Loading...
0310-335 (SFD)ij LICENSED CONTRACTOR DECLARATION 1,I hereby affirF' un w penalty of perjury that I am licensed under provisions of Chapter �1(60mmencing with Section 7000).of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lia Class Exp. Date :368543 C5 luo /,. 01 ri 1/7C, �`i /cwt• �?'r,1 " � a ' 1 'L flf:16A ,•Date � Signature of Contractor. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole . compensation, will do the Work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). , ( ) I am exempt under Section B&RC. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this. permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier STMT, FrU-PID Policy No. 000164064504 (This. section need not be completed if the permit valuation is for $100.00 or less). () I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to. the -workers -compensation provisions^of-Section-3700-of-the-L-abor— Code, I shall forthwith comply with /,t�hose provisions. Date: :7 / r Applicant �'!. �' t y' 7. L, i -rs- a n.,. Warning Failure to secure Workers' Compensationcoverageis unlawful -and - shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. " IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance•of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction; and hereby authorize representatives of this City to enter upon the above-mentioned property,for inspection purposes. f Signature (Owner/Agent) 'f� U10-1) V✓1 %�1 �'f� Date -2/4110' BUILDING PERMIT PERMI#' 63a3�s3,*"s DATE 012fiJ120C VALUATION �,440W LOT 4 TRACT 270162 JOB SITE ADDRESS _T4-,-542 �.QAL (=J%.Y APN 17:1-06G 49A OWNER CONTRACTOR / DESIGNER / EN &NEER R0BKWf 816 1111 :fl'iZC,�.,,,7.6X47NR:'1' w CO. 34.342 VROAL, CRI -7 -It 83680 CIrrR S AVS!:. LfAQUINTA dA. Q2253 I.MD10 CA .92201 Q60)342-1182 CBLV 003362 USE OF PERMIT DINGLE FAIRLY DiAIR.1: I NO LOT 41ST?DJF%? MIT DOES NOT INCL UDIX BLOCK WP..1,L.Sb1P00L OR SPA.. ?09P CSC. . CUSTOM CONSTRUCTION 31051,0 OF PORCH/PATIO M.00 SLS Q.hFiAGfYCAR11'GRT 375.00 OF I F.R. m riXPK,' MW41A7r Y CONSTRUCTION FEE 101.000,4.18.000 31,1P6.00 . PLaA14 CHFZ,' : I�"te E 101-4000-439-318 $999, 171 FEE DEePOSIT 101-000-439-318 47950108 MECHANICAL FEE 101;-000-421-000 $130.50 _ EIJNt"TPJCAL, FU`9 101-000-420-000 8199.29 PLUMBING FEE 101-000-419-000 $24+4.50 S'TRCTt40 MOT:lON 137E - MID 101-000-241-000 $25.54 GRADINO FXE 101.1000---'2.3-000 $15.00 DkVFW PER IMPACT FEE: SM05.0(f PP=ISE PIAN 101-000-441-345 $100.00 ART 04 PUBU 1'IfA.C`L,S ' RESIE 270-000.445-000 $146.10 A T. ry ' IMON RON t>f P.1"CI"MC''T� $5,460.94! - .0 � :L _35 PRR-PAW x'93 -$750.00 i FEB 05 2004 CITY OF LA GUINTA FINANCE DEPT. RECEIPT DATE. BY / DATE A D INSPECT o,. INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS et Backs_ -Underground Ducts Forms & Footings Flab Grade :3//,o 7 _ Ducts Return Air Steel Combustion Air Roof Deck 6q A& Exhaust Fans O.K. to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath _ Drywall - Int. Lath Final _ Final BLOCKWALL A PROVALS POOLS - SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final I Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: Lot # No. Street IS.F. Lot* No. Street' S.F. Unit 1 4 54342 Shoal Creek 3051 Unit 6 Unit 2 Unit7 Unit 3 r Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.14 X 3,051 S.F. or $6,529.14 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CCNIB-Robert W. Smith Check No. 301947 Name on,the check Telephone 760-342-1182 Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted by Yolanda Garcia Payment Recd $6,529.14 Over/Under. Signature ° NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts p�� paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This' Document NOT VALID if Duplicated Embossed Original - Building. Department/Applicant Copy - Applicant/Receipt Copy - Accounting CERTIFICATE OF COMPLIANCE. IEO& Desert Sands Unified School District �� 47950 Dune Palms Road ¢ 9ERMUDADUNE3 r Date 2/5/04 La Quinta, CA 92253 RANCHO MIRAGE (7 �r No. 25477 (760) 771-8515 {� INDIAN WELLS DESE d� PALM u►QUINTA y INDIO O Owner Robert Smith APN # 775-060-004 Address 54-345 Shoal Creek Jurisdiction La Quinta City La Quinta Zip 92253 Permit # 0310-335 Tract # . 27762 Study Area Type. Single Family Residence No. of Units 1 Lot # No. Street IS.F. Lot* No. Street' S.F. Unit 1 4 54342 Shoal Creek 3051 Unit 6 Unit 2 Unit7 Unit 3 r Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.14 X 3,051 S.F. or $6,529.14 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CCNIB-Robert W. Smith Check No. 301947 Name on,the check Telephone 760-342-1182 Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted by Yolanda Garcia Payment Recd $6,529.14 Over/Under. Signature ° NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts p�� paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This' Document NOT VALID if Duplicated Embossed Original - Building. Department/Applicant Copy - Applicant/Receipt Copy - Accounting ClT-YlqF LA QUINTA - lOUILbiNG &-SAFE7,DEPARTMENT :z V,:! 7* -7012 INSPECTION REQUEST LINE 7�T-71153- ''URT Smil, Owl�e RA Cot tractor TIC� Pert 4310-335 IN CONSPICUOUS PLACE.' ­ 11K PE T. -;,8T SIGN ALL APPLICABLE SPACES JOB ADDRlt§S'. 54-342. SHOAL CREEK SINGLK'� AMELY DWELLING PERMIT K 'CLUDE POOL-,. SPA OR i km DOES T IN WA v T 0 TYPE OF [N*CTlOk' INSP. TEMPORARY POWERL SETBACKS :U/G PLUMBING 91 __ IJ/G ELECTRICAL/ OR WING, FOOTINGS / STEEL -2 q I,/ CONCRETE SLAB --,�'-4 DO NOT POUR Cd OVE,SIG NED, ftttF ROOF NAIL/ PRF-ROOF:.,Y OKAY TO WRAP FRAMING (COMBINATION'T�'�� ROUGH ELECTRIC.- 7 ROUGH PLUMBING;. ROUGH MECHANICAL`-, ',INSULATION COVER NO WORK'YJNTIL,41$OVE,SIGNE -INTERIOR GYP. BD. (DRYWALL) EXTERIOR LATH I "GAS TEST SEPTIC ABANDONMENT SEWER CONNECTION T. - SEPTIC / GREASE INTERCEPTORh` MASONRY INSPECTIONS FOOTINGS / STEEL BOND BEAM POOL / SPA / WATER FEATURE INSPECTIONS PRE-GUNITE / SETBACKS U/G'PLUMBING U/G ELECTRICAL PRE-PLASTIEW(ALARMS /'BARRIERS) FINAL INSPECTIONS -- TEMP. USE OF PERMANENT POWER 4 ELECTRICAL. PLUMBING MECHANICAL .,;PLJ BLI C WORKS DEPARTMENT 'COMMUNITY DEVELOPMENT. DEPT FINA(SNOBCOMPLETED . - I - 'ABOVE APPROVALS DO' NOT INCLUDE RIGHT TO TURN ON UTILITIES OR- OCCUPY BUILDING- 7 Y -airf 0 6, 7to ham: C" ettifi upanc�, ��r= 0 'lGCi ow W7 V atet 'Y r a. Y'i ,rri- - _ '� F r..*. J w � ; } �.r',k OF l3o Buil in enrDepartmtt .-TWp;;zCe&rlcat6 is_ .,i��sued,pursuant',to,,(46.re�`uir'eme fs.�ofOOefi6qn n.- 109 -;,of the `X41ifbmiaI(3qi ding , issuance f- re lianciq�-i With, th Cod6,,. certllfkmd� that; jaf-the7--fithe.,­o?. his structure` wasAP,., tbftlb ;;� - . - . Jql - , -, ' 9 2"i- , 7�:i�'-q _-, % provisions *.6f Attie .;Builjlin od6�.arid.the"-•RrJr 'llb&ildin' 9! various z,,dMifian -City.- -r.djdjafinq,y. of the.,. 91 -us coh. &Uction andl6r. e. 'dR jD NOADDRES ­54---34ru 2 `SHOALE E K -j* BUIL 8 U s'elcl6ssificafion: S NGLE'TAMILY DWELLING Buido.A310M. hg.Permit, C_ cy RrW� ype o, 7,6n�trqdfion: .N -and'We�Zone:-RL roub f W� d1ccupan Gi,­­ L di*egs�` ".7342 S -A H6kL:CkEEkl4 -6wn"er'd Buildi�-�q-'-.,ROB'r='R�-Tr'8iA!TH;' d WQUINTA,*CA-922t3; dty,ST,'ZlP ui. o ..,6AWY HARTMAN- pt, 5, 004 N 2 Sdpt6mber 2,' ttF `BUildifi kcial n ,,, o CONSPICUOUS OST4N A ONSF�l UOMPLACE, 11/14/02 City of La Quinta Department of Building & S RE: Herthel Residence Gentlemen: This letter is to state that the you have any questions, plea w 10 ohn Acosta, AIA ,icens d Architect CALIF. LICENSE #C24055 • ARIZONA 1. ARCHITECTURE ARCHITECTURE &ENGINEERING BIG BEAR CITY AIRPORT • SUITE A-1 '0. BOX 6167 • BIG BEAR LAKE, CA 92315 (909) 585-6311 ri • if tyy . Ih IJ i .,sign of the trusses are in accordance with my design intent. If do not hesitate to call. ARC,�,��� :E'' JOHN F ACOSTA, III A.I.A. N0. C24055 Rct�l. �t-3G-03 ;i 4i . h i w t , N5E #28023 • CALIF. O.E.5. KEGI5TEKED EARTHQUAKE DAMAGE A55E550R #5A1373 MOUNTAIN ARCHITECTURE ARCHITECTURE & ENGINEERING BIG BEAR CITY AIRPORT • SUITE A-1 P.O. BOY, 6167 • BIG BEAR LAKE, CA 92315 (909) 585-6311 John F. Acosta III, Architect, AIA 7/24/01 City of LaQuinta Department of Building and Safety La Quinta, CA - RE: Herthel Residence 54354 Shoal Cieek La Quinta CA Gentlen�en: i i I have checked'the revised truss layout -plan on the above -referenced-project� and find -that it conforms to the design intent of the project. - Contractor is to verify all dimensions prior to ordering the-tiuss. costa, AIA Architect CALIF. LICENSE #C24055 • ARIZONA LIICEN5E #28023 • CALIF O.E.5. KEGI5TERED EARTHQUAKE DAMAGE A55E550R #5A1373 i TNr MOUNTRIN RRCHITECTURE C!"y t.f Depa-trliep- -'Sildding and Saifcnv r i o z-efrofit rn; i :'ng aric'lo, boh.s. A-',') 7/ 0:11 3torl., eA AJA Lict iced Arch .1jr j B.G. STRUCTURAL ENGINEERING BRIAN GOTTLIEB - CIVIL ENGINEER - Lic. No. C33047 45-535 Via Cortina Indian Wells, CA. 92210 (760) 568-3553 (760) 568-5681 Fax June 1, 2004 v Mr. Kim Fincher Kim Fincher Construction 82-800 Avenue 58`h, #17' Thermal, CA 92274 RE: Smith Residence — La Quinta, CA The purpose of the site. observation work undertaken -by B.G Structural Engineering for the above named project was to confirm' that this project has been constructed in general conformance with the structural drawings and as required by the 2001 CBC Section 1702. Observation of the construction of this project was conducted or supervised by Brian Gottlieb of this office. These observations were to establish the conformance of several items including, but not limited to: conformance of framing to framing plans, the assembly of shear walls, wall sheathing, drag straps, holdowns, and detailed connections. Corrections were provided after each observation to communicate the items of concern to the builder. Subsequent re- checks of the structure for compliance were performed until all outstanding correction items were resolved. In conclusion it is the opinion of this office that the construction of this project is in general conformance with the requirements of the structural drawings. The conclusions reached above are based solely on a. visual review of the structure. Due to the visual nature of these observations, and limited access to structural elements, a general review of the structural elements, and connections has been performed. No tests have been conducted on any materials or soils and no warranties are expressed or implied. The opinion above is based upon widely held engineering principles and judgment, and it follows a standard of care which defines a level of skill and competence ordinarily and contemporaneously demonstrated by professionals of the same discipline practicing in the same locale and faced with the same or similar facts and circumstances. l JON TANDY 78-194 Elenbrook Ct. Palm Desert, CA 92211 � Office (760) 772-7192 SPEC IAL INS.PECTIONFax (760) 772-7193 Pager (760) 776-3338 REGISTERED INSPECTOR'S WEEKLY REPORT TYPE OF INSPECTION PERFORMED ❑ REINFORCED CONCRETE O ,�RUCT. STEEL ASSEMBLY O POST TENSIONED CONCRETE O ASPHALT O REINFORCED MASONRY_ ❑ FIRE PROOFING O s 1B.BTHER , �(1`Ily T` W" JOB LOCATIONS+ ^� S 4 Q e 1_ �cQ �U ` V\_ A f T REPORT SEQUENCE NO. TYPE OF STRUCTURE PA `7�� ,[� �,f� JQ F (� PERMIT NO. 1INSPECT911- DATE 3 a DAY OF WEEK 1HRS.CHARGED MATERIAL DESCRIPTION -A _ � H ARCHITECT /H� 1 ENGINEER nfGr_ ASSISTANTS HRS. CHARGED INSPECTION -DATE GENERAL SUB n :CONTRACTOR .. .I ..._. IlJC6le12 _ - ,-CONTRACTOR_ _,�'�• WC?C�1� il� �aSe-2ic oo e- IPAss CA)e4-k1_'.% It-' 8-F �!r r -k--o e -c -Z I aI Couti L G - 9 COPY SENT TO CLIENT O CONTINUED ON NEXT PAGE O PAGE OF CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS. SPECIFICATIONS. AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS. SI NATUR .OF REGISTERE INSPECTOR DAIE OF REPORT REGISTER NUMBER UUUb54 Sladden , 6782 Stanton Ave., Suite A, Suena P. . i ^062.1 (7t a) 523.0952 f Fax (714),523.1369 39.725 Garand I.P. ,Suite G, Palm Desert. CA 32211 (760).M-103' Fax (760)772-3895 Date 3-'r'— o 4 _ Job No: e v o 110 Client: Site Address Job Phone . Work Done ---- - . -- J) Q r-45 t t-,,/ 'r>C5 Y r. b c ►r: Fb D U� S G ZQIk O f That Summsty / Footings lnsptactod Test '— -. _ I T Ory Moist '„ ReleGve•j-Ref. Max Moist i Lcx ation ` Elegy. Densi °� Compactlonl pcf f7e 1 ; tVo. ......____ _— '_... .� t o • 5_ �-- �`d t I'L � • k�- �__ - --- -- - -7.0 . L1_.—. I ------------- pal S= + Wit_ -----'- ----------•--- •-c -' __—_---'-j--- --..— - - ----' • �1•,C0111nlentS '1 � .. , p r4 C — rr (D. y. 1 t � Field rech.,, ,`�c+o } `. ,r r, , `! `' t ; • ti` T %S' ' • ti6 `,�Tl .' . y.ri� 4. ,� p�� r �/ .� �4;: � �;Fk .���., ,. , per�+or gerit•w � f -^f,,."' .,. ,� }•• - :� i�. � 9n v71 fi�a'z k�i�l`e24 hour notice r6 UA5{ t6jposcule FifTech i nk•Qrtr u . i. � ityF�seiev Ce i ✓. TITLE 24 REPORT i Title 24 Report for: Bob Smith-Custom Residence Lot 4, Tract 27762, Shoal Creek La Quinta, Ca 92253 Project Designer: Prest Vucsic, Architects 72-624 EI Paseo, #B-6 Palm.Desert, Ca 92260 CITY OF L:A QUINTA (760) 779-5393 BUILDING & SAFETY DEPT. APPROVED FOR CONjBY__ ON Report Prepared By: Di�TE� �2�_0 ' Tim Scott H.& H Air Conditioning 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 i (760) 340-3088 Job Number: f Date: 1/8/04 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. M, I This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 •3'�� SNopl C fait. ���. c8L a TABLE [OF CONTENTS i Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Complj ance 3 Form MF -1 R Mandatory Measures Checklist 7 Form C -2R Computer Method Summary 9 HVAC System Heating and Cooling Loads Summary 14 Room Load Summary l 17 Room Heating Peak Loads 20 Room Cooling Peak Loads 23 L • i EnergyPro 3.1 By EnergySoft Number: r User Number: 5533 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R •Bob Smith -Custom Residence 1/8/04 Project Title a e Lot 4, Tract 27762, Shoal Creek La Qulinta vroject Aaaress H & H Air Conditioning (760) 340-3088 ocumen a ion Author I a ep one Computer Performance . 15 Building ermit Plan Check I Date Field ec Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,051 f? Average Ceiling Height: 11.0 ft Total Conditioned Slab Area: 3,051 ft2. Building Type: (check one or more) © Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (South)180 deg Floor Construction Type: FRI Slab Floor Number of Dwelling;Units: 1.00 Number of Stories: 1 ❑ Raised Floor BUILDING SHELL INSULATION Component Type Frame Type Const. Assembly U -Value Location/Comments ' (attic, garage, typical, etc.) R-38 Roof (R.38.2xl4.16) Wood .0.028 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall Slab On Grade nla 0.756 Covered Slab w/R-0.0 Perimeter insulation Slab On Grade n/a 0.756. Exposed Slab w/R-0.0 Perimeter Insulation Solid Wood Door None 0.387 Exterior Door FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Skylight6.7 0.80 0.39 None ❑ X❑ ❑ X❑ Right (East) 8.0 0.72 0.60 Bug ScreenX❑ ❑ X❑ ❑ Front (South) 42.0 0.72 0.46 Bug ScreenX❑ ❑ X❑ ❑ Left (West) 8.0 0.72 0.60 Bug Screen ❑ XD X❑ ❑ Rear (North) 100.0 0.75 0.46 Bug Screen ❑X ❑ X❑ ❑ Rear (North) 350.0 0.75 0.46 Bug Screen X❑ ❑ ❑ X❑ Front (South) 5.0 0.72 0.60 Bug Screen ❑ X❑ X❑ ❑ Front (South) 60.0 0.72 0.46 Bug Screen ❑ X❑ X❑ ❑ Front (South) 15.0 0.72 0.46 Bug Screen ❑ © ❑ Front (South) 48.0 0.99 0.39 Bug Screen ❑ XO ❑ XO Left (West) 60.0 0.72 0.46 Bug Screen ❑ X❑ X❑ ❑ Rear (North) 17.0 0.72 0.60 Bug Screen ❑X❑X❑ ❑ Run Initiation Time: 01/08/04 10:01:23 Run Code: 1073584883 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 25 • Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Bob Smith -Custom Residence 1/8/04 Project Title -D-ale Lot 4, Tract 27762, Shoal Creek La Quinta vro/ect Aaaress H & H Air Conditioning (760) 340-3088 Documentation AUthor i a ep one Computer Performance 15 Compliance Method (Package or Computer) Climate Zone GENERAL INFORMATION Total Conditioned Floor Area: 3,051 ft2 Total Conditioned Slab Area: 3,051 ft2 Building Type: (check one or more) © Single Family Detached ❑ Single Family Attached ❑ Multi -Family Building ermi Plan Check / Date iela L;neCK I Date Enforcement Agency Use Only Average Ceiling Height: 11.0 ft ❑ Addition ❑ Existing Building ❑ Existing Plus Addition Front Orientation: (South) 180 deg Floor Construction Type: X❑ Slab Floor Number of Dwelling Units: 1.00 Number of Stories: BUILDING SHELL INSULATION ❑ Raised Floor Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Right (East) 56.0 0.75 0.46 Bug Screen X❑ ❑ ❑ X❑ Right (East) 48.0 0.72 0.46 Bug Screen ❑ x❑ ❑ ❑X Left (West) 56.0 0.75 0.46 Bug Screen ❑ X❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El F1 F1 El El El F1 El El ❑❑ El El ❑ ❑ ❑ ❑ Run Initiation Time: 01/08104 10:01:23 Run Code: 1073584883 EnergyPro 3.1 By EnergySort User Number: 5533 Job Number: Page:4 of 25 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R •Bob Smith -Custom Residence 1/8/04 Project Title -D-ale HVAC SYSTEMS ' Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments • Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -1 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -2 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -3 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (.attic, etc.) R -Value Type Comments Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -1 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -2 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -3 WATER HEATING SYSTEMS Rated 1 Tank Energy Facts . 1 External Water Heater Water Neater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type . Syst. Btu/hr (gal) Efficiency Loss (%) R -Value AMERICAN G62 -100T88- Large Gas Recirc/Time+Temp 1 88,000 100 0.81 0.0244 12.0 I For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Tim Scott Title/Firm: Prest Vucsic, Architects Title/Firm: H & H Air Conditioning Address: 72-624 EI Paseo, #13-6 Address: 74-991 Joni Drive #20 Pal Desert, Ca 92260 Palm Desert, CA 92260-2043 Tel phon 760 7939 Telephone (760) 340-3088 Lic. #: 51o,4— (signature) V V (date (signature) I (date) Enforcem Hagcy Name: Title/Firm: Address: • Telephone: signature/stamp (date) Run Initiation Time: 01/08/04 10:01:23 Run Code: 1073584883 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:5 of 25 Certificate of Compliance: Residential (Addendum) CF -1 R Smith -Custom Residence 1/8/04 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C-211) - Verify Thermal Mass: 653 sqft Covered Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C-211) - Verify Thermal Mass: 140 sqft Exposed Slab Floor, 3.50" thick at Master Suite The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C-211) -Verify Thermal Mass: 118 sqft Covered Slab Floor, 3.50" thick at Kitchen/Living/Entry HIGH MASS Design(see C-211) -Verify Thermal Mass: 1133 sqft Exposed Slab Floor, 3.50" thick at Kitchen/Living/Entry The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C-211) - Verify Thermal Mass: 749 sqft Covered Slab Floor, 3.50" thick at Bedrooms 12 & 18 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 258 sqft Exposed Slab Floor, 3.50" thick at Bedrooms 12 & 18 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS PI VYIYGI. I IIV IQICI IllUaL YVI YIIIGIII 111G IIV VVI 11 IU aL VII all YI aWIIWZ0lll. l QII. IIU VI 111CJC IIICGDUICD Vll d IVII11 lir-UR. an e ld 'fhe HVAG System - includes Ketrigerant Charge and Airflow Crean (ora certMea HLRS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit or a TXV). A certified HERS rater must proved verifification of the TXV, or measure the Refrigerant Charge and Airflow. he R ys em is using reduced uc leakage to comply and must nave diagnostic site testing ot ductleakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAG System includes Refrigerant Charge and Airflow Credit (ora certitieCi HLKti rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAG System is using re ucea ductleakage to comply and must have diagnostic site testing of ductleakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. I Run InitiationTime: un Code: 1073584883 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:6 of 25 lr �, u �.J • Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on th,s checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ®'§150(a): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. *§150(c)- Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ® not apply to exterior mass walls). ❑'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. ® §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑§150(g): Vapor barriers mandatory in Climate Zones 14 and '16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. a§150(e): Installation Fireplaces, Decorative Gas Appliances Gas of and Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ® § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. a§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ®§150(i): Setback thermostat on all applicable heating and/or cooling systems. ©§1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non-recrculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:7 of 25 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk • (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • • DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) 150(m): Ducts and Fans u 1. All ducts and plenums installed, sealed and insulated to meel the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. ,Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, 61-181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot.. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria Lighting .Measures §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to.the kitchen. i� §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5533 Job Number: Page:8 of 25 Computer Method Summary (Part 1 of 3) C -2R Mob Smith -Cum Residence 1/8/04 sto oject itle # mate Lot 4, Tract 27762, Shoal Creek La Quinta Project Aaaress s Buirdmg Pe�mif H & H Air Conditioning i (760) 340-3088 -Documentation Au ofd'" { e ep one PlanC eh c dD e Computer Performancet} 15 Fie@-ChecrJDate -Compliance Meted -(Package or Computer j CIrma —on Source Energy Use Standard (kBtu/sf-yr) Design Space Heating 4.03 Space Cooling 38.44 Domestic Hot Water 9.34 Totals 51.82 Design Margin } 6.25 -2.21 35.11 3.33 10.43 -1.09 51.79 0.03 UtNtKAL INt-UKPAA i IUN 0 Slab Floor Conditioned Floor Area: 3,051 Floor Construction Type: F-]RaisedFloor Building Type: Single Fam Detached Building Front Orientation: (South) 180 deg Total Fenestration Area: 28.8% Number of Dwelling Units: 1.00 Total Conditioned Volume: 33,604 Number of Stories: 1 Slab Floor Area: 3,051 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC -1 793 I 8,723 0.26 Sleeping_ SleepingStat 2 _n/a VAC -2 1,251 115,012 0.41 Living Livin Sg tat 2 n/a epinpin2 VAC -3 1,007 1 9,869 0.33 Sleg SleegStat n/a I OPAQUE SURFACES �o Act. Gains Type Area U -Fac. Azm. Tilt Y / N I Form 3 Reference Location / Comments Computer Method Summary (Part 2 of 3) C -2R b Smith -Custom Residence 1/8/04 �dtrta Dae # Type 1 Skylight Rear ;F Window Right 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 r Window Rear (North' Window Rear (North; Window Rear (North'. Window Front (Sou(h) Window Front (South) Window Front (South) Window Front (South) Window Left (West) Window Rear (North) Window Rear (North) Window Right (East) Window Right (East) Window Right (East) Window Left (West) U_ Area Factor SHGC 6.7 8.0 42.0 8.0 100.0 200.0 150.0 5.0 30.0 15.0 30.0 48.0 60.0 6.0 11.0 56.0 24.0 24.0 56.0 0.800 0.720 0.720 0.720 0.750 0.750 0.750 0.720 0.720 0.720 0.720 0.990 0.39 0.60 0.46 0.60 0.46 0.46 0.46 0.60 0.46 0.46 0.46 0.39 0.720 0.46 0.720 0.60 0.720 0.60 0.750 0.46 0.720 0.46 0.720 0.46 Act. Glazing Type Azm. Tilt 0 90 180 270 340 0 0 180 180 180 180 180 270 0 0 90 90 90 0.750 0.46 270 0 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 Skylight Glass Block Double Metal Low a sq Glass Block Double Metal Low a sq Double Metal Low a sq Double Metal Low a sq Glass Block Double Metal Low a sq Double Metal Low a sq Double Metal Low a sq Single NonMtl Tinted Default Double Metal Low a sq Glass Block Glass Block Double Metal Low a sq Double Metal Low a sq Double Metal Low a sq Double Metal Low a sq Location/ Comments Master Suite Master Suite Master Suite Master Suite Master Suite Kitchen/Living/Entry Kitchen/Living/Entry Kitchen/Living/Entry Kitchen/Living/Entry Kitchen/Living/Entry Kitchen/Living/Entry Kitchen/Living/Entry Kitchen/Living/Entry Bedrooms 12 &18 Bedrooms 12 &18 Bedrooms 12 &18 Bedrooms 12 &18 Bedrooms 12 &18 Bedrooms 12 &18 INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC Window _gt- wd_- Len. Overhang Hgt. xt. Rpt. Left Fin -Ust. Len. gt. Right Fin -15t: Len. Hgi. 1None 1.uu 2 Bug Screen 0.76 8.0 1.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0.1 2.0 0 3 Bug Screen 0.76 8.0 1.0 0.0 0.0 0.0 0.0 0.1 2.0 0 0.1 2.0 0 4 Bug Screen 0.76 8.0 1.0 0.1 4.0 0 0.0 0.0 0 5 Bug Screen 0.76 10.0 10.0 4.0 0.1 4.0 4.0 0.1 2.0 0 0.1 2.0 0 fi Bug Screen 0.76 10.0 20.0 6.0 0.1 6.0 6.0 7 Bug Screen 0.76 10.0 15.0 6.0 0.1 6.0 6.0 -�0 _ -0-0 -0 8 Bug Screen 0:76-6-.7 -0:7 0-1 0 0-0 9 Bug Screen 0.76 10.0 3.0 0.0 0.0 0 0.1 4.0 0 10 11- Bug Screen Bug Screen 0.76_ 0:76 X0.0 3:0 0-1 4:0 6 0-6 0-0 6 12 Bug Screen -0-.76- :7fi13 13 BugScreen 0.76 10.0 6.0 0.1 2.0 0 0.1 2.0 0 14 Bug Screen 076 8.0 0.7 0.1 4.0 0 0.0 0.0 0 15' Bug Screen 0:76- -8-0 T3 0-1 4:0 U 0-0 0-0 0 16 Bug Screen 0:76 8.0 7.0 2.0 0.1 2.0 2.0 17 Bug Screen 0.76 19Bug Screen -0-76- afif9 f9 Bug Screen O i6 • Run Initiation Time: 01/08/0410:01:23 Run Code: 1073584883 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:10 of 25 Computer Method Summary (Part 3 of 3) C -2R Ahob Smith -Custom Residence Insulation 1/8/04 MProiecTTiile Length -Date THERMAL MASS FOR HIGH MASS DESIGN Depth. Location / Comments Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight 653 3_50 28 0_98 n/a 2 Master Suite / Slab on Grade Concrete, Heavyweight 140 3.50 28 0.98 n/a 0 Master Suite / Slab on Grade Concrete, Heavyweight 118 3.50 28 0.98 n/a 2 Kitchen/Living/Entry / Slab on Grade Concrete, Heavyweight 1,133 3.50 28 0.98 n/a 0 Kitchen/Living/Entry / Slab on Grade Concrete, Heavyweight 749 3.50 28 ° 0.98 n/a 2 Bedrooms 12 818 / Slab on Grade PERIMETER LOSSES HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Central Furnace 80%AFUE Ducts in Attic 4.2 Central Furnace 80%AFUE Ducts in Attic 4.2 Wydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Setback HVAC -1 Setback HVAC -2 Setback HVAC -3 Cooling Equipment Minimum 'Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -1 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -2 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -3 WATER HEATING SYSTEMS Water Heater System Name AMERICAN G62-100T88-4NV Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Distribution # in Input Cap. or Recovery Standby R -Value Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Large Gas Recirc/Time+Temp 1 88,000 100 0.81 0.0244 12.0 1 For small gas storage (rated input <= 75000 Btulhr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btulhr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 01/08/04 10:01:23 Run Code: 1073584883 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 25 F2 Insulation Type Length Factor R -Val. Depth. Location / Comments Slab Perimeter 49 0.76 0.0 0 Master Suite Slab Perimeter 63 0.76 0.0 .0 Master Suite Slab Perimeter 22 0.76 0.0 0 Kitchen/Living/Entry Slab Perimeter 72 0.76 0.0 0 Kitchen/Living/Entry Slab Perimeter 76 0.76 0.0 0 Bedrooms 12 818 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Central Furnace 80%AFUE Ducts in Attic 4.2 Central Furnace 80%AFUE Ducts in Attic 4.2 Wydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Setback HVAC -1 Setback HVAC -2 Setback HVAC -3 Cooling Equipment Minimum 'Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -1 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -2 Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback HVAC -3 WATER HEATING SYSTEMS Water Heater System Name AMERICAN G62-100T88-4NV Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Distribution # in Input Cap. or Recovery Standby R -Value Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Large Gas Recirc/Time+Temp 1 88,000 100 0.81 0.0244 12.0 1 For small gas storage (rated input <= 75000 Btulhr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btulhr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 01/08/04 10:01:23 Run Code: 1073584883 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 25 Computer Method Summary (Part 3 of 3) C -2R ob Smith -Custom Residence 1/8/04 roject Title -Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight 258 3_50 28 0_98 n/a 0 Bedrooms 12 &18 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R-VaI. Depth Location / Comments Slab Perimeter 48 0.76 0.0 0 Bedrooms 12 &18 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments �ydronic Piping Pipe • Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap. cooling) (SEER) (attic; etc,) Duct Thermostat R -Value Type Location / Comments WATER HEATING SYSTEMS Ratedl Tank Energy Fact? 1 Tank insult Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btulhr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 01/08/04 10:01:23 Run Code: 1073584883 EnergyPro 3.1 By EnergySoft User Number: 5533 Jcb Number: Page: 12 of 25 41 Computer Method Summary (Addendum) C -2R ob Smith -Custom Residence 1/8/04 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan I Field The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 653 sqft Covered Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 140 sqft Exposed Slab Floor, 3.50" thick at Master Suite The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C-211) - Verify Thermal Mass: 118 sqft Covered Slab Floor, 3.50" thick at Kitchen/Living/Entry HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1133 sqft Exposed Slab Floor, 3.50" thick at Kitchen/Living/Entry The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C-211) - Verify Thermal Mass: 749 sqft Covered Slab Floor, 3.50" thick at Bedrooms 12 & 18 HIGH MASS Design(see C-211) - Verify Thermal Mass: 258 sqft Exposed Slab Floor, 3.50" thick at Bedrooms 12 & 18 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS N'uvwc1. r IV IOLWI unaai uwunIcnL uIc ncru vcnni,auvn aIru uiaynwuc rcauny UI areae mcaaurra un a wnn %,r -or%. an ie ld �The ys em- inc u es a rigeran Charge an i ow credit ora certifiedrater-m--u-sf—provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAG System is using reduced uc leakage to comply and must have diagnostic site tes1i_ng__oTU_uct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAG System includes Refrigerant Charge and Airflow Credit (ora certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System is using reduced u leakage to comply and must have diagnostic site testing of ductleakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. I Run InitiationTime: un Code: 1073584883 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 13 of 25 IHVAC.SYSTEM HEATING AND COOLING LOADS SUMMARY 05-ROJECT NAME DATE Bob Smith -Custom Residence 1/8/04 YSTEM NAME FLOOR AREA HVAC -1 793 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 71,000 Total Output (Btuh) 71,000 Output (Btuh/sgft) 89.5 Cooling System Output per System 47,000 Total Output (Btuh) 47,000 Total Output (Tons) 3.9 Total Output (Btuh/sqft) 59.3 Total Output (sgft/Ton) 202.5 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 2.02 Airflow (cfm/Ton) 408.5 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions 26.0 of 69.6 OF Outside Air Q 0 cfm Supply Fan 1600 cfm 69.6 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 486 10,495 0 317 13,806 0 525 690 0 0 0 0 0 0 0 0 0 525 690 11,544 0 15,187 CARRIER 38HDC04832 35,628 3,307 71,000 Total Adjusted System Output 35,628 3,307 1 71,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am earn I emDera ures at Time O ea Ina ea 69.6 of 111.3 of Heating Coil S, Return Air Ducts t4 Supply Air Ducts 110.9 of ROOMS 70.0 of UULIM3 JTJ I Cm t'JTUr1KUMt I KIDS (Airstream I emperatures at I Ime OT k;oonng reaK) 111.0/77.6OF 74.3/60.3OF 74.3/60.3OF 53.4/52.3OF 311 :111114 O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 53.7 / 52.4 of 1600 cfm 44.8% R.H. ROOMS 74.3/60.3 of 74.0 / 60.2 of �, Return Air Ducts q EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 14 of 25 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY leOJECT NAME DATE Bob Smith -Custom Residence 1/8/04 YSTEM NAME FLOOR AREA HVAC -2 1,251 Number of Systems 1 Heating System Output per System 89,000 Total Output (Btuh) 89,000 Output (Btuh/sgft) 71.1 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sqft) 46.4 Total Output (sgft/Ton) 258.8 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.60 Airflow (cfm/Ton) 413.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 1,22 25,666 0 586 25,319 0 1,283 1,266 0 0 0 0 0 0 0 0 0 1,283 1,266 28,23]377770 CARRIER 38HDC06032 44,610 3,608 Total Adjusted System Output (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK 44,6101 3,608 Aug 2 pm '-ILA I INN JYJ I LM I-bTL;NKUMt I KII:J (Airstream I emperatures at I Ime OT meating I-eaK) 26.0 OF 69.4 of 69.4 OF . 111.20F Outside 0 cfm 69.4 of 11.0 / 77.6 OF Outside j 0 cfm: 74.6/60.5 of Supply Fan Heating Coil 2000 cfm m 74.6/60.5 OF 74.6/60.5 OF 89,000 89,000 Jan 12 am Supply Air Ducts 110.6 of ROOMS 70.0 OF Return Air Ducts I res 53.6 / 52.5 of Supply Fan Cooling Coil 2000 cfm k Return Air Ducts 4 Supply Air Ducts 54.2 / 52.8 of 45.2% R.H. ROOMS 74.0 / 60.3 OF EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:15 of 25 —1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY OJECT NAME DATE Bob Smith -Custom Residence 1/8/04 SYSTEM NAME FLOOR AREA HVAC -3 1,007 ENGINEERING CHECKS SYSTEM LOAD CFM per System 1,buu Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.59 Airflow (cfmrron) 408.5 I Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of Outs 0 cfm . 69.5 OF 11.0 / 77.6 of -- Outside 0 cfm 74.4/60.4 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD HVAC EQUIPMENT SELE COIL COOLING PEAK IICOILHTG.PEAK CFM I Sensible Latent I I CFM I Sensible 69 14,770 0 359 15,578 0 739 779 0 0 0 0 0 0 0 0 0 739 779 16,247 0 CARRIER 38HDC04832 35,675 3,315 Total Adjusted System Output (Adjusted for Peak Design Conditions) 35,675 3,315 17,135 71,000 71,000 TIME OF SYSTEM PEAK F Aug 2 pm Jan 12 am mnera ures at Time of Heatinq ea 69.5 of 69.5 of 111.20F Supply Fan Heating Coil 1600 cfm k Return Air Ducts 4 74.4 / 60.4 of 74.4 / 60.4 of 53.5 / 52.3 of 0 Supply Fan Cooling Coil 1600 cfm EnergyPro 3.1 By EnergySoft User Number: 5533 Return Air Ducts Job Number: Supply Air Ducts 110.8 of ROOMS 70.0 of I Supply Air Ducts 53.9152.5 of 44.9% R.H. ROOMS 74.0 / 60.2 of Page: 16 of 25 ROOM LOAD SUMMARY ROJECT NAME Bob Smith -Custom Residence DATE 1/8/04 YSTEM NAME HVAC -1 FLOOR AREA 793 IROOMT= SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Master Suite Master we - 1 486 10,495 0 486 10,495 0 317 13,806 I PAGE TOTAL 486 10,495 0 317 13,806 TOTAL 486 10,495 0 317 13,806 EnergyPro 3.1 By EnergySoft User Number. 5533 Job Number: Page: 17 of 25 ROOM LOAD SUMMARY _LPROJE NAME Bob Smith -Custom Residence DATE 1/8/04 YSTEM NAME HVAC -2 FLOOR AREA 1,251 IROOM LOAD SUMMARY I ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Kitchen/Living/Entry i c en rving n ry 1 1,221 25,666 0 1,221 25,666 0 586 25,319 i . PAGE TOTAL '1,221 25,666 0 586 25,319 TOTAL 1,221 25,666 0 586 25,319 EnergyPro 3.1 By EnergySoft User Number. 5533 Job Number: Page: 18 of 25 TOTAL - 691 14,770 0 359 15,578 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 19 of 25 ROOM LOAD SUMMARY d6ROJECT NAME Bob Smith -Custom Residence DATE 1/8/04 YSTEM NAME HVAC -3 FLOOR AREA 1,007 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE' Bedrooms 12 &18 Bedrooms 1 691 14,770 0 691 14,770 0 359 15,578 r PAGE TOTAL 1 691 14,770 0 359 15,578 TOTAL - 691 14,770 0 359 15,578 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 19 of 25 ROOM HEATING PEAK LOADS Wob oject Title Date Smith -Custom Residence 1/8/04 Room Information Design Conditions Room Name Master Suite Time of Peak Jan 12 am Floor Area 793 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 786.3 X x x X x x x x X x X x x x x X X x x X x x x X x x x X X x x x x x X X X X x 0.0280 x X X x X x x X x X x X X x x X x X x x x x x x X x X X X x x x x x X X X x X 6.7 0.8000 952.0 0.0592 16.0 0.7200 42.0 0.7200 100.0 0.7500 perimeter =112.0 Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Infiltration: I1.00 x 1.064 x 793 x 11.00 X 0.00 / 6G1 x Sche u e Air ensi a Area Ceiling Height A Fraction Page Total pT 969 236 2,480 507 1,331 3,300 4,984 13,806 TOTAL HOURLY HEAT LOSS FOR ROOM 13,806 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:20 of 25 ROOM HEATING PEAK LOADS oject Title Date ob Smith -Custom Residence 11/8/04 Room Information Design Conditions Room Name Kitchen/Livingrentry Time of Peak Jan 12 am Floor Area 1,251 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT °F Btu/hr 1,251.0 X X X X x X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 X X X X X X x x x x x x. x x x x x x x x x x x x x x x x x x x x x x x x x x x 583.0 0.0592 350.0 0.7500 5.0 0.7200 135.0 0.7200 48.0 0.9900 perimeter = 94.0 Items shown with an asterisk (`r) denote conduction through an interior surface to another room. Infiltration: I 1.00 x 1.064 x 1,251 x 812.90 x 0.00 / 6G x L c e u e Air Sensible Area ei m ei t AC J Fraction Page Total pT 25,319 TOTAL HOURLY HEAT LOSS FOR ROOM 25,319 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 21 of 25 ROOM HEATING PEAK LOADS roject Title Date ob Smith -Custom Residence 11/8/04 Room Information Design Conditions Room Name Bedrooms 12 818 Time of Peak Jan 12 am Floor Area 1,007 Outdoor Dry Bulb Temperature 260E Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr x X x X X x X x x x X X x x x X x X X x X x X x X X X X X x x X X X x x X X x 0.0280 x X X X x X X X x X X x x X X x X X x x X x X X x X X x x X x x x X X X X X X 0.0592 0.7200 0.7500 0.7200 0.3872 Items shown with an asterisk (') denote conduction through an interior surface to another room. Infiltration:1.00 x 1.064 x 1,007 x 9.80 x 0.00 / 6] x U u e Air sensible Area Ceiling Height Fraction Page Total 0 pT 15,578 = 0 • TOTAL HOURLY HEAT LOSS FOR ROOM 15,578 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:22 0 25 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Bob Smith -Custom Residence 1/8/04 Project Title Date Room Name Master Suite Design Indoor Dry Bulb Temperature: 740E Design Outdoor Dry Bulb Temperature: 1120F Design Temperature Difference: 380E Conduction R-38 Roof (R.38.2x14.16) Skylight R-21 Wall (W.21.2x6.16) Glass Block Double Metal Low a sq Double Metal Low a sq Area U -Value 1 6.1 0.7200 0.7500 X X X X X X DETD 1 = = = = = = Btu/hr 55.0 1,211 38.0 204 34.6 1,950 38.0 438 38.0 1,149 38.0 2,850 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 7,802 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr • • Skylight (Skylight) ( 0.0 13 (East) ( 0.0 12 (South) ( 0.0 11 (West) (_0.0 10 (North) ( 0.0 390 42.0 32) 0.512 688 E1 1 8.0 73)x 0.668 390 1 100.0 X X x x X x x X x XL 1+ + + + + + + + + + 6.7 X X x X X X X X x X 152) X x X X )X )X )X )X )X 0.448 = = = = = = = = = 457 1 8.0 73) 0.668 390 42.0 32) 0.512 688 E1 1 8.0 73)x 0.668 390 1 100.0 15) 0.512 768 Sched. Page Total F777iiiil Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 793 X 0.000 Watts/sqft x 3.41 BtuhfWati 0 Occupants 1.00 x 793 X 0 Btuh/occ. / 20,000 sgft/occ. = 0 Receptacle 1.00 X 793 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Process 1.00 X 793 X 0.000 Watts/sgft x 3.412 BtuhlWatt = 0 Infiltration: [ 1.00 x 1.064 x 793 x 11.00 X 0.00 / 60] Schedu a Ari Sensib a rea ening Feig AC p Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,495 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 793 x 0 Btuhlocc. 1 20,000 sqft/occ. = 0 Receptacle 1.00 X 793 x 0.000 Watts/sqft x 3.41 Btuh[Watt = 0 Process 1.00 x 793 x. 0.000 Wattslsgft x 3.413 Btuh[Watt = 0 Infiltration:[ 1.00 x 4,771 x 793 x 11.00 x o.00 / 60] o.00000 = 0 s e1 a Air'La of nt Area ceiling Ac pW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 23 of 25 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Bob Smith -Custom Residence 1/8/04 Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof (11.38.2x14.16) R-21 Wall (W.21.2x6.16) Double Metal Low a sq Glass Block Double Metal Low a sq ingle NonMtl Tinted Default Area 1 1,251.0 1 Date U -Value x 0.0280 x 0.0592 x 0.7500 x 0.7200 x 0.7200 x 0.9900 x 38.0 x 1,152 x 1 Kitchen/Living/Entry 740F 112°F 38OF x X x x X x DETD 1 = = = = = = Btu/hr 55.0 1,927 34.6 1,194 38.0 9,975 38.0 137 38.0 3,694 38.0 1,806 x x x 1. Design Equivalent Temperature Difference (DETD) Page Total 18,732 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr • 9 (North) 9 (North) 14 (South) 1 '(South) 1 (South) 1 (South) D1 (South) 2 (West) 1,152 ( 0.0 1 5.0 ( 0.0 x X x x x x1 x x x x All + + + + + + + + + + 200.0 x X x x X x x x x X 15)X X )x )x 0.512 = = = = = = = = 1,536 ( 0.0 150.0 15)x 0.512 1,152 ( 0.0 1 5.0 -32)x 0.668 107 ( 0.0 1 30.0 32)X 0.512 492 ( 0.0 1 15.0 -32)x 0.512 246 ( 0.0 30.0 -32)X 0.512 492 ( 0.0 1 48.0 32) 0.434 667 ( 0.0 1 60.0 -73)x 0.512 2,243 ( ( Sched. Page Total 6,93a Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,251 X 0.000 Watts/sqft x 3.413 BtuhfWatt = 0 Occupants 1.00 X 1,251 X 0 Btuh/occ. / 20,000 sgft/Occ. = 0 Receptacle 1.00 x 1,251 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Process 1.00 x 1,251 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Infiltration: x ei1 1.064 X 1,251 x 12.00 X 0.00 /60 LcelOeo it ensi a Area . -ng Fr.gh- ACO Q Fraction TOTAL HOURLY SENSIBLE HEAT GAIN! FOR ROOM 25,666 Sched. Latent Gain Frac. Area Heat Gain Btulhr Occupants 1.00 X 1,251 x 0 Btuh/occ. / 20,000 sgft/occ. = 0 Receptacle 1.00 x 1,251 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Process 1.00 x 1,251 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: [ 1.00 x 4,77 x 1,25 X 12.00 X 0.00 / 60] 0.00000 = 0 Sc�ie u e it Latent Area Ceilm' gg eigh AC �yy 40 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 24 of 25 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Bob Smith -Custom Residence 1/8/04 Project Title Date Room Name Bedrooms 12 & 18 Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: 74°F 112°F 380F Conduction Area U -Value DETDBtu/hr x (North) 55.0 = 1,551 x 8 34.6 = 2,088 x ( 0.0 38.0 = 465 x (West)" 38.0 = 3,192 X 24.0 38.0 = 1,313 X 24.0 34.61 = 322 X X x 1. Design Equivalent Temperature Difference (DETD) Page Total 8,931 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 3 (North) ( 0.0 4 (North) ( 0.0 8 (East) ( 10.5 7 (East) ( 0.0 6 (East) (-0.0 5 (West)" ( 0.0 0.512 1,782 E1 1 24.0 -73)x 0.512 897 1 24.0 73) 0.512 897 x x x x x x x X x X 1 I + + + + + + + + + + 6.0 X x X x x X x x x)x X 15) X X X x )x )X )X 0.668 = = = = = = = _ 60 1 11.0 15) 0.668 110 45.5 73) 0.512 1,782 E1 1 24.0 -73)x 0.512 897 1 24.0 73) 0.512 897 1 56.0 73)X 0.512 2,093 Sched. Page Total S,84o Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,007 x 0.000 Watts/sgft x 3.411 Btuh/Waft = 0 Occupants 1.00 X 1,007 x 0 Btuh/occ. / 20,000 sgft/occ. = 0 Receptacle 1.00 X 1,007 x 0.000 Wafts/sgft x 3.413 BtuhfWatt = 0 Process 1.00 x 1,007 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: _ 1.00 x 1.064 x 1,007 x 9.80 x 0.00 /60 38 = Schedule A'ir Sens�tile Area elm' g ReigFi AC pT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,770 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1,007 x 0 Btuh/occ. / 20,000 sgft/occ. = 0 Receptacle 1.00 x 1,007 x 0.000 Watts/sgft xJ 3.413 Btuh/Watt = 0 Process 1.00 X 1,007 X 0.000 Watts/sqft x 3.413 BtuhlWatt = 0 Infiltration: [ 1.00 x _ 4,77 x 1,00 x 9.80 x 0.00 / 60] 0.00000 = Schedule Air Latent Area Ceil- He.gh AC pW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 25 of 25