0309-154 (SFD)LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
P,hapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
5;3674', R 0-7/31 /2C
Signature of Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with, licensed
contractors to construct the project (Sec. 7044, Business &, Professionals
Code).
( ) I am exempt under Section , B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
- ( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carver EXEMPT Policy No.
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section 3700 of the Labor
Code I shall forthwith comply.,with those provisions. ,
'Date:ri Applicant�` % J /.✓i.� f , a..-.�'fr
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the above-mentioned property for inspection purposes.
Signature (Owner/Agent) L Date
�.
i
BUILDING PERMIT PERMIT
03i9 -1M
DATE _ VALUATION $L'f. , 911,20 LOT I? TRACT 27767
JOB SITE-
ADDRESSr� ` %
APN 1 -,5 -0 0 -mo
OWNER "'
CONTRACTOR / DESIGNER / EN (NEER
CAN4WRTWE HC W,3, WC.
J W FAIN Y FRIC
124:" BUSEWP 3 0NTER DRIVE
12,490: LISNYSS >✓..UITER DRIVE Wfl'E 4.
'VIM, W Vi lAT, CA 92392
V1C1r0RVV 1X CA 92392
itsC1 34S• li30 CSD. T.#. :tSD
USE OF PERMIT
13;NCI E
3206 Sit SYDILOT 17if''1AN 2A-Y,.YF;@/!IT DOM' NOT fNCt UDZ BLOCK
WALI,S, P004 9PA Oh.DIRMIEWAY'.A:t'47ROA,.CH. 2001 COC,
CUSTOM C014STRUCTIOII 3,207.00 SF
PORCHIPATIO $39.06 Sir
t3AHAORif ARPORT 6 'x.40 SF
E5iiwmED C:osrr of consinucT:iON
tiY1,Q91.2 !
CONS'1'RUCTION FUR 101.000.418-,000 S11232.OD
PLAN CHECK YFZ 101-000-439-318 $►,001.95
FEE DPOSIT 101-000.4,39.318 •27s0,00
MEC'tlhA ICAI., FEF 101.000-421-000 $124.00
ELECTRICAL FRE, I01-000-120.000 $199,39
PLLIid BIT40 PUFF,101-000419-000
STRONG LOTION ICI;-1i.&SID 101.000.2,41-000 $26.519
O.�?INQ FSR 101-000-423.000 $13.00
DEVELOPER I1LIT'.ACT FEE, $2,4055 00
1 RE039 PLAN d1-OOU-�'+�11-3 15 $100.00
ART LN PUBLIC PLACES - REM[ 270.000.445-000 9172.4
CFF-'1`0TAL C:ONS'..171TIUM0;14 AND PLMT C1:1EC-1Z.
LESS PRE-PAID.FZIRD
a �
47:50.00
a
Ixi...T'IE'1�V'7E'I� 11Y9$ DOE I4OW
FEB 10 2004
CITY OF LA QUINTA
FINANCE DEPT. -
RECEIPT
DATE
BY /
DATE FINED
INSPECTOR
INSPECTION RECORD
'+ OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING
APPROVALS
MECHANICAL APPROVALS
Set Backs
�G
Underground Ducts
Forms & Footings
!
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K. to Wrap
Z! O y
F.A.U.
Framing
0a
Compressor
Insulation
Vents o
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall -Int. Lath
Final
Final
ZZ
POOLS - SPAS
BLOCKWALL APPROVALS
steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final I
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
_ /
Heater Final
Water Piping
Plumbing Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
3t �y �`'�
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
7 L 6�
Appliances
Final
C� MENTS:
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
Lot # No. Street S.F. Lot # No. Street S.F.
Unit 1 17 54174 Shoal Creek 3207 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments PGA West
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to ,
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.14 X 3,207 S.F. or $6,862.98 have been paid for the property listed above and that
building permits and/or. Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC/Desert Community Bank -William Murphy Check No. 139166
Name on the check Telephone 760/403-0425
Funding Residential
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by Sharon McGilvrey Payment Recd $0.00
$6,862.98 Over/Under
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting
Y 1
. r
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune -Palms Road
-
Q BERMUDA DUNES r
Date
2/10/04 :
La Quinta; CA 92253
rn RANCHO MIRAGE (� a
No.
25496
(760) 771-8515
INDIMDESERT ti
�.� WELLS
PALM DESERT y�
LAQUINTA
IN10 DIO
p.
Owner .
Cambridge Homes Inc
APN #
775-040-008' '
Address
12490 Business Center Drive Jurisdiction
La Quinta
City
Victorville Zip 92392
Permit #
0309-154 -
Tract #
27762
Study Area
Type
Single Family Residence
r No. of Units
1
Lot # No. Street S.F. Lot # No. Street S.F.
Unit 1 17 54174 Shoal Creek 3207 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments PGA West
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to ,
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.14 X 3,207 S.F. or $6,862.98 have been paid for the property listed above and that
building permits and/or. Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC/Desert Community Bank -William Murphy Check No. 139166
Name on the check Telephone 760/403-0425
Funding Residential
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by Sharon McGilvrey Payment Recd $0.00
$6,862.98 Over/Under
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting
Y 1
. r
t 01/08/2004 16:27 7602455987 JWFAHEKIY rHut rJ_
01/08/2005 14;59 7607715125 PGA—WEST
PAGE 02103
h _ '
ff775
a
.. , psA WEST MESIDENTIAL ASSOCiAT'10M, INC.ADJanuary 7, 2004Page 1 of 2
8-7
Cambridge Homes, Inc. —
12490 Business Center T3rivc, Suite 4
Victorville, CA 92392
'pear Sirs:
The Architectural Committee has approved your request to construct a custom home at
each of the following locations;
c-sC-54-2U_-Shoal=Creek;-Lot 8, Tract N®._27762-
• 54-282 Shoal Creek, Lot 9, Tract No. 27762
• 54-186 Shoal Crcek, Lot 16, Tract No. 27762
54-174 Shoal Creek, Lot 17, Tract No. 27762
This approval is subject to the Association being in receipt of the 540,000.00 cash deposit
or the equivalent of and the following general conditions:
n Window trim to match-ficid color. (No accent cOIOTing)
v The roofline heights for Lots R and 16 to be in accordance with the revised
submittal (sheets 1.2a. 1.3a, 1.4a, 1.2b, 1.3b and 1.41)):
u The owner is responsible for his contractors, subcontractors and material
suppliers. The PGA West Resid.entiat Association Custom 1'lome Specification
pages 30-37 should be acknowledged and the necessary inspections must be
scheduled. Adherence to the `Site Signage', Site Conduct', 'Safety Precautions',
`Site Maintenance' (otTsite), `Disposal of Site Spoils' and 'Cornpliancc' will
prevent citations is^ued 'by PGA West Security and/or the Architectural
CQmmittce.
