Loading...
0309-152 (SFD)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty ofperjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and ,Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date 536747 B 07/;31 M Date Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. r ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier EXEMPT Policy No. (This. section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions.�T ,✓ %ate: 2 -IA -e-41 Applicant _�' Warning: Failure to secure Workers' Compensation coverag is u;nlAful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. Signature (Owner/Agent);Z1*',4 9 1 Date.,I BUILDING PERMIT PERMITk DATE - , v LUATION LOT -a TRACT 4,51.7.70 0 771767. r,�_ iT �.. JOB SITE v ADDRESS QAI'Z: r APN 771S .l � -t0008 OWNER CONTRACTOR/DESIGNER/EN (NEER CANL8RMCFE 1.10WS', WC. J w :FISkTl;E2:! r We 12490 B UZ.WFM 4&NT1?<l:i.l'�1�I.V ' 12490 BLMN10 3 CEJ'.0 I7)RTVE SUM,4 VIC1OPV.1 JUE CA :923.02 V1C17C:,►1��ii'.L CA 92392 USE OF PERMIT SINGlY FAWAr DWEIIA40 39.793F SSFIDI OT RVLAN IAIPE1Z: IT fDCO&S NOT INCLUDE Bl/'CK WALLS, POOLY SPA. OR DRJV'FW.A,Y APPROACH, 2001 CDC. CUSTOM CONSTRUCTION 3,3'n.00 OF PORCk dPATIO 648.00 Safi' CIARACF1rARPORT 662.00 3P IFIFTMWIRI) COST 01! COXISMT MON 284,017.70 PP IM, 1x' 119,,E s1'am"Ry CONSTRUCTION ",F< 1101-000418-000 $1,287.00 � PLAN CHECK FEY, 101-000-439-318 $;,041.65 RZ DEPOSIT . 101.000.439-31.8 47SO106 fylWt Aa4ICIAII FEE 101-f00,421-000 1 $93.00 BLEC"THIC'.A1l FKF.. 101.000.420.000 '' $206,31 PLUMS-INOFEE 101-000-419-000 $181.25 ST 0140 MOT4f�141EF - AZION 3 101-000-241.000 !$28.48 GRAMINCt PEP, 101-000-423-000 DEVELOPER IMPACT FEE T2,403,00 P14I,:II;3, PL&N 101-000-441-344 $100.00 APST R4 PU8L4C PLACES -RUIE 270-000-445.000 $212,04 S1 UB -T01 AL CO2 MILT CTfO'+T AND PLAN (:'1 I K $5,574.93 LESS PI�.E PAID F 4750,00 1:, § _U4A 3'F7SFS DUE .t`3'O11VT. "FINAN(Ic RECEIPT DATE) . , (1' u � BY �r DATE FINAZD �� INSPECTORI INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION I DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings . _ Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing 6 Compressor Insulation b Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath d Drywall - Int. Lath G' Final Final L BLOCKWALL APPROVALS. POOLS - SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines. 2 �y Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection z Encapsulation Gas Piping Gas Test 2 Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring d Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final 7 2 z ZE Utility Notice (Perm) COMM)EnS: �� z3 TANDY'S INSPECTION INC. PO BOX 13766 PALM DESERT, CA 92255 SPECIAL INSPECTION DAILY REPORT OFFICE/FAX 909.769.9717 PAGER 760.776.3339 TYPE OF INSPECTION PERFOfiWD SAMPLE INFORMATION SUPPLIER DAT PHYSICAL ADDRESS ek L, PERMIT NUMBER v,.-TF� 03,09- fsa— JOB NAME -s 'Fib. TYPE OF STRUCTURE Fts L OT• O ARCHITECT -zN oe- E"GEER IC l AAx—A t W GENERAL CONTRACTOR I ` •��11 SUB CONTRACTOR 1 I 1 OF WORK INSPECTED rti I HEREBY CERTIFY THAT 1 HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS. CC: INSPECTORS SIGNATU .,gra O INSPECTORS CERTIFlCATION AGENCY AND NUMBER SAMPLE INFORMATION SUPPLIER TICKET NUMBER MIX NUMBER TIME SAMPLED AIR TEMP I SAMPLE TEMP SLUMP TIME IN MIXER LOCATION WELDING INFORMATION PROCESSt WELDERS NAME CERTIFYING AGENCY AND CERTIFICATION NUMBER '01" 6, mi a Ll A. C LLL oZ(ob I HEREBY CERTIFY THAT 1 HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS. CC: INSPECTORS SIGNATU .,gra O INSPECTORS CERTIFlCATION AGENCY AND NUMBER CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Date 2/10/04 La Quinta, CA 92253 No. 25493 (760) 771-8515 , Owner Cambridge Homes Inc APN # Address 12490 Business Center Drive Jurisdiction City Victorville Zip 92392 Permit # Tract # 27762 Study Area Type Single Family Residence No. of Units Lot # Unit 1 8 Unit 2 Unit 3 Unit 4 Unit 5 No. Street 54294 Shoal Creek Comments PGA West S.F. 3379 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Q BERMUDA DUNES r rn RANCHO MIRAGE {� INDIAN WELLS v �iPALM DESERT � y� LA QUINTA ,.�. QINDIO `11 O 775-060-008 La Quinta 0309-152 1 Lot # No. Street - S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: - EXEMPTION NOT APPLICABLE This. certifies_ that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. , in the amount of $2.14 X 3,379 S.F. or $7,231.06 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Desert Community Bank -William Murphy Check No. 139165 Name on the check Telephone 760/403-0425 Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted by Sharon MCGilvrey Payment Recd = $0.00 $7,231.06 Over/Under Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed. Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting ecr_icTCRFn INSPECTOR'S WEEKLY REPORT JON TANDY 78-194 Elenbrook Ct. Palm Desert, CA 92211 t Office (760) 772-7192 Fax (760) 772-7193 Pager (760) 776-3338 TYPE OF INSPECTION PERFORMED ❑ REINFORCED CONCRETETRUCT. STEEL ASSEMBLY S ❑ POST TENSIONED CONCRETE ❑ ASPHALT HER ❑ REINFORCED MASONRY O FIRE PROOFING / JOB LOCATION A�ee�/ Q J J`v\T REPORT SEQUENCE N0. TYPE . 5 OF STRUCTURE• Q 9' Gf� l 1 MATERIAL DESCRIPTION -3 t - PERMIT NO. ARCHITECT D E �O IN E.T12 IQ DAY OF WEEK NRS. CHARGED _ ENGINEER ASSISTANTS HRS. CHARGED INSPECTION GENERAL ,,..--QQ SUB GATE CONTRAGT.O. Q - : Y�"t. ___ CONTRACTOR_iFi_�L. -- _ tes (9 Sqo �Lio11 r7 �pp 1&SeR _& 1 W e't-el*• Cs C3.1-, Ci0 `S 3o Sem ArTrPVc942-3c� S a a.i.i) l w&- C"gE:'vv-(3 etAe.t = S V c:*+TP, t ro a - o -- - �b co COPY SENT TO CLIENT O CONTINUED ON NEXT PAGE O PAGE OF CERTIFICATION OF COMPLIANCE 'HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF MV KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS. SPECIFICATIONS. AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS. 1 AT RE OF EGISTEREO INSP T R LA v O o a, ATE OF REPORT REGISTER NUMBER NMI JONATHAN L. ZANE . ARCHITECTURE 958 North La Cadena Drive Colton, CA 92324 (909) 825-7500 Attn: Sean Murphy & Bill Britten Cambridge Homes 12490 Business Center Drive Victorville, CA 92392 August 24, 2004 RE: La Quinta @ PGA West — Structural walk through To whom it may concern This letter is to confirm our walk through at the above mentioned project on Shoal Creek Road @ PGA West in the City of La Quinta. All hardware has been installed per plan and checked by Richard Kline, P.E. and Jonathan L. Zane, Architect. If you or the inspector has any questions, please call me. Sincere Jonathan L. Zane Architect C11,046 9 Act No. C11,046 REN. 8-31-05 4 ti OF CALl�� Richard Kline, P.E. Lic. No. 30574 Y ~mUf LL Z a NO -30574 m m Exp. C/v11. -9 OF C' 1� TITLE -24 / C -HERS �7Calculations By: p JDITH B., NELSON, CEDE, CEA "You're Energy Design Analysis Headquarters" 19098 Lindsay Street Hesperia, California 92345 Voice: 1- (760) 244-605! FAX: 1- (760) 244-1539 Email: enercalc a*charter.: CITY OF LA QUINTA BUILDING & SAFETY DEPT. 't APPROVED FOR CONSTRICTION Project Information Run Type ........................: Compliance DATE Project Title .........................: 3379 1l South Facing SF5 Job Number .........................: 073103-1 Revision......................... : Run Date ..............................: August 5, 2003 Client Name .........................: Cambridge Homes Client Address................: 12490 Business Center Drive #4 Victorville, CA 92392 (760) 245-5130 CA Project Address .............: La Quinta Plan 1 Victor Valley, CA I Lara N. Nelson CEA, CEPE, C -HERS Rat q 54' Z" MeotJ c tr4* PLAN ]a LOT 8 54-294 SHOAL CREEK ROAD LA QUINTA, CA APN: 775-060-008-7 C.Aep6W GERTIF.ItWENERGY NACYST= Judith B. Nelson CEA, CEPE e ?��C��X?�YX�i:YYY7CYYY`�.YY�Y?CYX'sCY7: a:Y� °Y.Y?C3�C�:YY °Y.�:�:Y THIS PLAN INCORPORATES TIGHT DUCT TESTING (6% DUCT LEAKAGE OR LESS). THIS PLAN NEEDS A THERMOSTATIC CONTROL VALVE (TXT INSTALLED ON A 12.0 SEER AI12-CONDITIONING SYSTEM. THE TXV VALVE NEEDS TO BE INSPECTED BY AN INDEPENDENT THIRD PARTY CERTIFIED C -HERS RATER. THE DUCTS NEED TO BE TESTED BY A CERTIFIED C -HERS RATER. IT IS RECOMMENDED THAT THE DUCTS BE TESTED AT COMBINATION INSPECTION, AS WELL AS AT FINAL INSPECTION. THIS WILL ALLOW EXPOSURE OF THE DUCTS SO ANY REPAIRS CAN BE MADE EASILY. :�"�."J:'�:X'}:XXY.XY.X...•..Y.Y.Y...XXY.XXXX.•Y.Y.XX..X..Y.XY.Y.XXXY.:•..•.•. Y.X. THIS PLAN CALLS FOR A HIGH EFFICIENCY 75 GALLON HOT WATER HEAT WITH AN EF OF 0.48 Plan la -54-294 Shoal Creek Road TABLE OF CONTENTS La Quilnta, CA APN:775-O60-008-7 TOC ____________________________ Project Title..:....... 3379 [/] SFD Date..08/06/03 14.48.36 Project Address........ La Quinta Plan 1 ******* ---------------------- Victor Valley, CA *v6.01* I I Documentation Author... Judith B. Nelson;' CEPE ******* I Building Permit # Enercalc I I 19098 Lindsay St I P1an.Check / Date I Hesperia, CA 92345 I I No I Field Check/ Date I Climate Zone........... 15 -------------- ---- Compliance Method...... MICROPA86 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01. File -0731031 Wth-CTZ15S92' Program -TOC' I User#7MP0553 User-Enercalc Run -Job .# 073103-1 I ---=---------------------------=----------------------------------------------- TABLE OF CONTENTS ----------------- Report Page FORM CF -1R ................. .1 FORM MF -1R................. 6 FORM C -2R ................. 9 HVAC SIZING............... 16 Pian 1a-54-294 Shoal Creek Road CERTIFICATE adFCOMPLI7�NC :4299 ENT IAL Page 1 CF-1R Project Title.......... 3379 [/] SFD Date..08/06/03 14:48:36 Project Address........ La Quinta Plan 1 ******* --------------------- Victor Valley, CA *v6.01* I I Documentation Author... Judith B. Nelson, CEPE ******* I Building Permit # I Enercalc I I = 19'098 Lindsay St I Plan Check / Date I Hesperia, CA 92345 I I No I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. I MICROPAS6 v6.01 File-0731031 Wth-CTZ15S92 Program-FORM CF-1R I I User#-MP0553 User-Enercalc Run-Job # 073103-1 I ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Conditioned Floor Area..... 3379 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 180 deg (S) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 29.6 % of floor area Average Glazing U -factor... 0.39 Btu/hr-sf-F Average Glazing SHGC....... 0.34 Average Ceiling Height..... 12 ft BUILDING SHELL INSULATION Component Frame Cavite Sheathing Total Assembly Type ------------ Type ------- R -value R -value R -value U -factor Location/Comments Wall Wood -------- R-17.8 -------- R-0 ------- R-17.8 ------- ------------------------ 0.065 Exterior Walls Wall Wood R-17.8 R-0 R-17.8 0.064 Garage Walls Roof Wood R-11 R-27 R-38 0.025 Attic Door None R-0 R-0 R-0 0.330 Solid Wood S1abEdge None R-0 R-0 Operable F2=0.760 To Outside S1abEdge None R-0 R-0 0.320 F2=0.510 To Garage FENESTRATION Over - Area U_ Exterior hang/ Orientation ---------------- (sf) ----- Factor ------ SHGC Shading Fins Location/Comments Wind Front (S) 30.0 0.350 ------ 0.320 -------- Standard ----- Yes -------------------------- Vinyl Low -E Operable Wind Front (S) 9.6 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Front (S) 16.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Front (S) 16.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Door Front (S) 28.0 0.400 0.320 Standard Yes Vinyl Low -E French Door Door Front (S) 28.0 0.400 0.320 Standard Yes Vinyl Low -E French Door CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... 3379 (/] SFD Date..08/06/03 14:48:36 MICROPAS6 v6.01 File -0731031 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0553 User-Enercalc Run -Job # 073103-1 I ------------------------------------------------------------------------------- FENESTRATION ------------ Over- Area U- Exterior hang/ Orientation (sf) Factor SHGC Shading Fins Location/Comments ---------------- ----- ------ -------------- ----- -------------------------- Wind Left (W) 20.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Left (W) 35.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Left (W) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Left (W) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Left (W) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Left (W) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Left (W) 4.0 0.350 0.320 Standard Yes Vinyl.Low-E Fixed Door Left (W) 21.0 0.400 0.320 Standard Yes Vinyl Low -E French Door Wind Left (W) 5.0 0.350. 0.320 Standard Yes Vinyl Low -E Fixed Wind Left (W) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Left (W) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Left (W) '4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Left (W) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed. Door Left (W) 21.0 0.400 0.320 Standard Yes Vinyl Low -E French Door Door Left (W) 21.0 0.400 0.320 Standard Yes Vinyl Low -E French Door Wind Left (W) 18.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Left (W) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Left (W) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Left *(W) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Left (W) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Door Back (N) 115.0 0.370 0.320 Standard Yes Vinyl Low -E Patio Door Wind Back (N) 20.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Door Back (N) 140.0 0.370 _0.320 Standard Yes Vinyl Low -E Patio Door Wind Back (N) 35.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Door Back (N) 140.0 0.370 0.320 Standard Yes Vinyl Low -E Patio Door Door Back (N) 21.0 0.400 0.320 Standard Yes Vinyl Low -E French Door Wind Right (E) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Right (E) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Right (E) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Right (E) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Right (E) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Right (E) 35.0 0.870 1.000 Standard Yes Glass/Acrylic Block Wind Right (E) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Right (E) 25.0 0.350 0.320 Standard Yes Vinyl Low -E Operable Wind Right (E) 5.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Right (E) 4.