9510-047 (SFD)i
r¢,
LICENSED CONTRACTOR DECLARATION x
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my
"license is in full force and effect. 70641.0 8 5(31/97
License # Lic. Class Exp. Date
Date Signatureof Contractor
~ OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the,
following "reason:
() I; as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
() I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals Code).
( ) I am exempt under Section , B&P.C. for this reason
Date Signature of Owner
WORKER'S. COMPENSATION DECLARATION
I•hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier Policy No.
(This section neeCl oot pecompleted if the permit valuatio0 i.'bjo ,$1:W.00 or less).
() I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section 3700 of the Labor
Code, I shall forthwith comply with those provisions.
Date: Applicant
Warning: Failure to secure Workers' Compensation coverage is unlawful and shall
subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his application.
1. Each person upon whose be this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this application agrees to, & shall, indemnify
& hold harmless the City of Indian Wells, its officers, agents and employees,,
2. Any permit issued as a result of this application becomes null and void -if
work is not commenced within 180 days from date of issuance of syc
permit, or cessation of work for 180 days will subject permit to cancellatio (�'
I certify that I have read this application and state that the above inform' /'on ip
correct. I agree to_comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon the
above-mentioned property for inspection purposes: t y
Signature (Owner/Agent) Dats
ALCM'
v BUILDING PERMIT
PERMITya�1fA
-DATE 1111141%0'
VALUATION .5 'bii..11. -.A43
LOT
TRACT zt,=-O'f Gi
JOB SITE ADDRESS 79-484) TOM FAZIO i,AVE NWIVIR
APN
V
OWNER
CONTRACTOR ,
17_JR:PI1d CONS'ITt.UCIION CO.
LA QtJINTA GOLF PROPE
549361 91-10M, CREEK
75 -UO TONT FAZIO LANE NORTH
LA QUINT CA 92253
LA QU7NTA CA 92253
(61.9)777-7611 C001 3751
(C-19)777-1100
DESIGNER/ENGINEER
HABITAT
74105 i'VIOCKiNGIBIRRD
USE OF PERMIT! NGLL' YAN.IiLY OWtUTLINU
MOIAN WELLS. CA 92210 SL#2WR
I'146 QUA3tKY
PEWIT DOES NOT INIC1,IME BLOCK WALLS OR POOL.
FEE DESCRIPTION
FEES
Ctisrom'CO NSTRUC",1'1C).N' 2,:44fi.U0.LF
GAP,A(WJCARPOWf 67COO SF
PORCK(.PA'IIO 644.00 SF
ESUMATED COST OF CONSTRUCTION
220,148.20
PERMIT VCE SSU? Y
f
FEF, DEPOSIT 42,50.00
PLAN CRW- rtes 101.000-439-318 SM321
CONS 101-000418-000 $L063.33
9F. CBANIC'•AL FFA 101-Oi:10-421.000 $102.50
FfY,CTRICAL FEE 101-400420-000 $175.13
PLUNAWmiG VEE 1014000.419-000 $211.50
SIX)NG b O i tON 1U -12ESID 100-000-241»M $^2.41
GRADING I',13 101 -000 -423 -ON 520.00
INFIWIN IC-17URE FE!l 225.000-443.342 1$3,760,6:
ART IN" PUBLIC PLACES -1ZE.Sir, 70:1-000-255-000 3308.3;
SIM -TOT AL CONS' RJ JCT ION .1'* 0 PLAN CHECK.-
Op7,53'7. 79
n LESS PRE -PAID PEES
4250.00
TOT'AI P. RMff FEES. 1)l:II!,NOW
S7; 87.79
T 3 0 1995 i
TCW, PROJECT PE tl M(f .(«11ES
7 sm /9
RECEIPT
DATE
BY
DATE RNALED
INSPECTOR
INSPECTION RECORD
OPERATION
DATE
TINSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K. to Wrap
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
Final
POOLS - SPAS
BLOCKWALL APPROVALS
steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
Appliances
Final
COMMENTS:
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G IF.l.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
I
`o
_ s CITY OF LA QtUINTA
BUILDING & SAFETY DEPARTMENT
VO�Oj 777-7012
}x INSPECTION REQUEST LINE
777-7153
Off' QUINTA GOLF PROPERTIES
j'Owner
TURPIN CONSTRUCTION
Contractor
.9510-047
Permit Number
POST ON JOB IN CONSPICUOUS PLACE
INSPECTOR MUST SIGN ALL APPLICABLE SPACES
I 79430 TOM FAZIO LANE NORTH
i
JOB ADDRESS
SFD PERMIT DOES NOT INCLUDE BLOCK
WALL OR POOL.
TYPE OF INSPECTION DATE INSP.
FOUNDATION & SETBACK
j FOOTING STEEL —
k MAIN GROUND SYSTEM
GROUND PLUMBING
PRE-GUNITE .
DO NOT POUR CONCRETE UNTIL ALL ABO HA EENIGNED
CONCRETE SLAB —
JOISTS & GIRDERS
ELECTRICAL GROUND WORK
DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNED
ROUGH ELECTRIC
ROUGH PLUMBING
'ROUGH GAS & GAS TEST
HEATING & VENT - A/C
FIREPLACE
ROOF
BOND BEAM
O.K. TO WRAP
FRAMING
COVER NO WORK UNTIL ABOVE HAS BEEN SIGNED
DRYWALL INTERIOR
EXTERIOR LATH
POOL PRE PLASTER
POOL FENCE & GATE
SEWER SEPTIC TANK
FINALS
ELECTRICAL "
P[,, MBING.
i FINAL GAS TEST
i
HEATING - A/C
{ ..HOUSE NUMBERS
JOB COMPLETED
TEMP POWER
u
t
s
TITLE 24 REPORT FOR:
LOT 72
THE QUARRY
LA QUINTA: CA.
PROJECT DESIGNER:
HABITAT
74105 MOCKINGBIRD TRAIL.
INDIAN JELLS, CA.
(619) 568-3670
REPORT PREPARED BY:
R.Krown. CEA R92-93 204,
KROWN MECHANICAL. DESIGN
P.O.BM( 1761
LA QUINTA, CA 92253
(619) 773-2623
Job Number: 95052-3
Date: 7/19/1995
Certified BROW Aselle
Aia�d F. !lain
'O'f /;Z s�
rr
rr
CABEC.
calftff of building En*W ConsA"
The COMPLY 24 computer program has been used to perform the. calculations
s summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the
Residential and Nonresidential Building Energy Efficiency Standards.
This program developed by Gabel Dodd Associates (510) 428-0803.
Table Of- Contents .-for, Title 24 Report
C.............Paae ................:............ 1
Table of Contents ................................................... 2
Form CF -IR -Certificate of Compliance:: Residential ................... 31
Form MF -.1R Mandatory Measures Checklist: Residential ................ 5
Form C -2R Computer Method Summary .................................... 7
HVAC Zone & Space Loads Summary ...................................... 10
Form CF -6R Installation Certificate. Residential .................... 18
CERTIFICATE OF COMPLIANCE: Residential (part 1 of 2) CF -1R page 3 of 18
Project Name: LOT 72 ;Date: 7/19/1995
Address: THE QUARRY
LA QUINTA, CA. ;Building Permit No
Designer: HABITAT ;Checked by / Date
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
----------------------------------------------- ---------------------------
GENERAL INFORMATION
Compliance Method: COMPLY 24 version 4.11
Climate Zone: 15
Conditioned Floor Area: 2546 sqft
Building Type: Single Fam Det:.
Building Front Orientation: 240 deg (SW)
Number of Dwelling Units: 1
Floor Construction Type: Slab on Grade
BUILDING SHELL_ INSULATION
Component U -Value Location/Comments
R-21 Wall (W21.2x6.16) 0.060 LIV/DIN/KIT
Solid Wood Door 0.387 LIV/DIN/KIT
R-21 Wall (W21.2x6.16) 0.060 GUEST I
R-21 Partition (2x6,.16) 0.057 GUEST :.1.
R•-21 Wall (W21.2x6.16) 0.060 MASTER SUITE
R-21 Partition (2x6.16) 0.057 MASTER, SUITE
Built--up/R-38/Gypboard 0.030 LIV/DIN/KIT
Tile/R-38/Gypbd 0.029 LIV/DIN/KIT
Built-up/R-38/Gypboard 0.030 GUEST 1
Built-•up/R-38/Gypboard 0.030 MASTER SUITE:
Slab Perimeter w/R-0.0 0.720 LIV/DIN/KIT
Slab Perimeter w/R.-0.0 0.900 LIV/DIN/KIT
Slab Perimeter w/R-0.0 0.720 GUEST 1
Slab Perimeter w/R-0.0 0.900 GUEST I
Slab Perimeter w/R-0.0 0.720 MASTER SUITE
Slab Perimeter w/R-0.0 0.900 DIASTER SUITE
FENESTRATION Shading_ Devices Frame
Orient. Area U -Val Type Interior Exterior OH SF Type
--------- ------ ----- ------------------------------------ -- -- -----
Left (N) 53.1 0..52 Double Std Drape Standard Bug Scr N N Vinyl
Back (NE) 96.0 0.50 Double Std Drape Standard Bug Scr N N Vinyl
Back (E) 76.0 0.52 Double Std Drape Standard Bug ScrN N Vinyl
Right (SE) 84.0 0.52 Double Std Drape Standard Bug Scr N N Vinyl
Right. (S) 94.0 0.52 Double Std Drape Standard Bug Scr N N Vinyl
Right (S) 64.0 0.52 Double Std Drape Standard Bug Scr Y N Vinyl
Front (SW) 76.0 0.50 Double Std Drape Standard Bug Scr N N Vinyl
Front (W) 128.0 0.50 Double Std Drape Standard Bug Scr Y N Vinyl
Front (W) 3S.0 0.52 Double Std Drape Standard Bug Scr N N Vinyl
Front (W) 32.0 0,52 Double Std Drape Standard Bug Scr Y N Vinyl
Front (W) 24.0 0.57 Double Std Drape Standard Bug Scr N N None
THERMAL MASS Area Thick
Type Covering (sf) (in) Location/Description
----------------------------- ----- ----- ------------------------------
Concrete, Heavyweight Covered 700 3.50 Slab on Grade
Concrete, Heavyweight Exposed 768 3.50 Slab on Grade
Concrete, Heavyweight Covered 340 3.50 Slab on Grade:
Concrete, Heavyweight Exposed 25 3.50 Slab on Grade
Concrete, Heavyweight Covered 593 3.50 Slab on Grade
Concrete. Heavyweight Exposed 120 3.50 Slab on Grade
CERT.IFICATE OF
COMPLIANCE: Residential (part 2 of 2 )
CF -1R
page 4 of 18
---------------------------------------------------------------------------
Project Name:
LOT 72
;Date:
7/19/1995
Documentation:
---------------------------------------------------------------------------
KROWN MECHANICAL DESIGN
;COMPLY
24 User 2366
HVAC SYSTEMS Minimum Distrib Type
System Type Efficiency and Location
Furnace 0.801 AFUE Ducts in Attic
SpltAirCondl2.150 SEER Ducts in Attic
Furnace 0.801 AFUE Ducts in Attic
SpltAirCondl2.050 SEER Ducts in Attic
Duct TStat
RVal Type Location/Comments
4.2 SetBck FAU/CU/CO.IL 1
4.2 SetBck
4.2 SetBck FAU/CU/COIL 2
4.2 SetBck
Water No. Tank Ext.
WATER. HEATING SYSTEMS Heater in Energy Size Insul
System Name Distribution Type Type Sys Factor (gal) R -Val
----------------------- -------------- - ---------- --- ------ ----- -----
AMERICAN APP G52 -50T38- Pipe Insulation Storuas 1 0.60 50.0 0.0
AMERICAN APP G52-5OT38-- Recirc-Time&Temp StorGas 1 0.60 50.0 0.0
AFUE
WATER HEATER EQUIPMENT DETAIL_ /R,ec Rated Stdby Tank Pilot
System Name System Type Eff Input Loss R -Val Light
----------------------- ----------- ---- ----- ----- ----- ------
AMERICAN APP G52 -50T38- DomesticHW 0.760 38000 0.000 16.0 0
AMERICAN APP G.52 --50T38- DomesticHW 0.760 38000 0.000 16.0 0
SPECIAL FEATURES/REMARKS
V.A.V.TO GUEST I
A Zonally Controlled HVAC System which meets CEC criteria has been assumed
COMPLIANCE STATEMENT
This Certificate of Compliance lists the building features and performance
specifications needed to comply with Title .24, Parts 1 & 6 of the Califor-
nia Code of Regulations, and the administrative regulations to implement
them. This certificate has been signed by the individual with overall
design responsibility. When this certificate of compliance is submitted for
a single building plan to be built in multiple orientations, any shading
feature that is varied is indicated in the Special Features/Remarks section
DESIGNER or OWNER
(Per Business & Professions
HABITAT
74105 MOCKINGBIRD TRAIL
INDIAN WELLS, CA.
(619) 568-3670 Lic #:
(signature)
ENFORCEMENT
Name:
Title:
Agency:
Telephone:_
AGENCY
Code)
(date)
DOCUMENTATION AUTHOR
R.Krown, CEA R92-93 204
KROWN MECHANICAL_ DESIGN
P.O.BOX 176.1
LA QUINTA, CA 92253
(619) 773-2623
i 711 7/f
ignature) (date)
(signature/stamp) (date)
MANDATORY MEASURES CHECKLIST (part 1 of 2 ) MF --IR page 5 of 18
---------------------------------------------------------------------------
Project Mame: LOT 72 ;Date: 7;'190995
Documentation: KP.OWN MECHANICAL. DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
NOTE: Lowrise residential buildings subject to the Standards must contain
these measures regardless of the compliance approach used. Items marked
with an asterisk (*) may be superseded by more stringent compliance
requirements listed on the Certificate of Compliance. When this checklist
is incorporated into the permit documents, the features noted shall be
considered by all parties as binding minimum component performance
specifications for the mandatory measures whether they are shown elsewhere
in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
Enforcement
o Sec. ISM): Minimum R-19 ceiling insulation.
o Sec. 1.50(b): Loose fill insulation manufacturers
labeled P. -Value.
o Sec. 150(c): Minimum R-13 wall insulation in framed walls
(does not apply to exterior mass walls).
o Sec. ISO(d): Minimum R-13 raised floor insulation in framed
floors: Minimum R-8 in concrete raised floors.
o Sec. 150(1): Slab edge insulation - water absorption rate
no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
o Sec. 118: Insulation specified or installed meets California
Energy Commission quality standards. Indicate Type & form.
o Sec. 116-117: Fenestration Products, Ext Doors & Infil/Exfil Controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Manufactured fenestration products have label w/certified U -Value
c. Exterior doors and windows weatherstripped; all :joints
and penetrations caulked and sealed.
o Sec. 150(g): Vapor barriers mandatory in Climate Zones 14
and 16 only.
o Sec. 150(f): Special infiltration barrier installed to
.comply with Sec. .151 meets Commission quality standards.
o Sec. 150(e): Installation of Fireplaces. Decorative Gas
Appliances and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
MANDATORY MEASURES CHECKLIST (part; 2 of 2 ) MF -1R page 6 of 18
-----------------------------------------
Project. Name: LOT 72 ;Date: 7/19/1995
Documentation: YP.OWN MECHANICAL DESIGN ;COMPLY 24 User 2366
-----------------------------------------------------------------------------
SPACE CONDITIONING. WATER HEATING AND PLUMBING SYSTEM MEASURES Enforcement
o Sec. 110-13: HVAC equipment, water heaters, showerheads
and faucets certified by the Commission.
o Sec. 150(1): Setback thermostat on all applicable
heating systems.
o Sec.
1.
2.
3.
4.
S.
o Sec.
1.
2.
3.
150(.1): Pipe and Tank Insulation
Indirect hot water tanks (eg unfired storage tanks or
backup solar hot water tanks) have insulation blanket
(R-12 or greater) or combined interior/exterior insulation
(R=16 or (:ireater).
First 5 feet of pipes closest to water heater tank,
non -recirculation systems, insulated (P,-4 or greater.
All buried or exposed pipina insulated in recirculation
sections of hot water system.
Cooling system piping below 55 F insulated.
Piping insulated between heatina source and indirect hot
water tank. _
150(m) Ducts and Fans
Ducts constructed, installed and sealed to comply with
UMC Sections 1002 and .1004: ducats insulated to a minimum
R-4.2 or ducts enclosed entirely within conditioned space.
Exhaust systems have backdraft or automatic dampers.
Gravity ventilating systems serving conditioned space have
either automatic or readily accessible manually operated
dampers. _
o Sec. 114:Pool and Spa Heating Systems and Equipment
I. System is certified with 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric:
resistance heating and no pilot light.
2. System is installed with:
a. At least 36'' pipe between -filter and heater t'or future
solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch.
o Sec. 1].5: Gas-fired central furnace, pool heater, spa heater
or household cookina appliance have no continuously
burning pilot light. (.Excepti.on: Non -electrical cookinc.i
appliance with pilot < 150 Btuh)
LIGHTING MEASURES
o Sec. 150(k): Liahtina - 40 lumens/watt or areater for
general liahting in kitchens and rooms with water closets:
and recessed ceiling fixtures IC (insulation cover) approved.
COMPUTER METHOD SUMMARY
.104
C -2P,
page 7 of 18
---------------------------------------------------------------------------
Project. Name: LOT 72
Yes
;Date:
7/19/1995
Documentation: KROWN MECHANICAL_ DESIGN
.---------------------------------------------------------------------------
LIV/GIN/KIT
;COMPLY
24 User 2366
0.387
Standard
Proposed
Compliance
Source Energy Use (KBtu/sf-y�)
Design
Design
Margin
Space Heating
3.99
4.10
-0.10
Space Cooling
30.22
27.81
2.4.1
Domestic Hot Water
10.26
11.87
--------
-1.61
----------
TOTALS
--------
44.47
43.78
0.69
*** BUILDING COMPLIES ***
GENERAL. INFORMATION
Compliance Method:
Climate Zone.
Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
Number of Stories:
Floor Construction Type:
Total Conditioned Volume:
Conditioned Footprint Area:
Ground Floor Area:
BUILDING ZONE INFORMATION
COMPLY 24 version 4.11
15
2546 sgf t
Single Fam Dei':.
240 deg (SW)
1 -
1
Slab on Grade
29104 tuft
"2546 sqf t.
2546 sqf t
Floor # of Vent
Zone Name Area ; Volume Units Zone Type TStat Type Hgt Area
----------------------- ------ ------ -------------------------- --- ----
FAU/CU/COIL 1 .1833 20905 0.72 Living LivingStat 2 n/a
FAU/CU/COIL 2 713 8200 0.28 Sleeping SleepStat 2 n/a
OPAQUE SURFACES Act Solar
Type Area U -Val Azm Tilt Gains
ZONE NAME = FAU/CU/COIL 1
Form 3 Reference Location/Comments
Wall
.104
0.060
240
90
Yes
R-21
Wall
(W21.2x6.16)
LIV/GIN/KIT
Door
24
0.387
240
90
Yes
Solid Wood
Door
LIV/DIN/KIT
Wall
219
0.060
285
90
Yes
R-21
Wall
(W21.2x6.16.)
