Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BRER2017-0032
78-495 CALLE TAMPICO . LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: c&tr4XPRd&r�, DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 BRER2017-0032 Owner: 79600 N N TOM FAZIO LN LN LEON BOSTICK 766031019 79600 N TOM FAZIO LN BOSTICK / REROOF ENTIRE DWELLING WITH CLASS "A" FOAM OVER EX LA QUINTA, CA 92253 $51,360.00 Applicant: FOAMBOND CORPORATION 255 N EL CIELO RD STE 140-656 PALM SPRINGS, CA 92262 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License'is in full force and effect. License Class: C39 License No.: 868171 Date.. / OC -d OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. . B.&P.C. for this reason Date: Owner: . CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit. is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: Date: 33//15/201 ¢ z C� LU 255 N EL CIELO RD STE 140-656 U 2 PALM SPRINGS, CA 92262 a LU CD z N Q W Lo O r� t,►- J Contractor: a FOAMBOND CORPORATION ¢ C) LU Q 255 N EL CIELO RD STE 140-656 U 2 PALM SPRINGS, CA 92262 z c3 (866)404-5440 Q w Llc. No.: 868171 M WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Se�ion 700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: CALIFORNIA INSURANCE COMPANY Policy Number: 4684631401 _ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: %3 // .5—// fFAoo�" WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION'3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed -under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. Date: -'3 <<s /� ';*S-ignature (Applicant or Agent):ed-e-e-L11-19.1 i Date: 3/15/2017 Application Number: BRER2017-0032 Owner: Property Address: 79600 N N TOM FAZIO LN LN LEON BOSTICK APN': 766031019 79600 N TOM FAZIO LN Application Description: BOSTICK / REROOF ENTIRE DWELLING WITH CLASS "A" FOAM OVER EX LA QUINTA, CA 92253 Property Zoning: Application Valuation: $51,360.00 Applicant: Contractor: FOAMBOND CORPORATION FOAMBOND CORPORATION ' 255 N EL CIELO RD STE 140-656 255 N EL CIELO RD STE 140-656 PALM SPRINGS, CA 92262 PALM SPRINGS, CA 92262 (866)404-5440 --------------------------------------------------------------------------------------------- Llc. No.: 868171 Detail: REROOFWITH CLASS "A" FOAM OVER EXISITNG FOAM AT FLAT ROOF PER 2016 CALIFORNIA ENERGY CODE. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $3.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $3.00 DESCRIPTION ACCOUNT QTY AMOUNT RE -ROOF - EA ADDITIONAL 1,000 SF 101-0000-42404 0 $133.76 DESCRIPTION ACCOUNT QTY AMOUNT RE -ROOF -FIRST 2,000 SF 101-0000-42404 0 $51.68 DESCRIPTION ACCOUNT. QTY AMOUNT RE -ROOF - FIRST 2,000 SF PC 101-0000-42600 0 $103.36 Total Paid for RE -ROOF: $288.80 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 . Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 r. Bin Permit u Pro"cet Address: "' J Q .,o?" .0 ty of La Quin to Building 8z' Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-701,2 Building Permit Application and Tracking Sheet i p N. L Owner's Name: U14 A. P_ Number: OWn+e, Address: ��.�' G� , b ►br Legal Description: City, ST, Zip: to Quiht 1-1` Contractor: r• o. �b� Telephone: _ Gr h .Gr►6G � � C Address: V S fy, r� p _ S3 Project Description: L rp p,F City, ST, Zip: I %,� tri -5 • --• ST, C� 6 � � � eC � l o to St 112 (r �i TeleP hone: 9 6 7 y I w 7 r Gl 6 4 State Lic. # : $'(o 7 j City Lie.#.: s r, ...% o S S Y) d'G Arch.,'Engr., Designer: j fry s Address: City, ST, Zip: Telephone: ................................................ an c cti n Type: Occupancy: on truoY C s P (9 Y: r o� State L#. ic. r Demo Project type (circle one • New Ad d'n Alter Repair.ai o Name of Contact Person: Sq. Ft.: Ga r-f (- # Stories: # Units: Telephone # of Contact Person: Estimated Value of Pro.ect0,5 o . 6 0 APPLICANT: DO NOT WRITE BELOW THIS LINE t✓ Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact person Plan Check Balance • , Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans kicked up S.M.I. 1-I.