Note: Adjacent lots must not be driven on and used without permission of the
respective lot owner. If used, 111e lots must have continuous dust control and re
establish the soil cement application. The referenced specifications sliould be
posted at each job silt%
• The construction hours are enforced according to the City of La Quinta
requirements and/or the A*.Soeiation's requirements.
. ' Work must be not conducted during tate "Bob Dope Classic Golf TOurni meat"
which will take place January 19 —25, 2004.
1'O. Box 1060, La Quinta, California 92253, Telephone 760-771-1234 FAX 760-771-5125
r 01/08/2004 16:27 7602455967
W/UtIitee5 14:59 7607715125
:': ,-
JWFANERTY HAUL UJ
PGA_WEST PAGE 03/03
Page 2 of 2
• The verification of all easements, property lijaes, setbacks and utilities are the
responsibility of the owner/contractor.
• The submittal of paint color boards, material samples of roof tiles, pavers and
other architectural treatment are subject to review and approval.
• Tbc owner is respomsible for damages done to the PGA West Residential
Association eornmon areas such as curbs, gutters and streets.
• The contractors are required to park their vehicles in accordance with the rules
and regulations of the :association.. No parking in front of mailboxe$, driveways
and fire hydrants. Do not park on both sides of the street opposite another
vehicle. This causes congestion on the street and may cause an accident.
We reserve the right to make a final inspection. An approval is based only on the
aesthetics and should not be taken as certification of construction worthiness or structural
integrity.
We appreciate your cooperation in submitting this request for approval. Should you have
any further questions regarding this matter, please feel free to contact me at the BOA
office, (760) 771.-1.234, ext. 15.
Sincerely,
Kelly cGalliard
Operations Manager
for the Architectural Committcse �� AR C
pN
KM/bvf a ZP n
cc: Architectural Committee
No. Cl l
tP REN. 8-31-05
O
��� OF CP' 4-
TANDY'S
INSPECTION INC.
PO BOX 13766
PALM DESERT, CA 92255
SPECIAL INSPECTION DAILY REPORT OFFICE/FAX 909.769.9717
PAGER 760.776.3339
TYPE OFINSPEUPq PERFORMED
n eL10 UjeL-Z lfjc.-
SAMPLE INFORMATION
DATE
,O p 'o
PHYSICAL ADDRESS
S -I? SR0INL., cle4ee_V,
PERMI NUMBER
0, 09 —1S 9 -
JOB NAMETYPE
Sf-O ~
OF STRUCTURE
.sr -o - L e T 17
ARCHITECT 2—A t34G.
ENGINEER
oeto' r -
ALCONTRACTOR
rlER:ZNfA,&P-4qe-M-� S, 3k►G
SUBCONTRACTOR
.SA�'�lo w►c.(L eL-ji--tN G
I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK,
UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS
WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS 8 APPLICABLE
BUILDING LAWS.
Le3I
INSPEC SIGNATURE
C)
&,;[_I
INSPECTORS CERTIFICATION AGENCY AND NUMBER
SAMPLE INFORMATION
SUPPLIER TICKET NUMBER
MIX NUMBER TIME AIR TEMP
SAMPLED
SAMPLE
TEMP
SLUMP TIME IN MIXER
LOCATION
WELDING INFORMATION
PROCESS f✓ , R ,
WELDERS NAME
CERTIFYING AGENCY AND CERTIFICATION NUMBER
r-ku'L-
I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK,
UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS
WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS 8 APPLICABLE
BUILDING LAWS.
Le3I
INSPEC SIGNATURE
C)
&,;[_I
INSPECTORS CERTIFICATION AGENCY AND NUMBER
_. JON TANDY
78-194 Elenbrook Ct.
Palm Desert, -CA 92211
Office (760) 772-7192
Fax (760) 772-7193
Pager (760) 776-3338
RFr1CTFRFD INSPECTOR'S WEEKLY REPORT
TYPE OF
INSPECTION
PERFORMED
O REINFORCED CONCRETETRUCT. STEEL ASSEMBLY O SSM
❑ POST TENSIONED CONCRETE O ASPHALT HER -0
O REINFORCED MASONRY O FIRE PROOFING / _ (�
JOB LOCATION .S+N O NL CAeeK k8 (,AQ J`vNrA—
REPORT SEQUENCE NO.
TYPE. OF STRUCTURE -
L.o S $ `� 1' (o l
MATERIAL DESCRIPTION
-3 0 PE-
PERMIT NO.
ARCHITECT
D E 3o
-NT. Tat -
N E,Tat-
DAY OF WEEK
HAS. CHARGED
C-ALd"
ENGINEER
ASSISTANTS
HRS. CHARGED
WSP.ECTICN GENERAL SUB
DATE CONTRACT -O.(.' �. Q_..- ;, 7 -- C:ONTAACTOR-
S qo(p
4 17
r$ -sen S Laic- -'4)
3 0
511`, a eCj&_C'o l W&- L'gv','p
c)\6
2 9ej
COPY SENT TO CLIENT O
CONTINUED ON NEXT PAGE O
PAGE OF
CERTIFICATION OF COMPLIANCE
I HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF MV
KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE
NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED
PLANS. SPECIFICATIONS. AND APPLICABLE SECTIONS OF THE
GOVERNING BUILDING LAWS.
I ATORE OF ONGISTERED INSP T R
v O o a.
ATE OF'REPORT REGISTER NUMBER
1-mll
of E4 -i
IFfl[1mmmiamm NMI
�IIImtEOIffm NMI
iii
lllmmmlmmmmlml�. �
mmism'sim-E mama
I�ms�w����o���
m—mll =MIRE= lml�
Imammmm mtml�
111
1sv
JONATHAN .L. ZANE
J%, ARCHITECTURE
958 North La Cadena Drive
Colton, CA 92324
J909) 825-7500
Attn: Sean Murphy & Bill Britten
Cambridge Homes,
12490 Business Center Drive
Victorville, CA 92392
August 24, 2004
RE: La Quinta @ PGA West — Structural walk through
To whom it may concern
This letter is to confirm our walk through at the above mentioned project on Shoal Creek Road @
PGA West in the City of La Quinta. Allhardware has been installed per plan and checked by
Richard Kline, P.E. and Jonathan L. Zane, Architect. -
If you or the inspector has any questions, please call me.
Sincere
Jonathan L. Zane
Architect
C11,046
tiG�'�Q`t�N L' ZrT�
No. C11,046
N
N. 8-31-05 Q'
O ' C AL��O
Richard Kline, P.E.
Lic. No. 30574
cc
Pty. 574 �m
P iv:
:r
hl.
Richard Kline, 13729 Ramsdell Dr., Moreno Valley, CA, (909) 452-8617
Date: January 12, 2004
Project: Cambridge Homes
54-186 Shoal Creek
La Quinta
Plan 2/-1.
Subject: TRUSS LAYOUT REVIEW/CERTIFICATION
This is to certify that I have reviewed the roof truss layout prepared by Timco Truss
Company Job No. 03478, Dated September 2, 2003 for the above referenced project. The
proposed layout is in accordance with the permitted structural drawings layout:
Review for conformance with the information given and the design concept of the project
as expressed in the.contract documents. Reviews of submittals are not conducted for the
purpose of determining the accuracy and completeness of other details, such as
dimensions and quantities, or for substantiating instructions for the installation or
performance of equipment or system. All of which remains the responsibility of the
contractor as required by the contract documents. The engineer's review of the
contractor's submittals shall not relieve the contractor from any obligation containedin
the contract documents. The engineer's review shall not constitute approval of any
construction means, methods, techniques, sequences or any safety precautions or
procedures. The engineers review of a specific item shall not indicate approval of any .
assembly of which the item is a component.
By: dam--_ Date: t l ��
R.C.E.#30574
Exp date: 3-31-04
I
f
e)
}
12
7ff7LE-24 C -HERS
Calculations By:
JUDITH B. NELSON, CEPE, CEA
MW
[En
"You're Energy Design Analysis Headquarters"
19098 Lindsay Street
Hesperia, California 92345
Voice: 1- (760) 244-6055
FAX: 1- (760) 244-1539
Email: enercalc@charter.net
Proiect Information `
RunType ........................:
Compliance
Project Title .........................:
3206 [/] South Facing SFD
Job Number .........................:
073103-3
Revision......................... :
Run Date ..............................:
August 5, 2003
TTY OF LA QUINTI A
BUILDING & SAFETY'DEPT.
APPROVED
FOR CONS UCTI , N
DATE40� BY
i
Client Name .........................: Cambridge Homes
Client Address .................: 12490 Business Center Drive #4
' Victorville, CA 92392
(760) 245-5130
CA Project Address.............:�La Quinta Plan 2-
. _N__..
Victor Valley, CA.
.I PLAN 2a
LOT 17
_ 54-174
yarry N. Nelson CEA, CEPE, C -HERS Rater SHOAL CREEK ROAD
LA QUINTA, CA
•, APN: 775-040-008-5
®114 A RM L CfF L . C 11N •be
rr
rr
CADEC
Judith B. Nelson CEA, CEPE
7 r.;
. I r L !WC �f M -,
1
t THIS PLAN INCORPORATES TIGHT DUCT
TESTING (6% DUCT LEAKAGE OR, LESS).
THIS PLAN NEEDS A THERMOSTATIC
' CONTROL VALVE (TXT INSTALLED ON A
12.0 SEER AIR-CONDITIONING SYSTEM.
THE TXV VALVE NEEDS TO BE
INSPECTED BY AN INDEPENDENT THIRD
PARTY CERTIFIED C -HERS RATER.
� THE DUCTS NEED TO BE TESTED BY A
� CERTIFIED C -HERS RATER. IT IS
RECOMMENDED THAT THE DUCTS BE
TESTED AT COMBINATION INSPECTION,
AS WELL AS AT FINAL INSPECTION. THIS
WILL ALLOW EXPOSURE OF THE DUCTS -
SO ANY REPAIRS CAN BE MADE EASILY.
THIS PLAN CALLS FOR A HIGH EFFICIENCY 75
GALLON HOT WATER HEAT WITH AN EF OF 0.48
'^Plan 2a-54-174 Shoal Creek Road
TABLE OF CONTEN STO
La Quinta, CA APN:775 040 008-5
Project Title.......... 3206 [/] SFD Date..08/06/03 14:47:41
'
2-t
�:Fs:
.---------------------
a( ��� Victor Valley, CA *v6.01* I I
******* `.J �Buildingf Permit #
t Enercalc I I
19098 Lindsay St I Plan Check / Date I
Hesperia, CA 92345 I 1
' NoIFieldCheck/Date I
Climate Zone........... 15---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -TOC I
' I User#-MP0553 User-Enercalc Run -Job # 073103-3 i
-------------------------------------------------------------------------------
TABLE OF CONTENTS
-----------------
Report Page
FORM
CF -1R ................
1
FORM
MF -1R ................
6
FORM
C -2R..................
9
HVAC
SIZING.. ...........
