07-2230 (AR),^
P.O. BOX 1504 �.
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT
- BUILDING PERMIT
Application Number: 67-00002230 Owner:
Property Address: 54339 SHOAL CREEK KEN SIVE
APN: 775-061-056- - - 54339 SHOAL CREEK
Application description: ADDITION - RESIDENTIAL LA QUINTA, CA 92253
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 5033
Contractor:
Applicant: Architect or Engineer: 7C' S CONSTRUCTION & MAINT
48236 VISTA DE NOPAL
LA,QUINTA, CA 92253
(760) 564-5811
Lic. No.: 594043
I hereby affirm under penalty of perjury
Section 7000) of Division 3 of the Busi
License Class: B1
Datet P(!_ff _Qntractor:
CONTRACTOR'S DECLARATION
nsed under provisions of Chapter 9 (commencing with
es pals Code, and my License is in full force and effect.
License No.: 594043
/,,OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perj y that I m exempt from the Contractor's State License Law for the
following reason ISec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to itsissuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
( 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
( ) I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued ISec. 3097, Civ. C.I.
Lender's Name:
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS. (760) 777-7153
Date: 12/28/07
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy er are:
Carrier STATE FUND olicyNumber 0038731-2007
_ I certify that,�inthe perfor nce of he work far which this permit is issued, I shall not employ any
person in anners as to ecome subj to the workers' compensation laws of California,
and agreef I sh Id be me s bject o t e workers' compensation provisions of Section
��FAILIURE
3700 of tor C de, all f r wit comply with those provisions.
'Dateplicant:WARNISECUR WO KERS' C MPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TOC MINAL TIES AND CIVIL FINES UP TO ONE HUNDRED' THOUSAND
DOLLARS ($100,0001. IN ADD ION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR'IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the .
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the a ve infor atioaisrrect. I agree to comply with all
city and county ordinances and state laws relating to buildi constr do , authorize representatives
offth county to enntter upon t above-mentioned propert for in ctio p
Dated)-dfS' ature (Applicant or Agent):
LQPERMIT r
Application Number .
. 07-00002230
a ------ •.Structure Information
88SF MISC. ADDITION/V-NR/RES-3
[CONV.] -----
Other struct info
CODE EDITION
2001/2005
# BEDROOMS
.00
FLOOD ZONE
NO
1ST FLOOR SQUARE FOOTAGE
88.00
Permit . . .
BUILDING PERMIT
Additional desc .
Permit Fee . . .
81.00 Plan Check Fee
52.65
Issue Date . . . .
Valuation
5033
Expiration Date
2/16/06
Qty Unit Charge
Per
Extension
BASE FEE
45.00
4.00 9.0000
THOU BLDG 2,001-25,000
36.00
.Permit . . .
ELECT - ADD/ALT/REM
Additional desc
Permit Fee . .
18.08 Plan Check Fee
4.52
Issue Date . . . .
Valuation . .
. . 0
Expiration Date
2/16/08
Qty Unit Charge
Per
Extension
BASE FEE
15.00'
88.00 .0350
-----------------------=----------------------------------------------------
ELEC NEW RES - 1 OR 2 FAMILY 3.08
Permit . . .
MECHANICAL
Additional desc .
Permit Fee . .
33.00 Plan Check Fee
8.25
Issue Date . . . .
Valuation . .
. . 0
Expiration Date
2/16/08
Qty Unit Charge
Per'
Extension
BASE FEE
15.00
1.00 9.0000
EA MECH FURNACE <=100K
9.00.
1.00 9.0000
EA MECH B/C <=3HP/100K BTU -
9.00
Permit . . .
PLUMBING
Additional desc .
Permit Fee . . . .
36.00 Plan Check Fee
9.00
Issue Date . . . .
Valuation . .
. . 0
Expiration Date
2/16/08
Qty Unit Charge
Per
Extension
LQPERMIT r
LQPERM[T
Application Number 07-00002230
Permit . . . . . . PLUMBING
Qty Unit Charge` Per
Extension
BASE FEE
15.00
2.00 6.0000 EA PLB FIXTURE
12.00
1:00 6.0000 EA PLB ROOF DRAIN
6.00
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
----------------------------------------------------------------------------
Special Notes and Comments
" 88SF MISC. ROOM ADDITION/V-NR/RES-3
[CONVENTIONAL]'PROPOSED ADDITION IS NOT
APPROVED FOR SLEEPING ROOM. THIS PERMIT
DOES NOT INCLUDE BLOCK WALLS. 2001 CBC,
-CPC, 2004 CEC, 2005 ENERGY. August 20,
-
2007 12:51:56 PM AORTEGA
-------------------------------------------------------=--------------------
Other Fees . . . . . . . . . ENERGY REVIEW FEE
5.27
STRONG MOTION (SMI)
- RES
.50
Fee summary Charged Paid Credited
Due
Permit Fee Total 168.08 .00
.00
168.08
Plan Check Total 74.42 .00
.00
74.42
Other Fee -Total 5.77 .00
.00
5.77
Grand Total 248.27 .00
.00
-248..27
LQPERM[T
Bin # -
A
'
City of "La Quinta.
Building u Safety Division -
P.O. Box 1504, 78-495 Calle Tampico
U Quinta, CA 92253 - (760) 777-7012 `
Building Permit Application and Trackin g Sheet
t
Permit.#
Project Address: 33 [ 5WcL. Cle_
Owner's Name: 'S1 J�
A. P. Number: �'� 5 + j�6 • •?�
Address: 54 3 3 itita�r L
�1�
Legal Description: �./ i TA 3*7ei.
City, ST, Zip:�i ju� � l L•Z C.
Contractor: "�� �� • ,
Address: S
Telephone:
Project Description:
City, ST, Zip:
60,,u, 1 Z`I4 .
Telephone:
State Lic. # : City Lic. #:
Arch., Engr., Designer: 1C-#j,%TD
1
Address: - �•X
City, ST, Zip:, V •
. .
,J J
Telephone: • 1496 o
State Lic. #:
Name of Contact Person:
Construction Type: Occupancy:
Project type (circle one): New 'Ad& Alter Repair Demo .
Sq. FL:
# Sto 'es:
# Units:
Telephone # of Contact Person:
Estimated Value of Project: Z4 a�
APPLICANT: DO NOT WRITE BELOW THIS UNE j
#
Submittal
Req'd
Rec'd
TRACKING . PERMIT FEES
Plan Sets
01
Plan Check submitted NO Item
Amount
Structural Calcs.
Reviewed, ready for corrections Plan Check Deposit
Truss Calcs.
o�
Called Contact Person Plan Check Balance
Energy Calcs..
Plans picked up Construction
Flood plain plan
Plans resubmitted Mechanical
Grading.plau
2" Review, ready for correctionsllssue Electrical
Subcontactor List
Called Contact Person Plumbing
Grant Deed
Plans picked up S.M.I.
H.O.A. Approval
Plans resubmitted Grading
IN HOUSE:
M Review, ready for correctionsrssue Developer Impact Fee
Planning Approval
Called Contact Person A.I.P.P.
Pub. Wks. Appr ."
Date of permit issue
School Fees
-- —
--
'
---- -------... _.....
V
Total Permit Fees
wvf�d%09 JIM it "jn16.:er..a&
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road ¢ BERMUDA DUNES O
Cn RANCHO MIRAGE d
Date 12/26/07 La Quinta, CA 92253 INDIAN WELLS
PALM LA QUINTA y
No. 29830 (760) 7714515 �'
�PINDIO S^4;
O .vJ
Owner Ken Sive APN # 775-061-056
Address 54339 shoal Creek Jurisdiction La Quinta
City La Quinta Zip 92253 Permit #
Tract # Study Area
Type Residential Addition No. of Units 1
Lot # No. Street
Unit 1 54339 Shoal Creek
Unit 2
Unit 3
Unit 4
Unit 5
Comments
S.F.
88 Unit 6
Unit 7
Unit 8
Unit 9
Unit 10
Lot # No. Street S.F.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X" 88 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Larry Coia Check No.
Name on the check Telephone 831.5212
Funding Exempt
By Dr. Sharon P. McGehee
Superintendent
Fee collected lexemprted byO ilvrey Payment Recd 0:00 Y
Signature'',
NOTICE: Pursuant to Government Code Section 66020( (1), thi will serve to notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above will begin to run from the n which the building or installation permit for this project is issued, or from the date on which.
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original - Building Department/Applicant Copy'- Applicant/Receipt Copy - Accounting
TITLE 24 REPORT
Title 24 Report for:
SIVE CASITA
54339 Shoal Creek
La Quinta, CA 92253
Project Designer:
LENCH DESIGN STUDIO INC
P O BOX 450
LA QUINTA, CA 92247-0450
760/564-1866
Report Prepared By:
. VERNA LENCH
Lench Design Studio, Inc.
P.O. Box 450
La Quinta, CA 92247-0450
(760) 564-1866
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE��Y Job Number:
VL -1428
Date:,
AUG 0 3 2007
�a
8/1/2007
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.3 by EnergySoft Job Number: VL -1428 User Number: 5454
I„ TABLE OF CONTENTS'
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
Form WS -5R Residential Kitchen Lighting
HVAC System Heating and Cooling Loads Summary
Room Load Summary
Room Heating Peak Loads
Room Cooling Peak. Loads
1
2
3
7
9
10
11
12
13
I EnergyPro 4.3 by EnergySoft Job Number: VL -1428 User Number: 5454
Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R
,;IVF CAS TA
8/112007
Project Title
Date
59339 Shoal Creek
I a_Qtnta
Project Address
Building Permit #
Lench DP.i_Seo,
Inc-
(760) 564-1866
Oa_n
Documentation thor
Telephone
plan Check/Date
Fne avPrn
15
Field Check/Date
Compliance Method
Climate Zone
TDV
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
2.29
0.87
1.42
Space Cooling
207.75
191.94
15.81
Fans
30.55
32.15
-1.60
Domestic Hot water
277.11
277.11
0.00
Pumps
6.13
6.13
0.00
Totals
523.83
508.19
15.63
Percent better
Building Type: [R] Single Family
❑ Multi Family
Building Front Orientation:
Fuel Type:
Fenestration:
❑ Addition
❑ Existing + Add/Alt
(N) 0 deg
Natural Gas
Area: 24 ft2 Avg. U: 0.37
Ratio: 26.9% Avg. SHGC: 0.32
1,
Total Conditioned Floor Area
Existing Floor Area:
Raised Floor Area:
Slab on Grade Area:
Average Ceiling Height:
Number of Dwelling Units:
Number of Stories:
BUILDING ZONE INFORMATION # of Thermostat
Zone Name Floor Area Volume Units Zone Type Type
HVAC 8 74R 1 nn Condifioned SPtbaCk—
OPAQUE SURFACES Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt
Rnof Wnnd 88 n nes R-18 R -n n n n
Wall Wnod A5 n 1n2 R-11 R_n n n gn
noor None 17 0 50[1 Nnne R -0.O 0 90
Will Wnnd 55 n 074 R_13 R_4 5 97n g_n
Wall Wnnd 1n2 n_n7a R_13 R-4.5 1A0 An
Will Wnod 46 n.n74 R-13 R_4-5 go go
88 ft2
n/a ft2
0 ft2
88 ft2
8.5 ft
1.00
1
Vent
Hgt. Area
2 n/a
Gains Condition
Y / N Status JA IV Reference Location / Comments
1 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1428 Page:3 of 13 1
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
SIVE CASITA 8/1/2007
Project Titie Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazina Tvoe Comments
-I— Window Right () 7.0 0.370 NFRC 0 32 NFRC 270 _9Q_ New IWC 5300 Vinyllow-F ZONE 1
2 Window Left (E) 16.7 0.370 NFRC 0_32 NFRC 90 90 New IWC 5300 VinWLow-E ZONE 1
1. Indicate source either from NFRC or Table 116A.
2. Indicate source either from NFRC or Table 11613.
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin
# Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA. Dist. Len. Hgt. Dist. Len. Hgt.
1 Bug Screen 0.76
2 Buo Screen 0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES
Insulation
Condition
Location/
Type Length
R -Val. Location JA IV Reference
Status
Comments
Slab Perimeter 12
None No Insulation 26-A1
New
ZONE 1
Slab Perimeter 27
None No Insulation 26-A1
New
ZONE 1
Run Initiation Time: 08/01/07 10:10:30 Run Code: 1185988230
EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1428 Page:4 of 13
Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R
SIVE CASITA 8/1/2007
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum Condition Thermostat
Location Type Eff Type Eff Status Type
HVAC Split Heat Pump 10.00 HSPF Split Heat Pump 19.0 SEER New Setback
HVAC DISTRIBUTION
Location
Duct Duct Condition Ducts
Heating Cooling Location R -Value Status Tested?
Ducted Ducted Attic 4.2 New Yes
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS Rated
Tank
Energy
Tank Insul.
Water Heater # in Input
Cap.
Condition Factor
Standby
R -Value
System Name Type Distribution Syst. (Btu/hr)
(gal)
Status or RE
Loss (%)
Ext.
EEMAX•EX190T Large Elec. Recirc/Time+Temp 1 50,000
0
Existing 0.83
4.00%
0.0
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or w/C(Documentation Author
Name: Vfessions Code)
Name: VERNA LENCH
Title/Firm: ENCH GaIGN STUDIO INC Title/Firm: Lench Design Studio, Inc.
Address: P O 3W450 Address: P.O. Box 450
LA Q IN CA 92247-0450 La Quinta CA 92247-0450
Telephone: 760 64 866 Lic el p one: 760 6 866
l
(signature)7 (date) signature) (date)
Enfo cement Agency
N e:
e/Firm:
Address: STAMP
Telephone:
(signature) (date)
Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R
SIVE CASITA 8/1/2007
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local enforcement
agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the
adequacy oT the speaai /ustiticauon ana documentation suomitted.
Plan I Field
IThe Roof "R-38 Roof Attic" includes credit for a Radiant Barrier installed Der Section 3.3.3 of the Residential Manual. I I I
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC-
approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF4R Plan Field
installation certificate.
The HVAC System "HVAC' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R.
The HVAC System "HVAC' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve.
EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1428 Page:6 of 13 1
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the
permit application documentation.
N/A
DESIGNER
ENFORCE -
MENT
Building Envelope Measures
❑
Q
❑
*§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
❑X
❑
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
❑
❑X
❑
�§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑X
❑
apply to exterior mass walls).
❑
0
❑
+§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
❑
Q
❑
1. Masonry and factory -built fireplaces have:
❑
Q
❑
a. closable metal or glass door covering the entire opening of the firebox
❑
a
❑
b. outside air intake with damper and control, flue damper and control
❑
Q
❑
2. No continuous burning gas pilot lights allowed.
❑
0
❑
§ 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual.
❑
❑
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑X
❑
permeance rate no greater than 2.0 perm/inch.
❑
❑X
❑
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include
❑
❑X
❑
CF -6R Form:
❑
❑X
❑
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
❑X
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
infiltration
❑
❑X
❑
Coefficient (SHGC), and certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑
❑X
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑X
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑
Q
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
Q
❑
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
❑
Q
❑
having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
Q
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
❑X
❑
length of recirculating sections of hot water pipes shall be insulated to Table 1508.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑
❑X
❑
indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
❑
❑X
❑
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑X
❑
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑X
❑
EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1428
Page:7 of 13
Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -
applicable. N/A DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑
605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than
❑
❑X
❑
sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause
reductions in the cross-sectional area of the ducts.
❑
®
❑
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
❑
®
❑
duct tapes unless such tape is used in combination with mastic and draw bands.
❑
X❑
❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑
®
❑
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
❑
®
❑
dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑
®
❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
7. Flexible ducts cannot have porous inner cores. ❑
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑
❑X
❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
❑
®
❑
b. Cover for outdoor pools or outdoor spas.
❑
❑X
❑
3. Pool system has directional inlets and a circulation pump time switch.
❑
X❑
❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑
®
❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (i): Cool Roof material meets specified criteria
❑
❑
❑
Lighting Measures
§ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑
®
❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are
electric and have an output frequency no less than 20 kHz.
§ 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑
Q
❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑
❑X
❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑
❑X
❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are
❑
❑X
❑
controlled by an occupant sensor that complies with Section 1`19(d) that does not turn on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑
❑X
❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑
❑X
❑
same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑
❑
❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑
❑
❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section
119(d).
EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1428
Page:8 of 13
Residential Kitchen Lighting Worksheet WS -5R
SIVE CASITA 8/1/2007
Project Title Date
At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires
as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately.
Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens.
High Efficacy
Luminaire Type High Efficacy? Watts Quantity Watts Other Watts
.Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Total A: 0 B: 0
COMPLIES IF A,—> B YES ® NO ❑
EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1428 Page:9 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME
DATE
SIVE CASITA
8/1/2007
SYSTEM NAME
FLOOR AREA
HVAC
88
Number of Systems
1
Heating System
Output per System
21,600
Total Output (Btuh)
21,600
Output (Btuh/sgft)
245.5
Cooling System
Output per System
18,000
Total Output (Btuh)
18,000
Total Output (Tons)
1.5
Total Output (Btuh/sqft)
204.5
Total Output (sgft/Ton)
58.7
Air System
CFM per System
855
Airflow (cfm)
855
Airflow (cfm/sqft)
9.72
Airflow (cfm/Ton)
570.0
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
26.0 OF
0
Outs
0 cfm
69.7 of
69.7 of
Supply Fan
855 cfm
Return Fan
69.7 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
Sensible
255
4,584
88
227
3,443
0
475
263
0
0
0
0
0
0
0
0
0
475
263
5 534 88 3 969
FUJITSU 18RC 16,332 0 13,491
Total Adjusted System Output 16,332 0 13,491
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK F-Aug2 pm Jan 12 am
tream Temperatures at Time of Heating Peak)
84.5 OF
Supply Air Ducts
OF
RO
Heating Coil 84 2 OMS
70.0 of
69.7 of
412 cfm
h Return Air Ducts `S
of Coolina Peak
111.0 177.6 of 78,5165,90F 78.5 / 66.0 of 60.6 / 59.5 of
0
Outside Air Supply Air Ducts
0 cfm Supply Fan Cooling Coil 61.1 / 59.7 of
855 cfm 52.6% R.H. ROOMS
78.5165.9 of Return Fan 78.5 / 65.9 of 78.0165.7 OF
Return Air Ducts
412 cfm
EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1428 Page:10 of 13
ROOM LOAD SUMMARY
PROJECT NAME
DATE
SIVE CASITA
8/1/2007
SYSTEM NAME
FLOOR AREA
HVAC
88
ROOM LOAD SUMMARY '
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
ZONE 1
ZONE 1
1
255
4,584
881
255
4,584
881
227
3,443
PAGE TOTAL 1 255 4,584 881 227 3,443
TOTAL 1 255 4,584 881 227 3,443
EnergyPro By EnergySoft User Number: User Job Number: VL -1428 Page: 11 of 13
ROOM HEATING PEAK LOADS
Project Title Date
SIVE CASITA 8/1/2007
Room Information Desi n Conditions
Room Name ZONE 1 Time of Peak Jan 12 am
Floor Area 88 Outdoor Dry Bulb Temperature 26°F
Indoor Dry Bulb Temperature 70°F
Conduction Area U -Value QT of Btu/hr
Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 3 140
Infiltration: 1.00 x 1.0641 x 88 x 8.50 x 0.520 / 60] x 44 = 303
-Schedule Air Sensible Area Ceiling Height ACH LT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 3,443
EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1428 Page: 12 of 13
88.0
X
X
X
X
X
x
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0.0250
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
44
=
=
=
=
=
=
=
=
=
=
=
=
97
perimeter = 12.0
0.7300
44
385
perimeter = 26.7
0.7300
44
858
85.3
0.1020
44
383
16.7
0.5000
44
367
55.3
0.0743
44
181
7.0
0.3700
44
114
102.0
0.0743
44
334
0,0743
44
149
16.7
0.3700
44
272
Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 3 140
Infiltration: 1.00 x 1.0641 x 88 x 8.50 x 0.520 / 60] x 44 = 303
-Schedule Air Sensible Area Ceiling Height ACH LT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 3,443
EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1428 Page: 12 of 13
4
PIESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Title Date
SIVE CASITA 8/1/2007
Room Information Desi n Conditions
Room Name: ZONE 1 Outdoor Dry Bulb Temperature: 1120F
Floor Area: 88 sf Outdoor Web Bulb Temperature: 78oF
Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F
ue surraces
13 Wall
R-13 Wall w/1" EPS Interior
R-13 Wall w/1" EPS Interior
R-13 Wall w/1" EPS Interior
Orientation Area
N
88.0
N
85.3
N
16.7
W
55.3
S
102.0
E
45.6
x
0.0743
X
x
0.0743
X
x
19.3+
x
x
639
x
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
U -Factor
x
0.0173
X
x
0.1020
X
x
0.5000
X
x
0.0743
X
x
0.0743
X
x
0.0743
X
x
19.3+
x
x
639
x
x
x
X
x
X
X
x
x
CLTD 1 Btu/hr
56.0
=
=
=
=
=
=
85
23.0
200
23.0
192
33.0
136
26.0
197
33.01
112
Page Total 1 922
Orientation
Shaded
Area
x
x
x
X
x
x
x
X
x
x
GLF
+
+
+
+
+
+
+
+
+
+
Unshaded
Area
X
x
x
x
x
X
x
x
x
X
Page
GLF
=
=
Btu/hr
W
0.0
19.3
7.0
38.3
268
E
0.0x
19.3+
16.7X
38.3=
639
Total
907
Internal Gain Btu/hr
Occu ants 4 x Occupants x 230 Btuh/occ. = 920
E ui ment 1 x Dwelling Units x 1,6001 Watts/sqft = 1,6001
Infiltration: 1.064 X 1.16 x 5.58 x = 235
Air Sensible CFM ELA �T
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 4,584
Latent Gain _ Btu/hr
Occu ants x Occupants x 200 Btuh/oCC. = 800
Infiltration: 4 771 x 1.16 x 5.58 x 0.00263 = 81
Air Latent CFM ELA QW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 881
EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1428 Pa e:13 of 13