Loading...
09-0896 (RER)P.O. BOX 1504• 78-495 CALLE TAMPICO LA QUINTA; CALIFORNIA 92253 Application Number: 59-4000089.6_,' Property Address: 81620 TIBURON DR APN: 767-531-005- - - Application description: REMODEL - RESIDENTIAL. Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 8000 Applic nt: Architect or Engineer: ----------------- LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT. I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with - Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B LicenseNo.: 863749 Date: Contractor: /f/ 1 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the followingreason(Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a. signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( I I, as owner of the property, or my employees with wages as their sole'compensation, will do the work, and the structure is not intended or offered for sale ISec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the - improvements are not intended or offeredforsale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ j I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves, thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 I I am exempt under Sec. , BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY . I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.I. Lender's Name: _ Lender's Address: LQPERMIT Owner: ANZURES 816,20 TIBURON LA QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/21/09 Contractor: GRAYSTONE CONSTRCTION COM LA405 HIGHWAY 111, QUINTA, CA 92253 SEP (760) 564-6934 ., Lic. No.: 863749 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 -of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: -- Carrier STATE FUND Policy Number 1828934 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I Vall forthwith c--la hose provisions. Date: W1110. Applicants WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 19100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN, SECTION 3706 OF THE LABOR.CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under.or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives ofthis',cryo/unty/to enter upon the above-mentioned property ffor�i0nslpection purposes. Date: % �` C7 Signature (Applicant or Agent): L- . Application Number . . . . . 09-00000896 ------ Structure Information GARAGE REMODEL (2+1 CAR REVISION) [ENG] ----- Other'struct info . . . . . CODE EDITION 2007CBC --------------=---------------------.---------------------------------------- _ _Permit . . . BUILDING PERMIT INV.FEE Additional desc . Permit Fee 198.00 Plan Check Fee.. 64.35 Issue Date. Valuation . . . . 8000 Expiration Date 3/20/10 Qty Unit Charge Per Extension BASE FEE 90.00 6.00 18.0000'THOU BLDG 2,001-25,000 108.00 -------------------------------------------=-------=------------------------ Special Notes and Comments GARAGE REMODEL 7"2+1 VEHICLE ENTRY REVISION [ENGINEERED] 2007 CALIFORNIA BUILDING CODE. ***INVESTIGATION FEE ASSESSED PER 2007 CALIFORNIA BUILDING CODE APPENDIX CHAPTER 1 §108.4 FOR WORK COMMENCING BEFORE PERMIT ISSUANCE*** September 21, 2009 3:24:39 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 STRONG MOTION (SMI) -RES .80 ' Fee summary Charged Paid Credited, Due Permit Fee Total 198.00 .00 .00 198.00 Plan Check Total 64.35 .00 00 64.35 Other Fee Total 1.80 .00 .00 1.80 Grand Total 264.15 .00 .00 264.15 LQPERMIT 3I V •C °► alb -JVs �'�. C� � • City of La Quinta Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Q` 7/ Project Address: 1 6z o --1 (3 (/,°Zo nj ='Owner's Name: A. P. Number: Address: b Z0 -7—,, Ott 0 N Ate. Legal Description: -City, ST, Zip: Contractor: �� S'TU r -e C o n S T G w•.,;: :+•� Telephone + "" s'r` f ?cu y� ...