0210-258 (AR)�. LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and. effect.
•License# Lic. Class Exp. Date
783503 BI CIO H)C r 3112{
16ate -Signature of Contractor f
OWNER -BUILDER DECL/ ATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
.compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) 1, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section , B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:.
Carver.KF
MpT Policy No.
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to becop� a subject to the
workers' compensation laws of California, and agree that if I hould become
subject to the workers' compensation proyisions�o�Sectio 00 of the Labor
Code, I shall forthwith comply with those pro �iisi?n"s.
'Date: to 111 Applicant n WA
Warning: Failure to secure Workers , ompensation coverage is unlawful and
shall subject an employer to criminal, penalties and civil fines up to $100,000, in
addition to the cost of compensation damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize represen Lives of his City to enter upon
the above-mentioned property for inspe-btio purpose .
gnature (Owner/Agent) Date 0
Al
BUILDING PERMIT PERMIT#
DATE ,1 pm .w, VALUATION e�.�� LOT TRACT a g
t3'Fdc; Jl 29147-1 •.r7
JOB SITE�� APN
ADDRESS C(>CIX IffU,S! 761-500-006
OWNER
55-161 8(xTJ"YIIwFW H&?A1
Lik Q alMA -
USE OF PERMIT
JN.r'�''� SdA13DJT10N
CONTRACTOR/DESIGNER/ENGINEER
X.Af:MLA CON.M L'.t?:ON DIC
78 - 00 0 CADIZ ....
CA 922 rA.„,11RCIuA GAS, 4`2.2 5 3
1;160)564,4832 0W.4t 323'
17'w,), fA ",A:° YtXVISION W 1fid; MASTS?, DEYIR,00M (16 : QMJ
AWI T ION WITH t PA t. Icy W {+:WSION CI 1500)
`'{IS3-014 CON It RUC11iON• YV�VY tdA”
S 1y,�1lcry� ( •�, SUM
�F-SI' -SIMCOBS' OF CO�t'1Y6',ii't�'1:1'��`.�s� N
1� 'swdJ7.».'.Y.+ �'.�7. SlJ;�i:f�iiVtaQ.iR'it
PWI CHECK P`EE. 101 -00". 39.318 I40M
CONS'I'RUCTIOT? FEE :101-000-4'18-000 $63.00
S'I'`!t(7NG MOTION FEE - COMM 100-000-241-000 x,70
.1MMUT Y S DOX,140W
gym(, OF LAQU1147A
pINANCEO
RECEIPT DATE DATE F L (NSP OR
.! d . �l &3
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K. to Wrap
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wail Insulation
Condensate Lines
Party Wail Firewall
Exterior Lath
Drywall - Int. Lath
Final
Final
POOLS - SPAS
BLOCKWALL APPROVALS
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
Appliances
Final
COMMENTS:
6
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring '
Fbdures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
I�f
THE SUMMIT at PGA WEST - PLAN 313 LOT 17
La Quinta
. �1 ( s s /-�i,�,v�ea� !fir-ws �-•- ��� �i
CITY OF LA WINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE �Z BY—
Southern Hills Development, Inc.
Jeffrey A. Matzek & Associates
e
FOUNDATION ENERGY
27525 Puerta Real
Suite 103
Mission Viejo, CA 92691
949-348-2414
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
The Summit at PGA West - Plan 3B Lot 17 . 09/29/2002
Project Tide Date
La Quinta, CA
Project Address Building Permit #
Foundation Energy (949) 348-2414 Plan Check / Date
Documentation Author Telephone
Computer Performance 15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL, INFORMATION
Total Conditioned Floor Area: 4,869 ft2 Average Ceiling Height: 11.6 ft
Total. Conditioned Slab Area: 4,869 ft2
Building Type:
(check one or more)
FRI Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (North) 340 deg
Number of Dwelling Units: 1.00
Number of Stories: 1
Floor Construction Type: ® Slab Floor
ComponentFrame
Type IType
Orientation
Const.
