Loading...
07-0710 (AR)S, P.O. BOX 1504. 78=495 CALLE TAMPICO LA QUINTA; CALIFORNIA 92253 Application Number: Property Address: - - APN: Application description f Property Zoning; Application valuation: Applicant: P7.000007101 44930 TORTOLA CIR 604-274-004-91 -23913 ADDITION.- RESIDENTIAL LOW DENSITY RESIDENTIAL .6617 Tit1v144aQ"-- BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect.or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: - - - - - - - - - = - - - - - Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the ' following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or sheds licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged'exemption. Any violation of Section 7031.5 by any pplicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves'thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he, or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State Licen w.). ( ) Lam exempt under Sec. , B. fair this reason ,Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.I. Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: TOM CARROLL_. 44930 TORTOLA CIRCLE LA QUINTA, CA 92253 Other struct info . . ... C Contractor: Owner DITION. Lic. No.: ------ Date: 3/08/07 WORKER'S COMPENSkTf6N DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for whichthis permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: carrier. Carrier NPolicy Number E FOOTAGE I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I shoo Tne subject the workers' compensation provisions of Section 337�100 of the La \ odej I shall forthw' ply with thos provisions. i Date:3��! /Applicant: - WARNING: FAILURE TO. SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 9. Each person upon, whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being - performed under or following issuance of this permit. 2. Any permit issued as a result of this application b null and void if work is not commenced within 180 days from date of issuance of permit, or essation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and stat that th above information is correct. I agree to comply with all city and c my rdinances and state laws relatin to bui ing construction, n ereby authoriz representatives oft c my enter upon the above-mentioned rope y for inspection urp ses. J/'�J //1'� Dat v v�fSignature-(Applicant-or�Agentl: Application Number .''07-00000710 Permit BUILDING PERMIT Additional desc Permit Fee . . 90.00 Plan Check Fee 58.50 Issue Date Valuation . . 6617 Expiration Date 9/04/07 Qty Unit Charge Per Extension BASE FEE 45:00 - 5..00 9:0000 THOU BLDG 2,001-25,000 ---------------------------------------------------------------------------- 45.00 Permit . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 21.16 Plan Check.Fee 5.29 Issue Date Valuation . . . 0 Expiration Date 9/04/07 Qty, Unit Charge Per Extension. - BASE FEE 15.00 176.00.. .0350 ELEC>NEW RES - 1 OR .2 FAMILY 6.16 Permit . .. MECHANICAL Additional desc . Permit Fee . . . . 33.0.0 Plan Check Fee 8.25 Issue Date - Valuation 0 Expiration Date .9/04/07 Qty Unit Charge Per Extension BASE .FEE 1.5.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000EA MECH B/C <=3HP/100K BTU 9.00. Special`Notes and Comments convert garage to office space 176 sq." ft. March 8, 2007 8:48:18 AM jjohnson EE Other Fees . . . ENERGY REVIEW FEE- STRONG STRONG MOTION (SMI) - RES .66 Fee summary. Charged Paid Credited Due Permit Fee Total 144.16 .00 .00 144.16 Plan Check Total. 72.04 .00 0-0 72.04 . Other Fee Total 6.51 .00 .00 6.51 Grand Total 222.71 .00 .00 222.71 LQPERMIT - Bin # C)�- 2co Permit # Project Address: A. P. Number. Contractor: Construction Type: Address: City, ST, Zip: New Add'n Alter Repair Demo Telephone: Sq. Ft.: State Lie. #': # Units: Arch., Engr., Designer; Estimated Value Af Project: Z W - Address: City, ST, Zip: Telephone- PERMIT FEES State Lic. #: Name of Contact Person: Telephone # of Contact Person: -7 Item Amount . # Submittal Req'd Reed Plan Sets Stractaral Calcs. Truss Calcs. Energy Caics. Flood plain plan Grading, pliin• Subcoutactor List . Grant Deed H.O.A. Approval IN HOUSE-, Planning Approval Pub. Wks. Appr School Fees 'Nun Gav: ivr,nt' . L City Of La Quinta Building 8i Safety DlvWon P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking.Sheet Owner's Name:"�/Vi �rQl Address: %3 0 OCT c City, ST, Zip: G` 1r (✓+ Z 2A53 Telephone:— Project Description: Lie. #: �I L-%T� Construction Type: Occupancy: ProJect type (circle one): New Add'n Alter Repair Demo ✓0 1 Sq. Ft.: # Stories: # Units: ' � d0 Estimated Value Af Project: Z W - APPLICANT: DO NOT WRITE BELOW THIS UNE TRACIMG • PERMIT FEES Plan Check submitted Item Amount . Reviewed, ready for corrections Plan Check Deposit Called Contact Pesos Plan Check Balance Plans Picked.ap Constraction Plans resubmitted . Mechanical 2-' RevIT, ready for eorrectio so I p Electrical Called Contact Person / I� 0 Plumbing Plans picked up F �rr S.M.L Plans resubmitted Grading Review, ready for. correctionsrssae Developer Impact Fee Called Contact Person A.LP.P. .Date of permit issue Total Permit Fees CERTIFICATE OF COMPLIANCE JDsc Desert Sands Unified School District 47950 Dune Palms Road ¢ BERMUDA DUNES r' rA RANCHO MIRAGE d Date 3/8/07 La Quinta, CA 92253 INDIAN WELLS P No. 29271 (760) 771-8515 d� LA QU -��INO 0 Owner Tom Carroll APN # 604-274-004 i` Address 44930 Tortola Circle Jurisdiction La Quinta City La Quinta Zip Permit # Tract # Study Area' Type Residential Addition No. of Units 1 Lot # No.. Street S.F. Lot # No. Street S.F. Unit 1 44930 Tortola Circle 176 Unit 6 Unit 2 Unit 7 Unit 3 . Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 00 square feet, detached accessory, structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determ ried thatahe above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school -facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. -in the amount of $0.00 X 176 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Tim Spear Check No. Name on the check Telephone 952.457.4114 Funding Exempt By Dr. Doris Wilson Superintendent�= .41 / Fee collected /exempt bySh McGil ey Payment Recd $0.00 r sO.ver/Uideir" - Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will sa rve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on ich the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity oriied to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original- Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting P 1; OWNER/BUILDER INFORMATION Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "Owner/Builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the City or County. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection. If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $200.00 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. If you are an employer, you must register with the State and Federal Government as an employer and you are subject to several obligations include State and Federal income tax withholding, federal social security taxes, worker's compensation insurance, disability insurance costs and unemployment compensation contributions. There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. For more specific information about your obligations under Federal Law, contact the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "Owner/Builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits`are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board in your community or at 1020 N. Street, Sacramento, California 95814. Please complete and return the enclosed owner -builder verification form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. Very truly yours, CITY OF LA QUINTA DEPT. OF BUILDING AND SAFETY 78-495 Calle Tampico , La Quinta, CA 92253 (7 0) 777-7012 F : (760 - 011 OWNER'S SIGNATURE/DATE PROPERTY ADDRESS (� D PERMIT NUMBE (S) A RE INSPECTION WILL BE CHARGED I F- OF $30 PLANS AND 10B .CAR 0 VON , ROLL THE SITE FOR A 44�v. N EDA INSPECTION. `r0 r -to /a C rA QUINT NO EXCEPTION cavi ni'a. 97 Z5AFE OEFT ®VE® .A p g RUCTION APIV oO - �l � "®o4 .AN ADEQUATELY SIZED ALL REQUIRED ON THE !OB SITE DURING PHASES CONST UCTION AND MUST BE EMPTIED ARY. FAI MAY CAUSE THE CI TO HAVE THE CO AIRF; DUMPED AT THE 'PENSE OF THE �xr. west\ R60 On ori PU.R POS e b =am Pur poc cC 2;#114" rare wail 5/$ .T`iPt; X To R?13 insNt��O� i Construction is NOT E on the following :ode Dr. Martin Luliier I President's Day Memorial Day Independence.Day Labor Day Veteran's Day Thanksgiving Cay Christmas Day CONSTRUCTION HOURS Oct> lt- "O"I Mon ay - Fri ay: 7:00 a.m. to .5:30 ;� Saturday: 8:00 a.m. to.5:00 p.m Sunday: None Government Code Holidays: Nona May 1 st - September 30th Monday - Friday: 6:10 a.m. to 7:00 p. MII 10:D ' idays: Jr. Day (CLOSP.+ ) tA101 t4NatNq • Door i . �►r 17 - �_._._. - __ _ ... ._... �•S . - -EXE-Vt*NY'�% — -_- TV' 1,., X 14 Y2 l Q-13 ini5c, &V o 8' 9"e�ILin9C��P� R -l9 -FurPmSlr/� 5 A!C watt un► eba ht rr - 2.9 . C E.s'►i�q �pi{ON L Box 4e cTitc 3Bo i ::...: ` v R-6 %&GIJVATWAN ,x 414 wint�ow EXT , IV 01Sk rfERA CcoQ EXr g' ovEleHEA o I�ooR' Ip' i Aj ID ir x 4 0 r a nTrco,,te. d mom p`ot-e. w wrm, StHcCo ©g; re.b��� i I I I LE I NOT C1� A G: 3TIZ TIT �^ ova �.,.. .. � t Uvv .0 A G: 3TIZ TIT 4 TITLE 24 (REPORT Title 24 Report for:' Carroll Residence 44930 Tortola Circle La Quinta, CA FF((c C'0� Project Designer:. CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED. FOR CONSTRUCTION DAT 0 By rep ed y: Joan D. Hacker Insu-form, Inc. 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 (760) 779-065.7 Job Number: Date: 3/7/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency.Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number. 2655 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 7 HVAC System Heating and Cooling Loads Summary g Room Load Summary 10 EnergyPro 4.3 by EnergySoft Job Number: User Number. 2655 El Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Carroll Residence _ 3/7/2007 Project Title Date 44930 Tortola C'irr IP I a Qijenta Project Address Building Permit # lnsu-form- Inc: (760) 779-0657 Documentation Author Telephone Plan Check/Date Co n-ce Method Climate ZoneField Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.04 10.16 -6:12 Space Cooling 92.85 77.36 15.49 Fans 10.41 10.12 0.29 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 107.30 97.64 9.66 Percent better than Standard: 9.0% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: (k Single Family FXI Addition Total Conditioned Floor Area: 175 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (W) 270 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 175 ft2 Fenestration: Average Ceiling Height: 8.0 ft Area: 16 ft 2 Avg. U: 0.87 Number of Dwelling Units: 0.20 Ratio: 9.1% Avg. SHGC: 0.70 Number of Stories: 1 BUILDING ZONE INFORMATION Zone Name Floor Area 1 Mrig 7one 175 # of Volume Units Zone Type OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wnnd 64 0102—R -13_—S=0_0_ 97n A Wall Wood 140 n 1Q2 R-13 'R -n n _Q_9 Will Wnod 140 x_102 R_13 R-00 180 go, Rnnf Wnnd 17.5 n n4s R_19 R -n 0 97n _Q Thermostat Vent . Type Hgt. Area sethnnk 2 n/a Gains Condition rrY��/ N Status JA IV Reference Location / Comments EX 1:1 New- 99-A3 Additinn I. ❑New 09-A3 Addition Xfq� ❑New 09-A3 Addition l4 QNew n1 -A14 Additinn ❑❑ ❑❑ F-1 1-1 ❑❑ ❑❑ F] F-1 ❑❑ ❑❑ ❑❑ EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number. Page:3 of 10 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Carroll Residence 3/7/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-.0SHGC2 Azm. Tilt Stat. Glazing Type Comments --I— Window Front 0&,) 16 0 0_870 NERC 0,70 NERr- 270 _9.Q New Double Mtl Uncoated n fa ilt Addition 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhanq__ Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt Dist Len Hgt Dist Len Hgt 1 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 18 None No Insulation 26-A1 New Addition Run Initiation Time: 03/07/07 11:41:27 Run Code: 1173296487 EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number. Page:4 of 10 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Carroll Residence 3/7/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Living Zone Room Heat Pump 5.95 HSPF Room PTAC without Side 8.7 EER New Setback Louvers HVAC DISTRIBUTION Location Duct Duct Condition Ducts Cooling Location R -Value Status Tested? Living Zone Ductless /with Ductless n/a n/a New No Fan Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS GUMIJUANGE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name Title/Firm: Address: Telephone: Lic. #: (signature) (date) Enforcement Agency . Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Joan D. Hacker Title/Firm: Insu-form, Inc. Address: 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 Telephone: (760) 779-0657 (sign ureJ ' ` ` (date) STAMP Certificate Of Compliance : Residential (Part 4 of 4) CFA R Carroll Residence 3/7/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention -to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the —4—Y — �No 01 Juaun�auUn anu uucunwinduon suomiaea. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- �nnr —A NERC n.n..irle...c:nr. rcr ......-....-A -.-Ji_-.._ :.__u__ _--`1-- --' __---. ._ Plan I Field - -- --- - ---- ---....I _.._..._.....,................