Loading...
08-1255 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: * IxATW Ct-"' 08-00001255 55705 TURNBERRY WY 767-550-015- - - ADDITION - RESIDENTIAL LOW DENSITY RESIDENTIAL 150000 c&ht 4 4 " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect or Engineer: A. LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business an rofess als Code, and my License is in full force and effect. License Class: B icense No.: 505442 Dater ;K es✓n Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of. the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penally of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C:). Lender's Name: _ Lender's Address LQPEILIIIT Owner: SUNSERI JAMES 55705 TURNBERRY LA QUINTA, CA 92253 ( 9700 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/18/08 Contractor: U CE DURKTON, MARK ��J 20ca 69683 PLEASANT GROV CATHEDRAL CITY, CA 4 C/p, CQUlNT.Q (760)328-7276 EDEpT Lic. No.: 505442 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION ' I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become sub' o t 'ars. compensation provisions of Section 3700 of the Labor od I shall for with comply with t se provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATIO AGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above informs ' is correct. I a to comply with all city and county ordinances and state laws relating to building construe , nd hereby horize resentatives of this county to enter upon the above-mentioned property f r i e on purposes. Date:,, -1 Signature (Applicant or Agent): Application Number . . 08-00001255 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 814.50 Plan Check Fee 529.43 Issue Date Valuation . . . . 150000 Expiration Date 3/17/09 Qty Unit Charge Per Extension BASE FEE 639.50 50.00 ---------------------------------------------------------------------------- 3.5000 THOU, BLDG 100,001-500,000 175.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 32.85 Plan Check Fee 8.21 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/17/09 Qty Unit Charge Per Extension BASE FEE 15.00 510.00 ---------------------------------------------------------------------------- .0350 ELEC NEW RES - 1 OR 2 FAMILY 17.85 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/17/09 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit MECHANICAL Additional desc . Permit Fee . . . . 3'9.50 Plan Check Fee 9.88 Issue Date . . . . Valuation . . 0 Expiration Date 3/17/09 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 ----------------- ----------------------------------------'------------------ 6.5000 EA MECH VENT FAN 6.50 Permit . . . PLUMBING Additional desc . LQPERMIT - Application Number . . . . . 08-00001255 - Permit PLUMBING Permit Fee . . . . 54.00 Plan Check Fee 13.50 Issue Date Valuation 0 Expiration Date 3/17/09 Qty Unit Charge 'Per Extension BASE FEE 15.00 5.00 6.0000 EA PLB FIXTURE 30.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 2.00 3.0000 EA PLB GAS PIPE .1-4 OUTLETS 6.00 ------------- Special Notes and Comments 510 SQ. FT. ADDITION WITH PATIOS AND RELOCATE BBQ AREA.. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ..ENERGY REVIEW FEE 52.94 STRONG MOTION (SMI) - RES 15.00 Fee summary Charged Paid Credited Due -----------F----- ---------- -------------------- ---------- Permit Fee Total 955.85 .00 .00 955.85 Plan Check Total 561.02 .00 .00 561.02 Other Fee Total 67.94 .00 .00 67.94 Grand Total 1584.81 .00 .00 1584.81 LQPERAIIT F - 77, {F �. Bin #. Cityof ' La Qulnta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: GS -4o5 — O 0 P_ Owner's Name: A. P. Number: Address: 7k) �-t_3 C' (Z- (Z'_( Legal Description: City, ST, Zip: Contractor: M D Go �N S'. Telephone: � Address: 9%6_3 PLE N5 A N Project Description: City, ST, Zip: G G) 2 Z 3 Tele Telephone: p 5 d R' ) State Lic. # : (� 2 . City Lic. #: Arch , Engr. Designer: 6\ t moi✓ L�L�—T� Address: 4t O lx/ EV w/�UC City, ST, Zip: T, CIA G 2Z i Telephone: 6to _..1000 , State Lic. #: � l� � `��-` � Name of Contact Person: M P � U 1� VO) (�� Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair. Demo Sq. Ft.: SnD # Stories: # Units: Telephone # of Contact Person: vj 4'( D Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal r Req'd Rec'd TRACKING , PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cates. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up �� d Construction Flood plain plan Plans resubmitted La Mechanical Grading plan 2°d Review, readycorrect' issue 9 Electrical Subcontactor List Called Contact Person 9 Plumbing Grant Deed Plans picked up r -3 S.M.I. Ii.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''" Review, ready for correctios/iss Developer Impact Fee Planning Approval Called Contact Person p, Pub. Wks. Appr Date of permit issue School Fees �? 09 Total Perm' ees AIS +ems («.A� ctt.M) Ila ire 11STPDX Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760)-398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: a.. DATE: RECEIPT: CHECK N: rNITIALs: CERTIFICATE OF COMPLIANCE (California Education Code 17620) ti Project Name: James Sunseri (Greg Norman CC) 1 Date: 08/19/08 Owner's Name: James Sunseri Phone No. ( Project Address: 55-705 Turnberry Way, La Quinta, CA 92253 Project Description: Residential Addition APN: 767-550-015 Tract #: Type of Development: Residential XXi Commercial Lot #'s: Industrial Total Square Feet of Building Area: 510 sq. Ft. Certification of Applicant/Owners: The person signing certifies at a e mformatio ' correct and makes this statement under penalty of perjury and further represents that he/she is autholize t si n tehalf of the owreloper. 1 / \ 1 ,.� Dated: 08/19/08 Signature: *********************************************************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. K= 510 sq. ft. Amount per Sq.Ft. $ 2.97 Amount Collected $ 1,514.70 Building Permit Application Completed: Yes/N6 By: Carey M. Carlson, Asst. Supt., Support Services Certificate issued by: Leticia C. Torres, Facilities AnalystSign Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the<time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of "a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. LT:c/n»•docs/devfees/certificate of compliance fomi tablesTO IJSE.doc 1/16/03 T � _1 Earth Systems Southwest 79-811 B Count Club Drive 1� _ - Country Bermuda Dunes, CA 92203 (760) 345-1588 (800) 924-7015 FAX (760) 345-7315 DAILY REPORT OF INSPECTION OF CONCRETE SB/RS CO. GOV. UBC TITLE 21/24 OTHER Building Permit No.: DSA Application No.: Date of Inspection: Project Name: Job No.: Project Address: S�70S �Ul�N3F%z/�% c.�.