Loading...
0210-258 (AR)�. LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and. effect. •License# Lic. Class Exp. Date 783503 BI CIO H)C r 3112{ 16ate -Signature of Contractor f OWNER -BUILDER DECL/ ATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole .compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section , B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are:. Carver.KF MpT Policy No. (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to becop� a subject to the workers' compensation laws of California, and agree that if I hould become subject to the workers' compensation proyisions�o�Sectio 00 of the Labor Code, I shall forthwith comply with those pro �iisi?n"s. 'Date: to 111 Applicant n WA Warning: Failure to secure Workers , ompensation coverage is unlawful and shall subject an employer to criminal, penalties and civil fines up to $100,000, in addition to the cost of compensation damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize represen Lives of his City to enter upon the above-mentioned property for inspe-btio purpose . gnature (Owner/Agent) Date 0 Al BUILDING PERMIT PERMIT# DATE ,1 pm .w, VALUATION e�.�� LOT TRACT a g t3'Fdc; Jl 29147-1 •.r7 JOB SITE�� APN ADDRESS C(>CIX IffU,S! 761-500-006 OWNER 55-161 8(xTJ"YIIwFW H&?A1 Lik Q alMA - USE OF PERMIT JN.r'�''� SdA13DJT10N CONTRACTOR/DESIGNER/ENGINEER X.Af:MLA CON.M L'.t?:ON DIC 78 - 00 0 CADIZ .... CA 922 rA.„,11RCIuA GAS, 4`2.2 5 3 1;160)564,4832 0W.4t 323' 17'w,), fA ",A:° YtXVISION W 1fid; MASTS?, DEYIR,00M (16 : QMJ AWI T ION WITH t PA t. Icy W {+:WSION CI 1500) `'{IS3-014 CON It RUC11iON• YV�VY tdA” S 1y,�1lcry� ( •�, SUM �F-SI' -SIMCOBS' OF CO�t'1Y6',ii't�'1:1'��`.�s� N 1� 'swdJ7.».'.Y.+ �'.�7. SlJ;�i:f�iiVtaQ.iR'it PWI CHECK P`EE. 101 -00". 39.318 I40M CONS'I'RUCTIOT? FEE :101-000-4'18-000 $63.00 S'I'`!t(7NG MOTION FEE - COMM 100-000-241-000 x,70 .1MMUT Y S DOX,140W gym(, OF LAQU1147A pINANCEO RECEIPT DATE DATE F L (NSP OR .! d . �l &3 INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wail Insulation Condensate Lines Party Wail Firewall Exterior Lath Drywall - Int. Lath Final Final POOLS - SPAS BLOCKWALL APPROVALS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final COMMENTS: 6 Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring ' Fbdures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) I�f THE SUMMIT at PGA WEST - PLAN 313 LOT 17 La Quinta . �1 ( s s /-�i,�,v�ea� !fir-ws �-•- ��� �i CITY OF LA WINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE �Z BY— Southern Hills Development, Inc. Jeffrey A. Matzek & Associates e FOUNDATION ENERGY 27525 Puerta Real Suite 103 Mission Viejo, CA 92691 949-348-2414 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R The Summit at PGA West - Plan 3B Lot 17 . 09/29/2002 Project Tide Date La Quinta, CA Project Address Building Permit # Foundation Energy (949) 348-2414 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL, INFORMATION Total Conditioned Floor Area: 4,869 ft2 Average Ceiling Height: 11.6 ft Total. Conditioned Slab Area: 4,869 ft2 Building Type: (check one or more) FRI Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 340 deg Number of Dwelling Units: 1.00 Number of Stories: 1 Floor Construction Type: ® Slab Floor ComponentFrame Type IType Orientation Const. Assembly U -Value Slab On Grade n/a 0.756 Slab On Grade n/a 0.756 R-19 Wall Wood 0.061 R-30 Roof Wood 0.034 FENESTRATION ❑ Raised Floor Location/Comments (attic, garage, typical, etc. Exposed Slab w/R-0.0 Perimeter Insulation Covered Slab w/R-0.0 Perimeter Insulation