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed Wind Right (E) 9.0 0.350 0.320 Standard Yes Vinyl Low -E Operable Wind Right (E) 5.0 0.350 0.320 Standard Yes Vinyl Low -E Operable Door Right (E) 35.0 0.370 0.320 Standard Yes Vinyl Low -E Patio Door Wind Right (E) 5.0 0.350 0.320 Standard Yes Vinyl Low -E Operable Door Right (E) 21.0 0.400 0.320 Standard Yes Vinyl Low -E French Door Door Right (E) 21.0 0.400 0.320 Standard Yes Vinyl Low -E French Door Wind Right (E) 18.0 0.350 0.320 Standard Yes Vinyl Low -E Fixed CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... 3-379 [/] SFD Date..08/06/03 14:48:36 I MICROPAS6 v6.01 File -0731031 Wth-CTZ15S92 Program -FORM CF -1R I User#-MP0553 User-Enercalc Run -Job # 073103-1 ------------------------------------------------------------------------------- SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 3379 HVAC SYSTEMS WATER HEATING SYSTEMS --------------------- Number in Tank Type Heater Type Distribution Type System ------------ ----------- ------------------- ------ Water Heater to meet minimum CEC Standards Tank External Energy Size Insulation Factor (gal) R -value -------- ------ ---------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** ** verified during plan check and field inspection. *** This building incorporates Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TX_V) on the specified air conditioning system(s). Refrigerant Tested ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type ------------------------ Efficiency Airflow Location R -value ------------------------- Leakage ------- D ------ Type ---------- Furnace 0.800 AFUE n/a Attic R-4.2 Yes No Setback ACSplitTXV 12.00 SEER Yes Attic R-4.2 Yes No Setback DUCT TESTING DETAILS -------------------- Duct Measured Supply Leakage Target Duct Surface Area Equipment ------------------------ Type (': fan CFM/CFM25) ------------------ (ft2) Furnace ----------------- / ACSplitTXV 6'--:: / 141.9 n/a WATER HEATING SYSTEMS --------------------- Number in Tank Type Heater Type Distribution Type System ------------ ----------- ------------------- ------ Water Heater to meet minimum CEC Standards Tank External Energy Size Insulation Factor (gal) R -value -------- ------ ---------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** ** verified during plan check and field inspection. *** This building incorporates Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TX_V) on the specified air conditioning system(s). CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page.4 CF -1R Project Title.....:.... 3379 [/] SFD Date..08/06/03 14:48:36 MICROPAS6 v6.01 File -0731031 Wth-CTZ15S92 Program -FORM CF -1R i User#-MP0553 User-Enercalc Run -Job # 073103-1 I ------------------------------------------------------------------------------- HERS REQUIRED "VERIFICATION *** Items in this section require field testing and/or' *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** ** CEC approved testing and/or verification methods and *** *** must be reported on the CF -6R installation certificate. *** This building incorporates Tested Duct Leakage. Target CFM leakage values measured at 25 pascals are shown in DUCT TESTING DETAILS above or may be calculated as documented on the CF -6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary for Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS Kitchen,•baths, laundry & utility rooms shall have at least one luminaire with'lamps.of 40 lumens per watt or greater. ****** All fenstration products sha--. have a temporary label, not to "beri�FmoVed before final inspection, .listing the certified U_ Factor, SHGC, and certifying that the air infiltration requirements are met; or have a permanent label listing, the U -Factor, certification organization, and rating procedures, or a label to allow.tracking back to the.original certification information on file with the certifying organization. ****** All fenstrations units shall meet or exceed the U -Factors and SHGC's listing on the CF -1R Form. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 5 CF -1R Project Title.......... 3379 [/] SFD Date..08/06/03 14:48:36 MICROPAS6 v6.01 File -0731031 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0553 User-Enercalc Run -Job # 073103-1 ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER Name.... David Faylor Company. Cambridge Homes Address. 12490 Business Center Dr. Victorville, CA Phone... (760) 245-5130 License. Signed date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Judith B. Nelson, CEPE, CEA Company. Enercalc Address. 19098 Lindsay St Hesperia, CA 92345 Phone... No Signed.. 2 orti ed Energla*halyst Judkh 8. Nelson r r R 01-01-249 r C A B E C C090wo As 609, 06 of Dur ding Energy Cawknw Plan is -54-294 Shoal Creek Road La Quinta, CA APN:775-060-008-7 MANDATORY MEASURES CHECKLIST.: RESIDENTIAL Page 6 MF -1R Project Title.......... 3379 [/] SFD Date..08/06/03 14:48:36 Project Address........ La Quinta Plan 1 ******* --------------------- Victor Valley, CA *v6.01* I I Documentation Author... Judith B. Nelson, CEPE ******* I Building Permit # Enercalc I I 19098 Lindsay St I Plan Check / Date I Hesperia, CA 92345 I 1 No I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.' ------------- MICROPAS6 v6.01 File -0731031 Wth-CTZ15S92 Program -FORM MF -1R User#-MP0553 User-Enercalc Run -Job # 073103-1 I ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. I150(b): Loose fill insulation manufacturer's labeled R -Value. *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -factor, certified Solar Heat Gain Coefficient (SHGC),.and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 7 MF -1R Project Title.......... 3379 [/] SFD Date..08/06/03 14:48:36 MICROPAS6 v6.01 File -0731031 Wth-CTZ15S92 Program -FORM MF -1R I User#-MP0553 User-Enercalc Run -Job # 073103-1 ------------------------------------------------------------------------------- b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES ----------------------------------------------------------- Design- Enforce- er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. 150(1): Setback thermostat on all applicable heating and/or cooling systems. 150(j): Pipe and Tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. 6. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC sections 601, 603, and 604, and standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 8 MF -1R• ------------------- Project Title.......... 3379 [/] SFD Date..08/06/03 14:48:36 ---------------------------- MICROPAS6 v6.01 File -0731031 Wth-CTZ15S92 Program -FORM MF -1R User#-MP0553 User-Enercalc Run -Job # 073103-1 I 7 ---------------------------------------------------------------------- resistance heating and no pilot light. 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool.system has directional inlets and 'a circulation pump time switch. 115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr). LIGHTING MEASURES ----------------- Design- Enforce- er ment 150(k)'1: Luminaires for general lighting in kitchens shall ' have lamps with an.efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible -lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps.with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement allowed in Sec. 150(k)2.; and recessed.ceiling fixtures are IC (insulation cover) approved. Plan 1a-54-294 Shoal Creek Road La COMPUTER METHbD A AMPMARY75-060-008-7 Page 9 C -2R Project Title.......... 3379 [/1 SFD Date..08/06/03 14:48:36 ******* Project Address........ La Quinta Plan 1 --------------------- C Victor Valley, CA *v6.01* 1 1 Documentation Author... Judith B. Nelson, CEPE ******* I Building Permit # Enercalc 19098 Lindsay St I Plan Check / Date 1 Hesperia, CA 92345 I I No I Field Check/ Date 1 Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. 1 MICROPAS6 v6.01 File -0731031 Wth-CTZ15S92 Program -FORM C -2R I User#-MP0553 User-Enercalc Run -Job #'073103-1 1 ------------------------------------------------------------------------------- MICROPAS6 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) _----------------------- Design ---------- Design ---------- Margin = ---------- - = Space Heating.......... 3.34 3.34 0.00 = = Space Cooling.......... 37.80 37.36 0.44 = = Water Heating.......... 8.43 8.43' 0.00 = = Total 49.57 49.13 0.44 = _ *** Building complies with Computer Performance GENERAL INFORMATION Conditioned Floor Area..... 3379 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 180 deg (S) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 40716 cf 3379 sf 29.6 % of floor area 0.39 Btu/hr-sf-F 0.34 12 ft COMPUTER METHOD SUMMARY Page 10 C -2R ----------- Project Title.......... 3379 [/] SFD Date..08/06/03 14:48:36 MICROPAS6 v6.01 File -0731031 Wth-CTZ15S92 Program -FORM C -2R User#-MP0553 User-Enercalc Run -Job # 073103-1 I ------------------------------------------------------------------------------- BUILDING ZONE INFORMATION Floor. # of Vent Vent Air Area Volume, Dwell Cond- Thermostat Height Area Leakage Zone Type (sf) ----- (cf) Units itioned Type ------- ----------------------- (ft) ----- (sf) -------- Credit --------- -------------- HOUSE Reference ------------ Comments ---------------- -------------- HOUSE Location/Comments ----------------------' Residence 3379 40716 1.00 Yes Setback 2.0 Standard No OPAQUE SURFACES PERIMETER LOSSES Area U- Insul Act Insul Solar Form 3 Location/ Surface (sf) ------ factor ----- R-val ----- Azm --- Tilt Gains ---- ----- Reference ------------ Comments ---------------- -------------- HOUSE Location/Comments ----------------------' ------------ HOUSE 1 Wall 212 0.065 17.8 180 90 Yes W.19.2X6.16 Front Wall 2 Wall 309 0.064 17.8 180. 