LIV/DIN/KIT
Wall
40
0.060
.15
90
Yes
R-2.1
Wall
(W2.1.2x6.16)
LIV/DIN/KIT
Wall
156
0.060
60
90
Yes
R-21
Wall
(W21.2x6.16)
LIV/DIN/KIT
Wall
176
0.060
105
90
Yes
R-21
Wall
(W2.1.2x6..16)
LIV/DIN/KIT
Wall
232.
0.060
.195
90
Yes
R-21
Wall
(W21.2x6.16)
LIV/DIN/KIT
Door
24
0.387
.195
90
Yes
Solid
Wood
Door
LIV/DIN/KIT
Roof
47
0.030
240
0
Yes
Built-up/R-38/Gypboard
LIV/DIN/KIT
Roof
1121
0.029
240
23
Yes
Tile/R-38/Gypbd
LIV/DIN/KIT
Wall
18
0,.060
15
90
Yes
R-21
Wall
(W21.2x6.16)
GUEST 1
Wall
232
0.060
105
90
Yes
R-21
Wall
(W21.2x6.16)
GUEST 1
Wall
78
0.060
195
90
Yes
R-21
Wall
(W21.2x6.16)
GUEST 1
Wall
70
0.057
15
90
Yes
R-2.1
Partition
(2x6.16)
GUEST 1
Roof
365
0.030
240
0
Yes
Built-up/R-38/Gypboard
GUEST 1
ZONE
NAME
= FAU/CU/COIL. 2
Wall
17
0.060
285
90
Yes
R-21
Wall
(W21.2x6.16)
MASTER SUITE
Wall
69
0.060
315
90
Yes
R-21
Wall
(W21.2x6.16)
MASTER SUITE
Wall
480
0.060
0
90
Yes
R-21
Wall
(W21.2x6..16)
MASTER. SUITE
Wall
114
0'060
l50
90
Yes
R-21
Wall (W21'2x6.16)
MASTER
SUITE
Wall
87
0'060
195
90
Yes
R-21
Wall (W21'2x6.16)
MASTER
SUITE
Wall
40
0'057
225
90
Yes
R-21
Partition (2x6'16)
MASTER
SUITE
Wall
132
O'O57
286
90
Yes
R-21
Partition (2x6'16)
MASTER
SUITE
Wall
12
O'057
IS
90
Yes
R-21
Partition (2x6.16)
