Loading...
BPLB2014-104878-495 CALLE TAniIPICO LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BPLB2014-1048 . Property Address: 78705 AVENIDA TORRES APN: 770172005 Application Description: PLUMBING FOR SOLAR POOL ONLY Property Zoning: Application Valuation: $16,000.00 Applicant: SUNUP SOLAR SYSTEMS, INC 81692 HIDDEN LINKS DR LA QUINTA, CA 92253 DQ �. DEC 1 120114 CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C46 License No.: 992607 Date: Iti'((� (�/ c tractor: Ma., J4� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044,. Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however; the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she. did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I I I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/11/2014 Owner: SWARTHOUT, PATRICK & LEAH 78705 AVENIDA TORRES LA QUINTA, CA 92253 Contractor: SUNUP•SOLAR SYSTEMS INC 81692 HIDDEN LINKS DRIVE LA QUINTA, CA 92253 (760)564-6916 Llc. No.: 992607 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjuryone of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:_ Policy Number. _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: ti— I I— � y APpl�gf L'A Ua SJtL, Sylt�rlsc WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS, ($100,000). IN ADDITION TO THE COST. OF COMPENSATION, DAMAGES AS PROVIDED FOI IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1-. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. Date: Signature (Applicant or Agent). 7, AMOUNT,�PAID`DAT�E 5 ETL"."4.'F„ �'k •� '-<"�}£E+g�S�£��i'1 >•¢ `ACCOUNT"' TY-`aF .»RESGRIRTION� " BSAS SB1473 FEE 101-0000-20306 0 gi �' r a tTM PAID BY:, .y. � � METHOD .,, P c s. Vii¢. `RECEIP,T # ,1.02 CK # CL4TO BY O,�....". v.W � .>:i. ,zW.3.a°� ;c��`irs€3t`",.� .::, -� iP�� SUNUP.SOLAR SYSTEMS, INC ',,'CHECK 1064 MFA`. - Total,PaidforBUILDINGSTANDARDSADMINISTRATION BSk'. $1.00. ,. .$1.00 p « DESCRIPTION ��� arACEOUNT > r� >, �k � (AMOUNT 4��'"" PAID. " PAIU"DATEw : rn. --.-"..N.Tx_.:�ti�.,�.s:r,^Vz="x: PERMIT ISSUANCE... 101-0000-42404. 0 ",$91.85 $91:85 ' 12/Tl/14' «,. ri �.i 'PAID,:BY` ,, M �METHODi� a- ;: RECEIPT# CHECK#,:.CLTDB,Y :M.. .> : ,ss-� g�xar a� SUNUP SOLAR'SYSTEMS, INC CHECK R3181. 1064 MFA_ Total Paid.f6ePERMIT•ISSUANCE:''., ... $9185:; :: $91.85 .:`r.i.'ma4'fi q ., R., z ,� .:.::-F 3 fr DESCRIPTIOPI� ` ,� z:" <�ACCOUNT QT=Ys�AMOIJNT i41D 'PAID?DATE°' YS��.Y?36'.v{ �ai?Wz4:t'.k;3T.�iv.x .�e,'+' 4.e'3h.':,F-'._�at23+s:G'�Y; ry q X_ 10 WATERSYSTEM INST/ALT/REP,' 101-0000 42401 0 .$12 09' $12:09 .i' 12/11/14 w, �t.?3k�R,'°.sv.'�t' ` m,<a BY�s; :: ¢?,.t?:L r;2t�5 METHODa� vn�RECEIPT�# �..�M..f.z"r�%..,3 xY.°.k'R-'z3"?x.. 4,CIiECK # F� ;Ei;.,.L•r eZ c�.n*'. .PAID v`� �{+vF.> �&. rs`��..> . w`.+•„' +�.! `S£ �3��N-S.9-4@�,Rd�n"3;:YE3dv`CI i DIBY'' y��CLTD'BY' SUNUP SOLAR SYSTEMS, INCA _ � CHECK R3181 ; ;1064. • MFA , - - �F "5.y,.'''�`�`c' ; ��' §-%;.j.^,f�$ ACCOUNT ems', TY �7Y ��^•�•+�'`.. •. ^�'.?`a AMOUNT, fig' Y'' nyFa^3%z �b(y PAID '-�' vC.y».fl;aft 3�+n-t �vsa PAID.DATE.�> aDESCRIPTION �. � • .. .-� . AMM.' IV. lallu ,,w� a x WATER SYSTEM INST/ALT/REP-PC 101-0000-42600 0.., $12.09, f .$12:09 12/11/14 r<; c-`•Ti R PLAID BYE -.` s ' aS:;i,.'„o- 4i:.i�..`Y-.g..... ,'�°�' Ei �`.`i�*;fi°ya,.s�p._:'a .,. ".. METIOD M',r�RECEIPT#�> . A . C C(#�CLT,D48Y SUNUP SOLAR SYSTEMS, INC . - 'CHECK .; R3181 ... '1064 . _MFA : Total Paid for PLUMBING FEES .: $24 18, $24:18 • • Description: PLUMBING FOR SOLAR POOL ONLY Type: PLUMBING Subtype: Status: SUBMITTED Applied: 12/11/2014 MFA Approved: . Parcel No: 770172005 Site Address: 78705 AVENIDA TORRES LA QUINTA,CA 92253 Subdivision: DESERT CLUB TR UNITS Block: Lot: 162 Issued: y Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $16,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: SOLAR POOL WATER HEATING SYSTEM - 3605F COLLECTOR AND PIPING TO EXISTING POOL PUMP TO BE REPLACED. THIS PERMIT DOES NOT INCLUDE ADDITIONAL OR ALTERATION TO EXISTING POOL PUMP. 2013 CALIFORNIA BUILDING CODES. CONDITIONS FINANCIAL,, INFORMATION Printed: Thursday, December 11, 2014 3:26:58 PM 1 of 2 PARENT PROJECTS BOND INFORMATION . ���� 'ATTACHMENTS Printed; Thursdav, December 11, 2014 3:26:58 PM 2 of 2 OYOTIM& .,� r. Y weF,-., �° .'C.'Y...." �' YMrM Y� Y �3d %i Z .✓�.'r �rc'"'..e�,ty�a , ��'..:A "77777, CLTD, DESCRIPTION T ACCOUNT "" ._, s TY 4` r AMOUNT' PAID PAIDDATE. RECEIPT# CHECK #— .METHOD"" .-'' 'PAID BY z c a vBY,. _. BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 12/11/14 R3181 1064 CHECK SUNUP SOLAR MFA' SYSTEMS, INC Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: PERMIT ISSUANCE 101-0000-42404 0 S $91.85 $91.85 12/11/14 R3181 1064 CHECK SUNUP SOLAR MFA SYSTEMS, INC Total Paid for PERMIT ISSUANCE: $91.85 $91.85 WATER SYSTEM 101-0000-42401 0 $12.09 $12.09 12/11/14 R3181 1064 CHECK SUNUP SOLAR MFA INST/ALT/REP SYSTEMS, INC WATER SYSTEM 101-0000-42600 0 $12.09 $12.09 12/11/14 R3181 1064 CHECK SUNUP SOLAR MFA INST/ALT/REP PC — SYSTEMS, INC Total Paid forPLUMBING FEES:, $24.18 $24.18 TOTALS:• PARENT PROJECTS BOND INFORMATION . ���� 'ATTACHMENTS Printed; Thursdav, December 11, 2014 3:26:58 PM 2 of 2 OYOTIM& IJ CITy,,o WIN -8 BUILD , ING AETY, DEF 36 !`I). tv Ml `/1 i''Solar � Industries Uo: L ,in O Patented Sun Tracking Tube and Curved Web Design Maximizes heat gain throughout the d, G Multi -Plate Construction Allows for wind relief during extreme weather conditions as well as for thermal expansion and contraction. o Stainless Steel Mounting Hardw Greater strength and rust free with fe%A mounting points for easy installation. o All Welded Construction For maximum strength and durability. a Direct Flow Design • Compatible with today's high flow, high efficiency pool filtration systems - available in low profile 1-1/2" manifold for residential pools or a 2" heavy duty commercial design. DIMENSIONS Model 1500 Series Model 2000 Series Collector Cross Section showing heat trap design for better all day performance, even on windy days. Ho@&L ME& FLUID FLOW RATES Model 1500 Series Model 2000 Series Model Number 10001-5 10001-2 10001-1 10204-12 10204-10 10204-8 Model Number 10001-5 10001-2 10001-1 10204.12 10204-10 10204-8 S Nominal Size ft. 402 410 48 4x12 400 48 Maximum -GPM 10.0 10.0 10.00 10.0 10.0 10.0 Overall Collector Length -in 144.0 120.0 96.0 144.0 120.0 96.0 Minimum -GPM 3.0 2.5 2.5 3.0 2.5 2.5 , Collector Width -in 47.0 47.0 47.0 47.0 47.0 47.0 Recommended -GPM 5.0 4.0 3.25 5.0 4.0 3.25 j Manifold Length -in 50.5 50.5 50.5 50.5 50.5 50.5 Max. Collector with Single Manifold O.D.-in 1.9 1.9 1.9 2.4 2.4 2.4 Feed @ Recommended Manifold I.D.-in 1.5 1.5 1.5 2.0 2.0 2.0 Flow Rate 10 12 12 12 14 14 I Gross Collector Area-ft2 47.3 39.3 31.4 47.3 39.3 31.4 Net Collector Area-ft2 47.3 39.3 31.4 47.3 39.3 31.4 fff! PRESSURES WEIGHTS Pressure Drop: 0.14 ft head (0.06PSI) pressure loss @ recommended flow Dry -lbs 21.3 17.1 14.3 22.3 18.1 15.3 rate 0.09 ft head (0.04PSI) pressure loss @ minimum flow rate Wet -lbs 48.0 41.6 35.1 54.0 47.6 41.1 Max. Fluid Pressure: Greater than 85 PSI @ 80°F Wet Ibs-ft2 1.0 1.0 1.1 1.1 1.2 1.3 Recommended Max Fluid Capacity -gal 3.2 2.9 2.5 3.8 3.5 3.1 Operating Pressure: 35 PSI @ 140°F s I Solar'Industries Pool System Schematic THERMAL PERFORMANCE RATINGS Florida Solar Energy Center Certification Thermal Performance Equation' -n = 85.8 - 3.42 4x12 - 47,700 (BTU's per std day) Incident Angle Modifier-Kqr =1.0 - 0.03 410 - 39,800 (BTU's per std day) (Rated in accordance with ASHRAE standard 96-80) 48 - 31,800 (BTU's per std day) 8 Collectors N N 10 Collectors 12 Collectors. o 8 Collectors N 10 Collectors in 0 0 12 Collectors N 0 2 14 Collectors FPressure Multiple Solar Drop in H WFeet Industries with Collectors MMMENE, EMMMEN MEMMME MMMENE EMMMEN MEMMME EEEMMM_ 25 30 40 50 60 70 - FLOW RATE (GPM) GUIDE SPECIFICATIONS Contractor to supply and install collectors, nominal size (412, 410, 48) with overall frontal area of (47.3, 39.3, 31.4) square feet each. Collectors shall be fabricated from a propylene copolymer with stabilizer combination providing long tens resistance to heat and light. The weight of collector when filled with water shall be no more than 1.3 pounds per square foot of frontal area. The collectors shall be capable of withstanding an internal static pressure of 85 psi at operating tempera- ture and shall be resistant to corrosion, freezing, and internal scale accumulation. Collectors shall be capable of thermal performances of at least 85% efficiency when inlet fluid temperature equals ambient temperature and be capable of collect- ing solar energy when the inlet fluid temperature exceeds the ambient temperature by 601F with 250 BTU per square foot per hour. Pressure head loss of a single panel must not exceed 0.14 feet water at recom mended flow rate. Collector shall have multi -plate design to allow for moisture ventilation of the mounting surface and wind relief during adverse weather conditions. Collector mounfing shall consist of 18-8 chromium -nickel stainless steel mounting hardware with a minimum of two continuous transverse straps having black polypropylene coating. Transverse straps shall be fastened with 18.8 chromium - nickel stainless steel damps and brackets. Water connections shall be made with hose sections made from EPDM (ethylene- propylene- diene-terpolymer) 70 durometer minimum hardness. Hose damps shall be all stainless worm gear type with 188 chromium -nickel stainless band. The collectors shall meet or exceed the minimum standards established by the Florida Solar Energy Center, other applicable nationally recognized standards, and shall be manufactured in the U.S.A.. i CERTIFICATIONS, APPROVALS & TESTING Solar Industries Solar Pool Heating Systems meet or exceed the criteria for approvals from the following accredited independent laloratories and agencies: • International Association of • Florida Solar Energy Center r Plumbing and Mechanical • Dade County Officials (IAPMO) . City of Los Angeles • National Sanitation Foundation • DOE- Bright Way Program } 90% W Q 80% Z W 60% W CL 50% U 40 W 30,E U U' 20% W 10% 0% Instant�ta e'o Efficiency of Solar Industries Collectors rq'I'Solar W W N Industries uA Industries through: oe in Solar Pool ,Heat ng,Systenis rMthed USA -.10 0 .10 .20 .30 .40 tf,i-ta 0E -HR -F11 I BTU soIorindustries.(om CITY OF LA QUINTA BUILDING & SAFETY DEPT.. APPRO V C"FED ®4108 Solar Industrie EWLT' ( ABY Part No. 19280 r S%JiRJP. 2901 Alejo Rd., Palm Springs, CA 92262 (1 -HUB Accelerator Campus) 760-325-3000. Contract Agreement Solar Pool Heating System Installation for Bella Cristia You are entitled to a completely filled in copy of this agreement, signed by both you and the contractor, before any work may be started, THIS AGREEMENT made the 21 t day of November, 2014 has been made between SunUp Solar Systems, Inc., License.#992607, hereinafter called the 'Contractor," and Bella Cnstia hereinafter called the 'Buyer,* for the project located at the following address: 78705 Avenida La Torres, CA 92253. The Contractor agrees to provide the following labor, materials, and installation for the Buyer and the Buyer agrees to purchase the following: Description of Project • Provide and install three solar pool heating systems, each system to include the following: o (11) 4' X 12' and (5) 4' X 10' SunUp (Aquatherm) unglazed solar thermal collectors. o Pentair SolarTouch controller (with noctumal cooling mode) to control solar pool heating system operation. o Pentair IntelliFlo Variable speed pool pump o Pentair Motorized diverter valve - integrated with solar control system and sensors. • Provide and properly, install system per CSI Program requirements. • Exterior piping will be painted to matchthe stucco. - • Provide and install all necessary valves, vacuum breakers, and connections for each: pool. • Provide City of La Quinta Building Permit. • Make systems operational and provide operating instructions and manuals to Buyer. Installed Price for each system: $16,002 CSI Rebate: $16,002 Net Cost: $0 Upon receipt of an executed contract, deposit check, HOA Federal Tax ID number, and recent gas bill, SunUp will complete the CSI Application as soon as possible. SunUp agrees the deposit is 100% fully refundable in the event the CSI Rebate is substantially reduced and Buyer decides to cancel the contract. Buyer to verify CSI Rebate: amount equals the contract price before proceeding with project. The annual energy savings are 2286 Therms. Please see the table below for the estimated incentive for your. calculation for each program step. The current program steps are also displayed below. a 1 eentiye�EstiAli ddw rN: nc ntive43 1 $7.00 $16,002.00 r-'� INITIAL rPlease refer to http://www.csithermal-comicalculator/commercial/resul Uc6517c9ab22e 42b7 aOaa b64b73alf43b/ for more information. Terms: Deposit Order of Materials $6,500 Start-up(Cfty final Approval) $4,500 Total System Price: $16,002 Warranties $5,000 �,�C�► � /. , � Receipt of CSI Rebate $ 502 Sunup (Aquatherm) Collectors 10 year limited:warranty. Pentair SolarTouch Controller & Pump 3 year limited warranty Labor and Maintenance Agreement 3 year full warranty • SunUp to provide biannual inspections of system for 3 years from date of installation and make repairs as necessary at no cost to Buyer, INFORMATION ABOUT THE CONTRACTORS STATE LICENSE BOARD (CSLB) CSLB is the state consumer protection agency that licenses and regulates construction contractors. Contact CSLB for information about the licensed contractor you are considering, including information about disclosable complaints, disciplinary actions and civil judgments that are reported to CSLB. Use only licensed contractors. If you file a complaint against a licensed contractor within the legal deadline (usually four years), CSLB has authority to investigate the complaint. If you use an unlicensed contractor, CSLB may not be able to help you resolve your complaint. Your only remedy may be in civil court, and you may be liable for damages arising out of any injuries to the unlicensed contractor or the unlicensed contractor's employees. For more information: VISIT CSLB's website at www.cslb.ca'.gov CALL CSLB at 1-800-321-CSLB (2752) WRITE CSLB at P.O. Box 26000, Sacramento, CA 95826 START AND COMPLETION OF WORK The work to be performed under this Contract shall be commence approximately 30 days after Buyer verifies the CSI Rebate equals contract price. The Project shall be completed approximately 25 days. after start date, subject to permissible delays as defined in this contract. Failure of the Contractor, without lawful excuse, to substantially commence work -within 20 days from the start date, is a violation of Contractors License Law. Contractor shall be deemed to have substantially commenced work when contractor moves equipment;or material onto the jobsite. INI TERMS AND CONDITIONS '-DELAYS IN INSTALLATION Buyer agrees that Contractor and Contractor's installers are not responsible for delays in delivery or installation due to weather, fire, strikes, shortages, war, terrorism, government or utility regulations or permitting or inspection delays. ACCESS Buyer agrees to allow and provide Contractor and his/her equipment access to the property. PAYMENT Buyer agrees to pay Contractor the total price, according to the schedule set forth on Contract, including any change orders or extras caused by unforeseen conditions or requests of the Buyer. Upon request Contractor shall furnish a statutory unconditional waiver and release form prior to receipt of the next payment. Contractor will charge at the rate of 1.5% per month for all balance past due per the Payment Schedule. Buyer agrees to pay all collection costs (including attorney fees and court costs) incurred by the Contractor to collect past due amounts. WARRANTY INFORMATION Contractor provides a limited warranty on all labor and system installation for five (5) years from date of system commissioning and warrants such to be free from any defects in workmanship and/or materials. Contractor will replace or repair at its sole discretion any item it determines to be faulty as a result of errors and/or omissions on the part of the Contractor. This warranty does not apply to conditions resulting from normal wear and tear, vandalism and/or natural catastrophes. Should any entity and/or individual perform any work, service or maintenance to any portion of the solar system other than the Contractor, this warranty will be voided. Routine cleaning of solar collectors is not considered work, service or maintenance for purposes of this agreement. UNFORESEEN CONDITIONS If unforeseen or concealed conditions are discovered, or if actual conditions are materially different than as represented by the Buyer, then Contractor shall be entitled to a mutually agreeable change order adjusting the price and/or time for completion to accommodate such conditions. ADDITIONAL WORK & CHANGE ORDERS Buyer may order additional work or changes in writing at any time. Any additional work or changes will be completed ona time and material basis. The Buyer will be required to pay the Contractor the sum of $85.00 per hour for every man- hour associated with any additional work or change. The Buyer will also be responsible for the cost of any additional equipment and materials required plus a 10% handling charge. No extra work will be performed without formal written documentation signed by the Buyer directing the Contractor to proceed with the additional work or changes per the pricing provided by this section. The Buyer shall pay for any additional work or changes within 10 calendar days from the date the work is completed. All work will cease until any required payments are made. Any existing code violations at property that prohibit or impede the Contractor's ability to complete scope of work will be repaired at the Buyer's expense on a time and material basis. Buyer is responsible for equipment once equipment is delivered to property address. Contractor is not responsible for vandalism, theft, or damage to equipment caused by others or Acts of God. ENERGY PRODUCTION Contractor is not responsible for changes in the amount of energy generated or therms produced by installed system due to obstructions to the sun such as trees, towers, building or other obstructions, changes in customer's water heating and/or space heating usage, or changes in environmental conditions such as weather, precipitation, smoke, fog, cloud cover or air pollution. RIGHT TO STOP WORK Contractor shall have the right to stop work if any payment shall not be made, when due, to Contractor under this Agreement; Contractor may keep the job idle until all payments due are received. Failure to make payment, within ten (10) days of the date due, is a material breach of this Agreement and will entitle Contractor to cease any further work. CLEAN UP Contractor will remove from Owner's property debris and surplus material created by his operation and leaves it in a neat and broom clean condition. ASBESTOS AND HAZARDOUS WASTE Unless the contract specifically calls for the removal, disturbance, or transportation of asbestos or other hazardous substances, the parties acknowledge that such work requires special procedures, precautions and/or licenses. Therefore, unless the contract specifically calls for same, if Contractor encounters such substances, Contractor shall immediately stop work and allow the Owner to obtain a duly qualified asbestos and/or INITIAL JLJ�-- 3 `J 4hazar0us material contractor to perform the work or do the work himself at Contractor's option. Said work will be treated as an extra under this contract. \,ASBESTOS, LEAD, MOLD, AND OTHER HAZARDOUS MATERIALS Owner hereby represents that Owner has no knowledge of the existence on or in any portion of the premises affected by the Project of any asbestos, lead paint, mold (including all types of microbial matter or microbiological contamination, mildew or fungus), or other hazardous materials. Testing for the existence of mold and other hazardous materials shall only be performed as expressly stated in writing. Contractor shall not be testing or performing any work whatsoever in an area that is not identified in the Scope of Work. Unless the contract specifically calls for the removal, disturbance, or transportation of asbestos, polychlorinated biphenyl (PCB), mold, lead paint, or other hazardous substances or materials, the parties acknowledge that such work requires special procedures, precautions, and/or licenses. Therefore, unless the contract specifically calls for same, if Contractor encounters such substances, Contractor shall immediately stop work and allow the Owner to obtain a duly qualified asbestos and/or hazardous material contractor to perform the work or Contractor may perform the work itself at Contractor's option. Said work will be treated as an extra under this contract, and the Contract Term setting forth the time for completion of the project may be delayed. In the event that mold or microbial contamination is removed by Contractor, Owner understands and agrees that due to the unpredictable characteristics of mold and microbial contamination, Contractor shall not be responsible for any recurring incidents of mold or microbial contamination appearing in the same or any adjacent location, subsequent to the completion of the work performed by Contractor. Owner agrees to hold Contractor harmless, and shall indemnify Contractor harmless for any recurrence of mold or microbial contamination. Owner also agrees that Contractor shall not be responsible, and agrees to hold Contractor harmless and indemnify Contractor, for the existence of mold or microbial contamination in any area that Contractor was not contracted to test and/or remediate. Further, Owner is hereby informed, and hereby acknowledges, that most insurers expressly disclaim coverage for any actual or alleged damages arising from mold or microbial contamination. Contractor makes no representations whatsoever as to coverage for mold contamination, though at Owner's: additional expense, if requested in writing, Contractor will inquire as to the availability of additional coverage for such contamination or remediation, and if available, will obtain such coverage if the additional premium is paid for by Owner as an extra. ARBITRATION OF DISPUTES ANY CONTROVERSY OR CLAIM ARISING OUT OF OR RELATED TO THIS CONTRACT, OR THE BREACH THEREOF, SHALL BE SETTLED BY BINDING ARBITRATION IN ACCORDANCE WITH THE CONSTRUCTION INDUSTRY ARBITRATION RULES OF THE AMERICAN ARBITRATION ASSOCIATION, AND JUDGMENT UPON THE AWARD RENDERED BY THE ARBITRATOR(S) MAY BE ENTERED IN ANY COURT HAVING JURISDICTION THEREOF. CLAIMS WITHIN THE MONETARY LIMIT OF THE SMALL CLAIMS COURT SHALL BE LITIGATED IN SUCH COURT AT THE REQUEST OF EITHER PARTY, SO LONG AS BOTH PARTIES LIMIT THEIR RIGHT TO RECOVERY TO THE JURISDICTION OF THE SMALL CLAIMS COURT. ANY CLAIM FILED IN SMALL CLAIMS COURT SHALL NOT BE DEEMED TO BE A WAIVER OF THE RIGHT TO ARBITRATE, AND IF A COUNTER CLAIM IN EXCESS OF THE JURISDICTION OF THE SMALL CLAIMS COURT IS FILED IN THE MUNICIPAL OR SUPERIOR COURT, THEN THE PARTY FILING IN SMALL CLAIMS COURT MAY DEMAND ARBITRATION PURSUANT TO THIS PARAGRAPH. NOTICE: BY INITIALING IN THE SPACE BELOW YOU ARE AGREEING TO HAVE ANY DISPUTE ARISING OUT OF THE MATTERS INCLUDED IN THE 'ARBITRATION OF DISPUTES' PROVISION DECIDED BY NEUTRAL ARBITRATION AS PROVIDED BY CALIFORNIA LAW AND YOU ARE GIVING UP ANY RIGHTS YOU MIGHT POSSESS TO HAVE THE DISPUTE LITIGATED IN A COURT OR JURY TRIAL. BY INITIALING IN THE SPACE BELOW YOU ARE GIVING UP JUDICIAL RIGHTS TO DISCOVERY AND APPEAL, UNLESS THOSE RIGHTS ARE SPECIFICALLY INCLUDED IN THE 'ARBITRATION OF DISPUTES' PROVISION. IF YOU REFUSE TO SUBMIT TO ARBITRATION AFTER AGREEING TO THIS PROVISION, YOU MAY BE COMPELLED TO ARBITRATE UNDER THE AUTHORITY OF THE BUSINESS AND PROFESSIONS CODE OR OTHER APPLICABLE LAWS. YOUR AGREEMENT TO THIS ARBITRATION PROVISION IS VOLUNTARY. WE HAVE READ AND UNDERSTAND THE FOREGOING AND AGREE TO SUBMIT DISPUTES ARISING OUT OF THE MATTERS INCLUDED IN THE 'ARBITRATION OF DISPUTES' PROVISION TO NEUTRAL ARBITRATION. INIT I AGREE TO ARBITRATION. OWNER'S INITIALS I AGREE TO ARBITRATION, CONTRACTOR'S INITIALS WORKERS' COMPENSATION INSURANCE The Contractor carries workers' compensation in, for all employees. This contract represents the entire agreement of Contractor and Buyer and supersedes oral or written agreements. Changes to the terms of this Proposal and Contract must be in writing and expressly signed by Buyer and Contractor to have any effect. SunUp Solar Systems, Inc. Owner or authorized Officer Dated: ILI-7,41,4 Print: Sign: INITIAL' Bella Crisba Authorized Officer. Dated: i Print: (-j? c, Sign: S Bin # City�f La QC;i�i��itC�. -Building &r Safety Division P.O. Box 1504, 78-49S Calle Tampico . La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address:71-1i�s Owner's Name: Address: RgF44 CR I fy'//} A. )5 A iF 16fzJP rArr 7,05 /°rvLw�l� L o/iRr A. P. Number: T Legal Description: City, ST, Zip: ZS3 . Contractor: n1 U s Telephone: 61)Z 75--Z / Address: ��6�/ Z (f /v�C� 1,1 �2 Project Description: OVL City,.ST, Zip: —tau NTA C A 9-L7V (/L� �/ G� r'X/lTiNlr i�STGiz7 Telephone: r G 8SS r State Lic # :.... Z6Q 7 City Lie . Arch., Engr., Designer:. AIL %fid%/r"14io Address: City., ST, Zip: 'a2 -� 1 ><>:::?>::>:»:::>::>-<>::::< <:;>. •ConTelePhone.7 aneY tructi n Type: Occupancy: State Lic: #:: A ffr J h'Pa (circle one): : New Add'n ]ter Repair Demo. Name of Contact Pe.rson: �� �o Ttryryq,J Sq. Ft.: J# Stories: # Units: Telephone#,of Contact Person: d' , b 2 —o %7 Estimated Value of Project• /6 P 012-- 2APPLICANT: APPLICANT:DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING. PERMIT FEES. Plan Sets Plan Check submitted Item Amount Structural Cates. Reviewed, ready for corrections. Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction . Flood.plain plan. Plans resubmitted Mechanical. 'Grading plan ° 2°" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Decd Plans picked up S.M.I. H.O.A. Approval Plans resubmitted :Grading IN If OUSE:- 'rd Review, ready for correctionstissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue SCIi661 Feer Total Permit fees