Loading...
BMCH2016-033578-495 CALLE TAM PICO C� 0 D LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O16-0335 Property Address: 48119 CALLE SERANAS APN: 646110048 Application Description: OSBORNE / CHANGE OUT CONDENSOR Property Zoning: Application Valuation: $6,500.00 Applicant: J ANTHONY PLUMBING HEATING & AIR CONDITI 72216 NORTH SHORE ST 6101 THOUSAND PALMS, CA 92276 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. Licensee CClass- C20 C36 License No.: 777794 Contracto� OWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a' signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and th1w basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the 'building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors 'to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law,). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's VOICE (760) 777-712S FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: ' . CARLOSBORNE 47850 VIA OPERA LA QUINTA, CA 92253 Contractor: J ANTHONY PLUMBI 72216 NORTH SHOF THOUSAND PALMS, (760)328-8096 Llc. No.: 777794 WORKER'S COMPENSATIO I hereby affirm under penalty of perjury one of th I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the wor which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: MIDWEST EMPLOYERS CASUALTY COMPANY Policy Number: Date: 9/7/2016 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 the Labor Code, I shall forthwith comply with those provisions. Date: 7 / Applicnt: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S, FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to ter upon the above-mentioned property for inspection purposes. 01 Signature (Applicant or Agent)761, . {. Date: 9/7/2016 Application Number: BMCH2O16-0335 Owner: ' Property Address: 48119 CALLE SERANAS" CARL OSBORNE APN: 646110048 47850 VIA OPERA Application Description: OSBORNE / CHANGE OUT CONDENSOR LA QUINTA, CA 92253 Property Zoning: Application Valuation: $6,500.00 " Applicant: Contractor: J ANTHONY PLUMBING HEATING & AIR CONDITI J ANTHONY PLUMBING HEATING & AIR CONDITI ,72216 NORTH SHORE ST #101 J 72216 NORTH SHORE ST #101 THOUSAND PALMS, C492276' THOUSAND PALMS, CA 92276 (760)328-8096 i Llc.' No.: 777794 " Detail: HVAC CHANGE OUT.- (1) 14SEER CONDENSORJ2013 ENERGY] CARBON MONOXIDE ALARM(S) TOPE INSTALLED PRIOR TO FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES. FINANCIAL .• !. DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 ' 0. $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - CONDENSER ONLY 101-0000-42402 0 $36.26 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - CONDENSER ONLY PC 101-0000-42600 0 $24.17 . Total Paid -for CHANGEO IT: $60.43 DESCRIPTION ACCOUNT QTY- AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $91.85 Total Paid°for PERMIT ISSUANCE: $91.85 r i Bin # city of La Qulnta Building 8T Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit.# l C�j (� Project Address: t lL° 5¢ P6 Owner's Name: JAN jGf— A. P. Number: Address: Legal Description: Contractor: City, ST, Zip: Telephone: 310 [Yo l— (gam Address: J ANTHONY SERVICES 72916 NORIH SHORE SISTE 101 Project Description: City, ST, Zip: THOUSAND PALMS, CA 92276 .e To N 60 P 0 C rias , Telephone: i^0 2/ 3 Z f State Lic. # : % -777City Lic. C/015 Arch., Engr., Designer: Address: City., ST, Zip: Telephone:hone: '`'<::»:«<<d»::>'»:<:#::<:i:i<i#<i<:?»:>r Construction TY Pe: Occupancy: `State Lic. #: Project type (circle one): New Add'n. Alter Repair Demo Name of Contact Person: Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: el, APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cala. Called Contact Person Plan Check Balance Title 24 Cala. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Ud Review, ready for corrections/issue . Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC) use one MR -ALT -02 document for each dwelling unit. (Page 1 of 3 ) Project Name: OSBORNE Date Prepared:.- 2016-09-07 A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be.documented, use one MR -ALT -02 document for each dwelling unit. 02 01 Project Name OSBORNE • 02 Date Prepared 2016-09-07 09 03 Project Location 48119 CALLE SERANAS 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name OSBORNE 07. Zip Code 92253 08 Dwelling Unit Conditioned 1800 SC System SC System CFA served r �vsystem a Floor Area (ft2) installing new 5 �-� r n' 'a. Iristaling : -Y, m InstallmgInstalling �- Identification or Number of space conditioning by this SC ducted 09 Climate Zone 15 10 (SC) systems in this dwelling 1 Name Served System (ft2) system? component? unit. feet of ducts? duct system? aa 4 i B. Space Conditioning (S.C) System Information.... 0 `'' 01 02 03' 04 05 h tF 06 K % 07 08 } a 09 10 M. -. Is the SC d `Y^3`""zJ €r ':4 " rz Installing a P-1,; MSyt.�.'FK:1W i& : r ii„ TB:t--nu�i` l Vit' I &0 SC System SC System CFA served r �vsystem a a — refrigeant installing new 5 �-� r n' 'a. Iristaling : -Y, m InstallmgInstalling �- Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new: Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 Location 1 1800 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)iDiib) This section does not apply to this project. Registration Number: 216-A0330783A-000000000-0000 Registration Date/Time: 2016-09-07 07:15:09 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 Schema Version: 0.555SDD H Report Generated: �RS Provider: CalCERTS 2016-09-07 07:15:05 CERTIFICATE OF COMPLIANCE ' Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) CF1R-ALT 02-E (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) This section does not apply to this project. 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Altered Cooling Minimum Required New or Identification System Heating . Efficiency _Minimum Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas No heating This field or This field or Central split Outdoor This field or This field or System 1 furnace component section is not section is not AC condensing SEER 14 Setback section is not section is not altered applicable applicable unit applicable applicable Required Documentation: - CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums: R6. CF2R-MCH-20-H & MR -MCH -20-1-1 — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced. -Leakage rate compliance: <_ 15%, or15 10% leakage to outside or seal all accessible leaks. CF2R-MCH-25-H & MR -MCH -25-H Refrigerant Charge Verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Fldw a 300.CFM/ton required when MCH -25 is required. Exceptions: -Duct systems registered with HERS provider as previously sealed are.exempt from MCH -20 Duct Leakage �Testing requirements. �iA a asp€- 4 ,y Air or It Heating -only systems and Air Handler/Furnace changes do not require verification'of Flow MCH -23 Refrigerant Charge MECH-25. F '' -Existingducts stems constructed, insulated or sealed with asbestos,are exemfrom MCH20 Ductleaka a Testm re wremerits. Y P�.sv g e.� q e . . , r44 wrw a,.Y .,r,p: S :a _-_�' ..'_ _. ;.a tsi nxo •n,i t' E. Entirely New or Complete Replacement DucfQgtem, with or without�Equipment Changeout (Section ,150 2(b)1Dnq�and,.150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 216-A0330783A-000000000-0000 Registration Date/Time: 2016-09-07 07:15:09 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 Schema Version: 0.5555DD H RS Provider: CalCERTS Report Generated 2016-09-07 07:15:05 CERTIFICATE OF COMPLIANCE ' CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF-iR-ALT HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement - 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Robinson, Kevin /�P,!/llfiiklL�L4BJf/ Company: Signature Date: J ANTHONY PLUMBING HEATING & AIR CONDITIONING 2016-09-07 07:15:09 Address: CEA/ HERS Certification Identification (if applicable): 72216 NORTH SHORE ST #101 City/State/Zip: Phone: THOUSAND PALMS CA 92276 760-343-2121 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: _ 1. The information provided on this.Certificate.of Compliance is true and correct. 2. 1 am eligible under Division 3 of'the'Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (respo sible designer). 3. That the energy features and performance specification's, materials,' components, and manufactured devices for -the build ing,design,or system design identified on this Certificate of mpliance conform to the requirements of Title 24, Part 1 and Part6 of the California Code of Regulations i� �; a plicable compliance 4. The building design features or system design features identified on is Certifica a of Compliance areconsiste^Y wit6ithe informaUon.provided onithe� clocur to the enforcement agency fogappf6val;with this building permit application. )) R ients, worksheets, calculations, plans and specifications submitted µ t , ' . �k for S. I will ensure that a registered copy ofShis Certificate of•Compliance shall:be,made,available with'tbe building permit(s)jssued for+thebuildipg and;rnade avallable,to thetenforcemen agency all applicable inspections. I understand that a registered copy of this�Cert ficate of Compl*ante ls.,req lf�d to be.included with the documeRtation�theAbu lder p ov des to the buile�ing owner.at occ panty. < b. Responsible Designer Name: a .. Responsible Designersignature: " T LAO' Robinson, Kevin. l.QBiv Company: Date Signed: . J ANTHONY PLUMBING HEATING & AIR CONDITIONING 2016-09-07 07:15:09 Address: License: 72216 NORTH SHORE ST #101 777794 City/State/Zip: Phone: THOUSAND PALMS CA 92276 760-343-2121 Digitally signed by Ca10ERTS.. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accura of the information. Registration Number: 216-A0330783A-000000000-0000 Registration Date/Time: 2016-09-07 07:15:09 F ERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generatec: 2016-09-07 07:15:05 Schema Version: 0.555SDD