90 No W.19.2X6.16G Front Garage 3 Wall 1132 0.065 17.8 27.0 90 Yes W.19.2X6.16 Left Wall 4 Wall 383 0.065 17.8 0 90 Yes W.19.2X6.16 Back Wall 5 Wall 1113 0:065 17.8 90 90 Yes W.19.2X6.16 Right Wall 6 Wall 105 0.064 17.8 90 90 No W.19.2X6.16G Right Garage 7 Roof 3379 0.025 38 180 22 Yes R.'38.2X4.24T Attic 8 Door 32 0.330 0 180 90 Yes None Solid Wood 9 Door 21 0.330 0 180. 90 No None Solid Wood PERIMETER LOSSES Length F2 Insul Solar Surface (ft) ------ Factor -------- R-val ------- Gains ----- Location/Comments ----------------------' ------------ HOUSE 10 SlabEdge 308 0.760 R-0 No To Outside 11 SlabEdge 40 0.510 R-0 No To Garaqe FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) ----- factor ----- SHGC Azm ----- --- Tilt ---- Type -------- Location/Comments ------------------------ ------------------ HOUSE 1 Wind Front (S) 30.0 0.350 0.320 180 90 Standard Vinyl Low -E Operable 2 Wind Front (S) 9.6 0.350 0.320 180 90 Standard Vinyl Low -E Fixed 3 Wind Front (S) 16.0 0.350 0.320 180 90 Standard Vinyl Low -E Fixed 4 Wind Front (S) 16.0 0.350 0.320 180 90 Standard Vinyl Low -E Fixed 5 Door Front (S) 28.0 0.400 0.320 180 90 Standard Vinyl Low -E French Door 6 Door Front (S) 28.0 0.400 0.320 180 90 Standard Vinyl Low -E French Door 7 Wind Left (W) 20.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed 8 Wind Left (W) 35.0 0.350 0.320.270 90 Standard Vinyl Low -E Fixed 9 Wind Left (W) 4.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed COMPUTER METHOD SUMMARY Page 11 C -2R Project Title.......... 3379 [/] SFD Date..08/06/03 14:48:36 MICROPAS6 v6.01 File -0731031 Wth-CTZ15S92 Program -FORM C -2R I User#-MP0553 User-Enercalc Run -Job # 073103-1 1 ------------------------------------------------------------------------------- FENESTRATION SURFACES Exterior Area U- Act Shade Orientation ------------------ (sf) ----- factor SHGC ----- ----- Azm --- Tilt ---- Type Location/Comments 10 Wind Left (W) 4.0 0.350 0.320 270 90 -------- Standard ------------------------ Vinyl Low -E Fixed 11 Wind Left (W) 4.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed 12 Wind Left (W) 4.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed 13 Wind Left (W) 4.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed 14 Door Left (W) 21.0 0.400 0.320 270 90 Standard Vinyl Low -E French Door 15 Wind Left (W) 5.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed 16 Wind Left (W) 4.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed 17 Wind Left (W) 4.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed 18 Wind Left (W) 4.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed 19 Wind Left (W) 4.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed 20 Door Left (W) 21.0 0.400 0.320 270 90 Standard Vinyl Low -E French Door 21 Door Left (W) 21.0 0.400 0.320 270 90 Standard Vinyl Low -E French Door 22 Wind Left (W) 18.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed 23 Wind Left (W) 4.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed 24 Wind Left (W) 4.0 0.350 0.320 270 90 Standard Vinyl Low -E Fixed 25 Wind Left (W) 4.0 0.350 0.320270 90 Standard Vinyl Low -E Fixed 26 Wind Left (W) 4.0 0.3350 0.320 270 90 Standard Vinyl Low -E Fixed 27 Door Back (N) 115.0 0.-70 0.320 0 90 Standard Vinyl Low -E Patio Door 28 Wind Back (N) 20.0 0.350 0.320 0 90 Standard Vinyl Low -E Fixed 29 Door Back (N) 140.0 0.370 0.320 0 90 Standard Vinyl Low -E Patio Door 30 Wind Back (N) 35.0 0.350 0.320 0 90 Standard Vinyl Low -E Fixed 31 Door Back (N) 140.0 0.370 0.320 0 90 Standard Vinyl Low -E Patio Door 32 Door Back (N) 21.0 0.400 0.320 0 90 Standard Vinyl Low -E French Door 33 Wind Right (E) 4.0 0.350 0.320 90 90 Standard Vinyl Low -E Fixed 34 Wind Right (E) 4.0 0.350 0.320 90 90 Standard Vinyl Low -E Fixed 35 Wind Right (E) 4.0 0.350 0.320 90 90 Standard Vinyl Low -E Fixed 36 Wind Right (E) 4.0 0.350 0.320 90 90 Standard Vinyl Low -E Fixed 37 Wind Right (E) 4.0 0.350 0.320 90 90 Standard Vinyl Low -E Fixed 38 Wind Right (E) 35.0 0.870 1.000 90 90 Standard Glass/Acrylic Block 39 Wind Right (E) 4.0 0.3.0 0.320 90 90 Standard Vinyl Low -E Fixed 40 Wind Right (E) 25.0 0:3.0 0.320 90 90 Standard Vinyl Low -E Operable 41 Wind Right (E) 5.0 0.3:0 0.320 90 90 Standard Vinyl Low -E Fixed 42 Wind Right (E) 4.0 0.350 0.320 90 90 Standard Vinyl Low -E Fixed 43 Wind Right (E) 9.0 0.350 0.320 90 90 Standard Vinyl Low -E Operable 44 Wind Right (E) 5.0 0.350 0.320 90 90 Standard Vinyl Low -E Operable 45 Door Right (E) 35.0 0.370 0.320 90 90 Standard Vinyl Low -E Patio Door 46 Wind Right (E) 5.0 0.350 0.320 90 90 Standard Vinyl Low -E Operable 47 Door Right (E) 21.0 0.400 0.320 90 90 Standard Vinyl Low -E French Door 48 Door Right (E) 21.0 0.400 0.320 90 90 Standard Vinyl Low -E French Door 49 Wind Right (E) 18.0 0.350 0.320 90 90 Standard Vinyl Low -E Fixed COMPUTER METHOD SUMMARY Page 12 C -2R Project Title.......... 3379 [/] SFD Date..08/06/03 14:48:36 MICROPAS6 v6.01 File=0731031 Wth-CTZ15S92 Program -FORM C -2R User#-MP0553 User=Enercalc Run -Job # 073103-1 I --=---------------------------------------------------------------------------- OVERHANGS AND SIDE FINS ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface- ----------- (sf) ----- Wdth ----- Hgth ----- Dpth ---- Hght ---- Ext ---- Ext ---- Ext ---- Dpth ---- Hght ---- Ext ---- Dpth ---- Hght ---- HOUSE 1 Window 30.0 n/a 5.0 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 9.6 n/a 1.6 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 16.0 n/a 10.0 6.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window 16.0 n/a 10.0 6.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 5.Door 28.0 n/a 7.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 6 Door 28.0 n/a 7.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 20.0 n/a 7.0 10.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 35.0 n/a 7.0 18.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 4.0 n/a 2.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 10 Window 4.0 n/a 2.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 4.0 n/a 2.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 4.0 n/a 2.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 4.0 n/a 2..0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 14 Door 21.0 n/a 7.0 1.0 5.0 n/a n/a n/a n/a n/a n/a n/a n/a 15 Window 5.0 n/a 1.6 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 16 Window 4.0 n/a 2.0 1.0 4.0 n/a n/a n/a n/a n/a n/a n/a n/a 17 Window 4.0 n/a 2.0 1.0 4.0 n/a n/a n/a n/a n/a n/a n/a n/a 18 Window 4.0 n/a 2.0 1.0 4.0 n/a .n/a n/a n/a n/a n/a n/a n/a 19 Window 4.0 n/a 2.0 1.0 4.0 n/a n/a n/a n/a n/a n/a n/a n/a 20 Door 21.0 n/a 7.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 21 Door 21.0 n/a 7.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 22 Window 18.0 n/a 3,.0 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 23 Window 4.0 n/a 7.0 18.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 24 Window 4.0 n/a 7.'0 18.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 25 Window 4.0 n/a 7.0 18.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 26 Window 4.0 n/a 7.0 18.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 27 Door 115.0 n/a 10.8 8.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 28 Window 20.0 n/a 7.0 8.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 29 Door 140.0 n/a 10.0 11.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 30 Window 35.0 n/a 7.0 11.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 31 Door 140.0 n/a 10.0 18.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 32 Door 21.0 n/a 7.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 33 Window 4.0 n/a 2.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 34 Window 4.0 n/a 2.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 35 Window 4.0 n/a 2.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 36 Window 4.0 n/a 2.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 37 Window 4.0 n/a 2.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 38 Window 35.0 n/a 7.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 39 Window 4.0 n/a 2.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 40 Window 25.0 n/a 5.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 41 Window 5.0 n/a 1.0 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 42 Window 4.0 n/a . 2.0 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 43 Window 9.0 n/a 3.0 1.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 13 C -2R Project Title.......... 3379 [/] SFD Date..08/06/03 14:48:36':;.. MICROPAS6 v6.01 File -0731031 Wth-CTZ15S92 Program -FORM C -2R I User#-MP0553 User-Enercalc Run -Job # 073103-1 ------------------------------------------------------------------------------- OVERHANGS AND SIDE FINS --- Window -- ------Overhang----- ---Left Fin--- ---Right Fin -- SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ HOUSE Standard Slab 3379 HVAC SYSTEMS Area Tested ACCA Left Rght Charge and Duct Duct Duct Manual Duct Type ------------- Surface ----------- (sf) ----- Wdth ----- Hgth ----- Dpth ---- Hght ---- Ext ---- Ext ---- Ext ---- Dpth ---- Hght ---- Ext ---- Dpth ---- Hght ---- 44 Window 5.0 n/a 1.6 1.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 45 Door 35.0 n/a 7.0 1.0 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 46 Window 5.0 n/a 1.G 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 47 Door 21.0 n/a 7.0 1.0 4.0 n/a n/a n/a n/a n/a n/a n/a n/a 48 Door 21.0 n/a 7.0 1.0 4.0 n/a n/a n/a n/a n/a n/a n/a n/a 49 Window 18.0 n/a 3.0 1.