Exterior Wall Exterior Roof Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No - Rear (South) 97.5 1.19 0.72 Buq Screen Q ❑ ❑ Q Rear (South) 262.6 0.59 0.58 Bug Screen Q ❑ ❑ Q Rear (South) 240.0 0.62 0.52 Buq Screen X❑ ❑ ❑ Q RRi ht (West) 77.5 1.19 0.72 Buq ScreenX❑ ❑ ❑ Q Ri-gM (West) 49.5 0.59 0.58 Buq Screen X❑ ❑ ❑ 0 Right (West) 15.0 0.72 0.73 Bug Screen X❑ ❑ ❑ X❑ Front (North) 40.0 0.55 0.65 Bug Screen Q ❑ ❑ 0 Front (North) 57.5 1.19 0.72 Buq Screen X❑ ❑ ❑ . Q Left (East) 68.0 1.19 0.72 Bug Screen X❑ ❑ ❑ X❑ Skylight 16.0 0.94 0.60 None❑ X❑ ❑ Q Rear (Southeast) 38.0 0.55 0.65 Bug Screen 0 ❑ ❑ Q Right (West) 8.0 0.77 .0.36 Bug Screen Q ❑ ❑ Q Run Initiation Time: 09/29/02 20:56:08 Run Code: 1033358168 Ener Pro 3.1 B Ener Soft User Number. 3412 Job Number. mtzpgaw17 Page: 1 of 11 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R The Summit at PGA West - Plan 3B Lot 17 09/29/2002 Project Title - pa La Quinta. CA -Factor SHGQ Project Address Yes / No Building Permit # Foundation Energy (949) 348-2414 Plan check / Date Documentation Author Telephone 0.73 Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENFRAL INFORMATION 36.0 0.77 Total Conditioned Floor Area: 4,869 ft2 Average Ceiling Height: 11.6 ft Total Conditioned Slab Area: 4,869 ft2 Left Building Type: 57.0 0.55 (check one. or more) Bug Screen 191 ❑ Single Family'Detached ❑ Addition (East) ❑ Single Family Attached ❑ Existing Building 0.36 ❑ Multi -Family ❑ Existing Plus Addition ❑ Q . Front Orientation: (North) 340 deg_ Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised. Floor BUILDING SHELL INSULATION Const. Component Frame Assembly Location/Comments Type Type U -Value (attic,: garage, typical, etc.) FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF -Factor SHGQ Shading Yes / No Yes / No Front (North) 28.0 0.72 0.73 Bug ScreenX❑ ❑ ❑ X❑ Front (North) 36.0 0.77 0.36 Bug Screen 191 ❑ ❑ X❑ Left (East) 57.0 0.55 0.65 Bug Screen 191 ❑ ❑ X❑ Left (East) 60.0 0.77 0.36 Bug Screen X❑ ❑ ❑ Q . ❑ ❑ ❑ 1:1 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 09/29/02 20:56:08 Run'Code: 1033358168 Ener Pro 3.1 By Ener Soft User Number. 3412 Job Number. mtpgawl7 Page: 2 of 11 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R The Summit at PGA West - Plan 3B Lot 17 09/29%2002 Project Title Water Heater Water Heater Distribution Date HVAC"SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. or Recovery. Standby Distribution System Name Type Type Heating Equipment Minimum Type and Duct or Efficiency Loss (%) Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Fumare 80% AFUE Ducts in Attic 6.0 Setback LIVING HVAC Central Furnace 80% AFUE Ducts in Attic 6.0 Setback SLEEPING HVAC Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic; etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic Split Air Conditioner 12.0 SEER Ducts in Attic WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery. Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value PCR -50- Small Gas Recircrl7ime+Temp 1_ 46,000 50 0.65 n/a n/a 06 SMITH , FPCR-50- Small Gas Recircrrime+Temp 1 46.000 50 0.65 n/a n/a 234 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS French Door glass calculated per G-20 of Residential EC - glass plus 2 ming. This calculation is for Base Plan 3B Lot 17. COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersign! recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an appro d HE ter. Designer or Ownern(perM"ne & rofessions code) Documentation Author Name: Name: Title/Firm: SoutKehn Hills Development, Inc. Title/Firm Address: 55 61 Southem Hills Address: Benito Ramirez Foundation Enerciv 27525 Puerta Real #103 Mission Viejo, CA 92691 Telephone: 760-771-1761 Telephone: (949) W-2414 Lic. #: 6 0a (signature) (date) (signature) V I (date) Enforce, a Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) Run Initiation Time: 09/29/02 20:56:08 Run Code: 1033358168 EnergyPro 3.1 By EnergySoft User Number. 