� o'r`s >R5?e: Address: .-7 c Project Description: City, ST, Zip: !1— cf Z Z 3 �,. N.. inti • 'b+� \. Telephone: � � `�'`��^'• s-;.,: s �,p,• <�� {�:.;:.._ :�:•. .: �.!d:'<+..::<:. J.: +ikx +:):.�. •: n��.- z - 1 CvL GAM ,L-- D(ia �S A T-,, C_ LO/✓Y.y M i nS �/i c State Lic. # : �j 3 % C(y City Lic. #: Arch., Engr., Designer: u.v�CC Address: City., ST, Zip: Telephone:, State Lic. #: '.4` J+. �..::.. y v :>ti5..>> , f>ts:;::r•;.:^..�+ Construction Type: Occupancy: a air Demo tYPecircle one). New Add'n er Name of Contact Person: ZIC- se -.H nic'It E-� Sq. FL: # Stories: #Units: Telephone # of Contact Person: 76o, Z3 S, D Estimated Value of Project: 000 -r— APPLICANT: DO NOT WRITE. BELOW THIS LINE # Submittal Plan Sets Req'd Recd TRACKING PERMIT FEES . Plan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections 9 Plan Check Deposit t— Truss Cafes. Called Contact Person '� S Plan Check Balance. Title 24 Cafes. Plans picked up Construction .� Flood plain plan Plans resubmitted _ I Mechanical Grading plan 21' Review, ready for correcti e� Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up. S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review,.ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. .r Pub. Wks. Appr Date of permit issue i" ,.— School Fees Total Permit Fees 3I V •C °► alb -JVs �'�. C� � • AUG/07/2009/F R I 04---V PM The. Monarch Croup i~ All No. I bU !/b 5 t 1 I, r. uu i i uu i PGAVR=, I 'FAIRWAYS ASSOCIATION August 6, 2009 David Anzures, Sr.. i 11533 Bradley Ave. i SanTenmando, CA 91340 Re: Architectural Application Approval for 81-620 Tiburon Dr. )[:a Qainta, CA.92253 � Dear Mr. Anzures: I The Architectural Committee reviewed your plans for converting your double garage door into a single garage door. , t pleased, to inform you the Architectural Committee has approved your application with the following condition: • Receipt of $1,000 Construction Deposit beforevem mencement of the project Please forward `that check payable to PGA WEST Fairways Association to the address below within ten days. E64osed is Exhibit C, Compliance Review Requsest foim- Please complete that form after the construction project is completed, and mail or fax to the address below. 3 If you have any, questions, please contact Joe Gibbs, Operations Manager at 760-776-51.00 East. 345. i Sincerely,. I For the Architectural Committee PGA WEST Fairways Association OWD ala, PCAM'AUG 24 2009 Manager g �Y _ Encl. Compliance Review Request Form cc: Lot File ! Mark Schneider, Greystone Construction Co., via fax 760-775-8833 ! Post Office Box 1690 - La Quinnta, Califomia 92247. • Phone' (760) 776-5100 - Fax (760) 776-5111 i 41-865 BOARDWALK, SUITE 208 PALM DESERT, CA 92211 ` P: (760) 836-1000 F. (760) 836-0856 WWW.G02LEI.COM LITECKY ENGINEERING INC. September 15, 2009 ' GC - Ray Rooker Architect 49852 Rancho San Francisquito QTY OF LA QUANTA. La Quinta, CA. 92253. BUILDING & SAFETY DEPT.. APPROVED Re.: The-Anzures Residence FOR CONSTRU ON Garage Remodel 81620 Tiburon Avenue DA 8 La Quinta, Ca. 92253 Job No. 0906;1 _ 01W&K W1Uz j Dear Ray In regards to the`above mentioned project; and per our conversation on August. l7; 2009 and September 15, 2009, we submit the following: Please see the attached paitiaopening l framing and foundation plan showing the.revised at the' garage door (including the added shear panel at the garage'to account for the lateral load along this line. of the structure). Please note that existing Hardy Frame Panels along this line are' to be removed and replaced with the plywood shear panel, as shown on the partial framing.and foundation plan. Also, please tefer.to details VSD -1 through 5/SD-1 for the required connections as well as the attached calculations. Please note that because the `existing footing in the garage is 12" wide x.18" deep, the pad -verification at the beam #1 supports is no longer required due to.the increased point load capacity of the existing footing:. Verify the. above information, with the building department prior to construction. If you have any questions, please do not hesitate to contact our office. OQROFESS�� . F C 71171 m * EXP. 06-30-11 Anthony Litecky, P.E. 4P CIVIL o Attachments (13) CCAUFe Copy: File . 1- PLYWOOD SHT'G 4 3 2 1 2- TRUSS BY MFR. 3- 8d's ® 6" O.C. 4- 2X BLK'G 6 5- DB.L TOP PLATE OR BM & SIMPSON A35,SEE TABLE. • FOR SPACING • 7- SHEAR PANEL TYPE 12 TYP. (U.N.O. ON PLANS) 12 8- SEE PLAN FOR TYPE AND LOCATION 9- ALT.' LOCATIONS OF SHEAR PANEL INSIDE SEE PLAN 10- 2x FREEZE BLOCK 11 -EDGE NAILING 12-SIMPSON H1 RFOUIRFD 8:. �js�, A35 A 48' B 40' C 32'' D 24' E 16' f 8' �js�, v 1.4x4 POST, U.N.O. SEE PLAN. _2: SEE TABLE. LL D, 3. EMBEDMENT IS FROM TOP OF SLAB`AT 2 MONO -POUR FOUNDATION SYSTEM. 4. OPTIONAL COLD JOINT AT 2 -POUR SYSTEMS. 2 4 5. EMBEDMENT IS FROM COLD JOINT AT 2 -POUR SYSTEM. NOTES: (3 )mayA USE SIMPSON "SET -XP" EPDXY (DO NOT SUBSTITUTE) . APPROVALS :ICC ESR -2508 5 ° REFER TO ICC AND MANUFACTURER's a SPECS. FOR INSTALLATION PROCEDURES. 1 3/4" a SPECIAL INSPECTION IS REQUIRED, DURING MIN : d. ° ALL INSTALLATIONS. MIN. CONCRETE STRENGTH f c= 2500 psi ADEQUATE SIZE WASHER REQUIRED WHEN ANCHOR BOLT SIZE IS SMALLER THAN MISSING REPLACE W/ RODU EMBEDMENT HOLDOWN STRAP* HDU5 SO apo AND HD2A, HD5A .HOLE IN HOLDOWN. CONTRACTOR SHALL SPECIFY OVERALL LENGTH OF ANCHOR. 1- 5/8" WEDGE' ANCHOR USE (1) WEDGE ANCHOR TO REPLACE EACH MISSING INT. WALL ANCHOR BOLT AND USE (2) WEDGE ANCHORS TO REPLACE EACH MISSING A.B. ® EXTERIOR SHEAR WALL & SHEAR WALL BWTN. HOUSE AND GARAGE. 2- 2 1/2" MIN. ® EDGE OF FTG. CONDITION & CENTERED ® INTERIOR WALL CONDITION. 3- 4 1/2" MIN. ® WEDGE ANCHORS & 5" .0 EPDXY. NOTES: WEDGEANCHORS CAN BE SIMP. WEDGE ALL (ICC ESR -1396) OR ITW/RAMSET RED HEAD WEDGE ANCHOR NO SPECIAL INSPECTION IS REQUIRED FOR WEDGE ANCHORS. FOLLOW MFR. RECOMMENDATION FOR INSTALLATION. MIN. SPACING BTWN. ANCHORS:TO BE 9" IF SPACING IS LESS THAN.9", USE THREADED RODS.EMBEDDED 5" INTO CONCRETE W/ SIMPSON "SET -XP" EPDXY (ICC ESR -2508) SPECIAL INSPECTION IS REQ'D FOR THIS SYSTEM. O DESIGN CRITERIA (GENERAL DESIGN CRITERIA SEISMIC LOADING LOCATION: LA QUINTA, CA (ZIPCODE: 92253) Ss =1.515 Si =0.600 SDs =1.010. Sm = 0.600 SEISMIC DESIGN CATEGORY D (IBC. SECTION 1613.5:6) SITE CLASS D (ASSUMED) (IBC SECTION 1613.5.2) OCCUPANCY CATEGORY II (IBC TABLE 1604.5) SEISMIC IMPORTANCE FACTOR I=1:00 (ASCE 7-05, TABLE 11.5-1) RESPONSE MODIFICATION COEFFICIENT R = 6.5 '(ASCE 7-05, TABLE 12.2-1) AT HARDYFRAME PANEL R = 6.5 (BF CATALOG 6-08) AT CANTILEVER STEEL COL UMNR 1.5. (ASCE 7-05, TABLE 12.2-1) REDUNDANCY FACTOR p =1.30 i (ASCE 7-05, SECT. 12.3.4:2) BASE SHEAR V.= p x [SmI/(L4 x R)] x W (ASCE 7-05; EQU. 12.8-1 & 12.8-2) BASE SHEAR V =-1.30'x [1.010 x 1.0/(1.4 x 6.5)] = 0.145W . DESIGN CRITERIA -WIND LOADING ASSUMED MOST CONSERVATIVE ROOF ANGLE = 20° ` ps30 =17.8 PSF (ASCE 7-05, FIGURE 6-2) WIND EXPOSURE CATEGORY C - (ASCE 7-05, SECT. 6.5.6.3) WIND IMPORTANCE FACTOR I =1.00 (ASCE 7-05, TABLE 6-1) . BASIC. WIND SPEED 90 MPH (ASCE 7-05, FIGURE 6-1) TOPOGRAPHIC FACTOR Kz =1.00 (ASCE 7705, SECT. 6.5.7.2) WIND FACTOR ps = 7L x KzT. x I x ps30 (ASCE 7-05, EQU. 6-1) MAXWUM HEIGHT 15 ft (7, = 1.21) WIND FACTOR ps = 21.54`psf MA3UMUM HEIGHT 20 ft O; = 1.29) WIND FACTOR ps = 22.97 psf MAXPAUM HEIGHT 25 ft (7C = 1.35) WIND FACTOR ps.= 24.03 psf . MAXGMUM HEIGHT 30 ft (7L = 1.40) WIND FACTOR ps = 24.92 psf COMPANY PROJECT Ultecky Engineering, Inc. jj� 4186 5 BoardwalK Sure 208 1Noo WVrks . Pagn Desert, CA 9221, .. .. SORWAUrm WOOD DFUrN ' . Aug. 19,2D09 1*12 Beam #1 - Drop BM at Garage.wwb Design Check Calculation Sheet Sizer 2004a LOADS ( lbs, psf, or pIt 1 Load Type Distribution Magnitude Location (ftj 2at- Shear 2864 Total Start End Start End tern Loadl Dead Full Area 20.00(14.50)* 2 No Load2 Live Full Area 20.00(14.50)* No Load3 sm..: �...«.. _.. Dead Full Area 15.00 (1.00)* L/360 No MAXIMUM REACTIONS (Ibs) and. BEARING LENGTHS (in) : LOA 19-9" I 3160 Dead 3160 Design Live 2864 Shear 2864 Total 6024 190. 6024 Bearing:' fb = 1857 Fb' = 2 fb/Fb' = 0.79 2 LC number Length .' 2.35 2.35 Glulam-Unbal., West Species, 24F-1.TE WS, 5-1/8x15" �iI 5"7/�iNO�� Self Weight of 14.99 plf automatically inducted in loads; m Lateral support top= full, botto= at supports; Load combinations: ICC -IBC; ng Analysis vs. Allowable Striess (psi) and Deflection lin) usinos 2001 Criterion Anal sis.Value Design Value Analysis/Design Shear fy = '103 Fv' = 190. fv/Fv' = 0.54 Bending(+) fb = 1857 Fb' = 2361 fb/Fb' = 0.79 Dead Defl'n 0.45- L/530 Live Defl'n 0:41 = 'L/584 0.66 = L/360 0.62 Total Deflln 0.85 L/278 0.99 = L/240 .0.86 ADDITIONAL DATA: FACTORS: F CD CM Ct CL CV Cfu Cr Cfrt Notes Cn LCA Fb'.+ 2400 1.00' 1.00 '1.00 .1.000' 0.984 1.00' 1.00 1.00 1.00 - 2 £v' 190 1:00' 1.00 1.00 - - - 1.00 1.00 1.00 2 Fcp' 500 - 1.00 1.00. -. - - 1.00 - - E' 1.7 million 1.00 1.00 - - - - 1.00 - 2 Custom duration factor for Wind load = 1.33 Bending(+):• LC@ 2 = D+L, M = 29742 lbs -ft 11+L,Shea. : LCN 2 = +L, V = 6024, V design = 5261 Lbs Deflection: LC#4 2 = D+L EI= 2450eO6 lb-in2 Total Deflection = 1.00(Dead Load Deflection) +.Live Load Deflection. .(D=dead L --live S=snow' W=wind I=impact C=construction CLd=concentrated). (All LC's are listed in.the'Analysis output) DESIGN NOTES: " 1. Please verify that the default deflection limits are appropriate for your application. 2. Glulam design values are for materials conforming to AITC 117-2001 and manufactured in accordance with ANSUAITC A190.1-1992 3. GLULAM: bond = actual breadth. x actual depth. 4. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3. 5. GLULAK bearing length based on smaller of Fcp(tension), Fcp(cmWn). LATERAL ANALYSIS SECTION # 1 LONGITUDINAL PLATE HEIGHT = 9.00 FT ROOF AVERAGE HEIGHT =13.00 FT WIND FORCE (90 MPH) = 21.54 PSF WIND LOAD = 21.54 psf x (13.00 ft-9.00ft/2) 184 PLF SEISMIC LOAD= 0.145 x ((20.00 x 45.0.0)+(15.00 x 2 x 4.50}10.00 x l x 4.50) SEISMIC LOAD= 157 PLF