Assembly
U -Value
Slab On Grade
n/a
0.756
Slab On Grade
n/a
0.756
R-19 Wall
Wood
0.061
R-30 Roof
Wood
0.034
FENESTRATION
❑ Raised Floor
Location/Comments
(attic, garage, typical, etc.
Exposed Slab w/R-0.0 Perimeter Insulation
Covered Slab w/R-0.0 Perimeter Insulation
Exterior Wall
Exterior Roof
Shadina Devices
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes / No
Yes / No -
Rear
(South)
97.5
1.19
0.72
Buq Screen
Q
❑
❑ Q
Rear
(South)
262.6
0.59
0.58
Bug Screen
Q
❑
❑ Q
Rear
(South)
240.0
0.62
0.52
Buq Screen
X❑
❑
❑ Q
RRi ht
(West)
77.5
1.19
0.72
Buq ScreenX❑
❑
❑ Q
Ri-gM
(West)
49.5
0.59
0.58
Buq Screen
X❑
❑
❑ 0
Right
(West)
15.0
0.72
0.73
Bug Screen
X❑
❑
❑ X❑
Front
(North)
40.0
0.55
0.65
Bug Screen
Q
❑
❑ 0
Front
(North)
57.5
1.19
0.72
Buq Screen
X❑
❑
❑ . Q
Left
(East)
68.0
1.19
0.72
Bug Screen
X❑
❑
❑ X❑
Skylight
16.0
0.94
0.60
None❑
X❑
❑ Q
Rear
(Southeast)
38.0
0.55
0.65
Bug Screen
0
❑
❑ Q
Right
(West)
8.0
0.77
.0.36
Bug Screen
Q
❑
❑ Q
Run Initiation Time: 09/29/02 20:56:08 Run Code: 1033358168
Ener Pro 3.1 B Ener Soft
User Number. 3412
Job Number. mtzpgaw17
Page: 1 of 11
Certificate of Compliance:
Residential
(Part 1 of 2) CF -1 R
The Summit at PGA West - Plan 3B Lot 17
09/29/2002
Project Title
-
pa
La Quinta. CA
-Factor
SHGQ
Project Address
Yes / No
Building Permit #
Foundation Energy
(949) 348-2414 Plan check / Date
Documentation Author
Telephone
0.73
Computer Performance
15
Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENFRAL INFORMATION
36.0
0.77
Total Conditioned Floor Area:
4,869 ft2 Average Ceiling Height: 11.6 ft
Total Conditioned Slab Area:
4,869 ft2
Left
Building Type:
57.0
0.55
(check one. or more)
Bug Screen
191 ❑
Single Family'Detached
❑ Addition
(East)
❑ Single Family Attached
❑ Existing Building
0.36
❑ Multi -Family
❑ Existing Plus Addition
❑ Q .
Front Orientation: (North)
340 deg_ Floor Construction Type:
® Slab Floor
Number of Dwelling Units:
1.00
Number of Stories:
1
❑ Raised. Floor
BUILDING SHELL INSULATION
Const.
Component Frame Assembly Location/Comments
Type Type U -Value (attic,: garage, typical, etc.)
FENESTRATION
Shading Devices
Type
Orientation
Area
Fenestration Exterior
Overhang Side Fins
SF
-Factor
SHGQ
Shading
Yes / No
Yes / No
Front
(North)
28.0
0.72
0.73
Bug ScreenX❑
❑
❑ X❑
Front
(North)
36.0
0.77
0.36
Bug Screen
191 ❑
❑ X❑
Left
(East)
57.0
0.55
0.65
Bug Screen
191 ❑
❑ X❑
Left
(East)
60.0
0.77
0.36
Bug Screen
X❑ ❑
❑ Q .
❑ ❑
❑ 1:1
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
Run Initiation Time: 09/29/02 20:56:08
Run'Code: 1033358168
Ener Pro 3.1 By Ener Soft
User Number. 3412
Job Number. mtpgawl7
Page: 2 of 11
Certificate of Compliance: Residential
(Part 2 of 2) CF -1 R
The Summit at PGA West - Plan 3B Lot 17
09/29%2002
Project Title
Water Heater Water Heater Distribution
Date
HVAC"SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
or Recovery. Standby
Distribution
System Name Type Type
Heating Equipment
Minimum Type and Duct or
Efficiency Loss (%)
Type (furnace, heat
Efficiency Location Piping
Thermostat Location /
pump, etc.)
(AFUE/HSPF)(ducts, attic, etc.) R -Value
Type Comments
Central Fumare
80% AFUE Ducts in Attic 6.0
Setback LIVING HVAC
Central Furnace
80% AFUE Ducts in Attic 6.0
Setback SLEEPING HVAC
Cooling Equipment
Minimum Duct
Type (air conditioner,
Efficiency Location Duct
Thermostat Location /
heat pump, evap. cooling)
(SEER) (attic; etc.) R -Value
Type Comments
Split Air Conditioner 12.0 SEER Ducts in Attic
Split Air Conditioner 12.0 SEER Ducts in Attic
WATER HEATING SYSTEMS
Rated 1
Tank
Energy Facts 1
External
Water Heater Water Heater Distribution
# in Input
Cap.
or Recovery. Standby
Tank Insul.
System Name Type Type
Syst. Btu/hr
(gal)
Efficiency Loss (%)
R -Value
PCR -50- Small Gas Recircrl7ime+Temp
1_ 46,000
50
0.65 n/a
n/a
06 SMITH , FPCR-50- Small Gas Recircrrime+Temp
1 46.000
50
0.65 n/a
n/a
234
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
French Door glass calculated per G-20 of Residential EC - glass plus 2 ming.
This calculation is for Base Plan 3B Lot 17.
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersign! recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an appro d HE ter.
Designer or Ownern(perM"ne & rofessions code) Documentation Author
Name: Name:
Title/Firm: SoutKehn Hills Development, Inc. Title/Firm
Address: 55 61 Southem Hills Address:
Benito Ramirez
Foundation Enerciv
27525 Puerta Real #103
Mission Viejo, CA 92691
Telephone: 760-771-1761 Telephone: (949) W-2414
Lic. #:
6 0a
(signature) (date) (signature) V I (date)
Enforce, a Agency
Name:
Title/Firm:
Address:
Telephone:
(signature/stamp) (date)
Run Initiation Time: 09/29/02 20:56:08 Run Code: 1033358168
EnergyPro 3.1 By EnergySoft User Number. 3412 Job Number. mtzpgaw17 Page:3 of 11
Certificate of Compliance: Residential (Addendum) CF -1'R
The Summit at PGA West - Plan 3B Lot 17 09/29/2002
Project Tide Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. Plan I Field
The HVAC System "LIVING HVAC" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "LIVING HVAC" has R-6.0 Heating' Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "LIVING HVAC" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
HIGH MASS Design(see C -2R) - Verity Thermal Mass: 1519 so Exposed Slab Floor, 3.50" thick at Living Areas
HIGH MASS Design(see C-211) - Verify Thermal Mass: 680 sgft Covered Slab Floor, 3.50" thick at Living Areas
The HVAC System "SLEEPING HVAC" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
The HVAC System "SLEEPING HVAC" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "SLEEPING HVAC" has R76.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1970 sqft Exposed Slab Floor, 3.50" thick.at Sleeping Areas
HIGH MASS Design(see C -2R) - Verify Thermal Mass:. 700 sgft Covered Slab Floor, 3.50" thick at Sleeping Areas
4 -
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -611. Plan I Field
The HVAC System "LIVING HVAC" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "LIVING HVAC" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "SLEEPING HVAC" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must
provide verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "SLEEPING HVAC" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
Run Initiation Time: 09/29/02 20:56:08 'Run Code: 1033358168
EnergyPro 3.1 By EnergySoft User Number.' 3412 Job Number: mt Naw17 . Page:4 of 11
Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R .
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable.
DESIGNER
ENFORCEMENT
Building,,Envelope Measures
'§150(a): -Minimum R-19 ceiling insulation.
§150(b)- Loose fill insulation manufacturer's labeled R -Value.
❑ i
• § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
not apply to exterior mass walls).
a*§150(d): ' Minimum R-13 raised floor insulation in framed floors or equivalent
❑§ 150(1): � Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 permfinch.
a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfifbation Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§150(f):i Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
❑X
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
a§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMAC NA or ACCA.
§150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑X §1500): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined intemaVextemal insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank
EnergyPro 3.1 By EnergySoft User Number. 3412 Job Number. mIzpgaw17 Page:5 of 11
Mandatory Measures, Checklist: Residential (Page 2 of 2) MF -1 R .
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk
(') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications, for the mandatory measures whether they are
shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
F1150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 63; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of dud systems and their components shall not be
sealed with cloth back rubber adhesive dud tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, dud board or flexible dud shall not be used for conveying conditioned air. Building
cavities and support platforms may contain duds. Duds installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the duds.
3. Joints and seams of dud systems and their components shall not be sealed with doth back rubber adhesive
dud tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eittwautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and, provides shielding
from solar radiation that can cause degradation of the material.
❑ § 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, onoff switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36' of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Gas fired central fumaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
❑ §118 (f): Cool Roof material meet specified criteria
Lighting Measures
❑ § 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumenstwatt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with.an efficacy of
40 Iumenshvatt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling .fixtures are IC (insulation cover) approved.
3.1 By EnergySoft User Number. 3412 Job Number: mtzpgawl7 Page:6 of 11
Computer Method Summary
(Part 1 of 3) C -2R
TheSummit at PCIA
Project Title
West - PlanB Lot
17
09/29/2002
Date
_I a_Qi inter, CA
Project Address
Building Permit #
Foundation Energy
(949) 348-2414
Documentation Author
Telephone
Plan Check/Date
C'omouter Performance
Compliance Method (Package
or Computer)
15
Climate Zone
Field Check/Date
Source Energy Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
3.27
3.23
0.04
Space Cooling
-34.17
33.89
0.28
Domestic Hot Water
5.85
5.68
0.18
Totals
43.29
42.80
0.50
GENERAL INFORMATION XD Slab Floor
Conditioned Floor Area: 4,869 Floor Construction Type: r-]RaisedFloor
Building Type: Single Fam Detached
Building Front Orientation: (North) 340 deg Total Fenestration Area: 23.6%
Number of Dwelling Units: 1.00 Total Conditioned Volume: 56,543
Number of Stories: 1 Slab Floor Area: 4,869
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
I MNG HVAC 2 199199 27 707707 n 45 1 raring I ivinBStat _2 n/a
SLEEPING HVAC 2.67 298 0-m Sleepi is SleapmnqStat _2 n!a
OPAQUE SURFACES Act.
Type Area U -Fac. Azm. Tilt
Wall 210 0.061 goo 90
wall— 20 0.061 ?-qn 90
Wall 256 0.061 20 go
Wall 352 0.061 110 _90
Rnnf 7199 0.034 20 �.
Roof 2 654 0.034 7n —22
Wall 37 0.061 1555 90
Wag 111 0.061 700 90
Wall 1,072 0.061 290 90
wap 292 0.061 20 _90
Wall 767 0.061 110 90
Solar
Gains
Location / Comments
Living Zone
Living 7n
I iving 7nne
Living Zone
Living Zone
Sleeping Zone
Sleeping Zone
Sleepipg Zone
Sleeping 7nne
Sleep Znne
Sleepip9 Zone
. EnergyPro 3.1 By EnergySoft User Number: 3412 Job Number: mtzpgaw17 Pam:7 of 11 1
Comgute.r Method Summary (Part 2 of 3) C -2R
The Summit at PGA West - Plan 3B Lot 17 09/29/2002
Project Title Date
FENESTRATION SURFACES
#
Type
Window
Area
U-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
Location
Comments
j_
Window
Rear
_(South)
40-5
1-190
0-72
900
90 Single Comer Rid,loint
Living one '
2
Window
Rear
(South)
43.5
0.590
0.58
200
90 Double Bronze
Living Zone
3
Window
Rear
(South)
80.0
0.620
0.52
200
90 Double Bronze
Living Zone
.4'
Window
Rear
(South)
24.5
1.190
0.72
200
90 Single Comer But -Joint
Living Zone
5
Window
Rear
(South)
26.5
0.590
0.58
200
90 Double Bronze
Living Zone
6
.Window
Rear '
(South)
24.5
0.590
0.58
200
90 Double Bronze
Living Zone
L
Window
Rear
(South)
32.5
0.590
0.58
200
90 Double Bronze
Living Zone
8
Window
Rear
(South)
32.5
1.190
0.72
200
90 Single Comer Bat oint
Living Zone
6
Window
Rear
(South)
16.0,
0.590
0.58
200
90 Double Bronze
Living Zone
1Q
Window
Rear
(South)
80.0
0.620
0.52
200
90. Double Bronze -
ung Zone
"
Window
Rear
(South)
9.5 ,
0.590
0.58
200
90 Double Bronze
Living Zone
12
Window
Rear
(South)
43.5
0.590
0.58
200
90 Double Bronze
Living Zone
1U
Window
Right
(West)
-34.0
1-190
'0,72
290
90 Single Comer B�n�loint
1Living Zone
14
Window
Right
(West)
25.5
0.590
0.58
290
90 Double Bronze
Living Zone
15
Window
Right
(West)
43.5
1.190
0.72
290
90 Sinqle Comer ButJoint
Living Zone
16
Window
Right
(West
15.0
0.720
0.73
290
90 Double Glass Block
Living Zone
17
Window
Front
(North)
40.0
0.550
0.65
20
90 Double Bronze
Living Zone "
18
Window
Front
(North)
57.5
1.190
0.72
20
90 Sinqle Comer But -Joint
Living Zone
9
Window
Left
(Easy
43.5 ''
1.190
0.72
110
90 $b9 Comer l3mU-om
Living Zone
20
Window
Left
(East)
24.5
1.190
0.72.
110
90 Single Comer But -Joint
Living Zone
21
Skylight
Front
(North)
16.0
0.940
0.60
20
22 Double MI Tinted Default
Sleeping Zone
22
Window
Rear
Southeast)
38.0
0.550
0.65
155
90 Double Bronze
Sleeping Zone
23
Window
Rear
(South
80.0
0.620
0.52
200
90 Double Bronze
Sleeping Zone
24
Window
Rear
(South)
66.6
0.590
0.58
200
90 Double Bronze
Sleeping Zone
25
Window
Right
(West)
12.0
0.590
0.58
290
90 Double Bronze
Sleeping Zone
26
Window
Right
(West)
12.0
0.590
0.58
290
90 Double Bronze
Sleeping Zone
27
Window
Right
(West)
8.0
0.770
0.36
290
90 Double Bronze
Steeping Zone
28
Window
Front
(North)
18.0
0.720
0.73
20
90 Double Glass Block
Sleeping Zone
29
Window
Front
(North)
18.0
0.770
0.36
20
90 Double Bronze
Sleeping Zone
INTERIOR AND EXTERIOR SHADING
#
Window
Overhand_
Left Fin Right Fin
Exterior Shade Type
SHGC
Hgt.
Wd.
Len.
H t.
LExt.
Ext. Dist. Len. H t. Dist. Len. H t.
1
Bug Screen
0.76.
9.0
4.5
11.0
0.5
11.0
11.0
2
Bug Screen
0.76
9.0
4.9
11.0
0.5
11.0
11.0
3
Bug Screen
0.76
10.0
8.0
11.0
0.5
11.0
11.0
4
Bug Screen
0.76
7.5 '
3.3
3.0
0.5
3.0
3.0
5
Bu q Screen
0.76
7.4
3.6
3.0
0.5
3.0
3.0
6
Bug Screen
0.76
7.4
3-3
3.0
0.5
3.0
3.0
7
Bug Screen
0.76
7.4
4.4
8.0
4.0
8.0
8.0
8
Bug Screen
0.76
7.4
4.4
8.0
4.0
8.0
8.0
9
Bug Screen
0.76
2.0
8.0
14.5
1.0
14.5
14.5
10
Bu q Screen
0.76 •
10.0
8.0
14.5
4.0
14.5
14.5
11
Bug Screen
0.76
2.0
4.9
14.5
1.0
14.5
14.5
12
Bug Screen
0.76
9.0
4.9
14.5
4.0
14.5
14.5
13
Bug Screen
0.76
7.3
4.6
11.0
4.0
11.0
11.0
14
Bug Screen
0.76
9.0
2.9
13.0
3.5
13.0
13.0
15
Bug Screen
0.76
9.0
4.9
13.0
3.5
13.0
13.0
16
Bug Screen
0.76
5.0
3.0
2.5
0.5
2.5
2.5
17
Bug Screen
0.76
8.0
5.0
11.0
1.0
11.0
11.0
18
Bug Screen
0.76
9.0
6.4
1.5
3.5
1.5
1.5
19
Bug Screen
0.76
9.0
4.9
2.5
0.5
2.5
2.5
20
Bug Screen
0.76
7.4
3.3
5.0
0.5
5.0
5.0
21
None
1.00
22
Bug Screen
0.76
6.4
4.8
1.5
0.5
1.5
1.5
23
Bug Screen
0.76
10.0
8.0
6.0
0.5
6.0
6.0
24
Bug Screen
0.76
9.1
7.3
6.0
. 0.5
6.0
6.0
25
Bug Screen
0.76
4.0
3.0
1.5
3.5
1.5
1.5
26
Bug Screen
0.76
4.0
3.0
1.5
3.5
1.5
1.5
27
Bug Screen
0.76
4.0
2.0
1.5
1.5
1.5
1.5
28
Bug Screen
0.76
4.5
• 4.0
-2.5.-0.5
2.5
2.5
29 .
Bug Screen
0.76
6.0
3.0
3.5
0.5
3.5
3.5
EnergyPro 3.1 RV Fnprgygoft User Number: 3412 Job Number: mtzpgawl7 Page:B of 11
. Computer Method Summary
(Part 2 of 2L C -2R
The Summit at PGA West - Plan 3B Lot 17
09/29/2002
Project Title
Date
FENESTRATION SURFACES
U-
Act..
Glazing Type
Location/
# Type
Area
Factor
SHGC
Azm. Tilt
Comments
-K Window Front (North)
18.0
0.770
0.36
20
90 Double Bronze
Sleeping Zone
31 Window Front (North)
10.0
0.720
0.73
20
90 Double Glass Block
Sleeping Zone
32 Window Left (East)
38.0
0.550
0.65
110
90 Double Bronze
Sleeping Zone
33 Window Left (East)
19.0
0.550
0.65
110
90 Double Bronze
Sleeping Zone
34 Window Left (East)
30.0
0.770
0.36
110
90 Double Bronze
Sleeping Zone
35 Window Left (Eag)
30.0
0.770
0.36
110
90 Double Bronze
Sleeping Zone
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin Right Fin
# Exterior Shade Type
SHGC
Hgt.
Wd.
Len. H t.
LExt. RExt. Dist.
Len. H t. Dist. Len. H t.
30 Bug Screen
0.76
6.0
3.0
3.5 0.5
3.5 3.5
31 Bug Screen
0.76
5.0
2.0
1.5 4.0
1.5 1.5
32 Bug Screen
0.76
6.4
4.7
1.5 0.5
1.5 1.5
33 Bug Screen
0.76
6.4
2.4
1.5 3.5
1.5 1.5
34 Bug Screen
0.76
5.0
6.0
1.5 1.5
1.5 1.5
35 Bug Screen
0.76
5.0
6.0
1.5 3.5
1.5 1.5
Energypro 3.1 Rv FnamvSoft User Number: 3412 Job Number: mtzpgawl7 PaQe:9 of 11 1
Computer Method Summary
F2
(Part 3 of 3) C -2R
The Summit at PGA West - Plan 3B Lot 17
Factor R -Val. Depth Location / Comments
09/29/2002
Project Title
Slab Perimeter 101
0_76
Date
THERMAL MASS FOR HIGH MASS DESIGN
Slab Perimeter 40
Area Thick. Heat
0 0 0 Living
Inside
Location
Type (sf) (in.) Cap.
Cond. Form 3 Reference
R -Val.
Comments
Concrete, Heavyweight 1,519 3.50 _—M
0.98 n/a
Slab Perimeter 50
Living Zone / Slab on Grade
Concrete, Heavyweight 680 3_50 28
0.98 n/a
_0
2
Living Zone / Slab on Grade
Concrete Hea eight 1,970 3.50 28
0.98 n/a
0
Sleeping Zone / Slab on Grade
'Concrete. Heavyweight 700 3.50 28
0.98 rda
2
Sleeping Zone / Slab on Grade
PERIMETER LOSSES
For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
French Door glass calculated per G-20 of Residential ECM - glass plus 2" framing.
This calculation is for Base Plan 3B Lot 17.
F2
Insulation
Type Length
Factor R -Val. Depth Location / Comments
Slab Perimeter 101
0_76
0.0 0 Living
Zone
Slab Perimeter 40
0.76
0 0 0 Living
Zone
Slab Perimeter 205
0_76
0.0 0 Sleeping Zone.
Slab Perimeter 50
0.76
0.0 0 Sleeping Zone
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Type (furnace, heat
Efficiency
and Location
Duct Thermostat
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic,
etc.)
R -Value Type
Comments
Central Furnace
80%AFUE
Ducts in Attic
6.0 Setback
LIVING HVAC
Central Furnace
80%AFUE
Ducts in Attic
6.0 Setback
SLEEPING HVAC
Hydronic Piping
Pipe
Pipe
Insul.
System Name Length Diameter Thick.
Cooling Equipment
Minimum
Duct
Type (air conditioner,
Efficiency
Location
Duct Thermostat
Location/
heat pump, evap. cooling)
(SEER)
(attic, etc,)
R -Value Type
Comments
Split Air conditioner
.12 .0 SEE
Ducts in Attic
6.0 Setback
LIVING HVAC
Split Air Conditioner
12.0 SEER
Ducts in Attic
6.0 Setback
SLEEPING HVAC
WATER HEATING SYSTEMS
Rated' Tank
Energy Facts 1
Tank Insul.
Water Heater
Water Heater Distribution
# in Input Cap.
or Recovery Standby
R -Value
System Name
Type
Type
Syst. (Btu/hr) (gal)
Efficiency Loss M)
Ext
A O SMITH FPCR-50-234
Small Gas
Recirctfime+Temp
1 46,000 50
0.65 n/a
n/a
A O SMITH FPCR-50-234
Small as
RecircTme+Temp
1 46.000 50
0.65 n/a
n/a
For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
French Door glass calculated per G-20 of Residential ECM - glass plus 2" framing.
This calculation is for Base Plan 3B Lot 17.
Computer Method Summary %(Addendum) C -2R
The Summit at PGA West Plan 3B Lot 17 09/29/2002
Project Title
Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist These items require special
written. justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted.
The HVAC System "LIVING HVAC" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "LIVING HVAC" has R-6.0 Heating -Duct Insulation. Insulation levels above R-42 must be verified.
The HVAC System "LIVING HVAC" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1519 sgft Exposed Slab Floor, 3.50" thick at Living Areas
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 680 sgft Covered Slab Floor, 3.50" thick at Living Areas
The HVAC System "SLEEPING HVAC" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
The HVAC System "SLEEPING HVAC" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified.
The HVAC System "SLEEPING HVAC" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1970 sgft Exposed Slab Floor, 3.50" thick at Sleeping Areas
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 700 sgft Covered Slab Floor, 3.50" thick at Sleeping Areas
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. IPlan I Field
The HVAC System "LIVING HVAC" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verifrfication of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "LIVING HVAC" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "SLEEPING HVAC" includes.Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must
provide verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "SLEEPING HVAC" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
EnergyPro 3.1 By EnergySoft User Number. 3412 Job Number.
mtzpgaw17 1PaQe:11 of 11