3412 Job Number. mtzpgaw17 Page:3 of 11 Certificate of Compliance: Residential (Addendum) CF -1'R The Summit at PGA West - Plan 3B Lot 17 09/29/2002 Project Tide Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan I Field The HVAC System "LIVING HVAC" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "LIVING HVAC" has R-6.0 Heating' Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "LIVING HVAC" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. HIGH MASS Design(see C -2R) - Verity Thermal Mass: 1519 so Exposed Slab Floor, 3.50" thick at Living Areas HIGH MASS Design(see C-211) - Verify Thermal Mass: 680 sgft Covered Slab Floor, 3.50" thick at Living Areas The HVAC System "SLEEPING HVAC" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "SLEEPING HVAC" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "SLEEPING HVAC" has R76.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1970 sqft Exposed Slab Floor, 3.50" thick.at Sleeping Areas HIGH MASS Design(see C -2R) - Verify Thermal Mass:. 700 sgft Covered Slab Floor, 3.50" thick at Sleeping Areas 4 - HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -611. Plan I Field The HVAC System "LIVING HVAC" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "LIVING HVAC" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "SLEEPING HVAC" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "SLEEPING HVAC" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 09/29/02 20:56:08 'Run Code: 1033358168 EnergyPro 3.1 By EnergySoft User Number.' 3412 Job Number: mt Naw17 . Page:4 of 11 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R . NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Building,,Envelope Measures '§150(a): -Minimum R-19 ceiling insulation. §150(b)- Loose fill insulation manufacturer's labeled R -Value. ❑ i • § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). a*§150(d): ' Minimum R-13 raised floor insulation in framed floors or equivalent ❑§ 150(1): � Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 permfinch. a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfifbation Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f):i Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑X §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures a§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMAC NA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑X §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemaVextemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank EnergyPro 3.1 By EnergySoft User Number. 3412 Job Number. mIzpgaw17 Page:5 of 11 Mandatory Measures, Checklist: Residential (Page 2 of 2) MF -1 R . NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications, for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) F1150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 63; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of dud systems and their components shall not be sealed with cloth back rubber adhesive dud tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, dud board or flexible dud shall not be used for conveying conditioned air. Building cavities and support platforms may contain duds. Duds installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the duds. 3. Joints and seams of dud systems and their components shall not be sealed with doth back rubber adhesive dud tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eittwautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and, provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, onoff switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36' of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central fumaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ❑ § 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumenstwatt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with.an efficacy of 40 Iumenshvatt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling .fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 3412 Job Number: mtzpgawl7 Page:6 of 11 Computer Method Summary (Part 1 of 3) C -2R TheSummit at PCIA Project Title West - PlanB Lot 17 09/29/2002 Date _I a_Qi inter, CA Project Address Building Permit # Foundation Energy (949) 348-2414 Documentation Author Telephone Plan Check/Date C'omouter Performance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.27 3.23 0.04 Space Cooling -34.17 33.89 0.28 Domestic Hot Water 5.85 5.68 0.18 Totals 43.29 42.80 0.50 GENERAL INFORMATION XD Slab Floor Conditioned Floor Area: 4,869 Floor Construction Type: r-]RaisedFloor Building Type: Single Fam Detached Building Front Orientation: (North) 340 deg Total Fenestration Area: 23.6% Number of Dwelling Units: 1.00 Total Conditioned Volume: 56,543 Number of Stories: 1 Slab Floor Area: 4,869 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area I MNG HVAC 2 199199 27 707707 n 45 1 raring I ivinBStat _2 n/a SLEEPING HVAC 2.67 298 0-m Sleepi is SleapmnqStat _2 n!a OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Wall 210 0.061 goo 90 wall— 20 0.061 ?-qn 90 Wall 256 0.061 20 go Wall 352 0.061 110 _90 Rnnf 7199 0.034 20 �. Roof 2 654 0.034 7n —22 Wall 37 0.061 1555 90 Wag 111 0.061 700 90 Wall 1,072 0.061 290 90 wap 292 0.061 20 _90 Wall 767 0.061 110 90 Solar Gains Location / Comments Living Zone Living 7n I iving 7nne Living Zone Living Zone Sleeping Zone Sleeping Zone Sleepipg Zone Sleeping 7nne Sleep Znne Sleepip9 Zone . EnergyPro 3.1 By EnergySoft User Number: 3412 Job Number: mtzpgaw17 Pam:7 of 11 1 Comgute.r Method Summary (Part 2 of 3) C -2R The Summit at PGA West - Plan 3B Lot 17 09/29/2002 Project Title Date FENESTRATION SURFACES # Type Window Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location Comments j_ Window Rear _(South) 40-5 1-190 0-72 900 90 Single Comer Rid,loint Living one ' 2 Window Rear (South) 43.5 0.590 0.58 200 90 Double Bronze Living Zone 3 Window Rear (South) 80.0 0.620 0.52 200 90 Double Bronze Living Zone .4' Window Rear (South) 24.5 1.190 0.72 200 90 Single Comer But -Joint Living Zone 5 Window Rear (South) 26.5 0.590 0.58 200 90 Double Bronze Living Zone 6 .Window Rear ' (South) 24.5 0.590 0.58 200 90 Double Bronze Living Zone L Window Rear (South) 32.5 0.590 0.58 200 90 Double Bronze Living Zone 8 Window Rear (South) 32.5 1.190 0.72 200 90 Single Comer Bat oint Living Zone 6 Window Rear (South) 16.0, 0.590 0.58 200 90 Double Bronze Living Zone 1Q Window Rear (South) 80.0 0.620 0.52 200 90. Double Bronze - ung Zone " Window Rear (South) 9.5 , 0.590 0.58 200 90 Double Bronze Living Zone 12 Window Rear (South) 43.5 0.590 0.58 200 90 Double Bronze Living Zone 1U Window Right (West) -34.0 1-190 '0,72 290 90 Single Comer B�n�loint 1Living Zone 14 Window Right (West) 25.5 0.590 0.58 290 90 Double Bronze Living Zone 15 Window Right (West) 43.5 1.190 0.72 290 90 Sinqle Comer ButJoint Living Zone 16 Window Right (West 15.0 0.720 0.73 290 90 Double Glass Block Living Zone 17 Window Front (North) 40.0 0.550 0.65 20 90 Double Bronze Living Zone " 18 Window Front (North) 57.5 1.190 0.72 20 90 Sinqle Comer But -Joint Living Zone 9 Window Left (Easy 43.5 '' 1.190 0.72 110 90 $b9 Comer l3mU-om Living Zone 20 Window Left (East) 24.5 1.190 0.72. 110 90 Single Comer But -Joint Living Zone 21 Skylight Front (North) 16.0 0.940 0.60 20 22 Double MI Tinted Default Sleeping Zone 22 Window Rear Southeast) 38.0 0.550 0.65 155 90 Double Bronze Sleeping Zone 23 Window Rear (South 80.0 0.620 0.52 200 90 Double Bronze Sleeping Zone 24 Window Rear (South) 66.6 0.590 0.58 200 90 Double Bronze Sleeping Zone 25 Window Right (West) 12.0 0.590 0.58 290 90 Double Bronze Sleeping Zone 26 Window Right (West) 12.0 0.590 0.58 290 90 Double Bronze Sleeping Zone 27 Window Right (West) 8.0 0.770 0.36 290 90 Double Bronze Steeping Zone 28 Window Front (North) 18.0 0.720 0.73 20 90 Double Glass Block Sleeping Zone 29 Window Front (North) 18.0 0.770 0.36 20 90 Double Bronze Sleeping Zone INTERIOR AND EXTERIOR SHADING # Window Overhand_ Left Fin Right Fin Exterior Shade Type SHGC Hgt. Wd. Len. H t. LExt. Ext. Dist. Len. H t. Dist. Len. H t. 1 Bug Screen 0.76. 9.0 4.5 11.0 0.5 11.0 11.0 2 Bug Screen 0.76 9.0 4.9 11.0 0.5 11.0 11.0 3 Bug Screen 0.76 10.0 8.0 11.0 0.5 11.0 11.0 4 Bug Screen 0.76 7.5 ' 3.3 3.0 0.5 3.0 3.0 5 Bu q Screen 0.76 7.4 3.6 3.0 0.5 3.0 3.0 6 Bug Screen 0.76 7.4 3-3 3.0 0.5 3.0 3.0 7 Bug Screen 0.76 7.4 4.4 8.0 4.0 8.0 8.0 8 Bug Screen 0.76 7.4 4.4 8.0 4.0 8.0 8.0 9 Bug Screen 0.76 2.0 8.0 14.5 1.0 14.5 14.5 10 Bu q Screen 0.76 • 10.0 8.0 14.5 4.0 14.5 14.5 11 Bug Screen 0.76 2.0 4.9 14.5 1.0 14.5 14.5 12 Bug Screen 0.76 9.0 4.9 14.5 4.0 14.5 14.5 13 Bug Screen 0.76 7.3 4.6 11.0 4.0 11.0 11.0 14 Bug Screen 0.76 9.0 2.9 13.0 3.5 13.0 13.0 15 Bug Screen 0.76 9.0 4.9 13.0 3.5 13.0 13.0 16 Bug Screen 0.76 5.0 3.0 2.5 0.5 2.5 2.5 17 Bug Screen 0.76 8.0 5.0 11.0 1.0 11.0 11.0 18 Bug Screen 0.76 9.0 6.4 1.5 3.5 1.5 1.5 19 Bug Screen 0.76 9.0 4.9 2.5 0.5 2.5 2.5 20 Bug Screen 0.76 7.4 3.3 5.0 0.5 5.0 5.0 21 None 1.00 22 Bug Screen 0.76 6.4 4.8 1.5 0.5 1.5 1.5 23 Bug Screen 0.76 10.0 8.0 6.0 0.5 6.0 6.0 24 Bug Screen 0.76 9.1 7.3 6.0 . 0.5 6.0 6.0 25 Bug Screen 0.76 4.0 3.0 1.5 3.5 1.5 1.5 26 Bug Screen 0.76 4.0 3.0 1.5 3.5 1.5 1.5 27 Bug Screen 0.76 4.0 2.0 1.5 1.5 1.5 1.5 28 Bug Screen 0.76 4.5 • 4.0 -2.5.-0.5 2.5 2.5 29 . Bug Screen 0.76 6.0 3.0 3.5 0.5 3.5 3.5 EnergyPro 3.1 RV Fnprgygoft User Number: 3412 Job Number: mtzpgawl7 Page:B of 11 . Computer Method Summary (Part 2 of 2L C -2R The Summit at PGA West - Plan 3B Lot 17 09/29/2002 Project Title Date FENESTRATION SURFACES U- Act.. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments -K Window Front (North) 18.0 0.770 0.36 20 90 Double Bronze Sleeping Zone 31 Window Front (North) 10.0 0.720 0.73 20 90 Double Glass Block Sleeping Zone 32 Window Left (East) 38.0 0.550 0.65 110 90 Double Bronze Sleeping Zone 33 Window Left (East) 19.0 0.550 0.65 110 90 Double Bronze Sleeping Zone 34 Window Left (East) 30.0 0.770 0.36 110 90 Double Bronze Sleeping Zone 35 Window Left (Eag) 30.0 0.770 0.36 110 90 Double Bronze Sleeping Zone INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. H t. LExt. RExt. Dist. Len. H t. Dist. Len. H t. 30 Bug Screen 0.76 6.0 3.0 3.5 0.5 3.5 3.5 31 Bug Screen 0.76 5.0 2.0 1.5 4.0 1.5 1.5 32 Bug Screen 0.76 6.4 4.7 1.5 