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ HOUSE Standard Slab 3379 HVAC SYSTEMS DUCT TESTING DETAILS -------------------- Duct Measured Supply Leakage Target Duct Surface Area Equipment Type (% fan CFM/CFM25) (ft2) ------------------------------------------ ----------------- HOUSE Furnace / ACSplitTXV 6% / 141.9 n/a WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ------------ ----------- ------------------- -------------- ------ ---------- Water Heater to meet minimun CEC Standards Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type ------------- Efficiency ----------- Airflow Location ------- R -value Leakage D Eff HOUSE ------------- ------- --------- -------- ---- Furnace 0.800 AFUE n/a Attic R-4.2 Yes No 0.815 ACSplitTXV 12.00 SEER Yes Attic R-4.2 Yes No 0.703 DUCT TESTING DETAILS -------------------- Duct Measured Supply Leakage Target Duct Surface Area Equipment Type (% fan CFM/CFM25) (ft2) ------------------------------------------ ----------------- HOUSE Furnace / ACSplitTXV 6% / 141.9 n/a WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ------------ ----------- ------------------- -------------- ------ ---------- Water Heater to meet minimun CEC Standards COMPUTER METHOD SUMMARY Page 14 C -2R Project Title.......... 3379 [/].SFD Date..08/06/03 14:48:36 MICROPAS6 v6.01 File -0731031 Wth-CTZ15S92 Program -FORM C -2R I User#-MP0553 User-Enercalc Run -Job # 073103-1 I ------------------------------------------------------------------------------- SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be'documented on the plans, *** ** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. **'* This building incorporates Tested Duct Leakage. This building incorporates either, Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). HERS REQUIRED VERIFICATION -------------------------- ** Items in this section require field testing and/or *** ** verification by a certified home energy rater under *** ** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF -6R installation certificate. *** This building incorporates Tested Duct Leakage. Target CFM leakage values measured at 25 pascals are shown in DUCT TESTING DETAILS above or may be calculated as documented on the CF -6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary for Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system('s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS Kitchen, baths, laundry & utility rooms shall have at least one luminaire with lamps of 40 lumens per watt or greater. ****** All fenstration products shall have a temporary label, not to be removed before final inspection, listing the certified U -Factor, SHGC, and certifying that the air infiltration requirements are met; or'have a permanent label listing, the U -Factor, certification organization, and rating procedures, or a label to allow tracking back to the original certification information on file with the certifying organization. All fenstrations units shall meet or exceed the U -Factors and SHGC's listing on the CF -1R Form. ****** Plan is-54-294 Shoal Creek Road La Quinta, CA APN:775-060-008-7' HVAG- --S I Z ING - -- - Page 16 HVAC Project Title.......... 3379 [/] SFD Date..08/06/03 14:48:36 Project Address........ La Quinta Plan 1 ******* --------------------- Victor Valley, CA *v6.01* I Documentation Author... Judith B. Nelson, CEPE ******* I Building Permit # En=rcalc I I 1998 Lindsay St Plan Check / Date I Hesperia, CA 92345 I I No I Field Check/ Date I Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-0731031 Wth-CTZ15S92 Program-HVAC SIZING I User#-MP0553 User-Enercalc Run-Job # 073103-1 ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- FloorArea .................. Volume.... ................. Front Orientation.......... Sizing Location............ Latitude ................... Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange ............... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 3379 sf 40716 cf Front Facing 180 deg (S) RIVERSIDE EXP STATION 34 degrees 34 F 70 F 102 F 78 F 36 F No No No 0.20 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btuh) (Btuh) ------------------------------------------------------- Opaque Conduction and Solar...... 20462 8517 Glazing Conduction ............... 13875 9250 Glazing Solar .................... n/a 17469 Infiltration ..................... 19894 8460 Internal Gain.... ................ n/a 2100 Ducts ............................ 5423 4580 Sensible Load .................... 59653 50376 Latent Load ...................... n/a 10075 ----------- Minimum Total Load 59653 ----------- 60451 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment.