13-1252 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 13-00001252 Property Address: 81550 TIBURON DR APN: 767-522-007- - - Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 8000 •4 44 ���1NIN BUILDING & SAFETY DEPARTMENT r BUILDING PERMIT Owner: ROSEN RESIDENCE 81550 TIBURON DR LA QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/22/13 Contractor: Applicant: Architect or Engineer: LEGACY CONSTRUCTORS INCEFINANCE 78670 HIGHWAY 111, #174 LA QUINTA, CA 92253 (760)880-3445Lic. NO.: 900828`----------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B 7 License No.: 8 028 Date:/O- %Co Tactor: J OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1- I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The ' Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the.project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERA1IT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXMEPT _ (-certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should b e subject to the ' compensation provisions of Section 3700 of the L r Code, sh thwith c p with tl se provisions. r Date / 41icant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if'work is not commenced within 160 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is c rrect. I agree to comply with all city and county ordinances and state laws relating tobuj►d onstruction, an h eb mh rize representatives of this c ntgo enter on the above-mentioned pr rcy f pection p rpo s. Date�4 ure (Applicant ortl: Application Number . . . . . 13-00001252 Permit ELECTRICAL 2013 Additional desc . Permit Fee . . 23.83. Plan Check Fee .00 Issue Date . . . . Valuation" 0 Expiration Date 4/20/14 Qty Unit.Charge Per Extension 1:00 23.8300 ---------------------------- LS ELEC FIXTURES, FIRST 20 ----------------------------------------------- 23.83 Permit MECHANICAL 2013 Additional desc Permit Fee 23.84 Plan Check Fee .00 Issue Date . . . . Valuation• . . . . 0 Expiration Date 4/20/14 Qty Unit Charge Per Extension 1.00 11.9200 EA MECH APPL REP/ALT 11.92 1.00 11.9200 ---------------------------------------------------------------------------= EA MECH VENT FAN 11.92 Permit . . . PLUMBING 2013 Additional desc . Permit Fee 47.68 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/20/14 Qty Unit Charge Per Extension 3.00 11.9200 EA PLBG FIXTURE/TRAP 35.76 1.00 11.9200 ---------------------------------------------------------------------------- EA PLBG WATER INST/ALT/REP 11.92 Permit• . . . REMODEL 2013 Additional desc . Permit Fee . . . 48.62 Plan Check Fee .00 Issue Date Valuation . .. . 0 Expiration Date 4/20/14 Qty Unit Charge Per ._Extension 1.00 48.6200 LS. MISC REMODEL, 1ST 100 SF 48.62 .00 21.4500 EA MISC REMODEL, ADDL 500 SF .00 ------------------------7--------------------------------------------------- Special Notes and Comments ADD BATHROOM IN EXISTING MEDIA ROOM AND PARTIAL WINDOW CHANGE OUT. October 22, 2013 7:52:28 AM jjohnson. ---------------------------------------------------------------------------- Other Fees . . . . . . .. BLDG STDS ADMIN (SB1473) 1.00' LQPERA1IT • Application -Number . . . . . 13-00001252 ---------------------------------------------------------------------------- - Other Fees . . . . . .. . . . PLAN CHECK, ELECTRICAL 23.83 PLAN CHECK, REMODEL 132.99 PLAN CHECK, MECHANICAL 9.54 PLAN CHECK, PLUMBING 47.68 STRONG MOTION (SMI) - RES .80 Fee summary Charged Paid Credited ---------- Due ----------------- Permit Fee Total ---------- 143.97 ---------- .00 ---------- .00 143.97 Plan Check Total .00 .00 .00 .00 Other Fee Total 215.84 .00 .00 215.84 Grand Total 359.81 .00 .00 359.81 de LQPERMIT Bin #f 74 City of La Quinta Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico .._ La. Quinta C— . A 922-53_- _(760)-7_-77.70T2 _� Building_Permit Application and Tracking Sheet Permit.t'f n I2, t l Project Address: � (• 5 ' t V�% �p'�% t Owner's Name: 1*z M'tS. [Zprj�'� A. P. Number: %67 saa • 44 % Address: (S5'Q /SO x-0'1 Legal Description: 1'^4Ta ztovL 54-W4�9D/rq,Q City, ST, Zip: Contractor: Telephone >: �>�>:�;.:<•••;:':::...::;;:::,.:::::.�:�;•::. Address: Project Description: City, ST, Zip:2 Fto t p sA4 o t/ Loow, Telephone: State Lic. # : City Lie. #; Arch., Engr. e§igner: J U& "k NN Address: S �'� (-1'w lit.e . P� lSl City., ST, Zip: lam( r% O C$ ' 7 a"O. .766986 3' k -S I Telephone: %b0 •{qt g • �j? ,.^y.- :�•>�.:��:><:.v�>'><' mi Construction Type: Occupancy: one): New Add'n epair Demo State Lic. # C.i�;Pi:' kLS~ vi':i i :•;:,:.::: <::: ; :# ;>_:......::.;•(circle Name of Contact Person: �� „� `�� Z Sq. FL: #Stories: # Units: Telephone #,of Contact Person: '7 (�j • Q)7c��a Estimated Value of Proj 8 ®Ott APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES �- Plan Sets Plan Check submitted Q Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance eJ Title 24 Calcs. Plans picked up Construction . Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready or correctios/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for correctionsfissue Developer Impact Fee PlInaLing Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees ` CITY- OF LA QUINTA-SUB-CONTRACTOR LIST JOB ADDRESS O. �!%3r�2— PERMIT NUMBER ��j —�� ��i0WNER ,� BUILDER This form shall be posted on the job with the Building InspectionCard at all tiines in a conspicuous place. Only persons ppearing on this list or their employees are authorized to worl on this job. Any -changes to this list must be approved by the Building Division prior to comi-nencernent of work. Failure to comply will result in.a stoppage of work and/or the voidanc( of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response. Trade sification / : Contractor :. ::.:::.::.:: :;:::>::;:>;::::;:;:::>:::; ::.:.:.:::..:» ::;..:.:...::. State:.Contractor s lacense :`' :.Workers Corrjper(sataort Insurance:''.:":' ": City.Buspess License`: :' Company Name Classification License Number Exp. Date Carrier Name Policy Number Exp. Date. 1 License Number Exp. Date (e.g. A, B, C-8) (xxxxxx) (xx/xx/xx) (e.g. State Fund, CalComp) (Format Varies) (xx/xx/xx) 1 (xxxx) (xx/xx/kx) EARTHWORK (C712) - CONCRETE (C-8)'::' MING I -5) - �U 2 / STRUCT.-ST-EEL- (C-51) MASONRY (C>29) PLUMBING (C-36) �,¢�tc c, C/ K �` �� �l �� /. � -S w "TW PLASTER (C-35) WALL (C-9),•..: HVAC. (6 20Y .:::;; .: ELECTRICAL. (C=10) :' .:(c zyu /� (7 0 J . b"31." ROOFING :(C.=39)::..`>' . SHEET.METAL GLAZING (C-:1 ULATION (C72). SEWAGE DISP (6-4 AINTINO (C=33)'-: : f� G C 'MIC TILE (C-54) d U U ��d l CABINETS (C-6) a FENCING (C-13) `'• LANDSCAPING (C=27.) . POOL (C-53) P U _pro I3 -a -13 7 / 07 Z%62_ c-3 OFFI(Gf( BUILDING ENERGY ANALYSIS REPORT PROJECT: Rosen Residence 81-550 Tiburon Drive La Quinta, CA CIN OF LA QUINTA BUILDING & SAFETY DEPT. ' Project Designe : APPROVED FOR CONSTRU TION - DATE Ate— ! 77 Report Prepared by: Joan D. Hacker ' Insu-form, Inc. 77810 Las Montanas Road, Suite_ 201 Palm Desert, Ca 92211 760-345--1352 RECEIVED.'', Job Number: ' OCT 01 2013 CITY OF LA QUINTA Date: COMMUNITY DEVELOPMENT 9/30/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.bnergysoft.com. EnergyPro 5.1 6 ,EnergySoft User Number: 2655 RunCode: 2013-09-30T16:23:16 ID: ' I )no) 440)11 l4woo IAT- F";k! ijj j", I a TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 9 HVAC System Heating and Cooling Loads Summary 12 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE: BY EnergyPro 5.1 by Energysoft Job Number: ID: User Number: 2655 N PERFORMANCE CERTIFICATE: Residential (Part 1 of 5) CF -1 R Project Name Rosen Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family 0 Existing+ Addition/Alteration Date 9/30/2013 Project Address 81-550 Tiburon Drive La Quinta California Energy Climate Zonotal CA Climate Zone 15e Cond. Floor Area T 3,741 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes 0 No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features (see Part 2 of 5) Status Slab Unheated Slab -on -Grade None 3,741 Perim = 152' Existing Wall Wood Framed R-11 1,372 Existing Roof Wood Framed Attic R-19 3,741 Existing FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Front (S) 32.0 0.710 0.73 2.0 none Bug Screen Existing Left (W) 131.4 0.710 0.73 2.0 none Bug Screen Existing Rear (N) 53.4 0.710 0.73 2.0 none Bug Screen Existing Right (E) 46.0 0.710 0.73 2.0 none Bug Screen Removed Right (E) 66.0 0.710 0.73 2.0 none Bug Screen Existing Right (E) 45.0 0.650 0.50 2.0 none Bug Screen New I a"ITY OF LA I pu in nING & SAFETY D - HVAC SYSTEMS i APPROVED Qty. Heating Min. Eff . Cooling Min-Eff r_�n Me . stgTl(5thtus 1 Central Furnace 78% AFUE Split Air Conditioner 10.0 SEER v Setback Existing By HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by Energ Soft User Number: 2655 RunCode: 2013-09-30T16:23:16 ID: Page 3 of 12 PERFORMANCE CERTIFICATE: Residential -(Part 2 of 5) CF-1R Project Name Rosen Residence Building Type. ® Single Family ❑ Addition Alone ❑ Multi Family 17 Existing+ Addition/Alteration Date 9/30/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that,otherwise complies based on the adequacy of the special justification and documentation submitted. r HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. APPROVED r Oe� FR CONSTRUCTION RY DATE i Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-09-30716:23:16 ID: Pae 4 of 12 PERFORMANCE CERTIFICATE: Residential - (Part 3 of 5) CF -1 R Project Name Building Type 10 Single Family ❑ Addition Alone Date Rosen Residence ❑ Multi Family m Existing+ Addition/Alteration 9/30/2013 ANNUAL ENERGYMSE SUMMARY Standard . Proposed, Margin TDV kBtu/ft2 r Space Heating, 3.35 3.48 -0.13 Space Cooling 111.71 108.96 2.75 Fans 20.14. 19.66 0.48 Domestic Hot Water 10.92 10.92 0.00 Pumps 0.00 0.00 0.00 Totals 146.12 143.02 3.10 Percent Better Than Standard: 2.1% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 320 32 Fuel Available at Site: Natural Gas (W) 450 131 Raised Floor Area: 0 (N) 580 53 Slab on Grade Area: 3,741 (E) 350 111 Average Ceiling Height: 9.0 Roof 3,741 - 0 Fenestration Average U -Factor:. 0.70 TOTAL: 328 Average SHGC: 0.70 Fenestration/CFA Ratio: 8.8% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists. the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. 91M9013 Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker O City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Signe6J Date ' The individual with overall design responsibility hereby certifies that the proposed building design represented in this set . of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per'Business & Professions Code) Company 8a' a04 NwY 1/`�tTJG�.�fj( Jul" 6Y-N�� Address Name City/State/Zip , Mt010, Gil-, 6132-0 I Phone 7*0' &Iq'06%5-a' igned icense# Date Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-09-30T16:23:16 ID: Page 5 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Rosen R2SId2nC@ Building Type m Single Family O Addition Alone ❑ Multi Family la Existing+ Addition/Alteration Date g�30/2013 OPAQUE SURFACE DETAILS Surface Tvpe Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status ' 4 Location/Comments Slab 3,741 0.730 None 0 180 Existing 4.4.7-A1 Existing Living Wall 288 0.110 R-11 180 90 Existing 4.3.1-A2 Existing Living Wall 319 0.110 R-11 •270 90 Existing 4.3.1-A2 Existing Living Wall 527 0.110 R-11 0 '90 Existing 4.3.1-A2 Existing Living Wall 239 0.110 R-11 90 90 Existing 4.3.1-A2 Existing Living Roof 3,741 0.049 R-19 180 0 Existing 4.2.1-A4 Existing Living FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 6.0 0.710 Default 0.73 1 Default 180 Existing Double Metal Clear Existing Living 2 Window 6.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 3 Window 4.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 4 Window 4.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 5 1, Window 12.0 0.710 Default 0.73 Default 1801 Existing Double Metal Clear Existing Living 6 Window 54.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 7 Window 33.4 0.710 Default 0.73 Default 270 Existing Double Metal Clear . Existing Living 8 Window 20.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living . 9 Window 4.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 10 Window 20.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 11 Window 53.4 _ 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 12 Window 40.0 0.710 Default 0.73 Default 90 Removed Double Metal Clear Existing Living 13 Window 6.0 0.710 Default 0.73 Default 90 Removed Double Metal Clear Existing Living 14 Window 54.0 • 0.710 Default. 0.731D fault 90 Existing Double Metal Clear Existing Living 15 Window 12.0 0.710 Default. 0.73 Default 90 Existing Doubie'Iv1ewCear, s nq vi 16 Window 4.0 0.650 NFRC . 0.50 NFRC 90 New do, 21 i tpg (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled V Iue�U=DING &SAFETY DEPT. 2 SHGC Type: ' 116-B = Default Table from Standards, NFRC = Labeled V lue EXTERIOR SHADING DETAILS I A.Pppc)N PO ID Exterior Shade Type SHGC . Window H t T Wd Overhan •• ft%F' Len I H t LExt I IRExt 1sten i ht R t Dist Len H t 1 Bug Screen 0.76 6.0 1.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 6.0 1.0 2.0 0.1 2.0 0- _-RY 3 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2. ` 4 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 5 Bug Screen. 0.76 4.0 3.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 6.81 5.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 ' 10 Bug Screen, 0.76 4.0 5.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 6.8 8.0 2.0 0.1 2.01 2.0 12 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 2.0 3.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 1.5 4.0 2.0 0.1 2.0 .2.0 ' Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-09-30716:23:16 ID: Page 6 of 12 y CERTIFICATE OF COMPLIANCE: •(Part 4 • Project Name ;Rosen Residence Building Type 0 Single Family 0 Multi Family 0 Addition Alone 10 Existing+ Addition/Alteration OPAQUE ME10M Joint Appendix 4 Location/Comments FENESTRATION 1111110M. �s� Location/Comments m •• I. I® I I ®�� ••i Existing Living 1 ... EXTERIOR SHADING DETAILS ExteriorSh . deType CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Rosen Residence Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family © Existing+ Addition/Alteration Date 9/30/2013 BUILDING ZONE INFORMATION System Name Zone Name New Floor Area ft Existing Altered Removed Volume Year Built Living Zone Existing Living 3,741 33,669 1978 Totals 1 0 3,741 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Living Zone 1 Central Furnace 78% AFUE Split Air Conditioner 10.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Cooling Duct Duct Location R -Value Ducts Tested? Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing 010INTA I— BUILLP11MUG' WATER HEATING SYSTEMS I ,fit, System Name Qty. Type DistributionBtuh Rated Input Tank , (Sap. ,1I FOR C QNSTR nergy tandby Factor Loss or or RE Pilotgav JQ4 Tank Insul. R Value S Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50"' 0- n/a n MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o cu Q S stem Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-09-30T16:23:16 ID: Pa e 8 of 12 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Rosen Residence Date 9/30/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the CertifiCate of'Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. §150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention,. pumpisolation valve, and recirculation loop connection requirements of113 c §115: Continuously burning pilot lights are prohibited for natural gas: fan type central f WrnaceX;oseold-c©o ' g li-y� 'j'Q (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 BtJ/f� a tt a}i adj �n spa heaters. ;I 1! 1% (` EfY D P §150(h): Heatingand/or coolingloads are calculated in accordance with ASHRAE, SMACNA or AC,QA, 150 i : Heatingsystems are equipped with thermostats that meet the setback requirements ofS,e t�'or §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the f deral rViii 'r4thNt a d are a ernally wrapp with insulation havingan installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water' heatin�q system, or otheOdirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation Fi-value-is-hftare-d on the ex error of the tank. -� §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1506)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(0)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-09-30716:23:16 ID: Page 9 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Rosen Residence 9/30/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150 k 2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified 13 §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and sh II Fiaq 4 4n,6uU1Jfre&A7cQUMaFA 20 kHz. ( r„ its i r` 0 CACT711-V §150(k)5: Permanently installed night lights and night lights integral to a permanently installe J IufhM'' aus an s a I c —a—in only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contai , a ��je° f e r I e - voltage lamp holder; OR shall be rated to consume no more than five watts of power as dete(mined �°yv 13Q(�ai r�t�r t�n a medium screw -base socket. I r �+ 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. DATE BY §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting.in.kiic EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-09-30T16:23:16 ID: Page 10 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Rosen Residence 9/30/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)l1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual- on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not 'be hi h efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable re uiremerat CITY OF BUILDING & SAFETY DEPT. ,APPROVED FOR CONSTRUCTION I DATE BY EnergyPro 5.1 by EnergySoff User Number: 2655 RunCode: 2013-09-30716:23:16 ID: Page 11 of 12 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Rosen Residence 9/30/2013 System Name Floor Area Living Zone 3,741 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 2,479 0 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM - Sensible Output perSystem 70,000 44,470 3,443 1,164 40,034 Total Output Btuh 70,000 0 Output Btuh/s ft 18.7 3,771 2,844 Cooling System 0 0 Output perSystem' 58,000 0 0 0 0 Total Output Btuh 58,000 0 3,443 0 Total Output Tons 4.8 1 3,771 2,844 Total Output Btuh/s ft 15.5 Total Output �s ft/Ton 774.0 52,011 1 45,723 Air System CFM perSystem 1,300 HVAC EQUIPMENT SELECTION Airflow cfm 1,300 Existing HVAC 41,094 11,103 70,000 Airflow cfm/s ft 0.35 Airflow cfm/Ton 269.0 i Ir AF E:Y DEM Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) �# 41,09 Q3 70,000 I O V ED T Outside Air cfm/s ft . 0.00 Note: values above given at ARI conditions TIME OF SYSTEM PEAK ug Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating P ak) i DATE BY 26 OF 69 OF 69 OF 104 OF (-- Outside Air 0 cfm Supply Fan Heating Coil 102 OF 1,300 cfm .. ROOMlk'14 69 OF 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 112/78°F 80/66°F 80/66°F 59/58°F I Outside Air 0 cfm Supply Fan Cooling Coil 61 159 OF 1,300 cfm 50.6% ROOM 80 / 66 of 78 ! 65 OF --�� EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-09-30716:23:16 ID: Page 12 of 12