Loading...
9510-047 (SFD)i r¢, LICENSED CONTRACTOR DECLARATION x I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my "license is in full force and effect. 70641.0 8 5(31/97 License # Lic. Class Exp. Date Date Signatureof Contractor ~ OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the, following "reason: () I; as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). () I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section , B&P.C. for this reason Date Signature of Owner WORKER'S. COMPENSATION DECLARATION I•hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier Policy No. (This section neeCl oot pecompleted if the permit valuatio0 i.'bjo ,$1:W.00 or less). () I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose be this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application agrees to, & shall, indemnify & hold harmless the City of Indian Wells, its officers, agents and employees,, 2. Any permit issued as a result of this application becomes null and void -if work is not commenced within 180 days from date of issuance of syc permit, or cessation of work for 180 days will subject permit to cancellatio (�' I certify that I have read this application and state that the above inform' /'on ip correct. I agree to_comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes: t y Signature (Owner/Agent) Dats ALCM' v BUILDING PERMIT PERMITya�1fA -DATE 1111141%0' VALUATION .5 'bii..11. -.A43 LOT TRACT zt,=-O'f Gi JOB SITE ADDRESS 79-484) TOM FAZIO i,AVE NWIVIR APN V OWNER CONTRACTOR , 17_JR:PI1d CONS'ITt.UCIION CO. LA QtJINTA GOLF PROPE 549361 91-10M, CREEK 75 -UO TONT FAZIO LANE NORTH LA QUINT CA 92253 LA QU7NTA CA 92253 (61.9)777-7611 C001 3751 (C-19)777-1100 DESIGNER/ENGINEER HABITAT 74105 i'VIOCKiNGIBIRRD USE OF PERMIT! NGLL' YAN.IiLY OWtUTLINU MOIAN WELLS. CA 92210 SL#2WR I'146 QUA3tKY PEWIT DOES NOT INIC1,IME BLOCK WALLS OR POOL. FEE DESCRIPTION FEES Ctisrom'CO NSTRUC",1'1C).N' 2,:44fi.U0.LF GAP,A(WJCARPOWf 67COO SF PORCK(.PA'IIO 644.00 SF ESUMATED COST OF CONSTRUCTION 220,148.20 PERMIT VCE SSU? Y f FEF, DEPOSIT 42,50.00 PLAN CRW- rtes 101.000-439-318 SM321 CONS 101-000418-000 $L063.33 9F. CBANIC'•AL FFA 101-Oi:10-421.000 $102.50 FfY,CTRICAL FEE 101-400420-000 $175.13 PLUNAWmiG VEE 1014000.419-000 $211.50 SIX)NG b O i tON 1U -12ESID 100-000-241»M $^2.41 GRADING I',13 101 -000 -423 -ON 520.00 INFIWIN IC-17URE FE!l 225.000-443.342 1$3,760,6: ART IN" PUBLIC PLACES -1ZE.Sir, 70:1-000-255-000 3308.3; SIM -TOT AL CONS' RJ JCT ION .1'* 0 PLAN CHECK.- Op7,53'7. 79 n LESS PRE -PAID PEES 4250.00 TOT'AI P. RMff FEES. 1)l:II!,NOW S7; 87.79 T 3 0 1995 i TCW, PROJECT PE tl M(f .(«11ES 7 sm /9 RECEIPT DATE BY DATE RNALED INSPECTOR INSPECTION RECORD OPERATION DATE TINSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final POOLS - SPAS BLOCKWALL APPROVALS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G IF.l. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) I `o _ s CITY OF LA QtUINTA BUILDING & SAFETY DEPARTMENT VO�Oj 777-7012 }x INSPECTION REQUEST LINE 777-7153 Off' QUINTA GOLF PROPERTIES j'Owner TURPIN CONSTRUCTION Contractor .9510-047 Permit Number POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES I 79430 TOM FAZIO LANE NORTH i JOB ADDRESS SFD PERMIT DOES NOT INCLUDE BLOCK WALL OR POOL. TYPE OF INSPECTION DATE INSP. FOUNDATION & SETBACK j FOOTING STEEL — k MAIN GROUND SYSTEM GROUND PLUMBING PRE-GUNITE . DO NOT POUR CONCRETE UNTIL ALL ABO HA EENIGNED CONCRETE SLAB — JOISTS & GIRDERS ELECTRICAL GROUND WORK DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNED ROUGH ELECTRIC ROUGH PLUMBING 'ROUGH GAS & GAS TEST HEATING & VENT - A/C FIREPLACE ROOF BOND BEAM O.K. TO WRAP FRAMING COVER NO WORK UNTIL ABOVE HAS BEEN SIGNED DRYWALL INTERIOR EXTERIOR LATH POOL PRE PLASTER POOL FENCE & GATE SEWER SEPTIC TANK FINALS ELECTRICAL " P[,, MBING. i FINAL GAS TEST i HEATING - A/C { ..HOUSE NUMBERS JOB COMPLETED TEMP POWER u t s TITLE 24 REPORT FOR: LOT 72 THE QUARRY LA QUINTA: CA. PROJECT DESIGNER: HABITAT 74105 MOCKINGBIRD TRAIL. INDIAN JELLS, CA. (619) 568-3670 REPORT PREPARED BY: R.Krown. CEA R92-93 204, KROWN MECHANICAL. DESIGN P.O.BM( 1761 LA QUINTA, CA 92253 (619) 773-2623 Job Number: 95052-3 Date: 7/19/1995 Certified BROW Aselle Aia�d F. !lain 'O'f /;Z s� rr rr CABEC. calftff of building En*W ConsA" The COMPLY 24 computer program has been used to perform the. calculations s summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential Building Energy Efficiency Standards. This program developed by Gabel Dodd Associates (510) 428-0803. Table Of- Contents .-for, Title 24 Report C.............Paae ................:............ 1 Table of Contents ................................................... 2 Form CF -IR -Certificate of Compliance:: Residential ................... 31 Form MF -.1R Mandatory Measures Checklist: Residential ................ 5 Form C -2R Computer Method Summary .................................... 7 HVAC Zone & Space Loads Summary ...................................... 10 Form CF -6R Installation Certificate. Residential .................... 18 CERTIFICATE OF COMPLIANCE: Residential (part 1 of 2) CF -1R page 3 of 18 Project Name: LOT 72 ;Date: 7/19/1995 Address: THE QUARRY LA QUINTA, CA. ;Building Permit No Designer: HABITAT ;Checked by / Date Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366 ----------------------------------------------- --------------------------- GENERAL INFORMATION Compliance Method: COMPLY 24 version 4.11 Climate Zone: 15 Conditioned Floor Area: 2546 sqft Building Type: Single Fam Det:. Building Front Orientation: 240 deg (SW) Number of Dwelling Units: 1 Floor Construction Type: Slab on Grade BUILDING SHELL_ INSULATION Component U -Value Location/Comments R-21 Wall (W21.2x6.16) 0.060 LIV/DIN/KIT Solid Wood Door 0.387 LIV/DIN/KIT R-21 Wall (W21.2x6.16) 0.060 GUEST I R-21 Partition (2x6,.16) 0.057 GUEST :.1. R•-21 Wall (W21.2x6.16) 0.060 MASTER SUITE R-21 Partition (2x6.16) 0.057 MASTER, SUITE Built--up/R-38/Gypboard 0.030 LIV/DIN/KIT Tile/R-38/Gypbd 0.029 LIV/DIN/KIT Built-up/R-38/Gypboard 0.030 GUEST 1 Built-•up/R-38/Gypboard 0.030 MASTER SUITE: Slab Perimeter w/R-0.0 0.720 LIV/DIN/KIT Slab Perimeter w/R.-0.0 0.900 LIV/DIN/KIT Slab Perimeter w/R-0.0 0.720 GUEST 1 Slab Perimeter w/R-0.0 0.900 GUEST I Slab Perimeter w/R-0.0 0.720 MASTER SUITE Slab Perimeter w/R-0.0 0.900 DIASTER SUITE FENESTRATION Shading_ Devices Frame Orient. Area U -Val Type Interior Exterior OH SF Type --------- ------ ----- ------------------------------------ -- -- ----- Left (N) 53.1 0..52 Double Std Drape Standard Bug Scr N N Vinyl Back (NE) 96.0 0.50 Double Std Drape Standard Bug Scr N N Vinyl Back (E) 76.0 0.52 Double Std Drape Standard Bug ScrN N Vinyl Right (SE) 84.0 0.52 Double Std Drape Standard Bug Scr N N Vinyl Right. (S) 94.0 0.52 Double Std Drape Standard Bug Scr N N Vinyl Right (S) 64.0 0.52 Double Std Drape Standard Bug Scr Y N Vinyl Front (SW) 76.0 0.50 Double Std Drape Standard Bug Scr N N Vinyl Front (W) 128.0 0.50 Double Std Drape Standard Bug Scr Y N Vinyl Front (W) 3S.0 0.52 Double Std Drape Standard Bug Scr N N Vinyl Front (W) 32.0 0,52 Double Std Drape Standard Bug Scr Y N Vinyl Front (W) 24.0 0.57 Double Std Drape Standard Bug Scr N N None THERMAL MASS Area Thick Type Covering (sf) (in) Location/Description ----------------------------- ----- ----- ------------------------------ Concrete, Heavyweight Covered 700 3.50 Slab on Grade Concrete, Heavyweight Exposed 768 3.50 Slab on Grade Concrete, Heavyweight Covered 340 3.50 Slab on Grade: Concrete, Heavyweight Exposed 25 3.50 Slab on Grade Concrete, Heavyweight Covered 593 3.50 Slab on Grade Concrete. Heavyweight Exposed 120 3.50 Slab on Grade CERT.IFICATE OF COMPLIANCE: Residential (part 2 of 2 ) CF -1R page 4 of 18 --------------------------------------------------------------------------- Project Name: LOT 72 ;Date: 7/19/1995 Documentation: --------------------------------------------------------------------------- KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366 HVAC SYSTEMS Minimum Distrib Type System Type Efficiency and Location Furnace 0.801 AFUE Ducts in Attic SpltAirCondl2.150 SEER Ducts in Attic Furnace 0.801 AFUE Ducts in Attic SpltAirCondl2.050 SEER Ducts in Attic Duct TStat RVal Type Location/Comments 4.2 SetBck FAU/CU/CO.IL 1 4.2 SetBck 4.2 SetBck FAU/CU/COIL 2 4.2 SetBck Water No. Tank Ext. WATER. HEATING SYSTEMS Heater in Energy Size Insul System Name Distribution Type Type Sys Factor (gal) R -Val ----------------------- -------------- - ---------- --- ------ ----- ----- AMERICAN APP G52 -50T38- Pipe Insulation Storuas 1 0.60 50.0 0.0 AMERICAN APP G52-5OT38-- Recirc-Time&Temp StorGas 1 0.60 50.0 0.0 AFUE WATER HEATER EQUIPMENT DETAIL_ /R,ec Rated Stdby Tank Pilot System Name System Type Eff Input Loss R -Val Light ----------------------- ----------- ---- ----- ----- ----- ------ AMERICAN APP G52 -50T38- DomesticHW 0.760 38000 0.000 16.0 0 AMERICAN APP G.52 --50T38- DomesticHW 0.760 38000 0.000 16.0 0 SPECIAL FEATURES/REMARKS V.A.V.TO GUEST I A Zonally Controlled HVAC System which meets CEC criteria has been assumed COMPLIANCE STATEMENT This Certificate of