Loading...
0211-174 (SFD)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that l am licensed under provisions of Chapter.9 (commencing with Section 7000) of Division 3 of the ,Business and Professionals Code, and my License is in full force and effect. License # Lic. Class. / Exp.' Date 6:5 '1 PAC t' viµ. l n 4• Date ^ > Signature of-Contracrt OWNER -BUILDER DECLARATION ('hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: + I, as owner of the property, or my employees with wages as their sole ,4compensation, will do the work, and the structure is not intended or offered for ssale`(Sec. 7044, Business & Professionals Code). (:) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ). I am exempt under Section B&P.C. for this.reason Date x Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one .of the following declarations: () I have and will maintain'a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. (() I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit; is issued. -My workers' compensation insurance carrier & policy no. are: Carrier ,,TAT,. F[JkiD Policy No. 9iS1'ei�Ci.�t1i)2 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) - I .certify that in the performance of the work for which this permit is issued, Ishall`. not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to .the workers' compensation provisions of Section 3700 of the Labor .' Code; I shalliforthwith comply with hose previsions. Dated% -f i i IC>3 APPlicann J Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an -employer to criminal penalties and civil fines up to $100,000, in addition to,the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT' Application.is hereby made to the Director of Building and Safety for 'a - permit subject to the conditions and restrictions set forth on his r« application. 1. Each person upon whose behalf this application is made & each person at'� whose request and for whose benefit work is performed under or pursuant tot any permit issued as a result of this applicaton agrees to, •& shall; indemnity &, hold harmless the City of La Quinta, its officers; agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or,cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the,above-mentioned property form pection purposes. Signature (Owner/Agen,�` .r-_. Date- Ir�fi�l .BUILDING PERMIT, PERMIT# A _ 11.47 DAT VALUATION LOT TRACT �y 1r' �4 g y (� �y �/Jy a�` ell t / 4W l \'..f'U•f.�Z194 7 160 ! V JOB SITE ADDRESSu "�? aaiC1�a�Ii� rr APN YRAi OWNER CONTRACTOR/DESIGNER/EN (NEER t 1 )h C.HAT+LES 1) LA'I+.AHN . AMRIEW P;E>�h E C:OPPORA11014 ,'„(IMWAi3It.3 E Will S3217 PALW bLe�` -Jt.J . r , • CA '72,61 (760)34&34228 QB1 03031 USE OF PERMIT S:fNOTM )TAMmy Dwn :J'ING SYD, COUD'ITIt3A41t20i ARACIZ:lPALC:F.f V.1,V1C0)I,<tI1JAse4C%WITH AJ L•' . Fj��i�P�AL B'T,AT9•/ LAW%INCLUDIG THE ENDAPME11RD SPEC"IF'S.'eif"T 0.10TOM CONSTRUCTION 4,921 ,00 9F PC.11tf";I.IPATIO 621.00 ;si'r' 0ARAG19CAUOF.:f' 3F , NE'M.4017-D COST OF, CONISMUC1110N 412.947.69 CONSTRUCTION "VER 101-000.418-000 s.@�7;3g,Att PLAN CIMIC M 101-000.41:39»318. s.t'A 14.=4e KE DEPOSi"T 101-000439 31U 4147,50M MECOAPIC CALFRE 7 � - t�� 1- r o $aai,'�' F.11C.MA ,,1EE, 101 tMO.4.20.000 =16,34 I►I..F.iM,S1Nai+'I ). 161-000-4 1 "00 11233.115 . MMONO MOTION YELP .'RFAJI) 101-000-241-000 S41,29 t' 1W.RuLAPER IMPACT FEE, ART IN PlIULIC PLACES ;. P.LPME 270-I lOO-4sg5-t.' O 033,39 M G+ y 41,250,00 eFEB 1 k RECEIPT DATE BY "":/ DA F L INSPECTOR INSPECTION RECORD OPERATION j DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs 3,_/_- U—? Underground Ducts O Forms & Footings G Ducts Slab Grade Return Air Steel Combustion Air Roof Deck _� _ _ Exhaust Fans O.K. to Wrap - _ O F.A.U. Framing_// _ Compressor Insulation — O Vents Fireplace P.L. _ _ Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final BLOCKWALL APPROVALS Steel POOLS - SPAS Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final I I Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover $ewer Connection _ ��� G� Encapsulation Gas Piping Gas Test Appliances Final Final Utitity Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: J'�"— %���.,n�.J/��1j dGL Ga ?N ��ilG►+— / � l CERTIFICATE OF COMPLIANCE J�lFsc . s Desert Sands Unified School District �o�cSo I. 47950 Dune Palms Road I' �� .Q BERMUDA DUNES C RANCHO`MIRAGE d. Date 2/11/03 La Quinta, CA' 92253 - w INDIAN WELLS ` No. 24137 (760) 771-8515 d� PALM'DESERT Cl) INOIO Owner. M/M .Charles P Labahn • y . APN•#. ,773-360-004 , Address 1400 West Calumet Court ,Jurisdiction La Qui6ta City Milwaukee., 'Zip 53217, Permit # 0211-174' > Tract # 28667 F r • r Study Area F Type- Single Family Residence-.No.�of Units 1 Lot # No. Street. S.F.Lot-# No. ,, Street S.F. Unit 1' 76 6� Troon Trail' 5998 Unit- Unit'2° T' 53,2.25 `* Unit 7 , Unit 3 »' : ,• , Unit 8 Unit 4 Unit 9 ' Unit 5 Unit 10 a - Comments Above includes'A/C Garage totaling 1,073'SQ.. f At the present time; the Desert Sands Unified School District does riot collect fees-on garages/carports, covered patios/walkways, residential additions` under 500 square "feet,. detached accessory struct6res;(spaces that do not contain facilities for living, sleeping, cooking; eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: s EXEMPTION'NOT APPLICABLE . . r -This certifies that school facility fees imposed pursuant to Education. ode Section 17620 and Government Code 65995 Et Seq. in, the amount of $2.14X 5,998 S.F. or $12,835:72 have been paid for.the property listed above and that. building permits and/or Certificates of Occupancy for this square footage in this,proposed project may now be issued. . Fees Paid By CC/Palm Desert Natl Bank - Autumn Johnsori Check No. 085634 Name on the check Telephone 760-346-3228 . r` Funding: Residential r r. - -By Dr. Doris Wilson Superintendent ., .. Y - MI• - ' � ;• .. ti ,�I, .. a .. �� ' "— � •` 1 , • . Fee collecte;Iex7 aron McGilvrey� $12835:701 2 Payment Recd Over/Under ;• Signature. ; NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or uother payment identified above will begin to run from the date on'which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.. . NOTICE: This Document NOT VALID if Duplicated F ' Embossedbriginal = Building Department/Applicant • Copy - Applicant/Receipt Copy - Accounting' CI3� _ iA ����,FEB-119 . RECD ��\ o ,' ` a )w. BERMUr BUILD 8 DADUNES RANCNOMRAOE2 -Desert Sarids Ulifed, SC1LL u1. 5•• ` 7�i•�C "q}l�, 6 INDIAN WELLS oy 47-9'50 Dune -Palms Road • La,Quinfa. California 92253 �; (760), 777-4200 PALM DESERT `► „ • LA OUINTA �a fi -• + w INDIO February f2; 2003 Ed Randall r 4 Building and Safety Department City of La Quinta.,, r P.O: Box. 1.504 La Quints,CA 922534504' RE: Building Permit #0211-174/Our Certificate # 2413 for Single Family.Dwelling at 53225 Troon- Trail. r Dear Ed, ' The certificate of `compliance I issued for developer fees on February, l 1 `was typed with the incorrect address of 53255 Troon Trail. The address should read 53225�Tioon_°-Tiail.7 Please accept this letter as a;correction of this error.; If anything furthei"s needed, please call me at 871 '8521.. y �t ` Thanks again,Ed.." r - ` Sharon McGilvrey Office Tech ciari + , i Facilities Services r - t, �.> 'f it •. . r„ tY, r";y _ .: ,.. y: .., ,. t ' Y+ C•i ;i!' �, i•"r • ; . .. .. Jr�ftEp 4 � •. '1 , ' _ `\�����//mac o „ • • . - - RENCNO WRAOMUDADUNES RAr •Desert Sands Unified School 'District , - De IND�NwEusE ,V' 47-950 Dune•Palms Road �nLa Quinta,'California 92253 • (760) 777-4200 r, d PAY DESERT "r r a s. • - •LA OUINTA'�a •"" -. �'. �, s f .R. _ . .y . INDIo L + 91TY 0 4_A 01 Ml JTA r FEB 2 0•RECT February17,' 2004 Bl1!l�6Ee�c •-y- >f 41 o ' Autumn Johnson /I Andrew Pierce Corp:*. P -.O. Box 3420 Palm Desert, CA 92261 �, P Dear Autumri,' v �I Enclosed you will fund eck "in the amount of $2,296.22 for the Labahn residence located a 5322.5 Troon,Tr� ` in L aI Quinta. This is a partial reimbursement for ' f4 V the developer fees pai a ruary 11th, 2003 .which included 1,073 sf of garage space that'was planned for au• conditioning (copy, of certificate enclosed). Since the decision was -,made• not to -install'air conditioning,• the garage space is "then exempt from any •developer fees. If you have, any questions, please call me at.771.8521. ' Sincerely; k , y Y: Sharon M ilvreY Office Specialist Facilities Services /enc cc t&klkndall, Counter,Teclin cian, City of LaQuinta, Building & Safety Department • i CERTIFICATE OF COMPLIANCE Desert Sands Unified School District z4�c�o ' 4.7950 Dune Palms Road ' Q- BERMUDA DUNES r +r * RANCHO Date 2/11/03 0 La Quints; CA 92253 � INDIAANN WELMIRWELLSS 760 771-8515 PVNDIO QUINTAT y 24137 � � o' Owner' M/M Charles P Labahn APN # 773-360-004 Address 1400 West Calumet Court Jurisdiction La Quinta Ci Milwaukee Zi 53217 O Permit # ' , 0211-174 ty p Tract # 28667 Study Area • Type Single, Family. Residence M No. of Units Lot # No. Street S.F. Lot # - No.. Streets.. S.F. Unit 1 76 . 