MASTER
SUITE
Roof
713
0'030
240
0
Yes
Built-up/R-38/Gypboard
MASTER
SUITE
COMPUTER METHOD SUMMARY C -2R, page 8 of 18
----------------------------------------------------------------------------
Project Name: LOT 72 ;Date: 7/19/199.5
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
PERIMETER LOSSES F2 Insulation
Type Length Factor R -Val Depth Location/Comments
ZONE NAME = FAU/CU/COIL 1
Covered S4.0 0.72 0.0 0 in LIV/DIN/KIT
Exposed S6.S 0.90 0.0 0 in LIV/GIN/KIT
Covered 43.5 0.72 0.0 0 in GUEST 1
Exposed 12.0 0.90 0.0 0 in GUEST 1
ZONE NAME = FAU/CU/COIL 2
Covered 86.0 0.72 0.0 0 in MASTER SUITE
Exposed 18.5 0.90 0.0 0 in MASTER SUITE
FENESTRATION SURFACES Sc
Act Glass
# Type Area Frame Div U -Val Azm Tilt Only Location/Comments
--------------- ----- ----- ---- ----- --- ---- ----- ---------------------
ZONE NAME = FAU/CU/COIL 1
1 Wdw Front (SW) 76.0 Vinyl No 0.50 240 90 0.52 LIV/DIN/KIT
2 Wdw Front (W) 24.0 None No 0.57 2.8S 90 0.65 LIV/DIN/KIT
3 Wdw Front (W) 128.0 Vinyl No 0.50 28S 90 0.S2 LIV/DIN/KIT
4 Wdw Front (W) 32.0 Vinyl No 0.52 285 90 0.52 LIV/DIN/KIT
5 Wdw Back (NE) 96.0 Vinyl No 0.50 60 90 0.52 LIV/DIN/KIT
6 Wdw Back (E) 24.0 Vinyl No 0.52 105 90 0.52 LIV/DIN/KIT
7 Wdw Right (S) 12.0 Vinyl No 0.52 19S 90 0.52 LIV/DIN/KIT
8 Wdw Right (S) 18.0 Vinyl No 0.52 195 90 0.52 LIV/DIN/KIT
9 Wdw Back (E) 32.0 Vinyl No 0.52 105 90 0.52 GUEST 1
10 Wdw Back (E) 20.0 Vinyl No 0.S2 10S 90 0.52 GUEST I
11 Wdw Right (S) 48.0 Vinyl No 0.52 195 90 0.52 GUEST 1
ZONE NAME = FAU/CU/COIL 2
12 Wdw Front (W) 7.0 Vinyl No 0.52 285 90 0.52 MASTER SUITE
13 Wdw Front (W) 28.0 Vinyl No 0..52 285 90 0.52 MASTER SUITE
14 Wdw Left (N) 53.1 Vinyl No 0.52 0 90 0.S2 MASTER SUITE
.15 Wdw Right (SE) 64.0 Vinyl No 0.52 150 90 0.52 MASTER SUITE
16 Wdw Right (SE) 20.0 Vinyl No 0.S2 ISO 90 0.52 MASTER SUITE
17 Wdw Right (S) 64.0 Vinyl No 0.52 195 90 0.S2 MASTER SUITE
18 Wdw Right (S) 16.0 Vinyl No 0.52 195 90 0.52 MASTER, SUITE
INTERIOR. & EXTERIOR SHADING
# Type Interior Shade Type Sc Exterior Shade Type Sc
1 Wdw Std Drape 0.78 Standard Bug Screen 0.87
2 Wdw Std Drape 0.78 Standard Bug Screen 0.87
3 Wdw Std Drape 0.78 Standard Bug Screen 0.87
4 Wdw Std Drape 0.78 Standard Bug Screen 0.87
S Wdw Std Drape 0.78 Standard Bug Screen 0.87
6 Wdw Std Drape 0.78 Standard Bug Screen 0.87
7 Wdw Std Drape 0.78 Standard Bug Screen 0.87
8 Wdw Std Drape 0.78 Standard Bug Screen 0.87
9 Wdw Std Drape 0.78 Standard Bug Screen 0.87
10 Wdw Std Drape 0.78 Standard Bug Screen 0.87
11 Wdw Std Drape 0.78 Standard Bug Screen 0.87
12 Wdw Std Drape 0.78 Standard Bug Screen 0.87
13 Wdw Std Drape 0.78 Standard Bug Screen 0.87
14 Wdw Std Drape 0.78 Standard Bug Screen 0.87
15 Wdw Std Drape 0.78 Standard Bug Screen 0.87.
16 Wdw Std Drape 0.78 Standard Bug Screen 0.87
17 Wdw Std Drape 0.78 Standard Bug Screen 0.87
18 Wdw Std Drape 0.78 Standard Bucy Screen 0.87
COMPUTER METHOD SUMMARY C -2R page 9 of 18
---------------------------------------------------------------------------
Project Name: LOT 72 ;Date: 7/19/1995
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
OVERHANGS/SIDE FINS
-----Overhang------
Len Ht LExt RExt
.13.5 1.0 13.5 13.5
13.5 1.0 13.S 13.5
6.S 1.0 6.5 6.S
---Left Fin--- ---Right Fin --
Dist Len Ht Dist Len Ht
---- ---- ---- ---- ---- ----
THERMAL MASS
--Window--
# Type.
Ht
Wd
3 Wdw
8.0
8.0
4 Wdw
8.0
4.0
17 Wdw
8.0
8.0
-----Overhang------
Len Ht LExt RExt
.13.5 1.0 13.5 13.5
13.5 1.0 13.S 13.5
6.S 1.0 6.5 6.S
---Left Fin--- ---Right Fin --
Dist Len Ht Dist Len Ht
---- ---- ---- ---- ---- ----
THERMAL MASS
Area Thick Heat
Inside Location
Type
(sf) (in) Cap Cond Form 3 Reference
---- ----- ----- ---------------------------
R -Val. Comments
------ --------
-------------
ZONE NAME =
FAU/CU/COIL 1
Covered Slab
700 3.50 28 0.98 n/a
2
Exposed Slab
768 3.50 28 0.98 n/a
0
Covered Slab
340 1.50 28 0.98 n/a
2
Exposed Slab
2S 3.50 28 0.98 n/a
0
ZONE NAME =
FAU/CU/COIL 2
Covered Slab
S93 3.50 28 0.98 n/a
2
Exposed Slab
120 3.50 28 0.98 n/a
0
HVAC SYSTEMS
Minimum Distrib Type Duct TStat
System Type
Efficiency and Location RVal Type
---------------- ---- ------
Location/Comments
-----------------------
----- - -----
Furnace
----------
0.801 AFUE Ducts in Attic 4.2 SetBck
FAU/CU/COIL-
1
SpltAirCond12.1S0
SEER Ducts in Attic 4.2 SetBck
Furnace
0.801 AFUE Ducts in Attic 4.2 SetBck
FAU/CU/COIL
2
SpltAirCond12.0S0
SEER Ducts in Attic 4.2 SetBck
Water
No.
Tank Ext.
WATER HEATING
SYSTEMS Heater
in
Energy Size Insul
System Name
Distribution Type Type
--------
Sys
----
Factor (gal) R -Val
------ - ---- -----
------------------------
AMERICAN APP
------------------
G52-SOT38- Pipe Insulation StorGas
1
0.60 50.0 0.0
AMERICAN APP
GS2-50T38-- Recirc-Time&Temp StorGas
1
0.60 SO.0 0.0
AFUE
WATER HEATER
EQUIPMENT DETAIL /Rec Rated
Stdby
Tank Pilot
System Name
System Type Eff Input
Loss
R -Val Light
AMERICAN APP
GS2-50T38- DomesticHW 0.760 38000
0.000
16.0 0
AMERICAN APP
G52-SOT38- DomesticHW 0.760 38000
0.000
16.0 0
SPECIAL FEATURES/REMARKS
V.A.V.TO GUEST 1
A Zonally Controlled HVAC System which meets CEC criteria has been assumed
HVAC ZONE HEATING & COOLING LOAD SUMMARY page 10 of 18
Project Name: LOT 72 ;Date: 7/19/1995
Documentation: KROWN MECHANICAL_ DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
HVAC ZONE DESCRIPTION
HVAC Zone Name: FAU/CU/COIL 1
Heating System Name: LENNOX 80MGF4/5-12OA-**
Cooling System Name: LENNOX HS2S-651/C22-65
System Multiplier: 1
Fan Schedule: 24 Hr Fans STD
Peak Load Method: COINCIDENT
Relative Humidity: 50
NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will heat or cool this zone during_ the design conditions indicated.
These numbers include no safety factor, and the HVAC contractor should
oversize by a reasonable°margin to account for variations in weather
conditions and the pick-up capacity required to bring the zone to temper-
ature as a result of a setback thermostat. Those responsible for final
equipment selection should note that Sensible and Latent Cooling Loads are
indicated to allow for accurate comparison with manufacturer's output data.
COOLING
SPACES IN THIS
ZONE PEAK
HEATING
PEAK. SENSIBLE
LATENT
LIV/DIN/KIT
(Jan
12am)
25589
(Aug 2pm) 28152
-811
GUEST 1
(Jan
12am)
7258
(Aug 2pm) 7185
-90
TOTAL SPACE
LOAD
32847
35337
-901
Duct Gains &
Losses:
3285
3534
Ventilation:
( 10 CFM)
0
0
0
Return Air Lighting
Gain
-------
0
--------
------
TOTAL. SYSTEM
LOAD
36132
38871
-901
SYSTEM OUTPUT
AT DESIGN CONDITIONS
98377
44168
10459
NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will heat or cool this zone during_ the design conditions indicated.
These numbers include no safety factor, and the HVAC contractor should
oversize by a reasonable°margin to account for variations in weather
conditions and the pick-up capacity required to bring the zone to temper-
ature as a result of a setback thermostat. Those responsible for final
equipment selection should note that Sensible and Latent Cooling Loads are
indicated to allow for accurate comparison with manufacturer's output data.
RESIDENTIAL SPACE HEATING LOAD -SUMMARY page 11 of 18
Project Name: LOT 72 ;Date: 7/19/199.5
Documentation: KROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
Space Name: LIV/DIN/ITT
Design Indoor Dry Bulb Temperature:
70 F
Design Outdoor Winter Dry Bulb
Temperature:
32 F
Design Temperature Difference:
38 F
Conduction
Area
U -Value
TD
Btu/hr
R-21 Wall (W21.2x6.16)
927.0
x
.0.0596
x
38.0 -
2098
Solid Wood Door
48.0
x
0.3872
x
38.0 -
706
Low E Brnz Default (R))
96.0
x
0.5000
x
38.0 =
1824
Low E Brnz Default (R)j
24.0
x
O.S200
;x
38.0 =
474
Low E Brnz Default (R))
30:0
x
0:5200
x
38.0
= 593
Low E Brnz Default (R))
76.0
x
0.5000
x
38.0 =
1444
Low E Brnz Default (R))
128.0
'x
O.SO00
x
38.0
= 2432
Low E Brnz Def au 1 t , ( R) )
32.0
x
0 . 5200
x
38.0
= 632
Decora Glass Block (R)
24.0
x
0.5700
x
38.0
= S20
Built-up/R-38/Gypboard
47.0
x
0.0296
x
38.0
= S3
Tile/R-38/Gypbd
1121.3
x
0.0294
x
38.0
= 1254
Slab on.Grade
Perim =
54.0
x
42
= 2241
Slab on Grade
Perim =
S6.S
x
42
= 2345
Infiltration: 1.00 x 0.018 x
1468 sf
x 12.0
ft
x 0.75 AC
x
38.0
= 8973
TOTAL
HOURLY
HEAT
LOSS FOR
SPACE
25589
Heating AirFlow: 25589 Btu/hr
/
[1.07 x
35
F DeltaT)1
= 682
cfm
� RESIDENTIAL SPACE COOLING LOAD SUMMARY page 12 of 18
. -'-------------_---------__-_-----___----_----__---_---__--_-___----_--_
---_
ProJeot Name: LOT 72 !Date: 7/19/1995
/
'
Documentation: KROWN MECHANICAL DESIGN :COMPLY 24 User 2366
---------------------------------------------------------------------------
Spaoe Name:
LIV/DIN/KIT
Design Indoor Dry
Bulb Temperature:
78 F
Design Outdoor Summer
Dry Bulb Temperature:
112 F
Design Temperature
Difference:
'
34 F
Conduction
Area
U -Value
_______
DETD
____
Btu/hr
------
_______________________
R-21 Wall (W21'2x6'16)
______
927'0
x 0'0596
x
27.6
1524
Solid Wood Door
48'0
x 0'3872
x
27'6 =
513
Low E Brnz Default
(R))
96'0
x 0'5000
x
34.0 �
1632
Low E Brnz Default
(R))
24'0
x O'5300
x
34'0
424
Low E Brnz Default
(R))
30'0
x 0'5200
x
34'0
530
Low E Brnz Default
(R)l
76,0
x 0'5000
x
34'0
1292
Low E Brnz Default
(R))
l28'0
x 0'5000
x
34'0
2176
Low E Brnz Default
(R))
32'0
x 0'5200
x
34'0
566
Deoora Glass Block
(R)
24'0
x 0'5700
x
34'0
465
Built-up/R-38/Gypboard
47'0
x 0'0296
x
48'0
67
Tile/R-38/Gypbd
1121'3
x 0'0294
x
48'0 =
1584
Infiltration: l'OO
x 0.018 x 1468 sf
x 12'0 ft
x 0'75 AC
x
34'0
8028
~ Shaded Unshaded
Solar Gain Orient' Area 8GF Area SGF SC
----------------------- --------- ---- --- ---- --- ----
Low E Brnz Default (R)) Southwest [ 0'0 x IS + 76'0 x 621 x 0'38 =
Deoora Glass Block (R) West [ 0'0 x IS + 24'0 x 731 x O'59 =
Low E Brnz Default (R)) West [ 128'0 x IS + O'O x 731 x 0'38 =
Low E Brnz Default (Rl) West [ 32'0 x IS + O'O x 731 x 0'38 =
Low E Brnz Default (R)) Northeast [ 0'0 x IS + 96'0 x 481 x 0'38 =
Low E Brnz Default (R)) East [ 0'0 x IS f 24'0 x 731 x 0'38 �
Low E Brnz Default (R)) South [ 0'0 x 15 + 12'0 x 321 x 0'38 �
Low E Brnz Default (R)) South [ 0'0 x IS + 18'0 x 32] x 0'38 �
Internal 'Gain Op Frac. Area Heat Gain Conv'
----------------------- -------- ------ --------- -----
Lighting l'OO x 1468.3 x 0`200 x 3'413 =
Equipment 1'00 x 1468'3 x 0'100 x 3'413 �
Occupants l'OO x 1468'3 x 22S / 333 �
TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE
Latent Gain Op Frac. Area Heat Gain Conv'
Equipment 1.00 x 1468'3 x 0'000 x 3'413
Occupants 1'80 x 1468'3 x 22S / 333
Infiltration: l'OO x 0'018 x 1468 af x 12'0 ft x 0'75 AC x -7'0
TOTAL HOURLY LATENT HEAT GAIN FOR SPACE
1792
1041
730
183
l7S3
666
146
219
1002
501
992
------
28152
Btu/hr
Cooling AirFIow: 28152 Btu/hr / [1'07 x 23 F DeltaT)] = 1142 ofm
RESIDENTIAL SPACE HEATING LOAD SUMMARY page 13 of 18
Project Name: LOT 72 ;Date: 7/19/1095
Documentation: YROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
Space
Name:
GUEST
1
Design
Indoor Dry Bulb Temperature:
70
F
Design
Outdoor Winter Dry Bulb Temperature:
32
F
Design
Temperature Difference:
38
F
Conduction
R-21 Wall (W21.2x6.16)
R-21 Partition (2.x6.16)
Low E Brnz Default (R))
Low E Brnz Default (R))
Built-up/P.-38/Gypboard
Slab on Grade
Slab on Grade
Infiltration: 1.00 x 0.018 x
Heating AirFlow: 7258 Btu/hr /"[1.07 x 35 F DeltaT).] = 193 cfm
Area
U -Value
TD
Btu/hr
328.0
x
O.OS96
x
38.0
= 742
70,.0
x
0.0574
x
38.0
- 153
52.0
x
0.5200
x
38.0
= 1028
48.0
0.5200
x
38.0
= 948
365.0
x
0.0296
x
38.0
- 411
Perim =
43.5
x
42
= 1805*
Perim =
.1.2.0
x
42
= 498
365 sf
x 9.0
ft
x 0.7S AC
x
38.0
= 1673
TOTAL
HOURLY
HEAT
LOSS FOR
SPACE
7258
Heating AirFlow: 7258 Btu/hr /"[1.07 x 35 F DeltaT).] = 193 cfm
RESIDENTIAL SPACE. COOLING LOAD SUMMARY page .14 of 18
-------•--------------------------------------------=--------------------
---
Project Name: LOT 72 ;Date: 7/.19/199.5
I
Documentation: KROWN MECHANICAL DE -SIGN ;COMPLY 24 User 2366
----------------------------------------------------------------------------
Space Name:
GUEST 1
Design Indoor Dry Bulb
Temperature:
78 F
Design Outdoor Summer Dry
Bulb Temperature:
112 F
Design Temperature Difference:
34 F
Conduction
Area
------
U -Value
-------
DETD
----
Btu./hr
------
------------------------
R-21 Wall (W21.2x6.16)
328.0
x
0.0596 x
27.6 =
539
R-21 Partition (2x6.1.6)
70.0
x
0.0574 x
27.6 =
111
Low E Brnz Default (R))
52.0
x
0.5200 x
34.0 =
919
Low E Brnz Default (R))
48.0
x
0.5200 x
34.0 =
849
Built-up/R-38/Gypboard
365.0
x
0.0296 x.
