12-0873 (RER)I . I . . 4'Q
4a` :(!F I •
P.O' BC�"� X04 �� VOICE 760 777.-7012
78-495 CALLE TAMPICO oFAX (76 0) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Application Number:
Property Address:
.APN:
Application description:
Property Zoning:
Application valuation:
Applicant:
12-00000873 -
78631 TALKING ROCK TURN
770-300-029- - -
REMODEL - RESIDENTIAL
LOW DENSITY RESIDENTIAL
85000
Architect or Engineer:
�V
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commenc g i -
Section 70 0) of Division 3 of the Busin ss and Professionals Cod , nd my License is in full forc n f
License I ss. B Licen 1 815648 l
4 Date. 2 Contractor. a, Y-1 p—f re L�.. /1
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License for the ,
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit oto
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole compensation, willdo the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. - If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects With a contractor(s) licensed
pursuant to the Contractors' State License LawJ.
1 1 I am exempt under Sec. BAP.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued ISec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
Date: 4/24/13
Owner:
DOUGLAS.& LYNN BRENGEL
TRUST
920 AVONDALE RD.
SAN MARINO, CA 91108
De
Contractor:
('
APR
(�
ENGSTROM CONSTR MANAGEM
77455 EVENING STAR ,
INDIAN WELLS, CA 92210
CITY
F LLA
rt pEPTTA
(760)668-3961
NANC
Lic.. No.: 835648
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are: -
Carrier STATE FUND 09 O1 1®olicy Number, 9022651
I certify that, in the perform ce of a work for which this permit is issued, I shall not employ any
YLURETI"O
in any manner so s to ome ject t e workers' compensation laws of California,
ree that, if I sho d bec e e t orkers' compensation provisions of Section
oof the Labor C s f r o pl with those provisions.
Date: 1pplicant:
WARNI GSECURE WOR SATION COV AGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND C S UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT -
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to anypermit issued as a result of this application,
the owner, and the applicant, each -agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit. '
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work.for 180 days will subject
permit to cancellation. -
I certify tha I have read this application and state that the ov informatio i corr ct: I agree to comply with all
city and co ty-or finances and state laws relating to b ' g ns a h by authorize representatives
of thi u t%y to ter upon the above-mentione r er f , p ioo 0
Date: C. gnature (Applicant or Agen `
Application, Number•
12=00000873
------ Structure Information
EXIST 6384 SF SFD
Other struct info . .
CODE EDITION 2010
Permit.. . •BUILDING
PERMIT
Additional desc .
Permit Fee
572.00 Plan Check Fee
371.80
Issue Date
Valuation
85000
Expiration Date_
10/21/13
Qty Unit Charge
-Per
Extension
BASE FEE
414.50
4.5000
THOU BLDG 50,001-100,000
15,7.50
Permit
ELECT - ADD/ALT/REM
Additional desc
20
Permit Fee
41.25 Plan. Check Fee-.
10.31
` Issue Date
Valuation . . . '.
0
Expiration Date
10/21/13
Qty Unit Charge
Per
Extension._
BASE FEE
15.00'
20.00 .7500
PER ELEC DEVICE/FIXTURE 1ST 20
15.00
25.00 .4500
EA ELEC DEVICE/FIXTURE 520
11.25
Permit MECHANICAL
Additional desc •.
-Permit Fee.
43.50• Plan Check Fee '.
10.88 .
Issue Date
Valuation . . . .
0.
Expiration Date
10/21/13
Qty Unit Charge
Per
Extension
BASE FEE,
15.00
2.00 4.5000
EA MECH VENT INST/ DUCT ALT
9.00
3.00 6.5000
EA MECH VENT FAN
-----------------------------------------
•,
19.50-------------------------------
Permit,..PLUMBING
Additional desc'.
Permit Fee
69.00 Plan Check Fee':
17.25.
Issue Date
Valuation . . . .
0
Expiration,Date
10/21/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
LQPERMIT ' ..
LQPERMIT
'"P✓`r Application Number . . . . 12700000873
Permit . . . . . . PLUMBING
Qty Unit Charge Per
Extension
7.00 6.0000 EA PLB FIXTURE
42.00
1.00 3.0000 EA PLB WATER.INST/ALT/REP
3.00
3.00 3.0000 EA PLB FIXTURE DRAIN/VENT REP/ALT
9.00
---------------
Special Notes and Comments
_
REMODEL EXISTING MASTER BATH AREA,
POWDER ROOM AND ADD 3 SKYLIGHTS PER
ENGINEERED DESIGN. 2010 CODES. ENGINEER
OF RECORD: CHARLES GARLAND C11991.
-------------=---------------------------------------------------------------
Other Fees . . . . . . BLDG STDS ADMIN (SB1473)
4.00
ENERGY REVIEW FEE
37.18
STRONG MOTION (SMI) "- RES
8.50
Fee summary'. Charged Paid Credited
Due
Permit Fee Total 7.25.75 .00 .00
725.75
Plan Check Total 410.24. .00 .00
410.24
Other Fee Total 49.68 .00 .0.0
49.68
Grand Total 1185.67 .00 .00.
1185.67
LQPERMIT
$b i boc,v, ujua
Bin.# ..