15
Plan 2a-54-174 Shoal Creek Road
La Quinta, CA APN:775-040-008-5
CERTIFICATE OF COMPLIANCE: RESIDENTIAL. Page 1 CF -1R
P0
Title 3206 [/] SFD Date..08/06/03 14:47:41
Pro
'ect ---------------------
*v6.01* -
. S 6 f ro Valley, CA I I
Documen a ion u ... e son, C E ******* I Building Permit #
Enercalc I 1
19098 Lindsay St I Plan Check / Date 1
Hesperia, CA 92345 I 1
No I Field Check/ Date 1
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
1 MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -FORM CF -1R
1 User#-MP0553 User-Enercalc Run -Job # 073103-3 I
-------------------------------------------------------------------------------
GENERAL INFORMATION
-------------------
Conditioned Floor Area..... 3206 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Front Facing 180 deg (S)
Number of Dwelling Units... 1
Number of Stories.......... 1
Floor Construction Type..... Slab On Grade
Glazing Percentage......... 29.9 % of floor area
Average Glazing U -factor... 0.37 Btu/hr.-sf-F
Average Glazing SHGC....... 0.32
Average Ceiling Height..... 12.3 ft
BUILDING SHELL INSULATION
Component
Frame
Cavity
Sheathing
Total
Assembly
Type
------------
Type
-------
R -value
--------
R -value
--------
R -value
-------
U -factor
-------
Location/Comments
------------------------
Wall
Wood
R-17.8
R-0
R-17.8
0.065
Exterior Walls
Wall
Wood
R-17.8
R-0
R-17.8
0.064
Garage Walls
Roof
Wood
R-11
R-27
R-38
0.025
Attic
Door
None
R-0
R-0
R-0
0.330
Solid Wood
S1abEdge
None
R-0
R-0
0.320
F2=0.760
To Outside
S1abEdge
None
R-0
R-0
Front
F2=0.510
To Garage
FENESTRATION
------------
Over-
Area
U-
Exterior
hang/
Orientation
(sf)
Factor
SHGC
Shading
Fins
Location/Comments
----------------
Wind
Front
(S)
-----
20.0
------
0.350
------
0.320
--------
Standard
-----
Yes
--------------------------
Vinyl
Low -E
Operable
Wind
Front
(S)
6.4
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Door
Front
(S)
30.0
0.400
0.320
Standard
Yes
Vinyl
Low -E
French Door
Door
Front
(S)
30.0
0.400
0.320
Standard
Yes
Vinyl
Low -E
French Door
Wind
Front
(S)
9.6
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Door
Front
(S)
30.0
0.400
0.320
Standard
Yes
Vinyl
Low -E
French Door
CERTIFICATE OF COMPLIANCE: RESIDENTIALr- Page 2 CF -1R
Project Title.......... 3206 [/] SFD Date..08/06/03 14:47:41
MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0553 User-Enercalc Run -Job # 073103-3 I
-------------------------------------------------------------------------------
FENESTRATION
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
Standard Slab 3206
Over -
Area
U-
Exterior
hang/
Orientation
(sf)
Factor
SHGC
Shading
Fins
Location/Comments
----------------
Door
Front
(S)
-----
30.0
------ ------
0.400
0.320
--------
Standard
-----
Yes
-----------------------
Vinyl
Low -E
French Door
Wind
Front
(S)
30.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Operable
Wind
Front
(S)
9.6
0.350
0.320 -Standard
Yes
Vinyl
Low -E
Fixed
Wind
Left
(W)
56.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Wind
Left
(W)
24.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Wind
Left
(W)
4.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Wind
Left
(W)
4.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Wind
Left
(W)
4.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Wind
Left
(W)
26.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Door
Left
(W)
30.0
0.400
0.320
Standard
Yes
Vinyl
Low -E
French Door
Door
Left
(W)
30.0
0.400
0.320
Standard
Yes
Vinyl
Low -E
French Door
Wind
Left
(W)
26.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Wind
Left
(W)
20.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Operable
Door
Back
(N)
110.0
0.370
0.320
Standard
Yes
Vinyl
Low -E
Patio Door
Door
Back
(N)
140.0
0.370
0.320
Standard
Yes
Vinyl
Low -E
Patio Door
Wind
Back
(N)
9.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Door
Back
(N)
105.0
0.370
0.320
Standard
Yes
Vinyl
Low -E
Patio Door
Door
Back
(N)
12.0
0.370
0.320
Standard
Yes
Vinyl
Low -E
Patio Door
Wind
Back
(N)
30.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Operable
Door
Back
(N)
30.0
0.400
0.320
Standard
Yes
Vinyl
Low -E
French Door
Wind
Right
(E)
4.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Wind
Right
(E)
4.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Wind
Right
(E)
4.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Wind
Right
(E)
5.2
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Wind
Right
(E)
5.2
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Door
Right
(E)
21.0
0.400
0.320
Standard
Yes
Vinyl
Low -E
French Door
Wind
Right
(E)
4.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Wind
Right
(E)
4.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Wind
Right
(E)
25.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Operable
Wind
Right
(E)
8.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Fixed
Wind
Right
(E)
6.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Operable
Wind
Right
(E)
12.0
0.350
0.320
Standard
Yes
Vinyl
Low -E
Operable
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
Standard Slab 3206
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... 3206 [/] SFD Date..08/06/03 14:47:41
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0553 User-Enercalc Run -Job # 073103-3
-------------------------------------------------------------------------------
HVAC SYSTEMS
------------
Refrigerant Tested ACCA
Equipment Minimum Charge and Duct Duct Duct Manual Thermostat
Type Efficiency Airflow Location R -value Leakage D Type
-------------------------------------------------------- ------ ----------
Furnace 0.800 AFUE n/a Attic R-4.2 Yes No Setback
ACSplitTXV 12.00 SEER Yes Attic R-4.2 Yes No Setback
DUCT TESTING DETAILS
--------------------
Duct Measured Supply
Leakage Target Duct Surface Area
Equipment Type (% fan CFM/CFM25) (ft2)
------------------------------------------ -----------------
Furnace / ACSplitTXV 6% / 134.7 n/a
WATER HEATING SYSTEMS
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
------------ ----------- ------------------- -------------- ------ ----------
Water Heater to meet minimum CEC Standards
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates Tested Duct Leakage.
This building incorporates either Tested Refrigerant Charge and Airflow (RCA)
or a Thermostatic Expansion Valve (TXV) on the specified air conditioning
system(s).
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF -6R installation certificate. ***
This building incorporates Tested Duct Leakage. Target CFM leakage
values measured at 25 pascals are shown in DUCT TESTING DETAILS above
or may be calculated as documented on the CF -6R. If the measured CFM
CERTIFICATE OF'COMPLIANCE: RESIDENTIAL Page 4 CF -1R
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... 3206 [/] SFD Date..08/06/03 14:47:41
-----------------------------------=-------=-----------------------------------
-------------------------------------------------------------------------------
MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -FORM CF -1R I
User#-MP0553 User-Enercaic' Run -Job # 073103-3 I
----------------------------- -------------------------------------------------
HERS REQUIRED VERIFICATION
--------------------------
is above the target, then corrective action must be taken to reduce
the duct leakage and then must be retested. Alternatively, the
compliance calculations could be redone without duct testing.
If ducts are. not installed, then HERS verification is not necessary
for Tested Duct Leakage.
This building incorporates either Tested Refrigerant Charge and Airflow (RCA)
or a Thermostatic Expansion Valve (TXV) on the specified air conditioning
system(s). If a cooling system is not installed, then HERS verification
is not necessary for the RCA or TXV.
FR� W AM41��
Kitchen, baths, laundry & utility rooms shall have at least
one luminaire with lamps of 40 lumens per watt or greater.
All fenstration products shall have a temporary label, not to
be removed before final inspection, listing the certified
U -Factor, SHGC, and certifying that the air infiltration
y�.re.qu rements'are met; or -have -la permanent label listing, the
+ U -Factor, certification organization, and rating procedures,
or a label to allow tracking back to the original certification
( information on file with the certifying organization.
All fenstrations units-shall�meet or exceed the U -Factors and
! SHGC' s listing on-' the' CF -TR -Form.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 5 CF -1R ,
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project -Title .......... -3206-[/]-SFD--------------------Date__08/06/03-14_47_41 '
MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -FORM CF -1R
----------------User#_--0553 User-Enercalc Run-Job---073103_3---------------� '
---------------------
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features
Modeling Assumptions section.
DESIGNER or OWNER
Name.... David Faylor
Company. Cambridge Homes
Address. 12490 Business Center Dr.
Victorville, CA
Phone... (760) 245-5130
License.
Signed. 1/w,Irl-I
( a e)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
(date)
DOCUMENTATION AUTHOR
Name.... Judith B. Nelson, CEPE, CEA
Company. Enercalc
Address. 19098 Lindsay St
Hesperia, CA 92345
Phone... No
Signed. �'� �3
C®rtofaed nerg(ya alyst
Judith B. Nelson
r r R 01-01-249
rr. _
CABEC
Caffornio Assoaation of Bu+!ding Energy COnsO=
Plan 2a-54-174 Shoal Creek Aoad
' La Qulnta, CA APN:775-040-008-5
MANDATORY.MEASURES CHECKLIST: RESIDENTIAL Page 6 MF -1R
Project Title.......... 3206 [/] SFD Date..08/06/03 14:47:41
' Project Address........ La Quinta Plan 2 ******* ---------------------
Victor Valley, CA *v6.01,* I I
Documentation Author... Judith B. Nelson, CEPE ******* I Building Permit #
' Enercalc I I
19098 Lindsay St I Plan Check / Date I
Hesperia, CA 92345 I 1
No I Field Check/ Date I
Climate Zone........... 15
---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
I MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -FORM MF -1R I
User#-MP0553 User-Enercalc Run -Job # 073103-3 I
-------------------------------------------------------------------------------
Note: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used'. Items marked with an
' asterisk (*) may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents, the features noted shall be considered by all parties as
minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
--------------------------
' Design- Enforce-
er ment
' *150(a): Minimum R-19 ceiling insulation.
150(b): Loose fill insulation manufacturer's labeled R -Value.
*150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U -factor in metal frame walls (does not apply
' to exterior mass walls).
*150(d): Minimum R-13 raised floor insulation in framed floors.
150(1): Slab edge insulation - water absorption rate no greater
' than 0.3%, water vapor transmission rate no greater than 2.0
perm/inch.
118: Insulation specified or installed meets insulation quality
' standards. Indicate type and form.
116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
' spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have
label with certified U -factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed.
' 150(g): Vapor barriers mandatory in Climate Zones 14 and 16
only.
150(f): Special infiltration barrier installed to comply with
Sec. 151 meets Commission quality standards.
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
' a. Closeable metal or glass door
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 7 MF -1R
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... 3206 [/] SFD Date..08/06/03 14:47:41
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -FORM MF -1R
User#-MP0553 User-Enercalc Run -Job # 073103-3
-------------------------------------------------------------------------------
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
--------------------------------------------------------------
Design- Enforce-
er ment
110-113: HVAC equipment, water heaters, showerheads and
faucets certified by the Commission.
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA.
150(1): Setback thermostat on all applicable heating and/or
cooling systems.
150(j): Pipe and Tank insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -
recirculating systems, insulated (R-4 or greater).
3. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating
sections of hot water system.
5. Cooling system piping below 55 degrees insulated.
6. Piping insulated between heating source and indirect
hot water tank.
*150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and in-
sulated, to meet the requirements of the 1998 CMC sections
601, 603, and 604, and standard 6-3; ducts insulated to a
minimum installed level of R-4.2 or enclosed entirely
in conditioned space. Openings shall be sealed
with mastic, tape, aerosol sealant, or other duct -closure
system that meets the applicable requirements of UL181,
UL181A, or UL181B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used. Building cavities shall not be used for
conveying conditioned air. Joints and seams of duct systems and
their components shall not be sealed with cloth backed rubber
adhesive duct tapes unless such tape is used in combination with
mastic and drawbands.
2. Exhaust fan systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
operated dampers.
114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 8 MF -1R
Project Title........... 3206 [/) SFD Date..08/06/03 14:47:41
MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -FORM MF -1R
User#-MP0553 User-Enercalc Run -Job # 073103-3
-------------------------------------------------------------------------------
resistance heating and no pilot light.
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch.
115: Gas-fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical cooking appliances'
with pilot < 150 Btu/hr).
LIGHTING MEASURES
-----------------
Design- Enforce-
er ment
150(k)1: Luminaires for general lighting in kitchens shall
have lamps with an efficacy of 40 lumens/watt or greater
for general lighting in kitchens. This general lighting
shall be controlled by a switch on a readily accessible
lighting control panel at an entrance to the kitchen.
150(k)2: Rooms with'a shower or bathtub must have either at
least one luminaire with lamps with an efficacy of 40
lumens/watt or greater switched at the entrance to the
room or one of the alternatives to this requirement
allowed in Sec. 150(k)2.; and, recessed ceiling fixtures
are IC (insulation cover) approved.
Pian 2a-54-174 Shoal Creek Roar!
La Quinta, CA APN:775-040-005-5
COMPUTER METHOD SUMMARY Page 9 C -2R
Project Title.......... 3206 [/] SFD Date..08/06/03 14:47:41
Project Address........ La Quinta Plan 2 ******* ---------------------
Victor Valley, CA *v6.01* 1 I
Documentation Author... Judith B. Nelson, CEPE ******* 1 Building Permit #
Enercalc I I
19098 Lindsay St 1 Plan Check / Date
Hesperia, CA 92345 I I
No I Field Check/ Date
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -FORM C -2R
1 User#-MP0553 User-Enercalc Run -Job # 073103-3
-------------------------------------------------------------------------------
----------------------------
----------------------------
MICROPAS6 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed
Compliance =
_ (kBtu/sf-yr)
_-----------------------
Design
----------
Design
----------
Margin =
---------- _
= Space Heating..........
3.66
3.48
0.18 =
- Space Cooling
39.62
37.65
1.97 =
= Water Heating..........
8.89
8.89
0.00 =
= Total
52.17
50.02
2.15 =
_ *** Building complies
-----------------------------------------------------------------
-----------------------------------------------------------------
with Computer
Performance
GENERAL INFORMATION
Conditioned Floor Area..... 3206 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Front Facing 180 deg (S)
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... ReducedYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U -factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
1
39522 cf
3206 sf
29.9 % of floor area
0.37 Btu/hr-sf-F
0.32
12.3 ft
COMPUTER METHOD SUMMARY Page 10 C -2R
Project Title........... 3206 (/] SFD Date..08/06/03 14:47:41
MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -FORM C -2R I
User#-MP0553 User-Enercalc Run -Job # 073103-3 I
-------------------------------------------------------------------------------
Floor
■ Area
Zone Type (sf)
HOUSE
Residence 3206
BUILDING ZONE INFORMATION
-------------------------
# of Vent Vent Air
Volume Dwell Cond- Thermostat Height Area Leakage
(cf) Units itioned Type (ft) (sf) Credit
39522 1.00 Yes Setback 2.0 Standard No
OPAQUE SURFACES
PERIMETER LOSSES
Area
U-
Insul
Act
Solar
Form 3
Location/
Surface
(sf)
------
factor
-----
R-val
-----
Azm
---
Tilt
----•-----
Gains
Reference
------------
Comments
----------------
--------------
HOUSE
------------
HOUSE
1
Wall
367
0.065
17.8
180
90
Yes
W.19.2X6.16
Front Wall
2
Wall,
331
0.064
17.8
180
90
No
W.19.2X6.16G
Front Garage
3
Wall
1060
0.065
17.8
270
90
Yes
W.19.2X6.16
Left Wall
4
Wall
642
0.065
17.8
0
90
Yes
W.19.2X6.16
Back Wall
5
Wall
1038
0.065
17.8
90
90
Yes
W.19.2X6.16
Right Wall
6
Wall
127
0.064
17.8
90
90
No
W.19.2X6.16G
Right Garage
7
Roof
3206
0.025
38
180
22
Yes
R.38.2X4.24T
Attic
8
Door
21
0.330
0
180
90
No
None
Solid Wood
PERIMETER LOSSES
Length
F2
Insul
Solar
Surface
(ft)
------
Factor
--------
R-val
-------
Gains
-----
Location/Comments
----------------------
------------
HOUSE
9
S1abEdge
324
0.760
R-0
No To Outside
10
SlabEdge
44
0.510
R-0
No To Garage
FENESTRATION
SURFACES
---------------------
Exterior
Area
U-
Act
Shade
Orientation
(sf)
factor
-----
SHGC
-----
Azm
---
Tilt
----
Type
--------
Location/Comments
------------------------
------------------
HOUSE
-----
1
Wind
Front
(S)
20.0
0.350
0.320
180
90
Standard
Vinyl
Low -E
Operable
2
Wind
Front
(S)
6.4
0.350
0.320
180
'90
Standard
Vinyl
Low -E
Fixed
3
Door
Front
(S)
30.0
0.400
0.320
180
90
Standard
Vinyl
Low -E
French Door
4
Door
Front
(S)
30.0
0.400
0.320
180
90
Standard
Vinyl
Low -E
French Door
5
Wind
Front
(S)
9.6
0.350
0.320
180
90
Standard
Vinyl
Low -E
Fixed
6
Door
Front
(S)
30.0
0.400
0.320
180
90
Standard
Vinyl
Low -E
French Door
7
Door
Front
(S)
30.0
0.400
0.320
180
90
Standard
Vinyl
Low -E
French Door
8
Wind
Front
(S)
30.0
0.350
0.320
180
90
Standard
Vinyl
Low -E
Operable
9
Wind
Front
(S)
9.6
0.350
0.320
180
90
Standard
Vinyl
Low -E
Fixed
10
Wind
Left
(W)
56.0
0.350
0.320
270
90
Standard
Vinyl
Low -E
Fixed
COMPUTER METHOD SUMMARY Page 11 C -2R
Project Title.......... 3206 [/] SFD Date..08/06/03 14:47:41
MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -FORM C -2R
User#-MP055.3 User-Enercalc Run -Job # 073103-3
-------------------------------------------------------------------------------
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ ----- ----- ----- --- ------------ ------------------------
11 Wind Left (W) 24.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed
12 Wind Left (W) 4.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed
13 Wind Left (W) 4.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed
14 Wind Left (W) 4.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed
15 Wind Left (W) 26.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed
16 Door Left (W) 30.0 0.400 0.320 270 90 Standard Vinyl Low -E French Door
17 Door Left (W) 30.0 0.400 0.320 270 90 Standard Vinyl Low -E French Door
18 Wind Left (W) 26.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed
19 Wind Left (W) 20.0 0.350 0.320 270 90 Standard Vinyl Low -E Operable
20 Door Back (N) 110.0 0.370 0.320 0 90 Standard Vinyl Low -E Patio Door
21 Door Back (N) 140.0 0..370 0.320 0 90 Standard Vinyl Low -E Patio Door
22 Wind Back (N) 9.0 0.350 0.320 0 90 Standard Vinyl Low -E Fixed
23 Door Back (N) 105.0 0.370 0.320 0 90 Standard Vinyl Low -E Patio Door
24 Door Back (N) 12.0 0,.370 0.320 0 90 Standard Vinyl Low -E Patio Door
25 Wind Back (N) 30.0 0.350 0.320 0 90 Standard Vinyl Low -E Operable
26 Door Back (N) 30.0 0.400 0.320 0 90 Standard Vinyl Low -E French Door
27 Wind Right (E) 4.0 0.350 0.320 90 90 Standard Vinyl Low -E Fixed
28 Wind Right (E) 4.0 0.350 0.320 90 90 Standard Vinyl Low -E Fixed
29 Wind Right (E) 4.0 0.350 0.320 90 90 Standard Vinyl Low -E Fixed
30 Wind Right (E) 5.2 0.350 0.320 90 90 Standard Vinyl Low -E Fixed
31 Wind Right (E) 5.2 0.350 0.320 90 90 Standard Vinyl Low -E Fixed
32 Door Right (E) 21.0 0.400 0.320 90 90 Standard Vinyl Low -E French Door
33 Wind Right (E) 4.0 0.350 0.320 90 90 Standard Vinyl Low -E Fixed
34 Wind Right (E) 4.0 0.350 0.320 90 90 Standard Vinyl Low -E Fixed
35 Wind Right (E) 25.0 0.350 0.320 90 90 Standard Vinyl Low -E Operable
36 Wind Right (E) 8.0 0.350 0.320 90 90 Standard Vinyl Low -E Fixed
37 Wind Right (E) 6.0 0.350 0.320 90 90 Standard Vinyl Low -E Operable
38 Wind Right (E) 12.0 0.350 0.320 90 90 Standard Vinyl Low -E Operable
OVERHANGS AND SIDE FINS
-----------------------
---Window-- ------Overhang----- ---Left Fin--- ---Right Fin --
Area Left Rght
Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
----------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
HOUSE
1 Window 20.0 n/a 5.0 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a
2 Window 6.4 n/a 1.6 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a
3 Door 30.0 n/a 10.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a
4 Door 30.0 n/a 10.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a
5 Window 9.6 n/a 1.6 1.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a
6 Door 30.0 n/a 10 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a
7 Door 30.0 n/a 10 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a
8 Window 30.0 n/a 5.0 1.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a
COMPUTER METHOD SUMMARY Page 12 C -2R
-------------------------------------------------------
Project Title.......... 3206 [/] SFD Date..08/06/03 14:47:41
MICROPAS6 v6.01 File -07310.33 Wth-CTZ15S92 Program -FORM C -2R
User#-MP0553 User-Enercalc Run -Job # 073103-3 i
-------------------------------------------------------------------------------
OVERHANGS AND SIDE FINS
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
HOUSE
Standard Slab 3206
---Window--
------Overhang-----
---Left Fin---
---Right
Fin --
Area
Left
Rght
Surface
(sf)
Wdth
Hgth
Dpth
Hght
Ext
Ext
Ext
Dpth
Hght
Ext
Dpth
Hght
----
-----------
9
Window
-----
9.6
-----
n/a
-----
1.6
----
1.0
----
0.0
----
n/a
----
n/a
----
n/a
----
n/a
----
'n/a
--------
n/a
'n/a
n/a
10
Window
56.0
n/a
8.0
18.0
1.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
11
Window
24.0
n/a
3.0
1.0
3.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
12
Window
4.0
n/a
2.0
1.0
2.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
13
Window
4.0
n/a
2.0
1.0
2.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
14
Window
4.0
n/a
2.0
1.0
2.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
15
Window
26.0
n/a
10.0
1.0
1.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
16
Door
30.0
n/a
10.0
1.0
1.0
n/a
n/a
n/a
..n/a
n/a
n/a
n/a
n/a
17
Door
30.0
n/a
10.0
1.0
1.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
18
Window
126.0
n/a
10.0
1.0
1.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
19
Window
20.0
n/a
5.0
1.0
1.0
_n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
20
Door
110.0
n/a
10.0
7.0
1.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
21
Door
140.0
n/a
10.0
7.0
1.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
22
Window
9.0
n/a
3.0
7.0
1.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
23
Door
105.0
n/a
10.0
14.0
1.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
24
Door
12.0
n/a
3.0
1.0
1.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
25
Window
30.0
n/a
10.0
1.0
1.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
26
Door
30.0
n/a
10.0
1.0
1.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
27
Window
4.0
n/a
2.0
1.0
3.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
28
Window
4.0
n/a
2.0
1.0
3.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
29
Window
4.0
n/a
2.0
1.0
3.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
30
Window
5.2
n/a
2.0
1.0
3.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
31
Window
5.2
n/a
2.0
1.0
3.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
32
Door
21.0
n/a
7.0
1.0
3.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
33
Window
4.0
n/a
2.0
1.0
3.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
34
Window
4.0
n/a
2.0
1.0
3.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
35
Window
25.0
n/a
5.0
1.0
3.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
36
Window
8.0
n/a
1.6
1.0
1.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
37
Window
6.0
n/a
3.0
1.0
3.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
38
Window
12.0
n/a
4.0
1.0
3.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
HOUSE
Standard Slab 3206
COMPUTER METHOD SUMMARY
Page 13
C -2R ■
-------------------------------------------------------------------------------
Project
..........
,
-Title
MICROPAS6
-3206-[/]-SFD--------------------Date..08/06/03-14_47_41
v6.01 File -0731033 Wth-CTZ15S92 Program
-FORM C -2R
-------------------------------------------------------------------------------
User#-MP0553 User-Enercalc
Run -Job #
073103-3
HVAC SYSTEMS
------------
Refrigerant
Tested ACCA
i
System
Minimum Charge and Duct
Duct
Duct Manual
Duct
Type
Efficiency Airflow Location
R -value
Leakage D
Eff
HOUSE
Furnace
0.800 AFUE n/a Attic
R-4.2
Yes No
0.815
ACSplitTXV
12.00 SEER Yes Attic
R-4.2
Yes No
0.703
DUCT TESTING DETAILS
--------------------
Duct Measured Supply
Leakage Target Duct Surface Area
Equipment Type (% fan CFM/CFM25) (ft2) ,
------------------------------------------ -----------------
HOUSE
Furnace / ACSplitTXV 6% / 134.7 n/a
WATER HEATING SYSTEMS
---------------------
Number Tank External
in Energy Size Insulation '
Tank Type Heater Type Distribution Type System Factor (gal) R -value
------------ ----------- ------------------- -------------- ------ ----------
Water Heater to meet minimum CEC Standards ,
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans,
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates Tested Duct Leakage. I
This building incorporates either Tested Refrigerant Charge and Airflow (RCA)
or a Thermostatic Expansion Valve (TXV) on the specified air conditioning I system(s)
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF -6R installation certificate. ***
This building incorporates Tested Duct Leakage. Target CFM leakage i
values measured at 25 pascals are shown in DUCT TESTING DETAILS above
or may be calculated as documented on the CF -6R. If the measured CFM
COMPUTER METHOD SUMMARY Page 14 C -2R
Project Title Title.......... 3206 [/] SFD Date..08/06/03 14:47:41
MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -FORM C -2R I
User#7MP0553 User-Enercalc Run -Job # 073103-3 I
-------------------------------------------------------------------------------
HERS REQUIRED VERIFICATION
--------------------------
is above the target, then corrective action must be taken to reduce
the duct leakage and then must be retested. Alternatively, the
compliance calculations could be redone without duct testing.
If ducts are not installed, then HERS verification is not necessary
for Tested Duct Leakage.
This building incorporates either Tested Refrigerant Charge and Airflow (RCA)
or a Thermostatic Expansion.Valve (TXV) on the specified air conditioning
system(s). If a cooling system is not installed, then HERS verification
is not necessary for the RCA or TXV.
REMARKS
Kitchen, baths, laundry & utility rooms shall have at least
' one luminaire with lamps of 40 lumens per watt or greater.
All fenstration products shall have a temporary label, not to
' be removed before final inspection, listing the certified
U -Factor, SHGC, and certifying that the air infiltration
requirements are met; or have a permanent label listing, the
' U -Factor, certification organization, and rating procedures,
or a label to allow tracking back to the original certification
information on file with the certifying organization.
' All fenstrations units shall meet'or exceed the U -Factors and
SHGC's listing on the CF -1R Form.
Plan 2a-54-174 Shoal Creek Road
La Quinta, CA APN:775-040-008-5
HVAC SIZING Page 15 HVAC
Project Title.......... 3206 [/] SFD Date..08/06/03 14:47:41
Project Address........ La Quinta Plan 2 ******* ---------------------
Victor Valley, CA *v6.01* I I
Documentation Author... Judith B. Nelson, CEPE ******* I Building Permit #
Enercalc I 1
19098 Lindsay St I Plan Check / Date I
Hesperia, CA 92345 I 1
No I Field Check/ Date I
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
MICROPAS6 v6.01 File -0731033 Wth-CTZ15S92 Program -HVAC SIZING I
I User#-MP0553 User-Enercalc Run -Job # 073103-3 1
-------------------------------------------------------------------------------
GENERAL INFORMATION
-------------------
Floor Area ................. 3206 sf
Volume ..................... 39522 cf
Front Orientation.......... Front Facing 180 deg (S)
Sizing Location............ RIVERSIDE EXP STATION
Latitude ................... 34 degrees
Winter Outside Design...... 34 F
Winter Inside Design....... 70 F
Summer Outside Design...... 102 F
Summer Inside Design....... 78 F
Summer Range ............... 36 F
Interior Shading Used...... No
Exterior Shading Used...... No
Overhang Shading Used...... No
Latent Load Fraction....... 0.20
HEATING AND COOLING LOAD SUMMARY
Heating Cooling
Description (Btuh) (Btuh)
-------------------------------------------------------
Opaque Conduction and Solar......
21169
8528
Glazing Conduction ...............
12751
8501
Glazing Solar .....................
n/a
13977
Infiltration .....................
19310
8212
Internal Gain ....................
n/a
2100
Ducts ............................
5323
4132
Sensible Load ....................
58552
45449
Latent Load ......................
n/a
9090
-----------
Minimum Total Load
58552
-----------
54539
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.