48.0 =
519
Infiltration: 1.00 x 0.018
x 365
sf x 9.0 ft
x 0.75 AC x
34.0 =
1497
Shaded
Unshaded
Solar Gain
Orient.
Area SGF
---
Area SGF
---- ---
SC
----
-----------------------
Low E Brnz Default ( R) ,)
---------
East [
----
0.0 x 15
+
32.0 x 731
x 0.38
= 888
Low E Brnz Default (R))
East f
0.0 x 15
+
20.0 x 731
x 0.38
= S55
Low E: Brnz Default (R))
South (.
0.0 x 15
+
48.0 x 32)
x 0.38
= 584
Internal Gain
Op Frac..
Area
Heat
Gain
Conv.
Lighting
.1.00
x 365.0
x
0.200 x
3.413 =
249
Equipment
1.00
x 365.0
x
0.1.00 x
3.413 =
125
Occupants
1.00
x 365.0
x
22S /
333 -
247
TOTAL_ HOURLY
SENSIBLE HEAT
GAIN FOR SPACE
7185
Latent Gain
Op Frac.
Area
Heat
Gain
Conv,.
Btu./hr
Equipment
1.00
x 365.0
x
0.000 x
3.413 =
0
Occupants
1.00
x 365.0
x
225 /
333 =
247
Infiltration: 1.00 x 0.018
x 365
sf x 9.0 ft
x 0,.75 AC x
-7.0 -
-308
TOTAL HOURLY LATENT HEAT GAIN FOR SPACE -90
Cooling AirFlow: 7185 Btu/hr / [1.07 x. 23 F DeltaT).] = 291 cfm
HVAC ZONE HEATING & COOLING LOAD SUMMARY rage 15 of 18
_..--------------------------------•-------------------------------------------
Pro.ject Name: LOT 72 ;Date: 7/19/1995
Documentation: KROWN MECHANICAL DESIGN :COMPLY 24 User 2366
----------------------------------------------------------------------------
HVAC ZONE DESCRIPTION
HVAC Zone Name: FAU/CU%COIL 2
Heating System Name: LENNOX 80MGF2--45A-**
Cooling System Name: LENNOX HS25-261iC22-26
System Multiplier: 1
Fan Schedule: 24 Hr Fans STD
Peak Load Method: COINCIDENT
Relative Humidity: 50 0
COOLING
SPACES Iii THIS ZONE PEAK HEATING PEAK SENSIBLE LATENT
----------------------- ----------- ------------ ------
MASTER SUITE (Jan 12am) 16432 (Aug. 2pm) 16017 -3S7
TOTAL- SPACE LOAD 16432 16017 -3S7
Duct Gains & Losses: 1643 1602
Ventilation: ( 0 CFM) 0 0 0
Return Air Lighting Gain 0
TOTAL- SYSTEM LOAD .18075 17619 -357
SYSTEM OUTPUT AT DESIGN CONDITIONS 36903 18240 3794
NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will heat or cool this zone during_ the design conditions indicated.
These numbers include no safety factor, and the HVAC contractor should
oversize,by a reasonable margin to account for variations in weather
conditions and the pick-up capacity required to bring the zone to temper-
ature as a result of a setback thermostat.. Those responsible for final
equipment selection should note that Sensible and Latent Cooling Loads are
indicated to allow for accurate comparison with manufacturer's output data.
RESIDENTIAL SPACE HEATING LOAD SUMMARY
page 16'of 1.8
-----------------------------------------------------------
Project Name: LOT 72
-
;Date:
7/19%1995
Documentation: KROWN MECHANICAL DESIGN
-----------------------------------------7-----------------------------------
;COMPLY
24 User
2366
Space Name:.
MASTER
SUITE
Design .Indoor Dry Bulb Temperature:
70 F
Design Outdoor Winter Dry Bulb Temperature:
32 F
Design Temperature Difference:
38 F'
Conduction
Area
U -Value
TD
Btu/hr
R--21 Wall (W21.2x6.16)
766.9
x
0.0.596
x
38.0 =
1736
R-2.1 Partition ( 2x6.16)
183.5
x
0:0574
x
38.0 =
401
Low E Brnz Default (R))
53.1
x
0.5200
x
38.0 =
1049
Low E. Brnz Default (R) )
84.0
x
O . S200
x.38.0
=
1660
Low E Brnz Default (R))
16.0
x
0.5200
x,
38.0 =
316
Low E Brnz Default (R A
64.0
x
0.5200.
x
38.0 =
1265
Low E Brnz Default (R)'')
35.0
x
0.5200
x
38. 0 -
692
Built--up/R-38/Gyoboard
713.0
x
0„0296
x-38.0
=
802
Slab on Grade Perim =
86.0
x
42 =
3569
Slab on Grade Perim =
18.5
x
42 -
768
Infiltration: 1.00 x0.018 x 713 sf
x 11..5
ft
x 0.75 AC
x
38.0 -
4175
TOTAL
HOURLY
HEAT
LOSS FOR
SPACE
16432
Heating AirFlow: 16432 Btu/hr /.(1.07
x'
35
F DeltaT)_1
=
438
cfm
RESIDENTIAL SPACE COOLING LOAD SUMMARY page 17 of 18
Project Name: LOT 72 ;Date: 7/.19/1995
Documentation: <ROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
------------------ --------------------------------------------------------
Space Name:
MASTER SUITE
Design Indoor Dry Bulb
Temperature:
78 F
Design Outdoor Summer Dry
Bulb Temperature:
112 F
Design Temperature
Difference:
34 F
Conduction
Area
U -Value
-------
DETD
----
Btu/hr
------
-----------------------
R-21 Wall (W21.2x6.16)
------
766.9
x
0.0596 x
27.6 =
.126.1
R-21 Partition (2x6.16)
183.5
x
0.0574 x
27.6 =
291
Low E Brnz Default
(R)')
53.1
x
0.5200 x
34.0 =
939
Low E Brnz Default
(R))
84.0
x
0.5200 x
34.0 =
1485
Low E Brnz Default
(R))
16.0
x
0.5200 x
34.0 =
283
Low E Brnz Default
(R.) )
64.0
x
0.5200 x
34.0 -
1132
Low E Brnz Default
( R))
3S.0
x
0 . 5200 x
34.0 -
619
Built-up/R-38/Gypboard
713.0
x
0.0296 x
48.0 -
1013
Infiltration: .1.00
x 0.018
x 713
sf x 1.1.5 ft
x. 0.75 AC x
34.0 =
3736
Shaded
Unshaded
Solar Gain
Orient.