CI�y. of La Quinta
ButWing st Safety Dh&ori -
Permit #
P.Q. Box 1504,78-495 Calle Tampico
L4.Quinta, CA 92253•- (760) 7777012
Building Permit•Application'and Tracking Sheet
Project Address:7 6 -6 %3 l
p, L;LI iJ & er's Name:. Gi
A. P. Number. �.'7i .-
.— ®� Address:.. VLt �{ CD `TU
Legal Description:
City, ST, Zip: AJ (� C
Contractor.
Telephone &✓ N .x •.: ry
Address:
Project Description:
City, ST, Zip:
Telephone:
P
°t �.ME
MEN tt<• ;� fGV1 (—��.rl
State Lic. # :
City Lic. M.
Arch, Engr.,lDesigner. LSA
G� ' ✓ 1 i+� E� ' t;�� .
Address:
City., ST, Zip: i CqX- . dt77_'Zj bo.
Telephone: '74to 4'Z4-e0113l5T_ .1 Construction Type:. Occupancy:
State Lic. #:
.�w7u Project
� ct type (circle one): New Add'n Alter Repair Demo
't.
Name of Contact Person: 7611" 2"1 ��Jj?f� Sq. FL: # Stories: #Units:
Telephone '# of Contact Person:
. aokii>o1.1 T'-161VA Estimated Value of Project: ' i!S�j , cCd a
APPLICANT: DO NOT WRITE BELOW THIS UNE
# Submittal Req'd Recd TRACKYNG PERMIT FEES
Plan Sets
Plan Check submitted` -
I Amoaat
Structural Cafes.
Reviewed, ready for corrections Plan Check Deposit. .
Truss C21cs•
Called Contact Person 11 Plan Check Balance.
Title 24 Calm
Pians picked up (� ' Constractloa
Flood plain plan
Plans resubmitted —Mechanical
Grading plan
rd Review, ready for corrections ue Electrical
Sobcontflctor List
Called Contact Person ( I Plumbing /
Grant Deed
Plans picked up S.M.L
H.O.A. Approval
Plans resubmitted Grading
IN ROUSE:-
7id Review, ready for correctionsfissue Developer Impact Fee
Planning Approval
Called Contact Person A.LP.P.
Pub. Wks. Appr '
Date of permit issue
School Fees
Total Permit Fees 5
August 7, 2012
Mr. and Mrs. Brengle
78631 Talking Rock Turn
La Quinta, CA 92253
RE: Brengle/Lot 46 Tract 28470-2 at 78631 Talking Rock Turn
Architectural Remodel
Dear Mr. and Mrs. Brengle:
The Tradition Architectural Design Review Committee (ADRC) reviewed and approved the
proposal for Remodel at your home on Talking Rock Turn. The project is approved and can start
construction subject to the following stipulations:
1. All exterior lighting, color and materials to match existing.
2. A revised landscape plan should be submitted for consideration.
3. The project is anticipated to be under construction for approximately three months.
Your (Remodel) Design Review Fee and Application were not included with this submittal and
are due to the Association. Additionally, plans were submitted via PDF but a hard copy is
required for our files. As a reminder, plans are due the last Thursday of each month by 4:30 p.m.
at the Desert Resort Management offices in Palm Desert. Please contact Brook Marshall at (760)
219-8057 or by email at B ..rr.cotn with any questions or to schedule a Pre Construction
Meeting at the lot (once your BLI11dino Permit has been obtained and prior to the commencement
of construction).
Sincerely,
Tradition Architectural Design Reviefv Committee
cc: Gordon Stein
Glenn Engstrom
ADRC File
DESERT RESORT MANAGEMENT
POST OFFICE Bax 14387 • PALM DESERT, CALIFORNIA 92255-4387
42.635 MELANIE PLACE, SUITE 103 • PALM DESERT, CALIFORNIA 92211
TELEPHONE (760) 346-1161 • FAx (760) 346-9918
ESR=2253
E'REPORTTM
Reissued July 1, 2008
This report is subject to re-examination in one year.
ICC Evaluation Service, Inc. Business/Regional Office ■ 5360 Workman Mill Road, Whittier, California 90601 ■ (562) 699-0543
Regional Office ■ 900 Montclair Road, Suite A, Birmingham, Alabama 35213 ■ (205) 599-9800
W W W.I CC-eS.ora Regional Office ■ 4051 West Flossmoor Road, Country Club Hills, Illinois 60478 ■ (708) 799-2305
DIVISION: 08—DOORS AND WINDOWS `r_ 3.. Domes for the 21 -inch diameter model
Section: 08620—Unit Skylights �(/ a�� O�Q� °(So Master/330D$):
p� The 2 -inch-diameter (533 mm) model is available with single
REPORT HOLDER:! �P�� G® acrylic. ee Figure 2 and Table 1.
SOLATUBE INTERNATIONA I`� O 0%11 O� vG�N 3.3 DD a Rings.
2210 OAK RIDGE WAY �j Q� s'��` D tfi ngs are used to connect the reflective tubing to the
VISTA, CALIFORNIA 92081-834J1� QQOng and secure the dome. A reflector may be mounted
(760) 597-4400 PoQ,� �� inside the dome. Domes snap onto the dome ring for the 10-
www.solatube.com inch- and 14 -inch -diameter (254 and 356 mm) models. Domes
info@solatube.com ��� are mechanically fastened to the dome ring for the 21 -inch -
diameter (533 mm) model. See Figures 1 and 2.
