address:
78-140 Calle Tampico La Quinta 92253
Calculation Date/Time:
09:02, Wed, Dec 14, 2016
Compliance Scope:
ExistingAddition
Input File Name:
Calle Tampico -Gabe Lujan-16.xml
H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCI/NRCA/NRCV) —
Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance
(Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify).
See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment.
Confirmed
Building Component
Compliance Forms (required for submittal)
Pass
Fail
Plumbing
❑ NRCI-PLB-01-E - For all buildings with Plumbing Systems
❑
❑
❑ NRCI-PLB-02-E - required on central systems in high-rise residential, hotel/motel application.
❑
❑
❑ NRCI-PLB-03-E - Single dwelling unit systems in high-rise residential, hotel/motel application.
❑
❑
❑ NRCI-PLB-21-E - HERS verified central systems in high-rise residential, hotel/motel application.
❑
❑
❑ NRCI-PLB-22-E - HERS verified single dwelling unit systems in high-rise residential, hotel/motel application.
❑
❑
❑ NRCV-PLB-21-H- HERS verified central systems in high-rise residential, hotel/motel application.
❑
❑
❑ NRCV-PLB-22-H - HERS verified single dwelling unit systems in high-rise residential, hotel/motel application.
❑
❑
❑ NRCI-STH-01-E - Any solar water heating
❑
❑
Indoor Lighting
® NRCI-LTI-01-E - For all buildings
❑
❑
❑ NRCI-LTI-02-E - Lighting control system, or for an Energy Management Control System (EMCS)
❑
❑
❑ NRCI-LTI-03-E - Line -voltage track lighting integral current limiter, or for a supplementary overcurrent protection panel used to
energize only line -voltage track lighting
❑
❑
❑ NRCI-LTI-04-E - Two interlocked systems serving an auditorium, a convention center, a conference room, or a theater
❑
❑
❑ NRCI-LTI-05-E -Lighting Control Credit Power Adjustment Factor (PAF)
❑
❑
❑ NRCI-LTI-06-E - Additional wattage installed in a video conferencing studio
❑
❑
❑ NRCA-LTI-02-A - Occupancy sensors and automatic time switch controls.
❑
❑
❑ NRCA-LTI-03-A - Automatic daylighting controls
❑
❑
❑ NRCA-LTI-04-A - Demand responsive lighting controls
❑
❑
Outdoor Lighting
❑ NRCI-LTO-01-E— Outdoor Lighting
❑
❑
❑ NRCI-LTO-02-E- EMCS Lighting Control System
❑
❑
❑ NRCA-LTO-02-A -Outdoor Lighting Control
❑
❑
Sign Lighting
❑ N RCI-LTS-01-E —Sign Lighting
❑
❑
Electrical
® NRCI-ELC-01-E - Electrical Power Distribution
❑
❑
Photovoltaic
❑ NRCI-SPV-01-E Photovoltaic Systems
❑
❑
CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
•
Project Name:
78-140 Calle Tampico
NRCC-PRF-01-E
Page 7 of 17
Project Address:
78-140 Calle Tampico La Quinta 92253
Calculation Date/Time:
09:02, Wed, Dec 14, 2016
Compliance Scope:
ExistingAddition
Input File Name:
Calle Tampico -Gabe Lujan-16.xml
H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCI/NRCA/NRCV) —
Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance
(Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify).
See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment.
Confirmed
Building Component
Compliance Forms (required for submittal)
Pass
Fail
Covered Process
❑ NRCI-PRC-01-E Refrigerated Warehouse
❑
❑
❑ NRCA-PRC-01-F- Compressed Air Systems
❑
❑
❑ NRCA-PRC-02-F- Kitchen Exhaust
❑
❑
❑ NRCA-PRC-03-F- Garage Exhaust
❑
❑
❑ NRCA-PRC-04-F- Refrigerated Warehouse- Evaporator Fan Motor Controls
❑
❑
❑ NRCA-PRC-05-F- Refrigerated Warehouse- Evaporative Condenser Controls •
❑
❑
❑ NRCA-PRC-06-F- Refrigerated Warehouse- Air Cooled Condenser Controls
❑
❑
❑ NRCA-PRC-07F- Refrigerated Warehouse- Variable Speed Compressor
❑
❑
❑ NRCA-PRC-08-F- Electrical Resistance Underslab Heating System
❑
❑
I. ENVELOPE GENERAL INFORMATION (See NRCC-PRF-ENV-DETAILS for more information)
1.
Total Conditioned Floor Area
10,492 ft2
5. Number of Floors Above Grade
2
Confirmed
2.
Total Unconditioned Floor Area
0 ft2
6. Number of Floors Below Grade
0
�
d
N
T
y
=
3.
Addition Conditioned Floor Area 0 ft2
4.
Addition Unconditioned Floor Area 0 ft2
7. Opaque Surfaces & Orientation 8. Total Gross Surface Area 9. Total Fenestration Area 10. Window to Wall Ratio
North Wall
1,952 ft2
280 ft2
14.3%
❑
❑
East Wall
1,360 ft2
168 ft2
12.4%
❑
❑
South Wall
1,952 ft2
364 ft2
18.6%
❑
❑
West Wall
1,360 ft2
72 ft2
05.3%
❑
❑
Total
6,624 ft2
884 ft2
13.3%
❑
❑
Roof
1,518 ft2
0 ft2
00.0%
❑
❑
CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
•
Project Name:
78-140 Calle Tampico
NRCC-PRF-01-E
Page 8 of 17
Project Address:
78-140 Calle Tampico La Quinta 92253
Calculation Date/Time:
09:02, Wed, Dec 14, 2016
Compliance Scope:
ExistingAddition
Input File Name:
Calle Tampico -Gabe Lujan-16.xml
J. FENESTRATION ASSEMBLY SUMMARY
§ 110.6
Confirmed
1.
2.
3.
4.
5.
6.
7.
8.
9.
Surface Name
Surface Type
Z
Area (ft)
Framing
Type
Cavity
R -Value
Continuous
R -Value
U -Factor / F -Factor
/ C -Factor
iv
v.
a
R-30 Roof Attic9
Roof
Fenestration Assembly Name /
Metal
30
NA
U -Factor: 0.070
Overall
Overall
Overall
d
VT
H
°'
Wood
Fenestration Type
Certification Method 1
Assembly Method
Area ft2
❑
❑
R-30 Floor no Crawlspace54
ExteriorFloor
10492
Wood
Tag or I.D.
NA
U -Factor: 0.033
E
❑❑
U-factor
SHGC
VT
N
Wood
13
Exist. Single Glazed
Vertical Fenestration
DefaultPerformance
Manufactured
884
1.19
0.83
1 0.77
E
❑
❑
'Newly installed fenestration shall have a certified NFRC Label Certificate or use the CEC default tables found in Toble 110.6-A and Table 110.6-8. Center of Glass (COG) values are for the glass -only, determined by the manufacturer, and are shown for ease
of verification. Site -built fenestration values are calculated per Nonresidential Appendix NA6 and are used in the analysis.
z Status: N - New, A -Altered, E - Existing
Taking compliance credit for fenestration shading devices? (if "Yes", see NRCC-PRF-ENV-DETAILS for more information)
K. OPAQUE SURFACE ASSEMBLY SUMMARY
§ 120.7/ § 140.3
Confirmed
1.
2.
3.
4.
5.
6.
7.
8.
Surface Name
Surface Type
Z
Area (ft)
Framing
Type
Cavity
R -Value
Continuous
R -Value
U -Factor / F -Factor
/ C -Factor
iv
v.
a
R-30 Roof Attic9
Roof
1518
Metal
30
NA
U -Factor: 0.070
E
❑
❑
R-19 Wallll
ExteriorWall
6624
Wood
19
NA
U -Factor: 0.072
E
❑
❑
R-30 Floor no Crawlspace54
ExteriorFloor
10492
Wood
30
NA
U -Factor: 0.033
E
❑❑
NA
R-0 interior surface56
InteriorWall
825
Wood
13
NA
U -Factor: 0.095
E
❑
❑
`Status: N- New A - Altered, E -Existing
L. ROOFING PRODUCT SUMMARY
§ 140.3
Confirmed
1.
2.
3.
4.
S.
6.
7.
Aged Solar
Thermal
Cool Roof
V
N
v
Product Type
Product >_251b ft1
SRI
CRRC Product 10 Number
-
Reflectance
Emittance
Credit
R-30 Roof Attic9
No
0.08
0.75
NA
No
NA
❑
❑
CA Building Energy Efflclencv Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
• 0
Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 9 of 17
Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016
Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xmi
M. HVAC SYSTEM SUMMARY (see NRCC-PRF-MCH-DETAILS for more information)
I § 110.1 / § 110.2
Dry System Equipment' (Fan & Economizer info included below in Table N)
Confirmed
1.
