Loading...
9902-012 (SFD)LICENSED CONTRACTOR DECLARATION ,.I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # - Lic. Class Exp. Date 1706410 D/e� " :,, j 051�•1i2f D ej� r S _ �� Signature of Contract�or OWNER -BUILDER DECLARATION . I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). . ( ) I, as owner of the property, am exclusively'contracting with licensed contractors to construct the project (Sec.- 7044, Business & Professionals Code). () I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent'to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code,. for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance,'as required by Section 3700 of the Labor Code, for the performance of.the•work for which this permit is issueit.- 51y workers' compensation insurance carrier & policy no. are: Carrier ZENITH 01SURANCE Policy No. n4206250$ (This section need not be completed if the permit'valuation is for $100.00 or less). () I certify that in the performance of the work for which this permit is issued, I shall not employ any personin any manner so as to become subject to the workers' compensation laws of California, and agree that if (.should become subject,to the workers' compensation provisions of Section 3700 of the Labor Coe, Isfiallilforthwith comply'with those Prov ons. ate: n Applicant �i 1Rj. i iR Ak, It,, I t Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application.' 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant W any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such .permit, or, cessation of, work for 180 days will subject permit to cancellation. I certify that I have,read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspec� n purposes. t �! 1 /Suture (Owner/Agent),4 1Xvi _J.I� `t_t,%11+fa Datea— � to BUILDING PERMIT PERMITk DATE VALUATION LOT 99,,012 TRACT 9;73GfB 1 ? 27128 JOB SITE ry+ ADDRESS 79-€9E1.2 �'tii43FAZT..E)LAM $0110. APN 161-5324=1 OWNER CONTRACTOR / DESIGNER / ENGINEER T'URPFN CO2NS7RU(:170X 00. 1upP11d CON SrR (M -OX CO. . 78-120 CALLE Z71ADO #206 7E-120 CAL JP;' R91ADO #206 LAQUWjrA. CA 92253 LAQi77a°d"tA CA, 92253 (760)777.76111 CBVf 3751, USE OF PERMIT 0WCfJX J AW Y DW!?1'..IrW(J SFD - PERMIT DOES NOT INCLU69 BLOCK WALLS OR POOL CUSTOM CONSTRUCTION 51912.00 SF POR.0 HIPATIO 254.00 SIT C1ARA.OIZICARPORT (uF) 25,313:20: is MAT= COST Oy' coms:C7[3ucnoPl 409, 7�.2FD PFRMT FFIC SiTNB/i RY CONSTRUCTION FEE 101-000.416-000 $2,004,50 PLAN CHECK 199 101-000-439.318 $1,634.16 �l7 i" FEE DEPOSIT 101.000.439.318 411250.00 MECHANICAL 10.1-000-421-M $189.00 F, 1,fXTRfCP0, F JEE 101-000.420.000 $469.216 PLU.AADINCI IEE 101-0010-419-000 $3117.50 STRONG MOTION FEE • RESU) 101-000;.241-000 $9$ffl OPLAIDIN :l FEE 101-000-423-000, $20.00 w� DEVELOPER IMP.ACT.FEE"� .ART IN PUBLIC PLACES - RrSI'E- 701 -OW -25'5-000 $-M.34C "� SUB -TOTAL C01QS?RU(7] [0M AWD PLAN CW,,( . �"1a1d2.'i3 1XM PRE-11AID Y-TEZ TTO,_rAL 3'3MMJ.'I YKES DUE NOW �,W- 2.73 RECEIPT DATE B f DATE FINALED INSPECTOR INSPECTION RECORD OPERATION DATE 7F7INSPECTOR OPERATION DATE I INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck 0- - Exhaust Fans OX to Wrap F.A.U. Framing Compressor Insulation - Vents Fireplace P.L. W Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath - 2 R +a c Final Final POOLS - SPAS BLOCKWALL APPROVALS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final COMMENTS: Final�— Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) r! A - CITY OF LA QUINTA cFyoFo� BUI*NG & SAFETY DEPARTMENT ,`-777-7012 IN �JVTION REQUEST LINE �� • e ��� r,: ♦ 777-7153 Owner TURPIN CONSTRUCTION CO. T01PIN CONSTRUCTION CO. Contractor 9902-012 Permit Number POST ON JOB IN CONSPICUOUS PLACE (. INSPECTOR MUST SIGN ALL APPLICABLE SPACES gg - E SON PERMI E NOT INCLUDE BLOCK IWALLS OR POOL TYPE OF INSPECTION DATE INSP. i FOUNDATION & SETBACK r FOOTING STEEL I MAIN GROUND SYSTEM �. . GROUND PLUMBING PRE-GUNITE,. DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNED •. CONCRETE SLAB. JOISTS & GIRDERS' ELECTRICAL GROUND WORK DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNED: ROUGH ELECTRIC . ROUGH PLUMBING ROUGH GAS & GAS TEST HEATING&VENT -A/C FIREPLACE F.. . ROOF — C3 BOND BEAM r: O.K. TO WRAP GROUT ❑ 4' ❑ 8' FRAMING INSULATION { PRE -ROOF COVER NO WORK UNTIL ABOVE HAS BEEN SIGNED DRYWALL INTERIOR EXTERIOR LATH • -.