EVALUATION SUBJECT: 3.4 Ceiling Rings:
FKY
ATUBE TUBULAR DAYLIGHT_DEVICE (TDD)LIGHTS)
1.0 EVALUATION SCOPE
Compliance with the following codes:
2006 International Building Code® Q,gv�D
2006 International Reside lo. ,
Properties evaluated:
. Structural SEP 0 7 2012.
■ Durability
■ Weather resistance
2.0 USES°
The Solatube Tubular Daylight Devices described in this
report are plastic -glazed tubular skylights complying with
Chapters 24 and 26 of the IBC and UBC, and Section R308.6
of the IRC.
3.0 DESCRIPTION
Solatube TDD skylights consist of a light -transmitting dome
with an optional internal curved reflector; a roof -mounted
support base (flashing or curb); an upper -tube -supporting
element (dome ring); reflective light -conducting tubing of either
adjustable 0 -to -30 -degree elbows or 0 -to -90 degree elbows,
and/or straight tube extensions; a bottom -tube -supporting
element (either ceiling ring or round -to -square plastic
transition box); and a ceiling -mounted light -diffusing assembly
(diffuser). The Solatube skylights have a maximum allowable
air leakage of 0.3 cfm/ft2 (1.5 Us • m2). Solatube TDD
skylights are available in 10-, 14- and 21 -inch -diameter (254,
356 and 533 mm) sizes, identified as models 160 DS, 290 DS
and SolaMaster/330DS, respectively. See Figures 1 and 2.
3.1 Domes for the 10- and 14 -inch -diameter models (160
DS and 290 DS):
The 10- and 14 -inch -diameter (254 or 356 mm) models are
available with single acrylic and dual -glazed acrylic options.
See Figure 1 and Table 1.
Ceiling rings are used as mounting frames for the diffuser
assemblies and to connect the light -conducting tubing to the
tube -supporting ceiling for the 10- and 14 -inch -diameter (254
or 356 mm) models. See Figure 1.
3.5 Round -to -square Transitions:
Round -to -square transitions are used to connect cylindrical
tubing to a square aperture at the ceiling for suspended and
framed ceiling applications forthe 21 -inch -diameter (533 mm)
model. See Figure 2.
3.6 Flashing:
Pitched flashing is used for the 10- and 14 -inch -diameter (254
or 356 mm) models. Nonpitched flashing or curb flashing is
used with the 10-, 14- and 21 -inch -diameter (254, 356 or 533
mm) models. Counter -flashing is used for the 10- and 14 -inch -
diameter (254 or 356 mm) models in tile roof applications.
Turret extensions are available in lengths of 2, 4, 12, 24, 36
and 48 inches (51, 102, 305, 610, 914 and 1219 mm) for the
10- and 14 -inch -diameter (254 and 356 mm) models, and 12,
24, 36 and 48 inches (305, 610, 914 and 1219 mm) for the 21 -
inch -diameter (533 mm) model. See Figures 1 and 2.
3.7 Diffusers:
The Optiview diffuser is a Class A polycarbonate material with
a flame spread index not exceeding 25 and a smoke developed
index not exceeding 450, when tested in accordance with
ASTM E 84. Vusion lens and optional decorative diffuser
attachments are Class C (Class III) acrylic materials with a
flame spread index not exceeding 200 and a smoke developed
index not exceeding 450, when tested in accordance with
ASTM E 84. See Figures 1 and 2 and Table 1.
4.0 INSTALLATION
4.1 General:
Installation of the TDD skylights must comply with this report,
the applicable code and the manufacturer's published
installation instructions. See Figures 1 and 2 for details.
A 10.75-, 14.75- or 22 -inch -diameter (273, 375 or 559 mm)
round hole, for the 10-, 14- and 21 -inch -diameter (254, 356 or
REPORTS" are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an
endorsement ofthe subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, Inc., express or implied, as to anyfinding
or other matter in this report, or as to any product covered by the report.
Copyright @ 2008
FUMM �ovm
wmouci aAr:rami
Page 1 of 5
r -
Page 2 of 5 ESR -2253
533 mm) skylights, respectively, must be cut in the roof
sheathing and ceiling below the attic space. The sheathing
must be minimum 5/,_inch-thick plywood complying with DOC
PS 1 or DOC PS 2 or minimum 0.030 -inch -thick steel deck
having a minimum tensile strength of 45000 psi. The skylight
support base must be attached to the plywood roof sheathing
using eight No. 10 by 2 -inch -long (51 mm) stainless steel or
dacrotized-finish (corrosion -resistant) steel sheet metal screws
for the 10- and 14 -inch -diameter (254 and 356 mm) models,
and sixteen screws for the 21 -inch -diameter (533 mm) model.
The skylights are attached to metal roof decks with minimum
No. 10 Teks screws, using the same number of fasteners as
for wood decks. A felt or foam weather seal must be adhered
to the top edge of the skylight support base for the 21 -inch -
diameter (533 mm) model. A polyurethane -based sealant
must be used to seal the flashing or curb to the roof.
The reflective top tube with attached dome ring must be
inserted into the skylight support base opening: A curved
reflector may be mounted inside the dome. The dome ring
must be secured to the support base using four No. 8 by 1 -
inch -long (25.4 mm) stainless steel, dacrotized-finish
(corrosion -resistant) or other corrosion -resistant steel pan or
truss head sheet metal screws for the 10- and 14 -inch -
diameter (254 and 356 mm) units, and six No. 8 by '/4-inch-
long
/;inch-
long (19.1 mm) screws for the 21 -inch -diameter (533 mm)
unit. The 10- and 14 -inch -diameter (254 and 356 mm) units
terminate at the ceiling into the ceiling ring installed using six
No. 6 by 15/, -inch -long (41 mm), corrosion -resistant, bugle
head, drywall screws and/or four plastic self-locking anchors
with No. 8 by 1'/, -inch -long (38 mm), corrosion -resistant sheet
metal screws or four plastic anchors/screws only. The 21 -inch
(533 mm) unit terminates at the ceiling into a round -to -square
plastic transition box set into the framework on a suspended
T -bar ceiling system, or must be installed into a gypsum
ceiling using four No. 6 by 15/8 inch -long (41 mm), corrosion -
resistant, bugle head drywall screws. The 10- and 14 -inch -
diameter (254 and 356 mm) light diffusers must be secured
onto the ceiling ring by means of the Snap fit feature. The 21 -
inch -diameter (533 mm) light diffuser must be secured onto
the square -to -round plastic transition box by means of four
diffuser latches or, for the 21 -inch -diameter (533 mm) open
ceiling light diffuser, by means of the snap -in features.
The lowest edge of the support base turret opening must be
at least 4 inches (102 mm) above the plane of the roof. This
may be accomplished with installation of the optional Solatube
2- or 4 -inch -high (51 or 102 mm) galvanized or aluminized -
steel turret extension. The 4 -inch (102 mm) clearance
requirement and the turret extension are not required on roofs
of IBC Group R-3 occupancy with a minimum slope of 3:12
(25%).
4.2 Tile Roofs:
For installation on a tile roof, a "dead -soft" 0.020 -inch -thick
(0.51 mm) pleated aluminum sheet must be used as malleable
counter -flashing. After the appropriately sized hole for the 10 -
or 14 -inch -diameter (254 and 356 mm) Solatube skylight is cut
in the roof sheathing, a metal base flashing must be placed
over the hole and secured in place using eight No. 10 by 2 -
inch -long (51 mm) stainless steel or dacrotized-finish steel
panhead sheet metal screws. See Figure 1 for additional
details. Tiles surrounding the flashing are cut according to the
profile of the flashing, with a maximum clearance of V, inch
(12.7 mm) from the flashing. The pleated aluminum sheet,
with a circular hole cut in the center to match the flashing,
must be placed over the flashing. A galvanized or aluminized
steel turret extension ring must be placed over the opening of
the base flashing, sandwiching the aluminum sheet between
the flashing and turret extension ring. The aluminum sheet
must then be secured to the top of the tiles in the course
below using nonalkaline and nonacidic tile mastic. The
remaining sheet must be tucked under the tiles in the upper
course.
When installing the system with high-profile tiles, the upper
and side edges of the pleated aluminum must be bent up to
form a "bird stop" and water seal under the upper course tiles
and surrounding field tiles.
4.3 Allowable Loads:
Under the IBC and IRC, the allowable inward (positive) and
outward (negative) loads are 70 psf (3.33 kPa) in both
directions for the 21 -inch model and 70 psf (3.33 kPa) and 60
psf (2.87 kPa), respectively for both the 10- and 14 -inch
models.
5.0 CONDITIONS OF USE
The Solatube Tubular Daylight Devices described in this
report comply with, or are suitable alternatives to what is
specified in, those codes listed in Section 1.0 of this report,
subject to the following conditions:
5.1 Installation must comply with this report, the
manufacturer's published installation instructions and
IBC Section 2405 and, IRC Section R308.6 as
applicable. In the event of a conflict between the
manufacturer's published installation instructions and
this report, this report governs.
5.2 The maximum positive and negative allowable loads are
as described in Section 4.3 of this report.
5.3 Where a Class A, B or C roof covering is required,
skylight dome edges for the 10- and 14 -inch -diameter
(254 and 356 mm) skylights must be protected with the
application of galvanized or aluminized steel dome -edge
protective rings, as shown in Figure 1. Dome -edge
protective rings are not required for the 21 -inch -diameter
(533 mm) skylights with 8- or 11 -inch -high (203 or 279
mm) flashing, or any model with curb -mount flashing on
curbs a minimum of 8 inches (203 mm) high.
5.4 Solatube TDD skylights are produced in Vista, California,
under a quality control program with inspections by
Underwriters Laboratories Inc. (AA -668).
6.0 EVIDENCE SUBMITTED
Data in accordance with the ICC -ES Acceptance Criteria for
Plastic Skylights (AC 16), dated February 2008.
7.0 IDENTIFICATION
The Solatube Tubular Daylight Devices described in this
report must have a permanent label bearing the
manufacturer's name (Solatube) and address; the product
name; the name of the inspection agency (Underwriters
Laboratories Inc.); the evaluation report number (ESR -2253);
the plastic classification (CC -1 or CC -2); the thickness of the
plastic glazing prior to forming. The 21 -inch -diameter (533
mm) skylight must also have a safety label complying with
Class 1, ANSI Standard Z35.1, warning of the risk of fall.
Page 3'of 5 ESR -2253
TABLE 1—SOLATUBE SKYLIGHT MATERIAL COMPONENTS
COMPONENTS'
MATERIAL
THICKNESS
(Inch)
10 -Inch
SKYLIGHT MODEL
14 -Inch
21 -Inch
Outer dome?
Acrylic'
0.125
X
X
—
Inner dome
Acrylic'
0.115
X
X
—
Dome?
Acrylic'
0.168
=
—
X _
Support base
Galvanized or aluminized steel
0.030
X
X
X
Turret extensions
Galvanized or aluminized steel
0.030
X
X
X
Round -to -square transition
PVC
0.060
—
—
X
Round -to -square transition
Acrylic
0.100-
—
—
X
Dome edge protective ring `
Galvanized or aluminized steel
0.030
X
X
X
Tile roof kit
Dead soft, pleated aluminum_
0.020
X
X
—
Reflective tube
Aluminum
0.015.
X
X
—
Reflective tube
Aluminum_
0.018.
—
—
X
crylic Light diffuser2
Acrylic
0.100
X
X
X
Optiview diffuser2
Polycarbonate
0.022
X
X
X
For SI: 1 inch = 25.4 mm.
'Plastic dome materials conform to products specified in the approved quality control manual..
ZClassification CC -2:
'Classification CC -1:
°Thickness prior to thermoforming.
ITEMNO>
' TY
DESCRIPTION
1 " _
1 OUT.R' MME'
2.• -
.1.1NNER(DOME
3. - 1
I:..
LIGHT'IRACKER
DOME EDGE.P.ROTECTION;BAND'
o::
A 1 SCREW48Y.1"
7" .—..
.4, _
D,OME'RING SPACER
8'-
4.
. TOR''7UBE''CUP
2
'A
•SCREW#;IOXZ•'SMS'
1'0
711.1
"FLASHING- PFCHED
gilt
I`..
TOP TUBE
: � 1::.; .'
: TUBE 1!6":EXTENSION `
13:
1.
BOTT.OM,TUBE
14
:4 _ "
SCREW #Bsx'a' S"'SMS
15: ...-.
4'---
CLAMP'
14
l:
CEILING,RIN .
`17'"
T
DUAL;GLAZEDIFFUSER'
d8
I
DRESS'RING
1?
1
DIFFUSER PANEL
CURB flA3HING " ''
",USE I81 :aQ'TEK;S_CREWS FQR;[v1ETAL,ROO'F
" UNIVERSAL TIME A,'SHIMG; ,+ r
i . ,, FIGURE 1-`160 DS AND 290 DS SOLATUBE WITH DETAILS .
Page 9 of 5 ESR -2253
ry'i
TION
git
'OPEN PifFUSEZ
ITEM (- ?Tr'
8,CREW4. s
.GLAZI-NO
6,,
-A
1LSHING
V5*
I
fJTW1"AEFCECTCiRi'
8�1+1-
1-61
SC,'REW- J0, 2-11�5m$
A4 A.0A
xu��,�.uoba- NotE� FIER, •
f
TMBOTTO""
12'RT,$lRA,.NSlTl-ON.,Zl.`-
it «
CJ
NS, EAL
15
a
RTS LENSJAZ
1.6
:1
NAtuRAL�FFOCTSIEN5
L I Y I FO R -OP EN C EldKbA..,O.PbQA-Jl,0,N,.-S,.
5m #off ARS Ef-AL"ROOF
FA.STEN
FOR,KA's*HING,(OP7IONAQ,
cQR�,flMIN&
FIGURE 2—SOLAMASTER/330 DS WITH DETAILS
,mp,-F,T,dH,:FL*SHlNG.
-
/.'" 11 1,. • -
. BVILDING ENERGY';ANALYSISMREPOR"
'PR°EJECT':'
Mr. &Mrs Brengle
7:8631 •Talking'Ro'ckTurnt<
:La Qumta; Ca 92253
Design Mind Studio ,
` By: Gordon Stein
74-794 - 42 - Avenue Suite # 6'
} Palm, Desert, CA 92260
',
Telephone:,, •-1-(760) 773-4488,,.
Prepared
°Santiago, Lopez Ocam po' 7
_r rfD
C Ub d L
"0 B"b"1018p
r 4 ,t5
r La Qurnta,_rCa 92247*a! AUG 0 3 2012
•
7,60 TV58-�27 • '4^Y
y -_
- .. f, i'
By ---------------
. - , ` �� { . : � -Date,:;. ,;.• ,
1 , .. 4, ' • _ ' ` : ;,:7123/2.0.'1'-2, f ,1 • �9`rL �,l �.
.� y .y 4 +« j�ol .,)• . `d.. J. , l.S }SY 3 P F. f? f -.+ .'.i 1.• -•�
The,Enerr�yProaomputertprogram,hasbeen dbperformthecaicutatonssummanned,inth�saomphanae report Thrsprogramhas•approvalandis,
authon�edbythe:GalAomra,EnergyComm�ssionforu'sewdh'lioththp Resbentraland Non�es�dent�a12008'BuildingEnenyEffviencyStandards:
.. l.. t •. -.,L -h •• i Q :Y� '.i -'r:.. .1.. -i .. 7' � A.�. �. '. ,
_.. .. ' 1' Th�s,p��ogiamdeve'bped'by EneigySoft,'LLC � wwwene'rgysoft:aom?<
Y Erre"""P.ro;�a?,b .Err', SStt': tkeraUrJweRier.57,.32< '• RutzCoo'e;`20.?2>07=23 TO&'?'4.90.
ID.40773,12-'
R
z
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 10
HVAC System Heating and Cooling Loads, Summary. 13
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Mr. & Mrs Brengle
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
7/23/2012
Project Address
78631 Talking Rock Turn La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,937
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes 0 No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade None 5,937 Perim = 0' Existing
Wall Wood Framed R-13 7,170 Existing
Door Opaque Door None 24 Existing
Roof Wood Framed Attic . R-19 5,936 Existing
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Right (NM 261.0 0.550
0.67 none none Bug Screen Existing
Rear (SW) 298.0 0.550
0.67 none none Bug Screen Existing
Left (SE) 168.0 0.550
0.67 none none Bug Screen Existing
Left (SE) 8.0 0.550
0.67 none none Bug Screen Removed
Left (SE) 40.0 0.340
0.22 none none Bug Screen New
Left (SE) 48.0 0.370
0.17 none none Bug Screen New
Front (NE) 36.0 0.340
0.22 none none Bug Screen New
Front (NE) 168.0 0.550
0.67 none none Bug Screen Existing
Skylight 0.5 0.430
0.30 none none None New
Skylight 0.5 0.430
0.30 none none None New
Skylight 0.5 0.430
0.30 none none None New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
5 Central Furnace 78% AFUE
Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC System Ducted
Ducted Attic, Ceiling Ins, vented 8.0
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Energ Pro 5.1 by EnergySoft User Number: 5732
Run Code: 2 0 12-0 7-23 70 8:14:40 ID: 1072312
Page 3 of 13
PERFORMANCE CERTIFICATE:, Residential`'`." (Part 2 of 5) CF -1 R
Project Name
Mr. &Mrs Brengle
Building Type ® Single Family ❑ Addition Alone
' ❑ Multi.Family ❑ Existing+ Addition/Alteration
Date
7/23/20;12
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
'justification and documentation; and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted. '
The Existing Furnace Default FAU/AC 1992 - 2005 has an AFUE less than the.Vintage Defaults. field verification is required.
The Existing Air Conditioner Default FAU/AC 1992 - 2005 has an SEER less than the Vintage Defaults. Field verification is required.
HIGH MASS Design - Verify Thermal Mass: 5,937.0 fN Exposed Slab Floor, 3.500" thick at Whole House
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
corn leted CF -4R form for each of the measures listed below for final to be given.
r,
Ener Pro 5.1 by Ener Sof User Number: 5732 RunCode: 2 01 2-0 7-23 708:14:40 ID: 1072312 Page 4 of 13
0
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family O Addition Alone
Date
Mr. & Mrs Brengle
I I O Multi Family O Existing+ Addition/Alteration
1712312012
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/tt2- r
Space Heating 7.88 5.21 2.67
Space Cooling 170.21 165.14 5.07
Fans 29.66 28.49 1.17
Domestic Hot Water 6.14 6.14 0.00
Pumps 0.00 0.00 0.00
Totals 213.89 204.98 8.91
Percent Better Than Standard: 4.2
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (NE) 45 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (NE) 3,152 204
Fuel Available at Site: Natural Gas (SE) 1,908 256
Raised Floor Area: 0 (SK9 1,246 298
Slab on Grade Area: 5,937 (NM 1,906 261
Average Ceiling Height: 11.0 Roof 5,937 2
Fenestration Average U -Factor: 0.53 TOTAL: 1,021
Average SHGC: 0.61 Fenestration/CFA Ratio: 17.2%
REMARKS `
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Santiago Lopez-Ocampo 7/23/2012
Address P.O. Box 1018 Name
City/State/ZipCity/State/Zip La Quinta, Ca 92247 Phone 760.485.8927 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Design Mind Studio
Address 74-794 - 42 Avenue # 6 Name Gordon Stein - 5-12
City/State/Zip Palm Desert, CA 92260 Phone 1-(760) 773-4488 Sigid License # Date
Ene Pro 5.1 b Ener Soft User Number: 5732 RunCode: 2012-07-23T08:14:40 /D: 1 072312 Page 5 of 13
CERTIFICATE OF COMPLIANCE:
Residential
(Part 4 of 5) CF -1 R
Project Name
Mr. & Mrs Brengle
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
7/23/2012
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
5,937
0.730 None
0
180 Existing 4.4.7-A1
Whole House
Wall
1,647
0.102 R-13
315
90 Existing 4.3.1-A3
Whole House
Wall
948
0.102 R-13
225
90 Existing 4.3.1-A3
Whole House
Wall
1,652
0.102 R-13
135
90 Existing 4.3.1-A3
Whole House
Wall
2,924
0.102 R-13
45
90 Existing 4.3.1-A3
Whole House
Door
24
0.500 None
45
90 Existing 4.5.1-A4
Whole House
Roof
5,936
0.049 R-19
0
18 Existing 4.2.1-A4
Whole House
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
4.0 0.550 Default
0.67 Default
315 Existing
Double Non Metal Clear
Whole House
2
Window
4.0 0.550 Default
0.67 Default
315 Existing
Double Non Metal Clear
Whole House
3
Window
36.0 0.550 Default
0.67 Default
315 Existing
Double Non Metal Clear
Whole House
4
Window
25.0 0.550 Default
0.67 Default
315 Existing
Double Non Metal Clear
Whole House
5
Window
24.0 0.550 Default
0.67 Default
315 Existing
Double Non Metal Clear
Whole House
6
Window
48.0 0.550 Default
0.67 Default
315 Existing
Double Non Metal Clear
Whole House
7
Window
48.0 0.550 Default
0.67 Default
315 Existing
Double Non Metal Clear
Whole House
8
Window
6.0 0.550 Default
0.67 Default
315 Existing
Double Non Metal Clear
Whole House
9
Window
48.0 0.550 Default
0.67 Default
315 Existing
Double Non Metal Clear
Whole House
10
Window
6.0 0.550 Default
0.67 Default
315 Existing
Double Non Metal Clear
Whole House
11
Window
6.0 0.550 Default
0.67 Default
315 Existing
Double Non Metal Clear
Whole House
12
Window
6.0 0.550 Default
0.67 Default
315 Existing
Double Non Metal Clear
Whole House
13
Window
6.0 0.550 Default
0.67 Default
225 Existing
Double Non Metal Clear
Whole House
14
Window
60.0 0.550 Default
0.67 Default
225 Existing
Double Non Metal Clear
Whole House
15
Window
48.0 0.550 Default
0.67 Default
225 Existing
Double Non Metal Clear
Whole House
16
Window 1
120.0 0.550 1 Default
0.67 Default
225 Existing
Double Non Metal Clear
Whole House
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
Hat Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
JBug Screen
0.76
16
JBug Screen
0.76
Ener Pro 5.1 by Ener Soft User Number- 5732 RunCode: 2012.07-23708:14:40 ID: 1 072312
Page 6 of 13
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name Building Type m Single Family ❑ Addition Alone Date
Mr. & Mrs Brengle ❑ Multi Family ❑ Existing+ Addition/Alteration 7/23/2012
OPAQUE SURFACE DETAILS
Surface U Insulation Joint Appendix
Type Area FactorkC7-a-y7RjTff-xterior1Frame Interior Frame Azm I Tilt I Status 1 4 1 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type
Area
Ll -Factor'
SHGC
Azm Status
Glazing Type
Location/Comments
17
Window
64.0
0.550 1 Default
0.67 Default
225 Existing
Double Non Metal Clear
Whole House
18
Window
48.0
0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Whole House
19
Window
6.0
0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Whole House
20
Window
6.0
0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Whole House
21
Window
4.0
0.550 Default
0.67 Default
135 Removed Double Non Metal Clear
Whole House
22
Window
4.0
0.550 Default
0.67 Default
135 Removed
Double Non Metal Clear
Whole House
23
Window
16.01
0.340 NFRC
0.22 NFRC
135 New
Sierra Pacific - Clad Wdw
Whole House
24
Window
48.0
0.370 NFRC
0.17 NFRC
135 New
Sierra Pacific - Clad Door
Whole House
25
Window
24.0
0.340 NFRC
0.22 NFRC
135 New
Sierra Pacific - Clad Wdw
Whole House
26
Window
36.0
0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Whole House
27
Window
6.0
0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Whole House
28
Window
48.0
0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Whole House
29
Window
6.0
0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Whole House
30
Window
4.0
0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Whole House
31
Window 1
4.0
0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Whole House
32
Window 1
4.0
0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Whole House
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t Wd
Ove hang Left Fin
Len H t LEA RExt Dist I Len
Right Fin
H t Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31
113ug Screen
0.76
32
JBug Screen
0.76
Ener
Pro 5.1 by Ener Soft
User Number: 5732 RunCode: 2012-07-23T08:14:40 ID: 1 072312
Page 7 of 13
CERTIFICATE OF COMPLIANCE:
Residential (Part 4 of 5) CF -1 R
Project Name
Mr. & Mrs Brengle
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1712312012
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor SHGC2
Azm Status Glazing Type Location/Comments
33
Window 36.0
0.340 NFRC 0.22 NFRC
45 New Sierra Pacific - Clad Wdw Whole House
34
Window 4.0
0.550 Default 0.67 Default
45 Existing Double Non Metal Clear Whole House
35
Window 36.0
0.550 Default 0.67 Default
45 Existing Double Non Metal Clear Whole House
36
Window 4.0
0.550 Default 0.67 Default
45 Existing Double Non Metal Clear Whole House
37
Window 48.0
0.550 Default 0.67 Default
45 Existing I Double Non Metal Clear Whole House
38
Window 36.0
0.550 Default 0.67 Default
45 Existing Double Non Metal Clear Whole House
39
Window 4.0
0.550 Default 0.67 Default
45 Existing Double Non Metal Clear Whole House
40
Window 36.0
0.550 Default 0.67 Default
45 Existing Double Non Metal Clear Whole House
41
Skylight 0.5
0.430 NFRC 0.30 NFRC
0 New Solatube Whole House
42
Skylight 0.5
0.430 NFRC 0.30 NFRC
0 New Solatube Whole House
43
Skylight 0.5
0.430 NFRC 0.30 NFRC
0 New Solatube Whole House
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
Window
SHGC Hot Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
33
Bug Screen
0.76
34
Bug Screen
0.76
35
Bug Screen
0.76
36
Bug Screen
0.76
37
Bug Screen
0.76
38
Bug Screen
0.76
39
Bug Screen
0.76
40
Bug Screen
0.76
41
None
1.00
42
None
1.00
43
None
1.00
Ener Pro 5.1 by Ener Soft
User Number: 5732 RunCode: 2012-07-23T08:14:40 ID: 1 072312 Page 8 of 13
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF -1 R
Project Name
Mr. & Mrs Brengle
Building Type ra Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1712312012
BUILDING ZONE INFORMATION
System Name Zone Name New
Floor Area
Existing Altered Removed Volume Year Built
HVAC System Whole House
5,937
65,307 1999
Totals .01 5,9371 01 0
HVAC SYSTEMS
System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. ThermostatType Status
HVAC System 5 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating Cooling
Duct
Duct Location R -Value
Ducts
Tested? Status
HVAC System Ducted Ducted Attic, Ceiling Ins, vented 8.0
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
Kitchen Pipe Ins
40,000
50
0.58
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
0
o
.6
0
¢ —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside Buried
Ener Pro 5.1 by Ener Soft User Number: 5732 Run Code: 2012-07-23T08:14:40 ID: 1072312
Page
MANDATORY MEASURES SUMMARY: Residential , Page 1 of, 3 . MF -1 R
Project Name.-< 'W
Date .