0.5 1.5 1.5 33 Bug Screen 0.76 6.4 2.4 1.5 3.5 1.5 1.5 34 Bug Screen 0.76 5.0 6.0 1.5 1.5 1.5 1.5 35 Bug Screen 0.76 5.0 6.0 1.5 3.5 1.5 1.5 Energypro 3.1 Rv FnamvSoft User Number: 3412 Job Number: mtzpgawl7 PaQe:9 of 11 1 Computer Method Summary F2 (Part 3 of 3) C -2R The Summit at PGA West - Plan 3B Lot 17 Factor R -Val. Depth Location / Comments 09/29/2002 Project Title Slab Perimeter 101 0_76 Date THERMAL MASS FOR HIGH MASS DESIGN Slab Perimeter 40 Area Thick. Heat 0 0 0 Living Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight 1,519 3.50 _—M 0.98 n/a Slab Perimeter 50 Living Zone / Slab on Grade Concrete, Heavyweight 680 3_50 28 0.98 n/a _0 2 Living Zone / Slab on Grade Concrete Hea eight 1,970 3.50 28 0.98 n/a 0 Sleeping Zone / Slab on Grade 'Concrete. Heavyweight 700 3.50 28 0.98 rda 2 Sleeping Zone / Slab on Grade PERIMETER LOSSES For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS French Door glass calculated per G-20 of Residential ECM - glass plus 2" framing. This calculation is for Base Plan 3B Lot 17. F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 101 0_76 0.0 0 Living Zone Slab Perimeter 40 0.76 0 0 0 Living Zone Slab Perimeter 205 0_76 0.0 0 Sleeping Zone. Slab Perimeter 50 0.76 0.0 0 Sleeping Zone HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 6.0 Setback LIVING HVAC Central Furnace 80%AFUE Ducts in Attic 6.0 Setback SLEEPING HVAC Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air conditioner .12 .0 SEE Ducts in Attic 6.0 Setback LIVING HVAC Split Air Conditioner 12.0 SEER Ducts in Attic 6.0 Setback SLEEPING HVAC WATER HEATING SYSTEMS Rated' Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss M) Ext A O SMITH FPCR-50-234 Small Gas Recirctfime+Temp 1 46,000 50 0.65 n/a n/a A O SMITH FPCR-50-234 Small as RecircTme+Temp 1 46.000 50 0.65 n/a n/a For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS French Door glass calculated per G-20 of Residential ECM - glass plus 2" framing. This calculation is for Base Plan 3B Lot 17. Computer Method Summary %(Addendum) C -2R The Summit at PGA West Plan 3B Lot 17 09/29/2002 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist These items require special written. justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "LIVING HVAC" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "LIVING HVAC" has R-6.0 Heating -Duct Insulation. Insulation levels above R-42 must be verified. The HVAC System "LIVING HVAC" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1519 sgft Exposed Slab Floor, 3.50" thick at Living Areas HIGH MASS Design(see C -2R) - Verify Thermal Mass: 680 sgft Covered Slab Floor, 3.50" thick at Living Areas The HVAC System "SLEEPING HVAC" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "SLEEPING HVAC" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "SLEEPING HVAC" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1970 sgft Exposed Slab Floor, 3.50" thick at Sleeping Areas HIGH MASS Design(see C -2R) - Verify Thermal Mass: 700 sgft Covered Slab Floor, 3.50" thick at Sleeping Areas HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. IPlan I Field The HVAC System "LIVING HVAC" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifrfication of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "LIVING HVAC" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "SLEEPING HVAC" includes.Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "SLEEPING HVAC" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergyPro 3.1 By EnergySoft User Number. 3412 Job Number. mtzpgaw17 1PaQe:11 of 11