•9 Y �� ©�/�->'rt Architect: Structural Engineer: General Contractor: 134z,3 k2 4 /A Sub Contractor: TYPE OF INSPECTION: Reinforcing Placement Other Description of Work Inspected: F lo X X -.442.4191' /¢ �' �i4 T! � �• U � /tom Gc/ C� L! //� �'�-� Unresolved Items: Descriptive Location of Sample: Slump: Water Added: Air Contest, %:— Field I.D. Marking: Concrete Temp Air Temp Unit Wt.: Time in Mixer: Specified Strength: - Sample Time: Supplier: Admixture:_ _ Mix Design: Truck #: # of Samples: — I hereby certify that I have inspected all of the above reported work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications and applicable building laws. Final report issued at project completion. Copy 1 ESSW Lab Copy 2 Project Superintendent Copy 3 Governing Agency O%0/ % / Inspector's Name/No.z& 4�'-P % Inspector's Signature All inspections based on a minimum of 4 hours; over 4 hours will be an 8 hour minimum. In a� „-anq`inspection extending past 12 p.m. will be an 8 hour minimum. ive 4 Contractor's Representat j TITLE 24 REPORT Title 24 Report for: The Sunseri Residence --05 CITY OF LA QUINTS- Turnberry Way Quints, CA 92253 f BUILDING & SAFETY DEPT. APPROVED . FOR CONSTRLI&MN 7,77foject Designer: Mark Durkton Construction Inc. 69683 Pleasant Grove Cathedral City, CA 92234 (760) 578-4940 Report Prepared By: Michael Faugno BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Job Number: Date: 7/23/2008 JUL j 4 2008 The EnergyPro computer program has been used to perform the calculations summarized in this compliant e_report This=program has a 1proval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 3665 I+ TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 10 HVAC System Heating and Cooling Loads Summary 12 Room Load Summary 15 Room Heating Peak Loads 18 Room Cooling Peak Loads 23 LI 0 EnergyPro 4.4 by EnergySoft Job Number: User Number: 3665 Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R _The_S_u.n.ser_i-Res.i.de.n.Ce (XJ Single Family ❑ Addition2 Total Conditioned Floor Area: 7-/23120-08 Project Title Area ❑ Multi Family [X] Existing + Add/Alt Date _5.5=7-05_T_ur_n.be.r_ry_W_ _ay La_Qu.inta ft2 Building Front Orientation: (E) 90 deg Project Address Wall_ 0 ft2 Building Permit # _B_REEZE-I.R-CQNDITI0-141 G Natural Gas (760) 346-0855 Wood_ Documentation Author ft2 Fenestration: Telephone plan Check/Date _Ener g_y_Pso 155_ 14.5 CAC1i.mateZon_e 15 Area: Field Check/Date Compliance Method Number of Dwelling Units: _0..025_ -B 3.8_ _R-_0...0_ Climate Zone 0. TDV Standard Proposed Compliance 09.0 (kBtu/sf-yr) Design Design Margin # of Space Heating 4.67 4.85 -0.18 Floor Area Volume Space Cooling 110.72 107.12 3.61 .HVAC#_1 Fans 15.15 14.66 0.49 2 Domestic Hot Water 5.99 7.19 -1.20 _0..25_ Conditioned_ Pumps 0.00 0.00 0.00 9.0.9.0 Totals 136.54 133.82 2.72 _nLa better than Standard: Building Type: (XJ Single Family ❑ Addition2 Total Conditioned Floor Area: 4,285 ft Area ❑ Multi Family [X] Existing + Add/Alt Existing Floor Area: .Roof 3,775 ft2 Building Front Orientation: (E) 90 deg Raised Floor Area: Wall_ 0 ft2 Fuel Type: 0__9.0. Natural Gas Slab on Grade Area: Wood_ 4,285 ft2 Fenestration: Existing- Wall_ Average Ceiling Height: 155_ 14.5 ft Area: 1,121 ft 2 Avg. U: 0.48 Number of Dwelling Units: _0..025_ -B 3.8_ _R-_0...0_ 1.00 0. Ratio: 26.2% Avg. SHGC: 0.41 Number of Stories: 09.0 1 Wall_ BUILDING ZONE INFORMATION 1.52_ # of Thermostat Vent Zone Name Wood_ Floor Area Volume Units Zone Type Type Hgt. Area .HVAC#_1 1.,_4.9.8_ 9,846 13,9.4.9 -0..66_ Conditioned- -Setback_ 2 -n/a .HVAC#2 _0..024_ JZ1.9_ _RR0..0_ 1,.0.57 13,31.8 _0..25_ Conditioned_ -Setback- 2 _n/.a HVA.G_#3 9.0.9.0 382 4,813 0.09_ Conditioned_ Setback_ 2 _nLa OPAQUE SURFACES Insulation Act. . Type Frame Area LI -Fac. Cay. Cont. Azm. Tilt .Roof Wood- 510_ _0_025_ -R_38_ _-E=0_0_ -345_ 0 Wall_ Wood_ 262_ _0..0.7-4_ _R-1.9_ __20_0_ 0__9.0. Existing- Wall_ Wood_ 27-4_ _0..074_ _R=J_9_ _R0...0_ _9.0__90 Existing- Wall_ Wood_ 155_ _0._0.74 -R-19_ X0.0.1.80_ Zone #2 9.0 _Roof Wood_ 8.3.8_ _0..025_ -B 3.8_ _R-_0...0_ _3.4.5_ 0. Wall_ Wood_ 449 -0-07-4- -EZ1.9 _R 0_O 0_ 09.0 # -4 -Existing- Wall_ Wood_ 1.52_ _0_074 -RA -9_-R=0.0_ 1.8.0__9.0. Existing- Wall_ Wood_ 119_ _0._074 _EZ1.9_-EL-0_0_-27-0_ 7 - 9.0 _Roof Wood_ 1.,_4.9.8_ _0..025_ _17-38_ _R=0...0_ _345_ 0 Wall_ Wood_ 37_4 _0..024_ JZ1.9_ _RR0..0_ -0--90 Wall_ Wood- _26.4_ _0_074 _- X0.0_ 9.0.9.0 Wall_ Wood -1,031-0-0.7-4- -R_19_ _R=0..0_ 180__9.0 Wall_ Wood_ 4.58_ _0._0.7-4_ _R-1.9_ _Z0..0_ _27-0_ 9.0 _Roof Wood_ 1.,0.5.5_ _0..025_ -R_3.8_ _R_0..0 _345_ 0. Wall_ Wood_ 5.5.8_ _0..0.7_4_ _R-1.9_ _R=0..0_ _0_90 Wall_ Wood_ 97.2_ _0..07-4_ _R-1.9 X0...0_ 9.0_ 9.0 Wall_ Wood_ 351 _0._0.7_4_ _R_1.9_ JR=0..0_ 180_ 9.0 Wall_ Wood- 627__0..07-4__R_1.9_�0.0_-270_ 9.0 .Roof Wood_ 382_ _0_025.17-38_ X0..0_ -345_ 0 Wall_ Wood_ 30.6_ _0..0.7_4_ _R-19 _R=0..0 0__9.0 Wall_ Wood_ 1_4_4_ _0..024_ _RZ1.9_ _R=0..0_ _90__9.0. Wall_ Wood_ 21.2_ _0...0.7_4_ _R-1.9_ _R 0...0_ 1.80__90 Wall_ Wood_ 1.9.0_ _0._024_ -2_1.9 _IZ0..0_ _2.7_0__9.0 Gains Condition Y / N Status JA IV Reference Location / Comments New _0.1-&.1.8 Zone #1 N.ew _09=A5 Zone_#1 N.ew _09=&5 Zone -#J New _0.9A.9 Zone 1 Existing- _01At8 Zone- #_1 Existing_ _09=&5 Zone_#1 Existing_ _0.9=A5 Zone_#_1 Existing- _0.9&5 Zon1 Existing- _01=A18 Zone_#2 Existing- _0.9=A5 Zone - #2 -Existing- _0.9A5 Zone #2 Existing_ _0.9=A5 7-one-#2- Existing- _0.9=A5 Zone -#2 Existing- _0.1-&1.8 Zone-#-4- one_#4Existing_ Existing- _0.9=A5 Zone- # -4 -Existing- _0.9=A5 Zone_#_4 Existing- _0.9A5 Zone_#_4 Existing- _0.9A5 Zone- # -4 -Existing- _01=A1.8 7 - one -#.3 -Existing- 0.9=A5 Zone_#3 Existing- _0.9&5 Zone - #3 -Existing- _09=A5 Zone - #3 -Existing- _0.9=A5 Zone_#3 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Paae:3 of 31 1 9 Bug Screen 0.76 10 Bug Screen 0.76 11 ` Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R The Sunseri Residence 12 Bug Screen 0.76 7/23/2008 Project Title 0.76 14 Bug Screen Date 15 FENESTRATION SURFACES 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 True Cond. Location/ # Type Area LI -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 1_ WindcwRight_(N)_ 4.5_ -0-3.0.0 -NFRC- _0_33 -NERC 0_ _9.0-N.ewMilgard Vinyl_(6cd.)-(.3.01.6.) _Zone -#1 2 Window Right (N)_ 4.5 0.300 NFRC 0_33 NFRC 0 90 New Milgard Vin ylF( xd)_3(_016) Zone #1 3 Window Right (N)_ 4.5 0.300 NFRC 0_33 NFRC 0 90 New Milgard Vinyl (Fxd)_ 3( 016) Zone #1 4 Window Front (E)_ 4.5 0.300 NFRC 0_33 NFRC 90 90 New Milgard Vinyl (Fxd)_3( 016) Zone #1 5 Window Front (E)_ 4.5 0.300 NFRC 0_33 NFRC 90 90 New Milgard Vinyl (Fxd)_3( 016) Zone #1 6 Window Front (E)_ 4.5 0.300 NFRC 0_33 NFRC 90 90 New Milgard Vinyl (Fxd) (3016) Zone #1 7 Window Left (S)_ 120.0 0.55 NFRC 0.32 NERC 180 90 New Fleetwood Norwood 3000 (15-0 Zone #1 8 Window Right (N)_ 4.5 0.300 NFRC 0.33 NFRC 0 90 Existing_Milgard Vinyl (Fxd) (3016) Zone #1 9 Window Right (N)_ 4.5 0.300 NFRC 0.33 NFRC 0 90 Existinq_Milgar Vinyl (Ex )_(3016) Zone #1 _1.0 Window Right (N)_ 4.5 0.300 NFRC M. NFRC 0 90 Existinq_Milgard Vinv�Fxd)_(3016) Zone #1 J Window Right (N)_ 4.5 0.300 NFRC 0_33 NFRC 090 Existing_Milgard Vinyl (Fx_(3016) Zone #1 12 Window Right (N)_ 9.0 0.300 NFRC 0_33 NFRC 0 90 Existing_Milgard Vinyl (Fxd) 6016 Zone #1 13. Window -Right -(N.)_ 30:0 Q 300_NERC 0.33 .NERC 0_ _90 Existing -M. ilgar_d_V_inyl-(.Fxd)_(.6050) _Zone -k1 14 Window Left (S)_ 9.0 0.300 NFRC 0_33 NFRC 180 90 Existin _Milgard Vinyl (Fxd)_6( 016)_ Zone #1 15 Window Left U 45.0 0.550 NFRC 0_32 NFRC 180 90 Existing_Fleetwood Norwood 3000 (59710)_ Zone #1 16 Window Rear (W)_ 4.5 0.300 NFRC 0_33 NFRC 270 90 Existing_Milgard VinylF( xd)_3( 016)- Zone #1 17 Window Rear U 18.0 0.300 NFRC 0_33 _NFRC. 270 90 Existing_Milgard Vinyl F( xd)_ 3( 060) Zone #1 18 Window Rear (W)_ 9.0 0.300 NFRC 0_33 NFRC 270 90 Existing_Milgard Vinyl F( xd)_6( 016) Zone #1 19 Window Resnr (W)- _36_0 -0-. K0 NFRC 0-. 3 3 NFRC 270 90_ Exi t5 ing_Milgard Vinyl (Fxd)_(f9_60) Zone #1 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 Bug Screen 0.76 8 Buq Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES R -Val. Insulation Location Condition Location/ JA IV Reference Status Comments Slab Perimeter 90 None No Insulation 26-A1 New Zone #1 Slab Perimeter 137 None No Insulation 26-A1 Existing Zone #1 Slab Perimeter 204 None No Insulation 26-A1 Existing Zone #2 Slab Perimeter 180 None No Insulation 26-A1 Existing Zone #4 Slab Perimeter 80 None No Insulation 26-A1 Existing Zone #3 Run Initiation Time: 07/23/08 11:03:04 Run Code: 1216836184 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page:4 of 31 it Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R The Sunseri Residence 7/23/2008 Project Title Date FENESTRATION SURFACES True Cond. Location/ Area U -Factor' SHGC2 Azm. Tilt Stat. Glazinq Twe Comments .20. 21 Window Rear(W)_ Window Rear (W)_ 4..5_ 18.0 -0.200 NERC 0..3.3 0.300 NFRC 0_33 22 Window Right (N) 3.8 0.300 NFRC 0_33 23 Window Right (N) 12.5 0.300 NFRC 0_33 24 Window Right (N)_ 9.8 0.300 NFRC 0_33 25 Window Right (N)_ 32.5 0.300 NFRC 0_33 26 Window Right (N)_ 3_8 0_300 NFRC U3 27 Window Right (N) 12.5 0.300 NFRC 0_33 28 Window Right (N)_ 28.0 0.300 NFRC 0.33 29 Window Front (E)_ 90 0 0.30 NFRC 0.33 30 Window Front (E)_ 9.0 0.300 NFRC 0_33 31 Window Front (E)_ 9.0 0.300 NFRC 0_33 32. 33 Window F_r_ont_(E.)_ Window Left -48-0 (S_ 2.3 0.1Z0J16=A. 0.59 0.300 NFRC 0_33 34 Window Left U 2.3 0.300 NFRC 0_33 35 Window Left (SS_ 2.3 0.300 NFRC 0_33 36 Window Left (S_ 2.3 0.300 NFRC 0_33 37 Window Left U 2.3 0.300 NFRC 0_33 38 Window Left (S)_ 2.3 0.300 NFRC 0_.33 NERC _270_ NFRC 270 _90_ Existing_Milgard_V_inyl_(Exd)_(.3.0.1.6.) 90 Existing_ilgard Vinyl (Fxd) 3( 060) _Zone -#1 Zone #1 NFRC 0 90 Existing_M�ard Vinyl F( xd)_(2616) Zone #2 NFRC 0 90 Existing_Milgard Vinyl (Fxd)2( 650) Zone #2 NFRC 0 90 Existin _Milgard Vinyl (Fxd)_ 6( 616)_ Zone #2 NFRC 0 90 Existin4_Milgard Vinyl (Fxd) (6650) Zone #2 NFRC 0 NFRC 0 90 Exisfl�cn _Milt' ra d Vinyl (Fxd)_(2§16) 90 Existing Milgard Vinyl (Fxd)_2( 650) ane #2 Zone #2 NFRC 0 90 Existin _Milgard Vinyl (Fxd)-(Q) Zone #2 NFRC 90 NFRC 90 -90 Existing_Mi�CI rd Vinyl (Fxd)_(6. 0-50) 90 Existing_Milgard Vinyl (Fxd)_(6016) Zone #2 Zone #2 NFRC 90 90 Existing_Milgard Vinyl (Fxd)_6( 016)_ Zone #2 1_1.60.90_ NFRC 180 _90 Existing_Default_Dbl_Mtl_Tint(.3wng)_(.6080)__Zor.e-#2 90 Existin _Milgard VinylF( xd)1( 616)_ Zone #2 NFRC 180 90 Existing_Milgard Vinyl(Fxd)_ 1( 616) Zone #2 NFRC 180 90 Existing-Milgard Vinyl (Fxd)_ 1{ 616) Zone #2 _NERC 180 90 Existing_Milgard Vinyl (Fxd_1( 616) Zone #2 NFRC 180 90 Existing_Milgard Vinyl (Fxd)_1( 616) Zone #2 NFR _ 180 90 Existina_Milgard Any (F cix )_(1616) Zone #2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 1.6 2.6 8.0 0.1 8.0 8.0 23 Bug Screen 0.76 5_0 2.6 8_0 0.1 8.0 8.0 24 Bug Screen 0.76 1.6 6.6 8.0 0.1 8.0 8.0 25 Bug Screen 0.76 5.0 Q. 8.0 1.0 8 p 8.0 _ 26 Bug Screen 0.76 1.6 2.6 8.0 0.1 8.0 8.0 27 Bug Screen 0.76 5.0 2.6 8.0 0.1 8.0 8.0 28 Bug Screen 0.76 29 Bug Screen 0.76 5.0 6.0 10.0 0.1 10.0 _ 10.0 30 Bug Screen 0.76 1.6 6.0 10.0 0.1 10.0 10.0 31 Bug Screen 0.76 1.6 6.0 10.0 0.1 10.0 10.0 32 Bug Screen 0.76 8.0 6.0 10.0 0.1 10.0 10.0 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 07/23/08 11.03.04 Run Code: 1216836184 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page:5 of 31 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R The Sunseri Residence 7/23/2008 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments _39. 40 Wiod.ow Left_(.S.)_ Window Left _2.3_ U 6.0 -0-3.0.0-NERC--0.33 _N.EPC 0.300 NFRC 0_33 NFRC 1.8.0_ 180 _9.0 Existing_Milgard Viny.L(F-xd.)_(1.61.6.) 90 Existing_Milgard Vinyl (Fxd,_2( 030) _Zone_#2 Zone #2 41 Window Rear (W)_ 12.0 0.300 NFRC 0_33 NFRC 270 90 Existing_Milgard Vinyl (Fxd_8( 016)_ Zone #2 42 Window Rear (W)_ 60.0 0.770 116-A 0_59 116-6 270 90 Existing_Default Dbl Mtl Tint S( GD)_ 7( 8710) Zone #2 43 Window Rear (_W)_ 12.0 0.300 NFRC 0_33 NFRC 270 90 Existing_Milgard Vinyl (ftd_(8016) Zone #2 44 Window Rear (W)_ 60.0 0.770 116-A 0_59 116-B 270 90 Existing_ Default Dbl Mtl Tint(SGD)_ 7( 8710)_ Zone #2 45 46 Window Window Rearr(W)_ Rear (W) 28.0 12.0 __D.300 NFRC 083 NFRC_ 0.300 NFRC 0.33 NFRC 270 270 90 Exi ting_Milgard Vinyl (Fxd)_(4-070) 90 Existing Milgard Vinyl (Fxd)_8( 016) Zone #2 Zone #2 47 Window Rear (W)_ 60.0 0.77 11 Q-A 0_59 -116-B 27090 Exi ting_ efault Dbl Mtl Tint(SGD)_(78710_)_ Zone #2 48. 49 Skylight Window Right Front (IV)_ (E)_ 2.2 21.4 1.470 11C --A 0.7f 116_B 0.770 116-A 0_59 116-B 345 90 0 Exi�g_D�It Non -Metal Skylight Zone #4 90 Existing -Default Dbl Mtl Tint(Swng)_(2880)_ Zone #4 50 Window Front (E)_ 28.0 0.770 116-A 0_59 116-B 90 90 Existing -Default Dbl Mtl Tint(Swng)_ 3( 680)__ Zone #4 51_ 52 Window Window F_r_ont_(E.)_ Front (E)_ 18.0 4.5 -0300 -N-.ER--C 0-33 _NFRC 0.300 NFRC 0_33 NFRC 90_ 90 _90 Existing_Milgard_Vinyl-(F-xd.)_(.3060) 90 Existing_Milgard VinylF( xd)3( 016)_ Z.one-#_4 Zone #4 53 Window Front (E)_ 18.0 0.300 NFRC 0_33 NFRC 90 90 Existing_Milgard Vinvl (Fx,_3( 060) Zone #4 54 Window Front (E)_ 4.5 0.300 NFRC 0_33 NFRC 90 90 Existing_Milgard Vinyl (Fxd)_ 3( 016) Zone #4 55 Window Front (E) 18.0 0.300 NFRC 0_33 _NERC. 90 90 Existing_Milgard Vinyl (Fxd)_ 3( 060) Zone #4 56 Window Front U 4.5 0.300 NFRC 0_33 NFRC 90 90 Existing_Milgard Vinyl (F�_ 3( 016) Zone #4 57 1. Indicate Window Left (S)_ 18.0 0.300 NFRC 0_33 NFRC1$Q 90 Existing _Milgard Vinyl (Fxd)_(_3060) source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. Zone #4 INTERIOR AND EXTERIOR SHADING Window 0.76 0.76 0.76 Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 1.6 8.0 10.0 0.1 10.0 10.0 42 Bug Screen 0.76 7.8 7.8 10.Q 01 10_Q 10_o 43 Bug Screen 0.76 1.6 8.0 10.0 0.1 10.0 10.0 44 Bug Screen 0.76 7.87.8 10.0 0.1 10.0 10.0 45 Bug Screen 0.76 7.0 4.0 9.0 0.1 9.0 9.0 46 Bug Screen 0.76 1.6 8.0 9.0 0.1 9.0 9.0 47 Bug Screen 0.76 7.1 7.8 9.0 0.1 9.0 9.0 48 None 1.00 49 Buci Screen 0.76 50 51 52 Bug Screen Bug Screen Bug Screen 0.76 0.76 0.76 53 Bug Screen 0.76 54 55 Bug Screen Bug Screen 0.76 0.76 56 Bug Screen 0.76 57 Buo Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 07/23/08 11:03:04 Run Code: 1216836184 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page:6 of 31 ` Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R The Sunseri Residence 7/23/2008 Project Title Date FENESTRATION SURFACES 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. - Overhang Len. Hgt. LExt. REA Left Fin Right Fin Dist. Len. Hgt. Dist. Len. Hgt. 58 Bug Screen ,• 0.76 True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments 58. Wind.owLeft=(-S-)_ 4...5_ _0_3-00-NF_RC__0..3-3 _N.F_RC. x:8.0_ _9.0_ Existing_Milgard_V_inyl_(.F-xd)_(.3.0j6) _Zone -#4 59 Window Left (S) 18.0 0.300 NFRC 0_33 NFRC 180 90 Existing_Milgard Vinyl Fxd_ 3( 060) Zone #4 60 Window Left " (S)_ 4.5 0.300 NFRC 0_33 NFRC 180 90 Existing_Milgard Vinyl (Fxd)_(3016) Zone #4 61 Window Rear (W)_ 15.0 0.300 NFRC 0_33 NFRC 270 90 Existing_Milgard Vinyl (Fxd)_3( 050) Zone #4 62 Window -Rear (W)_ 15.0 0.300 NFRC 0_33 NFRC 270 90 Existing_Milgard Vinyl 0_c3050) Zone #4 63 Window Rear- (W)_ 15.0 0.300 NFRC 0_33 NFRC 270 90 Existing_Milgard Vinyl (Fxd)_(3050) Zone #4 ' 64 Window Rear(W)_ 94 -0.100 NFRC 0_39 NFRC 270_ 9_0_ Exi is ing_Milg r VinyL(Fxd)_("60?6) Zone #4 65 Window Rear (W) 48.0 0.770 116-A 0_59 116-B 270 90 Existing Default Dbl Mtl Tint(Swng)6( 080) Zone #4 66 Window Left (S)_ 2.3_ 0_300 NFRC 0_33 NFRC 180- 90 Existing Milg rd Vinyl (Fxd)_(1616) Zone #3 67_ Window Left (S)_ 2.3 0.309 NFRC 0_33 NFRC 180 90 Existing_Milgard Vinyl (Fxd)_(1616) Zone #3 68 Window Left (S)_ 2.3 0.300 NFRC 0_33 NFRC 180 90 Existing_Milgard Vinyl (Fxd)_(1616) Zone #3 69 Window Rear (W)_ ' 15.0 0.300 NFRC 0_33 NFRC 270 90 Existing_Milgard Vinyl (Fxd)_(3050) Zone #3 _7_0 Window Re--ar(-W)_-20.Q 0T_7_0)_1.6=A.0.59 116=8 _2-70_ _90 Existing_Qefa.ult_DhLM11_Tint(.Swng)-(.3068)__Zone-#3 ' Run Initiation Time: 07/23/08 11:03:04 Run Code: 1216836184 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page:7 of 31 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND.EXTERIOR SHADING Window # Exterior Shade Type SHGC Hgt. Wd. Overhang Len. Hgt. LExt. REA Left Fin Right Fin Dist. Len. Hgt. Dist. Len. Hgt. 58 Bug Screen ,• 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 62 Bug Screen 0.76 63 Bug Screen 0.76 64 Bug Screen 0.76 1.6 6.0 10.0 0.1 10.0 10.0 65 Bug Screen 0.76 8.0 6.0 10.0 0.1 10.0 10.0 . 66 Bug Screen 0.76 67 'Bug Screen 0.76 68 Bug Screen 0.76 69 Bug Screen 0.76 70 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area .Thick. Heat Inside Condition Location/ Type (sq (in.) Cap. Cond. R -Val., JA IV Reference Status Comments PERIMETER LOSSES ` Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments ' Run Initiation Time: 07/23/08 11:03:04 Run Code: 1216836184 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page:7 of 31 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R The Sunseri Residence 7/23/2008 Project Title Date, HVAC SYSTEMS Rated Tank Energy Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC -#1. Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Existing Setback HVAC -#2 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC -#3 Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Existing Setback HVAC DISTRIBUTION 0_5a- n/a n/a Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC -#1 Ducted Ducted Attic 4.2 Existing No HVAC -#2 Ducted Ducted Attic 4.2 New No HVAC -#3 Ducted Ducted Attic 4.2 Existing No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal. Small Gas No Pipe Insulation 1 40,000 50 New 0.58 n/a n/a Standard Gas 50 gal. Small Gas No Pipe Insulation 1 4p 000 _50 New 0_5a- n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ftp_ Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: MAR Y' t) 0 ex' -ybo Title/Firm: Mark Durkton Construction Inc. Address: 69683 Pleasant Grove Cathedral City CA 92234 Tele hone: (760) 578-4940 Lic. #: _ _ _ _ Z3 v (sign r (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author'' Name: Michael Faugno Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: 1760) -0 '5 . (signs ut e) ' (date) EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Paoe:8 of 31 1 Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R The Sunseri Residence 7/23/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies iasea on me auequacy or ine special tusuncauon ano aocumentation sunmittea. Plan Field The Roof "R-38 Roof' includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a Plan I Field EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page:9 of 31 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF.1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value: ❑ ❑ ❑ *§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑x ❑ apply to exterior mass walls). ❑ o ❑ �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑ ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ o ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ 0 ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ El El Form: ❑ ❑X ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ Q ❑ Coefficient (SHGC), and infiltration certification. ❑ Q ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA.. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ 0 ❑ length of recirculating sections of hot water pipes shall be insulated to Table 15013. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ Q ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 10 of 31 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1818 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. - 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑X ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ 0 ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ Q ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ O ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ Q ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑x ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ 0 ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ 0 ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 11 of 31 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Sunseri Residence 7/23/2008 SYSTEM NAME FLOOR AREA HVAC -#1 2,846 NG CHECKS Number of Systems 3 Heating System Output per System 50,000 Total Output (Btuh) 150,000 Output (Btuh/sqft) 52.7 Cooling System Output per System 56,000 Total Output (Btuh) 168,000 Total Output (Tons) 14.0 Total Output (Btuh/sqft) 59.0 Total Output (sgft/Ton) 203.3 Air System CFM per System 0 Airflow (cfm) 0 Airflow (cfm/sqft) 0.00 Airflow (cfm/Ton) 0.0 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.07 Note: values above given at ARI conditions 26.0 of —�� Outside Air 213 cfm 80.0 of OOLING S 11.0 / 77.6 of 310� Outside Air 213 cfm 72.0160.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 2,547 46,081 5,196 2,139 68,305 0 8,129 9,785 0 0 213 8,855 4,324 213 12,267 0 0 8,1291 9,785 71,193 9,520 100,141 Existing HVAC Unit 139,811 0 150,000 Total Adjusted System Output 139,811 0 150,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm IF Jan 12 am PSYCHROMETRICS (Airstream Ter 80.0 of ® 110.0 of Heating Coil k Return Air Ducts `S irstream Temperatures at' 72.0/ 0.60F . 55.0/54.10F Cooling Coil h Return Air Ducts 4 Supply Air Ducts 110.0 of ROOMS 80.0 of Supply Air Ducts 55.0/54.1OF 51.7% R.H. ROOMS 72.0 / 60.5 of 4.4 by EnergySoft User Number: 3665 Job Number: Page: 12 of 31 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 7 PROJECT NAME DATE The Sunseri Residence 7/23/2008 SYSTEM NAME FLOOR AREA HVAC -#2 1,057 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 Heating System Output per System 50,000 Total Output (Btuh) 150,000 Output (Btuh/sqft) 141.9 Cooling System Output per System 56,000 Total Output (Btuh) 168,000 Total Output (Tons) 14.0 Total Output (Btuh/sqft) 158.9 Total Output (sgftrron) 75.5 Air System CFM per System 0 Airflow (cfm) 0 Airflow (cfm/sqft) 0.00 Airflow (cfm/Ton) 0.0 Outside Air (%) 1 0.0 Outside Air (cfm/sqft) 0.08 Note: values above given at ARI conditions 26.0 of Outside Air 79 cfm 80.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent I CFM I Sensible 1,244 22,512 1,884 937 29,900 0 3,500 3,836 0 0 79 3,289 1,606 79 4,556 0 0 3,5001 3,836 32,801 31490 42,128 PSA4BD / PGF1 RA (13 SEER) 139,811 0 150,000 Total Adjusted System Output 139,811 0 150,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am YCHROMETRICS (Airstream Tem 80.0 OF 110.0 OF OOLING SYSTEM PSYCHROM 11.0 / 77.6 of A4 4 Outside Air .79 cfm 72.0/60.5 of Heating Coil h Return Air Ducts '4 72.0 / 60.6 of. 55.0 / 54.1 of % Cooling Coil h Return Air Ducts 4 Supply Air Ducts 110.0 of ROOMS 80.0 of Supply Air Ducts 55.0/54.1OF 51.7% R.H. ROOMS 72.0 / 60.5 of EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 13 of 31 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Sunseri Residence 7/23/2008 SYSTEM NAME FLOOR AREA HVAC -#3 382 ENGINEERING CHECKS (SYSTEM LOAD I Number of Systems 1 Heating System Output per System 50,000 Total Output (Btuh) 50,000 Output (Btuh/sqft) 130.9 Cooling System , Output per System 56,000 Total Output (Btuh) 56,000 Total Output (Tons) 4.7 Total Output (Btuh/sgft) 146.6 Total Output (sgft/Ton) 81.9 Air System CFM per System 0 Airflow (cfm) v 0 Airflow (cfm/sqft) 0.00 Airflow (cfm/Ton) 0.0 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.07 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts COIL COOLING PEAK 407 COIL HTG. PEAK CFM ISensiblel Latent CFM I'Sen TOTAL SYSTEM LOAD 1 11,1561 1,517 14,352 HVAC EQUIPMENT SELECTION Existing HVAC Unit '46,604 0 1 50,000 Total Adjusted System Output (Adjusted for Peak Design conditions) 46,604 0 50,000 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions „ 1EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) r _ 26.0 OF 80.0 OF 110.00F 4 Supply Air Ducts Outside Air 29 cfm 110.0 OF Heating Coil ROOMS 80.0 of 80.0 OF f Return Air Ducts . :OGLING SYSTEM PSYCHROMETRICS 11.0 / 77.6 OF Outside Air 29 cfm 0 irstream Temperatures at' 72.0/60.60F . 55.0/54.10F Cooling Coil Supply Air Ducts , 1 ' 55.0 / 54.1 of 51.7%R.H. ROOMS 72.0 / 60.5 F n 72.0 / 60.5 OF ~ Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 14 of 31 17,368 936 309 9,876 0 1,300 1,415 0 0 29 1,188 580 29 1,646 0 0 1,300 1,415 TOTAL SYSTEM LOAD 1 11,1561 1,517 14,352 HVAC EQUIPMENT SELECTION Existing HVAC Unit '46,604 0 1 50,000 Total Adjusted System Output (Adjusted for Peak Design conditions) 46,604 0 50,000 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions „ 1EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) r _ 26.0 OF 80.0 OF 110.00F 4 Supply Air Ducts Outside Air 29 cfm 110.0 OF Heating Coil ROOMS 80.0 of 80.0 OF f Return Air Ducts . :OGLING SYSTEM PSYCHROMETRICS 11.0 / 77.6 OF Outside Air 29 cfm 0 irstream Temperatures at' 72.0/60.60F . 55.0/54.10F Cooling Coil Supply Air Ducts , 1 ' 55.0 / 54.1 of 51.7%R.H. ROOMS 72.0 / 60.5 F n 72.0 / 60.5 OF ~ Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 14 of 31 ROOM LOAD SUMMARY PROJECT NAME The Sunseri Residence DATE 7/23/2008 SYSTEM NAME HVAC -#1 FLOOR AREA 2,846 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone #1 Master Suite Addition 1 491 8,884 1,116 491 8,884 1,116 411 13,128 Master Suite (Existing) 1 681 12,321 1,577 681 12,321 1,577 533 17,015 Zone #2 Existing Living 1 1 1,375 24,876 2,503 1,375 24,876 2,503 1,195 38,162 PAGE TOTAL 1 2,547 46,081 5,196 2,139 68,305 TOTAL 1 2,547 46,081 5,196 2,139 1. 68,305 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 15 of 31 ROOM LOAD SUMMARY PROJECT NAME The Sunseri Residence DATE 7/23/2008 SYSTEM NAME HVAC -#2 FLOOR AREA 1,057 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone #4 Existing Living 2 1 1,244 22,512 1,884 1,244 22,512 1,884 937 29,900 i PAGE TOTAL 1 1,244 22,512 1,884 937 29,900 TOTAL 1 1,244 22,512 1,884 937 29,900 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 16 of 31 ROOM LOAD SUMMARY PROJECT NAME The Sunseri Residence DATE 7/23/2008 SYSTEM NAME HVAC -#3 FLOOR AREA 382 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone #3 Guest Casita 1 407 7,368 936 407 7,368 936 309 9,876 PAGE TOTAL 1 407 7,368 936 309 9,876 TOTAL 1 407 7,368 936 309 9,876 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 17 of 31 ROOM HEATING PEAK LOADS Project Title Date The Sunseri Residence 17/23/2008 Room Information Desian Conditions Room Name Master Suite Time of Peak Jan 12 am Floor Area Additi% Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 80°F Conduction Area U -Value OT of Btu/hr 510.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0250 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 54 = = = = = = = = = = =-3,5-6-4 = = = = = = = = = = = = = = = = = = = = = = = = = = = = 688 261.5 0.0740 54 1,045 4.5 0.3000 54 73 4.5 0.3000 54 73 4.5 0.3000 54 73 274.0 0.0740 54 1,095 4.5 0.3000 54 73 4.5 0.3000 54 73 4.5_ 0.3000 54 73 155.0 0.0740 54 619 120.0 0.5500 perimeter = 90.0 0.7300 54 3,548 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 10 997 Infiltration: [ 1.00 x 1.064 x 510 x 12.60 x 0.346 / 6] x ® = 2 131 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 13,128 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 18 of 31 ROOM HEATING PEAK LOADS Project Title Date The Sunseri Residence 7/23/2008 Room Information Design Conditions Room Name Master Suite Time of Peak Jan 12 am Floor Area (E)istM Outdoor Dry Bulb Temperature 260F Indoor Dry Bulb Temperature 80 OF Conduction Area U -Value QT OF Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 1 13 514 Infiltration: L 1.001 x 1.064 x 838 x 12.60 x 0.346 16] x &T = 3 501 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 17,015 EnergyPro 4.4 by Energysoft User Number: 3665 Job Number: Page: 19 of 31 838.0 x X x x x x X X x x x x X x X x x X X x x x X x X X X x x X x x x x X X x X X 0.0250 x x x x x x x X X x x x x x x x x x x X x x X x. x x X X X X X X X X X x x X X 54 = = = = = = = = = = = = = = = = = = = = _ = = = = = = = = 1,131 449.3 0.0740 54 1,795 4.5 0.3000 54 73 4.5 0.3000 54 73 4.5 0.3000 54 73 4.5 0.3000 54 73 9.0 0.3000 54 146 30.0 0.3000 54 486 152.3 0.0740 54 609 9.0 0.3000 54 146 45.0 0.5500 54 54 1.,3.36 178.8 0.0740 714 4.5 0.3000 54 73 18.0 0.3000 54 292 9.0 0.3000 54 54 146 583 36.0 0.3000 ...5 _03000 0.3000 5_4 54= 7_3 18.0 292 perimeter = 137.0 0.7300 54 5 401 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 1 13 514 Infiltration: L 1.001 x 1.064 x 838 x 12.60 x 0.346 16] x &T = 3 501 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 17,015 EnergyPro 4.4 by Energysoft User Number: 3665 Job Number: Page: 19 of 31 ROOM HEATING PEAK LOADS Project Title Date The Sunseri Residence 7/23/2008 Room Information Design Conditions Room Name Existing Living 1 Time of Peak Jan 12 am Floor Area 1,498 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 80 OF Conduction Area U -Value AT of Btu/hr R-38 Roof R-19 Wall Milgar_d_V_inyl_(Exd.)_(2616) Milgard Vinyl (Fxd)_2( 650) Milgard Vinyl_(Exd.)_(.6.6.1.6.) Milgard Vinyl (Fxd)_(6650) Milgard Vinyl (Fxd)_(2616) Milgard VinyI (Fxd) 2( 650) Milgard Vinyl_(bcd)_(_4.07.0.) R-19 Wall Milgard Vinyl_(.Exd.)_(.605.0.) Milgard Vinyl (Fxd)_ 6( 016) Milgard Vinyl(Fxd)_ 6( 016) Default Dbl Mtl Tint(Swna)_(6080) R_1.9 -Wall .Milgard_Vinyl_(.F-cd)_(1.61.6.) Milgard Vinyl_(Exd)_(1.61.6) Milgard Vinyl (Fxd)_(1616) Milgard Vinyl (Fxd)_(1616) .Milgard Vinyl_(F-xd.)_(1.61.6.) Milgard Vinyl_(Exd.)_(1.6.1.6.) MilgardVinyI LF x d)1( 616) Milgard Vinyl (Fxd)_(2030) R-19 Wall M i I ga r_d_V_i nyl_(.Exd.)_(.80_1.6) Default Dbl Mtl Tint(SGD)_ 78( 710) Milgard Vinyl (Fxd)_($016) Defa ult_Dbl_Mtl_Tint(S G D.)_(.7.87-1.0.) Milgard Vinyl_(.Fxd)_(_4.070.) Milgard Vinyl_(Exd)_(801.6) Default Dbl Mtl Tint(SGD)_(78710) Slab_On_Grade 1498.0 374.1 3.8 12.5 9.8 32.5 3.8 12.5 28. 264.0 30.0 9.0 9.0 48.0 1,Q3Q9 2.3 -23- 2.3 2.3 2.3 2.3 2.3 6.0 458.0 12.0 60.0 12.0 60.0 --2&0- 12.0 8.0_12. _ 60.0 perimeter = 204.5 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X x X X X X X.54= X x X X X X X X X X X X 54 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 2,022 54 1495 54 62 54 203 54 159 54 526 54 62 54 203 54 454 54 1.055 5_ 54 4.8.6 146 54 146 54 1,996 ,119 54 37 5_4 54 3.7 37 54 37 54 37 3.7 54 37 54 97 54 1830 54 1.9_4 2,495 194 54 2,495 4.54 54 5_4 54 1.9.4 2,495 8,061 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 31903 Infiltration: [ 1.00 x 1.064 x 1=498 X 18.00 X 0.242 / 60] x ® = 6 259 Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 38,162 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 20 of 31 [ROOM HEATING PEAK LOADS Project Title Date The Sunseri Residence 17/23/2008 Room Information Design Conditions Room Name Existing Living 2 Time of Peak Jan 12 am Floor Area 1,057 Outdoor Dry Bulb Temperature 260F Indoor Dry Bulb Temperature 80 OF Conduction Area U -Value QT of Btu/hr 1VI 1 054.8 X- X x X x x x x X x x X x x X x X x x x X x X x x x x x x x x x x x x x x x x 0.0250 X X x x x x x x X x x x x x x5-4 x x X x X X5.4 x X x x x x x x x x x x x x x x x x 54 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 1,424 2.2 1.4700 54 175 558.0 0.0740 54 2,230 972.1 0.0740 54 3,885 21.4 0.7700 54 890 28.0 0.7700 54 1,164 18.0 0.3000 54 292 4.5 0.3000 54 73 18.0 0.3000 54 292 4.5 0.3000 54 73 18.0 0.3000 5-4 54 292 4.5 0.3000 73 351.0 0.0740 54 1,403 18.0 0.3000 54 292 4.5 0.3000 54 7.3 18.0 0.3000 292 4.5 -0.3000 0.0740 5_4 54= 7_3 627.0 2,505 15.0 0.3000 54 243 15.0 0.3000 54 243 15.0 0.3000 54 24.3 146 9.0 0.3000 48.0 0.7700 54 1,996 perimeter =180.5 0.7300 54 7 115 nems snown with an astensK l_I genote conduction through an interior surface to another room. Page Total: I 25,4831 Infiltration: - 1.00 x 1.064 x 1 057 x 12.60 x 0.346 / 60] x 0 = 4 416 Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 29,900 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 21 of 31 [ROOM HEATING PEAK LOADS Project Title Date The Sunseri Residence 7/23/2008 Room Information Design Conditions Room Name Guest Casita Time of Peak Jan 12 am Floor Area 382 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 80 OF Conduction M. Area x x X x x x x x x x x x x x x x x x x x x x X x x x x X x x x x x x X x X x X U -Value x X X x x x x X x x x5_4 x X x X x x X x x x x x x x X X x x x x X x x x x x x X OT of = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr 382.0 0.0250 54 516 306.3 0.0740 54 1,224 143.8 0.0740 54 575 211.9 0.0740 54 847 2.3 0.3000 54 37 2.3 0.3000 54 37 2.3 0.3000 54 37 190.0 0.0740 54 759 15. 0_mo 54 243 20.0 0.7700 54 832 _perimeter = 80.5 0.7300 3,17.3 Items shown with an asterisk (*) denote conduction through an interior surface to another room. Page Total: 8 280 Infiltration: [ 1.00 x 1.064 x 382 x 12.60 x 0.346 / 6] x &T = 1 596 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,876 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 22 of 31 [RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Sunseri Residence 7/23/2008 Room Information Design Conditions Room Name: Master Suite Addition Outdoor Dry Bulb Temperature: 1120F Floor Area: 510 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 72 o Outdoor Daily Range: 340F e burraces 19 Wall Orientation Area X X X X x x X x x x x x U -Factor X X X X x x x x x x x x CLTD 1 (N) 510.0 0.0173 56.0 (N) 261.5 0.0740 23.0 L) 274.0 0.0740 33.0 (� 155.0 0.0740 26.0 4.5X 18.2 (E 0.0x 18.2+ 4.5X 37.8 (E) 0.0X 18.2+ 4.5X 37.8 (E) 0.0x 18.2+ 4.5X 37.8 (S) 0.0 22.9 120.0 22.9 Items shown with an asterisk (') denote conduction through'an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FxdWdw Internal Gain rage I otal Orientation Shaded Area x x x x x X GLF + + + + + + Unshaded Area x X x X X x GLF (N) 0.0x 18.2+ 4.5x 18.2 N 0.0 18.2 4.5 18.2 (� 0.0x 18.2+ 4.5X 18.2 (E 0.0x 18.2+ 4.5X 37.8 (E) 0.0X 18.2+ 4.5X 37.8 (E) 0.0x 18.2+ 4.5X 37.8 (S) 0.0 22.9 120.0 22.9 Page Total Btu/hr 494 445 669 298 P:� 1 906 Btu/hr 82 82 82 170 170 170 2.754 3,5111 Btu/hr Occupants Occupants x 230 Btuh/occ. = 460 Dwelling Units x 1,600 Btuh = 1.60 Infiltration: 1.064 x 0.92 x 35.99 x = 1407 Air Sensible CFM ELA TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,8841 Latent Gain Btu/hr Occupants 0 Occupants x 200 Btuh/occ. = 400 Infiltration: 4,771 x 0.92 x 35.99 x 0.00454 = 716 Air Latent CFM ELA QW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,116 2 Equipment 1 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 23 of 31 [RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Sunseri Residence 7/23/2008 Room information Desicin Conditions Room Name: Master Suite (Existing) Outdoor Dry Bulb Temperature: 1120F Floor Area: 838 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F ue Surfaces 19 Wall I:ail Orientation Area X X X X X x x X X x x x U -Factor X X X X X x x x X X x x CLTD 1 = = = = = = = = = = U 838.0 0.0173 56.0 U 449.3 0.0740 23.0 (� 152.3 0.0740 26.0 U 178.8 0.0740 33.0 (N) 0.0x 18.2+ 4.5x 18.2= 82 (N) 0.0x 18.2+ 4.5x 18.2= 82 (N) 0.0x 18.2+ 9.0X 18.2= 164 N 0.0x 18.2+ 30.0X 18.2= 547 (S) 0.0x 18.2+ 9.0x 18.3= 165 a) 0.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FxdWdw 3( 016) FxdWdw 3( 016) FxdWdw3( 016) FxdWdw3( 016) FxdWdw(6016) FxdWdw @050j_ FxdWdw(6016) SGD59( 710)_ FxdWdw (3016) FxdWdw (3060) Internal Gain Occupants 2 Equipment rage I otal Btu/hr 812 765 293 437 2 306 Orientation Shaded Area x x X GLF + + + Unshaded Area X X X GLF = = = Btu/hr (N) 0.0x 18.2+ 4.5x 18.2= 82 U 0.0x 18.2+ 44.5X 18.2= 82 (N) 0.0x 18.2+ 4.5x 18.2= 82 (N) 0.0x 18.2+ 4.5x 18.2= 82 (N) 0.0x 18.2+ 9.0X 18.2= 164 N 0.0x 18.2+ 30.0X 18.2= 547 (S) 0.0x 18.2+ 9.0x 18.3= 165 a) 0.0 22.9 45.0 22.9 1,033 U 0.0 18.2 4.5 37.8 170 (W) 0.0x 18.2+ 18.0X 37.8= 681 Page Total 3,0891 Btu/hr B1Occupants x 230 Btuh/occ. _ 460 Dwelling Units x 1,6001 Btuh 1 600 Infiltration: 1.064 x 0.92 x 59.13 x �- 4 , = 2 312 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,3211 Latent Gain Btu/hr Occupants F 21 Occupants x 200 Btuh/occ. = 400 Infiltration: 4,771 x 0.92 x 59.13 x 0.00454 = 1177 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,577 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 24 of 31 [RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Sunseri Residence 7/23/2008 Room Information Desian Conditions Room Name: Master Suite (Existing) Outdoor Dry Bulb Temperature: 1120F Floor Area: 838 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain rage I otal Orientation x x x x x x x x x x x x X x X x x x x x x x x x x x x x x x x x + + + + + + + + Unshaded Area X x x X X x x x Page GLF = — = = = = = = Btu/hr (W) 0.0x 18.2+ 9.0x 37.8= 341 (W 0.0 18.2 36.0 37.8 1 362 (W 0.0x 18.2+ 4.5X 37.8= 170 (W� 0.0x 18.2+ 18.0X 37.8= 681 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain rage I otal Orientation Shaded Area X x X x x x x x GLF + + + + + + + + Unshaded Area X x x X X x x x Page GLF = — = = = = = = Btu/hr (W) 0.0x 18.2+ 9.0x 37.8= 341 (W 0.0 18.2 36.0 37.8 1 362 (W 0.0x 18.2+ 4.5X 37.8= 170 (W� 0.0x 18.2+ 18.0X 37.8= 681 2 554 Total Btu/hr Occupants 2 Occupants X 230 Btuh/oCC. = 460 Equipment 1 Dwelling Units X 1,6001 Btuh 1,6001 Infiltration: 1.064 x 0.92 x 59.13 x40 = 2312 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,3211 Latent Gain ` Btu/hr Occupants 0 Occupants x 200 Btuh/occ. = 400 Infiltration: 4,771 x 0.92 x 59.13 x 0.00454 = 1177 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,577 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 25 of 31 LRESIDENTIAL ROOM .COOLING' LOAD SUMMARY, Project Title Date The Sunseri Residence 7/23/2008 Room Information Desian Conditions ' Room Name: Existing Living 1 Outdoor Dry Bulb Temperature:112°F Floor Area: 1,498 sf Outdoor Web Bulb Temperature: *- '78°F Indoor Dry Bulb Temperature: 72 OF Outdoor Daily Range: 340F Opaque Surfaces Orientation , Area U -Factor CLTD 1 - Btu/hr (N) 1,498.0 X 0.0173 X 56.0 = 1,451 (N 374.1 X 0.0740 X 23.0 = 637 (� 264.0 X : 0.0740 X 33.0 = 645 U 1,030.9 , X 0.0740 X 26.0 = 1,983 (W) 458.0 X 0.0740 X 33.0 = 1,118 1 g 5 834 Items shown with an asterisk (') denote conduction through an interior surface to another room. Pa a Total 1. Cooling Load Temperature Difference (CLTD) , Shaded Unshaded Fenestration Orientation 4: • Area GLF - ` Area GLF Btu/hr FxdWdw (2616) FxdWdw(2650) FxdWdw(6616) FxdWdw (6650) FxdWdw(2616) FxdWdw(2650) FxdWdw (4070) FxdWdw (6050) FxdWdw (6016) FxdWdw(6016) • Page_Total 2 753 Internal Gain ' Btu/fir Occupants B2. Occupants x 230 Btuh/occ. _ i. 460 Equipment 1 Dwelling Units x 1 600 Btuh a =. 1 600 Infiltration: 1.064 x 0.92 x 105.70 x i.4 = 4132 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24 876 , ' Latent Gain' Btu/lir ` Occupants IF 21 Occupants X I Btuh/occ. I = - 4001, Infiltration: 4,771 x 0.92 x 105.70 x 0.00454 = 2103 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,503 EnergyPro 4.4 by Energysoft User Number: 3665 Job Number: Page: 26 of 31 •(N x, (N) x X x x x x X, - X X. x x x X X + l + + _ _ = = =I = - ` , 41 A = = = r. 69 ' (N 0.0x 18.2+ 12.5X 18.2= 228 (� 0.0x 18.2+•p. 9.8x 18.2= t° (rte 0.0 18.2 32.5 18.2 593 (N 0.0X 18.2+ 3.8X 18.2= 69 (N) 0.0x : 1 g 5 834 Items shown with an asterisk (') denote conduction through an interior surface to another room. Pa a Total 1. Cooling Load Temperature Difference (CLTD) , Shaded Unshaded Fenestration Orientation 4: • Area GLF - ` Area GLF Btu/hr FxdWdw (2616) FxdWdw(2650) FxdWdw(6616) FxdWdw (6650) FxdWdw(2616) FxdWdw(2650) FxdWdw (4070) FxdWdw (6050) FxdWdw (6016) FxdWdw(6016) • Page_Total 2 753 Internal Gain ' Btu/fir Occupants B2. Occupants x 230 Btuh/occ. _ i. 460 Equipment 1 Dwelling Units x 1 600 Btuh a =. 1 600 Infiltration: 1.064 x 0.92 x 105.70 x i.4 = 4132 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24 876 , ' Latent Gain' Btu/lir ` Occupants IF 21 Occupants X I Btuh/occ. I = - 4001, Infiltration: 4,771 x 0.92 x 105.70 x 0.00454 = 2103 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,503 EnergyPro 4.4 by Energysoft User Number: 3665 Job Number: Page: 26 of 31 •(N x, (N) 0.0x X x x 18.2+ + l + + 3.8x X x x 18.2= = = = r. 69 ' (N 0.0x 18.2+ 12.5X 18.2= 228 (� 0.0x 18.2+•p. 9.8x 18.2= 179 (rte 0.0 18.2 32.5 18.2 593 (N 0.0X 18.2+ 3.8X 18.2= 69 (N) 0.0x 18.2+ 12.5X .18.2= 18.2= 228 0.0X 18.2+ «.28.0X 0.0x 511 (E 30.0X 18.2+ 37.8= 547 (E) 9.0 .18.2 0.0 37.8' "":164 (� 9.0x 18.2+ 0.0x x,37.8= 164 [RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Sunseri Residence 7/23/2008 Room Information Design Conditions Room Name: Existing Living 1 Outdoor Dry Bulb Temperature: 1129F Floor Area: 1,498 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F updque aunat;es e Orientation Area U -Factor CLTD 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 61 1 rage I Dial Orientation X X x x x X x X x X x X X x X x X X x x X X X X X X x X X x X + + + + + +0.0 + Unshaded Area X X X X X X x GLF (E) 47.4 37.3 0.6 72.3 (S 0.0 18.2 2.3 18.3 (S) -6.0X 18.2+ 2.3x 18.3 (S) 0.0x 18.2+ 2.3X 18.3 (S) 0.0X 18.2+ 2.3X 18.3 U 0.0 18.2 2.3 18.3 (S) 0.0 18.2 2.3 18.3 (S 0.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 61 1 rage I Dial Orientation Shaded Area X x X x X X x GLF + + + + + +0.0 + Unshaded Area X X X X X X x GLF (E) 47.4 37.3 0.6 72.3 (S 0.0 18.2 2.3 18.3 (S) -6.0X 18.2+ 2.3x 18.3 (S) 0.0x 18.2+ 2.3X 18.3 (S) 0.0X 18.2+ 2.3X 18.3 U 0.0 18.2 2.3 18.3 (S) 0.0 18.2 2.3 18.3 (S 0.0 18.2 2.3 18.3 (S) 0.0x 18.2+ 6.0X 18. 0N) 12.0 18.2 37.8 Page Total Btu/hr 1 Btu/hr Internal Gain Btu/hr Occupants 1:11 Occupants x 230 Btuh/occ. _ 460 Equipment Dwelling Units x 1,6001 Btuh 1 600 Infiltration: 1.064 X 0.92 X 105.70 X �40 = 4132 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,876 Latent Gain Btu/hr Occupants F 21 Occupants x 200 Btuh/occ. = 400 Infiltration: 4,771 x 0.92 x 105.70 x 0.00454 = 2103 Air Latent CFM ELA QW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,503 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 27 of 31 I [RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Sunseri Residence 17/23/2008 Room Information Design Conditions Room Name: Existing Living 1 Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,498 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F surfaces Orientation Area U -Factor CLTD 1 Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 1 1 Page Total L 01 Orientation X x x x x x x x x x x + + + + + + + + + = x x x x x x x x x GLF = = = = = = = = x U x 37.3 = 72.3 2,238 (W x 18.2+ x 37.8= = (M 60.0 37.3 x 72.3 x (W) = 18.2 0.0 37.8 x U x 18.2+ = 37.8= 219 W x 37.3 x 72.3 = x x = x x = x x = " x x = x x = x x = Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 1 1 Page Total L 01 Orientation Shaded Area x x x x x x x x x GLF + + + + + + + + + Unshaded Area x x x x x x x x x GLF = = = = = = = = Btu/hr U 60.0 37.3 0.0 72.3 2,238 (W 12.0x 18.2+ 0.0x 37.8= 219 (M 60.0 37.3 0.0 72.3 2,238 (W) 28.0 18.2 0.0 37.8 511 U 12.0x 18.2+ 0.0x 37.8= 219 W 60.0 37.3 0.0 72.3 2,238 Internal Gain Occupants 2 Occupants x 230 Btuh/occ. _ Equipment 1 Dwelling Units x 1,6001 Btuh = Page Total 1 7,6621 Btu/hr 460 1,6001 Infiltration: 1.064 x 0.92 x 105.70 x 4132 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,8761 Latent Gain Occupants 0 Occupants x 200 Btuh/occ. _ Btu/hr 400 Infiltration: 4,771 x 0.92 x F 105.70 x 0.00454 = 2103 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,503 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 28 of 31 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Sunseri Residence 7/23/2008 Room Information Desi n Conditions Room Name: Existing Living 2 Outdoor Dry Bulb Temperature: 1120F Floor Area:. 1,057 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr R-19 Wall R-19 Wall R-19 Wall (NN) 1,054.8 x x x x x x x x x x x x 0.0173 x x x x x x x x x x x. x 56.0 (N 558.0 0.0740 23.0 (E) 972.1 0.0740 33.0 L) 351.0 0.0740 26.0 (W 627.0 0.0740 33.0 1 548 E 0.0 37.3 28.0 72.3 2,025 E 0.0x 18.2+ 18.0X 37.8= 681 (E) 0.0X 18.2+ 4.5x 37.8= 170 (E 0.0x 18.2+ 18.0X 37.8= 681 U 0.0x 18.2+ Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference.(CLTD) Fenestration a Page Total 1,022 950 = 2,374 675 1,531 6 552 Orientation Shaded Area x x x x x x GLF + + + + + + Unshaded Area x x x x x x GLF = = = = = = Btu/hr (Sky) 0.0 58.5 2.2 161.4 355 (E) 0.0 37.3 21.4 72.3 1 548 E 0.0 37.3 28.0 72.3 2,025 E 0.0x 18.2+ 18.0X 37.8= 681 (E) 0.0X 18.2+ 4.5x 37.8= 170 (E 0.0x 18.2+ 18.0X 37.8= 681 U 0.0x 18.2+ 4.5x 37.8= 170 (E) 0.0x 18.2+ 18.0X 37.8= 681 (E) 0.0 18.2 4.5 37.8 170 (S) 0.0 18.2 18.0 18.3 330 Page Total i 6,812 Internal Gain -Btu/hr Occupants B2 Occupants x 230 Btuh/oCC. _ 460 Equipment 1 Dwelling Units x 01 Btuh 1 600 Infiltration: 1.064 x 0.92 x 74.58 x 40 = 2 916 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,5121 Latent Gain Occupants 0 Occupants x 200 Btuh/oCC. _ Btu/hr 400 Infiltration: 4,771 x 0.92 x 74.58 x 0.00454 = 1484 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,884 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 29 of 31 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Sunseri Residence 7/23/2008 Room Information Design Conditions Room Name: Existing Living 2 Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,057 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F e surtaces . Orientation Area U -Factor CLTD 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Nage I otal Orientation X x x x x x x x x x x x x x X x x X x x x x x x x x x x x x + + + + + + Unshaded Area x x X x X Ix GLF S 0.0 18.2 4.5 18.3 (S 0.0X 18.2+ 18.0X 18.3 (S) 0.0 18.2 4.5 18.3 (W 0.0X 18.2+ 15.0x 37.8 (W 0.0x 18.2+ 15.0X 37.8 (W 0.0x 18.2+ 15.0X 37.8 (M 9.0x 18.2+ 0.0x 37.8 (W 47.4 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Nage I otal Orientation Shaded Area x x X x x X GLF + + + + + + Unshaded Area x x X x X Ix GLF S 0.0 18.2 4.5 18.3 (S 0.0X 18.2+ 18.0X 18.3 (S) 0.0 18.2 4.5 18.3 (W 0.0X 18.2+ 15.0x 37.8 (W 0.0x 18.2+ 15.0X 37.8 (W 0.0x 18.2+ 15.0X 37.8 (M 9.0x 18.2+ 0.0x 37.8 (W 47.4 37.3 0.6 72.3 Page Total Btu/hr 0 Btu/hr Internal Gain Btu/hr Occupants 1:11 Occupants X 230 Btuh/oCC. _ 460 Equipment Dwelling Units x 1,600 Btuh 1 600 Infiltration: 1.064 x 0.92 x 74.58 x 40 = 2 916 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,5121 Latent Gain Btu/hr Occupants 0 Occupants X 200 Btuh/oCC. = 400 Infiltration: 4,771 x 0.92 x 74.58 x 0.00454 = 1484 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,8 4 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 30 of 31 r RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Sunseri Residence 17/23/2008 Room Information Desicin Conditions Room Name: Guest Casita Outdoor Dry Bulb Temperature: 1120F Floor Area: 382 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr R-38 Roof R-19 Wall R-19 Wall 9 Wall U 382.0 X X X X X x x x x x x x 0.0173 X X X X X x x X x x x x 56.0 (N 306.3 0.0740 23.0 (� 143.8 0.0740 33.0 (� 211.9 0.0740 26.0 (YJV 190.0 0.0740 33.0 42 (U 0.0x 18.2+ -2.3 2.3X 18.3= 42 U 0.0x 18.2+ 15.0X 37.8= 568 U 0.0 37.3 20.0 72.3 1.446 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Occupants 2 Equipment 1 rage I otal 370 521 351 408 464 2,1141 Orientation 26.95 x Shaded Area X x x x x X X GLF + + + + + + + Unshaded Area X x x x x X x x GLF = = = - = c c Btu/hr S 0.0x 18.2+ 2.3x 18.3= 42 U 0.0x 18.2+ 400 18.3= 42 (U 0.0x 18.2+ -2.3 2.3X 18.3= 42 U 0.0x 18.2+ 15.0X 37.8= 568 U 0.0 37.3 20.0 72.3 1.446 Page Total 2140 Btu/hr Occupants x 230 Btuh/occ. = 460 Dwelling Units x 1,6001 Btuh 1,6001 Infiltration: 1.064 x 0.92 x 26.95 x = F771054 Air Sensible CFM ELA .OT TOTAL HOURLY SENSIBLE. HEAT GAIN FOR ROOM 7368 Latent Gain Btu/hr Occupants 0 Occupants x 200 Btuh/oCC. = 400 Infiltration: 4,771 x 0.92 x 26.95 x 1 0.00454 = 536 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 936 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page: 31 of 31