Compliance lists the building features and performance specifications needed to comply with Title .24, Parts 1 & 6 of the Califor- nia Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section DESIGNER or OWNER (Per Business & Professions HABITAT 74105 MOCKINGBIRD TRAIL INDIAN WELLS, CA. (619) 568-3670 Lic #: (signature) ENFORCEMENT Name: Title: Agency: Telephone:_ AGENCY Code) (date) DOCUMENTATION AUTHOR R.Krown, CEA R92-93 204 KROWN MECHANICAL_ DESIGN P.O.BOX 176.1 LA QUINTA, CA 92253 (619) 773-2623 i 711 7/f ignature) (date) (signature/stamp) (date) MANDATORY MEASURES CHECKLIST (part 1 of 2 ) MF --IR page 5 of 18 --------------------------------------------------------------------------- Project Mame: LOT 72 ;Date: 7;'190995 Documentation: KP.OWN MECHANICAL. DESIGN ;COMPLY 24 User 2366 --------------------------------------------------------------------------- NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Enforcement o Sec. ISM): Minimum R-19 ceiling insulation. o Sec. 1.50(b): Loose fill insulation manufacturers labeled P. -Value. o Sec. 150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). o Sec. ISO(d): Minimum R-13 raised floor insulation in framed floors: Minimum R-8 in concrete raised floors. o Sec. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. o Sec. 118: Insulation specified or installed meets California Energy Commission quality standards. Indicate Type & form. o Sec. 116-117: Fenestration Products, Ext Doors & Infil/Exfil Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label w/certified U -Value c. Exterior doors and windows weatherstripped; all :joints and penetrations caulked and sealed. o Sec. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. o Sec. 150(f): Special infiltration barrier installed to .comply with Sec. .151 meets Commission quality standards. o Sec. 150(e): Installation of Fireplaces. Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST (part; 2 of 2 ) MF -1R page 6 of 18 ----------------------------------------- Project. Name: LOT 72 ;Date: 7/19/1995 Documentation: YP.OWN MECHANICAL DESIGN ;COMPLY 24 User 2366 ----------------------------------------------------------------------------- SPACE CONDITIONING. WATER HEATING AND PLUMBING SYSTEM MEASURES Enforcement o Sec. 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. o Sec. 150(1): Setback thermostat on all applicable heating systems. o Sec. 1. 2. 3. 4. S. o Sec. 1. 2. 3. 150(.1): Pipe and Tank Insulation Indirect hot water tanks (eg unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R=16 or (:ireater). First 5 feet of pipes closest to water heater tank, non -recirculation systems, insulated (P,-4 or greater. All buried or exposed pipina insulated in recirculation sections of hot water system. Cooling system piping below 55 F insulated. Piping insulated between heatina source and indirect hot water tank. _ 150(m) Ducts and Fans Ducts constructed, installed and sealed to comply with UMC Sections 1002 and .1004: ducats insulated to a minimum R-4.2 or ducts enclosed entirely within conditioned space. Exhaust systems have backdraft or automatic dampers. Gravity ventilating systems serving conditioned space have either automatic or readily accessible manually operated dampers. _ o Sec. 114:Pool and Spa Heating Systems and Equipment I. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric: resistance heating and no pilot light. 2. System is installed with: a. At least 36'' pipe between -filter and heater t'or future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. o Sec. 1].5: Gas-fired central furnace, pool heater, spa heater or household cookina appliance have no continuously burning pilot light. (.Excepti.on: Non -electrical cookinc.i appliance with pilot < 150 Btuh) LIGHTING MEASURES o Sec. 150(k): Liahtina - 40 lumens/watt or areater for general liahting in kitchens and rooms with water closets: and recessed ceiling fixtures IC (insulation cover) approved. COMPUTER METHOD SUMMARY .104 C -2P, page 7 of 18 --------------------------------------------------------------------------- Project. Name: LOT 72 Yes ;Date: 7/19/1995 Documentation: KROWN MECHANICAL_ DESIGN .--------------------------------------------------------------------------- LIV/GIN/KIT ;COMPLY 24 User 2366 0.387 Standard Proposed Compliance Source Energy Use (KBtu/sf-y�) Design Design Margin Space Heating 3.99 4.10 -0.10 Space Cooling 30.22 27.81 2.4.1 Domestic Hot Water 10.26 11.87 -------- -1.61 ---------- TOTALS -------- 44.47 43.78 0.69 *** BUILDING COMPLIES *** GENERAL. INFORMATION Compliance Method: Climate Zone. Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: Floor Construction Type: Total Conditioned Volume: Conditioned Footprint Area: Ground Floor Area: BUILDING ZONE INFORMATION COMPLY 24 version 4.11 15 2546 sgf t Single Fam Dei':. 240 deg (SW) 1 - 1 Slab on Grade 29104 tuft "2546 sqf t. 2546 sqf t Floor # of Vent Zone Name Area ; Volume Units Zone Type TStat Type Hgt Area ----------------------- ------ ------ -------------------------- --- ---- FAU/CU/COIL 1 .1833 20905 0.72 Living LivingStat 2 n/a FAU/CU/COIL 2 713 8200 0.28 Sleeping SleepStat 2 n/a OPAQUE SURFACES Act Solar Type Area U -Val Azm Tilt Gains ZONE NAME = FAU/CU/COIL 1 Form 3 Reference Location/Comments Wall .104 0.060 240 90 Yes R-21 Wall (W21.2x6.16) LIV/GIN/KIT Door 24 0.387 240 90 Yes Solid Wood Door LIV/DIN/KIT Wall 219 0.060 285 90 Yes R-21 Wall (W21.2x6.16.) LIV/DIN/KIT Wall 40 0.060 .15 90 Yes R-2.1 Wall (W2.1.2x6.16) LIV/DIN/KIT Wall 156 0.060 60 90 Yes R-21 Wall (W21.2x6.16) LIV/DIN/KIT Wall 176 0.060 105 90 Yes R-21 Wall (W2.1.2x6..16) LIV/DIN/KIT Wall 232. 0.060 .195 90 Yes R-21 Wall (W21.2x6.16) LIV/DIN/KIT Door 24 0.387 .195 90 Yes Solid Wood Door LIV/DIN/KIT Roof 47 0.030 240 0 Yes Built-up/R-38/Gypboard LIV/DIN/KIT Roof 1121 0.029 240 23 Yes Tile/R-38/Gypbd LIV/DIN/KIT Wall 18 0,.060 15 90 Yes R-21 Wall (W21.2x6.16) GUEST 1 Wall 232 0.060 105 90 Yes R-21 Wall (W21.2x6.16) GUEST 1 Wall 78 0.060 195 90 Yes R-21 Wall (W21.2x6.16) GUEST 1 Wall 70 0.057 15 90 Yes R-2.1 Partition (2x6.16) GUEST 1 Roof 365 0.030 240 0 Yes Built-up/R-38/Gypboard GUEST 1 ZONE NAME = FAU/CU/COIL. 2 Wall 17 0.060 285 90 Yes R-21 Wall (W21.2x6.16) MASTER SUITE Wall 69 0.060 315 90 Yes R-21 Wall (W21.2x6.16) MASTER SUITE Wall 480 0.060 0 90 Yes R-21 Wall (W21.2x6..16) MASTER. SUITE Wall 114 0'060 l50 90 Yes R-21 Wall (W21'2x6.16) MASTER SUITE Wall 87 0'060 195 90 Yes R-21 Wall (W21'2x6.16) MASTER SUITE Wall 40 0'057 225 90 Yes R-21 Partition (2x6'16) MASTER SUITE Wall 132 O'O57 286 90 Yes R-21 Partition (2x6'16) MASTER SUITE Wall 12 O'057 IS 90 Yes R-21 Partition (2x6.16) MASTER SUITE Roof 713 0'030 240 0 Yes Built-up/R-38/Gypboard MASTER SUITE COMPUTER METHOD SUMMARY C -2R, page 8 of 18 ---------------------------------------------------------------------------- Project Name: LOT 72 ;Date: 7/19/199.5 Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366 --------------------------------------------------------------------------- PERIMETER LOSSES F2 Insulation Type Length Factor R -Val Depth Location/Comments ZONE NAME = FAU/CU/COIL 1 Covered S4.0 0.72 0.0 0 in LIV/DIN/KIT Exposed S6.S 0.90 0.0 0 in LIV/GIN/KIT Covered 43.5 0.72 0.0 0 in GUEST 1 Exposed 12.0 0.90 0.0 0 in GUEST 1 ZONE NAME = FAU/CU/COIL 2 Covered 86.0 0.72 0.0 0 in MASTER SUITE Exposed 18.5 0.90 0.0 0 in MASTER SUITE FENESTRATION SURFACES Sc Act Glass # Type Area Frame Div U -Val Azm Tilt Only Location/Comments --------------- ----- ----- ---- ----- --- ---- ----- --------------------- ZONE NAME = FAU/CU/COIL 1 1 Wdw Front (SW) 76.0 Vinyl No 0.50 240 90 0.52 LIV/DIN/KIT 2 Wdw Front (W) 24.0 None No 0.57 2.8S 90 0.65 LIV/DIN/KIT 3 Wdw Front (W) 128.0 Vinyl No 0.50 28S 90 0.S2 LIV/DIN/KIT 4 Wdw Front (W) 32.0 Vinyl No 0.52 285 90 0.52 LIV/DIN/KIT 5 Wdw Back (NE) 96.0 Vinyl No 0.50 60 90 0.52 LIV/DIN/KIT 6 Wdw Back (E) 24.0 Vinyl No 0.52 105 90 0.52 LIV/DIN/KIT 7 Wdw Right (S) 12.0 Vinyl No 0.52 19S 90 0.52 LIV/DIN/KIT 8 Wdw Right (S) 18.0 Vinyl No 0.52 195 90 0.52 LIV/DIN/KIT 9 Wdw Back (E) 32.0 Vinyl No 0.52 105 90 0.52 GUEST 1 10 Wdw Back (E) 20.0 Vinyl No 0.S2 10S 90 0.52 GUEST I 11 Wdw Right (S) 48.0 Vinyl No 0.52 195 90 0.52 GUEST 1 ZONE NAME = FAU/CU/COIL 2 12 Wdw Front (W) 7.0 Vinyl No 0.52 285 90 0.52 MASTER SUITE 13 Wdw Front (W) 28.0 Vinyl No 0..52 285 90 0.52 MASTER SUITE 14 Wdw Left (N) 53.1 Vinyl No 0.52 0 90 0.S2 MASTER SUITE .15 Wdw Right (SE) 64.0 Vinyl No 0.52 150 90 0.52 MASTER SUITE 16 Wdw Right (SE) 20.0 Vinyl No 0.S2 ISO 90 0.52 MASTER SUITE 17 Wdw Right (S) 64.0 Vinyl No 0.52 195 90 0.S2 MASTER SUITE 18 Wdw Right (S) 16.0 Vinyl No 0.52 195 90 0.52 MASTER, SUITE INTERIOR. & EXTERIOR SHADING # Type Interior Shade Type Sc Exterior Shade Type Sc 1 Wdw Std Drape 0.78 Standard Bug Screen 0.87 2 Wdw Std Drape 0.78 Standard Bug Screen 0.87 3 Wdw Std Drape 0.78 Standard Bug Screen 0.87 4 Wdw Std Drape 0.78 Standard Bug Screen 0.87 S Wdw Std Drape 0.78 Standard Bug Screen 0.87 6 Wdw Std Drape 0.78 Standard Bug Screen 0.87 7 Wdw Std Drape 0.78 Standard Bug Screen 0.87 8 Wdw Std Drape 0.78 Standard Bug Screen 0.87 9 Wdw Std Drape 0.78 Standard Bug Screen 0.87 10 Wdw Std Drape 0.78 Standard Bug Screen 0.87 11 Wdw Std Drape 0.78 Standard Bug Screen 0.87 12 Wdw Std Drape 0.78 Standard Bug Screen 0.87 13 Wdw Std Drape 0.78 Standard Bug Screen 0.87 14 Wdw Std Drape 0.78 Standard Bug Screen 0.87 15 Wdw Std Drape 0.78 Standard Bug Screen 0.87. 