Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-3899 (SFD)
z � • P.O. BOX 1504 �^� VOICE 760 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY, DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 9/06/05 Application Number: 05-00003899 , Owner: Property Address: 61150 -`TOPAZ 'DR SHEA LA QUINTA APN: 764-270-999-67 -300234- C/O JEFF MCQUEEN Application description: DWELLING - SINGLE FAMILY DETACHED 8800 N GAINEY CENTER 350 Property Zoning: MEDIUM HIGH DENSITY RES SCOTTSDALE, AZ 85258 Application valuation: 142817 Contractor: D e Applicant:rchitect or Engineer: n SHEA HOMES, INC. Y1 `-zx\c 1 81260 AVENUE 62 OCT 9 4 2005 YT LA QUINTA, CA 92253 ll 1 (760)777-6005 Lic. No.: 672285 WY®F=10'NTA PIMAl11 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjur hat I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the 8 in and Professions Code, and my License is in full force and effect. License Clasp:, � B ense No.: 672285 Bate: v ractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of .the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ,41 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier AMERICAN HOME Policy Number 1247619 I certify that, in the performance of the work fo which this permit is issued, I shall not employ any person in any manner soAs to come subi t to the workers' compensation laws of California, 4�10agoree that,if I shout e e subject [ the workers' compensation provisions of Section abor Co , I II orthwith mply with those provisions. Yate: t: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,0001. IWADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this applic tion becomes nulla d void if work is not commenced within 180 days from date of issuance o uch permit, or ces ation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state 9thate ab a informa n is correct. I agree to comply with all city and co ty ordi nces and state laws relatingI onstructi a presentatives of this c un o ent r u e above-mentionedty fo in e n rposes. pafe: S re (Applicant or en Application Number . . . 05-00003899 LQPERMIT Structure Information Construction Type . . . . . TYPE V - NON RATED. Occupancy Type . . . . . . DWELLG/LODGING/CONG <=10 Flood Zone NON -AO FLOOD ZONE Other struct info CODE EDITION 2001 CBC FIRE SPRINKLERS NO GARAGE SQ FTG 562.00 PATIO SQ FTG 457.00 NUMBER OF UNITS 1.00 --------------------------------- 1ST FLOOR SQUARE FOOTAGE ------------------------------------------- 1556.00 Permit . . .. BUILDING PERMIT Additional desc . Permit Fee . . . . 790.00 Plan Check Fee 513.50 Issue Date . . . . Valuation . . . . 142817 Expiration Date 3/05/06 Qty Unit Charge Per Extension BASE FEE 639.50 43.00 3.5000 -----------------------------------------------------------=---------------- THOU BLDG 100,001-500,000 150.50 Permit . . . MECHANICAL Additional desc . Permit Fee . . 77.00 Plan Check Fee 19.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/05/06 Qty Unit Charge. Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 9.0000 EA ' MECH B/C <=3HP/100K BTU 18.00 3.00 6.5000 EA MECH VENT FAN 19.50 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee 80.70 Plan Check Fee 20.18 Issue Date . . . Valuation 0 Expiration Date 3/05/06 Qty Unit Charge Per Extension BASE FEE 15.00 1556.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 54.46 562.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 11.24 LQPERMIT Application Number . . . . . 05-00003899 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 123.00 Plan Check Fee 30.75 Issue Date Valuation 0 Expiration Date 3/05/06 Qty Unit Charge Per Extension BASE FEE 15.00 9.00 6.0000 EA PLB FIXTURE 54.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER-INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 6.00 .7500 EA PLB GAS PIPE >=5 4.50 1.00 .15.0000 -------=-------------------------------------------------------------------- EA PLB GAS METER 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 - Issue Date . . . . Valuation . . . . 0 Expiration Date 3/05/06 Qty' Unit Charge Per Extension BASE FEE 15.00 -----------------------------------------------------=--------- Special Notes.and Comments ------------- SFD - LOT 67 PLAN 4510B, 1556 SF (26 SF.BOX BAY @MBR, 83 SF GAR. EXT. 120 SF PATIO EXT.PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA OR DRIVEWAY APPROACH ------------------------------------------ Other Fees . . . . . ---------------------------------- . . . . ART IN PUBLIC PLACES -RES ..00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 51.35 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE :00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 5.02.00 STRONG MOTION (SMI) - RES 14.28 DIF STREET MAINT FAC -RES 15.00 .,DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited Due LQPERMUf Application Number 05-00003899 ----------------- ---------- Permit Fee Total 1085.70 ---------- ----- .00 ----- ---------- .00 1085.70 % Plan Check Total 583.68 .00 .00 583.68 Other Fee Total 2470.63 .00 .00 2470.63. Grand Total 4140.01 _ .00 .00 4140..01" LQPERMTT MAR 20,2006 12:59 BCI*TESTING,ri1 000-000-00000 Page 6 CF -4R CERTIFICATE OF FIELD VERIFICATION A DIAGNOSTIC TESTING March, 20 2006 This CF -411 Issued by CalCERTS@ is for the home located at: 61150 Tnpat Drive La Quinta CA, 9225.3 Certificate Number: CC3-1798358265 Date Inspected: March, 15 2006 Ca10ERTS Rater: William Henson ested Duct Design Compliance: CC2004076 ` HERS Analyst: N/A z 1: Builder/ Developer: Shea Homes, Inc. yC Project: Trilogy (al La Quinta Phase: Phase 13A 1 elan Name: 4510 i Lot Number: 067 Specifics about this home: General Information Conditioned Floor Area: 1700 Square Feet Conditioned Volume: 0 Cubic FCCt Front Orientation: N/A Number of Stories: i Heating and Cooling Systems Heating Equipment: Furnace: 0.8 Cooling Equipment: AC: 12 HVAC Air Distribution Duct Location: Attic Duct Leakage Target: 6.0 Duct Insulation R -Value: 6 Air Infiltration Blower Door Target: 96 Water Heating S stein Pra used TY I Size I Fuel I EF Distribution Testing & Verification Results Main System HVAC System ested Duct Leakage- Ycns#N//A ested TXV: Yes ested Duct Design Compliance: ested Duct in Conditioned space; ested Reduced Dud Surface Area: N/A Rested Infiltration Reduction Credit: NIA Tested Approved As Part Of Sample Group BCI Testing - 77 -760 Country Club Drive Suite I Palm Desert, CA. 92211 760-772-295 . Water 11cating System Actual Certifying ,.;';;::::tt:re Date TY I Size...J. Fuel I EF I Distribution The energy efficiency rating of this home is determined using California dome Energy Rating System (C -HERS) rules. 'rhe rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verified and approved by the CdlCtRTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in ohtaininq it, you may Contact: CaICERTS -- Customer Service 11 Natoma St Suite 140, tolsom, CA 95630. 03/02/2006 16:55 FAX PARAGONPSCHIMID IaOO2/007 . INSULATION CERTIFICATE This is to certify that insulation has been installed in conformance with the current energy regulation, California Administrative Code, Title 24, State of California, in the building at 61-150 TOAZ DR, LOT 4067, PHASE 13A, LA QUINTA, CA CEILINGS: TYPE: BLOW MANUFACTURER: Cacoon Stable THICKNESS: R-38 WALLS: TYPE: BAITS MANUFACTURER: Cacoon.Borate THICKNESS: W-13 GENERAL CONTRACTOR: SHEA HOMES LICENSE # BY, TITLE: PARAGON SCHMID BUILDING PRODUCTS A MASCO Company LICENSE # 221517 f' BY. TITLE: ACCOUNT REPRESENTIVE DATE:"we (' JCM Inspections Lm% 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA IBC ❑Title 24 Other: Client: Sub-Contractor: Shea La Quinta, LLC DCCCC General Contractor: Architect: Structural Engineer: Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi Slump (inches): I=,;—. ,.» Supplier: Superior Time Sampled: �. Mix Design: D83625P Time in Mixer (min.): Specified Strength (PSI): 4000 Water Added @ Jobsite (gals.): Addmixture: POZZ 322N' Concrete Temperature (F): Truck #: 7� 1 „ Ticket #: LA („3 L4 Ambient Air Temperature (F): �,t” Field ID Marking: S-e-t�A -' 4 cylinders �- Weather: Unresolved Items: © None E] See Below Location of Sample: S1 A=� 6 rn C" c n tic. — t CA') P ✓1 ❑ No Samples Taken Description of Work Inspected: Phase .N Lot# Ll Product I Plan 4S' oJes n — sn Tt,0n'2s 6rIN10 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1), Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional rebar placed as per these details and as noted on r� \.;,A,, 0 r,, A A � �. ; .. 1 6f ., AL� ' •, �, �.� L' �� .r a c� n n vrl� Also, typical details 2, 3/SD-1 and Notes on SN-1 apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were securely tied and supported off the earth. Accepted for concrete placement. 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes. 1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx 'Z, Verified correct mix design. I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: JacWC. Millin ICC Certificaiio t�No: 0842216-80 0 , c—, - Contr&ctoes ge . res ntative: I ',t1JL ) V I Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Go ing Agency Page 1 of em Ar JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTION'S Phone: 760=345-5554 - Fax: 760-772-3895 INSPECTIONS, COMPRESSION STRENGTH TEST. RESULTS Client: Shea La Quinta, LLC Date: 3112106 Project: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 81-260 Avenue 62 La Quinta, CA 92274 ` Set ID Structure Age of Test Compression Strength JCM ID Location Date Cast Cylinder ID (days) (psi) Set A Phase 13A - Lot # 4067 Slab on Grade 11-23-05 Concrete 273-633 Kitchen Required psi: 4000 1869 7 3560 1870 28 5020 1871 28 5060 CERTIFIED: JCM Inspections supplies the service of compression strength test results only. Per ASTMC39 Page 1 of 1 C., } Copy 1 JCM n'spections Copy 2 Project Superintendent Copy 3 Governing Agency Page f of r JCM Inspections 39725 Garand Lane Suite F 1 Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: Z✓ IBC 81-260 Avenue 62 La Quinta, CA Title 24 Client: Sub -Contractor: Shea La Quinta, LLC Sun Coast Tensioning Other: General Contractor: Architect: Structural Engineer: Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi Weather: Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons Sit t V% (%I A Unresolved -litems: Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips psi to 33.04 kips/33,000 lbs 4:71 aJ None ❑ See Below Calibration Date: Machine #-:x,,-7. Phase.. k Lot# A Productt Plan Description of Work Inspected: Actual Elongation (in) Specified Complies within 7% +/- of specified elongation. Lot # Location Tendons Elongation (in) Reference 11h/SN2. Yes No �..,' � .... ' `^'� It C i- ..�n � � ', R � 1 � � � © ❑ _ El 0 ❑ o - -�- _� _ ' 3 1 0- El ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications applicable building laws. Final report issued at project completion. Inspector: Jack C. Millin ICC Certification No:0842216-89 Contractoes�Represeritative: C., } Copy 1 JCM n'spections Copy 2 Project Superintendent Copy 3 Governing Agency Page f of r