=12- C ' GLI POOL PRE PLASTER POOL FENCE & GATE SEWER SEPTIC TANK FINALS ELECTRICAL /' • /. i Ll'� PLUMBING i FINAL GAS TEST HEATING - A/C HOUSE NUMBERS JOB COMPLETED TEMP POWER ABOVE APPROVALS DO` NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING QUA 0 4 P.O. BOX 1504 78-495 -WOE /viu 1 -Atte L1 SA_ LA QU NTACCAL FORNIIA 92253 Owner _ Mailing " Address r! i14_ L & City Zip Tel. Address S A ii Tel. State Lic. I City & Classif. Lic. # Arch., Engr., Designer Address LZ Tel. City Zips State ' I Z� 6G Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm�hgt 1 am licensed tinder provisions of Chapter 9 (commencing with Section 7000) of Division 3�of h�e Bu�siness�n d Professions Code, and my license Is in full force and effect. 'L24 SIGNATUREr ? r T DATE J OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to 4ts Issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions or the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code. or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by Any applicant for a permit subjects the applicant to a civil penalty of not more than rive hundred dollars ($500). 1' I, as owner of the property, or my employees with wages as their sole compensation, will do Ina work, and the structure is not intended or offered for sale. (Sec. 7044, Bulsness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does Such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I 1 1, as owner of the property, am exclusively contracting with licensed contractors to con• struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 1-1 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company (l Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed it rhe permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT., If, atter making this Certificate of Exemption you should become Subject t0 the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name- Lender's ame Lender's Address This is a building permit when property filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip Qq0,?, -a%ry APPLICATION ONLY ILDING: TYPE"CONST. OCC. GRP. '. Number tat Description L1J f Z `� -7 Project Description ZONE: BY: Minimum Setback Distances: Sq. Ft.�� , Z Size No. No. Dw. Stories Units New 0--- Add ❑ Alter ❑ Repair ❑ Demolition ❑ Side Street Set rmn Line } Side Setback fr Property FINAL DATE�EBR Issued by: Date Validated by: Estimated Valuation : /oO v �O PERMIT AMOUNT Plan Chk. Dep. I 0 op Plan Chk. Bal. Const. Mech. Electrical Plumbing S. M. 1. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Reaj. c Line `Otter Side Street Set rmn Line } Side Setback fr Property FINAL DATE�EBR Issued by: Date Validated by: Validation: Desert Sands Unified School District 47-950 Dune Palms Road Notice: La Quinta, CA 92253 Document Cannot Be Duplicated ' 760-771-8515 - CERTIFICATE OF COMPLIANCE Date . 6/9/00 APN # 761-532-008 No. 20534 Jurisdiction La Quinta Owner NameStll Turpin Permit # No. 79-062 Street Tom Fazio Larie South . Log # City La Quinta Zip 92253 Study Area Tract # Lot # Square Footage '5912 Type of Development Single Family Residence No. of Units 1 Comments At the present time, the Desert Sands Unified School District does not, collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 2:05 X 5,912 'or $112J 19.60 the property listed above and that building. . permits and/or Certificates of Occupancy for -this square footage in this proposed project may now_be'issued Fees Paid By 'CC/First CommunityBank-Bill Turpin TelepholneV 7.77-7611 Name on the check By Dr. Doris Wilson ?. Superintendent S Fee collected /exempted by Mary Ann L. Borja Payment Received $12,119.60 Check No. 095301 Signature V ' f,b. TICE: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified ve will begin to rin from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to lled them on the District('s)(s') behalf, whichever is earlier. . Collector: Attach a copy of county or city plan check application form to district copy for al) waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt ' Copy - Accounting THE UARRY, k T L A Q_U I N T A'- ' June 9, 2000 To whom it may concern:.,' The plans for 79062 Tom Fazio Lane South have been reviewed by the architectural review board at The Quarry and said plans have been approved. :i 9 ince r y, William Morrow ' President ' .F 7l r J. November 3, 2000 Mr. R. Kirk Kirkland City of La Quinta Building Department 78-495 Calle Tampico La Quinta, CA 92253 Re: Lot 12 at The Quarry; 79=062 Tom Fazio Lane_South Dear Kirk, Per our conversation in the field this morning I am making a formal request to eliminate the "weep screed" from Lot 12 at The Quarry. The house is constructed of Light Gage.Steel Framing and Red Iron Steel. Because there can be no dry -rot from moisture in the normal sense, I would like to substitute the following method in place of the weep screed. I propose we apply 24" of Mira-Dri water proof sheathing, 6" on concrete and 18" up on the steel stud walls. The application of Mira-Dri begins with a primer coat to the concrete and then the Mira-Dri sheet peels to allow self -sticking to the primer coat. I would like to put this material on the house and then request a re -inspection before we start to wrap. Of course, I will assume all responsibility for any problem that may occur from this variation of code requirements. 4Thankou for this consideration, UWilliam Turpin rpin Construction Co pany 78-120 Calle Estado, Suite 206, La Quinta, CA 92253 TEL: (760) 777-7611 FAX: (760) 777-7613 TITLE 24 REPORT r 1 , Title 24 Report fok: Turpin Residence Lot 12 La Q u i nta, CA 92253 s • Y i • Project Designer: Habitat 45-445 Portola, Unit 6B Palm'Desert, CA 92260 760-568-3670 Report Prepared By:* 9 Jim Urbano 'Mechanical Ventilation Systems 359 Marlboro'Way Banning, CA 92220 ` (760) 321-9216 r K i . Job Number: Date: 5/23/00 - The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has.approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 2.1 By EnergySoft Job Number: User Number: 4845 s ~ . n TABLE OF CONTENTS Cover Page .. 1 a - . Table of Contents - 2 Form CF -1R Certificateof Compliance .3 Form MF -1 R Mandatory Measures Checklist, 7 Form C -2R Computer Method Summary • 8 + , , ♦ , t 7 • f . r . r F • 3 f EnergyPro 2.1 By EnergySoft Job Number: User Number: 4845 TABLE OF CONTENTS Cover Page .. 1 a - . Table of Contents - 2 Form CF -1R Certificateof Compliance .3 Form MF -1 R Mandatory Measures Checklist, 7 Form C -2R Computer Method Summary • 8 + , , ♦ , t 7 • f . r . r F • 3 f EnergyPro 2.1 By EnergySoft Job Number: User Number: 4845 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Turpin Residence 5/23/00 Project Title Date Lot 12 La Quinta ' Location/Comments Type Project Address (attic, garage, typical, etc.) Building Permit # -Mechanical Ventilation Systems (760) 321-9216 Exterior Wall Wood 0.015 Plan Check Date Documentation Author I Telephone 0.756 Exposed'Slab w/R-0.0 Perimeter Insulation Computer Performance 15 0.756 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Screen Total Conditioned Floor Area: 5,912 f? , X❑ Total Conditioned Slab Area: 5,912 f? X❑ Building Type: (Northeast) (check one or more) . 0.45 X❑ Single Family Detached (SFD) ❑ Addition Alone Drapery ❑ Single Family Attached (SFA) ❑ Existing Building Screen ❑ Multi -Family ❑ Existing Plus Addition ' Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Power Wall 1 EPS Built Up Roof Slab On Grade Slab On Grade FENESTRATION 1qhar1inn r)Pvir_pc Type Const. Labeled Fenestration Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc.) Metal 0.076 Exterior Wall Wood 0.015 Exterior Roof n/a 0.756 Exposed'Slab w/R-0.0 Perimeter Insulation n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation 0.36 Drapery FENESTRATION 1qhar1inn r)Pvir_pc Type Orientation Area Labeled Fenestration Interior Exterior Overhang Side Fins SF U -Value SHGC roller blind, etc'. shadescreen, etc. Yes / No Yes / No Front (Northeast) 231.1 0.40 0.36 Drapery Bug Screen ❑ X❑ ❑ X❑ Front (Northeast) 292.8 0.45 0.36 Drapery ' Bug Screen ❑ X❑ ❑ o Front (Northeast) 96.0 0.49 0.36 Drapery Bug Screen • ❑ X❑ ❑ X❑ Left (Southeast) 246.1 0.40 0.36 Drapery Bug Screen ❑ x❑ ❑ X❑ Left (Southeast) 54.0 0.49 0.36 Drapery Bug Screen ❑ X❑ ❑ X❑ Rear (Southwest) 360.7 0.40 0.36 Drapery Bug Screen ❑ x❑ ❑ 0. Left (East) 79.5 0.40 0.36 Drapery Bug Screen ❑ k❑ ❑ X❑ Rear (South) 144.0 0.49 0.36 Drapery Bug Screen ❑ X❑ ❑ X❑ Rear (South) 23.4 0.40.0.36 Drapery Bug Screen ❑ x❑ ❑ X❑ Right (Northwest) 359.6 0.40 0.36 Drapery Bug Screen❑ X❑ ❑ X❑ Left (East) 75.2 0.45 0.36 Drapery Bug Screen❑ X❑ ❑ X❑ Left (East) 67.2 0.49 0.36 Drapery Bug Screen ❑ X❑ ❑ X❑ Run Initiation Time: 05/23/00 12:49:34 Run Code: 959111374 Ener Pro 2.1 By Ener Soft User Number: 4845 Job Number: Pa e:3 of 13 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Turpin Residence 5/23/00 Project Title Date Lot 12 La Quinta Project Address Building Permit # _Mechanical Ventilation Systems (760) 321-9216 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 5,912 f? Total Conditioned Slab Area: 5,9'12 ft2 Building Type: Orientation Area (check one or more) Interior X❑ Single Family Detached (SFD) ❑ Addition Alone ❑ Single Family Attached (SFA) ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deq Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) FENESTRATION Shadina Devices Type Orientation Area Labeled Fenestration Interior Exterior Overhang Side' Fins SF U -Value SHGC roller blind, etc. shadescreen, etc. Yes / No Yes / No Left (Southeast) 182.0 0.45 0.36 Drapery Bug Screen ❑ X❑ ❑ Rear (Southwest) 57.6 0.49 0.36 Drapery Bug Screen ❑ X❑ ❑ X❑ Skylight 36.0 0.68 0.55 None None ❑ X❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ El 1:1 R El El Run Initiation Time: 05/23100 12:49:34 Run Code: 959111374 Ener Pro 2.1 By Ener Soft User Number: 4845 I Job Number: Pa e:4 of 13 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Turpin Residence 5/23/00 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat ' Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnace 93% AFUE Ducts in Attic 42 Setback Undefined System Central Furnace 93% AFUE Ducts in Attic 42 Setback Undefined System Central Furnace 93% AFUE Ducts in Attic 4.2 Setback Undefined System Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic., etc.) R -Value Type Comments Split Air Conditioner 13.5 SEER Ducts in Attic 42 sethark I Indefined System Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback Undefined System Split Air Conditioner 13.5 SEER Ducts in Attic 4.2 Setback Undefined System WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater 'Distribution kin Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr. (gal) Efficiency Loss (%) R -Value A.O. SMITH FPS -40-224 Small Gas Pine Insulation 1 42,000 40 0.62 n/a n/a For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Jim Urbano Title/Firm: Habitat Title/Firm: Mechanical Ventilation Systems Address: 45-445 Portola, Unit 6B Address: 359 Marlboro Way Palm Desert, CA 92260 Banning, CA 92220 Telephone: 760-568-3670 Telephone: (760)'321-9216 Lic. #: (signature) (date) gn ure) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: 2.1 By EnergySoft User Number: 4845 Job Number: Page:5 of 13 1 Certificate of Compliance: Residential (Addendum) CF -1 R Turpin Residence 5/23/00 Project Title Date , Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 475 sqft Exposed Slab Floor, 4.00" thick at Master Bedroom HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1042 sqft Covered Slab Floor, 4.00" thick at Master Bedroom HIGH MASS Design(see C -2R) - Verify Thermal Mass: 241 sqft Exposed Slab Floor, 4.00" thick at Guest Bedroom HIGH MASS Design(see C -2R) - Verify Thermal Mass: 500 sqft Covered Slab Floor, 4.00" thick at Guest Bedroom HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2443 sqft Exposed Slab Floor, 4.00" thick at Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1211 sqft Covered Slab Floor, 4.00" thick at Living HERS Required Verification ` ' ,. These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the tieia veriticauon and diagnostic testing of these measures on a torm cF-sR. plan Field i . Run Initiation Time: 05/23/00 12:49:34 Run Code: 959111374 EnergyPro 2.1 By EnergySoft User Number: 4845 Job Number: Page:6 of 13 Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component specifications. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMEN Building Envelope Measures *§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. ❑ 150(b): Loose fill insulation manufacturer's labeled R -value. *§ 150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value (does not apply to exterior mass walls). ❑X *§ 150(d): Minimum R-13 raised floor insulation in wood framed floors. ❑ § 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 perm/inch. ❑X §118: Insulation specified or installed meets quality standards. Indicate type and form. ❑X §116-17` Fenestration Products, Exterior Doors and Infiltration/Exfiiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑ §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ❑ §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA. §150(1): Setback thermostat on all applicable heating and/or cooling systems. n§1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation, piping between heat source and tank insulated. 3.Insutation on the first 5' of pipes closest to water heater tank, non -recirculating systems (R4 or greater), buried or exposed piping in recirculating sections of hot water systems, cooling system piping below 55 deg F. X1 *§150(m): Ducts and Fans 1: All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBO 1997 UMC sections 601 603; ducts insulated to a minimum installed R4.2 or ducts enclosed entirely within conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct closure system that meets the applicable requirements of UL181, UL181 S, or UL181 B and other applicable specified test for longevity given in 150(m). 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems servng conditioned space have either automatic or readily accessible, manually operated dampers. ❑ §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no pilot or electric resistance heating. 2. System is installed with at least 36" of pipe between filter and heater, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch; X§115: Central Furnaces, pool heaters, spa heaters or household cooking appliances have no constant pilot light. Lighting Measures X❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. X❑ 150(k)2: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in 150(k)2.; and recessed ceiling are IC (insulation cover) approved. JEnergyPro 2.1 By EnergySoft User Number: 4845 Job Number: Page:7 of 13 Computer Method Summary (Part 1 of 3) C-2R Ti irnin Residence Project Title 5/23/00 Date Lot 12 La Qi flnta Project Address Building Permit # Ventilation Svstems (760) 321-9216 _Mechanical Documentation Author Telephone . Plan Check/Date Computer Performance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.86 3.36 1.50 Space Cooling 39.01 ' 39.36 -0.35 Domestic Hot Water 4.82 3.87 0.95 Totals . 48.69 46.59 2.10 ENERAL INFORMATION Conditioned Floor Area: 5,912 Floor Construction Type: X❑ Slab Floor Building Type: Single Fam Detached Raised Floor Building Front Orientation: (North) 0 deg Number of Dwelling Units: 1.00 Total Conditioned Volume: 59,120 Number of Stories: 1 Slab Floor Area: 5,912 BUILDING ZONE INFORMATION # of -Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. 