16 Wdw Std Drape 0.78 Standard Bug Screen 0.87 17 Wdw Std Drape 0.78 Standard Bug Screen 0.87 18 Wdw Std Drape 0.78 Standard Bucy Screen 0.87 COMPUTER METHOD SUMMARY C -2R page 9 of 18 --------------------------------------------------------------------------- Project Name: LOT 72 ;Date: 7/19/1995 Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366 --------------------------------------------------------------------------- OVERHANGS/SIDE FINS -----Overhang------ Len Ht LExt RExt .13.5 1.0 13.5 13.5 13.5 1.0 13.S 13.5 6.S 1.0 6.5 6.S ---Left Fin--- ---Right Fin -- Dist Len Ht Dist Len Ht ---- ---- ---- ---- ---- ---- THERMAL MASS --Window-- # Type. Ht Wd 3 Wdw 8.0 8.0 4 Wdw 8.0 4.0 17 Wdw 8.0 8.0 -----Overhang------ Len Ht LExt RExt .13.5 1.0 13.5 13.5 13.5 1.0 13.S 13.5 6.S 1.0 6.5 6.S ---Left Fin--- ---Right Fin -- Dist Len Ht Dist Len Ht ---- ---- ---- ---- ---- ---- THERMAL MASS Area Thick Heat Inside Location Type (sf) (in) Cap Cond Form 3 Reference ---- ----- ----- --------------------------- R -Val. Comments ------ -------- ------------- ZONE NAME = FAU/CU/COIL 1 Covered Slab 700 3.50 28 0.98 n/a 2 Exposed Slab 768 3.50 28 0.98 n/a 0 Covered Slab 340 1.50 28 0.98 n/a 2 Exposed Slab 2S 3.50 28 0.98 n/a 0 ZONE NAME = FAU/CU/COIL 2 Covered Slab S93 3.50 28 0.98 n/a 2 Exposed Slab 120 3.50 28 0.98 n/a 0 HVAC SYSTEMS Minimum Distrib Type Duct TStat System Type Efficiency and Location RVal Type ---------------- ---- ------ Location/Comments ----------------------- ----- - ----- Furnace ---------- 0.801 AFUE Ducts in Attic 4.2 SetBck FAU/CU/COIL- 1 SpltAirCond12.1S0 SEER Ducts in Attic 4.2 SetBck Furnace 0.801 AFUE Ducts in Attic 4.2 SetBck FAU/CU/COIL 2 SpltAirCond12.0S0 SEER Ducts in Attic 4.2 SetBck Water No. Tank Ext. WATER HEATING SYSTEMS Heater in Energy Size Insul System Name Distribution Type Type -------- Sys ---- Factor (gal) R -Val ------ - ---- ----- ------------------------ AMERICAN APP ------------------ G52-SOT38- Pipe Insulation StorGas 1 0.60 50.0 0.0 AMERICAN APP GS2-50T38-- Recirc-Time&Temp StorGas 1 0.60 SO.0 0.0 AFUE WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot System Name System Type Eff Input Loss R -Val Light AMERICAN APP GS2-50T38- DomesticHW 0.760 38000 0.000 16.0 0 AMERICAN APP G52-SOT38- DomesticHW 0.760 38000 0.000 16.0 0 SPECIAL FEATURES/REMARKS V.A.V.TO GUEST 1 A Zonally Controlled HVAC System which meets CEC criteria has been assumed HVAC ZONE HEATING & COOLING LOAD SUMMARY page 10 of 18 Project Name: LOT 72 ;Date: 7/19/1995 Documentation: KROWN MECHANICAL_ DESIGN ;COMPLY 24 User 2366 --------------------------------------------------------------------------- HVAC ZONE DESCRIPTION HVAC Zone Name: FAU/CU/COIL 1 Heating System Name: LENNOX 80MGF4/5-12OA-** Cooling System Name: LENNOX HS2S-651/C22-65 System Multiplier: 1 Fan Schedule: 24 Hr Fans STD Peak Load Method: COINCIDENT Relative Humidity: 50 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool this zone during_ the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize by a reasonable°margin to account for variations in weather conditions and the pick-up capacity required to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final equipment selection should note that Sensible and Latent Cooling Loads are indicated to allow for accurate comparison with manufacturer's output data. COOLING SPACES IN THIS ZONE PEAK HEATING PEAK. SENSIBLE LATENT LIV/DIN/KIT (Jan 12am) 25589 (Aug 2pm) 28152 -811 GUEST 1 (Jan 12am) 7258 (Aug 2pm) 7185 -90 TOTAL SPACE LOAD 32847 35337 -901 Duct Gains & Losses: 3285 3534 Ventilation: ( 10 CFM) 0 0 0 Return Air Lighting Gain ------- 0 -------- ------ TOTAL. SYSTEM LOAD 36132 38871 -901 SYSTEM OUTPUT AT DESIGN CONDITIONS 98377 44168 10459 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool this zone during_ the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize by a reasonable°margin to account for variations in weather conditions and the pick-up capacity required to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final equipment selection should note that Sensible and Latent Cooling Loads are indicated to allow for accurate comparison with manufacturer's output data. RESIDENTIAL SPACE HEATING LOAD -SUMMARY page 11 of 18 Project Name: LOT 72 ;Date: 7/19/199.5 Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366 Space Name: LIV/DIN/ITT Design Indoor Dry Bulb Temperature: 70 F Design Outdoor Winter Dry Bulb Temperature: 32 F Design Temperature Difference: 38 F Conduction Area U -Value TD Btu/hr R-21 Wall (W21.2x6.16) 927.0 x .0.0596 x 38.0 - 2098 Solid Wood Door 48.0 x 0.3872 x 38.0 - 706 Low E Brnz Default (R)) 96.0 x 0.5000 x 38.0 = 1824 Low E Brnz Default (R)j 24.0 x O.S200 ;x 38.0 = 474 Low E Brnz Default (R)) 30:0 x 0:5200 x 38.0 = 593 Low E Brnz Default (R)) 76.0 x 0.5000 x 38.0 = 1444 Low E Brnz Default (R)) 128.0 'x O.SO00 x 38.0 = 2432 Low E Brnz Def au 1 t , ( R) ) 32.0 x 0 . 5200 x 38.0 = 632 Decora Glass Block (R) 24.0 x 0.5700 x 38.0 = S20 Built-up/R-38/Gypboard 47.0 x 0.0296 x 38.0 = S3 Tile/R-38/Gypbd 1121.3 x 0.0294 x 38.0 = 1254 Slab on.Grade Perim = 54.0 x 42 = 2241 Slab on Grade Perim = S6.S x 42 = 2345 Infiltration: 1.00 x 0.018 x 1468 sf x 12.0 ft x 0.75 AC x 38.0 = 8973 TOTAL HOURLY HEAT LOSS FOR SPACE 25589 Heating AirFlow: 25589 Btu/hr / [1.07 x 35 F DeltaT)1 = 682 cfm � RESIDENTIAL SPACE COOLING LOAD SUMMARY page 12 of 18 . -'-------------_---------__-_-----___----_----__---_---__--_-___----_--_ ---_ ProJeot Name: LOT 72 !Date: 7/19/1995 / ' Documentation: KROWN MECHANICAL DESIGN :COMPLY 24 User 2366 --------------------------------------------------------------------------- Spaoe Name: LIV/DIN/KIT Design Indoor Dry Bulb Temperature: 78 F Design Outdoor Summer Dry Bulb Temperature: 112 F Design Temperature Difference: ' 34 F Conduction Area U -Value _______ DETD ____ Btu/hr ------ _______________________ R-21 Wall (W21'2x6'16) ______ 927'0 x 0'0596 x 27.6 1524 Solid Wood Door 48'0 x 0'3872 x 27'6 = 513 Low E Brnz Default (R)) 96'0 x 0'5000 x 34.0 � 1632 Low E Brnz Default (R)) 24'0 x O'5300 x 34'0 424 Low E Brnz Default (R)) 30'0 x 0'5200 x 34'0 530 Low E Brnz Default (R)l 76,0 x 0'5000 x 34'0 1292 Low E Brnz Default (R)) l28'0 x 0'5000 x 34'0 2176 Low E Brnz Default (R)) 32'0 x 0'5200 x 34'0 566 Deoora Glass Block (R) 24'0 x 0'5700 x 34'0 465 Built-up/R-38/Gypboard 47'0 x 0'0296 x 48'0 67 Tile/R-38/Gypbd 1121'3 x 0'0294 x 48'0 = 1584 Infiltration: l'OO x 0.018 x 1468 sf x 12'0 ft x 0'75 AC x 34'0 8028 ~ Shaded Unshaded Solar Gain Orient' Area 8GF Area SGF SC ----------------------- --------- ---- --- ---- --- ---- Low E Brnz Default (R)) Southwest [ 0'0 x IS + 76'0 x 621 x 0'38 = Deoora Glass Block (R) West [ 0'0 x IS + 24'0 x 731 x O'59 = Low E Brnz Default (R)) West [ 128'0 x IS + O'O x 731 x 0'38 = Low E Brnz Default (Rl) West [ 32'0 x IS + O'O x 731 x 0'38 = Low E Brnz Default (R)) Northeast [ 0'0 x IS + 96'0 x 481 x 0'38 = Low E Brnz Default (R)) East [ 0'0 x IS f 24'0 x 731 x 0'38 � Low E Brnz Default (R)) South [ 0'0 x 15 + 12'0 x 321 x 0'38 � Low E Brnz Default (R)) South [ 0'0 x IS + 18'0 x 32] x 0'38 � Internal 'Gain Op Frac. Area Heat Gain Conv' ----------------------- -------- ------ --------- ----- Lighting l'OO x 1468.3 x 0`200 x 3'413 = Equipment 1'00 x 1468'3 x 0'100 x 3'413 � Occupants l'OO x 1468'3 x 22S / 333 � TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE Latent Gain Op Frac. Area Heat Gain Conv' Equipment 1.00 x 1468'3 x 0'000 x 3'413 Occupants 1'80 x 1468'3 x 22S / 333 Infiltration: l'OO x 0'018 x 1468 af x 12'0 ft x 0'75 AC x -7'0 TOTAL HOURLY LATENT HEAT GAIN FOR SPACE 1792 1041 730 183 l7S3 666 146 219 1002 501 992 ------ 28152 Btu/hr Cooling AirFIow: 28152 Btu/hr / [1'07 x 23 F DeltaT)] = 1142 ofm RESIDENTIAL SPACE HEATING LOAD SUMMARY page 13 of 18 Project Name: LOT 72 ;Date: 7/19/1095 Documentation: YROWN MECHANICAL DESIGN ;COMPLY 24 User 2366 --------------------------------------------------------------------------- Space Name: GUEST 1 Design Indoor Dry Bulb Temperature: 70 F Design Outdoor Winter Dry Bulb Temperature: 32 F Design Temperature Difference: 38 F Conduction R-21 Wall (W21.2x6.16) R-21 Partition (2.x6.16) Low E Brnz Default (R)) Low E Brnz Default (R)) Built-up/P.-38/Gypboard Slab on Grade Slab on Grade Infiltration: 1.00 x 0.018 x Heating AirFlow: 7258 Btu/hr /"[1.07 x 35 F DeltaT).] = 193 cfm Area U -Value TD Btu/hr 328.0 x O.OS96 x 38.0 = 742 70,.0 x 0.0574 x 38.0 - 153 52.0 x 0.5200 x 38.0 = 1028 48.0 0.5200 x 38.0 = 948 365.0 x 0.0296 x 38.0 - 411 Perim = 43.5 x 42 = 1805* Perim = .1.2.0 x 42 = 498 365 sf x 9.0 ft x 0.7S AC x 38.0 = 1673 TOTAL HOURLY HEAT LOSS FOR SPACE 7258 Heating AirFlow: 7258 Btu/hr /"[1.07 x 35 F DeltaT).] = 193 cfm RESIDENTIAL SPACE. COOLING LOAD SUMMARY page .14 of 18 -------•--------------------------------------------=-------------------- --- Project Name: LOT 72 ;Date: 7/.19/199.5 I Documentation: KROWN MECHANICAL DE -SIGN ;COMPLY 24 User 2366 ---------------------------------------------------------------------------- Space Name: GUEST 1 Design Indoor Dry Bulb Temperature: 78 F Design Outdoor Summer Dry Bulb Temperature: 112 F Design Temperature Difference: 34 F Conduction Area ------ U -Value ------- DETD ---- Btu./hr ------ ------------------------ R-21 Wall (W21.2x6.16) 328.0 x 0.0596 x 27.6 = 539 R-21 Partition (2x6.1.6) 70.0 x 0.0574 x 27.6 = 111 Low E Brnz Default (R)) 52.0 x 0.5200 x 34.0 = 919 Low E Brnz Default (R)) 48.0 x 0.5200 x 34.0 = 849 Built-up/R-38/Gypboard 365.0 x 0.0296 x. 48.0 = 519 Infiltration: 1.00 x 0.018 x 365 sf x 9.0 ft x 0.75 AC x 34.0 = 1497 Shaded Unshaded Solar Gain Orient. Area SGF --- Area SGF ---- --- SC ---- ----------------------- Low E Brnz Default ( R) ,) --------- East [ ---- 0.0 x 15 + 32.0 x 731 x 0.38 = 888 Low E Brnz Default (R)) East f 0.0 x 15 + 20.0 x 731 x 0.38 = S55 Low E: Brnz Default (R)) South (. 0.0 x 15 + 48.0 x 32) x 0.38 = 584 Internal Gain Op Frac.. Area Heat Gain Conv. Lighting .1.00 x 365.0 x 0.200 x 3.413 = 249 Equipment 1.00 x 365.0 x 0.1.00 x 3.413 = 125 Occupants 1.00 x 365.0 x 22S / 333 - 247 TOTAL_ HOURLY SENSIBLE HEAT GAIN FOR SPACE 7185 Latent Gain Op Frac. Area Heat Gain Conv,. Btu./hr Equipment 1.00 x 365.0 x 0.000 x 3.413 = 0 Occupants 1.00 x 365.0 x 225 / 333 = 247 Infiltration: 1.00 x 0.018 x 365 sf x 9.0 ft x 0,.75 AC x -7.0 - -308 TOTAL HOURLY LATENT HEAT GAIN FOR SPACE -90 Cooling AirFlow: 7185 Btu/hr / [1.07 x. 23 F DeltaT).] = 291 cfm HVAC ZONE HEATING & COOLING LOAD SUMMARY rage 15 of 18 _..--------------------------------•------------------------------------------- Pro.ject Name: LOT 72 ;Date: 7/19/1995 Documentation: KROWN MECHANICAL DESIGN :COMPLY 24 User 2366 ---------------------------------------------------------------------------- HVAC ZONE DESCRIPTION HVAC Zone Name: FAU/CU%COIL 2 Heating System Name: LENNOX 80MGF2--45A-** Cooling System Name: LENNOX HS25-261iC22-26 System Multiplier: 1 Fan Schedule: 24 Hr Fans STD Peak Load Method: COINCIDENT Relative Humidity: 50 0 COOLING SPACES Iii THIS ZONE PEAK HEATING PEAK SENSIBLE LATENT ----------------------- ----------- ------------ ------ MASTER SUITE (Jan 12am) 16432 (Aug. 2pm) 16017 -3S7 TOTAL- SPACE LOAD 16432 16017 -3S7 Duct Gains & Losses: 1643 1602 Ventilation: ( 0 CFM) 0 0 0 Return Air Lighting Gain 0 TOTAL- SYSTEM LOAD .18075 17619 -357 SYSTEM OUTPUT AT DESIGN CONDITIONS 36903 18240 3794 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool this zone during_ the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize,by a reasonable margin to account for variations in weather conditions and the pick-up capacity required to bring the zone to temper- ature as a result of a setback thermostat.. Those responsible for final equipment selection should note that Sensible and Latent Cooling Loads are indicated to allow for accurate comparison with manufacturer's output data. RESIDENTIAL SPACE HEATING LOAD SUMMARY page 16'of 1.8 ----------------------------------------------------------- Project Name: LOT 72 - ;Date: 7/19%1995 Documentation: KROWN MECHANICAL DESIGN -----------------------------------------7----------------------------------- ;COMPLY 24 User 2366 Space Name:. MASTER SUITE Design .Indoor Dry Bulb Temperature: 70 F Design Outdoor Winter Dry Bulb Temperature: 32 F Design Temperature Difference: 38 F' Conduction Area U -Value TD Btu/hr R--21 Wall (W21.2x6.16) 766.9 x 0.0.596 x 38.0 = 1736 R-2.1 Partition ( 2x6.16) 183.5 x 0:0574 x 38.0 = 401 Low E Brnz Default (R)) 53.1 x 0.5200 x 38.0 = 1049 Low E. Brnz Default (R) ) 84.0 x O . S200 x.38.0 = 1660 Low E Brnz Default (R)) 16.0 x 0.5200 x, 38.0 = 316 Low E Brnz Default (R A 64.0 x 0.5200. x 38.0 = 1265 Low E Brnz Default (R)'') 35.0 x 0.5200 x 38. 0 - 692 Built--up/R-38/Gyoboard 713.0 x 0„0296 x-38.0 = 802 Slab on Grade Perim = 86.0 x 42 = 3569 Slab on Grade Perim = 18.5 x 42 - 768 Infiltration: 1.00 x0.018 x 713 sf x 11..5 ft x 0.75 AC x 38.0 - 4175 TOTAL HOURLY HEAT LOSS FOR SPACE 16432 Heating AirFlow: 16432 Btu/hr /.(1.07 x' 35 F DeltaT)_1 = 438 cfm RESIDENTIAL SPACE COOLING LOAD SUMMARY page 17 of 18 Project Name: LOT 72 ;Date: 7/.19/1995 Documentation: <ROWN MECHANICAL DESIGN ;COMPLY 24 User 2366 ------------------ -------------------------------------------------------- Space Name: MASTER SUITE Design Indoor Dry Bulb Temperature: 78 F Design Outdoor Summer Dry Bulb Temperature: 112 F Design Temperature Difference: 34 F Conduction Area U -Value ------- DETD ---- Btu/hr ------ ----------------------- R-21 Wall (W21.2x6.16) ------ 766.9 x 0.0596 x 27.6 = .126.1 R-21 Partition (2x6.16) 183.5 x 0.0574 x 27.6 = 291 Low E Brnz Default (R)') 53.1 x 0.5200 x 34.0 = 939 Low E Brnz Default (R)) 84.0 x 0.5200 x 34.0 = 1485 Low E Brnz Default (R)) 16.0 x 0.5200 x 34.0 = 283 Low E Brnz Default (R.) ) 64.0 x 0.5200 x 34.0 - 1132 Low E Brnz Default ( R)) 3S.0 x 0 . 