Mr. & Mrs Brengle -.; r .
7/23/2012
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -113, CF -1R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans. '
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned s aces'are manufactured to limit air leakage. .
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration tKat meets the requirements of 10-111 (a). -
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material.' Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the,
installation of a Cool Roof is specified on the CF -1 R Form.
*§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent Ll -factor
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§ 1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. r
'§150(d): Minimum R-13 insulation in raised wood -frame floor or. equivalent U -factor. t
1 50 f : Air retarding wrap is tested, labeled, and installed accord ing to ASTM E1677-95(2000) when specified on the CF -1R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16: '
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:' .•
150 a 1A: Masonry or facto -built fireplaces have a closable metal or lass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, o erable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor.air is vented to the
outside of the building, are prohibited. J', -
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, um isolation valve, and recirculation loo connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and'
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. '
§150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system,•or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of ,
recirculating sections of hot water pipes are insulated per Standards Table_150-13.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
J
<
§150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance; and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned s ace:.'
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar. Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoff User Number: 5732 ' ,` Run Coder 2012-07-23708:14:40 ID: lg072312 . Page 10 of 13
MANDATORY MEASURES SUMMARY: Residential , Page 1 of, 3 . MF -1 R
Project Name.-< 'W
Date .
Mr. & Mrs Brengle -.; r .
7/23/2012
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -113, CF -1R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans. '
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned s aces'are manufactured to limit air leakage. .
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration tKat meets the requirements of 10-111 (a). -
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material.' Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the,
installation of a Cool Roof is specified on the CF -1 R Form.
*§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent Ll -factor
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§ 1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. r
'§150(d): Minimum R-13 insulation in raised wood -frame floor or. equivalent U -factor. t
1 50 f : Air retarding wrap is tested, labeled, and installed accord ing to ASTM E1677-95(2000) when specified on the CF -1R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16: '
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:' .•
150 a 1A: Masonry or facto -built fireplaces have a closable metal or lass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, o erable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor.air is vented to the
outside of the building, are prohibited. J', -
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, um isolation valve, and recirculation loo connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and'
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. '
§150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system,•or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of ,
recirculating sections of hot water pipes are insulated per Standards Table_150-13.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
§150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance; and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned s ace:.'
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar. Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoff User Number: 5732 ' ,` Run Coder 2012-07-23708:14:40 ID: lg072312 . Page 10 of 13
, r
MANDATORY MEASURES SUMMARY: Residential Page 2 of 3 MF -1 R
Project Name
Date
Mr. & Mrs Brengle
7/23/2012
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 .
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2.
§150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoff User Number. 5732 RunCode: 2012-07-23708:14:40 ID: lg072312 Page 11 of 13
-' I 71
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1.R
Project Name _
Date
Mr. & Mrs Brengle
7/23/2012
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed. luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION'3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
re uirements of Sections 130, 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2012-07-23T08:14:40 ID: lg072312 Page 12 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Mr. & Mrs Brengle
Date
7/23/2012
System Name
HVAC System
Floor Area
5,937
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
5
COIL
CFM
Total Room Loads 5,461
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 0
105,079
6,686 2,139
81,335
Total Output (Btuh) 0
0
Output Btuh/s ft 0.0
6,066
3,997
Cooling System
0
0
Output per System 1
0
0 0
0
Total Output Btuh 5
0
6,686
0
Total Output (Tons) 0.0
6,066
3,997
Total Output Btuh/s ft 0.0
Total Output s ft/Ton 14,248,800.0
117,211
89,330
Air System
CFM per System
D
HVAC EQUIPMENT SELECTION
Airflow cfm
0
Default FAU/AC 1992 - 2005 4
0
0
Airflow (cfm/s ft)
0.00
Airflow cfm/Ton
0.0
Outside Air (%)
0.0%
Total Adjusted System Output 4
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0 0
Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
67 OF
67 OF 105 OF
Heating Coil
104 OF
--------
ROOM
68 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm
77 / 63 OF
77/63°F 55/54°F
i^
Cooling Coil 57 / 55 OF
48.5% � ROOM
75 / 62 OF
i d
EnergyPro 5.1 by EnergySoff
User Number. • 5732 Run Code: 2 012-0 7=2 3 708:14:40 /D: lg072312 Page 13 of 13