'Area Undefined System 1 517 151 170 096 CnnditinnPri Sethack 2 n/a Undefined System 741 741 013 Conditioned Sethack 2 n/a Undefined System 3 654 36 54 062 Conditioned Sethack n/a OPAQUE SURFACES Solar Act. Gains Type Area U -Val. Azm. Tilt �Y / N Wall 183 0.076 �5— _ 90 Ipl U yy)_ 285 0 076 135 g0 ® ❑ Wall 501 0.076 225 g.0_ ® ❑ Roof 1,517 0.015 _Q 0 ❑ Wall 360 0.076 45 go ❑ Wall 61 0.076 _9.0 gn ❑ Wall 397 0.076 180 90 ❑ Wall 252 0.076 315 90 ❑ Roof 741 0.015 0 o IN ❑ Wall 37 0.076 45 gn ® ❑ Wall 221 0.076 90 go ® ❑ Wall 133 0.076 135 qQ ® ❑ wall 244 0.076 225 go ® ❑ Wall 349 0.076 ' 315 g0_ ® ❑ Roof 3,618 0 015 _Q n IN ❑ Form 3 Reference Location / Comments Zone 1 7nne 1 7nne 1 7nne 1 Zone 2 7nne 2 EnergyPro 2.1 By EnergySoft User Number: 4845 Job Number: I Paae:8 of 13 1 Computer Method Summary (Part 2 of 3) C -2R Turpin Residence 5/23/00 Project Title Date FENESTRATION SURFACES U -Value Act. Glazing Type Location/ # Type Area SHGC Azm. Tilt Comments -1- Window Front (Northeast) _35.1. _0.400 0.36 45_ -9.0. Reet,mac. #530 Zone 1 2 Window Front (Northeast) 77.4 0.450 0.36 45 90 Fleetwood #3033 Zone 1 3 Window Front (Northeast) 28.8 0.400 0.36 45 90 Fleetwood #530 Zone 1 4 Window Front (Northeast) 96.0 0.490 0.36 45 90 Fleetwood #3300 Zone 1 5 Window Left (Southeast) 102.3 0.400 0.36 135 90 Fleetwood #530 Zone 1 6 Window Left (Southeast) 9.0 0.400 0.36 135 90 Fleetwood #530 Zone 1 7 Window Left (Southeast) 9.0 0.400 0.36 135 90 Fleetwood #530 Zone 1 8 Window Left (Southeast) 9.0 0.400 0.36 135 90 Fleetwood #530 Zone 1 6 Window Left (Southeast) 54.0 0.490 0.36 135 90 Fleetwood #3300 Zone 1 1Q Window Left (Southeast) 12.0 0.400 0.36 135 90 Fleetwood #530 Zone 1 1 Window Rear (Southwest) 48.0 0.400 0.36 225 90 Fleetwood #530 Zone 1 12 Window Rear (Southwest) 16.0 0.400 0.36 225 90 Fleetwood #530 Zone 1 13 Windo�nr�Etear fSo�tbwest) -9 6 0-400 0.36 _225 -20 Flaebw-od_#530 Zone 1 14 Window Rear (Southwest) 16.0 0.400 0.36 225 90 Fleetwood #530 Zone 1 15 Window Rear (Southwest) 36.0 0.400 0.36 225 90 Fleetwood #530 Zone 1 16 Window Rear (Southwest) 39.2 0.400 0.36 225 90 Fleetwood #530 Zone 1 17 Window Rear (Southwest) 17.8 0.400 0.36 225 90 Fleetwood #530 Zone 1 18 Window Left (East) 23.4 0.400 0.36 90 90 Fleetwood #530 Zone 2 JR Window Rear (South) 72.0 0.490 0.36 180 90 Fleetwood #3300 Zone 2 20 Window Rear (South) 72.0 0.490 0.36 180 90 Fleetwood #3300 Zone 2 21 Window Rear (South) 23.4 0.400 0.36 180 90 Fleetwood #530 Zone 2 22 Window Right (Northwest) 7.2 0.400 0.36 315 90 Fleetwood #530 Zone 2 23 Window Right (Northwest) 9.2 0.400 0.36 315 90 Fleetwood #530 Zone 2 24 Window Right (Northwest) 16.0 0.400 0.36 315 90 Fleetwood #530 Zone 2 25 Window Right (Northwest) 16.0 0.400 0.36 315 90 Fleetwood #530 Zone 2 26 Window Front (Northeast) 28.0 0.400 0.36 45 90 Fleetwood #530 Zone 3 27 Window Front, (Northeast) 64.0 0.450 0.36 45 90 Fleetwood #3033 Zone 3 28 Window Front (Northeast) 16.0 0.400 0.36 45 90 Fleetwood #530 Zone 3 29 Window Front (Northeast) 151.4 0.450 0.36 45 90 Fleetwood #3033 Zone 3 INTERIOR AND EXTERIOR SHADING # Interior Shade Type SHGC Exterior Shade Type Window Overhang Left Fin Right Fin SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Drapery 0.68 Bug Screen 0.76 2 Drapery 0.68 Bug Screen 0.76 3 QLap_yr 0.68 Bug Screen - - - - - - - - - - - - 0.76 4 Drapery 0.68 Bug Screen 0.76 5 Drapery 0.68 Bug Screen - - - - - - - - - 0.76 6 Drapery 0.68 Bug Screen 0.76 7 Drape 0.68 Bug Screen 0.76 8 Drapery - 0.68 Bug Screen 0.76 9 Drapery - 0.68 Bug Screen - - - - - - - - - - - - 0.76 10 DrD apery 0.68 Bug Screen - - - - - - - - - - - - 0.76 11 Drapery - 0.68 Bug Screen - - - - - - - - - - - - 0.76 12 Drapery 0.68 Bug Screen - - - - - - - - - - - - 0.76 13 Drapery 0.68 Bug Screen 0.76 T4- 14 Drapery 0.68 Bug Screen - - - - - - - - - - 0.76 15 Drapery 0.68 Bug Screen 0.76 16 Drapery 0.68 Bug Screen 0.76 17 qrapey Draper 0.68 Bug Screen 0.76 18 Drapery - 0.68 Bug Screen 0.76 19 Drapery 0.68 Bug Screen - - - - - - - - - - - - 0.76 20 Drapery 0.68 u Screen 0.76 21 Drapery 0.68 Bug Screen 0.76 22 Drapery 0.68 Bug Screen 0.76 23 Drapery 0.68 Bug Screen - - - - - 0.76 24 Drapery 0.68 Bug Screen 0.76 25 Drapery 0.68 Bug Screen - - - - - - - - - - - - 0.76 26 Drapery 0.68 Bug Screen 0.76 27 Drapery 0.68 Bug Screen - - - - - - - - - - - - 0.76 28 Drapery 0.68 Bug Screen 0.76 29 Drapery 0.68 Bug Screen 0.76 EnergyPro 2.1 By EnergySoft User Number: 4845 Job Number: Page:9 of 13 1 Computer Method Summary (Part 2 of 3) C -2R Turpin Residence 5/23/00 Project Title Date FENESTRATION SURFACES # Type Area LI -Value SHGC Act. Azm. Glazing Type Tilt Location/ Comments 30. Window__aopt (Noy hLeast) 123.2 Q.4D9_ _0 36_ 45_ _90. Fleetwa d #530 Zone 3 31 Window Left (East) 6.5 0.400 0.36 90 90 Fleetwood #530 Zone 3 32 Window Left (East) 28.0 0.400 0.36 90 90 Fleetwood #530 Zone 3 33 Window Left (East) 75.2 0.450 0.36 90 90 Fleetwood #3033 Zone 3 34 Window Left (East) 21.6 0.400 0.36 90 90 Fleetwood #530 Zone 3 35 Window Left (East)_ 67.2 0.490 0.36 90 90 Fleetwood #3300 Zone 3 ira Window Left (Southeast) 48.0 0.450 0.36 135 90 Fleetwood #3033 Zone 3 37 Window Left (Southeast) 34.8 0.400 0.36 135 90 Fleetwood #530 Zone 3 3-3 Window Left (Southeast) 48.0 0.450 0.36 135 90 Fleetwood #3033 Zone 3 39 Window Left (Southeast) 86.0 0.450 0.36 135 90 Fleetwood #3033 Zone 3 4Q Window Left (Southeast) 70.0 0.400 0.36 135 90 Fleetwood #530 Zone 3 41 Window Rear (Southwest) 33.6 0.400 0.36 225 90 Fleetwood #530 Zone 3 42 Wlndo�er Rear _(Southwest) 57.6 0.490 0.,.3.6 _225-- gQ F1eet1tLood9E331Z0 Zone 3 43 Window Rear (Southwest) 37.8 0.400 0.36 225 90 Fleetwood #530 Zone 3 44 Window Rear (Southwest) 30.4 0.400 0.36 225 90 Fleetwood #530 Zone 3 45 Window Rear (Southwest) 29.8 0.400 0.36 225 90 Fleetwood #530 Zone 3 46 Window Rear (Southwest) 19.5 0.400 0.36 225 90 Fleetwood #530 Zone 3 47 Window. Rear (Southwest) 9.0 0.400 0.36 225 90 Fleetwood #530 Zone 3 4 $ Window Rear (Southwest) 9.0 0 .400 0.36 225 90 Fleetwood #530 Zone 3 49 Window Rear (Southwest) 9.0 0.400 0.36 225 90 Fleetwood #530 Zone 3 50 Window Right (Northwest) 108.9 0.400 0.36 315 90 Fleetwood #530 Zone 3 51 Window Right (Northwest) 75.8 0.400 0.36 315 90 Fleetwood #530 Zone 3 52 Window Right (Northwest) 49.7 0.400 0.36 315 90 Fleetwood #530 Zone 3 53 Window Right (Northwest) 24.0 0.400 0.36 315 90 Fleetwood #530 Zone 3 54 Window Right (Northwest) 15.0 0.400 0.36 315 90 Fleetwood #530 Zone 3 55 Window Right (Northwest) 37.8 0.400 0.36 315 90 Fleetwood #530 Zone 3 56 Skylight Front (North) 36.0 0.680 0.55 0 0 Fleetwood #530 Zone 3 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Interior Shade Type SHGC Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hqt. Dist. Len. Hat. 30 Drapery 0.68 Bug Screen 0.76 31 Drapery 0.68 Buq Screen 0.76 32 DrD apery 0.68 Bug Screen 0.76 33 Drape 0.68 Bug Screen 0.76 - 34 Drapery 0.68 Bug Screen - - - - - 0.76 35 Drapery 0.68 Bug Screen 0.76 36 Drapery 0.68 Bug Screen 0.76 37 Drapery 0.68 Bug Screen 0.76 38 DrD apeery 0.68 Bug Screen 0.76 39 Drapery 0.68 Bug Screen 0.76 40 Drapery 0.68 Bug Screen 0.76 41 Drapery 0.68 Bug Screen 0.76 42 Drapery 0.68 Bug Screen 0.76 43 Drapery 0.68 Bug Screen 0.76 44 Drapery 0.68 Bug Screen 0.76 45 Drapery 0.68 Bug Screen 0.76 46 Drapery 0.68 Bug Screen 0.76 47 Drapery 0.68 Bug Screen 0.76 48 Drapery 0.68 Bug Screen 0.76 49 Drapery 0.68 Bug Screen 0.76 50 Drapery 0.68 Bug Screen 0.76 51 Drape 0.68 Bug Screen 0.76 52 Drapery 0.68 Bug Screen - - - - - - 0.76 53 Drapery 0.68 Bug Screen 0.76 54 Drapery 0.68 Bug Screen 0.76 55 Drapery 0.68 Bug Screen 0.76 56 None 1.00 None 1.00 EnergyPro 2.1 By EnergySoft User Number: 4845 Job Number: Paae:10 of 13 1 Computer Method Summary F2 Factor (Part 3 Of 3) C -2R Location / Comments Slab Perimeter - 88 0.76 Turpin Residence Zone 1 Slab Perimeter 130 5/23/00 Project Title Zone 1 Slab Perimeter 63 Date THERMAL MASS FOR HIGH MASS DESIGN Zone 2 Slab Perimeter 90 0_76 Area Thick. Heat Zone 2 Inside Location Type (sfl (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete Heavyweight 475 4_00 _28. 