5200 x 34.0 - 619 Built-up/R-38/Gypboard 713.0 x 0.0296 x 48.0 - 1013 Infiltration: .1.00 x 0.018 x 713 sf x 1.1.5 ft x. 0.75 AC x 34.0 = 3736 Shaded Unshaded Solar Gain Orient. Area SGF Area SGF --- Sc ---- ----------------------- Low E Brnz Default (R)) --------- West ---- --- 0.0 x 15 + ---- 7.0 x 731 x 0.38 = .194 Low E Brnz Default ( R) ,) West 0.0 x 15 + 28.0 x 73.1 x 0.38 = 777 Low E Brnz Default (R)) North f 0.0 x 15 + S3..1 x 151 x 0.38 = 303 Low E Brnz Default (R)) Southeast [ 0.0 x 15 + 64.0 x 621 x 0.38 = 1509 Low E Brnz Default (R)) Southeast. f 0.0 x 15 + 20.0 x 621 x 0.38 = 472 Low E Brnz Default (R)) South ( 64.0 x. 15 + 0.0 x 321 x 0.38 = 36S Low E Brnz Default (R)) South [ 0.0 x IS + 16.0 x 321 x 0.38 = 195 Internal Gain Op Frac. Area Heat Gain Conv. Lighting 1,.00 x 713.0 x 0.200 x 3.413 = 487 Equipment 1.00 x 713.0 :<: 0.100 x 3.41.3 - 243 Occupants .1.00 x 7.13.0 x 225 / 333 = 482 TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE 16017 Latent Gain Op Frac. Area Heat Gain Conv. Btu/hr Equipment 1.00 x 713.0 x 0.000 x 3.413 = 0 Occupants 1.00 x 713.0 x 225 / 333 = 482 Infiltration: 1,.00 x 0.018 x 713 sf x 11.S ft x 0.75 AC x -7.0 = -770 TOTAL HOURLY LATENT -TEAT GAIN FOR SPACE -357 Cooling AirFlow: 16017 Btu/hr / (1.07 x 23 F DeltaT)1 = 650 cfm INSTALLATION CERTIFICATE CF -6R page 18 of 18 • --------------------------------------------------------------------------- Project Name: LOT 72 ;Date: 7/19/199.5 Documentation: YROWN MECHANICAL DESIGN ;COMPLY 24 User 2366 --------------------------------------------------------------------------- I, the undersigned, verify that the equipment listed in the category above illy signature is the actual equipment installed and that the equipment meets or exceeds the requirements of the Appliance Efficiency Standards. In addition, I have verified that the equipment is equivalent to or more efficient than the equipment specified on the Certificate of Compliance submitted to demonstrate compliance with the Energy Efficiency Standards for residential buildings. HVAC SYSTEMS Heat. Equip CEC Certified Manuf. Actual Distrib Type Duct Heat Heat System Type Make & Model Number Eff. .and Location RVal Load Output ------------ --------- - ------------- ------------------- ---- ------ ------ Furnace LENNOX 80MGF4/S-12OA-** 0.801 Ducts in Attic 4.2 36132 98377 Furnace LENNOX 80MGF2145A-** 0.801 Ducts in Attic 4.2 18075 36903 Cool. Equip CEC Certified Manuf. Actual Distrib Type Duct System Type Make & Model Number Efficiency andLocation RVal SpltAirCond LENNOX HS2S-651/C22-6S 1.2.150 SEER Ducts in Attic 4.2 SpltAirCond LENNOX HS2.5-26l/C22--26 1"2.050 SEER Ducts in Attic 4.2 Signature Date Name Water No. Tank Ext. WATER HEATING SYSTEMS Heater in Energy Size Insul CEC Cert. Make & Model Distribution Type Type Sys Factor'(gal) R -Val AMERICAN APP GS2-SOT38- Pipe Insulation StorGas 1 0.60 50.0 0.0 AMERICAN APP GS2••-50T38- Recirc-Time&Temp StorGas 1 0.60 50.0 0.0 AFUE WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot System Name System Type Eff Input Loss R -Val Light AMERICAN APP G52-SOT38- DomesticHW 0.760 38000 0.000 16.0 0 AMERICAN APP G52-.5GT38- DomesticHW 0.760 38000 0.000 16.0 0 FAUCETS & SHOWER HEADS: All faucets and showerheads are listed in the Commissions Directory Of Certified Faucets And Showerheads, pursuant, to Title 24, Part 6, Subchapter 2, Section Ill. Signature Date Name DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated 619-775-3500 Date 110/17/951 Type of Permit La Quinta No. 113768 1 Permit # Owner Name La Quinta Golf Properties Log No. 79480 Street Tom Fazio Lane North City La Quinta Zip 92253 Study Area 108 APN # 761-521-002 Tract # 128189 Lot # 0 Square Footage 12546 Type of Development I Single Family Residence No. of units 0 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.72 x 2 546 or $ 4,379.12 have been paid to D.S.U.S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By La Quinta golf Propertiesd, Inc. Telephone 777-110`0 Name on the check By Dolores A. Ballesteros 1'= Superintendent Fee collected /exempted by Pauline Pearson Payment Received Signature $4,379.12 Check No. 23309 Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting