06-3991 (PAT)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 00.0
Property Address:
45580CS.T-ONEBROOK CT
APN:
604-404-.024-9 -23995 -
Application description:
PATIO COVER - RESIDENTIAL
Property Zoning:
LOW DENSITY RESIDENTIAL
Application valuation:
3830
Applicant: Architect or Engineer:
LICENSED CONTRACTOR'S DECLARATION
(
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code; and my License is in full force and effect.
License Class: B License No.: 758936
ate 'ontractor,_C.- A�� , -
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation'of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 _ I I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code:- The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
` one year of completion, the owner -builder will have the burden of proving that he or she did not build or'
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project ISec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
( ) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERA11T
Owner:
FAZZONE MARCY A
C/O DAVID FAZZONE
UNKNOWN, CA 99999
VOICE (760) 777-7012
. FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 12/01/06
Contractor:
PATIOS N STUFF
4145 NINTH STREET D
RIVERSIDE, CA 92501('51)71
-0010
Lic. Nos: 758936
Cj
u
Application Number . . . . . 06-00003991
Permit ELEC-MISCELLANEOUS
Additional desc
Permit Fee . . . . 18.00 Plan Check
Fee
4.50
Issue Date . . . . Valuation
. .
0
Expiration Date 5/30/07
Qty Unit Charge Per
Extension
BASE FEE
15.00
• 4.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20
--------------------------------------------------------------------------------
3.00
Permit . . . PATIO COVER PERMIT
Additional desc .
Permit Fee 63.00 Plan Check
Fee
40.95
Issue Date . . . . Valuation
3830
Expiration Date 5/30/07
Qty Unit Charge Per
Extension
BASE FEE
45.00
2.00 9.0000 THOU. BLDG 2,001-'25,000
18.00
--------------
--------------------------------------------------------------
Special Notes and Comments
12x24 patio enclosure with2 fans and
outlets. per.ICBO,ER-4383-p-kl22. THIS
ENCLOSURE SYSTEM IS LIMITED TO
RECREATION AND OUTDOOR LIVING PURPOSES
AND IS NOT TO BE.USED AS A
CARPORT,GARAGE,STORAGE OR HABITABLE
ROOM:December 1, 2006 8:54:10 AM
jjohnson
-----------------------------------------
- Other Fees . . . . . . ... ..STRONG MOTION.(SMI)
- RES
.50
Fee summary Charged Paid Credited
Due
Permit Fee Total 81.00 .00
.00
81.00
Plan Check Total 45.45 .00
.00
45.45
Other Fee Total .50 .00
.00
:50`
Grand Total. 126.95 :00
00
126.95
LQPERAIIT
Bin #
FCO,'
-City of La Quinta
Building U Safety Division.
Permit if I
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760)'777-7012
'
Building Permit Application and Tracking Sheet
Project Address: LMtJ��
Owner's Name:
A. P. Number.
Address: - L j S
Legal Description:
City, ST, Zip:
Contractor: -�S
Telephone 7(96
Address: -L l n h
Project Description:
.City, ST, Zip:
X J
Telephone: qgl 71 E; _
State Lic. # :. 'Z
City Lic. #:
S
Arch., Engr., Designer:
Address:
City,.-ST, Zip:
Telephone:
Construction Type: occupancy:
P cY:
-
State Lic. #:
Project type (circle one): New Add'n Alter 'Repair Demo
Name of Contact Person: `
Sq:FL: 2
#stories-
#Units:
Telephone # of Contact Perso
Estimated Value of Project: `fes
APPLICANT:
DO NOT WRITE BELOW THIS LINE
N
Submittal
P;w
Req'd
Recd
TRACMG .
PERMIT FEES
.
Plan Sefs
-
Plan Check submitted
tted
�•
Item
Amount
v
9f�au iu a Cal
Reviewed, ready for corrections
.2�
Plan-Check Deposit
Truss Cales.
Called Contact Person
Plan Check Balance
-
Energy .Cales.
Plans picked up A7 il' G
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading.plan
Y' Review, ready for correc ' ns/�ssue
ZI
Electrical
Sabcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
Ii O A. Approval
Plan s resubmitted .
Grading
IN HOUSE:-
'''Review, ready for correctionsrssue
Developer Impact Fee.. ;
Planning Approval
Called Contact Person
A,I.P.P.
.Pub. Wks. Appr
Date of permit issue.
School Fees
-�Oni B0
ARD
.., .. Total.PermitFees ... .
j-6opil-5
L4
ft Q U'k r,.4A-
3 q q 90
'P F 19
-3j �
Hun
NOV 15. D
C
I
2001 CALIFORNIA BUILDING CODE
.Division IIF—PATIO COVERS
SECTION 3116 — PATIO COVERS DEFINED
Patio covers are one-story structures not exceeding12 feet (3657
mm) in height. Enclosure walls may have any configuration, pro-
vided the open area of the longer wall and one additional wall is
equal to at least 65 percent of the area below a minimum of 6 feet
8 inches (2032 mm) of each wall, measured from the floor. Open-
ings may be enclosed with insect screening or plastic that isrieadi
_J .�---- �---�
ly �removable-translucent;or transparent„pl'astic not:more'_than
0.125'' in&(3.1mm)' in -thickness.
Patioo covers may be detached or attached to other buildings as
accessories to Group U; Group R, Division 3; or single dwelling
units in Group R, Division 1 Occupancies. Patio covers shall be
used only for recreational, outdoor living purposes and not as car-
ports, garages, storage rooms or habitable rooms.
SECTION 3117 — DESIGN LOADS
Patio covers shall be designed and constructed to sustain the loads
required by Chapter 16, combined in accordance with Section
1612.2 for load and resistance factor design or Section 1612.3 for
allowable stress design, except that the live load; L, shall not be
taken as less than 10 pounds per square foot (0.48 kN/m2) and,
TABLE A-31-A—DESIGN WIND
APPENDIX CHAPTER 31
where less than, 12 feet (3658 mm) high, the horizontal wind load
shall be as indicated in Table A -31-A. In addition, they shall be de-
signed to support a minimum wind uplift equal to the horizontal
wind load acting vertical upward normal to the roof surface, ex-
cept that for structures not more than 10 feet (3048 mm) above
grade the uplift may be three fourths of the horizontal wind load.
When enclosed with insect screening or plastic that is readily re-
movable translucent or transparent plastic not more than 0.125
inch (3.2 mm) in thickness, wind loads shall be applied to the
structure, assuming it is fully enclosed.
SECTION 3118 — LIGHT AND VENTILATION
Exterior openings required for light and ventilation may open into
a patio structure conforming to Section 3116.
SECTION 3119 = FOOTINGS
A patio cover may be supported on a concrete slab on grade with-
out footings, provided the slab is not less than 31/2 inches (89 mm)
thick and further provided that the columns do not support live and
dead loads in excess of 750 pounds (3.34 kN) per column.
1� �vE A•
G� I�G & SAF
gU11-� Fko\j
o�C�NSTRUC
F
BY
IDAT.,
FOR-PATIO COVERSI
WIND SPEED --AAP AREAS (miles per hour)
HEIGHT ZONE x 1.61 for km/li
IN FEET 70 60 90 100 110 120 130
x 304.6 for mm - x 0.046 for kWm2 (psf) -
Lessthan 12 10 13 15 19 23 27 32
iee Chanter 16_ Figure 16-1 _ fnr hasir wind --de
1-405