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date or permit issue School Fees, Total Permit Fees 1CC �prr Ke vrc STATE OF CALIFORNIA 1i'S C Iris -S A RESIDENTIAL ALTERATIONS , CEC-CFIR-ALT-01-E Revised 09116 CALIFORNIA ENERGY COMMISSION "WW' CERTIFICATE OF COMPLIANCE MR -ALT -01 -.E - Prescriptive Residential Alterations (Page 1, of 6) Project Name:` Date Prepared: A. General Information 01 02 01Project Name: 02 Date Prepared: J k 03 Project Location: 7-94,00 a in ib rvra-k 04 Building Front Orientation (deg or cardinal): ,\ . `3 05 CA City: ®" •r -l -e- 06 Number of -Altered Dwelling.Units: 07 Zip Code: da 3 08 Fuel Type:, 09 Climate Zone: 10 Total Conditioned Floor Area,(;ft�) t) w 11 Building Type: 12 1 Slab Area (ft'): 13 Project Scope: 14 Exceptions to Minim YJij f&solar Reflectance and Minimum Therrf al EAftance or SRI..'. •B. Building Insulation Details - Framed (Section 150.2(b)1) + 01 02 03, 04 05 06- �* "`07 1, 08{ s09 10 11 Tag/ID M - Assembly Type Frame Type Frame Depth (inches) Frame . Spacing (inches) Rf oposed Required ._ Comments Cavity R-val0e VA ' Continuous eInsulation ; R -value, o"Upaf etor Appendix JA4 - Reference - U Factor Table: Cell ;. t Note: _ . •. Where insulation is installed above the roofing mem bra ve;-or• ab . ethe layer used to eal the roof f'romrWR& penetration, the insulation shall have a maximum water absorption of 0.3 percent by volume when tested according to ASTM(5ta dard C272. , 'S4. ff.P i& � 101T LN& C. Building Insulation. Details - Non -framed , 01 02 03\ V. '` 05, %• 06' 07 O8 09 10 11 ` Tag/ID - - .. AssemblyType. 9 • • • Assembly Materials s' • �. _ Thickness inches (• ) Ap A Proposed Required Comments r C66rreV llulation R -value Continuous Insulation R -value U -factor Appendix JA Reference Required..- Table Cell- U -factor from> Package A Registration Number: Registration Date/Time: ' CA Building Energy Efficiency Standards - 2016 Residential Compliance HERS Provider: September 2016 STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS � ,"Y _EG-GFIR-ALT-01-E (Revised 09/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ALT-01-E Prescriptive Residential Alterations (Page 2 of 6) Project Name: Date Prepared: D. Building Insulation Details — Mass Walls 01 02 03 04 05 06 07 08 09 10 11 Tag/ID Wall Above Grade Mass Type Mass Thickness (inches) Interior Furring Strip Thickness (inches) Exterior Furring Strip Thickness (inches) Proposed Required Interior Insulation Exterior Insulation p0'e)dl)dA4 o'! f2''2ference Interidr'Insulation Exterior Insulation R -value U -factor R -value q� U=facto ,,,,,#Table +++� �s �CeR value U -factor R -value U -factor ! Fenestration CRRC Fenestration Allowed Allowed Proposed -44i' ' Minimum Required a Orientations Area Only Aged Solar Aged Solar U -factor U -factor SHGC SHGC Type Product ,,,,41) 4S R -value Tag/ Method of Roof (Skylights) ID Product ►xl_�Ws_Wq E. Roof Replacement (Section 150.2(b)1H) ftf 01 02 03 ` , '" q"�p40 y, '� ' �" 05 06 07 Maximum IVlaximum' '�� :'.. 01 02 03 04 05 06 07 08 9- 10 11 12 13 14 Area Fo rAI ! Fenestration CRRC Fenestration Allowed Allowed Proposed -44i' ' Minimum Required a Orientations Area Only Aged Solar Aged Solar U -factor U -factor SHGC SHGC Type Product ,,,,41) 4S R -value Tag/ Method of Roof (Skylights) ID Product Deck �In ia) Solar Aged Sc Thermal SRI Reflectance Reflectance Thermal SRI ID Compliance Pitch Exception Number Type Insulation �Raflectance RefleCtce Emittanc.elt(Optional) (Max) (Min) Emittance (Optional) f N, ` Notes: ` `✓ • Roof area covered by building integrated photovoltaic.,pa'nels s id solar thefm els are exe no'Ur the above Cool Roof requirements. • Liquid field applied coatings must comply with igstalla iCn criteria from s�[tiofi 110.8(1)4. F. Fenestration/Glazing Allowed AreasRand`Effieiencies (Section#150.2(b)1) 01 02 03 ` , '" q"�p40 y, '� ' �" 05 06 07 Maximum IVlaximum' '�� :'.. Allowed Fenestration-_. Allowed West- ' Facing EE istill �FIehelsltration Existing..Wee }'> Facin Maximum Maximum Maximum Maximum Area Fo rAI ! Fenestration Area for All Fenestration Allowed Allowed Allowed Allowed Alteration Orientations Area Only Orientations Area U -factor U -factor SHGC SHGC Type (ft 2)V ,,,,41) 4S (ft2) (ft) (Windows) (Skylights) (Windows) (Skylights) Comments M Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance September 2016 STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS �� 311 C_ EC-CF1R-ALT-01-E (Revised 09/16) CALIFORNIA ENERGY COMMISSION 'RP' .CERTIFICATE OF COMPLIANCE MR -ALT -01-E Prescriptive Residential Alterations (Page 6 of 6) Project Name: Date Prepared: DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: c Documentation Author Signature: d Company: Signature Date: 9� Address: l \((-,5 +e, C.h;to CEA/ HERS Certification Identification((if,appllFable): -£s3 [�� City/State/ZiP: ii 1 rh 1 r 1^� 5 C. A -/�� (-o+L `v Phone: C RESPONSIBLE P.ERSON'S DECLARATION STATEMENT I certify the following underpenalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility f6ie ilding desigh of sate design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, anim ufactured devicof rnthe building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the Cali o 6iaa &e of Regulator . 4. The building design features or system design features identified on this Cerin of Complian�c�e,a nsistent with thinformation provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for � approva�`u�iith this bruai,lding a mit application. 5. 1 will ensure that a registered copy of this Certificate of Compliance sha5ll�be made availabl�With t�e building permiijs;Wssued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered c8py o��f t.;?Certificate of p`llce is requir�e�d.`tto beoNcluded with the documentation the builder provides to the building °i SIF owner at occupancy. Responsible Designer Name: `� `� Cetruk Responsibeslgiier Signature: Company:�'.Slgned: � )-.b��( Address: qW •?/? E yrs 4�h 0 5; N License: City/State/Zip: Phone: 410 Folr ssistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance September 2016 LPA -3000 - Roofing Foam Product Use and Design LPA 3000 is a two -component, closed -cell, polyurethane foam system specifically designed to provide a high performance; light weight roofing system for use over insulation water proofing a wide variety of roof deck construction and configurations. LPA 3000 locks in every portion of the roof creating a seamless membrane thus eliminating the need for mechanical fasteners — the number one cause of conventional roof leaks. LPA 3000 spray foam roofing can also be applied to vertical surfaces making the seamless coverage self -flashing. In addition to roofing applications, LPA 3000:1s also recommended for tank insulation applications. Product Advantages • Reduces installation time and costs • Decreases energy expenses compared to alternative solutions • Enhances resistance to wind uplift and hail damage • Provides a waterproof monolithic roof system • Offers a high R -value per inch Reactivity Selection Processing Winter Regular Summer Designation: Surface Temperature: 50-75°F I 60-90°F I above 85°F Heated trailers, hotboxes, or heated tank storage may be necessary. Material temperature should be confirmed with a thermometer or IR gun. Processing Parameters Optimum pressure, preheat and hose temperature will vary from machirie to machine. The performance of the foam system being'applied will'also,be affected by the ambient and substrate temperatures as well as wind. It is the responsibility of the. applicator to determine"he optimum: processing requirements--,,, sof his machinery as thes-'will change over the course of the day: The guidelinesshown,,below -should be used to determine a', starting point for this optimization process' )� , iDynamic PreheatPressure . erature Temperature F0AM=P_,&U-- SPRAY FOAM ROOFING 2:1 transfer pumps are recommended for material transfer from container to the proportioner. CAUTION: Extreme care must be taken when removing and reinstalling drum transfer pumps so as NOT to reverse the "A" and "B" components. Do not recirculate or mix other suppliers' "A" or "B" component into LPA 3000 containers. The plural component proportioner must be capable of supplying each component within ± 2% of the.desired 1:1 mixing ratio by volume. LPA 3000 should be applied in lifts or passes of no less than 1.0 inch and no more than 2.0 inch thickness per pass or lift. Minimal passes or reduced thickness will result in elevated density and may not cure properly, reducing the physical performance properties of the system. Applications of greater than 2 inches will result in reduced density and physical properties and may also create scorching of the foam as a result of the exothermic reaction, both of which will reduce the physical performance characteristics of the foam. Physical Properties Aged "R"Value: ASTM C-518 6.5 per inch Compressive ASTM D-1621 50-65 psi Strength: 40 min. Core Density: ASTM D-1622 2.9-3.2 Ibs./ft3 Closed Cell iTensile Strength: i Water Vapc rx f Permeability e_1 74°F; perm inch:,, 1,000 -1,400 psi .. 120 -130 ° F _ 120 -130 ° F "�""" u (49-540 C) (49 - 54° C).,„�w� tt Stability: 28 days s 158°17,J98%131-1 Y. • • 4M. Shelf Life.' p ASTM D-2856 90 min. >90% ASTM D:1623..__:---- 55_65. ,volume) ASTM E-969" 1.26 @ 1" 2.5 max If H ASTM D-2126, ly___ -1:50-1:80 6 months when stored wlthin:iecoi ' ' r per" temperature range -- ` . Ei 165 - 85° F S0 - 150 ° F 60 ` 80° F' . Coating TF Series Acrylic (18-300C) (.10 - 66° C) , (15 - 26° C) F ., } C e vv Recommendation: _Lapolla Industries,'Inc'.'I,15402 Vantage Parkway E. Ste. 322, Houston, Texas 77032 1 (888)4-LAPOLLA I www.lapolia.com LPA 3000 Roofing Foam Rev. Date: 10130113 Credentials/Certifications • Underwriters Laboratories Inc. File R14353 • ASTM E-84 Flame Spread Index <_75; Smoke Development >500 • Factory Mutual Global 4880/4470 . • Florida Building Code Approval #11066 • Dade County Approval • NOA#10-0513.01 LT. WT. Concrete NOA#09-0610.03 Concrete • NOA#09-0610.06 Recover • NOA#12-0605.07 Steel • NOA#09-0610:04 Wood • NOA#11-1101.05 Cementitious Wood Fiber • NOA#11-1101.06 Gypsum • California State Fire Marshall • California Bureau Of Home -Furnishings and Thermal Insulation Reg. NO. CA T444 (TX) Personal Protection/Material Safety and Handling Respiratory protection is MANDATORY! Contact Lapolla Industriesfora copy of the Model Respiratory Protection Program developed by API or visit their website at www.polyurethane.org. Persons with known respiratory allergies should avoid exposure FOArn-O.- SPRAY FOAM ROOFING In Case of Spills or Leaks:. • Utilize appropriate personal protective equipment • Ventilate area to remove vapors Contain and cover spilled material with a loose, absorbent material such as oil -dry, vermiculite, sawdust or Fuller's earth • Shovel absorbent waste material into proper waste containers • Wash the contaminated areas thoroughly with hot, soapy water • Report sizeable spills to proper environmental agencies In Case of Fire Extinguishing Media- Water, Carbon Dioxide, Foam or Dry Powder DISCLAIMER The data presented herein is not intended for use by nonprofessional applicators, or those persons who do not purchase or utilize this product in the normal course of their business. The potential user must perform any pertinent tests in order to determine the product's performance and suitability in the intended application, since final determination of fitness of the product for any particular use is the responsibility of the buyer. to the "A" component. The "A" component contains reactive. isocyanate groups while the "B" component contains amine and/ All guarantees and warranties as to products supplied by Lapolla or catalysts with blowing agents. Both materials must be handled Industries shall have only those guarantees and warranties and used with adequate ventilation. The vapors must not exceed expressed in writing by the manufacturer. The buyer's sole the TLV (0.02 parts per million) for isocyanates. Avoid breathing remedy as to any material claims will be against the applicator vapors. Wear a NIOSH approved respirator. If inhalation of vapors of the product. The aforementioned data on this product is occur, remove victim from contaminated area and administer to be used as a guide and is subject to change without notice. oxygen if breathing is difficult. The information herein is believed to be reliable, but unknown risks may be present. NO WARRANTIES, EXPRESSED OR Call a physician immediately. Avoid contact with skin, eyes; and `I1MPL1ED, INCLUDING PATENT WARRANTIES OR WARRANTIES clothing. Open containers carefully, allowing any pressure io be OF. MERCHANTABILITY OR FITNESS . FOR USE, AREMADE, relieved slowly and _safely Wear chemical safety goggles and' BY 'LAPOLLA WITH RESPECT—TI OUR-PR0DU SAOR" rubber gloves when"handling or working with these materials." -,,,INFORMATION SET.FORTH HEREIN,: _ •. In case of eye contact immediately flush with large arnounts`of waterforat leastfifteen minutes. Consult a physician immediately. h In case of skin contact wash area with soap and _water. Wash c clothes before reuse: o AWE u}) s Slf/�o d , TITLE MIAMEDADE U` FIVI '.. CR C a. 24 4©© APPROVED-,1PPR01`f.D.F ` j To the best of our knowledge, the technical data contained herein is true and accurate at the date. of issuance and is subject to change without prior notice. User must contact Lapolla Industries, . - Inc. to verify correctness before specifying or ordering. No guarantee ofaccuracyis given orimplied. We guarantee �our products to conform to Lapolla Industries, Ir .'s qualitycontrol. We assume no responsibility for coverage, performance or injuries `resulting from use. Lapolla Industries, Inc,. 1 15402"Vantage-Parkway E. Ste. 322, Houston, Texas 77032 1 (888) 4-LAPOLLA 1 www.lapolia.com 18/02'2016 Page Bottom See General Information for Roofing Systems PRO -TECH PRODUCTS INC 3003 N 73RD ST, SCOTTSDALE, AZ 85251-7204 USA TGFU.R16029- Roofing Systems TGFU.R16029 Roofing Systems Roofing Systems R16029 NCFI Polyurethanes "591 Series" urethane foam insulation may be used as an alternate to "Pro -Tech Urethane Foam" in any of the non- combustible systems listed below. Any of the systems listed below may be covered with a field mixed coating composed of "Pro -Tech Products Dry Mix" (40 -lbs), Rohm & Haas MC -76 (1/2 -gal), Rhone-Poulenc Colloid 622 (3/4 -oz), 41/: -gal. Water applied per 100-ft.2. Young Builders Roofing "DuraGard Roof Mix" may be used in lieu of "Pro -Tech Dry Mix II" in any of the following roofing systems. Any of the following Class A Spray Applied Foam and Coating Systems may be used as Maintenance and Repair Systems when applied over an existing roof covering system and shall maintain the existing roof classification, providing a minimum 1172 -in. thick foam Is used and maximum incline limitations are observed. 1. Deck: NC SPRAY APPLIED FOAM AND COATING SYSTEMS Incline: 1 Class A Foam: — "Pro -Tech Urethane Foam" insulation, min 1 in. thick. Base coat: — "EC -100", at 11/2 - gal/ 100-ft.z. Topcoat:;— "EC -100", at 1'/2-g6l/100-ft.2. 2. Deck: NC Incline: 1-1/2 Foam: — "Pro -Tech Urethane Foam" insulation, 1 in. thick. Base coat: — "EC -100", at 1'h-gal/100-ft.2. Topcoat: — "EC -100", at ilh-gal/100-ft.2. 3. Deck: NC Incline:.1/2 Foam: — "Pro -Tech Urethane Foam" or Polythane Systems SH -200-25 Insulation, min 1 in. thick. Base coat: — "EC -100", at 11h-gal/100-ft.2. Topcoat: — "EC -100", at 1'h-gal/100-ft.2. 4. Deck: C-15/32 Incline: 1/4 Foam: — "Pro -Tech Products Urethane Foam", or Polythane Systems SH -200-25 insulation, min 2 in, thick. Coating: — Two or three coats "EC -100", at 1-1/4 gal/sq/coat with "Pro -Tech. Granules" (not UL Classified) at 64 Ib/sq Imbedded into one of the wet coats. Surfacing: — Mixture of "Pro -Tech Products Dry Mix" (40 lbs), Rohm & Haas MC -76 (1/2 gal), Rhone-Poulenc Colloid 622 (3/4 oz) and water (4-1/2 gal.) spray applied per 100 sq ft. 5. Deck: C-15/32 Incline: 1/2 Impact: 1 Tape: — All joints in deck taped with one layer of 2 mil thick aluminum backed 2 in. wide tape. Foam: — "Pro -Tech Urethane Foam" insulation only, min 1 in. thick. Coating: Two or three coats "EC -100", at 1-1/4 gal/sq/coat with "Pro -Tech Granules" (not UL Classified) at 64 Ib/sq imbedded into one of the wet coats. Surfacing: — Mixture of "Pro -Tech Dry Mix I1" (40 lbs), Rohm & Haas MC -76 (1/2 gal), Rhone-Poulenc Colloid 622 (3/4 oz) and water at (3-1/2 to 4-1/2 gal.) spray applied per 100 sq ft. 6. Deck: NC Incline: Unlimited Impact: 1 Foam: — "Pro -Tech Urethane roam" insulation only, min 1 in. thick. Coating: — Two or three coats "EC -100", at 1-1/4 gal/sq/coat with "Pro -Tech Granules" (not UL Classified) at 64 Ib/sq Imbedded into one of the wet coats. Surfacing: — Mixture of "Pro -Tech Dry Mix 11" (40 lbs), Rohm & Haas MC -76 (1/2 gal), Rhone-Poulenc Colloid 622 (3/4 oz) and water http://database.ui.com/cgi-binfXWAemplate/LISEXT/1 FRAM E/showpage.h"I?name=TGFU.R 16029&ccnshorttife=Roofing+Systems&objid=1074352274&cfgi... 1/4 OMNI OND FOAM ROOFS AND WALL INSULATION PROPOSAL AND CONTRACT Contractor: FoamBond Corp A California Corporation Buyer: Premiere Construction lLeorl Job Address: 79600 Tom Fazio Lane North La Quinta, CA Telephone: 760-770-6922 1717 E. Vista Chino A7-835 Palm Springs, CA 92262 Toll Free 1-866-404-5440 Fax (760) 398-5440 Lie. 868171 C-39 FOAMBOND proposes to install polyurethane foam roofing system in accordance with the following scope of work at the above noted address on app. 12,896sq. feet. POLYURETHANE FOAM OVER EXISTING ROOF PREPARATION: 1. Clean surface of existing roof of all loose gravel, dirt and debris 2. Buckles, blisters, fish mouths and wrinkles shall be fastened or cut out 3. Replace damaged plywood and dry rot as needed at $1.85 a square foot 4. Cut back perimeter roof 6-8" from edge and drains l' radius down to substrate 5. Seal transition from Z -bar to parapet wall 6. Install all new 24 GA drip edge metal 7. Install blocks under all conduit and water lines 8. Extend roof jacks as required to accommodate new urethane foam roof 9. Prime entire roof deck at 1 gallon per 250 sq. ft. 10. Mask all areas not to receive the foam application (wall's, A/C's, furniture, etc.) URETHANE FOAM APPLICATION: 11. Spray/apply a minimum of 1" of 2.7 to 3.0 lbs. nominal density uniformly foam to entire roof deck and parapet walls, spray foam will be built up and sloped toward scupper/drains 12. Foam surface will be a smooth monolithic surface orange peel, free of tree bark, bumps, pinholes and ridges 13. Add foam build up in low areas to improve severely pond conditions 14. Grind foam at drains/runoff areas to promote proper drainage COATING APPLICATION: 15. Apply acrylic elastomeric caulking at roof penetrations as a secondary sealant to foam 16. Apply a high solids acrylic elastomeric gray basecoat at 1-1/2 gallons per 100 sq. ft. 17. Apply a high solids.acrylic elastomeric white topcoat at 1-1/2 gallons per 100 sq. ft 18. Add fire white ceramic roofing granules at 401b per 100 sq. feet on top of wet coating MAL WORK: 19. Remove all masking materials and overspray protection 20. Remove all job related trash from job sites and clean up after daily production 21. Perform a final job walk with the Owner or Owner's representative WARRANTY: 22. FoamBond warranties all labor and materials for a period of five years. The warranty is renewable at. the end of the term. Price and payment terms: 10% upon acceptance of contract and Balance due on job completion. TOTAL PRICE FOR THIS WORK AND MATERIALS IS: 551,360.00 0Am OND FOAM ROOFS wND WALL INSULATION Approved and Accepted by Owner: s C UL11 L Date