53225 • Troon Trail, . 5998 Unit 6 x Unit 2 Unit 7 ' Unit 3 Unit 8 Unit 4 Unit 9 `.•Unit 5 Unit 10 ,Comments Above includes A/C Garage totaling -1,073 SQ. ? 03/04;-_direct;`pay,issued-in.the amount of $2 296.22.as.a reimbursement for -garage since it was not a/c. Check mailed to Andrew°Pierce-Corp:;PO"Box 3420;PD92261 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet,'detached accessory, structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to , Education Code Section 17620 and Government Code 65995 Et-Seq: in the amount of $2.14 X 5,998 S.F. or $12,835.72 have been. paid for the propertylisted above and that , building permits and/or. Certificates of Occupancy for -this square footage in this proposed project may now be issued. ' Fee's Paid By ' CC/Palm'Desert Natl Bank - Autumn Johnson Check No. 085634 r Name on the check Telephone 760-346-3228 ' Funding.' Residential By ,t . .,Dr. (Doris Wilson Superintendent , Fee collected./exempted by -Sharon; MCGilvrey Payment Recd $0.00 {' . ' $12,8.35:72 over/Under Signature ' NOTICE: Pursuant to GovemmentLode Section 66020(4)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or' other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s)or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT -VALID if Duplicated . ` Embossed Original'- Building DepartmenUApplicant Copy - Applicant/Receipt , Copy, -,,Accounting ; ` . r I ,SPECIAL REGISTERED INSPECTOR'S WEEKLY REPORT JON TANDY 37630 Medjool Ave. Palm Desert, CA 92211 Office (760) 772-7192 Fax (760) 772-7193 Pager (760) 776-3338 TYPE OF INSPECTION PERFORMED ❑ REINFORCED CONCRETE ❑ STRUCT. STEEL ASSEMBLY ❑ POST TENSIONED CONCRETE ❑ ASPHALT ❑ REINFORCED MASONRY ❑ FIRE PROOFING -@K ❑ OTHER JOB LOTION 5I -22S T��� i��1 'oma REPORT SEQUENCE NO. TYPE OF STRUCTURE s FDk PERMIT NO.' `_ OATS Zo (3 DAY OF ;EEK MA PIAL DESCRIPTION 145 ARCHITECT INSFIECTOR HRS. CHARGED 2 ® ENGINEER O f ASSISTANTS HRS. CHARGED INSPECTION DATE GENERAL SUB CONTRACTOR G7 CONTRACTOR �0 20 4pS-WJCA -c, - F S - 4t4 r �b�L �• ; x:s�� � Mme, -�� ire-�.`� f �� • cam.. ���:�� S —� . � • ire . � y c�a� ei� S �- cT� e - ` N, S COPY SENT TO CLIENTD CONTINUED ON NEXT PAGE D PAGE OF CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF MN KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS. SPECIFICATIONS. AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS. C'�o. IGNATE OF REGISTERE INSPECTOR —� 21 c2-3 is s prr-eq DI TE OF EPORT REGISTER NUMRFR I A x Bin # I City of La. Quinta Building 8 Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address:5-3 yezoy��?,n l 0%%-ner's Name: Q,i, A. P. Number: Address:bH.-�1� lCitv. Leeal•Description:� Contractor: Y2t_�JwtA ST. Zrp:rn FTelephonclw • �•- ' = Address:6qs/ - ' t5 ! `�/1 City, ST, tp: Telephone• 1Lo -341,, 3��� Project Description e— 4 (' ! O State Lic. # : City Lic. : Arch., Engr., Designer: l l Address: Cite. ST. Zip: Telephone:-:°•:: State Lic. #: Construction Type. Occupancy: Project type (circle one): New Acid'n Alter Repair Demo Name of Contact Person: —. n��y�Su`�r� Sq. Ft.: ay Stories: # Units: Telephone # of Contact Person: 110 q stimated Value of Proiect: APPLICANT: DO NOT WRITE BELOW THIS LINE tt Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural C21cS. Reviewed, ready for corrections Plan Check Deposit Truss C21cS. Called Contact Person Plan Check Balance Energy Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for correctionssuc, )3-9); Electrical Subcoataetor List Called Contact Person/\ Plumbing Grant Deed Plans picked up SAI 1 H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '" Review, ready for correctionstissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees A Total Permit Fees REGISTERED INSPECTOR'S- WEEKLY REPORT JON TANDY 37630 Medjool Ave. Palm Desert, CA 92211 Office (760) 772-7192 Fax (760) 772-7193 Pager (760) 776-3338 TYPE OF INSPECTION PERFORMED ❑ REINFORCED CONCRETE ❑ STRUCT. STEEL ASSEMBLY Epp' y o,( ❑ POST TENSIONED CONCRETE ❑ ASPHALT ❑ OTHER ❑ REINFORCED MASONRY ❑ FIRE PROOFING JOB LOCATION j -53- ZZ 5 roc �Ai \ N Q O REPORT SEOUENCE NO. TYPES OF STR ICTURE J i' p �^ `h 1►�Y+��\ 1 PERMIT NO. ` ( Z� \ \� DATE /^� WEEK .. DAY OF M4 RIAL DESCRIPTION"S ��� Moo ARCHITEC Zek INSPECTOR HRS.CHARGED % C 1 M o. . w � ENGINEER Cr C✓r ASSISTANTS MRS. CHARGED INSPECTION DATE GENERAL/� CONTRACTOR R _ l`���n SUB CONTRACTOR 23 bsizrve.A 14-5ef' ra o t \ks' bcosyyt-& (')"en co"" COPY SENT TO CLIENT O CONTINUED ON NEXT PAGE O PAGE OF CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS. SPECIFICATIONS. AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS. SI 116ATURE OF REGIST EO INSPECTOR f CP 23 3 O L �7 DAVE OF REPORT REGISTER NUMRFR lh TITLE 24 REPORT S 3- a �s l2 �zrn 7,? gag c. •. -R - 4 Title'24 Report for.: r CITY OF LA QUINTA .' La Bahn Residence BUILDING & SAFETY DEPT. of 76- Tract No. 28667 " APP OVLa Quinta, CA 92253 FOR CON U TION - -- . ---� DATE1�- BY i j Project Designer: Zehren And Associates, Inc. 4 -1: 233 E.•Canon 'Perdido St. Santa Barbara, CA 93101 (805) 963-6890 y Report Prepared By: Gina Rose - BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Job Number: Date: 12/29/2003 ! �A A The EnergyPro computer program has been used to perform the'calculationssummarized in this compliance report._ This program has -approval and is ' authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3:1 By EnergySoft Job Number: User.Number: 3665 s! t �r � .S r Certificate of Compliance: Residential (Part 1 of 2) CF -1 R La Bahn Residence R-38 Roof (R.38.2x14.16) 12/29/2003 Project Title Exterior Roof Date. 'Lot 76 Tract No. 28667 La Quinta 0.059 Project Address Slab On Grade Building Permit # , BREEZE AIR, CONDITIONING -(760)346-0855 Plan Check/Date Documentation Author Telephone 0.756 Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION X❑ ❑ Total Conditioned Floor Area: 4,962 ft2 Average Ceiling Height: 11.4 ft Total Conditioned Slab Area: 4,962 ft2 0.32 Building .Type: Bug Screen (check one or more) X❑ F X❑ Single Family Detached ❑ Addition (East) ❑ Single Family Attached ❑ Existing Building 0.49 ❑ Multi -Family ❑ Existing Plus Addition X❑ Front Orientation: (South) 180 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 248.0 Number of Stories: 1 ❑ Raised Floor -111141]NVVnI_ZI11111111111PRillWa19[01► Component Type, Frame Type . Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall Slab On Grade n/a 0.756• Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Solid Wood Door None 0.387 • Exterior Door FENESTRATION • Shading' Devices, Type Orientation Area Fenestration Exterior Overhang Side Fins (S F U -Factor ' SHGC Shading Yes / No Yes / No Rear (North) 178.0 • 0.32 0.49 Bug Screen ❑ X❑ ❑ X❑' Right (East) 412.3 0.32 0.49 • Bug Screen ❑ X❑ ❑ X❑ Right (East) 45.0 0.32 0.49 Bug Screen X❑ ❑ r X❑ ❑ Left . (West) 248.0 0.55 0.49 Bug Screen ❑ X❑ .❑ X❑ Left ' (West) 257.1 0.32 0.49 Bug Screen ❑ X❑ ❑ X❑ Left (West) 24.0 0.55 0.49 Bug Screen 0 ❑ ❑ X❑ Rear (North) 9.2 0.32 0.49 Bug Screen ❑ X❑ X❑ ❑ Rear (North) 80.0 0.55 0.49 Bug ScreenX❑ '❑ . - ❑ X❑ Rear (North) 68.1 0.32 0.49 Bug Screen X❑ ❑ ❑ X❑ Right (East) 88.0 0.55 0.49 Bug Screen ❑ X❑ ❑ X❑ Front (South) 64.0 0.32 0.49 Bug Screen X❑ ❑ ❑ X❑ Front (South) 40.0 0.55 0.49 Bug Screen X❑ ❑ ❑ X❑ Run(lnitiation Time: 12/29/03 11:10:55 Run -Code: 1072725055 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number: Page: 3 of 47 n Certificate of Compliance: Residential (Part 1 of 2) CF -1 R La Bahn Residence 12/29/2003 Project Title Date Lot 76 Tract No. 28667. La Quinta ❑ X❑ Project Address Building Permit ,# BREEZE AIR CONDITIONING (760) 346-0855 plan Check /Date Documentation AuthorTelephone ❑ ❑ Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) , Climate Zone Enforcement Agency Use.Only GENERAL INFORMATION M Total Conditioned Floor Area: 4,962 ft2 Average Ceiling:Height: 11.4 ft Total Conditioned Slab Area: 4,962 ft Building Type: ` ❑❑ (check one or more) El El Single Family Detached ❑ 'Addition , ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing.Plus Addition *. Front Orientation: (South) j80 dei Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 El❑. Number of Stories: 1 ❑ Raised Floor .Component I - FENESTRATION Const. Frame Assembly Location/Comments Type •U -Value (attic, garage, typical, etc.) Silhading Devices Type Orientation Area Fenestration Exterior Overhang Side Fin's (SF)' U -Factor SHGC Shading Yes / No Yes / No Front (South) 71.1 0.32 0.49 Bug Screen ❑ X❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ M ❑ ❑ ❑ ❑ F1 11 ❑❑ El El ❑❑ ❑ ;❑ ❑ ❑ ❑.,❑ El❑. ❑❑ El 1:1 ❑ ❑ ❑ ❑ Run Initiation Time: 12/29/03 11:10:55 Run Code: 1072725055 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number: Pa e:4 of 47 I z T, Certificate of Complian"ce: Residential (Part 2 of 2) CF -1 R La Bahn Residence 12/29/2003 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnarp 80% AFUE Ducts in Attic 6.0 Setback HVAC -1 r entral Furnace 80% AFUE Ducts in Attic 6.0 Setback HVAC -2 Central Furnace 80%AFUE Ducts in Attic 6.0 Setback HVAC -3 CPntral FurnarP 80% AFUE Ducts in Attic 6.0 Setback HVAC -4 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location'/ heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 13.0 SEER Ducts in Attic 60 Setback HVAC -1 Split Air Conditioner 13-0 RFER Ducts in Attic 6.0 Setback HVAC -9 Split Air Conditioner 13.0 SEER Ducts in Attic 6.0 Setback HVAC -3 Split Air Conditioner 13.0 SEER Ducts in Attic 6.0 Setback HVAC -4 WATER HEATING SYSTEMS " Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O. SMITH FPS -75-230 Small Gas Recirc/Time+Temp Z— 75,000 75_ 0.52 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. , For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. RFMARKC COMPLIANCE STATEMENT " This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations,. and the administrative regulations to implement them. This certificate has.been signed by the individual with overall design'responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) ' Documentation Author Name: Name: Gina Rose Title/Firm: Zehren And Associates, Inc. Title/Firm: BREEZE AIR CONDITIONING Address: 233 E. Canon Perdido St. Address: 75-145 ST. CHARLES PLACE Santa Barbara, CA 93101 PALM DESERT, CA 92211 Telephone:. (805) 963-6890 Telephone: (760) 346-0855 Lic. #: r 1 f �'J„ /0 I • 12 9 13 (signature) ((date) (signal ) (dit ) Enforcement Agency - Name' Title/Firm: Address: l Telephone: I EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:5 of 47 1 Certificate of Compliance: Residential (Addendum) CF -1 R La Bahn Residence 12/29/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The DHW System "A.O. SMITH FPS -75-230" Energy Factor = 0.520. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -1" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 509 sqft Exposed Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C-213) - Verify Thermal Mass: 796 sqft Covered Slab Floor, 3.50" thick at Master Suite The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -2" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1844 sqft Exposed Slab Floor, 3.50" thick at Living Zone HIGH MASS Design(see C -2R) - Verify Thermal Mass: 676 sqft Exposed Slab Floor, 3.50" thick at Living Zone HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field The HVAC System "HVAC -1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:6 of 47 1 Certificate of Compliance: Residential (Addendum) CF -1 R La Bahn Residence 12/29/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -3" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -3" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 202 sqft Exposed Slab Floor, 3.50" thick at Bedroom's 2, 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 473 sgft Covered Slab Floor, 3.50" thick at Bedroom's 2, 3 The HVAC System "HVAC -4" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -4" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -4" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be'verified. The HVAC System "HVAC -4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 462 sgft Exposed Slab Floor, 3.50" thick at Guest House HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document tine field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC -4" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 12129/0311:10:55 Run Code: 1072725055 EnergyPro 3.1 By EnergySoft User Number: 3665 • Job Number: Page:7 of 47 . . � .0 ...!'x , Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded' by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures 1 '§150(a): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. * Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑§150(c): X not apply to exterior mass walls). []*§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ®§116-17: - Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified'Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. . §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑%� §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures LA § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. a§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACOA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:8 of 47 w n I 's r Mandatory Measures Checklist: Residential (Page 2 of 2) FAF-1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X] .§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604'and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings _ greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected -by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam, insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. L §1 14: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot.. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. ® §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures RC§,150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. j § 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. • , u 3.1 By EnergySoft User Number: 3665 Job Number: Page:9,of 47 u , Computer Method Summary (Part 1 of 3) C -2R La-B.ahn ReS rhmnce Total Conditioned Volume: 56,569 ft 3 Wall_ ---192 -000.9 -0----9.0 12/29/2003 Project Title Wall_ 646 ---0-059- ---90---90 1X ❑ Date 1ot16--EactRo..28667--La_Q.uinta ❑ Wall_ ' 368 0_059 _270 90 LXJ ❑ Project Address ---J]La ❑ Wall- 546 6059 9Q Building Permit # BREEZE AIR COlVD1T10NING Wall_ 533 -0-059- 20- 9Q [9 (760) 346-0855 Door 24 --0-387- 6o 90 Documentation Author ❑ Wall- 56.5_ -0059 180 9.0_ Telephone Plan Check/Date Com puier�erformaace IN ❑ 15 X Field Check/Date Compliance Method (Package or Computer) 1K Climate Zone Wall- 50 0.059 90. 9.0 Source Energy Use Standard Proposed Compliance ❑ (kBtu/sf-yr) Design Design Margin X Space Heating 5.07 2.93 2.14 Wall- 958 ---0.-05,9- 90 9Q Space Cooling 40.49 40.41 0.09 ❑ Domestic Hot Water 5.74 7.47 -1.73 - ❑ Totals 51.31 50.81 0.50 Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name HLV.AC-2 1�V8C_3 4,962 ft2 Single Fam Detached (South) 180 deg 1.00 1 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Floor Area Volume 1 33.05 2.520 6Z5 462 Solar Gains Y/N Roof x_,_300 -0-02,8- Total Conditioned Volume: 56,569 ft 3 Wall_ ---192 -000.9 -0----9.0 1X ❑ Wall_ 646 ---0-059- ---90---90 1X ❑ Wall- Z55 -Q-M- 180 20 n a ❑ Wall_ ' 368 0_059 _270 90 LXJ ❑ Roof -2.520 -0-028 0 0_ ---J]La ❑ Wall- 546 6059 9Q IX ❑ Wall_ 533 -0-059- 20- 9Q [9 ❑ Door 24 --0-387- 6o 90 X ❑ Wall- 56.5_ -0059 180 9.0_ ❑ Walf 550 6059 90 IN ❑ -2.7_0 Roof 67-5 -0-02.8- 0 0 X ❑ Wall- 40 0.059 0. 90_ 1K ❑ Wall- 50 0.059 90. 9.0 IX ❑ -Wall ----.160 _00.59 180 9.0 [ X ❑ Wall_ 300 -0._0.59_ -2.7.0_ 9.0_ IX ❑ Roof _462 0 028. 0 0_ X ❑ -Wall _ x.90 -0-059 0 90 ❑ Wall- 958 ---0.-05,9- 90 9Q ❑ Wall- 157 0.05.9 X89 60 iia ❑ Wall_ 279 -0-059 _270 90 IN ❑ ❑ ❑ ❑ ❑ F 17 ❑ ❑ ❑ ❑ ❑ ❑ 13,833 _3.0.,99.6 6,750 4990 Floor Construction Type: ❑. Raised Floor X❑ Slab Floor Total Fenestration Area: 31.9% Total Conditioned Volume: 56,569 ft 3 Total Conditioned Slab Area: 4,962 ft 2 # of Thermostat Vent Units Zone Type Type Hgt. Area -0.26_ Sleeping- _SleepingS.tat_ 2 n a 0-51. Living _Living.Stat_ _nLa 0.14_ Sleeping -Sleeping-Stat- -nLa 0-09 Sleeping -Sleeping-Stat-- 2 ---J]La Form 3 Reference _&3 -8 -Roof (R.38.2x14.16) R21_Wall (W21 2x616.) R-21 Wall M/.212x616) R2LWall W -21.2x616) R2LWaIL(W.212x616) R_38_BooL(R 3"8.2x]_4..16.) R-21 Wall (W.21 - x.6-16) R21_Wa114N 21.2x616) S.olid_1N_oodJZoo r R-21 Wa11 (w 21 2x6 163) B2LWaIL(W.21 2x6.16) B_38Booi (B 3$2x]416) R-21 Wall M.21.24.16) R2]_WaI-(W_21_2x616) R2LWalL(W_212x616) R21 WaIL(W-912x616) R3812o_of-(B 'AR .2x1416.) R2LWa1L(W 2-1- JR) R2LWa.ILpN 212x6.16) R2LWall 21.2x6161 .R2LWal14M2-1_2x6_16) Location / Comments -Master-S ' . Master_SuitP Master_Suite MasteLSuite Master -Suite livinn 7 e Living Zone Livin- ne Living -Zone livinn 7nne Living Zone Bedrooms 9. Bedroom's -2r3 Bedroom's 2,B Bedroom's -2_3 Bedroom's 9. 3 guest blouse Guest -House -Guest-House_ G.uestllouse EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:10 of 47 1 Computer Method Summary (Part'2 of 3) C -2R La Bahn,Residence 12/29/2003 Project Title i. Date FENESTRATION SURFACES Bug Screen 0.76 • 2 Bug Screen 0.76 U_ Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1 Window- Rear (Nom 8.0_0 _0320 -049 0_ _9.0. Anderson -H-. Performance_ _MasteLS.uite 2 Window Right (East) 20.0 0.320 0.49 90 90'Anderson High Performance Master Suite 3 Window. Right (East) 20.0 a 0.320 0.49 90 90, Anderson High Performance Master Suite 4 Window- Right (East) 45.0 0.320 0.49 90 90 Anderson High Performance Master Suite 5 Window. Right (East) 8.7 0.320 0.49 90 90 Anderson High Performance . Master Suite 6 Window Right (East)_ 20.0 0.320 ' 0.49 90 90 Anderson High Performance Master Suite 7 Window: Right (East)_ 24.•0 -4.320 0.49 90 9Q Anderson High Performance Master Suite 8 Window Left (West) 80.0 0.550 _ 0.49 270 90 Anderson High Performance Master Suite 9 Window Left (West). 7.6 0.320 0.49 270 90 Anderson High Performance Master Suite' 10 Window Left (West) 24.0 0.550 0.49 270 '90 Anderson High Performance Master Suite 11 Window' • Rear (North) 9.2 0.320 0.49. 0 90' Anderson High Performance Living Zone 12 Window Rear (North) 80.0 0.320 0.49 0 90 Anderson High Performance Living Zone -13 WindQw_Rear (Noah) -40.0- 0-550 -0.40 1 90 Andetson_H.igb P-ejforman-ce living. -Zone 14 Window' Rear North 22.7. 0.320 0.49 0 90 Anderson High Performance Living Zone 15 Window Rear (North) 22.7 0.320 0.49 0 90,Anderson High Performance Living Zone 16 Window Rear (North) 22.7 0.320 0.49 0 90 Anderson High Performance Living Zone 17 Window Rear (North) 40.0 0.550 0.49 0 90 Anderson High Performance Livinq Zone 18 Window Rear(North) 6.0 0.320 0.49 0 90 Anderson High Performance Living Zone _Q Window Rear (North) 6.0 0.320 0.49 0 90 Anderson High Performance Living Zone 20 Window Rear (North) 6.0 0.320 0.49 0 90 Anderson High Performance Living Zone 21 Window Right (East)- 40.0 0.550 0.49 90 90 Anderson HighL Performance Living Zone 22. Window Right (East) 18.0 0.320 0.49 90 90 Anderson High Performance Livin Zone 23 Window Right (East) 20.0 0.320 0.49 90 90 Anderson High Performance Living Zone 24 Window • Right East 20.0 0.320 0.49 90 90,Anderson High Performance . Livin Zone ' 25 Window Right East 20.0 0.320 0.49 90 90 Anderson High Performance Living Zone 26 Window Right (East) 20.0 0.320 0.49 90 90 Anderson High Performance Living Zone 27 Window Right (East) 24.0 0.320 0.49 90 90 Anderson High Performance Living Zone 28 Window Right (East) 48.0 0.550 0.49 '90 90 Anderson High Performance Living Zone 29 Window' Right •(East) 24.0 0.320 0.49 90 90 Anderson High Performance Living Zone INTERIOR AND EXTERIOR SHADING' Window - Overhang Left Fin Right Fin # Exterior Shade Type _ SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 • 2 Bug Screen 0.76 3 Bug Screen 0.76 '- 4 --Bug Screen 0.76 7.5 6.0 2.0 '0.1 2.0 2.0 0.1 2.0 0 0.1 2.0 0 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen - 0.76 �• 9 Bug Screen 0.76 10 -i _1 Bug Screen 0.76 8.0 3.0 10.0 0.1 10.0 10.0 • Bug Screen 0.76 5.0 1.8 r 0.1 4.0 - 0 0.0 0.0 0 12 Bug Screen' 0.76 13 Bug Screen 0.76 8.0 5.0 10.0 0.1 10.0 10.0 14 Bug Screen 0.76 _-8.0 2.8 10.0 0.1 10.01 10.0 ' 15 Bug Screen 0.76 8.0 2.8 10.0 0.1 10.0 10.0 16 Bug Screen 0.76 8.0 2.8 10.0 0.1 10.0 10.0 17 Bug Screen 0.76 8.0 5.0 10.0 0.1 '10.0 10.0 18 Bug Screen 0.76 - 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen - - 0.76 `22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 ' 25 Bug Screen 0.76 ° 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 Run Initiation Time: 12/29/0 11:10:55 Run Code: 1072725055 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 11 of 47 r � is Computer Method Summary (Part 2 of 3) C -2R La Bahn Residence 12/29/2003 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Am. Glazing Type Tilt Location/ Comments _3.0. Wiadow Right (East)_ X8.0 -0-32-0- 0.49 90_ _94 Anderson High Performance_ livin_a Zone 31 Window Right East 20.0 0.320 0.49 90 90 Anderson High Performance Living Zone 32 Window Right East 20.0 0.320 0.49 90 90 Anderson High Performance Living Zone 33 Window Right (East) 20.0 0.320 0.49 90 90 Anderson High Performance Living Zone 34 Window Right (East) 20.0 0.320 0.49 90 90 Anderson High Performance Living Zone 35 Window Right (East) 6.0 0.320 0.49 90 90 Anderson High Performance Living Zone 38W�tri dow Right (East)_ 6.0 0,320 0.49 90 90 Anderson High Performance Living Zone 37 Window Right (East) 6.0 0.320 0.49 90 90 Anderson High Performance Living Zone M Window Front (South) 32.0 0.320 0.49 180 90 Anderson High Performance Living Zone 39 Window Front -(South 40.0 0.550 0.49 180 90 Anderson High Performance Living Zone 40 Window Front (South) 32.0 0.320 0.49 180 90 Anderson High Performance Living Zone 41 Window Front South 6.0 0.320 0.49 180 90 Anderson High Performance Living Zone 92 Wndow_Eront_(Souih) 6.0 -0-3.2,0- 0.49 --180_ 90 Anderson Hiah eeiformanop living Zone 43 Window Front (South) 9.1 0.320 0.49 180 90 Anderson High Performance Living Zone 44 Window Left (West) 6.0 0.320 0.49 270 90 Anderson High Performance Living Zone 45 Window Left (West) 6.0 0.320 0.49 270 90 Anderson High Performance Living Zone 46 Window Left West 51.7 0.320 0.49 270 90 Anderson High Performance Livin Zone 47 Window Left (West) 24.0 0.550 0.49 270 90 Anderson High Performance Living Zone 4$ Window Left (West) 18.0 0.320 0.49 270 90 Anderson High Performance Living Zone 49 Window Left (West) 16.0 0.320 0.49 270 90 Anderson High Performance Living Zone 50 Window Left (West). 40.0 0.550 0.49 270 90 Anderson High Performance Living,Zone 51 Window Left West 16.0 0.320 0.49 270 90 Anderson High Performance Living Zone 52 Window Left (West) 8.7 0.320 0.49 270 90 Anderson High Performance Living Zone 53 Window Left (West) 10.5 0.320 0.49 270 90 Anderson High Performance Living Zone 54 Window Left (West) 10.0 0.320 0.49 27090 Anderson High Performance Bedroom's 2. 3 55 Window Left (West) 20.0 0.320 0.49 270 90 Anderson High Performance Bedroom's 2, 3 56 Window Left (West) 40.0 0.550 0.49 270 90 Anderson High Performance Bedroom's 2, 3 57 Window Left (West) 20.0 0.320 0.49 270 90 Anderson High Performance Bedroom's 2, 3 58 Window Left (West) 20.0 0.320 0.49 270 90 Anderson High Performance Bedroom's 2, 3 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 Y5, Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 8.0 4.0 2.0 0.1 2.0 2.0 39 Bug Screen 0.76 8.0 5.0 2.0 0.1 2.0 2.0 40 Bug Screen 0.76 8.0 4.0 2.0 0.1 2.0 2.0 . 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 Bug Screen 0.76 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 58 Bug Screen 0.76 Run Initiation Time: 12/2910311.10.55 Run Code: 1072725055 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 12 of 47 Computer Method Summary (Part 2 of 3) C -2R La Bahn Residence 12/29/2003 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments _59 Wiadow-LefL-Mest) --AOA 0_550 -O-4R _270_ -9.0. Aaderson H.ighP_erfomlance _3.edtoom's2, 3 60 Window Left (West) 20.0 0.320 0.49 270 90 Anderson High Performance Bedroom's 2. 3 61 Window Left (West) 10.0 0.320 0.49 270 90 Anderson High Performance Bedroom's 2. 3 ' 62 Window Right (East) 7.5 0.320 0.49 90 90 Anderson High Performance Guest House 63 Window Right (East) 22.5 0.320 0.49 90 90 Anderson High Performance Guest House 64 Window Right (East)_ 22.5 0.320 0.49 90 90 Anderson High Performance Guest House 65 Window Right (Ea -51L 9.1 0.320 0.49 90 90 Anderson High Performance Guest House 66 Window Front(South) 50.0 0.320 0.49 180 90 Anderson High Performance Guest House 67 Window Left (West) 9.1 0.320 0.49 X27 �0 Anderson High Performance Guest House 68 Window Left (West) 7.5 0.320 0.49 270 90 Anderson High Performance Guest House 69 Window Left (West) 24.0 0.550 0.49 270 90 Anderson High Performance Guest House INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len: Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 62 Bug Screen 0.76 63 Bug Screen 0.76 64 Bug Screen 0.76 65 Bug Screen 0.76 66 Bug Screen 0.76 67 Bug Screen 0.76 68 Bug Screen 0.76 69 Bug Screen 0.76 Run Initiation Time: 1212910311:10:5 Run Code: 1072725055 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 13 of 47 Computer Method Summary.- (Part 3 of 3) C -2R La Bahn Residence 12/29/2003 Project Title Date THERMAL,MASS FOR HIGH MASS DESIGN Area Thick. Heat ? . Inside Location Type (sD (in.) Cap. Cond. ,Form 3 Reference R -Val. Comments CQncrete. Heavyweight _5.0.5 _3_50 _28 0._98. n/a 0_ _MasteLS-uiteLSlab-orLGlade Concrete. Heavvwei hg t 796 3_50 ' 28 0_98 n/a 2 Master Suite %Slab on Grade Concrete, Heavyweight_ 1.844 3_50 28 0_98 n/a 0 Living Zone / Slab on Grade Concrete, Heavyweight 676 3_50 28 0.98 n/a 0 Living Zone / Slab on Grade Coacrete 13eaWw_eight 202 3.50 28 0.98 n/a 0 Bedroom's 2.3 / Slab on Grade PERIMETER LOSSES F2 'Insulation Type Length Factor R -Val- Depth. Location /,Comments Slab Perimeter 28 076 0.0 0 Master Suite S1ab_eelime1er x41 -0.76. _0.9. _-0 MasteL cite E Slab Perimeter 229 0.76 0.0 0 Living Zone Slab-Berimetef _59 O9-6 2 Q 2 Lwmg_Zoae -Slab-Berimeter • 39 0_76 0.0 0 Bedroom's 2 3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location ` Duct Thermostat Location / pump, etc.)'" (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80° A E Ducts in Attic 60 'Setback HVAC -1 Central Furnace 80%AFUE Ducts in Attic 6.0 Setback HVAC -2 _ Central Furnace . 80%AFUE Ducts in Attic 6.0 Setback HVAC -3 + Central Furnace 80% AFUE . Ducts in Attic 6.0 Setback HVAC4 F Hydronic Piping Pipe Pipe Insul. - System Name Length Diameter Thick. Cooling Equipment .,, Minimum Duct • Type (air conditioner, Efficiency Location Duct Thermostat' Location heat, pump,evap. cooling) (SEER) (attic, etc,) R -Value Type Comments ' Split Air Conditioner 13.0 SEER Ducts in Attic .6.0 Setback HVAC -1 Split Air Conditioner 13.0 SEER Ducts in Attic 6.0 Setback HVAC -2 Split Air Conditioner 13.0 SEER Ducts -in Attic - 6.0 Setback HVAC -3 Split Air Conditioner 13.0 SEER Ducts in Attic 6.0 Setback HVAC -4 WATER HEATING SYSTEMS Ratedl Tank'''Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution #in Input Cap. or RecoveryStandby R -Value System Name Type Type Syst. (Btulhr) (gal) Efficiency Loss (%) Ext. A.O. SMITH FPS -75-230 Small Gas Recirc/Time+Temp— 2 75,000 75. 0.52 n/a 12 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. Forlarge gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. I EnergyPro 3.1 By EnergySoft User Number:. 3665 Job Number: Pa e:14 of 47 Computer Method Summary (Part 3 of 3) C -2R La Bahn Residence 12/29/2003 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond., Form 3 Reference R -Val. Comments or Crete; Heavyweight —47-3 _3_50 —28. _028. n/a _2 .B.edmoms2,.3LS1ab_oo Grade Concrete, Heavyweight 462 3_50 28 0_98 n/a 0 Guest House / Slab on Grade PERIMETER LOSSES _ ' F2 Insulation Type Length Factor' R -Val. Depth Location / Comments Slab Perimeter 05 0.76'' 0.0 0 Bedroom's 2 3 S1ab-l?-enmeter 110 QZ6 —0-0. Q GuesilioUse HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency_ and Location Duct Thermostat. Location / pump, etc.) (AFUE/HSPF)(ducts/attic; etc.)' R -Value Type Comments f Hydronic Piping Pipe Pipe Insul. System Name Length, °Diameter Thick.'. l Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap..cooling) (SEER) (attic,.etc,) : R -Value : Type Comments WATER HEATING SYSTEMS Rated Tank Energy Factl ` Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name . Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input; and Recovery Efficiency, REMARKS. Run Initiation Time: 12/29/0311:10:55 Run Code: 1072725055 EnergyPro 3.1 _ By EnergySoft User Number: 3665 Job Number: Page: 15 of 47 'J Computer Method Summary (Addendum) C -2R La Bahn Residence 12/29/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The DHW System "A.O. SMITH FPS -75-230" Energy Factor = 0.520. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -1" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 509 sqft Exposed Slab Floor, 3.50" thick at Master Suite HIGH MASS Design(see C -21R) - Verify Thermal Mass: 796 sqft Covered Slab Floor, 3.50" thick at Master Suite The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -2" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1844 sqft Exposed Slab Floor, 3.50" thick at Living Zone HIGH MASS Design(see C -2R) - Verify Thermal Mass: 676 sqft Exposed Slab Floor, 3.50" thick at Living Zone HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -611. Plan I Field The HVAC System "HVAC -1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 12/29/03 11:10:55 Run Code: 1072725055 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 16 of 47 Computer Method Summary (Addendum) C -2R La Bahn Residence 12/29/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan I Field The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -3" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -3" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) Verify Thermal Mass: 202 sqft Exposed Slab Floor, 3.50" thick at Bedroom's 2, 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 473 sqft Covered Slab Floor, 3.50" thick at Bedroom's 2, 3 The HVAC System "HVAC -4" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -4" has R-6.0 Heating Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -4" has R-6.0 Cooling Duct Insulation. Insulation levels above R-4.2 must be verified. The HVAC System "HVAC -4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 462 sqft Exposed Slab Floor, 3.50" thick at Guest House , HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC -4" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 12/29/03 11:10:55 Run Code: 1072725055 EnergyPro 3.1 By EnergySoft User Number: 3665 • Job Number: - Page: 17 of 47 Run Initiation Time: 12/29/03 11:10:55 Run Code: 1072725055 EnergyPro 3.1 By EnergySoft User Number: 3665 • Job Number: - Page: 17 of 47 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE La Bahn Residence 12/29/2003 SYSTEM NAME FLOOR AREA HVAC -1 1,305 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 79,000 Total Output (Btuh) 79,000 Output (Btuh/sqft) 60.5 Cooling System Output per System 60,000 Total Output (Btuh) 60,000 Total Output (Tons) 5.0 Total Output (Btuh/sqft) 46.0 Total Output (sgft/Tbn) 261.0 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 1.53 Airflow (cfmrron) 400.0 Outside Air (%) 3.9 Outside Air (cfm/sgft) 0.06 Note: values above given at ARI conditions 26.0 of ) ;0 Outside Air 78 cfm 69.3 OF 115.0 / 78.6 of Outside Air • 78 cfm 74.8/62.10F 3.1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,677 32,762 5,376 811 29,365 0 1,638 1,468 0 0 78 3,351 1,42 78 3,609 0 0 1,638 1,468 39,3:89F7;:;6 35,910 TRANE 2TTR2060A'/TUD100C960K 45,693 5,052 79,000 Total Adjusted System Output 45,693 5,052 79,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I I Jan 12 am n.- — -n- Heating Coil Supply Fan 2000 cfm 104.7 of Supply Air Ducts 104.0 OF ROOMS 70.0 of �% Return Air Ducts 76.3 / 62.9 of M 54.9 / 53.8 of User Number: 3665 Cooling Coil Supply Fa 2000 cfm 54.9 / 53.8 of � Supply Air Ducts Fan 55.6/54.1OF 50.7% R.H. ROOMS 74.0 / 61.9 of Return Air Ducts Job Number: 18 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE La Bahn Residence 12/29/2003 SYSTEM NAME FLOOR AREA HVAC -2 2,520 Number of Systems 2 Heating System Output per System 79,000 Total Output (Btuh) 158,000 Output (Btuh/sgft) 62.7 Cooling System Output per System 60,000 Total Output (Btuh) 120,000 Total Output (Tons) 10.0 Total Output (Btuh/sgft) 47.6 Total Output (sgft/Ton) 252.0 Air System CFM per System 2,000 Airflow (cfm) 4,000 Airflow (cfm/sgft) 1.59 Airflow (cfm/Ton) 400.0 Outside Air (%) 3.8 Outside Air (cfm/sgft) 0.06 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 OF 67.6 OF Outside Air 151 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I CFM I Sensible 4,019 77,043 11,723 1,714 62,044 0 3,852 3,102 0 0 15 6,448 2,652 151 6,963 0 0 3,8521 3,102 91 196 14,3751 75,211 TRANE 2TTR2060A•/TUD100C960K 90,838 10,975 158,000 Total Adjusted System Output go,838 10,975 158,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am tream Temperatures at Time of Heating Peak) 104.8 OF 104.8 OF O Supply Air Ducts Heating Coil Supply Fan 104.0 OF 4000 cfm ROOMS 69.3 OF 70.0 OF 115.0 / 78.6 OF >---V Outside Air 151 cfm 74.9/62.4 °F S (Airstream T 76.4 / 63.1 OF 11 h Return Air Ducts �1 ?ratures at Time of Cooling Peak) 55.1 / 54.0 OF 55.1 / 54.0 OF 0.: Supply Air Ducts Cooling Coil Supply Fan 56.0 / 54.4 °F 4000 cfm 51.4% R.H. ROOMS 74.0/62.1°F Return Air Ducts EnergvPro 3.1 By EnergvSoft User Number: 3665 Job Number: Paae:19 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE La Bahn Residence 12/29/2003 SYSTEM NAME FLOOR AREA HVAC -3 675 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 980 18,896 - 2,654 493 14,169 0 0 Supply Air Ducts 945 708 0 0 4 1,728 729 41 1,868 0 ROOMS 0 945 708 22,514T7773,383 ITRANE 2TTR2030A/TUD040C930K 1 22,8931 2.5231 Total Adjusted System Output 22 893 2,523 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm 17 454 32,000 32,000 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 67.6 of 97.6 of 97.6 of 0 Supply Air Ducts Outside Air 41 cfm := 97.0 of Heating Coil Supply Fan 1000 cfm ROOMS 70.0 OF 69.3 of Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 115.0/78:6 OF 76.5/63.0 OF 55.0/53.9 OF 55.0/53.9 OF Supply Air Ducts O Outside Air 41 cfm Cooling Coil Supply Fan 55.9 / 54.3 OF 1000 cfm ROOMS 50.9% R.H. 74.9/62.20F 74.0/61.9OF Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:20 of 47 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE La Bahn Residence 12/29/2003 SYSTEM NAME FLOOR AREA HVAC -4 462 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sqft) 138.5 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sqft) 51.9 Total Output (sgft/Ton) 231.0 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.73 Airflow (cfm/Ton) 400.0 Outside Air (%) 3.5 Outside Air (cfm/sqft) 0.06 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM Sensiblel Latent I CFM Sensible 733 14,500 1,932 183 14,049 0 725 702 0 0 28 1,184 526 28 1,274 0 0 725 702 17,133 2,458 16 728 TRANE 2TTR2024AITUD08OC924K 18,465 1,731 64,000 Total Adjusted System Output 18,465 1,731 64,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 67.7 of 142.9 of 142.9 of Supply Air Ducts Outside Air 28 cfm Heating Coil Supply Fan 142.0 of 800 cfm ROOMS 70.0 of 69.2 of I Return Air Ducts `iIt DOLING SYSTEM PSYCHROMETRICS (Airstream Temaeratures at Time of Coolina Peak) 115.0 / 78.6 of >----;ll Outside Air 28 cfm 1 74.9/61.9OF 76.2 / 62.6 of 54.6 / 53.5 of Cooling Coil Supply Fa 800 cfm 54.6 / 53.5 of Supply Air Ducts Fan 55.4/53 . 8 of 49.8% R.H. ROOMS 74.0 / 61.6 of h Return Air Ducts.',l EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:21 of 47 ROOM LOAD SUMMARY PROJECT NAME La Bahn Residence DATE 12/29/20.03 SYSTEM NAME HVAC -1 FLOOR AREA 1,305 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Master Suite Master Suite 1 1,677 32,762 5,376 1,677 32,762 5,376 811 29,365 PAGE TOTAL 1 1,677 32,762 5,376 811 29,365 TOTAL 1 1,677 32,762 5,376 811 29,365 EnergyPro 3.1 By EnergySoft f' User Number: 3665 Job Number: Pagel2 of 47 ROOM -LOAD SUMMARY PROJECT NAME La Bahn Residence DATE 12/29/2003 SYSTEM NAME HVAC -2 FLOOR AREA 2,520 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Living Zone Living Zone 1 4,019 77,043 11,723 4,019 77,043 11,723 1,714 62,044 t PAGE TOTAL 1 4,019 77,043 11,723 1,714 62,044 TOTAL 1 4,019 77,043 11,723 1,714 62,044 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 23 of 47 k ROOM LOAD SUMMARY PROJECT NAME La Bahn Residence DATE 12/29/2003 SYSTEM -NAME HVAC -3 FLOOR AREA 675 ROOM LOAD SUMMARY 4 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Bedroom's 2, 3 Bedroom's 2, 3 1 980 18,896 2,654 980 18,896 2,654 493 14,169 y. i s PAGE TOTAL 1 980 18,896 2,654 • 493 14,169 TOTAL 1 980 18,896 2,654 • 493 14,169 EnergyNo 3.1 By EnergySoft User Number: 3665 Job Number: Page: 24 of 47 ROOM LOAD SUMMARY PROJECT NAME LaBahn Residence DATE 12/29/2003 SYSTEM NAME HVAC -4 FLOOR AREA 462 ROOM LOAD SUMMARY, i ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Guest House Guest House 1 733 14,500 1,932 733 14,500 1,932 183 14,049 PAGE TOTAL TOTAL 1 733 14,500 1,932 183 14,049 1 733 14,500 1,932 183 14,049 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 25 of 47 A Project Title Date La Bahn ,Residence 112/29/2003 Room Information Design Conditions Room Name Master suite Time of Peak Jan 12 am Floor Area 1,305 Outdoor Dry Bulb Temperature 260F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr Items shown with an asterisk ('r) denote conduction through an interior surface to another room. 1305.0 X X X x X x x x X x x x x x x x x x X X x x. X x X x X- X X x x x x x x X x x x 0.0280 x x X X X x x x X X X x x x- x x x x X X X X X x X X X X x x x x) X x x x x x x 44.0 — = = = = _ = = _ _ = _ _ = = = = _ _ — = = — = = = = = = _ _ = _ = — = = 1,608 0 1,461.7 0.0592 44.0 3,808 221.3 0.3200 44.0 3,116 104.0 0.5500 44.0 2,517 perimeter = 169.0 29,365 44.5 7.520 Page:26 of 47 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: r Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 1 S 569 Infiltration: 1.00 x 1.064 x 1 305 x 10.60 x 1.00 / 60] x 0 = 10796 a Air Sensible Area Ceiling Height ACH � DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 29,365 Page:26 of 47 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Project Title Date La Bahn Residence 112/29/2003 Room Information Design Conditions Room Name Living zone Time of Peak Jan 12 am Floor Area 2,520 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 7001= R-38 Roof 8.38.2x14.16 R-21 Wall .21.2x6.16 A nders_on High Petformaace Anderson High Performance S-olid_V\Lood D, Slab -On -Grade . t 2,520.0 X X x x x X X x X X x X X X X X X X X X X X' X X X x x X X X X x X X X X X X X 0.0280 X X x x x x X x X X X X X X x X X X X X X X X X X X X X X X X x X X x x X X x 44.0 = = = = = = = = =, = = = = = = = = _ = = 3,105 2,193.7. 0.0592 44.0 5,715 655.3 0.3200 44.0 9,227 272.0 0.5500 44.0 6,582 24.0 0.3872 44.0 409 perimeter = 288.0 44.5 12,816 Items shown with an asterisk (`) denote conduction through an interior surface to another room. Page Total: 37 854 Infiltration: [ 1.00IX 1.064 x 2 520 x 12.30 x 1.00 / 6]„ x 44 = 24190 Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 62,044 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 27 of 47 Project Title Date La Bahn, Residence 112/29/2003 Room Information D6sicin Conditions. Room Name Bedroom's 2,3 Time of Peak Jan 12 am Floor Area 675 Outdoor DryBulb Temperature 260E Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value • AT of Btu/hr Items shown with an asterisk (t) denote conduction through an interior surface to another room.. Page. Total: 8,902 ,t �0ao0o] a =a • "Infiltration: 1.00 x 1.064 x 675 x 10.00 x 1.00 / 60 x 44 5 268 Schedule Air Sensible Area Ceiling Height ACH OT Fraction f , TOTAL HOURLY HEAT'LOSS FOR ROOM 14,169 t EnergyPro 3.1 By EhergySoft ` User Number: 3665 ' Job Number: Page: 28 of 47 675.0 X x X x x X x x x x X x X x X X x x x x x X x x x x x X x x X x x X X x X X X 0.0280 X x x X X X x x x x X, X X x X x x X X X X X X x x x x x X x x x x X x x x X X 44.0 = = = =. = = = _ = _ = = = = = _ = = = — _ _ _ = = 832 ` 550.0 0.0592 44.0 1,433 100.0 0.3200 44.0 1,408 80.0 0.5500 44.0 1,936 perimeter = 74.0 44.5 3.293 Items shown with an asterisk (t) denote conduction through an interior surface to another room.. Page. Total: 8,902 ,t �0ao0o] a =a • "Infiltration: 1.00 x 1.064 x 675 x 10.00 x 1.00 / 60 x 44 5 268 Schedule Air Sensible Area Ceiling Height ACH OT Fraction f , TOTAL HOURLY HEAT'LOSS FOR ROOM 14,169 t EnergyPro 3.1 By EhergySoft ` User Number: 3665 ' Job Number: Page: 28 of 47 Project Title Date La Bahn Residence 112/29/2003 Room Information Desicin Conditions Room Name Guest House Time of Peak Jan 12 am Floor Area' 462 Outdoor Dry Bulb Temperature 260F Indoor Dry Bulb Temperature 70 OF Anderson Hi h Performance Slab--Oj3--Grade Items shown with an asterisk M denote conduction through an inter 462.0 X X X x x. x X x X X x x x X X X X X X x x X X X X X X x X' X X x X, x X X X Xx X 0.0280 x x X X X X X x X X x X x x X X X x x X X X X x X X X x X X X - x X X X X X X 44.0 = = = = = = = = = = = = = = = — = = =• = _. = = = = = = = = — = = = = 569 884.8 0.0592 44.0 2,305 128.2 0.3200 44.0 1,805 24.0 0.5500 44.0 581 = 110.0 + 44.5 4,895 -perimeter r 'Schedule Air Sensible Area Ceiling Height ACH — DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,049 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number:. Page: 29 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY La Bahn Residence 12/29/2003 Project Title Date Room Name Master Suite Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction .21.2x6.1 Area U -Value X 1 0.02801 DETD 1 X 59.0 X 38.6 x 42.0 X 42.0 X X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC 119 - (North) 5 (East) 126 (East) 102 '(East) 103 (East) 104 (East) 109 B East (West) 101 B West est ( 0.0 X, x x x X X x x x 1 + + + + + + + + + + 80.0 x x x x x x x x x 15) x x x x x x 0.545 ( 0.0 1 20.0 73) 0.545 ( 0.0 1 20.0 73)X 0.545 ( 9.0 1 36.0 73) 0.545 ( 0.0 1 8.7 73) 0.545 ( 0.0 1 20.0 73)X 0.545 ( 0.0 1 20.0 73)X 0.545 ( 0.0 1 80.0 73) 0.545 ( 0.0X 1 7.6X 7)X 0.545 ( 23.7 1 0.3 73) 0.545 74°F 116°F 42°F Btu/hr 2,156 3,341 2,974 2,402 10 874 Btu/hr 655 796 796 1,507 346 796 796 3,186 = 303 206 Page Total 9,388 Sched. Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,305 x 0.000 Watts/sgft x 3.4d. Btuh/Watt = 0 Occupants 1.00 X 1,305 X 250 Btuh/occ. I 250 sgft/occ. = 1,305 Receptacle 1.00 x 1,305 x 0.200 Wafts/sqft x 3.413 BtuhMaft = 891 Process 1.00 x 1,305 x '0.000 Wafts/��sgft��x 3.41 BtuhMaft = 0 Infiltration: [ l)0 x 1 1.or,44 x 3m x 0_60 x 1 1.001 / 60] = 0.3Q5 Schedule Air Sensible Area Ceiling Height ACH nsT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM t 32,7621 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 305 x 200 Btuh/occ. / 250 sgft/oCC. = 1 044 Receptacle 1.00 x 1 305 x 0.000 Watts/sgft x 3.41 Btuh/Waft = 0 Process 1.00 x 1 305 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = 0 Infiltration: 1.00 x 4 77 x 1 30 x 10.60 x 1.00 / 60] 1 0.00394 = 4 332 "`ssschedule Air Latent Area Ceiling Height ACH Dyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5,376 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 30 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY La Bahn Residence 12/29/2003 Project Title Date . Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Living Zone 740F 116°F 42°F Conduction Area U -Value ,DETD' Btu/hr x x x x X X x X x x (North) 59.0 = 4,164 x D 38.6 = 5,014 x (North) 42.0 = 8,807 x 2 abv 42.0 = 6,283 X 0.545 38.6 = 359 1. Design Equivalent Temperature Difference (DETD) Page Total 24 626 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 127 (North) 0 (North) E North D North C (North) Q (North) A (North) 1abv (North) 2 abv (North) 3 abv North ( 0.0 x1 X x x x x1 x X x x + + + + +' + . + + +° + 9.2 X .X X X x' x x x X x 15) X ) x x x X ) X x 0.545 = = = = = = = = __ =1 75 ( 0.0 1 80.0 15 0.545 655 ( 0.0 1 40.0 15)X 0.545 327 ( 0.0 1 22.7 15) 0.545 '186 ( 0.0 1 22.7 15) 0.545 186 ( 0.0 22.7 15)X 0.545 186 ( 0.0 1 40.0 15) 0.545 327 ( 0.0 1 6.0 15)X 0.545 49 ( 0.0 1 6.0 1 0.545 49 ( 0.0 1 6.0 I 15) 1 0.545 49 Sched. Page Total 2 obs Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 2,520 X 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Occupants 1.00 X 2,520 X 250 Btuh/occ. / 250 sgft/occ. = 2,520 Receptacle 1.00 x 2,520 x 0.200 Watts/sqft x 3.413 Btuh[VVaft = 1,720 Process 1.00 X X�2,5200 x X0.00000 Wafts/sgft X 3.41�BtuhlWaft = 0 Infiltration: 1..Q0 x 06 x E1 520J x 1 12_�OJ x oo / 60] . L 42J _3,09 Schedule Air Sensible 'Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 77,0431 Sched. Latent Gain Frac. Area Heat Gain ' Btu/hr Occupants 1.00 X 2 520 x 200 Btuh/occ. / 250 sqft/occ. = 2 016 Rece tacle 1.00 x 2 520 x 0.000 Watts/sqft x 3.41 Btuh/Watt = o Process 1.00 X 2 520 x 0.000 Watts/sgft x 3.41 Btuh/Waft = 0 Infiltration: 1.00 x 4 77 x 2 52 x 12.30 x 1.00 / 60]. 0.00394 = 9 707 a Air Latent Area Ceiling Height ACH OW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 11,723 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 31 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY La Bahn Residence 12/29/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value DETD 1 Living Zone 740F 116°F 42°F Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr A (East) 108 (East) A _ East B (East) C (East) D (East) A B C East (East) (East) 113 East ( 0.0 X1 x x x x x x x X x + + + + + + + + + + 40.0 X x x X x X X x X x 73 )X x x X X ) x x 0.545 = = = = = = = = _ = 1,563 ( 0.0 1 18.0 73) 0.545 717 ( 0.0 1 20.0 73)X 0.545 796 ( 0.0 1 20.0 73)x 0.545 796 ( 0.0 ,1 20.0 73) 0.545 796 ( 0.0 1 20.0 73) 0.545 796 ( 0.0 1 24.0 73) 0.545 956 ( 0.0 1 48.0 73)X 0.545 1,911 ( 0.0 1 24.0 73 0.545 956 (1 0.0 1 18.0 I 73) 1 0.545 717 Sched. Page Total 10 035 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 2,520 x 0.000 Watts/sgft x 3.41 Btuh/Watt - 0 Occupants 1.00 X 2,520 X 250 Btuh/occ. / 250 sgft/occ. = 2,520 Receptacle 1.00 x 2,520 x 0.200 Watts/sgft X 3.413 Btuh/Watt = 1,720 Process 1.00 x 2,520 x 0.000 Wafts/�sgfttx 3.41 Btuh/Watt = 0 Infiltration: �x 1.os4 x 2,520 x x �1.90J / 60] = 3 Q9 Schedule Air Sensible Area Ceiling Height ACH L\T, Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 77,043 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 2 520 x 200 Btuh/OCC. / 250 sgft/occ. Receptacle 1.00 x 2 520 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process 1.00 x 2 520 x 0.000 Wafts/sqft x 3.41 Btuh/Waft = o Infiltration:�chedul�r° x Air Latent x Area 52 X Ceiling Height x ACH 00 / 60] 6.003941 = 9 707 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 11,723 EnergyPro 3.1 By EnergySoft User Number. 3665 , Job Number: Page: 32 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY La Bahn Residence 12/29/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value ' X DETD 1 Living Zone 74°F 116DF 42°F Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items'shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain . Orientation Area SGF Area SGF SC Btu/hr A (East) 1 (East) C D (East) (East) 4 abv (East) 5 abv (East) 6 abv East 106 (South) A (South) 107 South ( 0.0 X x X x X x x1 x x X 1 + + + + + +- + + + + 20.0 X X x X X X X X X X 73 ) X )x X X x 0.545 = = = = = = = = = = 796 ( 0.0 1 20.0 73 0.545 796 ( 0.0 - 1 20.0 73)X 0.545 796 ( 0.0 1 20.0 73)x 0.545 796 ( 0.0 1 6.0 73)x 0.545 239 ( 0.0 1 6.0 73) 0.545 239 ( 0.0 6.0 73) 0.545 239 ( 32.0 1 0.0 32)X 0.545 262 ( 40.0 1 0.0 32), 0.545 327 ( 32.0 1 0.0 32) 0.545 262 Sched. Page Total 4,753 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 2,520 X 0.000 Watts/sgft X 3.41 BtuhlWaft = 0 Occupants 1.00 X 2,520 _X 250 Btuh/occ. / 250 sgft/ocC: = 2,520 Receptacle 1.00 x 2,520 x 0.200 Watts/sgft x 3.413 Btuh/Waft = 1,720 Process 1.00 x 2,520 x 0.000 Wafts�/sgfttx 3.41 Btuh/Waft = 00 Infiltration: [ 1.pp x x ' 520 x X12 3DJ x I �_00J / 60] _ X23 0911 Schedule Air Sensible Area Ceiling Height ACH G\T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 77,043 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu ants1.x 2 520 X 200 Btuh/occ. / 250 sgft/oCC. = 2 016 .Receptacle [-::110001000 . x 2 520 X 0.000 Watts/sqft x 3.41 Btuh/Waft = 0 Process . x ` 2 520 x 0.000 Wafts/sgft x 3.41 BtuhlWatt = 0 Infiltration: 1.00 X L 4,77 X 2 52 X 12.30 X 1.00 / 60] 0.00394 = 9 707 chedule Air Latent Area Ceiling Height ACH ZW Fraction TOTAL HOURLY LATENT HEAT GAIN -FOR ROOM 11,723 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 33 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY - La Bahn Residence 12/29/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Living Zone 74°F 116°F 420F Conduction Area U -Value DETD 1 Btu/hr 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to "another room. Page Total 0 Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 7 abv South g -a (South) 128 (South) 9 abv (West) 10 abv (West) 105 (West) ? West 121 (West) B (West) C West ( 0.0 X1 x X x x x x x + + + + + + + + + + 6.0 X .x X X X 'x x x X x 32) X x x x ) x 0.545 = = = = = = = = = = 105 ( 0.0 1 6.0 32)x 0.545 105 ( 0.0 1 9.1 32) 0.545 159 ( 0.0x 1 6.0 73)x 0.545 239 ( 0.0 1 6.0 73) 0.545 239 ( 0.0 1 51.7 73) 0.545 2,059 ( 0.0 1 24.0 73)X 0.545 956 ( 0.0.x 1 18.0 73)X 0.545 717 ( 0.0 1 16.0 73)x 0.545 637 ( 0.0 1 40.0 73 0.545 1,593 Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 2,520 x 0.000'WattS/sgft X 3.413 Btuh/Watt = 0 Occupants 1.00 x 2,520 X 250 Btuh/occ. / 250 sqft/occ. = 2,520 Receptacle 1.00 x 2,520 x 0.200 Watts/sgft x 3.413 Btuh/Watt = 1,720 Process 1.00 x 2,520 x X0.000 Watt�s/sgft X 3.41 Btuh/Watt = 0 Infiltration: x I 1.oFi41 x 2 520 x E=27-3 x I =001 / 60] ,Q9� Schedule Air Sensible Area Ceiling Height ACH �T ' Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 77,0431 Sched. Latent Gain, Frac. Area Heat Gain Btu/hr Occu ants1.00 x 2 520 x 200 Btuh/OCC. / 250 sgft/occ. = 2 016 Receptacle 1.00 X 2 520 x 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Process 1.00 X 2 520 X 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Infiltration: 1.00 X 4 77 X 2 52 ' X 12.30 x 1:00 /601 0.00394 = 9 707 chedule Air Latent Area Ceiling Height ACH QW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 11,723 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 34 of 47 T RESIDENTIAL ROOM COOLING LOAD SUMMARY La Baffin Residence 12/29/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: .Living Zone 740F 116°F 42°F Conduction Area U -Value DETDBtu/hr X = X — X = X = X — X = X = X = X = 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr D (West) 0.0 x 1 + 16.0 x 73 ) X 0.545 = 637 1.2 (West) ( 0.0 x 1 + 8.7 x 73 ) x 0.545 = 346 124 (West) ( 0.0 x 1 + 10.5 x 73)X 0.545 418 ( X + X )X ( x + x )x — ( X + x)X = ( x + XH)X )X = ( x + X)X — ( x t + X = r • Sched. Page Total 1 ao2 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 2,520 X 0.000 Watts/sqft x 3.41 Btuh/Waft ' = 0 Occupants 1.00 X 2,520 X 250'Btuh/occ. / 250 sgft/occ. = 2,520 Receptacle 1.00 X 2,520 X 0.200 Watts/sgft x 3.413 Btuh/Watt = 1,720 Process 11.000x�x 2,520 x 0.0.000 Watts��/sgftt�x 3.41 Btuh/Waft = o ' Infiltration: ' oo x 1 1.0691 x x X12- xI 1 1.001 / 60] _3 0 Schedule Air Sensible Area Ceiling Height ACH Z—\T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 77,043 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 2 520 x 200 Btuh/occ. I 250 sgft/occ. = 2 016 Rece tacle 1.00 x 2 520 x 0.000 Wafts/sgft x 3.41 Btuh/Watt o Process- f' 1.00 X 2 520 x 0.000 Wafts/sqft X 3.41 BtuhMatt = 0 Infiltration: I 1.00 x 4 Latent x 2 52 x' Heigh x H, / 60] . 0.00394 9=707 chedule Air Latent Area • Ceiling Height ACH. ,. DW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 11,723 4 ` • EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 35 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY La Bahn Residence 12/29/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Bedroom's 2, 3 74°F 116°F 42DF Conduction Area U -Value DETD 1 Btu/hr X X X X X X. X x X X X X X X X X X X 59.0 = = = = = = = = = 1,115 38.6 1,257 42.0 1,344 42.0 1,848 E (West) F (West) 118 (West) ( 0.0 0.545 ( 20.0 1. Design Equivalent Temperature Difference (DETD) Page Total 5 564 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Solar Gain Orientation Area SGF 123 x x X x1 X x X x1 x X 1 _(West) (West) D (West) E (West) D (West) E (West) F (West) 118 (West) ( 0.0 0.545 ( 0.0 x x X x1 X x X x1 x X 1 + + + + + + + + + ( 0.0 1 ( 0.0 15,+ ( 0.0 0.545 (_0.0 1 ( 0.0 1 ( 0.0 1 ( 0.0 0.545 ( 20.0 ( 0.545 Unshaded Area x X x x x x x X X SGF ) X ) x x X )X SC = = = = = = = = Btu/hr 10.0 73 0.545 398 20.0 73 0.545 796 40.0 73)X 0.545 1,593 20.0 73) 0.545 796 20.0 73)x 0.545 796 40.0 73)X 0.545 1,593 20.0 73) 0.545 796 10.0 73)X 0.545 398 Sched. Page Total 71x8 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 z 675 x 0.000 Watts/sqft x 3.413 BtuhlWaft = 0 Occupants 1.00 X 675 X 250 Btuh/occ. / 250 sgft/occ. = 675 Receptacle 1.00 x 675 x 0.200 Watts/sqft X 3.413 Btuh/Waft = 461 . Process 1.00 x X�6755x 0.000 Watts/sgft X 3.41 BtuhlWaft = 0 Infiltration: �� x x L 67.5 x 1 �0oo x [=o / 60] = 5928 Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,8961 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 675 X 200 Btuh/occ. ,/ 250 sgft/occ. = 540 Receptacle 1.00 X 675 x 0.000 Watts/sgft x 3.41 BtuhlWaft = o Process 1.00 x 675 x 0.000 Watts/sgft X 3.41 BtuhlWaft = o Infiltration: 1.00 x 477 x 675 x 10.00 x 1.001/60] 0.00394 = 2114 chedule Air Latent Area Ceiling Height ACH Z -\W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,654 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 36 of 47 RESIDENTIAL ROOM COOLING LOAD SUMMARY La Bahn Residence 12/29/2003 Project Title Date • Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Guest House 74°F 116°F 42°F Conduction Area U -Value DETD' Btu/hr X X X X X X X X X 59.0 = = = = = = = = = 763 38.6 2,022 42.0 1,723 42.0 554 110 West) - A (West) ( 0.0 ). 22.5 73) 0.545 ( 0.0 1. Design, Equivalent Temperature Difference (DETD) Page Total 5 063 Items showndw h an asterisk (') denote conduction through an interior surface to another room. Shaded Unsliaded Solar Gain Orientation Area SGF Area SGF SC 111 115 (East) (East) 114 East 129 (East) 11? (South) 130. (West) 110 West) - A (West) ( 0.0 1 22.5 73) ( 0.0 X1 x x x X X x x x + + + + + + + + + +, 7.5 X x X x x x x x x x 73 )X )x X x x X )X ) x 0.545 ( 0.0 1 22.5 73 0.545 ( 0.0 1 22.5 73) 0.545 ( 0.0 1 9.1 73) 0.545 ( 0.0 1 50.0 32) 0.545 ( 0.0 1 9.1 73)X 0.545 ( 0.0 1 7.5 73) 0.545 ( 0.0 1 24.0 73)X 0.545 ( (-x Btu/hr 299 896 896 362 873 362 299 956 Sched.` Page Total a 9a2 Internal Gain 'Frac. Area Heat Gain Btu/hr Li hts' 1.00 X 462 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Occupants 1.00 X 462 X 250 Btuh/OCC. / 250 sgft/occ. = 462 Receptacle 1.00 x 462 X 0.200 Watts/sgft x 3.413 Btuh[Watt = 315 Process 1.00 x 462 x X0.000 Watts/sgft x 3.412 Btuh/Watt = 0 Infiltration: Lp0 x 1.064 x x E::1_ol.�00xQo / 60] Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,5001 Sched. Latent.Gain Frac. Area Heat Gain Btu/hr Occupants - 1.00 x 462 x 2001 Btuh/occ. / 250 sgft/occ. : = 370 Receptacle 1.00 x 462 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process f 1.00 x 462 x 0.000 Watts/sqft x 3.41 Btuh/Watt = o Infiltration: I 1.00 x 4 77 x 46 x 10.80 x 1.00 / 60] 0.00394 = 1 563 -Schedule Air Latent Area Ceiling Height ACH Z -\W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,932 EnergyPro 3.1 By Energysoft User Number: 3665 Job Number: Page: 37 of 47