2.
3.
4.
S.
6.
7.,
8.
9.
10.
11.
23.
24.
Air
System Type
Total Heating
Supp Heat
Supp Heat
Total Cooling
Efficiency
cY
Acceptance
Testing
a,
.o
a
d
c
Equip Name
Equip Type
3
(Simple or
Qty
Output
Source (Y/N)
Output
Output
(kBtu/h)
Required? (Y/N)
N
N
Qty
GPM
HP
Complex 4)
N
(kBtu/h)
CFM
(kBtuh)
(kBtu/h)
s
Control
CFM
HP
Cooling
Heating
HVAC -11
SZHP (Split3Phase)
Simple
18
42
No
0
42
SEER -15.0
HSPF-8.0
Yes
A
❑
❑
Wet System Equipment 2
Pumps
Confirmed
Confirmed
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
Air
M
Rated Capacity
Tank
Economizer Type
N
VSD
L
�
N
T
°'
Equip Name
Equip Type
Qty
Vol (gal)
(kBtu/h)
Efficiency
Standby Loss
Ext. R
Qty
GPM
HP
(Y/N)
N
CFM
CFM
HP
BHP
(inch
Control
CFM
HP
BHP
Value
Control
a
'Dry System Equipment includes furnaces, air handling units, heat pumps, etc.
Z Wet System Equipment includes boilers, chillers, cooling towers, water heaters, etc.
3 Simple Systems must complete NRCC-CXR-03-E commissioning design review farm
4 Complex Systems must complete NRCC-CXR-04-E commissioning design review form
S A summary of which acceptance tests are applicable is provided in NRCC-PRF-MCH-DETAILS
6 Status: N - New, A - Altered, E - Existing
Discrepancy between modeled and designed equipment sizing? (if "Yes", see Table F. "Additional Remarks" for an explanation) No
N. ECONOMIZER & FAN SYSTEMS SUMMARY'
§ 140.4
Confirmed
1.
2.
3.
4.
S.
Outside
Supply Fan
Return Fan
Air
M
T
Economizer Type
N
°'
TSP
TSP
Equip Name
(if present)
CFM
CFM
HP
BHP
(inch
Control
CFM
HP
BHP
(inch
Control
WC)
WC)
HVAC -11
291
1 1400
0.500
0.500
1.13
ConstantVolume
NA
NA
NA
NA
NA
NoEconomizer
1 ❑
tEl
1 Mechanical ventilation calculations and exhaust fans are included in the NRCC-PRF-MCH-DETAILS section
CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
Project Name:
78-140 Calle Tampico
NRCC-PRF-01-E
Page 10 of 17
Project Address:
78-140 Calle Tampico La Quinta 92253
Calculation Date/Time:
09:02, Wed, Dec 14, 2016
Compliance Scope:
ExistingAddition
Input File Name:
Calle Tampico -Gabe Lujan-.16.xmi
O. EQUIPMENT CONTROLS
§ 120.2
Confirmed
1.
2.
3.
a
-n
—
Equip Name
Equip Type
Controls
No DCV Controls
..
HVAC -11
SZHP
No Economizer
❑
❑
Lighting Control Credits
Additional (Custom) Allowance
No Supply Air Temp. Control
—
P. SYSTEM DISTRIBUTION SUMMARY §120.4/ § 140.4(i)
This Section Does Not Apply
Does the Project Include Zonal Systems? (if "Yes", see NRCC-PRF-MCH-DETAILS for system information) No
Does the Project Include a Solar Hot Water System? (if "Yes", see NRCC-PRF-MCH-DETAILS for system information) No
Multifamily or Hotel/ Motel Occupancy? (if "Yes", see NRCC-PRF-MCH-DETAILS for DHW system information) No k
Q. INDOOR CONDITIONED LIGHTING GENERAL INFO (see NRCC-PRF-LTI-DETAILS for more info)'
§ 140.6
Confirmed
1.
2.
3.
4.
S.
..
.T
1
Occupancy Type
Conditioned floor Area z
Installed Lighting Power
Lighting Control Credits
Additional (Custom) Allowance
V
—
(ftz)
(Watts)
(Watts)
Area Category Footnotes
Tailored Method (Watts)
❑
❑
(Watts)
Retail Merchandise Sales,
10,492
10,170
0
0
0
❑
❑
Wholesale Showroom
Building Totals:
10,492
10,170
0
1 See Table 140.6-C
d See NRCC-LTI-01-E for unconditioned spaces _
3Lighting information for existing spaces modeled is not included in the table .
CA Buildine Energy Efficign4y $tgndards- 2013 Nonresidential Compliance
Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
Project Name:
78-140 Calle Tampico
NRCC-PRF-01-E
Page 11 of 17
Project Address:
78-140 Calle Tampico La Quinta 92253
Calculation Date/Time:
09:02, Wed, Dec 14, 2016
compliance Scope:
ExistingAddition
Input File Name:
Calle Tampico -Gabe Lujan-16.xm1
R. INDOOR CONDITIONED LIGHTING SCHEDULE (Adapted from NRCC-LTI-01-E)1
§ 130.0
Luminaire Schedule (includes all permanent installed lighting in
Natural Gas
(therms/yr)
Total Annual Baseline
conditioned space, and portable lighting over 0.3 w/ftz in
Installed Watts (Conditioned)
Confirmed
offices)
0
Complete Luminaire Description (i.e.,
How Wattage is Determined
Name or Item Tag
3-1amp fluorescent troffer, F32T8,
Watts per luminaire
Total Number
Luminaires
Installed Watts
Pass
Fail
CEC Default
According to
one dimmable electronic ballast)
from NA8
§130.0(c)
41
(1) 4 ft Fluorescent
32
Yes
No
9
288
❑
❑
3x4led
(3) 4 ft Fluorescent
54
Yes
No
183
9,882
❑
❑
llf lighting power densities were used in the compliance model Building Departments will need to check prescriptive forms for Luminaire Schedule details.
il. COVERED PROCESS SUMMARY — ENCLOSED PARKING GARAGES § 140.9
This Section Does Not Apply
52. COVERED PROCESS SUMMARY — COMMERCIAL KITCHENS § 140.9
This Section Does Not Apply
53. COVERED PROCESS SUMMARY—COMPUTER ROOMS § 140.9
This Section Does Not Apply
54. COVERED PROCESS SUMMARY — LABORATORY EXHAUSTS § 140.9
This Section Does Not Apply
T. UNMET LOAD HOURS
This Section Does Not Apply
U. ENERGY USE SUMMARY
Electric
(kWh/yr)
Natural Gas
(therms/yr)
Total Annual Baseline
186463
706.784
Total Annual Proposed
186048
0
CA Building Engrgy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
Project Name: 78-140 Calle Tampico NRCC-PRF-01-E Page 12 of 17
Project Address: 78-140 Calle Tampico La Quinta 92253 Calculation Date/Time: 09:02, Wed, Dec 14, 2016
Compliance Scope: ExistingAddition Input File Name: Calle Tampico -Gabe Lujan-16.xml
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
§ 10-103
1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Jon Scott
Signature:
Company: Scott Design and Title 24, Inc,
Address: 74-818 Velie Way, STE 8 Signature Date:
12-14-16
City/State/Zip: Palm Desert CA 92260 CEA Identification (If applicable):
Phone: (760) 702-5406
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am
1
licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect.
1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its
2
preparation; and that I am a licensed contractor performing this work.
1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to
3
Business and Professions Code Sections 5537, 5538 and 6737.1.
Responsible Envelope Designer Name: Gabe Lujan
Signature: NOT IN SCOPE
Company: Gabe Lujan
Address: Panorama Date Signed:
City/State/Zip: Palm Desert CA 92236 Declaration Statement Type:
Phone: (760) 578-8545 Title: License #:
Responsible Lighting Designer Name: Gabe Lujan
Signature:
Company: Gabe Lujan
Address: Panorama Date Signed:
City/State/Zip: Palm Desert CA 92236 Declaration Statement Type:
Phone: (760) 578-8545 Title: License #:
Responsible Mechanical Designer Name: Jon d. Scott
Signature:
Company: Scott Design and Title 24, Inc.
Address: 74-818 Velie Way, STE 8 Date Signed:
12-14-16
City/State/Zip: Palm Desert CA 92260 Declaration Statement Type:
Phone: (760) 702-5406 Title:
License #:
CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
Project Name:
78-140 Calle Tampico
NRCC-PRF-01-E
Page 13 of 17
Project Address:
78-140 Calle Tampico La Quinta 92253
Calculation Date/Time:
09:02, Wed, Dec 14, 2016
Compliance Scope:
ExistingAddition
Input File Name:
Calle Tampico -Gabe Lujan-16.xml
NRCC-PRF-ENV-DETAILS -SECTION START
A. OPAQUE SURFACE ASSEMBLY DETAILS
Confirmed
1.
2.
3.
4.
v
'^
T
c
Surface Name
Surface Type
Description of Assembly Layers
Notes
Asphalt shingles - 1/4 in.
Vapor permeable felt - 1/8 in.
R-30 Roof Attic9
Roof
Plywood - 1/2 in.
❑
❑
Air - Cavity - Wall Roof Ceiling - 4 in. or more
Metal framed roof, 16in. OC, 9.2Sin., R-30
Gypsum Board - 1/2 in.
Stucco - 7/8 in.
R-19 Wall11
ExteriorWall
Vapor permeable felt - 1/8 in.
❑
❑
Wood framed wall, 16in. OC, 5.5in., R-19
Gypsum Board - 1/2 in.
Wood framed floor, 24in. OC, 9.25in., R-30
R-30 Floor no
ExteriorFloor
Plywood - 1/2 in.
❑
❑
Crawlspace54
Carpet - 3/4 in.
Stucco - 7/8 in.
R-0 interior surface56
InteriorWall
Vapor permeable felt - 1/8 in.
❑
❑
.Wood framed wall, 16in. OC, 3.5in., R-13
Gypsum Board - 1/2 in.
B. OVERHANG DETAILS (Adapted from NRCC-ENV-02-E)
rhis Section Does Not Apply
C. OPAQUE DOOR SUMMARY
This Section Does Not Apply
CA Building Energv Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
•
Project Name:
78-140 Calle Tampico
NRCC-PRF-01-E
Page 14 of 17
Project Address:
78-140 Calle Tampico La Quinta 92253
Calculation Date/Time:
09:02, Wed, Dec 14, 2016
Compliance Scope:
ExistingAddition
Input File Name:
Calle Tampico -Gabe Lujan-16.xml
NRCC-PRF-MCH-DETAILS -SECTION START -
A. MECHANICAL VENTILATION AND REHEAT (Adapted from 2013-NRCC-MCH-03-E)
Confirmed
1. DESIGN AIR FLOWS
2. VENTILATION (§ 120.1)
3.
4.
S.
M
m m
8.
Confirmed
3
p
Rated Capacity
m
�_
A
G
z
(kBtuh)
M
Z D Z
-1 Z
D
X
D
_n —
O
0
Z
m O
3
H
G1
?
G
<
CA
ai
D
�+
Heating
Cooling
Design
6Z1
V z
O 9
-n 9
09
n
Z i
Z
Z
T m
Z
Z
T
m
r1
C
rL 3
O C
C
O
� O
<
T m
C
Z
1
<
70
p
f1
m
d
CONDITIONED
00
n 3 O 3;
n
�,
NA
3
Z
cn Z
m
z
3
-+
D
n m
D
<
c
ZONE NAME
�
D D__
3< ��
DA
DmD
i
O
H G
m
o
A
3D
z
N
Z
T
rD
-_I
r-
m
9 p
: M
O
r
p y
�+
�
F0
_
O
Z
LA
D
p 9Z
Z<
VGZl
ZGZl
j
_ m
D
M
m
m
T
z
Z
O
A
r
z
z
D
z
D
m
O
Z
n
0
T
3
3
3
1 -2nd Floor
HVAC -11
1,400 NA
NA
NA
NA
N
HVAC -11 10,492
0.25
350
7.5
2,623
5,246
NA
N
❑
❑
TOTAL 10,492
350
1
2,623
5,246
NA
❑
❑
B. ZONAL SYSTEM AND TERMINAL UNIT SUMMARY
§ 140.4
1.
2.
3.
4.
S.
6.
7.
8.
Confirmed
Rated Capacity
Airflow (cfm)
Fan
(kBtuh)
v
System ID
System Type
Qty
Economizer
Zone Name
�+
Heating
Cooling
Design
Min.
HP
Cycles
ECM
Ratio
Motor
2nd Floor3-TRM
Uncontrolled
18
NA
NA
NA
1 -2nd Floor
1400
NA
NA
NA
NA
❑
❑
1 ❑
C. EXHAUST FAN SUMMARY
This Section Does Not Apply
D. DHW EQUIPMENT SUMMARY — (Adapted from NRCC-PLB-01)
This Section Does Not Apply
E. MULTI -FAMILY CENTRAL DHW SYSTEM DETAILS
This Section Does Not Apply
CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
E
C
N J
CL)
� 0
N Ur
r, 0 0
U
o N O
Ln 3
W O N
a o u
u;
E
0
w E
M
O C Z
LL O N
� Y
10 LL
U 7
Uu a
Cr C
Z V
•
Ln
m
(14
M
C
c7
M
J
0 0
CL 'a
E E c
r O
v a�
U R Q
CD
C
00 00 X
I'- n W
c;
CL
N O
N
v v V)
E v u
Z**
Q C
.o
U u .a
ai (U E
O O
d d U
CL
CL
Q
0
Z
0)
0
0
C
Ln
-C
y Z
Ca O
CC u
G N
VIV
Q: N
� > J
W a
CLJ
O Q w
W o
W Z
> N
N
DO J
U.
O O OC
CL
a
U
w H U
_ Z
d
Fail
❑
E
LL
w
c
a
0
Pass
❑
U-
12
a
V �
ECMS
v MCH
-18A
ao
v
w
W a
C
O
Iv
V Cc
v
Q N
Condenser Water
1"I
CL
MCH -17A
Reset Controls
i
O
Y
Q)
Q)
V N
c
Supply Air Temp. Reset
O M
en
N
MCH -16A
I
C
M
C
o
C
O
U
wTES
Systems
m
VY
MCH -15A
v
w
v E o
0
0
CL
3 N U
0
0
E
a LL
Dist. Energy Storage
0
0
Q
v
MCH -14A
DX AC
0
N
E
c
o
Auto FDD for Air &
MCH -13A
Zone
o 00
C
t
00
00
C
FDD for DX Units
M C 00
N
01
MCH -12A
> 0 J
N
T
o
N
c
Q
O
w
Auto Demand Shed
O
MCH -13A
n
sr
m
C
Control
Ol
Hyd. Variable Flow
J
v
u
u
w
MGH -10A
Control
.y
O
E
�
OAC
Supply Water Temp.
v
Z
MCH -09A
Reset
0 _
E
E
Q
Valve leakage
-O
v
w
Z
Y
MCH -08A
N
,
o E
w
w
0)
V4
w
cu
w
Supply Fan VAV
0 .
N
Q
c Ili
a
MCH -07A
Io
-0
U
C
C
C
C
Q
y
u
MCH -06A
DCV
CX
C
C
O A
N O 0
Q
V
CL
Economizer Controls
W
V1
Q
1
Q
MCH -05A
L l0
0 N
O
u
�
J
Z
yLL
W
m '01
MCH -04A
Air Dist. Ducts
M
N l0
W
H
--aN a
+_
E C5
T E
v E
Single Zone Unitary
v
m 0M
o
u
Z
C `J
MCH -03A
N
_^ 3
x
d
o
o
d
m
N H
C VI
0 vl
C L
o vi
Outdoor Air
T O
W
v
-
CL
Q
Q
H E
MCH -02A
N vii
x
Q
Q
'a
E
O
O
Z'�
CL
_w
t
v
C
N
o c
C
00
a
M:
0
0
y
U
v
a
C
Z
o >
O
Q
O O
V
00
OC
=
N
C Y
Ul O
ci
W
O
N
O
0%
_a 7 C V
.5 Cr
Q
t
on
Q
~
W W ~ \J
Z
L%
0
a
y Z
Ca O
CC u
G N
VIV
Q: N
� > J
W a
CLJ
O Q w
W o
W Z
> N
N
DO J
U.
O O OC
CL
a
U
w H U
_ Z
d
❑
❑
E
LL
w
c
❑
❑
a
V �
C �
f0
ao
W a
O
Iv
V Cc
v
Q N
1"I
i
Q)
Q)
V N
O M
O
O
C
o
C
O
U
m
VY
C
f0
u
w
v E o
0
0
+_
3 N U
0
0
y
a LL
o
0
Q
0
c
0
o 00
C
t
00
00
ry
00
00
M C 00
N
01
> 0 J
o
N
c
w
u
O
n
sr
C
N
J
v
u
V
C
O
C
OAC
C , U
Z
0 _
C V OD
V
E
Q
_
J O •C
-O
'O
w
v
0 C E
0
N
N
w C),
o E
w
w
0)
}c v
o m v
cu
w
0 .
a
Q
c Ili
a
Io
-0
Q C
V C
C
C
C
C
Q
o ~
0
v ai E
°c
c°
Y
C
O A
N O 0
CL
W
C t0
~T C W
0:
L l0
0 N
J
m '01
Y Q
N
N l0
Z
O
--aN a
+_
E C5
T E
v E
v
m 0M
o
0
Ln O
Z—u
C `J
7 y
E�
N
_^ 3
U)
3
o
o
_
7 v
N H
C VI
0 vl
C L
o vi
M
T O
V U
W
Q
H E
~ Y
T C
N vii
V
O/
0
Y O
E
O
O
Z'�
CL
r
t
v
O
v
u v
O
U1
cc
M:
0
0
y
Z
C
O
c
0
00
OC
m
0
O
O C
LL
LL
O
0
t
on
v
U .M
a
c
N
a
c
N
Z
J
o m
J
a
N
N
Cl
Project Name:
78-140 Calle Tampico
NRCC-PRF-01-E
Page 16 of 17
Project Address:
78-140 Calle Tampico La Quinta 92253
Calculation Date/Time:
09:02, Wed, Dec 14, 2016
Compliance Scope:
ExistingAddition
Input File Name:
Calle Tampico -Gabe Lujan-16.xmi
B. INDOOR CONDITIONED LIGHTING MANDATORY LIGHTING CONTROLS (Adapted from NRCC-LTI-02-E) § 130.1
This Section Does Not Apply
130.1(0) = Manual area controls; §130.0(6) = MultiLevel, §130.1(c) = Auto Shut -Off,• §130.1(d) = Mandatory Daylight; §130.1(e) = Demand Responsive
C. TAILORED METHOD LIGHTING POWER ALLOWANCE SUMMARY AND CHECKLIST (Adapted from NRCC-LTI-04-E) § 140.6
General lighting power (see Table D) 0
General lighting power from special function areas (see Table E) NA
Additional "use it or lose it" (See Table G) 0
Total watts 0
D. GENERAL LIGHTING POWER (Adapted from NRCC-LTI-04-E) § 140.6-D
This Section Does Not Apply
E. GENERAL LIGHTING FROM SPECIAL FUNCTION AREAS (Adapted from NRCC-LTI-04-E)
§ 140.6(c) 3H
Room Number
Primary Function Area
Illuminance Value
LUX
(LUX)
Room Cavity Ratio
(Table G)
Allowed LPO
1
Floor Area (ft)
Allowed Watts
Confirmed
Pass
Fail
NA
NA
NA
NA
NA
NA
NA
❑
❑
Note: Iallored Method for special Function Areas Is not currently implemented
F. ROOM CAVITY RATIO (Adapted from NRCC-LTI-04-E)
Rectangular Spaces
Room Number
Task/Activity Description
Room Length (ft)
Room Width (ft)
Room Cavity Height (ft)
RCR
Confirmed
Pass
Fail
NA
NA
NA
NA
NA
NA
❑
❑
Non -Rectangular Spaces
This Section Does Not Apply
Note: All applicable spaces are listed under the Non -Rectangular Spaces table
CA Ruildine Fnprey Fffiripnry Sttandard5- 2013 Nonruidentlal 44mpliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
project Name:
78-140 Calle Tampico
NRCC-PRF-01-E
Page 17 of 17
project Address:
78-140 Calle Tampico La Quinta 92253
Calculation Date/Time:
09:02, Wed, Dec 14, 2016
:ompliance Scope:
ExistingAddition
Input File Name:
Calle Tampico -Gabe Lujan-16.xml
G. ADDITIONAL "USE IT OR LOSE IT" (Adapted from NRCC-LTI-04-E)
1.
2.
3.
4.
Allowed Watts
Confirmed
Wall Display
Combined Floor Display and Task
Lighting
Combined Ornamental and Special
Effects Lighting
Very Valuable Merchandise
w
N
Equipment Requiring
Testing or Verification
0
0
0
0
0
❑
❑
5. Wall Display
This Section Does Not Apply
5. Floor Display and Task Lighting
This Section Does Not Apply
7. Combined Ornamental and Special Effects Lighting
This Section Does Not Apply
B. Very Valuable Merchandise
This Section Does Not Apply
H. INDOOR &OUTDOOR LIGHTING ACCEPTANCE TESTS & FORMS (Adapted from NRCC-LTI-01-E and NRCC-LTO-01-E)
§ 130.4
Declaration of Required Acceptance Certificates (NRCA) —Acceptance Certificates that must be verified in the field. (Retain copies and verify forms are completed and signed to post in field for
Field Inspector to verify).
Test Description
Indoor
Outdoor
Confirmed
NRCA-LTI-02-A
NRCA-LTI-03-A
NRCA-LTI-04-A
NRCA-LTO-02-A
�
Equipment Requiring
Testing or Verification
# of units
Occ Sensors / Auto Time
Switch
Auto Daylight
Demand Responsive
Outdoor Controls
T
T.
Occupant Sensors
0
❑
❑
❑
❑
❑ ❑
Automatic Time Switch
0
❑
❑
❑
❑
❑ ❑
Automatic Daylighting
0
❑
❑
❑
❑
❑ ❑
Demand Responsive
0
❑
❑
❑
❑
❑ ❑
Outdoor Controls
0
❑
❑
❑
❑
❑ ❑
f A RidIriine FnPrey FffiriPnry Standards- 2013 Nonresidential Compliance Report Version: NRCC-PRF-01-E-06212016-760 Report Generated at: 2016-12-14 09:03:42
•
•
•
ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL' ENV -MM
Project'Name
Date
Tenant Improvement
12/14/2016
DESCRIPTION
Building Envelope Measures:
§110.8(a): Installed insulating material shall have been certified by the manufacturer to comply with the California Quality
Standards for insulating material, Title 20 Chapter 4, Article 3.
§110.8(c): All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of
Sections 2602 and 707 of Title 24, Part 2.
§110.8(0: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value
of no less than R-13 between framing members.
§110.7(a): All Exterior Joints and openings in.the building that are observable sources of air leakage shall be caulked, gasketed,
weatherstripped or otherwise sealed.
Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.Z of
§110.6(a): window area, 0.3 cfm/ft.Z of door area for residential doors, 0.3 cfm/ft.Z of door area for nonresidential single doors
(swingingand sliding), and 1.0 cfm/ft.z for nonresidential double doors (swinging).
§110.6(a): Fenestration U -factor shall be rated in accordance with NFRC 100, or the applicable default U -fact or.
§110.6(a) : Fenestration SHGC shall be rated in accordance with NFRC 200, or NFRC 100 for site -built fenestration, or the
applicable default SHGC.
§110.6(b): Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be
weatherstripped (except for unframed glass doors and fire doors).
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016.12-14709:15:27 ID: Page 20 of 41
STATE OF CALIFORNIA
Electrical Power Distribution
CEC-NRCtr-ELC-01-E (Revised 05/15)
CERTIFICATE OF COMPLIANCE
Electrical Power Distribution
Project Name:
Tenant Improvement ,
CALIFORNIA ENERGY COMMISSION
NRCC-ELC-01-E
(Page 1 of 7)
Date Prepared:
12/14/2016
A. General Information
Project Address:
78-140 Calle Tampico
Climate Zone:
15
Conditioned Floor Area
10,492
Unconditioned Floor Area
0
Building Type:
.0 Nonresidential ❑ High -Rise Residential
❑ Hotel/Motel
❑ Schools
❑ Relocatable Public Schools 0 Conditioned Spaces
❑ Unconditioned Spaces
Phase of Construction:
❑ New Construction ❑ Addition
m Alteration
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015
STATE OF CALIFORNIA
Electrical Power Distribution
1-1
4
B. Electrical Service Metering
❑ Each newly installed electrical service (in both existing and newly constructed buildings) is required to be metered, as set out in Table 130.5-A,
which is reproduced below.
❑ Fill out a separate line for each electrical service that is connected to the building.
Electrical
Field
Electrical Service Schedule
Service Rating
Metering Capabilities (check all that
are present)
Inspector
A
B
C
D
E
F
G
a ?
7
❑- SrD
fD d
O
Jr
< 'rI
H
T
d
3
D 3 o
d GJ
x
�_
�.
CL
Designation/location in building/description
kVA
CL `? c
w
fD
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑'
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
Table 130.5-A - MINIMUM REQUIREMENTS FOR METERING OF ELECTRICAL LOAD
More than 50kVA
More than 250 kVA
Services rated
and less than or
and less than or
more than
Meter Rating (kVA)
50 kVA or less
equal to 250 kVA
equal to 1000kVA
1000kVA
Instantaneous (at the
Required
Required
Required
Required
time) kW demand
Historical peak demand
Not required
Not required
Required
(kW)
.Required
Resettable kWh
Required;
Required.
Required
Required
kWh per rate period
Not required
Not required
Not required
Required
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015
STATE OF CALIFORNIA
Electrical Power Distribution
4
C. Disaggregation of Electrical Circuits
❑ Each newly installed switchboard, panel, and motor control center (in both existing and newly constructed buildings) is required to be
disaggregated according to the requirements of Table 130.5-B, shown on the next page.
❑ Individual branch circuits, taps or disconnects that require overcurrent protection devices rated 60A or greater.
❑ As an alternative, current transformers can be added for individual branch circuits and loads throughout the building, and a permanent
measurement system can be installed. In this case, disaggregated wiring would not be required as long as the metering system allows the
equivalent disaggregated measurements.
❑ Fill out a separate line for each switchboard, motor control center, panelboard and subpanel.
Switchboard, motor control center, panelboard or Electrical Service that supplies that
subpanel switchboard or panel Electrical Service Rating
Field
Inspector
N
A B C
D
Designation/location in
Designation/location in building/description kVA
buil ding/description
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
OR
Current transformers have been attached to individual branch circuits and loads throughout the building, and a permanent
measurement system is installed that allows an equivalent degree of disaggregated measurement as required by the Standards..
❑
❑
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance
May 2015
STATE OF CALIFORNIA
Electrical Power Distribution
CEC-N
05/1
CERTIFICATE OF COMPLIANCE
Electrical Power Distribution
Pro,eCtName: Tenant Improvement
CALIFORNIA ENERGY COMMISSION
Date Prepared: 12/14/2016
N RCC-ELC-01-E
(Page 4 of 7)
D. Disaggregation of Electrical Circuits (continued)
Table 130.5-B - MINIMUM REQUIREMENTS FOR SEPARATION OF ELECTRICAL LOAD
Table 130.5 — B sets the upper limit on how many load(s) of each type can be supplied by each feeder. A feeder may not supply loads of more than
one type unless the service is rated at 50 kVA or less. For instance, on the fifth row of the table, one feeder on a service >50 kVA could be used to
supply all the plug loads on a floor of a building, provided that there are no areas in which more than 25kVA of plug load is supplied to a space less
than 5000sf
Services rated more than
Services rated more than
Services rated
50kVA and less than or
250 kVA and less than or
Services rated more
Load Type
50 kVA or less
equal to 250 kVA
equal to 1000kVA
than 1000kVA
Lighting including exit and
All lighting
egress lighting and exterior
Not required
All lighting in aggregate
All lighting disaggregated
disaggregated by floor,
by floor,
, type or area
lighting
type or area
HVAC systems and components
including chillers, fans, heaters,
All HVAC in aggregate
All HVAC in aggregate
furnaces, package units, cooling
Not required
All HVAC in aggregate
and each HVAC load
and each HVAC load
towers, and circulation pumps
rated at least 50 kVA
rated at least 50kVA
associated with HVAC
Domestic and service water
system pumps and related
Not required
All loads in aggregate
All loads in aggregate
All loads in aggregate
systems and components
All plug load separated by
All plug loads separated
All plug load in aggregate
floor, type or area
by floor, type or area.
Plug load including appliances
Groups of plug loads
Groups of plug loads
All groups of plug loads
Not required
exceeding 25 kVA
rated less than 25 kVA
exceeding 25 kVA
exceeding 25 kVA
connected load in an area
connected load in an area
connected load in an
less than 5000 sf
less than 5000 sf
area less than 5000 sf
Elevators, escalators, moving
Not required
All loads in aggregate
All loads in aggregate
All loads in aggregate
walks, and transit systems
Other individual non -HVAC
loads or appliances rated.25kVA
Not required
All
Each
Each
or greater
Industrial and commercial load
centers 25 kVA or greater
including theatrical lighting
Not required
All
Each
Each
installations and commercial
kitchens
Renewable power source (net
Each group
Each group
Each group
Each group
or total)
Loads associated with
Not required
All loads in aggregate
All loads in aggregate
All loads in aggregate
renewable power source
Charging stations for electric
All loads in
All loads in aggregate
All loads in aggregate
All loads in aggregate
vehicles
aggregate
•
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015
STATE OF CALIFORNIA
Electrical Power Distribution
I -_
E. Voltage Drop
❑ Attach voltage drop worksheet to this form,
❑ Field inspector has discretion to approve the worksheets; the tables shown below in this section are advisory only
❑ Feeder conductors and branch circuits that are dedicated to emergency services are exempt from these requirements.
❑ An advisory table of typical power factors is shown below
Field
Inspector
�
y
H
T
N
Feeders. Feeder conductors shall be sized for a maximum voltage drop of 2 percent at design load.
❑
❑
Branch Circuits. Branch circuit conductors shall be sized for a maximum voltage drop of 3 percent at design load.
❑
❑
Compliance Manual, Chapter 8, Table 8 2: Typical Power Factors for Voltage Drop Calculations
Default Power Factor
Default Power Factor
Load Type
at 120 volts
at 277 volts
Clarifying Notes
Fluorescent lighting
0.95
0.95
Compact
0.9 (hardwired)
0.9 (hardwired)
fluorescent lighting
NPF magnetic ballasts use GU -24 values
0.5 (GU -24)
0.3 (GU -24)
May be higher if specifications call for high
LED lighting
0.7
0.5
power factor drivers
Incandescent
lighting
1.0
1.0
HID lighting
0.9
0.9
May be lower if NPF ballasts are specified
HVAC packages
0.85
0.9
Other motors <5 HP
0.8
0.8
Other motors >5 HP
0.85
0.85
Kitchen equipment
0.9
N/A
For dedicated receptacles, may be rated
Receptacles
0.6
N/A
according to. the load
Electric heating
1.0
1.0
including hot water
Other
0.85
0.85
•
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015
4
STATE OF CALIFORNIA
Electrical Power Distribution
h
CEC-NRC-ELC-01-E (Revised 05/15) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E
Electrical Power Distribution .(Page 6 of 7)
Project Name: Date Prepared: -
Tenant Improvement 12/14/2016
F. Circuit Controls for 120 -Volt Receptacles
❑ Controlled 120 volt receptacles shall be provided, as required by Section 130.5(d) of the Standards.
❑ In open office areas, controlled circuit receptacles are not required if, at time of final permit, workstations are installed, and each workstation is
equipped with an occupant sensing control that is permanently mounted in each workstation, and which controls a hardwired, nonresidential -
rated power strip. Plug-in strips and other plug-in devices that incorporate an occupant sensor shall not be used for this exception.
❑ Receptacles that are only for the following purposes are exempt:
-Receptacles specifically for refrigerators and water dispensers in kitchenettes.
-Receptacles located a minimum of six feet above the floor that are specifically for clocks.
-Receptacles for network copiers, fax machines, A/V and data equipment other than personal computers in copy rooms.
Field
Inspector
�
p)
N
N
T
N
1. At least one controlled receptacle is installed within 6 feet of each uncontrolled receptacle, or split -wired duplex
receptacles are installed, that have one controlled and one uncontrolled receptacle. This applies in all of the following
spaces:
• Private offices, open office areas
0
• Receptions and lobbies
• Conference rooms
• Kitchenettes in office spaces
• Copy room
2. Electric circuits serving controlled receptacles are equipped with automatic shut -OFF controls following the
requirements prescribed in Section 130.1(c)1 through 5 (in many cases this will mean that the receptacles are connected
❑
❑
to the same automatic shut -OFF system as the general lighting of the space).
3. Controlled receptacles shall have a permanent marking to differentiate them from uncontrolled receptacles.
❑.
❑
4. For open office areas, controlled circuits shall be provided and marked to support installation and configuration of office
❑
❑
furniture with receptacles that comply with Section 130.5(d) 1, 2, and 3.
5. For hotel and motel guest rooms at least one-half of the 120 -volt receptacles in each guest room are controlled
receptacles that comply with Section 130.5(d)1, 2, and 3 (see numbers 1,2 and 3 above). Electric circuits serving
❑
controlled receptacles have captive card key controls, occupancy sensing controls, or automatic controls such that, no
longer than 30 minutes after the guest room has been vacated, power is switched off.
6. Plug-in strips and other plug-in devices that incorporate an occupant sensor are not used to comply with any of these
requirements.
❑
❑
•
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015
STATE OF CALIFORNIA
Electrical Power Distribution
CEC-NRC C-ELC-01-E (Revised 05/15)
CERTIFICATE OF COMPLIANCE
(Electrical Power Distribution
- ProjeetName: Tenant Improvement
CALIFORNIA ENERGY COMMISSION
Date Prepared: 12/14/2016
NRCC-ELC-01-E
(Page 7 of 7)
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Jon Scott
Documentation Author Signature:
company. Scott Design and Title 24, Inc,
Signature Date: 12/14/2016
Address: 74-818 Velie Way, STE 8
CEA/ HERS Certification Identification (if applicable):
City/state/zip: Palm Desert, CA 92260
phone: (760) 702-5406
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design
identified on this Certificate of Compliance (responsible designer).
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system
design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information
provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement
agency for approval with this building permit application.
5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this
Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name: Gabe Lujan
Responsible Designer Signature:
Company: Gabe Lujan
Date Signed:
Address: Panorama
License:
City/state/zip: Palm Desert, CA 92236
Phone: (760) 578-8545
•
CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance May 2015
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Tenant Improvement
Date
12/14/2016
System Name
HVAC -1
Floor Area
10,492
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
18
COIL
CFM
Total Room Loads 28,552
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 5,246
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 41,600
334,934
119,697 2,890
122,334
Total Output Btuh 748,800
0
Output Btuhls ft 71.4
16,747
6,117
Cooling System
0
0
Output perSystem 41,600
208,664
13,414 5,246
244,374
Total Output Btuh 748,800
0
16,747
577,091F 133,111
0
Total Output Tons 62.4
6,117
Total Output Btuh/s ft 71.4
Total Output s ft/Ton 168.1
1378,941
Air System
CFM perSystem
1,400
HVAC EQUIPMENT SELECTION
Airflow cfm
25,200
altered HVAC
537,775 176,881
467,680
Airflow cfm/s ft
2.40
Airflow cfm/Ton
403.8
Outside Air % 20.8%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
537,775 176,881
Aug 3 PM
467,680
Outside Air cfm/s ft 0.50
Jan 1 AM
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
10
Outside Air
5,246 cfm
70 OF
61 OF 110 OF 110 OF
Heating Coil Supply Fan
25,200 cfm
ii
°
110 F
ROOM
70 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling
Peak)
112/78°F
Outside Air
5,246 cfm
75/67°F
82/69°F 62/61 OF 62/61 OF
10
Cooling Coil Supply Fan
25,200 cfm
LLU
63 / 62 OF
68.4% � ROOM �y
74/67°F
EnergyPro 6.7 by EnergySoft
User Number: 6712 Run Code: 2016-12-14T09:15:27
/D: Page 28 of 41
0 0 0
ZONE LOAD SUMMARY
Project Name
Tenant Improvement
Date _
12/14/2016
System Name
HVAC -1
Floor Area
10,492
ZONE LOAD SUMMARY
ZONAL SYSTEM COOLING PEAK
HEATING PEAK
ZONE NAME SYSTEM NAME
Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent
CFM Sensible
2nd Floor
1.0 5,246 Aug 3 PM 28,552 547,084 218,207
2,890 367,981
TOTALS 0 0 0 5,246 Aug 3 PM 547,084 218,207
367,981
(BLOCK LOAD)
EnergyPro 6.7 by EnergySoft User Number: 6712
Run Code: 201 6-12-14 70 9:15:27 ID:
Page 29 of 41
ROOM LOAD SUMMARY
Project Name Date
Tenant Improvement 12/14/2016
System Name Floor Area
HVAC -1 10,492
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name I Room Name I Mult. I CFM Sensible I Latent CFM I Sensible Latent CFM I Sensible
2nd Floor I 12nd Floor Tenant Improvel 1 128,5521 334,9341 119,697 28,5521 334,9341 119,697 2,890 122,334
• PAGE TOTAL
TOTAL
Total includes ventilation load for zonal systems.
EnerovPro 6.7 by EnerovSoft User Number: 6712 Run Code: 2016-12-14T09:1
128,5521 334,934
1 119, 697
2,8901
122,334
28, 552 334, 934
F
119, 697
2,8901
f22,334
of 41
•
a
L-1
ROOM HEATING PEAK LOADS
Project Name
Tenant Improvement
Date
12/14/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name 2nd Floor Tenant Improvement
Floor Area 10,492.0 It'
Indoor Dry Bulb Temperature 70 °F
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
=
_
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
-
=
=
44
Btu/hr
R-30 Roof Attic
1,518.0
X
X
X
0.0790
44
5,277
R-19 Wall
5,740.0
0.0740
44
18,689
Exist. Single Glazed
884.0
1.1900
44
46,286
R-30 Floor no Crawlspace
10,492.0
X
0.0330
44
15,234
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to another room
9.00 X 0.500
Ceiling Height ACH
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 10,492 X
Area
Page Total
/60] X
AT
85,487
= 36,847
TOTAL HOURLY HEAT LOSS FOR ROOM 122,334
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14T09:15:27 ID: Page 31 of 41
•
ROOM COOLING PEAK LOADS
Date
12/14/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM
Floor Area 10,492.0 ftz Outdoor Dry Bulb Temperature 112 OF
Indoor Dry Bulb Temperature 74 °F Outdoor Wet Bulb Temperature 78 OF
Conduction
R-30 Roof Attic
R-19 Wall
Exist. Single Glazed
Exist. Single Glazed
R-19 Wall
R-19 Wall
Exist. Single Glazed
Exist. Single Glazed
R-19 Wall
Area
1,518.0
1,672.0
432.0
240.0
1,192.0
1,588.0
152.0
60.0
1,288.0
X
X
X
X
X
X
X
X
X
U -Value
X
X
X
X
X
X
X
X
X
DETD'
=
=
=
=
=
=
=
=
=
0.0790
61.6
0.0740
37.3
1.1900
24.9
1.1900
24.9
0.0740
39.7
0.0740
44.8
1.1900
24.9
1.1900
24.9
0.0740
58.2
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Solar Gain
Window
Window
Window
Window
Window
Window
Window
Window
l ,ndow
Orientation
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
Page Total
Btu/hr
7,384
4,620
12,792
7,106
3,502
5,263
4,501
1.777
1 5,5511
1 52,4951
Area
X
X
X
X
X
X
X
X
X
SGF
37 X
37 X
37 X
37 X
37 X
37 X
37 X
37 X
37 X
Sc
X
X
X
X
X
X
X
X
X
Weighting
Factor
=
=
=
=
=
=
=
=
=
16.01
0.864
0.868
24.0
0.864
0.868
16.0
0.864
0.868
16.0
0.864
0.868
24.0
0.864
0.868
16.01
0.864
0.868
16.0
0.864
0.868
24.0
0.864
0.868
16.0
0.864
0.868
Page Total
Btu/hr
440
659
440
440
659
440
440
659
440
4,615
Sched. Weighting
Internal Gain Frac. Area Heat Gain Factor Btu/hr
Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 34,706
Occupants 1.00 X 10,492 X 300 Btu/OCC. / 30 Sgft/OCC. X 1.000 = 104,920
Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 47,984
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0
Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu[Watt X 0.000 = 0
Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 160 ] X 38 = 31,822
Schedule Air Sensible Area Ceiling Height ACH AT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 10,492 X 300 Btuh/occ. / 30 Sgft/occ. = 104,920
Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0
Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 14,777
Schedule Air Sensible Area Ceiling Height ACH AW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697
EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2016-12-14TO9:15:27 /D: Page 32 of 41
•
ROOM COOLING PEAK LOADS
Date
12/14/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM
Floor Area 10,492.0 ft' Outdoor Dry Bulb Temperature 112 OF
Indoor Dry Bulb Temperature 74 °F Outdoor Wet Bulb Temperature 78 OF
Conduction
R-30 Floor no Crawlspace
Area
1 10,492.01
X
X
X
X
X
X
X
X
X
U -Value
X
X
X
X
X
X
X
X
X
DETD'
=
=
=
=
=
0.0330
38.5
16.0
37
0.864
0.868
24.0
37
0.864
0.868
16.0
37
0.864
0.868
16.0
37
0.864
0.868
Page Total
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Solar Gain
Window
Window
Window
Window
•Window
Window
Window
Window
Window
Orientatinn
(N)
(N)
(N)
(N)
(N)
(N)
(E)
(E)
(E)
1 13,3141
Area
X
X
X
X
X
X
X
X
X
SGF
X
X
X
X
X
X
X
X
X
SC
X
X
X
X
X
X
X
X
X
Weighting
Factor
16.0
37
0.864
0.868
24.0
37
0.864
0.868
16.0
37
0.864
0.868
16.0
37
0.864
0.868
24.0
37
0.864
0.868
16.01
37
0.864
0.868
24.0
37
0.864
2.057
16.0
37
0.864
2.057
32.0
371
0.864
2.057
Page Total L
Sched. Weighting
Internal Gain Frac. Area Heat Gain Factor
Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt X 1.000 =
Occupants 1.00 X 10,492 X 300 Btu/occ. / 30 Sgft/OCC. X 1.000 =
Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 =
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 =
Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.000
Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 / 60 ] X 38
Schedule Air Sensible Area Ceiling Height ACH AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Sched.
Latent Gain Frac. Area Heat Gain.
Occupants 1.00 X 10,492 X 300 Btuh/occ. / 30
Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413
13,314
Btu/hr
440
659
440
440
659
440
1,562
1,041
2,083
7,762
Btu/hr
34,706
104,920
47,984
0
0
31, 822
334.934
Btu/hr
Sgft/OCC. = 104,920
Btu/Watt = 0
BtuMatt = 0
• Infiltration: 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 = 14,777
Schedule Air Sensible Area Ceiling Height ACH OW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697
EnergyPm 6.7 by EnergySoft User Number: 6712 Run Code: 2016-12-14709:15:27 ID: Page 33 of 41
•
•
•
ROOM COOLING PEAK LOADS
Tenant Improvement 1211412016
ROOM INFORMATION DESIGN CONDITIONS
Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM
Floor Area 10,492.0 82 Outdoor Dry Bulb Temperature 112 OF
Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 78 OF
Conduction Area U -Value DETD' Btu/hr
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
Page Total 0
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Solar Gain
Window
Window
Window
Window
Window
Window
Window
Window
Window
Sched.
Orientation
(E)
(E)
(E)
(E)
(S)
(S)
(S)
(S)
(S)
Area
X
X
X
X
X
X
X
X
X
SGF
X
X
X
X
X
X
X
X
X
SC
X
X
X
X
X
X
X
X
X
Weighting
Factor
=
=
=
=
=
=
=
=
=
32.0
37
0.864
2.057
16.0
37
0.864
2.057
32.0
37
0.864
2.057
16.0
37
0.864
2.057
16.0
71
0.864
1.107
24.01
71
0.864
1.107
16.0
71
0.864
1.107
16.0
71
0.864
1.107
24.0
71
0.864
1.107
Page Total
Weighting
Btu/hr
2,083
1,041
2,083
1,041
1,086
1,629
1,086
1,086
1,629
12,765
Internal Gain Frac. Area Heat Gain Factor Btu/hr
Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 34,706
Occupants 1.00 X 10,492 X 300 Btu/OCC. / 30 Sqft/occ. X 1.000 = 104,920
Receptacle 1.00 X , 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 47,984
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0
Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.000 = 0
Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 /601 X 38 = 31,822
Schedule Air Sensible Area Ceiling Height ACH AT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 10,492 X 300 Btuh/OCC. / 30 Sgft/OCC. = 104,920
Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0
Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 14,777
Schedule Air Sensible Area Ceiling Height ACH AW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697
FnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2016-12-14T09:15:27 /D: Page 34 of 41
0
•
•
I ROOM COOLING PEAK LOADS
Tenant Improvement 12/14/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM
Floor Area 10,492.0 ft2 Outdoor Dry Bulb Temperature 112 OF
Indoor Dry Bulb Temperature 74 OF, Outdoor Wet Bulb Temperature 78 OF
Conduction Area U -Value DETD' Btu/hr
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
Page Total 0
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Snlar Gain
Window
Window
Window
Window
Window
Window
Window
Window
Window
Orientation
(S)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
Area
X
X
X
X
X
X
X
X
X
SGF
X
X
X
X
X
X
X
X
X
SC
0.864 X
0.864 X
0.864 X
0.864 X
0.864 X
0.864 X
0.864 X
0.864 X
0.864 X
Weighting
Factor
=
=
=
=
=
=
=
=
16.0
71
1.107
16.0
71
1.107
24.0
71
1.107
16.0
71
1.107
16.0
71
1.107
24.01
71
1.107
16.0
71
1.107
40.0
71
1.107
60.0
71
1.107
Page Total
Btu/hr
1,086
1,086
1,629
1,086
1,086
1.629
1,086
2,716
4,074
15,480
Sched. Weighting
Internal Gain Frac. Area Heat Gain Factor Btu/hr
Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 34,706
Occupants 1.00 X 10,492 X 300 Btu/occ. / 30 Sgft/occ. X 1.000 = 104,920
Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 47,984
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0
Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.000 = 0
Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 / 60 X 38 = 31,822
Schedule Air Sensible Area Ceiling Height ACH AT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 10,492 X 300 Btuh/OCC. / 30 Sgft/occ. = 104,920
Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0
Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 __
Schedule Air Sensible Area Ceiling Height ACH AW
1 14,7771
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14709:15:27 /D: Page 35 of 41
•
CJ
•
ROOM COOLING PEAK LOADS
Project Name
Date
Tenant Improvement
712/14/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name 2nd Floor Tenant Improvement
Time of Peak
Aug 3 PM
Floor Area 10,492.0 ft'
Outdoor Dry Bulb Temperature
112 OF
Indoor Dry Bulb Temperature 74 OF,
Outdoor Wet Bulb Temperature
78 OF
Conduction Area
U -Value DETD'
Btu/hr
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
Page
Total
o
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Weighting
Solar Gain Orientation Area
SGF SC
Factor
Btu/hr
Krindow (S) 40.0
X 71 X 0.864 X
1.107 =
2,716
Window (lM 72.0
X 249 X 0.864 X
0.410 =
6,353
X X X
=
X X X
=
X X X
=
X X X
=
X X X
=
X X X
=
X X X
=
Page Total
s,os9
Sched.
Weighting
Internal Gain Frac. Area Heat Gain
Factor
Btu/hr
Lights 1.00 X 10,492 X 0.969 Watts/Sgft
X 3.413 BtuMatt
X 1.000
= 34,706
Occupants 1.00 X 10,492 X 300 Btu/occ.
/ 30 Sqft/occ.
X 1.000
= 104,920
Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt
X 1.000
= 47,984
Process 1.00 X 10,492 X 0.000 Watts/Sgft
X 3.413 Btu/Watt
X 1.000
= 0
Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft
X 3.413 Btu[Watt
X 0.0001
0
Infiltration:[ 1.00 X 1.064 X 10,492 X
9.00 X 0.50 / 60 ]
X 38
= 31,822
Schedule Air Sensible Area
Ceiling Height ACH
AT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
334,934
Sched.
Latent Gain Frac. Area Heat Gain
Btu/hr
Occupants 1.00 X 10,492 X
300 Btuh/occ. / 30
Sgft/occ.
= 104,920
Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413
Btu[Watt
= 0
Process 1.00 X 10,492 X
0.000 Watts/Sgft X 3.413
Btu/Watt
= 0
Infiltration:[ 1.00 X 4,771 X 10,492 X
9.00 X 0.50 /60]
X 0.00394
=E 14,777
Schedule Air Sensible Area
Ceiling Height ACH
AW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
119,697
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14709:15:27 /D:
Page 36 of 41
31
10
C]
ROOM COOLING COIL LOADS
Project Name Date
Tenant Improvement 12/14/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name 2nd Floor Tenant Improvement Time of Peak
Floor Area 10,492.0 ft' Outdoor Dry Bulb Temperature
Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature
Conduction Area U -Value DETD'
R-30 Roof Attic
R-19 Wall
Exist. Single Glazed
Exist. Single Glazed
R-19 Wall
R-19 Wall
Exist. Single Glazed
Exist. Single Glazed
R-19 Wall
1,518.0
1,672.0
432.0
240.0
1,192.0
1,588.0
152.0
60.0
1,288.0
X
X
X
X
X
X
X
X
X
0.0790
X
X
X
X
X
X
X
X
X
61.6
=
=
c
=
=
0
=
=
=
0.0740
37.3
1.1900
24.9
1.1900
24.9
0.0740
39.7
0.0740
44.8
1.1900
24.9
1.1900
24.9
0.0740
58.2
t. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Solar Gain
Window
Window
Window
Window
Window
Window
Window
Window
Window
Orientation
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
Page Total
Area
X
X
X
X
X
X
X
X
X
SGF
X
X
X
X
X
X
X
X
X
SC
X
X
X
X
X
X
X
X
X
Weighting
Factor
=
=
=
_
=
=
_
=
16.0
37
0.864
0.868
24.0
37
0.864
0.868
16.0
37
0.864
0.868
16.0
37
0.864
0.868
24.0
37
0.864
0.868
16.0
37
0.864
0.868
16.0
37
0.864
0.868
24.0
37
0.864
0.868
16.0
37
0.864
0.868
Page Total L
Sched. Weighting
Internal Gain Frac. Area Heat Gain Factor
Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt X 1.000 =
Occupants 1.00 X 10,492 X 300 Btu/occ. / 30 Sgft/OCC. X 1.000 =
Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 =
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 =
Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.0001 =
Aug 3 PM
112 OF
78 OF
Btu/hr
7,384
4,620
12,792
7,106
3, 502
5,263
4,501
1, 777
5,551
52, 495
Btu/hr
440
659
440
440
659
440
440
659
440
4.615
Btu/hr
34,706
104,920
47,984
0
0
Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 /60] X 38 = 31,822
Schedule Air Sensible Area Ceiling Height ACH AT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334.934
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 10,492 X 300 Btuh/OCC. / 30 Sgft/occ. = 104,920
Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0
Infiltration: 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 __ 14,777
Schedule Air Sensible Area Ceiling Height ACH AW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14T09:15:27 /D: Page 37 of 41
•
•
•
ROOM COOLING COIL LOADS
Project Name Date
Tenant Improvement 12/14/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
2nd Floor Tenant Improvement
Time of Peak
Aug 3 PM
Floor Area
10,492.0ft'
Outdoor Dry Bulb Temperature
112 OF
Indoor Dry Bulb Temperature
74 OF
Outdoor Wet Bulb Temperature
78 OF
Conduction
R-30 Floor no Craw/space
Area
1 10,492.01
X
X
X
X
X
X
X
X
X
U -Value
X
X
X
X
X
X
X
X
X
DETD'
=
=
=
=
=
=
=
=
=
0.0330
38.5
=
=
=
=
=
=
=
=
=
16.0
37
0.864
0.868
24.0
37
0.864
0.868
16.0
37
0.864
0.868
16.0
37
0.864
0.868
Page Total
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Solar Gain
Window
Window
Window
Window
Window
Window
Window
Window
Window
Orientation
(N)
(N)
(N)
(N)
(N)
(N)
(E)
(E)
(E)
Btu/hr
13,314
1 13,3141
Area
X
X
X
X
X
X
X
X
X
SGF
X
X
X
X
X
X
X
X
X
SC
X
X
X
X
X
X
X
X
X
Weighting
Factor
=
=
=
=
=
=
=
=
=
16.0
37
0.864
0.868
24.0
37
0.864
0.868
16.0
37
0.864
0.868
16.0
37
0.864
0.868
24.0
37
0.864
0.868
16.01
37
0.864
0.868
24.0
37
0.864
2.057
16.0
37
0.864
2.057
32.0
37
0.864
2.057
Page Total L
Sched. Weighting
Internal Gain Frac. Area Heat Gain Factor
Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt X 1.000 =
Occupants 1.00 X 10,492 X 300 Btu/occ. / 30 Sqft/occ. X 1.000 =
Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 =
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 =
Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.0001 =
Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 /60] X 38 =
Schedule Air Sensible Area Ceiling Height ACH AT
440
659
440
440
659
440
1,562
1,041
2,083
7,762
Btu/hr
34,706
104,920
47,984
0
01
1 31,8221
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 10,492 X 300 Btuh/occ. / 30 Sgft/occ. = 104,920
Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu[Watt = 0
Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /601 X 0.00394 __
Schedule Air Sensible Area Ceiling Height ACH AW
1 14,7771
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14T09:15:27 /D: Page 38 of 41
•
•
ROOM COOLING COIL LOADS
Project Name Date
Tenant Improvement 12/14/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM
Floor Area 10,492.0 ft' Outdoor Dry Bulb Temperature 112 OF
Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 78 OF
Conduction Area U -Value DETD' Btu/hr
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
=
=
=
=
=
=
=
=
=
Weighting
Factor
X 2.057
X 2.057
X 2.057
X 2.057
X 1.107
X 1.107
X 1.107
X 1.107
X 1.107
=
=
=
=
=
=
=
=
=
32.0
37
0.864
16.0
37
0.864
32.0
37
0.864
16.0
37
0.864
16.0
71
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Solar Gain
Window
Window
Window
Window
Window
Window
Window
Window
Window
Orientation
(E)
(E)
(E)
(E)
(S)
(S)
(S)
(S)
(S)
Page Total
Area
X
X
X
X
X
X
X
X
X
SGF
X
X
X
X
X
X
X
X
X
SC
Weighting
Factor
X 2.057
X 2.057
X 2.057
X 2.057
X 1.107
X 1.107
X 1.107
X 1.107
X 1.107
=
=
=
=
=
=
=
=
=
32.0
37
0.864
16.0
37
0.864
32.0
37
0.864
16.0
37
0.864
16.0
71
0.864
24.0
71
0.864
16.0
71
0.864
16.0
71
0.864
24.0
71
0.864
Page Total
71
Btu/hr
2,083
1,041
2,083
1,041
1,086
1,629
1,086
1,086
1,629
12,765,
Sched. Weighting
Internal Gain Frac. Area Heat Gain Factor Btu/hr
Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 BtuIWatt X 1.000 = 34,706
Occupants 1.00 X 10,492 X 300 Btu/OCC. / 30 Sqf /occ. X 1.000 = 104,920
Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 47,984
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 1.000 = 0
Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt X 0.0001 = 0
Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 / 60 X 38 = 31,822
Schedule Air Sensible Area Ceiling Height ACH AT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 10,492 X 300 Btuh/occ. / 30 Sgft/occ. = 104,920
Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0
Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 = 14,777
Schedule Air Sensible Area Ceiling Height ACH AW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697
EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2016-12-14T09:15:27 /D: Page 39 of 41
C7
40
ROOM COOLING COIL LOADS
Date
12/14/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name 2nd Floor Tenant Improvement Time of Peak Aug 3 PM
Floor Area 10,492.0 ft' Outdoor Dry Bulb Temperature 112 OF
Indoor Dry Bulb Temperature 74 OF Outdoor Wet Bulb Temperature 78 OF
Conduction Area U -Value DETD' Btu/hr
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
Page Total 0
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (`) denote conduction through an interior surface to another room.
Solar Gain
Window
Window
Window
Window
Window
Window
Window
Window
Window
Orientation
(S)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
Area
X
X
X
X
X
X
X
X
X
SGF
X
X
X
X
X
X
X
X
X
Sc
X
X
X
X
X
X
X
X
X
Weighting
Factor
=
=
=
=
=
=
=
=
=
16.0
71
0.864
1.107
16.0
71
0.864
1.107
24.0
71
0.864
1.107
16.0
71
0.864
1.107
16.0
71
0.864
1.107
24.01
71
0.864
1.107
16.0
71
0.864
1.107
40.0
71
0.864
1.107
60.0
71
0.864
1.107
Page Total
Btu/hr
1.086
1,086
1,629
1,086
1,086
1,629
1,086
2,716
4,074
15,480
Sched. Weighting
Internal Gain Frac. Area Heat Gain Factor Btu/hr
Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu[Watt X 1.000 = 34,706
Occupants 1.00 X 10,492 X 300 Btu/OCC. / 30 SgtVocc. X 1.000 = 104,920
Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu[Watt X 1.000 = 47,984
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu[Watt X 1.000 = 0
Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu[Watt X 0.0001 0
Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 / 60 ] X 38 —_ 31,822
Schedule Air Sensible Area Ceiling Height ACH AT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 334,934
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 10,492 X 300 Btuh/occ. / 30 SgtVocc. = 104,920
Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt = 0
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu[Watt = 0
Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60] X 0.00394 14,777
Schedule Air Sensible Area Ceiling Height ACH AW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 119,697
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14709:15:27 ID: Page 40 of 41
U
P.J
'ROOM COOLING COIL LOADS
Project Name
Date
Tenant Improvement
12/14/2016
ROOM INFORMATION
DESIGN CONDITIONS
Room Name 2nd Floor Tenant Improvement
Time of Peak
Aug 3 PM
Floor Area 10,492.0 ft'
Outdoor Dry Bulb Temperature
112 OF
Indoor Dry Bulb Temperature 74 OF,
Outdoor Wet Bulb Temperature
78 OF
Conduction Area U -Value DETD'
Btu/hr
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
X X
=
Page
Total
0
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Weighting
Solar Gain Orientation Area SGF SC
Factor
Btu/hr
Window (S) 40.0 X 71 X 0.864 X
1.107 =
2,716
Window (W) 72.0 X 249 X 0.864 X
0.410 =
6,353
X X X
=
X X X
=
X X X
=
X X X
=
X X X
=
X X X
=
X X X
=
Page Total
9,069
Sched.
Weighting
Internal Gain Frac. Area Heat Gain
Factor
Btu/hr
Lights 1.00 X 10,492 X 0.969 Watts/Sgft X 3.413 Btu/Watt
X 1.000
= 34,706
Occupants 1.00 X 10,492 X 300 Btu/occ. / 30 Sgft/occ.
X 1.000
= 104,920
Receptacle 1.00 X 10,492 X 1.340 Watts/Sgft X 3.413 Btu/Watt
X 1.000
= 47,984
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt
X 1.000
= 0
Process Lighting 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413 Btu/Watt
X 0.000
= 0
Infiltration:[ 1.00 X 1.064 X 10,492 X 9.00 X 0.50 160 ]
X 38
= F 31,822
Schedule Air Sensible Area Ceiling Height ACH
AT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
334,934
Sched.
Latent Gain Frac. Area Heat Gain
Btu/hr
Occupants 1.00 X 10,492 X 300 Btuh/OCC. / 30
Sgft/occ.
= 104,920
Receptacle 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413
Btu/Watt
= 0
Process 1.00 X 10,492 X 0.000 Watts/Sgft X 3.413
Btu/Watt
= 0
Infiltration:[ 1.00 X 4,771 X 10,492 X 9.00 X 0.50 /60]
X 0.00394
__ 14,777
Schedule Air Sensible Area Ceiling Height ACH
AW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
119,697
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-12-14709:15:27 /D:
Page 41 of 41