---.........,.�..,-.�r,,..�.. — � 1.. � ��. I Plan Field installation certificate. The HVAC System "Living Zone" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. EnergyPro 4.3 by EnergySoft User Number. 2655 Job Number: Pape:6 of 10 1 Mandatory -Wasures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ❑ 191 ENFORCE - permit application documentation. NIA DESIGNER MENT Building Envelope Measures ❑ ❑K ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ 0 ❑ , § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑K ❑ apply to exterior mass walls)' ❑ E ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: ❑ Q ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑K ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑K ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑K ❑ § 150(f):' Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑K ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑. § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ penneance rate no greater than 2.0 perm/inch. ❑ ❑ ❑ § 118: Insulation specked or installed meets insulation installation quality standards. Indicate type and include ElElCF-6R EK Form: ❑ ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/ExFltration Controls. Page:7 of 10 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ Q ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑K ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑K ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ 191 ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ 0 ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑K ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ EK ❑ . having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ E ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes'closest to water heater tank, non -recirculating systems, and entire ❑ Q ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ N ❑ indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ 0 ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ EK ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:7 of 10 R Mandatory Measures Summary: Residential (Page 2 of 2) ' MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ X❑ ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ § 114: Pool and Spa Heating Systems and Equipment X❑ ❑ ® ❑ ® ❑ ® ❑ ❑x ❑ 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria J ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ Q ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined El [g] Elin Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ R ❑ controlled by an occupant sensor that complies with Section 1' 9(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ AI ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8. or. more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. " § 150(k)B: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:8 of 10 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Carroll Residence 3/7/2007 SYSTEM NAME FLOOR AREA Living Zone 175 ENGINEERING CHECKS _ SYSTEM LOAD Number of Systems 1 Heating System Output per System 11,000 Total Output (Btuh) 11,000 Output (Btuh/sgft) 62.9 Cooling System Output per System 11,500 Total Output (Btuh) 11,500 Total Output (Tons) 1.0 EA 26.0 OF 310� Outside Air 0 cfm 70.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAKJ I COIL HTG. PEAK CFM I Sensiblel Latent I I CFM TSensible 6,385F----7940 3625 CARRIER 52EQA2123 9,502 0 6,870 Total Adjusted System Output 9,5021 0 6,870 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am SYCHROMETRICS (Airstream Tem 70.0 of 70.0 of ® 91.5 of Supply Fan Heating Coil 300 cfm of Heatina Pea Supply Air Ducts 91.5 of ROOMS 70.0 of b Return Air Ducts i DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 of 78.0 / 60.1 of 78.0 / 60.1 of 48.2 / 46.8 of O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 48.2 / 46.8 of 300 cfm 34.6% R.H. ROOMS 78.0/60.1 of 78.0 / 60.1 of Return AirDucts I 4.3 by EnergySoft User Number. 2655 Job Number. 9of10 ROOM LOAD SUMMARY PROJECT NAME Carroll Residence DATE 3/7/2007 SYSTEM NAME Living Zone FLOOR AREA 175 ROOM'LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM I SENSIBLE LATENT CFM SENSIBLE *LATENT CFM SENSIBLE ' Addition Addition 1 202 6,385 940 202 6,385 940 158 i 3,625 PAGE TOTAL 1 202 6,385 940 158 3,625 TOTAL 1 202 6,385 940 158 3,625 EnergyPro By EnergySoft User Number: User Job Number: Page: 10 of 10 '