0_98 n/a 0 Zone 1 / Slab on Grade Concrete, Heavyweight 1,042 4_00 28 0_98 n/a 2 Zone 1 / Slab on Grade Concrete. HeayMight 241 4_00 28 0_98 n/a 0 Zone 2 / Slab on Grade Concrete, Heavyweight 500 4_00 28 0_98 n/a 2 Zone 2 / Slab on Grade Concrete. ea eight 2,443 4_00 28 0_98 n/a 0 Zone 3 / Slab on Grade PERIMETER LOSSES Type Length F2 Factor Insulation R -Val. Depth Location / Comments Slab Perimeter - 88 0.76 0.0 0 Zone 1 Slab Perimeter 130 0_76 0.0 0 Zone 1 Slab Perimeter 63 0.76 0.0 0 Zone 2 Slab Perimeter 90 0_76 0.0 0 Zone 2 Slab Perimeter 198 0676 0.0 0 Zone 3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 93%AFUE Ducts in Attic 44"2 Setback Undefined System Cental Furnace 93%AFUE Ducts in Attic 4.2 Setback Undefined System Central Furnace 93%AFUE Ducts in Attic 4.2 Setback Undefined System Hydronic Piping Pipe . Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS I Ratedl Tank Energy Facts 1 Tank Insul. Water, Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (al) Efficiency Loss (%) Ext. A.O. SMITH FPS -40-224 Small Gas Pipe Insulation 1 42.000 40 0.62 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. :1:hT t:11.V r Run Initiation Time: 05/23/00 12:49:34 Run Code: 959111374 EnergyPro 2.1 By EnergySoft User Number: 4845 Job Number: Page: 11 of 13 Cooling Equipment Minimum Duct - Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value - Type Comments Split Air Conditioner 13.5 SEER Ducts in Attic 4.2 Setback Undefined System Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback Undefined System Split Air Conditioner 13.5 SEER Ducts in Attic 4.2 Setback Undefined System WATER HEATING SYSTEMS I Ratedl Tank Energy Facts 1 Tank Insul. Water, Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (al) Efficiency Loss (%) Ext. A.O. SMITH FPS -40-224 Small Gas Pipe Insulation 1 42.000 40 0.62 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. :1:hT t:11.V r Run Initiation Time: 05/23/00 12:49:34 Run Code: 959111374 EnergyPro 2.1 By EnergySoft User Number: 4845 Job Number: Page: 11 of 13 User Number: 4845 Job Number: Page:! 2 of 13 i K Computer Method -Summary -(Part 3 of 3) C -2R Turpin Residence 5/23/00 Project Title Date - THERMAL MASS FOR HIGH MASS DESIGN ' Area Thick. Heat Inside Location Type (sf) ` (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete Heavyweight 1 211 4.00 9A 0 9g n1a 2 Zone 3 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 140 0_76 0.0 0 Zone 3 - HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Hydronic Piping pipe Pipe Insul. - System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner; • Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. - User Number: 4845 Job Number: Page:! 2 of 13 Comouter Method Summary (Addendum) C2 -R Turpin Residence 5/23/00 Project Title Date Special Features and Modeling Assumptions ,. The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan • Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 475 sqft Exposed Slab Floor, 4.00" thick at Master Bedroom HIGH MASS Design(see C -21R) - Verify Thermal Mass: 1042 sqft Covered Slab Floor, 4.00" thick at Master Bedroom HIGH MASS Design(see C -21R) - Verify Thermal Mass: 241 sqft Exposed Slab Floor, 4.00" thick at Guest Bedroom HIGH MASS Design(see C -2R) - Verify Thermal Mass: 500 sqft Covered Slab Floor, 4.00" thick at Guest Bedroom HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2443 sqft Exposed Slab Floor, 4.00" thick at Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1211 sqft Covered Slab Floor, 4.00" thick at Living HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -611. Plan Field Run Initiation Time: 05/23/00 12:49:34 - Run Code: 959111374 EnergyPro 2.1 By EnergySoft User Number: 4845 Job Number: I Pagel3 of 13