Area SGF
Area SGF
---
Sc
----
-----------------------
Low E Brnz Default
(R))
---------
West
---- ---
0.0 x 15
+
----
7.0 x 731
x 0.38
= .194
Low E Brnz Default
( R) ,)
West
0.0 x 15
+
28.0 x 73.1
x 0.38
= 777
Low E Brnz Default
(R))
North f
0.0 x 15
+
S3..1 x 151
x 0.38
= 303
Low E Brnz Default
(R))
Southeast [
0.0 x 15
+
64.0 x 621
x 0.38
= 1509
Low E Brnz Default
(R))
Southeast. f
0.0 x 15
+
20.0 x 621
x 0.38
= 472
Low E Brnz Default
(R))
South (
64.0 x. 15
+
0.0 x 321
x 0.38
= 36S
Low E Brnz Default
(R))
South [
0.0 x IS
+
16.0 x 321
x 0.38
= 195
Internal Gain
Op Frac.
Area
Heat
Gain
Conv.
Lighting
1,.00
x 713.0
x
0.200 x
3.413 =
487
Equipment
1.00
x 713.0
:<:
0.100 x
3.41.3 -
243
Occupants
.1.00
x 7.13.0
x
225 /
333 =
482
TOTAL HOURLY
SENSIBLE HEAT
GAIN FOR SPACE
16017
Latent Gain
Op Frac.
Area
Heat
Gain
Conv.
Btu/hr
Equipment
1.00
x 713.0
x
0.000 x
3.413 =
0
Occupants
1.00
x 713.0
x
225 /
333 =
482
Infiltration: 1,.00
x 0.018
x 713
sf x 11.S ft
x 0.75 AC x
-7.0 =
-770
TOTAL HOURLY LATENT -TEAT GAIN FOR SPACE -357
Cooling AirFlow: 16017 Btu/hr / (1.07 x 23 F DeltaT)1 = 650 cfm
INSTALLATION CERTIFICATE CF -6R page 18 of 18
• ---------------------------------------------------------------------------
Project Name: LOT 72 ;Date: 7/19/199.5
Documentation: YROWN MECHANICAL DESIGN ;COMPLY 24 User 2366
---------------------------------------------------------------------------
I, the undersigned, verify that the equipment listed in the category above
illy signature is the actual equipment installed and that the equipment
meets or exceeds the requirements of the Appliance Efficiency Standards.
In addition, I have verified that the equipment is equivalent to or more
efficient than the equipment specified on the Certificate of Compliance
submitted to demonstrate compliance with the Energy Efficiency Standards
for residential buildings.
HVAC SYSTEMS
Heat. Equip CEC Certified Manuf. Actual Distrib Type Duct Heat Heat
System Type Make & Model Number Eff. .and Location RVal Load Output
------------ --------- - ------------- ------------------- ---- ------ ------
Furnace LENNOX 80MGF4/S-12OA-** 0.801 Ducts in Attic 4.2 36132 98377
Furnace LENNOX 80MGF2145A-** 0.801 Ducts in Attic 4.2 18075 36903
Cool. Equip CEC Certified Manuf. Actual Distrib Type Duct
System Type Make & Model Number Efficiency andLocation RVal
SpltAirCond LENNOX HS2S-651/C22-6S 1.2.150 SEER Ducts in Attic 4.2
SpltAirCond LENNOX HS2.5-26l/C22--26 1"2.050 SEER Ducts in Attic 4.2
Signature Date Name
Water No. Tank Ext.
WATER HEATING SYSTEMS Heater in Energy Size Insul
CEC Cert. Make & Model Distribution Type Type Sys Factor'(gal) R -Val
AMERICAN APP GS2-SOT38- Pipe Insulation StorGas 1 0.60 50.0 0.0
AMERICAN APP GS2••-50T38- Recirc-Time&Temp StorGas 1 0.60 50.0 0.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot
System Name System Type Eff Input Loss R -Val Light
AMERICAN APP G52-SOT38- DomesticHW 0.760 38000 0.000 16.0 0
AMERICAN APP G52-.5GT38- DomesticHW 0.760 38000 0.000 16.0 0
FAUCETS & SHOWER HEADS:
All faucets and showerheads are listed in the Commissions Directory Of
Certified Faucets And Showerheads, pursuant, to Title 24, Part 6,
Subchapter 2, Section Ill.
Signature Date Name
DESERT SANDS UNIFIED SCHOOL DISTRICT
82-879 Highway 111
NOTICE: Indio, CA 92201
Document Cannot Be Duplicated 619-775-3500
Date 110/17/951 Type of Permit La Quinta
No. 113768 1 Permit #
Owner Name La Quinta Golf Properties Log
No. 79480 Street Tom Fazio Lane North
City La Quinta Zip 92253 Study Area 108
APN # 761-521-002 Tract # 128189 Lot # 0 Square Footage 12546
Type of Development I Single Family Residence No. of units 0
Comments
At the present time, the Desert Sands Unified School District does not collect fees on
garages/carports, covered patios/walkways, residential additions under 500 square feet,
detached accessory structures or replacement mobilehomes. It has been determined
the above-named owner is exempt from paying school fees at this time due to the
following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to Government Code 53080
in the amount of 1.72 x 2 546 or $ 4,379.12 have been paid to D.S.U.S.D. for
the property listed above and that building permits and/or Certificates of Occupancy for
this square footage in this proposed project may now be issued.
Fees Paid By La Quinta golf Propertiesd, Inc. Telephone 777-110`0
Name on the check
By Dolores A. Ballesteros 1'=
Superintendent
Fee collected /exempted by Pauline Pearson
Payment Received
Signature
$4,379.12 Check No. 23309
Collector: Attach a copy of county or city plan check application form to district copy for all waivers.
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting