2006-861I P.O. Boa 1.504 LA QUINTA, CALIFORNIA 92247-15'04 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 December 7, 2006 (.760) 777-7000 FAX (760) 777-7101 Mr. Lon & Lisa Marie Riddle 78-710 Avenida la Torres La Quinta, CA 92253 SUBJECT: MINOR USE PERMIT 2006-861 CASITA; 78-710 AVENIDA LA TORRES Dear Mr. Lon &.Ms. Riddle: Your request for approval of Minor Use Permit 2006-861 allowing the construction of a casita/guesthouse at 78-710 Avenida La Torres; La Quinta, is hereby approved. You may now contact the Building & Safety Department for your building permit. Enclosed is the approved' original Deed Restriction for this Minor Use Permit. It must be signed by the .owner in front of a Notary Public. The original approved documents' are then to be recorded with the County Recorder, with a recorded copy given to the City for, our files. The Community Development Department will sign the job card when the recorded copy is received, which would provide our clearance to the Building & Safety Department to issue the building'final inspection. Until the recorded copy is received by the Community Development Department, your Minor Use Permit is not complete and a final inspection will not be conducted by the Building & Safety Department. ..Should you have any questions, please call me at (760) 777-7125. Sincerely, INNEFRANCO Assistant Planner Attachments c. Builai ty-Dep2gTent-3 r, RECORDING REQUESTED BY: Loh & Lisa Marie Riddle - 78-710 Avenida La Torres La Quinta, CA 92253 WHEN RECORDED PLEASE MAIL TO: 'Mr.. & Ms. Riddle 787710 Avenida La Torres La Quinta, CA 92253 COVENANT AND AGREEMENT RESTRICTING THE USE OF THE RESIDENCE AT 78-710 AVENIDA LA TORRES, LA QUINTA, 92253 ` This Covenant and Agreement are made and executed this 7t" of December by Lon and Lisa Marie Riddle, as the recorded owner(s) of the property described herein. The. City' of La Quinta, a Municipal Corporation, is hereby made a party to this Agreement for the purposes set forth below. The undersigned • hereby certifies that ' he/she is the property owner of the following described real .property in the City .of La Quinta, County of Riverside, State of .California: APN 770-171-013, LOT 152 in the City of La Quinta, County of Riverside, State of California In consideration of the City of La Quinta issuing a .building permit for certain ' improvements which will beconstructed on said property, the undersigned does hereby covenant and agree to, and with said City, to restrict the use of said property as follows: 1. The guest' house may not be rented nor sold independent of the main single family residence (Minor Use Permit No. 2006-861; 2. No kitchen or cooking facilities shall be constructed in the guest house per the provisions of Chapter 9.30.030 (RL Zone District) and 9.60.110 (Guest Houses) of the La Quinta Municipal Code; 3. Al.lon-site facilities are intended for the sole occupancy of the property owner(s), guests, and caretakers (i.e., a maid and/or housekeeper, etc.); and, 4. The guest house shall be used primarily as a sleeping facility, and shall be maintained in accordance with all zoning and other codes as set forth in the La Quinta Municipal Code, as may be amended from time to time. This Covenant and Agreement shall .run with the land and shall be binding upon future owners, their successors, heirs, or assigns, and, ourselves, and shall continue in effect while said accessory'building remains on the real property.or unless otherwise released by the authority of the City of La Quinta. All leases of said dwelling -and/or property shall be subject to this restriction. This Agreement shall be entitled to the remedy of injunctive relief in addition of any remedy in law -or equity. - This Covenant and Agreement and the provisions hereof are .irrevocable, except by the written consent of all parties to the agreement, including the City, ofla Quinta, a Municipal. Corporation. - The City shall have the right to enforce each and every provision- hereof andthe parties agree. that the Agreement shall not be rescinded, revoked, modified, .or otherwise amended or changed, without the expressed written consent of the City first being.obtained. In the event that the owners, their heirs, assigns or, successors in interest, shall fail to perform any obligation hereunder, theyhereby agree to pay all costs. and expenses incurred by the City of. La Quinta in securing performance of such obligation, . including attorney's fees. By: 1. 2.' 3 Signature(s) Printed Name.of all owner(s) Date Les Abdson Date Planning Manager . City of La Quinta {'f . ._ . ----�— �e•R.om.eam.1.a��ameame.u..Yyummmm�®1:.1®mut.ma • ' b Ob WO.V mlh0e.®.gym®�eY J®AO m®f m.trmm®bh W d.�ntcv.aDte �. "'-- —_•y EASIINOSHN3H BLOCK WALL Ylpm Oeahvbede WNv..hv'Ym vlq,.'nh.qu�YGm{mcj mmhJJOW ad.pvdlu md. ' v4M1Mv.LmmsmmA.�Igtmwtl4Avoemlhcieiy6ogYoHEw 16 Tom CONDENSER Y .eMmdALn6mA4hcod�Mgml®IIAJ.1)•1109.IA mOJ10A11 (OlC U1 -,m 60 'Vm�bm44hmO�d.emmoGelbeWbJp�GteAsbhp�y.lhm ONCONC PApAD ' SEE DETAR15iET4 .W" NI0J.I.IJ �tl�W�vPAvp.md�.spbvtllNmvNedy'B.romJ109.1i103C -- EXEMNGPOOL EQUIP. CODES i �• .. E10STWO KOOL DECK .... O. mB1CAlID.BUBDPK;CODE(CdC)80.5EGONTHEIBWUSC molwu.tlECNC00EtCHCjBASEDONTIrEmooumc +wi,M"E� JfJ 'S•?}2`d R„J„'....-;f 1 - �CJIIJP.E LCT�RC�AL ON THEi=m _ CODEICEt)B 2=5 CAM. 1,1.ENERGY CODE - ISTING AND ALL OTHER CODES AND OROMNiCES OF THE CITY OF a OUINTA I ' NEW CAS ITAADDITION EJDSn/KJ POOL' - PROJECT DATA ANP 'a OWNER: MR. & MRS. LON RIDDLE . NEYICONC'PAnO 78-710 AVENIDA LA TORRES _ LA OUINTA, CA 92253 1 W%"r�jYr JOB ADDRESS: SAME AS ABOVE . SETBACK — LEGAL: LOT 152 MB 021. / 061 _ ' :.. '. '• DESERT CLUB TRACT .. UNITS .. • . EASTWGCONC PATIO. TANK ". - .. .. APN&: 770-171-013 - . ,— ' ZONING : R—L, . NEWCO SERVICE TOREPtNCE . I DUSTWGM—PSERVICE 1 CONSTR. TYPE:.V-N = LOT SIZE : 11,780 S.F. ' EASTWGGATE - - EXISTING HOUSE : LNABLE : 2,858 S.F. EXISTING RESIDENCE GARAGE: 872S.F, TOTAL :. 3,530 S.F. . i i EJOSTING B HIGH BLOCK WAIL NEW . .. CASI'TA : 465 S.F. - CONDITIONED FLOOR SPACE: 440 &F. " '— NEW TOTAL: 3,995S.F. • LOT COVERAGE- : 34% • - LIST OF DRAWINGS . .. EQSTMCDNCWAuc EASING GATE SHEET NO. 1 SITE PLAN SHEET NO.2 : FLOOR PLAN �-- EXTERIOR ELEVATIONS _ EASTING DRNEWAY� ROOF PLAN , BLDG SECTION' SHEET NO. 3 : CEILING / LIGHTING PLAN ELEC / MECH PLAN -- WASTE/VENT ISO . . • FOUNDATION PLAN / DETAILS . . FRAMING PLAN / DETAILS _ SHEET NO.4 : GENERAL NOTES EXL4IwG ROLL CURB ' SHEET NO. 5 : TITLE 24 ENERGY CALCS c - - I4amllms•AOtrryu!'�A01W®ms0e.o4dWJC ml4po,edb OVBm1Fg0@o4 Wv hm00ma0elm' ' LATORRES AVENIDA SITE PLAN .. SCALE 1/8 = 14r ' ' NORTH `11/03/2006 FRI 15:34 FAX 760 777 7155. City •of La' Quinta Pub, Wk *;- 001%004 " CITY .OF LA QUYNTA - PUBLIC WORKS/ENGINEERING DEPARTMENT GREEN SHEET (PUBLIC WORKS CLEARANCE) FOR..BUILDING PERMITS Form updated & effective 8RM895 Please DO NOT, submit the Green Sheet (Public Works Clearance) Paeket to the Public.. ' Works/Engineering Department- until ALL requirements listed below• .are complete; Incomplete applications or applications which cannot be processed will be returned to Applicant. • Green Sheet . approvals will be forwaided to the Building Department directly by Public Works. • Date: Developer: Tract No.,a oz4 I -0,6)L Tract Name: 17z25 CL, Lot No.(s), / `' Address(s):_ l G� Td t G.� Qty/nlTi� ' The' following are the requirements for Public, Works Clearance to•authorize, issuance •of -a building . permit from the Building/Safety Department, CUST M HOMES: PROVIDE ITEMS #2 S B•1cLOW:: ; TRACT DOMES: PROVIDE ITTMS #1 #2.113,#44 ASA E AND #6 RENON*: . COMMERCIAL BUILDINGS /dTHER• PROVIDE ITEMS1.t2. 43 AND #5 B . LOVV 1. Attach Pad Elevation Certificates in compliance with .the .approved design'elevation "fore building pad (mam ximuallowable deviation of +/- 0.1. foot). Pad Elevation. CerEificates mustbe current (within 6 months of current date). If a precise grading plan cieates • the• .pad for approval, please withhold green sheet submittal until 'a Pad Elevation. Certificate.' can be :Provided. 2.. Attach geotechnical certification of grading plan compliance. ►: 3. At orded final map showing proposed building locations are legal lots: 4,,. -Attach a completed •<l acre per lot'or infill project Fugitive Dust Control'p;okcct• information - form, PM10.plan & agreennent or provide alternative ,& valid City approved PM10 plan set' referencenumber or hard copy plan. PM10 plans for commercial and residential 4,eve'lopments (beyond 1 lot) are submitted separately with grading plans and are subjeO.:o additional requirements. 5.. Attach an approvedprecise, grading plan for the wbuilding location(s). 'AO: 'flood •- ion e. ' . developments will require an approved flood plain development plant. ,6. Attach an approved rough grading plan for the building location(s). I have reviewed and confirmed the requirements listed ve as•presented and find the irnprovements,. to be sufficiently complete for c ctlgn of he o osed buildings)/structure(s)• on the subject lot(s).. Pursuant tomy •t abo roj m b released for building' ifyAuancie. . ..6Recommended by: Dated: f r Declined for approval,for reason(s) as follow(s), please correct`ati nd resubmit: t 'r:WWDF MAFFCWWc%Ch6MSDmPWR&kft2bS0e 4GRUNSHMCovW&G' • 'i , 11/'x3/2406 FRI 15.34 FAX 760:.777 7155 City of La. Quinta Pub. Wk - f� 002/004 :, Obc of La Ouinta - X10 Project Information (<1 acre per Lot or Infill Project)` 01e 1 of 3 l:orm updated & effective MR2005 4-:: �+ • Project Information Project Contractor. ... t Project Phase Project Phase Project Name: . (Check One); Project Tract , . RConstruction Number: ❑ Demolition ,Lot Number(s);' Anticipated StartDate: aZ Oo '7 Project Street Anticipated Completion, Address: /) --Total acres in active � construction (<1 ,acre per • Lot):. Project Contact Please Note: Dust contml is required 24 hours a day,1 days a week,- Information regardless of construction status. Person listed below is responsible for dust control d business and non- business hours. , Name:let !x'' Title: - o ComBany Name: , -Mailing Address: 7,q _:.7 !o .Cit L�- - State: Zip Code: - ` - - Primary Telephone 60 j i5 �— ',75'1 '% 7 r - Number: • ' . Fax: 7.6®� �6 — �1 J 24 H46ur Aeces e Y .� Phone: , Cell Phone: Aha — /3 — PM10 Certificate Number • " Expanded PM 10 plans for commercial and residential developments > 1 acre are required.by the ` City of La Quinta.. t 7:VwWrSTAFf�Gomer. slw fw RdeweAsnum"I Pa ic►Aawrapsm siuma e 11/93/2006 FRI 1505 FAX 760 777 7155 City of. La• Quinta PubAk 2003/004 PM 10 (51 acre trer Lot or Infill Project) Fugitive Dust Control flan .page 2 of 3 t . Plah updated & Methve 8/2512005 ' This plats shall take into account applicable SCAQMD Rule 403 regulations. Training may be obtained by - contacting SCAQMD (Sharon Zamora (909) 396-2183). This plan shall consist of the following action items: • WATERIN : Continuous watering is required to prevent dust. and must occur a i1inital n of 4 t times daily. Water shall be applied to dry ry soils to stop: , } • Visible dust emissions over 20% opacity • Visible'dust emissions that travel over 100 feet. " �` • Water source % inch water meter at front (south) side of pad: • EDUCATION: Responsible Dust Control 'Individual and key • personnel shall attend SCAQMD PM108class,and obtain PM 10 certificate number prior to construction activiiy..k •. ATHICR MO RING: Wind predictions shall be monitored , SIGNAGE: Use Coachella Valley Fugitive Dust Control Plan•Handbook Construe on Site.Sigtiage ' 4 • Cnridelines. TRAMC- Construction traffic 'shall.not be allowed on the,pad, unless absolutely necessary: >f F vehicles operate on pad, pad shall -be kept firm and moist through-hose watering, or sprinkler'.- Fugitive prinklers:Fugitive Dust shall be prevented by fencing off site to prevent unauthorized traffic pad., 105, mph maximum traffic speed). PARKING: Parking is not allowed on.the pad:. 'All vehicles must park on street (at designated areas . , - 'only). - • TRACK OUT: Provide14 hour streefelcanmi 'l; and track out system as.approvcd by City Public Works Inspector. (No dirt on public or private roads). Track out shall bc'eleaned.up within one hour of incident. • DIRT PILES: Dirt piles shall be litiuted to 50 cubic yards and built per California. Building Code grading requirements, Piles shall be kept moist,or covered with tarp material. Laiger'ditt piles will, require stockpile or grading permit Mgl�& Provide PM10 fencing at perimeter of public voids and. where applicable: •Wiood'.slat fencing can be- installed -at rear of property and return 20' feet on either side if HOA restrictions apply. Block walls can replace PM101encing during the construction phase.,. - • - EMPMENT:'Extra hoses and sprinklers shall be maintained on site. s_• - EXCAVA'I1MMP.ASURES: All areas to be excavated or &ded shall be pre-watered. Water shall ,be applied during excavation or grading operations.also.. • DUMP TRUCKS: Open top duimp trucks to be wet down, moist and.tarped prior to leaving site... • INA SITE: Within 10 days of ceasing of activities, re-vegetatc or permanently stabilize as required. . , ' La:V Vr eV V V a.f\a ­VV V A {.4 1 VV 1 1 1 1 aVV VA VAI V1 LN Q4144VV/ A VIV / 1`111 t r t1 V VIr VVI ' City ofLa Quinta - Site Specific Construction phase PM 10' Agreement Page 3 of 3 • .Agreement U144ted & effective 8125/2005 The signature of•the property owner (or authorized representative) Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to AQMD Rules 403 and 403.1; , • Shall constitute and agreement to comply with all project conditions as identified uii the approved dust-control plan; The property owner (or authorized representative): Acknowledges that dust control is required14 hours a day, 7 days a week, throughout the µ period of project performance, regardless of project size or.status; -Shall ''ensure that, tach and every contractor/subcontractor and,all other persons; as'soeiated ; . with the project shall be in continuous compliance with all requirements of the approved dust control plan; ;� r , _ • Shall take all necessary•precautions -to minimize dust, even if additional measures beyond- - those listed in the dust control plan are necessary; ` Shall authorize• representative of the GWCounty to enter upon the above mentioned.property T for inspection- and/or abatement purposes; and �r • Shall hold harmless the City/Cout►ty and its representatives from liability for any actions related to this dust control plan•or any City/County'initiated abatement activities: r Signat pikrProperty Owner or Authorized • Representative Printed Name r r Title, Date Company, y _ r CERTIFICATE OF COMPLIANCE:.REP4% ENTIAL COMPUTER METHOD CF -1R Page 1' Project Title... Riddle Casita Date..12/15/05 03:23:04 Project Address....._.. 76710 Avenida la Torres ******* ----------- ----------- La .Quinta *v7.10* r Documentation Author... David.McKinley ******* � Building Permit # McKinley Engineering { 608 Hilo Way �. Plan Check / Date .� Vista, CA 92081_ 760-414-1992 I Field Check/ Date I Climate Zone..... .... 15 ---------- --- ----Compliance Method....... MICROPAS7+v7.10.for 2005, Standards by 'Enercomp, Inc. MICROPAS7 v7.10 File -RIDDLE Wth-CTZ15S05 Program -FORM CF -1R User#-MP1707 User -McKinley Engineering Run -Riddle Casita = MICROPAS7 ENERGY USE SUMMARY ---------------------------- Energy -------------------------F-Energy Use ,,§tandard, Proposed Compliance = (kTDV/sf-yr) ! Design Design Margin = Space Heating......... 3.47 3.33 0.14 = 'Space Cooling...... 114.93 115.62 + -0.69 = Water Heating.......... 35.24 .34.67 0,57 Total 153.•64 153.62 0.02 *** Building complies with Computer Performance *** HERS Verification Required -for Compliance _____________________________________________ ` GENERAL INFORMATION -------------------- HERS Verification ........... Required Conditioned Floor Area..... 440 sf Building Type .............. Single Family Detached Construction Type .......:. New Fuel Type ..............:.. NaturalGas Building Front Orientation. Front. Facing 135 deg (SE) Number of Dwelling,Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... S1'ab On Grade','. Number of Building Zones..Q60 Conditioned•Volume........Slab-On-Grade•Area... Glazing Percentage.......ffloor area Average Glazing U-factor../hr-sf-F Average Glazing SHGC....... 0.39 Average Ceiling Height..... 9.7 ft CITY OF.LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE4 BY#__ CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 2 Project Title.......... Riddle Casita Date..12/15/05 03:23:04 ------------------ ------ ------------------ MICROPAS7 v7.10 File -RIDDLE Wth-CTZ15S05 Program -FORM CF -1R User)#-MP1707 User -McKinley Engineering Run -Riddle Casita ------------------------------------------------------------------------------- BUILDING ZONE INFORMATION ------------------------- Floor ## of ## of Cond— Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf). Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ----- ------- ---------- Residence 440 4260 1.00 4.0 Yes Setback 2.0 Standard No OPAQUE SURFACES FENESTRATION SURFACES --------------------- Exterior Area U- Act Shide Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ 1 Wind Front (SE) 80.0 0.570 0.390 135 90 Standard ADOOR/Metal Operable'.Low 2 Wind Left (W) 16.0 0.570 0.390 270 90 Standard F4040/Metal Operable Low 3'Wind Back (N) 16.0 0.570 0.390 0 90 Standard G4040/Metal Operable Low 4 Wind Back (N) 8.0 0.570 0.390 0 90 Standard G4020/Metal Operable Low . U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or 4-X4 -val Azm Tilt d Reference Comments ------------ -=--- ---- 1 ----- ----- ----- --- ---- --- --------- -------------- 1 Wall Wood 60 0.102 13 0 135 90 Yes IV.9 A3 2 Wall Wood 70 0.102 13 0 90 90 Yes IV.9 A3 3 Wall Wood 60 0.102 13 0 180 90 Yes IV.9 A3 4 Wall Wood 70 0.102 13 0 270 90 No IV.9 A3 5 Wall Wood 50 0.102 13 0 180 90 No IV.9 A3 6 Wall Wood 189 0.102 13 0 270 90 Yes IV.9 A3 7 Wall Wood 251 0.102 13 0 0 90 Yes IV.9 A3 8 Wall Wood 93 0.102 13 0 90 90 Yes IV.9 A3 9 Door None 17 0:330 0 0 90 90 Yes None 10 Wall Wood 70 0.102 13 0 180 90 Yes IV.9 A3 11 Roof Wood 167 0.026 38 0 135. 23 Yes IV.1 A8 12 Roof Wood 114 0.026 38 0 135 23 Yes IV.1 A8 PERIMETER LOSSES. ---------------- Appendix Length . F2 Instil Solar IV Location/ Surface ------------ (ft) ------ Factor R-val Gains Reference Comments 13 S1abEdge 93 -------- 0.760 ------- R-0 ----- No --------- None ----- ---------------- 14 S1abEdge 12 0.510 R-0 No None FENESTRATION SURFACES --------------------- Exterior Area U- Act Shide Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ 1 Wind Front (SE) 80.0 0.570 0.390 135 90 Standard ADOOR/Metal Operable'.Low 2 Wind Left (W) 16.0 0.570 0.390 270 90 Standard F4040/Metal Operable Low 3'Wind Back (N) 16.0 0.570 0.390 0 90 Standard G4040/Metal Operable Low 4 Wind Back (N) 8.0 0.570 0.390 0 90 Standard G4020/Metal Operable Low M CERTIFICATE OF COMPLIANCE: RESIDENTIAL, COMPUTER METHOD •CF'-IR Page 3 Project Title.......... Riddle Casita Date..12/15/05.03:23:04. MICROPAS7 v7.10 File-RIDDLE Wth-CTZ15S05 Program-FORM CF-1R User#-MP1707 User-McKinley Engineering Run-Riddle Casita ------------------------------------------------------------------------------- OVERHANGS ---Window--- ------------Overhang------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension 1 Window 80.0 8 10 .2 0 n/a. n/a THERMAL MASS ------------ Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity UIMC•R-value Location/Comments ---- ---- --- --'-.- -----_ -___- ;r6...7.---____. __^_�--� --- -___------------------ 1 S1abOnGrade 390. 3.5 28.0 0.98 4.60 R-0.0 2 S1abOnGrade 50 3.5 28.0 -0.98 1.80 .R-2..0 HVAC SYSTEMS ------------ Verified Number. Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate_Fan Watt Cooling Type Systems Efficiency EER or TXV, Airflow Draw Capacity HPSplit 1 8:00 HSPF n/a n/a n/a n/a n/a ACSplit 1 13.00 SEER 11.0 Yes No No No HVAC SIZING Verified Total. Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) (Btu/hr) (Btu/hr) -(Btu/hr) HPSplit 14919 n/a n/a n/a ACSplit n/a 13032 16173 n/a Sizing Location............ LA QUINTA Winter Outside Design....... 26 F Winter Inside Design....:.. 70 F *Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range........... .. 34 F M CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD----------CF'-1R----Page 4 Project Title Riddle Casita Date..12/15/05 03:23:04 MICROPAS7 v7.10 File -RIDDLE Wth-CTZ15S05 Program -FORM CF -1R User#.7MP1707 User -McKinley Engineering Run -Riddle Casita ------------------------------------------------------------------------------ SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a HERS verified Refrigerant Charge -test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This building incorporates HERS verified non-standard Duct Location. This building incorporates a High Mass Design. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home. energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF -4R installation certificate: *** This building incorporates a HE verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified SER. DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location, R -value Leakage ------- Area -------- Ducts --------- ------------- HPSplit ------------------ 12InOther R-4.2 Yes No No ACSplit 12InOther R-4.2 Yes No No WATER HEATING SYSTEMS --------------------- Number Tank External Heater •� -�� - -in':!' Energy Size Insulation Tank Type Type f, Distribution Type System ------ Factor -------- (gal) ------ R -value ---------- ---------------- -------- 1 Storage Gas ------------------- Standard 1 0.58 50 R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a HERS verified Refrigerant Charge -test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This building incorporates HERS verified non-standard Duct Location. This building incorporates a High Mass Design. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home. energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF -4R installation certificate: *** This building incorporates a HE verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified SER. .CERTIFICATE OF'COMPLIANCE: RESIDENTIAL COMPUTER METHOD, CF -1R Page 5 Project Title.......... Riddle Casita Date..12/15/05 03:23:04. MICROPAS7 v7.10 File -RIDDLE Wth-CTZ15S05 Program -FORM CF -1R User#-MP1707 User -McKinley Engineering Run -Riddle Casita HERS REQUIRED VERIFICATION This building incorporates HERS.`verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. If the measured. CFM is above the target, then corrective action must. be taken to reduce the duct leakage and a then must be. retested. Alternatively, the compliance calculations could be = redone without duct testing. If ducts are not installed, then HERS verification is not necessary. This building incorporates,HERS verified non-standard Duct Location. REMARKS 'COMPLIANCE STATEMENT, ----------------- -- This certificate of compliance lists the b-dilding features and performance specifications needed to comply with Title -24, Parts 1 and 6 of . the ,. California Code of Regulations, and, the administrative regulations to implement them. This 'certificate has-been signed by the. individual with ;. overall design responsibility. a DESIGNER or OWNER DOCUMENTATION,AUTHOR r Name.... Kripa Kripanarayanan ' Name.... David'McKinley Company. Concorde Consulting Company. McKinley Engineering Address. 3505 Cam. del Rio S. #350 Address. 608 Hilo Way San Diego, CA. 92108 Vista, CA 92081 Phone... 610 516'3377 Phone._ 760-414=1992 License. , .Signed.. Signed.. ri, �n� 12/15/,05 (date) N• '(date) ENFORCEMENT AGENCY k� Title... Agency.. <: Phone... Signed.. (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R Page 1 ---------------------------------- Project Title.......... Riddle Casita Date..12/15/05 03:23:04 Project Address........ 78710 Avenida la Torres ******* --------------------- La•Quinta *v7.10* Documentation Author... David McKinley ******* Building Permit # McKinley Engineering 608 Hilo Way Plan Check / Date Vista, CA 92081 760-414-1992 Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. MICROPAS7 v7.10 File -RIDDLE Wth-CTZ15S05 Program -FORM MF -1R User#-MP1707 User -McKinley Engineering Run -Riddle Casita ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this chep},)gk t -is incorporated' into the permit documents, the features noted shall ie considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U -factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R -Value X *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor X 150(e): Installation of Fireplaces, -Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox X b. Outside air intake with damper and control, flue damper and control X 2. No continuous burning gas pilot lights allowed X 150(f): Air retarding wrap installed to.comply with Sec. 151 meets requirements specified in ACM Residential'Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): .Slab edge insulation - water absorption rate for the _X_ insulation material without facings no -greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch _X 118: Insulation specified or installed meets insulation quality_ standards. Indicate type and include CF -6R form 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration..products (except field -fabricated) have X X X X C� MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R Page 2 Project Title.......... Riddle Casita Date..12/15/05 03:23:04 MICROPAS7 v7.10 File -RIDDLE Wth-CTZ15S05 Program -FORM MF -1R User#-MP1707 User -McKinley Engineering Run -Riddle Casita ------------------------------------------------------------------------------- label with certified U -factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification _X_ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked. and sealed X SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES - De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by. the Energy Commission X' 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA.or ACCA X 15.0(i): Setback thermostat on all applicable heating and/or cooling systems „ ._�, .a X 150(j): Water system pipe .and.tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater X . 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R -value X_ 3. The following piping is insulated according to Table 150-_A/B... or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water.pipes closest to water heater tank, non -recirculating -systems., and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B X 2. Cooling system piping (suction, chilled water, ;or brine lines), piping insulated between heating source. , and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A X_ 4. Steam hydronic heating systems or hot water systems >15 psi,' meet requirements of Table 123-A _X_ 5. Insulation must be protected from damage, including that due to sunlight, moisture,.equipment'maintenance and wind X 6. Insulation for chilled water piping and refrigerant suction piping includes a.vapor retardant or is enclosed entirely in conditioned space 7. Solar water-heating-systems/collectors are certified by the Solar Rating and Certification Corporation _X_ *150(m).: Ducts and Fans: 1. All ducts -and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181; M MANDATORY"MEASURES CHECKLIST: RESIDENTIAL MF -1R Page 3 - --------------------------- Project Title.......... Riddle Casita Date..12/15/05 03:23:04 MICROPAS7 v7.10 File -RIDDLE Wth-CTZ15S05 Program -FORM MF -1R User#-MP1707 User -McKinley Engineering Run -Riddle Casita ---------------------7--------------------------------------------------------- UL 1B1A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used X 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts X 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such. t,a;i„s..,used in combination with mastic and draw bands(* X 4. Exhaust fan systems have back draft or automatic dampers—X_ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers X 6. Protection.of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material X 7. Flexible ducts cannot have porous inner.cores X 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of _. the heater, weatherproof operating instructions, no electric resistance heating and no pilot light X 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating b. Cover for outdoor pools or outdoor spas. X 3. Pool system has directional inlets and a circulation pump time switch _X 115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) X 118(i): Cool Roof material meets specified criteria X RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R Page 4 ---------------------------------------------- Project Title.......... Riddle Casita Date..12/15/05 03:23:04 MICROPAS7 v7.10 File -RIDDLE Wth-CTZ15S05 Program-FORM'MF-1R User#-MP1707 User -McKinley Engineering Run -Riddle Casita and have an output frequency no less than 20 kHz _X_ 150(k)1: HIGH.EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast _X 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined. in Sec. 130(c), of permanently installed luminaires in kitchens may be in—luminaires—that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires X_ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high ' efficacy luminaires OR are,,cgmbrelled by, an occupant sensor(s) certified to comply with -Section 119(d) that does.not turn on.automatically or -have an always on option _X_ 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high,efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s), that complies with Section 119(d) that does not turn on automatically or have an always on option .X 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals _X 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to'other buildings on _ the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features br other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified`to comply with Section 119(d) _X_ _150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130,•131, and 146 X_ 150(k)8: Permanently installed lighting in the'enclosed,, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensors) certified to comply with Section 119(d) _X— HVAC SIZING HVAC Page 1 ---------------------------- -- -------------------- Project Title .......... Riddle Casita Date..12/15/05 03:23:04 Project Address........ 78710 Avenida la Torres ******* --------------------- La" Quinta• *v7.10* Documentation Author....David McKinley ******* Building Permit # McKinley Engineering 608 Hilo Way Plan Check / Date Vista, CA. 92081 760-414-1992 Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc.. MICROPAS7 v7.10 File -RIDDLE Wth-CTZ15S05 Program -HVAC SIZING User#-MP1747 User -McKinley Engineering Run -Riddle Casita . --------------- ----------------------------------------------------------------- GENERAL INFORMATION -------------- Floor Area ................. Volume. �, r -r- ....... . Front Orientation.......... Sizing Location............ Latitude ................... Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range ............... Interior Shading Used....... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 440 sf 4260 cf Front Facing 135 deg (SE) LA QUINTA 33.8 degrees 26 F 70 F 111 F 75 F 34 F Yes Yes Yes 0.24 HEATING AND COOLING LOAD SUMMARY -------------------------------- Heating Cooling Description ----------- (Btu/hr) (Btu/hr) ----------- --------------------------------- Opaque Conduction and Solar...... 9071 4264 Glazing Conduction and Solar..... 3010 382.6 Infiltration ..................... 1657 958 Internal Gain .................... n/a 2520 Ducts ............................ 1181 1464 ----------- ----------- Sensible Load .................... 14919 13032 Latent Load ...................... n/a .3141 Minimum Total Load ----------- 14919 ----------- 16173 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. TITLE 24 REPORT Title 24 Report_ for: Riddle Residence 78-710 Avenida La Torres La Quinta, CA . JS %X Project Designer: Report Prepared By: Joan D. Hacker Insu-form, Inc. A 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 (760) 779-0657 CITY OF LA QUINTA Job Number: BUILDING & SAFETY DEPT. APPROVED -j-3 °U zA FOR CONSTRUCTION � oat DATEDate: � ,BY . 9/15/2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.1 by EnergySoft Job Number: User Number: 2655 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary7 HVAC System Heating and Cooling Loads Summary g Room Load Summary 11 Form ECON-1 Energy Use and Cost Summary 13 EnergyPro 4.1 by EnergySoft Job Number. User Number: 2655 Certificate Of Compliance : Residential (Part 1 of 3) CF -1 R Riddle RPsidencP 9/15/2006 Project Title Date 7-8-710_Avenida I a Torres I a Quintal Project Address Building Permit #. Insti-foEm_Inc (760) 779-0657 Documentation Author Telephone Plan Check/Date Fn _ravPro 15 Compliance Method Climate Zone Field Check/Date TDV Energy Use (kBtu/sf-yr) Standard Design Proposed Design Space Heating 4.90 5.76 Space Cooling 103.01 100.50 Fans 14.60 14.34 Domestic Hot Water 8.58 8.58 Pumas 0.00 0.00 Totals 131.08 129.18 Percent better than Standarri- ❑ ❑ Building Type: Single Family ❑ Addition ❑ Multi Family Existing + Add/Alt Building Front Orientation: (S) 180 deg Fuel Type: Natural Gas Fenestration: Area: 420 ft2 Avg. U: 0.84 Ratio: 12.5% Avg. SHGC: 0.70 BUILDING ZONE INFORMATION Zone Name Compliance Margin -0.86 2.50 0.25 .0.00 0.00 1.90 1.4% Total Conditioned Floor Area Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: # of Floor Area Volume Units OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm Zone Type Cnnditinned conditioned Thermostat Type Sethark —S.elbacl� Gains Condition Tilt Y / N Status 1A 1\/ Rcfcrcnrc �t i 3,350 ft2 2,858 ft2 0 ft2 3,350 ft2 8.9 ft 1.00 1 Vent Hgt. Area —nl2 _2 n/a a nd 162 n 1D2 R_13 R-00 1R0 A Wall Wm—d— ----IA3- 0.102 R_n _R -n o 272_90 Call Wood_ 276_ -DA02- B-1 R-Og_Q_90 Ron Wand 190. 0102 R_19 R-00 An _g0 Roof Wood_ - 492 -0 051 R12 F2-0-Q---Jao- 0 Will Woad_ 375 0--U0 - g11 R -O 0 180 qD Dnor None 24 '-D-50- (one -_8=0D_ 1R0g0 W;411 Wnnd 2n -0110--B_]1 &00--225 qn Wall WDud_ SOD_ -0.110 R-11 B -o n—lgp _90 Wall V1/ood_ _46.7 0 110 _R11 [R-o.n 270 q Wa1I Wnnd 17 0 u0_ R-11 �Q0 315 go Wa1I Woad— 560 -0-1]0-- 8_11-R-00 0. .-9D Wall W Qd_ 17 0.110 R-11 R^0 0 45 q Wall Wood _3Dp 0110 R_11 R�00 _Q_g0 Wall )LVO -o -d— —463- -0-=- —R1 1- -0 0 _9-0 _g0 Wall Wood_ 20 0.110 R_11 R -00-_1359D Roof Wnnd 2959 0 049 R_19 R_0� 190 _0 W fy1 VM_\ IN A IN � X rIN IX- IX IX Q � X X ElF-17nne ❑ ❑ ❑New ❑New ❑tlew ❑New ❑New_ ❑Fxict_._-invo_ ❑Rammed- ❑Nlew ❑RemoxesL ❑Ex� ❑New ❑Existing_ LJ ❑Removed ❑Existing ❑New OFxisting ❑ ❑ 09-A3 Additinn 09-A3 Addition 09-A3 Addition 09-A3 Addition 02-A5 Addition D9_A2 Living on 29-A4 Liming Zone 04-A2 Iiving7nne D0 A2 I ivinn 7— i�ting 09-82 ivi g one 09-A2 Living 7nne 09-A7 Iiving7nne New- 09-A2 1 iving 7onQ 09-A2 Living one 09.-A2 I i wing one D9 -A2 01-A4 II iving g Zone ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 9Y Y 9y User Number 2655 yr iaiuo i1:si:u/ Run r: : 1158345067 Ener Pro 4.1 b Ener Soft Job Number: Pane: 3 of 13 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R Riddle Residence 9/15/2006 Project Title Date FENESTRATION SURFACES # Type Area U-Factorl SHGC2 True Cond. Azm. Tilt Stat. Glazing Type Location/ Comments 1 Window Front (_S) 300 0 0 790 116-A n10 116_B 180 -9Q New Double Metal .,ear Addition 2 Window Front (S) 8.0 0.790 116-A 0_70 116-B 180 90 New Double Metal Clear Addition 3 Window Left (W) 20.0 0.790 116-A 0_70 116-B 270 90 New Double Metal Clear Addition 4 Window Left (W) 16.7 0.790 116-A 0_70 116-B 270 90 New Double Metal Clear Addition 5 Window Left (W) 20.0 0.790 116-A 0_70 116-B 270 90 New Double Metal Clear Addition 6 Window Rear (N) 20.0 0.790 116-A 0_70 116-B 0 90 New Double Metal Clear Addition Z Window Rear U 4.0 0.790 116-A 0.70 116_B 0 90 New Double Metal Clear Addition 8 Window Right (E) 20.0 0.790 116-A 0.70 116-B 90 90 New Double Metal Clear Addition 9 Window Front U 25.0 0.870 NFRC 0_70 NERC 180 90 Existing Double Mtl Uncoated Default Living Zone 10 Window Front (SW) 10.0 0.870 NFRC 0.70 _NFRC 225 90 Existing Double Mtl Uncoated Default Livinq Zone 11 Window Left (W) 33.4 0.870 NFRC 0_70 NFRC 270 90 Existing Double Mtl Uncoated Default Living Zone 12 Window Left (NW) 13.3 0.870 NFRC 0_70 NFRC 315 90 Existinq Double Mtl Uncoated Default Living Zone 10 14 Window Window Rear Rear (N) (N) 32.0 0.870 NFRC-02D NFRC 0 33.4 0.870 NFRC 0070 NFRC 0 -NExisting Double MtLUncoatedJaefa_ult- LovIng on . 90 Existing Double Mtl Uncoated Default Living Zone 15 Window Rear (N) 14.0 0.870 NFRC 0.70 NFRC 0 90 Existing Double Mtl Uncoated Default Living Zone 16 Window Rear (N) 33.4 0.870 NFRC 0_70 NFRC 0 90 Existing Double Mtl Uncoated Default Living Zone 17 Window Rear (N) 26.7 0.870 NFRC 0_70 NFRC:. 0 90 Existing Double Mtl Uncoated Default Living Zone 18 Window Rear (N) 33.4 0.870 NFRC 0_70 NFRC 0 90 RemovedDouble Mtl Uncoated Default Living Zone 19 Window Rear (N) 20.0 0.870NFRQ 0.70 NFRC 0 90 RemoveclDouble Mtl Uncoated Default Living Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhanq # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. 1 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 1.0 8.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 6.8 2.8 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 5 0 4.0 2.0 0 1 2.0 2.0 7 Bug Screen 0.76 1.0 4.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 1.0 1.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 6.8 5.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 4.0 8.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 6.8 2.5 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 3.5 4.0 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 6.8 5.0 2.0 0.1 2.0 2.0 17 Bug Screen 0.76 6.8 2.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 6.8 5.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 9.0 8.0 2.0 0.1 2.0 2.0 Left Fin Dist. Len. THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Right Fin Dist. Len. Hqt. PERIMETER LOSSES Type Length Insulation R -Val. Location JA IV Reference Condition Status Location/ Comments Slab Perimeter 18 None No Insulation 26-A1 New Addition Slab Perimeter 35 None No Insulation 26-A1 Existing Living Zone Run Initiation Time: 09/15/06 11:31:07 Run Code: 1158345067 EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:4 of 13 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R Riddle Residence 9/15/2006 Protect Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHIS Azm. Tilt Stat. Glazing Type Comments 20 Window Rear (NF,)13 3 _0 87O NFRC -Q10 NERC 45_ _90 xictino Double Mtl Uncoated Default I Mog Zone 21 Window Right (E) 20.0 0.870 NFRC 0_70 NFRC 90 90 Existing Double Mtl Uncoated Default Living Zone 22 Window Right (E) 16.7 0.870 NFRC 0_70 NFRC 90 90 RemovedDouble Mtl Uncoated Default Living Zone 23 Window Right (E) 9.0 0.870 NFRC 0_70 NFRC 90 90 Existing Double Mtl Uncoated Default Living Zone 24 Window Right (E) 8.0 0.870 NFRC 0_70 NFRC 90 90 Existing Double Mtl Uncoated Default Living Zone 25 Window Right (SE) 10.0 0.870 NFRC 0_70 NFRC 135 90 Existing Double Mtl Uncoated Default Living Zone 4.0 2.0 0.1 2.0 2.0 25 Bug Screen 0.76 5 0 2.0 2.0 0.1 2.0 2.0 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd Len. Hgt LExt RExt Dist Len Hgt Dist Len Hgt 20 Bug,Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 Ti Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 22 Bug Screen 0.76 6.8 2.0 2.0 0.12.0 2.0 23 Bu q Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 24 Bug Screen 0.76 2.0 4.0 2.0 0.1 2.0 2.0 25 Bug Screen 0.76 5 0 2.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Type Length R -Val. Location JA IV Reference Condition Location/ Status Comments Run Initiation Time: 09/15/06 11.31.07 Run Code: 1158345067 EnergyPro 4.1 by Energysoft User Number: 2655 Job Number: Page:5 of 13 Certificate Of Compliance : Residential (Part 3 of 3) CF -1 R Riddle Residence 9/15/2006 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Addition Packaqed Heat Pump 7.00 HSPF Packaged Heat Pump 13.0 SEER New Setback Living Zone Central Furnace 78% AFUE Packaged Air Conditioner 9.0 SEER Existing Setback HVAC DISTRIBUTION Location Heati Addition Ducted Living Zone Ducted Hydronic Piping Pipe . Pipe Insul. System Name Length. Diameter Thick. Duct Condition Ducts R -Value Status Tested? 4.2 47 New No Existing No WATER HEATING SYSTEMS Rated Duct Cooling Location Ducted Outdoors Ducted Attic Hydronic Piping Pipe . Pipe Insul. System Name Length. Diameter Thick. Duct Condition Ducts R -Value Status Tested? 4.2 47 New No Existing No WATER HEATING SYSTEMS Rated Tank Energy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 Existing 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Control # HP Hot Water Piping Length (ft) Add 1/2" In Plenum Outside Buried Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner -; &(peer Business & Professions Code) Name: '/ a(--- X17 Title/Firm: /19 S 010 Address:c%> 11 S- - 5 -h 0 y Du ICS 10e s c4- 'TZzQy Telephone: 7)(60 3 10 - (2 1 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone Documentation Author Name: Joan D. Hacker Title/Firm: Insu-form, Inc. Address: 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 Telephone: (760) 779-0657 OU (sig n) (date) (signature/stamp) (date) EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Paae:6 of 13 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not applicable. ENFORCE - Building Envelope Measures N/A DESIGNER MENT 9 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ Fx_1 ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ El El § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ElElapply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ a ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ a ❑ § 150(f): Air retarding wrap installed to comply witt§ 151 meets requirements specified in the ACM Residential Manual. ❑ Q ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include CF -6R Form: ❑ ❑ ❑ § 116-1.7: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ Q ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ O ❑ .3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning,. Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ 0 - ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ EX -1 ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ O ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance ❑ ❑ of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation and indicated the ❑ ❑X ❑ on exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B. ❑ ❑X ❑ 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B ❑ Q ❑ and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ Q ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment El ❑ maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space. ❑ ❑ ❑ 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ iergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:7 of 13 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,❑ X❑ ❑ reductions in the cross-sectional area of the ducts. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ © ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ 0 ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). 4. Exhaust fan systems have back draft or automatic dampers. ❑ © ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ El ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ © ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,❑ X❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ 0 ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section fl 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ . certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ 0 ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:8 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Riddle Residence 9/15/2006 SYSTEM NAME FLOOR AREA Addition 492 ENGINEERING CHECKS SYSTEM LOAD Number of Systems COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 47,500 Total Room Loads 993 15,631 1,307 309 11.,810 Total Output (Btuh) 47,500 Return Vented Lighting 0 Output (Btuh/sqft) 96.5 Return Air Ducts 2,780 1,345 Cooling System Return Fan 0 0 Output per System 46,000 Ventilation 0 0 0 0 0 Total Output (Btuh) 46,000 Supply Fan 0 0 Total Output (Tons) 3.8 Supply Air Ducts 2,780 1,345 Total Output (Btuh/sgft) 93.5 TOTAL SYSTEM LOAD 21.19 1 307 14 500 Total Output (sgft/Ton) 128.3 Air System HVAC EQUIPMENT SELECTION CFM per System 1,600 Airflow (cfm) 1,600 Carrier48HJ?005--(5/6)2 30,740 11,562 29,667 Airflow (cfm/sgft) 3.251 10.0 kW Supplemental Electric 34,130 Airflow (cfm/Ton) 417.4 Outside Air(%) 0 0-01 Total Adjusted System Output 30,740 11,562 63,797 (Adjusted for Peak Design Conditions) Outside Air (cfm/sqft) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.2 of 69.2 of 86.6 OF 9= 106.7 of FW Supply Air Ducts Outside Air '� �� 0 cfm ` Supply Fan Heating Coil Aux. Heat Coil 105.9 OF 1600 cfm ROOMS of 70.0 OF 69.2 Return Air Ducts I OOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 of 79.6 66.7 of 79.6 / 66.8 of 61.6 / 60.5 of Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 63.2 / 61.1 OF 1600 cfm ROOMS 54.3% R.H. 79.6 / 66.7 of 78.0 / 66.2 of Return Air Ducts ` I tnergyrro 4.1 by Energysoft User Number: 2655 Job Number: Page:9 of 13 IHVA:C SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Riddle Residence 9/15/2006 SYSTEM NAME FLOOR AREA Living Zone 2 858 ENGINEERING CHECKS ISYSTEM LOAD Number of Systems 1 Heating System Output per System 70,000 Total Output (Btuh) I 70,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM ISensible Latent I CFM I Sensible Total Adjusted System Output (Adjusted for Peak Design Conditions) 3,978 39,769 3,743 1,439 38,420 0 7,993 5,504 0 0 0 0 0 0 0 0 0 7,993 5,504 55,7561 3,7431 49 428 Existing 38,079 19,913 Total Adjusted System Output (Adjusted for Peak Design Conditions) 38,079 19,913 70,000 70,000 TIME OF SYSTEM PEAK I Aug 2 1 Jan 12 am :ATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26.0 OF 67.7 OF 97.4 OF 97.4 of Supply Air Ducts Outside Air Q 7T 0 cfm 95.1 °F Heating Coil Supply Fan 2210 cfm ROOMS 67.7 OF 70.0 OF Return Air Ducts I COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) 11.0 / 77.6 OF Outside Air 0 cfm 81.4/69.7 °F 81.4/69.8°F M 65.2/64.3°F 65.2/64.3°F Cooling Coil *` Supply Air Ducts Supply Fan 68.6 / 65.3 OF 2210 cfm 63.1% R.H. ROOMS 78.0 / 68.7 OF Return Air Ducts EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:10 of 13 IR'odm LOAD SUMMARY PROJECT NAME DATE Riddle Residence 9/15/2006 SYSTEM NAME FLOOR AREA Addition 492 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLEi307 NT CFM SENSIBLE LATENT CFM SENSIBLE Addition Addition 1 993 15,631 993 15,631 1,307 309 11,810 PAGE TOTAL 1 993 15,631 1,307 309 11,810 TOTAL 1 993 15,631 1,307 309 11,810 EnergyPro By EnergySoft User Number: User Job Number: Page: 11 of 13 �ROO'-M LOAD SUMMARY PROJECT NAME DATE Riddle Residence 9/15/2006 SYSTEM NAME FLOOR AREA Livina Zone 1) QrlQ EnergyPro By EnergySoft User Number: User Job Number: Page:12 of 13 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM I SENSIBLE LATENT CFM SENS1 LE LATENT CFM SENSIBLE Living Zone Existing Living 1 3,978 39,769 3,743 3,978 39,769 3,743 1,439 38,420 PAGE TOTAL 3,978 39,769 3,743 1,439 38,420 TOTAL 1 3,978 39,769 F 3,743 1 1,439 38,420 EnergyPro By EnergySoft User Number: User Job Number: Page:12 of 13 ENE1tGY USE AND COST SUMMARY ECON-1 115ROJECT NAME I DATE Riddle Residence Rate: Fuel Tvpe: 9/15/2006 Rate: Fuel Tvpe: STANDARD PROPOSED MARGIN Energy Use (kWh) Peak Demand (kW) Cost ($) Energy Use (kWh) Peak Demand (kW) Cost I ($) Energy Use (kWh) Peak Demand (kW) Cost ($) Jan 124 6 253 2 -129 4 Feb 102 10 154 5 -52 6 Mar 231 8 208 7 23 0 ' A r 8151 13 713 12 101 1 Ma 1,979 21 1,8851 21 93 0 Jun 3,955 21 3,821 21 135 0 Jul 4,579 211 4,507 21 72 0 Au 4,5971 19 4,489 19 108 0 Sep 3,267 22 3,154 22 112 0 Oct 1 1,476 17 1,381 171 951 0 Nov 71 7 105 4 -34 3 Dec 136 51 1 257 4 -121 1 Year 21,3311 22 20,9271 22 404 0 Rate: Fuel Tvpe: The values shown here are based upon the results of an EnergyPro Compliance energy analysis that uses Title 24 profiles as specified in the Residential ACM manual. EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:13 of 13 STANDARD PROPOSED MARGIN Energy Use (therms) Peak Demand (kBtu/hr) Cost ($) Energy Use (therms) Peak Demand (kBtu/hr) Cost ($) Energy Use (therms) Peak Demand (kBtu/hr) Cost ($) Jan 67 83 63 801 4 2 Feb 43 71 41 70 2 1 Mar 34 64 33 64 1 1 Apr 25 7 25 7 0 0 Ma 24 6 241 6 0 0 Jun 22 6 22 6 0 0 Jul 22 6 22 6 0 0 Au 21 5 21 5 0 0 SeD 20 5 20 5 0 0 Oct 22 6 22 6 0 0 Nov 32 58 31 58 1 0 Dec 77 811 1 721 791 5 1 Year 408 83 395 80 131 2 Annual Totals Energy Demand Cost I Cost/sgft I Virtual Rate Electricity 20.927 kWh 22 kW 0 0.00/s ft 0.00/kWh Natural Gas 395therms 80kBtu/hr$ 0$ 0.00/s ft$ 0.00/therm Total $ 0 $ 0.00/sqft The values shown here are based upon the results of an EnergyPro Compliance energy analysis that uses Title 24 profiles as specified in the Residential ACM manual. EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:13 of 13