Loading...
BRES2017-0038VOICE (760) 777-7125 78-495 CALLE TAMPICO O�i � D LA QUINTA, CALIFORNIA 92253 DESIGN &DEVELOPMENT DEPARTMENT FAX (760) 777-7011 FAX (760) 777-7153 BUILDING PERMIT Date: 5/10/2017 Application Number: BRES2017-0038® Owner: Property Address: 55615 TURNBERRY WAY ® ® NORMAN AND ANDREA THORLAKSON APN: 767550012 19452 JASPER HILL RD Application Description: THORAKSON / CHANGE SITTIN IN VASITA TO BED AND BA TRABUCO CANYON, CA 92679 Property Zoning: AY 0 9 2017 Application Valuation: $2,500.00 - . . CITY OF Applicant: DESIGNANDDEVECQP 4NfTQEpART contractor: ANDREA THORLAKSON " MENT SEA COUNTRY CONSTRUCTION SERVICES 19452 JASPER HILL RD 27241 JARDINES TRABUCO CANYON, CA 92679 MISSION VIEJO, CA 92692 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 789587 Date: "J'/.// -- / / Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 ofthe Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( 11, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 11, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: (949)636-1150 Llc. No.: 789587 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: EXEMPT Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3 0 of abor Co e, I all forthwith comply with those provisions. Date: T� Applicant: / ,lam WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application'and state that the above information is correct. I agree to ti comply with all city and county ordinances and statelaws7rel ��y construction, and hereby authorize representatives ofthis ci e above-mentioned property for inspection,purposes. Date: ��IO�G% Signature (Applicant or Agent Date: 5/10/2017 . Application Number: BRES2017-0038 Owner: Property Address: 55615 TURNBERRY WAY NORMAN AND ANDREA THORLAKSON APN: 767550012 19452 JASPER HILL RD Application Description: THORAKSON / CHANGE SITTING ROOM IN CASITA TO BED AND BATH TRABUCO CANYON, CA 92679 Property Zoning: Application Valuation: $2,500.00 f Applicant: Contractor: ANDREA THORLAKSON SEA COUNTRY CONSTRUCTION SERVICES 19452 JASPER HILL RD 27241 JARDINES TRABUCO CANYON, CA 92679 MISSION VIEJO, CA 92692 (949)636-1150 . --------------------------------------------------------------------------------------------- Llc. No.: 789587 Detail: 564 SQ.FT. CASITA REMODEL. THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016 CALIFORNIA,BUILDING CODES. Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF . 101-0000-42403 0 $152.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $50.16 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $202.16 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $50.68 DESCRIPTION ACCOUNT QTY AMOUNT I FIXTURE/TRAP PC 101-0000-42600 0 $50.68 Total Paid for PLUMBING FEES: $101.36 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $22.80 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $18.24 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 100 SF 101-0000-42400 0 $51.68 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $141.36 Total Paid for REMODEL: $234.08 DESCRIPTION ACCOUNT QTY AMOUNT SMI -RESIDENTIAL 101-0000-20308 0 $0.50 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.50 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Bin # Permit # . Y5 201�� 6b3 7. Project Address-b4L Qty of La Qu*lata Building 81- Safety Division 78-495 Calle Tampico La Quinta; CA 92253 - (760) 777-701,2 Building Permit Application and Tracking Sheet Owner's Name: A. P. Number: h $ Address: L ` ,f tp -I/ Legal Description: ' . r r L �j ' City, ST, Zip:. rQ, leiAn- C4 n ra r: o t C ct o i i . Tele hone: P a Address: "Project Description: i r C ty ST, Zip: — r -- p e - Teleh onfe State Lic. # : City Lie. #c `Arch.,'Engr., Designer: 'Address: City, ST, Zip: Telephone: tructi n TYPCon 'Occupancy: State Lic. !. Alter Repair.ai circle one n r Demo Name of Contact Person: 74Ad� �!`�7t q t. #Stories: # Units: Telephone # of Contact Person:19 ��' –Estimated Value of Project: �00 ` APPLICANT: DO. NOT WRITE BELOW THIS LINE 0 Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance, Title N Calcs. Plans picked up Construction ' Flood plain plan Plans resubmitted Mechanical Grading plan 2" Revicw, ready for corrections/issue Electrical-. Subcontactor List Called Contact Person Plumbing Grant Aced Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN ROUSE:- Reyiew, ready for corrections/issue. Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue SCt,00l Fees, Total Permit Fees WR 10 2017 CITY OF LA 014KTQ ' COMMUNITY DEVELOPMENT CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Thorlakson Calculation Date/Time: 17:03, Thu, Mar 09, 2017 Calculation Description: Input File Name: Thorlakson.ribd16 CF1 R -PRF -01 Page 1 of 7 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Thorlakson 04 05 02 Calculation Description 08 Energy Use (kTDV/ft2-yr) 03 Project Location 55615 Turnberry Compliance Margin Percent Improvement 04 City La Quinta, CA 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.2.1 (695) 08 Climate Zone CZ15 09 Software Version CBECC-Res 2016.2.1 (868) 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 564 15 Number of Zones 1 16 Slab Area (ft2) 564 . 17 . Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 0 21 Glazing Percentage (%) 23.4% COMPLIANCE RESULTS LA QLANTA 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates. one or more Special Features shown below APPROVED I rUhi uulvo I tiuu 1 IUIV I REQUIRED SPECIAL FEATURES A ' ORE The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins RECEIVE • Exposed slab floor in conditioned zone Registration Number: Registration Date/Time: MAR 10 2017 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 CITY OF LA(a11INTA COMMUNITY DEVELOPMENT APR 10 2017 HERS Provider: Report Gener2S 8F7-9 cn4INTa COMMUNITY DEVELOPMENT ENERGY USE SUMMARY 04 05 06 08 Energy Use (kTDV/ft2-yr) Standard Design ..Proposed Design Compliance Margin Percent Improvement Space Heating 3.58 2.84 0.74 20.7% Space Cooling 300.36 299.01 1.35 0.4% IAQ Ventilation 8.15 8.15 0.00 0.0% Water Heating 34.24 34.24 0.00 0.0% Photovoltaic Offset -- 0.00 0.00 -- Compliance Energy Total 346.33 344.24 2.09 0.6% REQUIRED SPECIAL FEATURES A ' ORE The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins RECEIVE • Exposed slab floor in conditioned zone Registration Number: Registration Date/Time: MAR 10 2017 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 CITY OF LA(a11INTA COMMUNITY DEVELOPMENT APR 10 2017 HERS Provider: Report Gener2S 8F7-9 cn4INTa COMMUNITY DEVELOPMENT CERTIFICATE OF COMPLIANCE - RESIDENTIAL PER COMPLIANCE METHOD Project Name: Thorlakson Calculation Date/Time: 17:03, Thu, Mar 09, 2017 Calculation Description: Input File Name: Thorlakson.ribd16 C F1 R -PRF -01 Page 2 of 7 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting -the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • --None-- Cooling System Verifications: • -- None -- HVAC Distribution System Verifications: • -- None -- Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms . Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Thorlakson 564 1 2 1" 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC System 1 564 10 DHW System 1 front wall OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition front wall Zone 1 exterior walls 90 Front 183 18 90 Existing No back wall Zone 1 exterior walls 270 Back 183 0 90 Existing No left wall Zone 1 exterior walls 180 Left 330 100 90 Existing No right wall Zone 1 exterior walls 0 Right 330 14 90 Existing No Ceiling (below attic) 1 Zone 1 ceiling 564 Existing No Registration Number: Registration DateRme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-09 17:03:39 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Thorlakson Calculation Description: Calculation Date/Time: 17:03, Thu, Mar 09, 2017 Input File Name: Thorlakson.ribd16 CFI R -PRF -01 Page 3 of 7 ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance. Roof Emittance Radiant Barrier Cool ' Roof Status Verified Existing Condition Attic 1 Roof Ventilated 3 0.1 0.85 Yes No Existing No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Name- Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition Bed 2 front front wall (Front -90) 3.0 6.0 1 18.0 0.58 0.65 Insect Screen (default) Existing No front door left wall (Left -180) 3.0 8.0 1 24.0 0.58 0.65 None Existing No Bed 1 french left wall (Left -180) 2.5 8.0 2 40.0 0.38 0.35 Insect Screen (default) New N/A Bed 2 left left wall (Left -180) 3.0 6.0 2 36.0 0.58 0.65 Insect Screen (default) Existing No Bed 2 bath - right wall (Right -0) 3.0 1.0 2 6.0 0.31 0.37 None New N/A Bed 1 bath right wall (Right -0) 2.0 4.0 1 8.0 0.58 0.65 Insect Screen (default) I Existing No OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Bed 2 front 1 2 8 7.5 0 0 0 0 0 0 0 0 0 front door 2 2 26 5 0 0 0 0 0 0 0 0 0 Bed 1 french 1 2 5 24 0 0 0 0 0 0 0 0 0 Bed 2 left 1 2 16.5 11 0 0 0 0 0 0 0 0 0 Bed 2 bath 1 2 8.5, 19 0 0 0 0 0 0 0 0 0 Bed 1 bath 1 2 22 10 0 0 0 0 0 0 0 0 0 ., Registration Number: Registration DateRme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017.-695 Report Generated at: 2017-03-09 17:03:39 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Thorlakson Calculation Description: Calculation Date/Time: 17:03, Thu, Mar 09, 2017 Input File Name: Thorlakson.ribdl6 CFI R -PRF -01 Page 4 of 7 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 .08 09 Name Zone Total Cavity Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 102.6 None .0 No Existing No • Cavity / Frame: no insut 12x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Roof Attic Roofs Wood Framed Ceiling in. O.C. none 0.616 Roofing: 10 PSF (RoofTile) • Inside Finish: Gypsum Board • Cavity/Frame: R -19/2x6 • Sheathing/Insulation: Wood Siding/sheathing/decking exterior walls Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.068 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 ceiling attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. SLAB FLOORS 01 02 03 04 05 06 07 .08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Slab On Grade 1 Zone 1 564 102.6 None .0 No Existing No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required -- WATER HEATING SYSTEMS 01 •. 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction M) Status Verified Existing Condition DHW System 1 DHW Standard Water Heater 1 1 none - Existing No Registration Number: Registration DateMme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-09 17:03:39 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Thorlakson Calculation Date/Time: 17:03, Thu, Mar 09, 2017 Calculation Description: Input File Name: Thorlakson.ribd16 CFI R -PRF -01 Page 5 of 7 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Energy Factor or Efficiency Input Rating/Pilot Tank Insulation R -value (Int/Ext) Standby Loss / Recovery Eff NEEA Heat Pump. Type Tank Location or Ambient Condition Water Heater 1 Gas Small Storage 1 50 0.6 EF 40000 Btu/hr n/a n/a Na n/a Distribution System 1 (Ventilated and specified) 4.2 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Heating System Cooling System Name System Type Name Ducted Name Ducted Distribution System Fan System Floor Area Served Status Verified Existing Condition HVAC System 1 Other Heating and Cooling.System Heating System 1 Yes Cooling System 1 Yes Distribution System 1 HVAC Fan System 1 564 Existing No HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating System 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency Zonally Controlled Multi -speed Compressor Name System Type EER SEER HERS Verification Cooling System 1 SplitAirCond - Split air conditioning system 11.7 14 No No N/A HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Ducts located in attic Existing (not Distribution System 1 (Ventilated and specified) 4.2 Attic Attic None Existing No N/A Unventilated) Registration Number: Registration Date/Time: HERS Provider: ' CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-09 17:03:39 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEWETHOD CF1R-PRF-01 Project Name:_Thorlakson -Calculation Date/Time: 17:03, Thu, Mar 09, 2017 Page 6 of 7 Calculation Description: Input File Name: Thorlakson.ribd16 , IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM '• IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 1-1 50 Exhaust 0 Not Required SFam IAQVentRpt 1-2 50 Exhaust 0 Not Required Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards -. 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-09 17:03:39 ' CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Thorlakson Calculation Date/Time: 17:03, Thu, Mar 09, 2017 Calculation Description: Input File Name: Thorlakson.ribd16 CF1 R -PRF -01 Page 7 of 7 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation r Signature: Melanie Diebolt Company: Signature Date: Design Concepts 3-9-17 Address: CEA/HERS Certification Identification (If applicable): 57445 29 Palms Hwy Suite 304 City/State/Zip: Phone: Yucca Valley, CA 92284 760-365-8742 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Brian Diebolt Company: Date Signed: Design Concepts 3-9-17 Address: License: 57445 29 Palms Hwy Suite 304 City/State/Zip: Phone: Yucca Valley, CA 92284 760-365-8742 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-09 17:03:39 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. "Exceptions may apply. (Original 08120161 Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per NFRC400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use LI -factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-13 for compliance and must be caulked and/or weatherstri ed.' § 110.7- Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF1R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U -factor must not exceed 0.043. Minimum R-19 or weighted average U -factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.* § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R -value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or LI -factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly LI -factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.' § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U -factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). § 150.0(g)1: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). § 150.0(8)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q�' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum LI -factor of 0.58; or the weighted averse U -factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)1 B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)1C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.* § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool ands a heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in § 150.0(h)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers K required, as specified by manufacturers instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution i in for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher 9 required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic„tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1818 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/< inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross-sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0 m 12. 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow_ 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy :5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central .forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(0): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic ' testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)l: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or. built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p) Pool Systems and Equipment Installation: Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)lA: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)lC: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated tem erature•must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)l D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. 'Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)l E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).* Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1G: with Reference Joint Appendix JA8. Installed lamps must be marked with °JA8-2016" d "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)l H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. ' § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5(f); and meets all other re uirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § .130.5(9; and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must . be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JA8, except luminaires in closets less than 70 square feet and luminaires in hallways.* § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, -balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0(k)3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in §§ 110.9,.130.0, 130.2, 130.4, 140.7 and 141.0. ' § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles persite must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 wafts of ower as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B:'- • i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)l: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the . requirements of § 110.10(b) through § 110.10(e). § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)l: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' " § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the'vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point'of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.10 c must be provided to the occupant. § 110.10(e)l: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric".