Loading...
BRES2014-1162'78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T4ht 4 4 QuAt DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/27/2017 Permit Type/Subtype: BUILDING RESIDENTIAL/REMODEL Owner: Application Number: BRES2014-1162. LARRY ESPINOLA Property Address: 78743 TUJUNGA 78-743AVENIDA TUJUNGA APN: 770093004 LA QUINTI, CA 92253 Application Description: RELOCATE LAUNDRY ROOM, NEW SLIDER AND NEW CLEARSTORY Property Zoning: Application Valuation: $35,000.00 Applicant: Contractor: OSMOND CONSTRUCTION COMPANY OSMOND CONSTRUCTION COMPANY 0 OUTSIDE CITY LIMITS 0 OUTSIDE CITY LIMITS LA QUINTA, CA 92253 LA QUINTA, CA 92253 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: _ License No.: :LIC -0003479 Date Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec: 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does'the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If„however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Add (760)559-7080 Llc. No.: :LIC -0003479 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. - . ” I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I . shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to buildirig construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Date: Signature (Applicant or Agent): FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT HOURLY PLAN CHECK - YES 101-0000-42600 1.25 $87.50 Total Paid for BLDG CITY STAFF - PER HOUR: $87.50 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $24.17 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $24.17 Total Paid for ELECTRICAL: $48.34 DESCRIPTION ACCOUNT QTY AMOUNT. APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $4.83 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $4.83 Total Paid for MECHANICAL: $33.84 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $24.17 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 Total Paid for PLUMBING FEES: $84.62 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $21.75 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 .0' $134.88 Total Paid for REMODEL: $223.34 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308. v 0- • $4.55 * Total Paid for STRONG MOTION INSTRUMENTATION SMI: $4:55 , DESCRIPTION ; •ACCOUNT QTY AMOUNT i DOOR/WINDOW, REPLACE FIRST? 101-0000-42400' : 0 r $60191 ! DESCRIPTION : ACCOUNT QTY AMOUNT - DOOR/WINDOW, REPLACE, FIRST 7.PC 101-0000-42600'.1 0 $110.22. '- Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: ' s $171.13 TOTALS: $655.32 ` , J , 1 y •r` + c •. • - iii • � • • ir i �• Bfn. G OtY Of La Quinta Building 8r 5arety Division P.O. Box 1504,•78-495 Calle Tampico b.Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: YY le Owner's Name:. A. P. Number. U Address: e Legal Description: Contractor. �J S� City, ST, Zip: k-t Telephone:71 ProjeciDescripaon: Q X0, Address: (p I0 fir' City, ST, Zip: ,. 9aa C3 ` t lea rs r� Lie. #.: o? of ! City Lia CYC 01State Arch, Engr., Designer oop f Address: — _O ll City., ST, Zip:& BY1 Telephone: 603V4- :�fS k. Construction Type:. Occupancy: Project type (circle one): New Add'n Alter Repair Demo . Sq. FL: —� # Stories: #Units: r� Name of Contact Person r Telephone # of Contact Person:--71-v), % Estimated Value of Project 61940 APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd 'Rec'd TRACMG PERMIT FEES Plan Sets Plan Check submitted. 1:X Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit. . Truss Cates. Called Contact Person Plan Check Balance_ Title 24 Calci. 1hans picked up Construction Flood plain plan Plans resubmitted.. Mechanical Giading plan 2`d Review, ready for correc ' nskssue ` Electrical SubcontactorList Called Contact Person QJZJ PlumbingAJ N& a&5&&S Grant Deed Plans picked up S.M.L H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '^' Review; ready for correctionsPissae Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees rIL ' YO:UNG ENGINEERING SERVICES w v `• r 77-682 Country Club Dr. 'Ste.: B,.Palm Desert, CA 92211 ph (760) 772.5107 fax (760) 3457620 r •• a .� .•a •' n �. '}. . Letter of Transmittal To; -City of La Quinta Today's Date: 11'-24-14f' - 78=495 Calle Tampico ' City Due Date: 11-19-14 - La Quinta, CA 92253 Project Address: 78-743 Avenida Tujunga _ Attn: Kay } `Plan Check #:. BRES 2014=1.162 Submittal:.® 1st ❑ 4th F ❑ 2nd ❑ 5th ❑ ' 3'd ❑ Other: We are forwarding: ® By Messenger El By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: #'Of Descriptions: Includes: # Of Descriptions: + Copies: Copies: ® 1 Structural Plans ❑~ r ' Revised Structural Plans_ 1 Structural Calculations ❑ Revised Struct. Calcs +� Truss Calculations Floor " ❑ '% ' and.Roof El Revised Truss ❑ Soils Report ' p 7 Revised Soils Report ' ❑ Structu�A'CommenfList `. ❑ Approved Structural Plans~ ❑ Redlined Structural Plans y ❑ W App'roved,Structural Calcs ❑ Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss, Calcs._ ❑ ' . Approved Soils Report, ❑ Redlined Soils Reports - ❑ Other: Comments:'.'Structural content is approvable. _ = If you have any questions, please call.. Time = 1.25 HR ,. . Thi"s Mat6ri'aI SenVf,or. , .+�• ❑ Your Files.. ® Y Per Your Request ❑ Your Review ❑ Approval . ❑ CheckingQ At the request of r Other:"ED❑ `6 J. �4 . 4 , By: Kathryn Samuels ; nine► ® Palm Desert Office,: (760 ) •772=5107 ' • _ .' ; µ; Other: ❑ CITY OF-J r QUINTA ~ DEVELOP COMMUNI`(Y I IV BUILDING ENERGY'IANALYSIS`REPORT PROJECT: Remodel. Residence 78-734 Avenida Tujunga La Quinta, :CA 92253 Project Designer: r f Robert A. Pitchford Design .and Drafting 77-622 Country Club STE O . 5 Palm Desert, CA92211 ` (760) 346-2856 r } µ Report Prepared by: 1 Jon Scott ' • Scott Design and .Title 24, Inc, 77-085 Michigan Drive Palm Desert, CA 92211 , (760) 200=4780 Job Number: 'ECEIVE h NOV 0 5 2014 ' Date: TCW 11/4/2014. AIAANTA Fv�� AP'PROVE® The Energ'yFro computer program has been used to perform the calculations summarized in this Jimplianc— pofttrTtiis it g PLi�kdrs�� al and is authorized by the.California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy iciency Standards. ' This program developed by EnergySoft, LLC—www.energIsoft coir. �Z Z UHIC� Ene Pro 6.3 b Ene Soft.. User Number: 6712 ID:71 TABLE OF CONTENTS Cover .page Table of Contents 2 Form CF -1 R Certificate of Compliance 3 . Form RMS -1 Residential Measures 'Summary 11 Form MF -.1 R Mandatory Measures Summary 12 A ;t s j CITY OF LA QUIMTA LL3!LOING & SAFETY DEPT. ,PROVE® • FOR CONSTRUCTION , EnergyPro 6.3 by EnerSg oumbr:. serumer76712 ii CERTIFI.OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD • Project Name: Remodel Residence Calculation Date/Time: 08:52, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xml C*RF-01 Page 1 of 8 GENERAL INFORMATION g 01 Project Name Remodel Residence 0.00 w. 02 Calculation Description Title 24 Analysis 03 Project Location 78-734 Avenida Tujunga 04, CA City La Quinta 05' Standards Version Compliance 2015 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 45 12 Project Scope Addition and/or Alteration 13 Number of -Dwelling. Units 1 14 Total Cond. Floor Area (FT2) 2452 15 ,� Number of Zones 1 16 Slab Area (FT2) 2.452 17—( Number of Stories 1 18 Addition Cond. Floor Area 0 191 Natural Gas Available Yes 20 Addition Slab Area (FT2) 0 X21 Glazing Percentage (%) 14.1% COMPLIANCE RESULTS 01 Building Complies with Computer Performance . 02 This building incorporates features that require field testing 03 This building incorporates one or more Special Features sh( Reg 04 Energy Use (kTDV/ft2-yr) Space RTaitirl > SpacrCdol� _1 4AQ.Ve'ntWJio WRte�rieatin C_hotova` alc 0 Z T„QTAIL ai -10> M � z°0 o 7- t ation Number: ign nd/or erification by a certified HERS rater under the supervision of a CEC-approved HERS provider. vtelow ENERGY USE SUMMARY, 06 07 08 Proposed -Design Compliance Margin Percent Improvement 8.71 0.21 2.4% 263.70 0:81 .0:3% 0.00 0.00 0.0% 10.00 0.00 0.0% 0.00 0.00 — 282.41 1.02 0:4% e®� ��� Registration Date/Time: CA Building Energy EfficiencyStanddaa'r'ds - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated -at 2014-11-0408:53:35 g A 0264.51 n 0.00 w. 10.00 - set 283:43 ign nd/or erification by a certified HERS rater under the supervision of a CEC-approved HERS provider. vtelow ENERGY USE SUMMARY, 06 07 08 Proposed -Design Compliance Margin Percent Improvement 8.71 0.21 2.4% 263.70 0:81 .0:3% 0.00 0.00 0.0% 10.00 0.00 0.0% 0.00 0.00 — 282.41 1.02 0:4% e®� ��� Registration Date/Time: CA Building Energy EfficiencyStanddaa'r'ds - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated -at 2014-11-0408:53:35 CERTIFI40OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD • CI•RF-01 Project Name: Remodel Residence Calculation Date/Time: 08:52, Tue, Nov 04, 2014 Page 2 of 8 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xml REQUIRED SPECIAL FEATURES 'The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cooling Ventilation Fan . PROJECT'HERSFEATURES The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this -computer analysis. These, plus' any additional HERS features listed in the building components tables below, requre field verification by a certified HERS Rater. Building -level Verifications: • — None — Cooling System Verifications: • — None HVAC Distribution System Verifications: 4 Verified low -leakage ducts located entirety in -conditioned space Domestic Hot Water System Verifications: - None — .- v ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as d6mestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. • Reference Energy Use `� Energy.Design R.afing�t Margin Percent Improvement Total: Energy (kTDV/f2)` 327.82 ��' 326.80 r.� < 1.02 0.3% ` includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING FEATURE INFORMATION. . .9 01 02 '03 04 05 06 07 03 Number of Dwelling, 05 06 Number of Number of Water �rok"A�la� Conditioned Floor Area (sft) _ �� Units Number of Bedrooms Number of Zones Ventilation Cooling Systems Heating Systems I er�odel Residence W 2452 1 .3 1 1 1 ZONE INFORMATIQN r _ 01 'U T z 02 03 04 05 06 07 ) —n Zone Floor Area Avg. Ceiling one.Narn-9 Zone Type HVAC System Name (ft) Height Water Heating System 1. Water Heating System 2• Iafsidence- Conditioned HVAC1, 2452 16' DHW Sys 1 C rTj C �� Om� _ Z z'®A Registra io Number: zO Registration Date/Time: HERS Provider: in CA Buil Energy Efciencyot ads - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11-04 08:53:35 CERTIFI,OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD 0 Project Name: Remodel Residence Calculation Date/Time: 08:52, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xm1• CI•RF-01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04, 05 06 07 08. 09 16 Name Zone Construction Azimuth Orientation, Gross Area (ft2) Window and Door Area (ft2) Tilt(deg ) Status . Verified Existing 'Condition N Wall ex Residence R-13 Wall 0 315 1755 37 90 Existing No NE Wall ex Residence R-13 Wall 45 Front 200 48' 90 Existing No E Wall ex Residence R-13 Wall 90 45 1160 64.2 90 Existing. No S Wall ex Residence. R-13 Wall 180 135 1755 161.1 90 Existing No W Wall ex _. _ Residence _ R-93 Wall _ _ _ 270. [225.:_ 1.160 84 90 Existing,.: No _ Roof Residence Default prior To 1978 t*� 2452 Existing No vD ATTIC 01 02 03 04 05 06 09 10, 11 Verified 41 Roof Roof Radiant Existing Name Construction �� Roof Rise 'Reflectance Emittance Barrier Cool Roof Status Condifion Attic Attic Roof Cons �` 3 0.1 0.85 No No Existing No D C f 0> 0� ° - O 41�� 90 Cn 3> 4% o<T� � - z ® � Z tuilding tration Number: --� s Registration Date/Time: Energy Effia>cy tan ®dafds - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at 2014-i1-04 08:53:35• CERTIF10OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD 1* Project Name: Remodel Residence Calculation Date/Time: 08:52, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xml C*RF-01 Page 4 of 8 WINDOWS 01 02 03 04 05." 06 07 08 09 10 11 Name Side of Building Width(ft Height ) (ft) Multiplie r Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition ex 4x3 N Wall ex -- - 1 12.0 1.19 0.83 Insect Screen (default) Existing No ex 4x4 N Wall ex - - 1 16.0 1.19 0.83 Insect Screen (default) Existing No ex 2x3 N Wall ex -- -- 1 6.0 1.19 0.83 Insect Screen (default) Existing No ex 1x3 N Wall ex -- - 1 3.0 1.19 0.83 Insect Screen (default)' Existing No ex 2x3 2 E Wall ex - 1 6.0iSt, 1.19 0.83 Insect Screen (default) Existing No ex 2x3 3 E Wall ex -- -- 1 X07 1.19 0.83 Insect Screen (default) Existing No ex 4x4 2 E Wall ex - - 1 W-16.0 1.19 0.83 Insect Screen (default) Existing No ex 4x1 E Wall ex. -- -- 1 �'� 4.0 1.19 0.83 Insect Screen (default) Existing No ex 4.8x6.7 E Wall ex -- -- 1 32.2 1.19 0.83 Insect Screen (default) Existing No ex 1x3 2 S Wall ex - -1'� 3.0 1.19 0.83 Insect Screen (default) Existing No new 16x6.7 S Wall ex - - 1 107.2 '0.48 0.24 Insect Screen (default) New N/A new 2.7x1 S Wall ex -- - 1 2.7 0.48 0.24 Insect Screen (default) New N/A ex 1.5x1.5 S Wall ex - v 1 2.3 1.19 0.83 Insect Screen (default) Existing No ex 4.8x5 S Wall ex - - 1 24.0 1.19 0.83 Insect Screen (default) Existing No ex 1x1.5 S Wali ex - �,-- 1 1.5 1.19 0.83 Insect Screen (default) Existing No ex 1x1.5 2 S Wall ex -4 > - 1 1.5 1.19 0.83 Insect Screen (default) Existing No ex 1x1.5 3 S Wall ex we-�r� -- 1 1.5 1.19 0.83 Insect Screen (default) Existing No ex 1x1.5 4 S Wall ex`s- - 1 1.5 1.19 0.83 Insect Screen (default) Existing No ex 30.8 S Wall ex -- - 1 11.4 1.19 0.83 Insect Screen (default) Existing No ex 3x1.5 S Wall ex - - 1 4.5 1.19 0.83 Insect Screen (default) Existing. No ex 4.8x6.7 2 W Wall ex �' - - 1 32.2 1.19 0.83 Insect Screen (default) Existing No ex 4` - 1V-- r W Wall ex � - -- 1 4.8 1.19 0.83 Insect Screen (default) Existing No ex z4 -j W Wall exp -- - 1 20.0 1.19 0.83 Insect Screen (default) Existing No ex.`0 W Wa11 ex-* -- -- 1 5.0 1.19 0.83 Insect Screen (default) Existing No ex 43, x WoW II)ex - -- 1' 16.0 1.19 0.83 Insect Screen (default) Existing, No 0p ex 4x9{ DWall ex - -- 1 6.0 1.19 0.83 Insect Screen (default) Existing No C M 9M e o®oma Number: "moi D CA 6' Registration Date/Time: r s - 2013 Residential Compliance Report Version - CF1R-..10172014-651 HERS Provider: Report Generated at 2014=11-04.08:53:35 CERTIFI0OF COMPLIANCE –RESIDENTIAL PERFORMANCE COMPLIANCE METHOD . Project Name: Remodel Residence Calculation Datefrime: 08:52, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xml CIORF-01, Page 5 of 8 DOORS 01 02 03 04 05 01 02 03 04 05 06 Name Side of Building Area (ftZ) U -factor Status Verified Existing: Condition Door NE Wali ex 48.0 0.50 Existing No Door 2 W Waltex 18.1 0.50 Existing• No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 Construction Name Surface Type Framing Total CaviW-value Assembly Layers (n W Nam ® > a®� Distribution Type Number of Heaters Cavity/Frame: no insul. /2x4 Top Chrd Attic Roof. Cons Attic Roofs 2x4 Top Chord of Rooff,� Truss @ 24 in. O.C. - no insulation - Roof Deck: Wood Siding/sheathing/decking 1 Perimeter Existing �w Roofing: Light Roof (Asphalt Shingle) Existing Name Zone Inside Finish: Gypsum Board Default prior To 1978 Ceilings (below attic) 2x4 @ 16 in. O.C. ® R 11 Cavity/Frame: R-9.1 /2x4 . Condition Covered Slab ex Residence ,9A Over Floor Joists: R-1.9 insul. none - 0.8 No y Inside Finish: Gypsum Board R-13 Wall Exterior Walls 2x4 @ 16 in. O.C". R 13 Cavity/Frame: R -13/2x4 _® • Exterior Finish: Wood Siding/sheathing/decking SLAB FLOORS eA� 01 02 0b. 04 05 06 07 08 09 06 (n W Nam ® > a®� Distribution Type Number of Heaters Solar Fraction (%) Status Verified Existing Condition Verified DHW57S < �, Pipe Insulation, All Lines 1 Perimeter Existing Carpeted Existing Name Zone _AArea (ft2) (ft) Edge Insul. R -value Fraction Heated Status Condition Covered Slab ex Residence �" 2452 326 none - 0.8 No Existing. No s� BUILDING ENVELOPE - HERS VERIFICATION AV SYS)TEIW'S 01 02 03 04 Q lity Insulation I st Ila h in (011) Quality Installation of Spray Foam_ Insulation Building Envelope Air Leakage ACH @ 50 Pa 1Jb6pequ" Not Required Not Required - WATER HEATING SYS)TEIW'S 02 03 04 05 06 (n W Nam ® > a®� Distribution Type Number of Heaters Solar Fraction (%) Status Verified Existing Condition DHW57S < �, Pipe Insulation, All Lines 1 Annual Existing No p® p -off Registrati n umber:Z 1711 Registration Date/Time: CA Buildi nergy Efficiency sta�n� - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at 2014-11-04 08:53:35 CERTIFIOOF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD I* Project Name: Remodel. Residence Calculation Date/Time: 08:52, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xml C10RF-01 Page 6 of 8 WATER HEATERS. 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or 7 Efficiency Input Rating Tank Exterior. Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.61 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05' 06 07 Name Pipe Insulation Parallel Piping Comp ct,Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a A& n/a n/a n/a n/a HVAC SYSTEMS' 01 02�" 03 04 01 02 03 04 05 06 07 08 09 EER SEER Zonally Controlled y Heating System Cooling Syftem �� 41ing Cor��oMt 1Z plitAirCond•-Split air conditioning 10.42 12 No No N/A system�� Distribution Fan Floor Area Verified. Existing Name System Type Name Ducted Name SAP Ducted System System Served. Status Condition HVAC1 Other Heating and Heating Yes Cooling`'" Yes' Air Distribution HVAC Fan 2452 Existing - No [ Cooling System Component 1 Compo�nAent 1 System 1 1I I . - — wl�' HVAC - HEATING SYSTEMS 01 �W 02 03 Name w �`0 Type Efficiency Heating Component 1alk.� CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS' 01 02�" 03 04 05 06: 07. C Efficiency Multi=speed M Nar►�� r System Type ® EER SEER Zonally Controlled y Compressor p HERS Verification �� 41ing Cor��oMt 1Z plitAirCond•-Split air conditioning 10.42 12 No No N/A system�� < DOC< '11 y^^ IBJ �m -� C' - z® o #0 Regist tib n Number: -0 Registration Date/Time: CA Bui ir5g Energy EfficienEy S�d r - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at 2014-11-04 08:53:35 CERTIFIOOF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD " Project Name: Remodel Residence Calculation DatelTime: 08:52, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xml CIORF-01 Page 7of8 HVAC - DISTRIBUTION SYSTEMS 01 ` 02 r 03 • 04 01' 02 03 04` 06'06 07 08 09 08 Name Type. Duct Leakage Insulation R -value Supply Duct• Location Return Duct Location Bypass Duct Status Verify Existing Condition HERS Verification Air Distribution, System 1 Ducts located entirely in conditioned space, Existing (not specified) 4'2 Conditioned Zone Conditioned Zone None Existing,, No N/A COOLING VENTILATION 01 ` 02 r 03 • 04 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans - WH Fan 1 61 A � 0.52459 1 v --� a®0 RegisLionNumber: Registration Date/Time: HERS Provider: CA Bc rds - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generatedat 2014-11-04 08:53:35 CERTIFI.OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD • CIORF-01 Project Name: Remodel Residence Calculation Date/Time: 08:52, Tue, Nov 04, 2014 Page 8 of 8 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xml .DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation. Author Signature: Jon d. Scott Jon Scott Company: Signature Date: Scott Design and. Title 24, Inc, 11/4/201.4 - Address: 1/4/201.4Address:. CEA/HERS Certification Identification (If applicable): 77-085 Michigan Drive Ci /State i : Phone:_ �* ry ffalm Desert, CA 92211 - -(7 0) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: .�� 1. I am eligible under Division 3 of the Business and Professions Code -to accept responsibility for�the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate WC-ompliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Comp ance are consistent wit informs ' o id on he applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agencyIf"ot approval with this bui e - io u Responsible Designer Name: 41:i Respo ner Sign Robert A.. Pitchford Company: v Date s ed: /47t 4 Robert A. Pitchford Design and Drafting ( Address: �� License: 77-622 Country Club STE O �® City/State/Zip: 'Phone: ,Pa m Desert-GA_9;2211 (760) 346-2856 0 G)0 0)CD �� M Z O oC z stration Numbered nd�a 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-10172014-651 HERS Provider: Report Generated at 2014-11-04 08:53:35 is 0 F_ _'N L. RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Remodel Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 11/4/2014 Project Address 78-734 Avenida Tujunga La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,452 Addition 0 # of Units 1 INSULATION Construction Type Cavity Area (ftz) Special Features Status Roof Wood Framed Attic R 11 2,452 Existing Wall Wood Framed R 13 5,618 Existing Door Opaque Door - no insulation 66 Existing Slab Unheated Slab -on -Grade - no insulation 2,452 Perim = 326' Existing Demising Wood Framed - no insulation 366 Existing FENESTRATION Orientation Area ftp Total Area: 346FGlaing Percenta e: 14.1%1New/Altered Average U -Factor: U -Fac SHGC Overhang.Sidefins Exterior Shades 0.48 Status Right (N) 37.0 1.190 0.83 none none Bug Screen Existing Front (E) 64.2 1.190 0.83 none none Bug Screen Existing Left (S) 51.2 1.190 0.83 none none Bug Screen Existing Left (S) 107.2 0.480 0.24 none none Bug Screen New Left (S) 2.7 0.480 0.24 none none Bug Screen New Rear (tom 84.0 1.190 0.83 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location .1-16ating Cooling Duct Duct Location R -Value Status HVAC Ducted Ducted Conditioned 4.2 Existing 6 VY A WATER HEATING Qty. Type BUILDING & SAF Gallons Min. Eff Distribution t, �� t tgspT. OR W ni' r, ` DATE 4 4 MANDATORY MEASURES SUMMARY: Residential (Page _1 of 3 MF -1 R' Project Name Date Remodel Residence 11/4/2014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance f specifications whether they are shown elsewhere in the documents or in this summary. Submit allapplicable sections of the MF -1 R Form with plans. .Building Envelope Measures: 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured.to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling orequivalent U -factor. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150.0(c): Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor. *§ 150.0(d): Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor. 150.0 : Air reta rding wrap is tested; labeled and installed accord in to ASTM E1677-95 2000 when specified on the. CF -1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 erm/inch and shall -be, protected from physical damage and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum U -factor of 0.58. 2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)1: Up to, 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is greater, is exempt from the maximum U -factor requirement. . §1,50.0(r) Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project. Fireplaces, Decorative Gas Appliances and Gas Lo Measures: 150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is ,equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited.. S ace Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA. 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of-Section10.2(c). §150.00)1A: Storage gas water heaters rated with an Energy.Factor no greater than the feder I t -standar are wrapped with insulation havingan installed thermal resistance of R-12 or greater. i ((�1 §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heaping em` logG.h&r "{r o t r tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R value is iutdica e. n �'e o o T tank. �`�F" .n I 0 CONSTRUCTION DATE ------- BY EnergyPro 6.3 by EnergySoft User Number: 6712 ID: Page, 4 r L_ MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date 'Remodel Residence 11/4/2014 §150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.0(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0(m)7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150.0(m)10: Flexible ducts cannot have porous inner cores. §150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include all the following components : A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a tirde sWl6gth; tit alio Apar �s '�eT or ro rammed to run onl durin off- eak electric demand eriods. Y Y; , IK I V YLV IVLA m 150.0 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and ,valye.k . 're n o 0 Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for co �pliancewi( s' i ). ance with TABLE 150.0-A or TABLE 150.0-B as applicable. 150.0 k 1 C: The watta a of ermanentl installed luminaires shall be determined ass ecifie 130.0 c . 150.0 k 1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an out u re uenc = §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shalla ra e o cons me no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be re uired to be controlled b vacancysensors. EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 13 of 14 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Remodel Residence 11%4/2014 150.0 k 1 F: Lighting integral to exhaust fans in rooms other than kitchens, shall meet the applicable requirements of §150.0(k). 150:O(k)2: All switching devices and controls shall meet the require imants of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts r for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers: §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of; illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: ; A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other liqhting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. - §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by.vacancy sensors.. ,'L , §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air .leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housin4 and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or, ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2 130.4, 140.7, and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common are R-asipgle building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that buil ingrs rl-ke, i ca aires or t controlled by an occupant sensor. ;I ^ �!! Yit� l a §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area iGW'ij)q1e� b i di u iSQUINT) 20 percent of the floor area, permanently installed lighting in that building shall: AFETy, i. Comply with the applicable DEP in Sections 110.9,.130.0, 130.1, 140.6, J 141.0;,and�� requirements � ii. Lighting installed in corridors and stairwells shall be by that t controlled occupant sensors retlfrc i �ti o�v,7eL% e&h 'froma space by at least 50 percent. The occupant'sensors shall be capable of turning the light fully and gnON in ress and a ress. 7n t ! . QATE EnergyPro 6.3 by Energysoft User Number: 6712 /D: mag 14 P r'• CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel Residence Calculation Date/Time: 08:52, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xml CF1 R -PRF -01 Page 1 of 8 GENERAL INFORMATION. �+--�.b-. fix*«�.s+w..a+.-r�,�, 01 Project Name Remodel Residence 02 Calculation Description Title 24 Analysis ecial Features shown Belo 03 This building incorporates one.or.more Spw 03 Project'Location 78-734 Avenida:Tujunga 04 CA City La.Quinta 05 Standards Version Compliance 2015 06 Zip'code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09, Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 45 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units I 14 TotalCond. Floor Area (FT2) 2452 15 Number of Zones ;1 16 Slab Area (FT2) 2452 17 Number of Stories 1 18• Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) 0 21 Glazing Percentage (%) 14.19/6 COMPLIANCE RESULTS _wcRa►... ,-aS++�w-. .w��, �+--�.b-. fix*«�.s+w..a+.-r�,�, 01 Building Complies wiii� om uter Per0xi,ancer G 02 This building incorporates feat�uris tha`t.require field testirig nd/o4r verification$ a certified HERS rater- un der the supervision of a CEC-approved HERS provider. ecial Features shown Belo 03 This building incorporates one.or.more Spw ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 8.92 8.71 0.21 2.4% Space Cooling 264.51 263.70 0.81 0.3% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 10.00 10.00 0.00 0.0% Photovoltaic Offset — 0.00 0.00 --- TOTAL 283.43 282:41 d .0Y1. '` tTp 0:4°0 RE'CEIVEr-% NOV 05 2014 Re istratiiap NuujW r O fIA2 000000000-0000 CA Building Fie i�"�e ii chi ftrg',Tfi13 Residential Compliance OPMENT Registration Date/Time: 2014-11-04 08:59:12 .Report Version - CF1R-10172014-651 SUILDING & SAFETY DEPT. DROVE® FOR CONSTR CTION [BATF 21L� EI_� ___ Report Generated q f 2M4-11-04 08:53:58 inc. %i CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: Remodel Residence Calculation Daterime: 08:52, Tue, Nov 04, 2014 Page 2 of 8 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xml REQUIRED SPECIAL FEATURES - - The following are features that must be installed as condition for meeting•the modeled energy performance for this computer analysis. • Cooling Ventilation Fan HERS FEATURES The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below, reclure field verification by a certified HERS Rater. Building -level Verifications: -.None - Cooling System Verifications: - None -- HVAC Distribution System Verifications: • Verified low -leakage ducts located entirely in conditioned space Domestic Hot Water System Verifications: -None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components. not regulate 24 Part'6 (such fas domestic appliances{ and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system." .'. j ,. Reference Energy Uset: Energy Design. Rating. Margin Percent Improvement Total Energy (kTDV/f2)' '" �' „ r 327.82 '' ,' 326.80 1.02 0.3% includes calculated Appliances and Miscellaneous Energy Use'(AMEU) BUILDING FEATURE INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling . Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Remodel Residence 2452 1 3 1 1 1 ZONE INFORMATION 01 02 03 04 05 r--_16 _ 07 Zone Floor Area Avg. Ceiling I CITY �� Zone Name Zone Type HVAC System Name (ftZ) Height WatercHeatjng`System 1 ate�,r I e1C s m Residence Conditioned HVAC1 2452 16 i DHW`�Sys'1'"=� �AFEN p Registration Number: 214-A0132062A-000000000-0000 Registration Date/Time: 2014-11-04 08:59:12 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 VED FCR CONSTRUCTION i HEE-RS'SP-r-o_v_ideer_— By CalCER inc. YReport Generate�lc af2934�i 3:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel Residence Calculation Date/Time: 08:52, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xml CFI R -PRF -01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone. Construction Azimuth Orientation 'Gross Area (ft2) Window and Door Area (ft2) Tilt(deg ) Status Verified Existing Condition N Wall ex Residence R-13 Wall 0 315 1755 37 90 Existing No NE Wall ex Residence R-13 Wall 45 Front 200 48 90 Existing No E Wall ex Residence R-13 Wall 90 45 1160 64.2 90 Existing No S Wall ex Residence R-13 Wall 180 135 1755 161.1 90 Existing No W Wall ex Residence R-13 Wall 270• 225 1160 84 90 - Existing No Roof Residence Default prior To 1978 2452 Existing No 'ATTIC 01. 02 03 04 '_ 05 06 09 10 11 Name '? Consist u ction .. ''; R f Rise q Roof ;Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condifion Attic e,. „Attic Roof Con's' f + r' j 3 ` OAQ 0.85. No No Existing No CITY OF LA QUPNTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE �_ By Registration Number: 214-A0132062A-000000000-0000 Registration Date/Time: 2014-11-04 08:59:12 HERS Provider C JS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-6S1 Report Generated at 2014-11-04 08:53:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel Residence. Calculation Date/Time: 08:52, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xml CF1 R -PRF -01 Page 4 of 8 WINDOWS 01 02 03 04 05. 06 07 08 09 10 11 Name Side of Building Width(ft Height ) (ft) Multiplie r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition ex 4x3 N Wall ex -- - 1 12.0. 1.19 0.83 Insect Screen (default) Existing No ex 4x4 N Wall ex -- - 1 16.0 1.19 0.83' Insect Screen (default) Existing No ex 2x3 N. Wall ex -- -- 1 6.0 1.19 0.83 Insect Screen (default) Existing No ex 1x3 N Wall ex -- 1 3.0 1.19 0.83 Insect Screen (default) Existing No ex 2x3 2 E Wall ex -- -- 1 6.0 1.19 0.83 Insect Screen (default) Existing No ex 2x3 3 E Wall ex -- -- 1 6.0 1.19 0.83 Insect Screen (default) Existing No ex 4x4 2 E Wall ex -- - - 1 16.0 1.19 0.83 Insect Screen (default) Existing No ex 4x1 E Wall ex -- -- 1 4.0 1.19 0.83 Insect Screen (default) Existing No ex 4.8x6.7 E Wall ex i - 1 32.2 1.19 0.83 Insect Screen (default) Existing No ex 1x3 2 " S Wall ex -- -- 1 3.0 1.19 .. 0.83 Insect Screen (default) Existing _ No new 16x6.7 SiWall ex ` : "�--w . 1 gz :11072 , 0.48 0.24 Insect Screen (default) New N/A new 2.7x1 " S Wall-exx i. - ' ;1 1 'pr,`2 7 0.48 0.24 Insect Screen (default) New N/A ex 1.5x1.5 - S WaIOU'-f y" , .s 1a ' y 2.3" " �;- 1 19� 0:83 Insect Screen (default). Existing. No. ex 4.8x5+;�"`''S Wall`ex� -_ 1t 24 0"" X1.19 0.83 Insect Screen (default) Existing No ex 1x1.5 -, ,,,4 .S•Wall ex - - 1 1.5 1.19 0.83 Insect Screen (default) Existing No ex 1x1.5 2 S Wall ex ° -- - - 1 1.5 1.19 0.83 Insect Screen (default) Existing No ex 1x1:5 3 S Wall ex -- -- 1 1.5 1.19 .0.83 Insect Screen (default) Existing No ex 1x1.5 4 S Wall ex - -- 1 1.5 1.19 0.83 Insect Screen (default) Existing No ex 3x3.8 S Wall ex - 1 11.4 1.19 0.83 Insect Screen (default) Existing No ex 3x1.5 S Wall ex -- - 1 4.5 1.19 0.83 Insect Screen (default) Existing No ex 4.8x6.7 2 W Wall ex - - - 1 32.2 1.19 0.83 Insect Screen (default) Existing No ex 4.8x1 W Wall ex - 1 4.8 1.19 0.83 Insect Screen (default) Existing No ex 5x4 W Wall ex - - 1 20.0 1.19 0.83 Insect Screen (default) Existing No ex 5x1 W Wall ex - -- 1 5.0 1.19 0.83 In ctc of ul' xist ex 4x4 3 W Wall ex - -- 1 16.0 1.19 0.83 In ec Scrpgnf de�3�uri 's R- �� ex 4x1.5 W Wall ex - -- 1 6.0' 1:19 0.83 Infect Screen (de 4 is66 DEPITq Registration Number: 214-A0132062A-000000000-0000 Registration Date/Time: 2014-11-04 08:59:12 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version.- CF1R-10172014-651 L FOR CONSTRUCTIONE 13Y &Ik er: S inc. Report Generated at 2014-11-04 08: : CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel Residence Calculation Date/Time: 08:52, Tue, Nov 04, 2014 Calculation Description: Title24Analysis Input File Name: Espinola-Pitchford-14.xmi CF1 R -PRF -01 Page 5 of 8 DOORS 01 02 03 04 05 01 02 03 04 05 06 Name Side of Building. Area (ft) U -factor Status Verified Existing Condition Door NE Wall ex 48.0, 0.50 Existing No Door 2 W Wall ex 18.1 0.50 Existing No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 Construction Name Surface Type Framing Total Cavity R -value Assembly Layers t -UH UONSI R(Cefif4 pcisting 5 2x4 Top Chord of Roof Number of Heaters Cavity/ Frame: no insul. /2x4 Top Chrd Attic Roof Cons Attic Roofs Truss @ 24 in. O.C. no insulation - Roof Deck: Wood Siding/sheathing/decking ')A T F Existing No Perimeter • Roofing: Light Roof (Asphalt Shingle) Existing Name • Inside Finish: Gypsum Board Default prior To 1978 Ceilings (below attic) 2x4 @ 16 in. O.C. R11 Cavity/ Frame: R-9.1 /2x4 Status Condition Covered Slab ex Residence • Over Floor Joists: R-1.9 insul. 326 - none - 0.8 No • Inside Finish: Gypsum Board R-13 Wall Exterior Walls '" 2x4'@16"in,OC'*c� rR�13Cavity/ Frame: R -13/2x4 Exterior Finish: Wood Siding/sheathing/decking SLAB FLOORS.'1`' I vUIL UiIV FET DEPT. 01 _ 02 I` 03 04 05 06 07 08 09 t -UH UONSI R(Cefif4 pcisting 5 Distribution Type Number of Heaters Solar Fraction (%) Status Conc�)i{{ion DHW Sys 1 Pipe Insulation, All Lines Verified - Annual ')A T F Existing No Perimeter Carpeted- Existing Name Zone Area (ft) (ft) Edge Insul. R -value Fraction Heated Status Condition Covered Slab ex Residence 2452 326 - none - 0.8 No Existing No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04• Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building. Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required t^ 'V a — . __.N V I S I WATER HEATING SYSTEMS I vUIL UiIV FET DEPT. 01 02 03 04! bUS d 6 • t -UH UONSI R(Cefif4 pcisting Name Distribution Type Number of Heaters Solar Fraction (%) Status Conc�)i{{ion DHW Sys 1 Pipe Insulation, All Lines 1 Annual ')A T F Existing No Registration Number: 214-Ao132062A-000000000-0000 Registration Date/Time: 2014-1.1-04 08:59:12 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-11-04 08:53:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel Residence Calculation Date/Time: 08:52, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xml CF1 R -PRF -01 Page 6 of 8 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.61 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a HVAC SYSTEMS 01 02. 01 02 03 04 05 06 07 08 09 Name Heating System Cooling,System Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning Name S stem,T eme Y Yp ._tDuctsc lfine Y^ r Ducted! Distribution S stem .. Y Fan System Y Floor Area Served. Status Verified Existing Condition HVAC1 Other Heating and Cooling System Heating v Component 1 �<. '.; Yes +� ` _` #_Cooling 1y . a Yes �_�, Air, Distribution Systemrl` HVAC Fan 1 a 2452 Existing No ,�' :. s •Component f � HVAC - HEATING SYSTEMS r. 01 f . 02. 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02. 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10:42 12 No C [ N/A system I Registration Number: 214-A0132062A-000000000-0000 Registration Date/Time: 2014-11-04 08:59:12 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 'NG & SAFE. DEpr, FOR Co �VEJ CTION DATE HER PYarnd BY CaICERT inc. Report Generated at 2014-11- CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel Residence Calculation Daterrime: 08:52, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File Name: Espinola-Pitchford-14.xml CF1 R -PRF -01 Page 7 of 8 HVAC - DISTRIBUTION SYSTEMS ' 01 02- 03 04 O5 06 07 08 09, 08 Name Type Duct Leakage Insulation R -value Supply Duct Location Return Duct Location Bypass Duct Status Verify Existing. Condition HERS . Verification Air Distribution System 1 Ducts located entirely in conditioned space Existing (not specified) 4'2 Conditioned Zone Conditioned Zone None Existing. No N/A11 ,COOLING VENTILATION 01 ` 02 01: 04 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans WH Fan 1 61 0.52459 1 I Registration Number: 214-Ao132062A-000000000-0000 Registration Date/Time: 2014-11=04 08:59:12 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 CITY OF LA QUI:NTA BUILDING & SAFETY FOR PROVED CONSTRUCTIODATE BYHE ro Report Generated at 2014-11-04 08:53:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel Residence Calculation DatefTime: 08:52, Tue, Nov 04, 2014 Calculation Description: Title 24 Analysis Input File: Name: Espinola-Pitchford-14'.xml CF1 R -PRF -01. Page 8 of 8 DOCUMENTATION'AUTHOR'S.DECLARATION STATEMENT 1. 1 certify that this Certificate of ComplianceAocumentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2014-11-04 08:59:12 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 922111 : (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance'conform to the requirements of Title 24; Part 1 and Part 6 of the California.Code of Regulations. 3. The building design features or system design features identified,on this Certificate of_Compliance are.consistent-with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted,to�the enforcement -agency for approvol wdh ikis_ building permit application. Responsible Designer Name: .z.. tA. Responsible Designer Signature: � k Tim Scott s c�r..��+� Company: ', -3 .r m. - .� r., w'Date Signed:.. Scott Design and:Title 24, Inc. 2014=11-04 08:59:12 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: =Palm Desert, CA 9221:1' _ (760) 200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content, of this registered document and in no way. implies Registration information. Registration Number: 214-A0132062A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential. Compliance Registration Date/Time: 2014-11-04 08:59:12 Report Version - CF1R-10172014-651 CITY OF LA UINTA BUILDING (&''SAAF\ETY DEPT. eider i/�}NdYTh�abC/�. the r V STRUCTION DATE . - By I HERS Provider: CaICERTS inc. Report Generated at 2014-11-04 08:53:58