Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2005-605 (AR)
-tyr �O t .. . P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 OF 78-495 CAiLE TAMFICO •(760) 777-7000 LA QOINTA, CALIFORNIA 92253 • FAX (760)- 777-7101 February 14, 2005 i Weiskopf Partners, I, LLC ^ 78-150 Calle Tampico #101 La Quinta; ,CA 92252 SUBJECT: Approval for Minor -Use Permit 2005-605 Dear Applicant: Your request for Minor ,Use,Permit.•2005-605 to allow the construction for a . new :custom guest `casita at 57-750 Troon . Way is hereby approved. Enclosed is the-approved original Deed Restriction for this'Minor Use Permit. It must be signed by property owner in front of a :Notary Public. The original `w approved documents are then.to be `recorded with the County Recorder with a recorded copy, given to us for ,our files. Until, the -recorded copy is received, your Minor Use Permit is not complete. After we.review our copy, we will provide _ our clearance to the Building Departmentto issue .the r building permit. Should you have any ,questions please call me at (760) 777-7070. Very truly' yours, , TIM .N.GUYEN Assistant Planner Attachment c:—--Buildin-g=acrd-Safety=Departmen/t p:\mup LA 2005-605.doc RECORDING REQUESTED BY: Weiskopf Partners I,.LL.0 . 78-150.0 aIle. Tampico La Quinta, CA 92253 WHEN RECORDED PLEASE MAIL TO: Weiskopf Partners 1 LLC 78-150 Calle Tampico La Quinta, CA 92253 COVENANT AND AGREEMENT RESTRICTING THE USE OF. THE RESIDENCE AT 57-750 TROON WAY, LA QUINTA, CALIFORNIA This Covenant and Agreement are made. and executed this 10' day of February, 2005 by Weiskopf Partners I, LLC, as the recorded . owner(s) of: , the property described herein. The City of La Quinta, a Municipal Corporation, is hereby made a party to this Agreement for the purposes set forth below. The undersigned hereby. certifies that he/she is the property owner -of the following. described real property in the. City of La Quinta, County .of Riverside, - State of California: LOT 21, BK. 762 PG. 33, TR 29147-1, in the City of La Quinta,,County of Riverside, State of California. In consideration of the City of.La Quinta issuing a building permit for certain improvements which will be constructed on said property, the undersigned does hereby covenant and ' agree .to, and with said. City, to restrict the use ..of said property as follows:. 1.` - The guest house may not be rented nor sold independent of the main single-. family residence, (Minor Use Permit No. 2005-605); 2. No kitchen or cooking facilities shall be constructed in the guest house per the provisions of Chapter 9..30.030 (RL Zone District) and -'9.60.1.10 (Guest Houses) of the La Quinta Municipal Code; 3. All on-site facilities are intended for` the sole occupancy of the property owner(s); guests, and caretakers (i.e., a maid and/or housekeeper,'etc.); and, 4. The guest .house shall be. used primarily as a sleeping facility, and shall be maintained in accordance with all 'zoning and other codes as set forth in the a La Quinta Municipal Code, as may be. amended from time to time. This Covenant and Agreement shall run with the land and. shall -be. binding . upon future owners, their successors, heirs, or- 'assigns, and ourselves, and shall continue. in .effect while said accessory building remains on the real property 'or unless. otherwise released by the authority of the City of. La Quinta. , All leases of said dwelling and/or property shall be subject to this restriction, This Agreement A shall be entitled to the.remedy 'of injunctive relief in addition of any remedy in law or equity. This :Covenant. and Agreement and- the provisions hereof are irrevocable," except -,by the 'written consent of all parties to the agreement,: including the City of La Quinta, a Municipal Corporation. The City shall have the right to enforce each and every provision hereof and the parties 'agree that the Agreement shall not be rescinded, revoked, modified,, or otherwise amended or changed,. without ;the expressed written consent of the City first being obtained.." In the event that the owners, their heirs, assigns or, successors in interest, shall fail: to perform any. obligation hereunder; they hereby agree to pay all costs and expenses incurred by the 'City of La Quinta in securing performance of such obligation, including attorney's fees. By: ^ .'1 2. r,Z_ 3.. Signature(s) „Printed Name of all'owner(s) Dated: X Douglas R. Evans . Date' Community Development Director r City of La Quinta ALL PURPOSE -NOTARY ACKNOWLEDGMENT(S) MUST BE ATTACHED IN 8 1/2 X 11 " FORMAT, FOR EACH SIGNATURE. TITLE 24 REPORT y Title 24 Report for: The Summit Lot 3.1 - Cabana La Quinta; CA Project Designer: P t w Report'Prepared By: F Joan D. Hacker Insu=Form Inc. 68255 Corta Road j Cathedral' City, CA 92234' (760) 324-0216 CITY OF LA QU BUILDING & SAFffiT ber: APPP VED i FOR CONST TION b�. DA BY ; 11/15/2004 r The EnergyPro computer program has been used'toperform the calculations summarized in this compliance report. -This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: User Number 2655 Certificate Of Compliance: Residential '(Part 1 of 2) CF -1 R The Summit Orientation 11/15/2004 Project Title Fenestration Date Lot 31 - Cabana La Quinta Project Address SF Building Permit # Insu-Form Inc. (760) 324-0216 Plan Check / Date Documentation Author Telephone Front Computer Performance ' 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION X❑ ❑ ❑ X❑ Total Conditioned Floor Area: 786 fl? Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 786 ft2 0.44 Building Type: X❑ ❑ ❑ X❑ (check one or more) (Southwest) 48.0 © Single Family Detached ❑ Addition Bug Screen ❑ Single Family Attached ❑ Existing Building Right ❑ Multi -Family ❑ Existing Plus Addition. 0.57 Front Orientation: (Northwest) 315 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 G Number of Stories: 1 ❑ Raised Floor Component Const. Frame Assembly Slab On Grade n/a 0.756 R-19 Wall (W.19.2x6.16) Wood 0.065 R-30 Roof (R.30.202.16) Wood 0.035 Location/Comments (attic, garage, typical, etc.) Covered Slab w/R-0.0 Perimeter Insulation Exterior Wall Exterior Roof FENESTRATION Shadinn Dpvicps Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (Northwest) 94.0 0.57 0.38 Bug Screen X❑ ❑ ❑ X❑ Rear (Southeast) 60.0 0.62 0.44 Bug Screen X❑ ❑ ❑ X❑ Right (Southwest) 48.0 0.55. 0.53 Bug Screen X❑ ❑ ❑- X❑ Right (Southwest) 30.0 0.57 0.38 Bug Screen X❑ ❑ ❑ EX I El El El F-1 1-1 1-1 El ❑❑ ❑❑, ❑❑.❑❑ ❑❑ ❑❑ ❑❑ El F] Run Initiation Time: 11/15/04 10:12:20 Run Code: 1100542340 Ener Pro 3.1 By Ener Soft User Number: 2655 Job Number: Pa e:3 of 13 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R The Summit 11/15/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments C:Pntral Furnace 80% AFUE Ducts in Attic 4-2 Setback Casita Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct heat pump, evap. cooling)' (SEER) (attic, etc.) R -Value Thermostat Location/ Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 49 Sethack Cacita WATER HEATING SYSTEMS Rated 1 Tank Energy Facts . 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A O SMITH PGCG-50-246 Small Gas Pine Insulation 40-000 SO 0-62 � n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE 5TATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Joan D. Hacker Title/Firm: Title/Firm: Insu-Form Inc. Address: Address: .68255 Corta Road Cathedral City, CA 92234 Telephone: Telephone: (760) 324-0216 LIC. #: r ) date) (sig aturment Agency Nam Title/Firm: Address: Telephone: LEnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: PageA of 13 1 Certificate of Compliance: Residential (Addendum) CF=1 R The Summit 11/15/2004. ' Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local ; enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3ased on the adequacy of the special justification and documentation submitted. HERS Required Verification • These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS Plan' Field I proviaer. i ne rn:rca racer must aocumem me nein vermcauon ana oiagnosuc testmg or mese measures on a TOMI _GF -R. plan Field The HVAC System "Casita" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV; or measure the Refrigerant Charge and Airflow. The HVAC System "Casita" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. ' RunJnitiation Time: 11/15/0410:12:20 Run Code: 1100542340 EnergyPro 3.1 By EnergySoff User Number: 2655 Job Number: Page:5 of 13 Mandatory Measures Checklist: Residential (Page 1 'of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (7 may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures . whether they are shown elsewhere in the documents or on this checklist only. (DESCRIPTION instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures -§150(.): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturers labeled R -Value: • §1'50(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does . not apply to exterior mass walls). ❑'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ❑ §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ' 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑§150(1): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission._ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 13 ,Y o it Mandatory Measures Checklist''Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliancerequirements listed on the Certificate of Compliance: When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION. Instructions: Check or initial applicable boxes or enter N/A if not applicable: DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) F' 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system . that meets'the applicable requirements of UL181, UL181A, or UL1818. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or fie IAble duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be i compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems`and, their components shall not be sealed with cloth back rubber adhesive ' duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually , operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable ; for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam y insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance , heating, and no pilot. 2. System is installed with at least 36" of, pipe between filter and heater for future solar, cover for outdoor pools or spa's. v a. At least 36" of pipe between filter and heater for future solar heating. ' b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. ❑r §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ' I §150(k)l : Luminaires for.general lighting in kitchens shall have lamps with an efficacy 40 Iumenst att or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. El§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumenstwatt or greater switched at the entrance to the room or one of the aftemative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved., Computer Method Summary, (Part 1 of 3) C -2R The Summit Project Title 11/1 smu Date I ot 31 - C nhann I a_QI III1ta .Project Address Building Permit # Instl-Form Inr (760) 324-0216 Documentation Author Telephone plan Check/Date Comptiter Performance. Compliance Method (Package or Computer) 15 Climate Zone 1 Field Check/Date Source Energy Use Standard Proposed:' Compliance (kBtulsf-yr) Design Design Margin Space Heating 2.43 3.26 -0.83 Space Cooling 49.72 54.70 -4.97 Domestic Hot Water 9568 19 84 5 83 Totals 77.83 77.80 0.03 Percent better than Standard: 0.0% Total Conditioned Floor Area: 786 ft2 Building Type: Single Fam Detached Building Front Orientation: (Northwest) 315 deg Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING ZONE INFORMATION Zone Name Floor Construction Type: ❑ Raised Floor X❑. Slab Floor Total Fenestration Area: 29.5% Total Conditioned Volume: 7,860 ft 3 Total Conditioned Slab Area: 786 ft 2 # of Floor Area Volume Units, Zone Type 786 78S 1 on rnnditionPd Solar OPAQUE SURFACES Act Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Wall 516 0.065 315 90 ®ElR-19 Wall (V JEW 16) � Wall 190 0 065 45 0 ® ❑ R-19 Wall ON 19 2x6 16) Walt 540 0 065 '135 g0 ® ❑ R-19 Wall (W 192x6 16) Wall 112 0.065 225 gQ X R-19 Wall QN.19.2x6.16) Rnnf 786 0.035 315 _0 ® ❑ R-30 Roof (R_302x12-16) Thermostat Vent Type Hgt: Area RMhark _� n/a Location / Comments Run Initiation Time: 11/15/0410:12:20 Run Code: 1100542340 EnergyPro 31 By EnergySoft User Number: 2655 Job Number. Paoe:8 of 13 Computer Method Summary Screen 0.76 6.0 (Part 2 of 3) C -2R 2 Bug Screen 0.76 6.0 5.0 The Summit Screen 0.76 6.0 2.4 4 Bug 11/15/2004 Project Title 6 0 3.0 5 Bug Screen 0.76 Date FENESTRATION SURFACES 6 Bug Screen 0.76 8.0 6.0 7 Bug Screen 0.76, U- 5.0 Act. Glazing Type Location/ # Type Area Factor SHGC Azm, Tilt Comments , �L Windnw Front(Northwest) 140 0 570 038 315 90 Better Ruilt Windows Casita 2 Window Front (Northwest) 30.0 0.570 0.38 315 90 Better Built Windows Casita 3 Window Front (Northwest) 14.0 0.570 0.38 315 90 Better Built Windows Casita 4 Window Front (Northwest) 36.0 0.570 0.38 315 90 Better Built Windows Casita 5 Window Rear (Southeast) 60.0 0.620 0.44 135 90 Better Built Windows Casita 6 Window .Right (Southwest) 48.0 0.550 0.53 225 90 Better Built Windows Casita Z Window Right (Southwest) 30.0 0.570 0.38 225 90 Better Built Windows Casita INTERIOR AND EXTERIOR SHADING - Window # Exterior Shade Twe SHGC Hgt. Wd. 1 Bug Screen 0.76 6.0 2.4 2 Bug Screen 0.76 6.0 5.0 3 Bug Screen 0.76 6.0 2.4 4 Bug Screen 0.76 6 0 3.0 5 Bug Screen 0.76 10.0 6.0 6 Bug Screen 0.76 8.0 6.0 7 Bug Screen 0.76, 6.0 5.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 . 2.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 8.0 0.1 8.0 8.0 2.0 0.1 2.0 2.0 Left Fin Right Fin Dist. - Len. Hgt. Dist. Len. H Run ifa io Time: 11/16/04 0.12:20 Run Coe: 1100542340 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:9 of 13 Computer Method Summary (Part 3 of 3) C -2R The Summit 11/15/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments. PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 18 0.76 0-0 _0 . Casita Slab Perimeter 72 0.76 00 _0 Casita HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location/ pump, etc.) (AFUE/HSPFXducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Casita Pipe Insul. Hydronic Piping pipe System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct. Thermostat Location/ heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Shit Air Conditioner 12-0 SEER Ducts in Attic 4.2 Setback Casita WATER HEATING SYSTEMS Ratedl Tank Energy Factl 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A O SMITH PGCG-50-246 Small Gas Pine Insulation 1 1 40,000 50 0.62 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. RFMARKR Run Initiation Time: 11/15/04 10:12:20 Run Code: 1100542340 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 10 of 13 Computer Method Summary(Addendum) C=2R The Summit .11115/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3asea on ine aaequacy or ine special jusuncaaon ana oocumentanon suornmeo.. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS proviaer. i ne ntKJ rater must aocument ine nein vermcation ana oiagnosuc testing or tnese measures on a rorm GFR. Plan Field The HVAC System "Casita" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Casita" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation, Time: 11/15/0410:12:20 Run Code: 1100542340 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Pagel1 of 13 [HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Summit 11/15/2004 SYSTEM NAME FLOOR AREA Casita 786 ENGINEERING CHECKS SYSTEM LOAD (Number of Systems I 1I Heating System Output per System 74,000 Total Output (Btuh) 74,000 Output (Btuh/sqft) 94.1 Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sqft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions 26.0 OF Outside Air 0 cfm 69.4 of 11.0/77.40F Outside Air 0 cfm 69.4°F 6.9.4 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan 0,000 Ventilation 0,000 Supply Fan 3.3 Supply Air Ducts 50.9 TOTAL SYSTEM LOAD 235.8 HVAC EQUIPMENT SELF 1 395 COIL COOLING PEAK COIL HTG. PEAK CFM JSensible Latent CFM Sensible 1,162 20,115 1,874 367 18,980 0 1,006 949 0 0 0 0 0 0 0 o o 1,006 949 22,1261 1,8741 20 878 1,395 BDP CO. 563AN042-A 26,160 10,281 74,000 1.77 418.5 Total Adjusted System Output 26,160 10,281 74,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 m ,tan 12 am am Temperatures at Time of Heating Peak 118.8°F Supply Fan Heating Coil 1395 cfm Supply Air Ducts 118.2°F i ROOMS 70.0 of Return Air Ducts ! 78.7/66.3OF 78.7/66.2OF 61.2/60.1OF Supply Air Ducts Supply Fan Cooling Coil 61.9 / 660..3 OF 1395 cfm 53.7% R.H. ROOMS 78.7/66.30F 78.0/66.1°F' Retum Air Ducts EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:12 of 13 BROOM LOAD SUMMARY PROJECT NAME DATE The Summit 11/1.5/2004 SYSTEM NAME FLOOR AREA Casita 786 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Casita Casita 1 1162 20,115 1,874 1,162 20,115 1,874 36718,980 PAGE TOTAL 1 1,162 20,1151- 1,874 TOTAL° 1 1,162 20,115 1,874 367 18,980 367 18,980 EnergyPro 3.1 By EnergySofl User Number: 2655 Job Number: Page: 13 of 13 I Ce ( Hart 1 of 2) 'CF -1 R 11/14/2002 Dace Foundation Energy Buik D°aumet>ton Author - (949) 348-2414 COm uter Performance retephorre plan Compliance iNethod(Pac[cage or Computer) 1 I Field GENERAL INFORMATION Climate Zone Enfor Total Conditioned Floor Area: 4,744 ft2` Total Conditioned Slab Area: Average Ceiling Height: 4,744 ft2 Building Type: 0 756 (check one or more) Solid Wood Door tt��, tom; Single Family Detached 77 Addition -2, Single Family Attached f= Existing Building Multi -Family i_ Existing Plus Addition Front Orientation: (Northwest)' 315 deg Floor Construction Type: Number of Dwelling Units: X '1.00 ' Slab Floor Number of Stories: Raised Floor BUILDINGSHELL INSULATION (Soulheast) 'Component �Fype Frame Const: Assembly ; Location/Comments " Slab On Grade TYPe U -Value (attic garage, typical etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation i i R-19 WaB Na 0 756 Exposed Slab w/R-00 Perimeter Insulabon 1 Solid Wood Door Waod 0.061 Exterior Wall i R-38 Roof Wood 0.387 Exterior Door ! D Wood 0-028 Exterior Roof ! i i FENESTRATION (Soulheast) i ! i_ - 0.52 Bun Screen _ Shading Devices ype mentation Area (SF) Fenestration Exterior Overhang Side Fins U -Factor SH GC Shading Yes / No Yes,/ No ; Rear (South) . 80.0 0.62 0.52 _ Bug Screen 1xi ! D ,I_I !` j Rear (Soulheast) r 160.00.62 0.52 Bun Screen _ XI i__I ! j IX I Rear (Southeast)- 175.0 1.19 0.72_ Bug Screen L i D` EXI Rear (Southeast) 199.0 0.59 0.58 Bug Screen Right (Southwest) 98.0 , 1.19 0-72 Bug Screen Y ' X i L r t. �`.! Right (Southwest) 74.0 0.77 0.36 _ + Bua Screen j (; u ' 3 -_i r i !X; Front (Northwest) 16.5 1.19 0-72 _ t3ug Screen !X r Front (Northwest), 40.0 Q55 0.65uqScreen S Lett (Northeast) 92.0 1.19 0.72 Bug Screen" j j 'X ! Right (Southwest) 70.0 0.55 0.65 Sun S&eeni,EXIii; iX I Right (Southwest) 8.0 0.59 0.58 Bun Screen lZ E] • ''-1 Front (Northwest) 26.0 :r 0.72 _ 0.73 Bug Screen ' " - _ EnergyPro 3.1 By EnergySoft User Number: 3412 Job Number: MTZPGAW2 - . Page: f of 11 Certsificata n �AIrie1�e� Project Tit(e – • ••" 'ar r co iv V V I 11/14/2002. La Uinta CA Date pn�lect Address Foundation Energy' Documentation Author j Building Permit # (949)- 34$-2414 Computer -Performance phone I Ptah Ch Teleeck J Date i 15 compliance Method (Package or Computer) . Field Ca heck / D le GENERAL'INFORMATIO'N Climate Zone Enforceayent Agency Use Only Total Conditioned Floor Area: 4,744 ft2 Total Conditioned Slab Area: Average Ceiling Height: 11.1 ft 4, 744 ft2 Building Type: ` (check one or more) Yes / No Single Family Detached i—i ,Addition Single Family Attached " LJ Existing Building Multi -Family i. Existing Plus Addition Front Orientation: (Northwest) Number of Dwelling Units: 315 deg Floor Construction Type: jX l! ;Slab Floor v Leff Left 1 0tJ Number of Stories:' r i 0.65 _ j ! Raised Floor . BUILDING SHELL INSULATION i� i7 Component 1.Type i j i I Const. Frame Assembly Type U -Value � I WT. CLIe ^ —..... . x Location/Comments 1__114=0 r LM I IV Shading Devices Type Orientation Area (SF) Fenestration Exterior Overhang Side Fins U -Fa or SHG(' Shadino Yes / No Yes / No Front (Northwest) 36.0 0.1-7 0.36 Bua Screen �X;i '�—i Leff Left (Northeast) 76.0 0.55 0.65 _ Bust Screen (`X I? i� i7 (Northeast) 49.5 0.59 0.55 _ Bun Screen r I IJ Left fNortheast) 10.0 0.72 0.73 _ Bug Screen `J x' ( J r IX Left (Northeast) 30.0 0.77 0.36- Bug screen `J EK "I -- — i iX Skylight 9.0 0.80 0.57 None._ LJ LJ u _l j LJ v LJ ! Run Initiabm Time: 11/14/02 07.48-43 Run Code: 1037288923 EnergyP- 3.1 By EnergySoft User Number: 3412 y Job Number: MTZPGAW2 Page:2 of 1 V Certificate of ngmpliance- Residential HVAC SYSTEMS Heating Equipment Type (furnace, heat Pump, etc.) 2 0_ f 2) CF -1 R 11/14/2002 Date Nobe Input Hydropic Or Cotnb(ned Hydronlc data under Water Neaung Systems, except Design Heating Lead. Minimum Distribution Efficient Type and Duct or _ _ Y Location Pi in tmi Central Face 80'—E Central Eiimar _ 80-E Cooling Equipment Minimum Type (air conditioner, Efficiency heat pump, evap, cooling) (SEER) Split Air Conditioner -12.0 SEER SolitAicCooditionar WATER HEATING SYSTEMS )(ducts, attic, etc.) R Pi Type Location / YP Comments Duefs in •Attic Ducts in Asti �� �— a— r-`�— — A-nLIVING HVAC ` S thark SI EEP�ti �jAC Duct Location Duct Thermostat Location /. (attic, etc.) R -Value Type Comments Ducts in Attic — Q — Setha_ rk LIVINr, iA Du _ in Att_ 'r`___ 6 � Sethaa SLEEPING HVAC --------------- Water Heater Rated 1 Tank Energy Factl External Water Heater Distribution # in Input Cap. or Recovery Standbys Tank Insul. System Name Type Type Syst. Btu/hr A O SMITH FPr`o �n Small as (gal) Efficiency Loss (%) R -Value 23 --=L_ Recirm +T mo i_ Opp �Q __4_65 R g SMITH FPCR-50- Small Gas nta n/a �_ Recir�me+Temo 1 _qg� � 0 � _ Na Na 1 For small gas storage (iated inputs of hms gt n or equal 14 75.000 Btuihr), electric resistance and heat For targe gas storage water heaters (rated input of greater than 75,000 f3tWhr), dist Raced Input, R� Pump water heaters. list energy factor. For instantaneous gas Water heaters. Fist Rated Input and Recovery Efficiency.. Y Efficiency and Standby loss. REMARKS Sren oor ass ca c ate Per - o est en6a C - ass P ming. calculation is for Base Plan 28 oriented to Northwest COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to ca California Code of Regulations, and the administrative rementthem.This cocate mply withn signed Title 24, Parts 1 and 8 of the overall design responsibility. The undersigned recognize that ccompliancelusi g duct sealing andfiTXV's requires Installer testtng and certification and field verification by an approved HERS rater. Designer or Owner (per Business & professions Code) Documentation Author Name: Title/Firm: Southern His Development, Inc. Name: Benito Ramirez Address: 55161 south— Hlis Title/Firm: Foundation Energy Address: 27525 Puerta Real 1103 Mission Vlejo, CA 92691 Telephone: (949) 348-2414 (signature) (date) 3.1 By EnergySon User Number: 3412 - - ,-- lob Plumber MTZPGAW2 3of11' I La Quinta, CA 92253 Telephone: 760-771-1761 (signature) Z Enforce t Agency (date) Name: Title/Firm: Address: Telephone: Address: 27525 Puerta Real 1103 Mission Vlejo, CA 92691 Telephone: (949) 348-2414 (signature) (date) 3.1 By EnergySon User Number: 3412 - - ,-- lob Plumber MTZPGAW2 3of11' n • { '.'Certificate of COM .liance: Residential r� Addendum CF -1 R', The Summit at PGA West -Plan 2B N 4 Protect Tate I 11 /14/2002 I ' Special Features and Modeling Assumptions Date The focal enforcement agency should pay special attention to the items s ' ',vridten justification and docunreMation ands in this checklist. These items require special enforcement agency determines the adequacy off � verification to be used with the performance approach. The local based on the adequacy of the special justification and documentation' and may reject a building or design that otherwise complies submitted. The HVAC System "LIVING HVAC" must meet all CEC Criteria for a Zonally Controlled system serving only Lwin Areas. 'Plait Field ! jThe HVAC System "LIVING HVAC" has R-6.0 Heating Duct Insulation. Insulation levels above R 42 must be verified. 1 The HVAC System "UVWG HVAC - I— has R�.O C ! A °oling Duct Insulation. Insulation levels above R-4.2 must be verified. j he HVAC System "WING HVAC" includes credit foraRadiant Barrier installed per Section 8.13 of the Residential Manual. i ' NIGH SS MASS Desi ) e* Thermal Mass: 293 sgft Covered Slab Floor, 3.50" thick at Living Areas [ gn(see C -2R - V t HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1904 s qft Exposed Slab Floor, 3.50",thick at Living Areas I ' The HVAC em "SLEEPING HVAC" must meet an CEC Criteria for a Zonally Controlled system serving only Sleepin ens.. 1 Q ; !The HVAC System "SLEEPING HVAC" has R.O Heating Dud Insulation. insulationtevels above R-4.2must be verified. i The HVAC System "SLEEPING HVAC' has R-6.0 Co oGr�g Duct Insulation. insulation levels above R-42 must be verified. i I The HVAC System "SLEEPING HVAC" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. !HIGH MASS Design(see- C -2R) - Verify Thermal Mass: 1929 sgft Covered Slab Floor, 3.50" thick at Sleeping Areas i I J HIGH MASS Design(see C 2R) - Verify Thermal Masa: 618 sqR Exposed Slab Floor, 3.50" thick at Ste i eping Areas HERS Required Verification ^ These features must be confirmed andfor bested by a certified HERS rater anklet the supervision of a CEC approved HERS provider. The HERS rater must document the field verrTication and d' r tl diagnostic besting of these measures on a form CF -6R. Plan (Field i The HVAC System "LMNG HVAC" includes Refigerant Charge and Airfbw Creditor a ( T)V). A certified HERS rater must provide ! ' �verffrfication of the TXV, or measure the Refrigerant Charge and Airflow. z i The HVAC g 1 i System "LIVING fiVAC" is using reduced duct leakage to complyand must have diagnostic site testing of duct leakage ! performed by a certified HERS Rater. The results of the drapnostic tegtina must be renorted on a CF -6R Form. IThe HVAC S ! ! ystem "SLEEPING HVAC' includes Refrigerard Charge and Airflow Credit (or a TXV). A certified HERS rater must i j provide verifification of the TXV, or measure the Refrigerant Charge and Airflow_ I The HVAC System "SLEEPING HVAC" is usingreduced dud leaks to cos - 1 ! ! , leakage ply and must have diagnostic site testing of duct leakage 1 i • i performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. i I ! e. Run Initiation Time: 11/1410 07:48: -Run Code: 1037 923 EnergyPro 3.1 By EnergySofr User Plumber: 3412 Job Number. MTZPGA' 2 Page: 4 of 11 , Mandatory Measures Checklist: idential (Page 1 of 21 NOTE:MF-1 fq Lowrise residential barikfngs subject to the Standards must contain these',measures asterisk (•) may be regardless of the compliance approach used. ttems marked with an Y superseded by more sfxingent compliance r�irements listed on the Certificate of Com the permit documents. the features noted shall be omsidered b ell pliance..Whera this dteckGst is incorporated into whether they are shown Y Parties as minimum component perfomtance specfications for the mandatory measures elsewhere in the documents or on this checklist only. I i !DESCRIPTION In structions: •Check or initial applicable bdxes or enter N/A if not applicable. DESIGNER i ENFORCEMENT I Building Envelope measures j D : �§ 150(a): Minimum R-19 ceiling insulation. i 11 E §150(b): Loose Q k'S tatKM manufacturer's labeled R -Value_ ' i Minimum R-13 wall insulation lls lation in wood framed waft or not apply to exterior mass walls). equ--ftr t U -value innetal traria vralis (does ! §150(d): Minimum R-13 raised floor insulation in framed floors or equivalent , Slab edge insulation - water absorpdon L— greater than 20 perrrafuach, rate no greater than 0.3%, water vapor transmission rate no 1 J § 118: Uisulation specified or installed meets insulation quality surds. indicate type and fora_ (� § 116-17: Fenestration Products. Exterior Doors and tnfilhation/Ex1iltration ;Controls . 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration Products (except field fabriceted) have label with certifiedU-Factor. certified Solar Heat Gain Coefficient (SHGC). and infiltration certification. 3. Exterior doors and windows vmathsrsh*ped: all joints and Penetration caulked and sealed. § 150(9): Vapor barriers mandatory in Climate Zones 14 and 16 only. Special infiltration barrier installed to comply with. Section 151 meets Commission Xquality standards. X§ 150(e): installation of Replaces, Decorativa Gas Appliances and Gas Logs. i 1. Masonry and factory fireplaces have. j a. Closeable metal or glass door b. Outside air intake with damper and control ! c. Flue damper and control 2 No continuous barring gas pilots allowed I Space'Conditioning, Water. Heating and Plumbing' System Measuri xl! §11G-13: HVAC equipment water healers, showerheads and faucets certified by the Commission. ! §150(h): Heating andlor cooling toads calculated in accordance with ASHRAE. SMACNA or ACCA. X! § 150(i): Setback thermostat on all applicable heating and/or cooling systems. J§150(j): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank non -recirculating sysberns, insulated (R-4 or greater) 3. Back-up tanks for solar system. unfired storage tanks. or other indirect hot wales tanks have R-12 external insulation or R-16 combined inter a exlemal insulation_ i 4. All bairied or exposed Piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between hrating source and indirect hot water tank. 3.1 By EnergySoit User Number. 3412 —'aWnrrer: All!LYiiAL%2 ! j I � f 1 I i , ' i i i ! i i i i i i Mandato Lomay residential buildings re stringent to [rte Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (�) may be superseded by more stringent conlpdance requirements listed ori the Certificate of Compliance. When this checklist is incorporated Into the permit shown ents.lse the features noted shall be considered li all parties as minimum component performance specification for the mandatory measures rAtelher they are shown elsewhere in the documents or on this checklist only. r rutty Instructions: ,Check or initial applicable bones or enter N/A it not applicable. ', DESIGNER I ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) �X `§150(m): Dugs and Fans ; 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 6Q4 and Standard 63; duds insulated b a minimum installed level of R-42 or enclosed entirely in conditioned space. Openings shad be sealed vvdlt nyypc. that meets thea �. aerosol sea�nt, or other ductctosM system pplicable requirements of UL181, UL181� or UL1818. If mastic or tapes used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shad be used. Building cavities shad not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed vmh Cloth back lubber adhesive duct tapes unless such tape is used!in combination with mastic and drawbands. 2 Building cavities, support platforms for air handlers. and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct stall not be used for conveying conditioned aa. Bu&l ft cavities and support platformmay contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reduction in the cross-sectional area of the ducts. 3. Joints and seams of duet systems and thea components shag not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and dravAb�nds. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eithe rautomatic or readgy accessible, manually operated dampers. 6. Protection of Insulation. Insulation shag be protected from damage, irtdudung that due to sunlight, moisture, equipment maintenance, curd wind but not limited to the following: Insulation exposed to weather shall be Suitable for outdoor service e.g.. protected by aluminum, sheet metal, painted canvas. or plastic cover. cellular foam insulation shag be protected as above or painted with a coating that is water retardant and provides shielding, from solar radiation that can cause degradation of the material. § 114: Pool and Spa beating Systems and Equipment j 1. Certified with TB% ttmemmal efficiency. on-off switch weatherproof operating inactions. no electric resistance heating, and no pilot i 2 System is unstaged with at least 36' of pipe between fitter and heater for fume solar. cover for outeioor pools or spas. i a. At least 36' of pipe between filter and heater for future solar heating. j b. Cover for outdoor pools or outdoor spas. i 3. Pool system has directional inlets and a circulation pump time switch. 1 I iX !! §115- Gas fired central fumaces, pool heaters. spa healers or household cooking appliances have no continuously burning pilot tight. (Exception: Non-ekvtrical cooking appliances with pilot c 150 Btuthr) i ,- J 9118, (f): Cool Roof material meet specified criteria ? Lightinq Measures ! !%(l §150(k)1: Luminaires for general fighting inkitchens shag have lamps with an; efficacy 40 lumenshratt or greater for general lighting in kitchens. This general fighting shag be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2 Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 tumensAatt or greater switched at the entrance to the room or one of the alternative to this requirement t allowed in Section 150(k)2: and recessed ceiling fodures are IC (insulation cover) approved. '• I 3.1 By EnergySoft User Number: 3412 Job Number. MTZPGAVJ2 Page -6 of 11 CoftY6e Metho- d Su'mmajy i . ThP Sllmmit .;a r]/+n. in,PSt . Part 9 of�y 3 C -2R rro =x I nle Pian �R fL��L1Li I ` _ 11 -. La Quinta, CA /14/ ! Date OO Project Address i 1 Building Permit i OocumentationAuthor (94 9) 348-2414 �:OR1Dl1ta►��rFnr.n nce r Telephone 1 Plan Ci eaMate , 'lance memod Packa a or Com afar 15 ' i Ti eld Check/l3ate Source Energy Use (kBtu/sf-yr) Standard Desi Climate Zone Proposed Compliance' ' on g Design 'M-- ate - Space Heating Space Cooling, ' 3.63 - 3.58 .i -0.04 Domestic Not Water 35.10 6.01 35'23 i -0.131 Totals 44.73 5.83 ` 44-64 0.18 0.09 GENERAL INFORRAATION r Ui C PLIES": Conditioned Floor Area: 4,744 ! 13 i Slab Floor 13uQdin . T g ype: Sin le Fam Detached Floor Construction Type: + Raised Floor,: Building Front Orientation: .(Northwest 315 de 9 i ` Total Number 4 Dwelling Units: 1.00 Fenestration Area: 2613% Number of Stories: 1 i , Total Conditioned Volume: 52,563 - - LI I Area: Slab Floor 4,744 w i BUILDING ZONE INFORMATION Zone Name '• Floor Area ea Volume # of Thermostat 'Vent �. Units Zone Type Type LIVING HVAC SLEEPING HVAC 2,197 26,584 : Hgt.'' Area 0.46 Living Livingstat 2,547 25,979 2 n/a 0.54 Sleeping SleepingStat 2 n/a OPAQUE SURFACES Solar , ' Act Type Area U -Fac. Azm. Gains Tilt Y / N Form 3 Reference Wall 15 0.061 180 90 I� ii _ II R-19 Wall Location / Comments Wall 289 0.061 135 Wall 332 0.061 225 90 X, 1— iI 90 � I R-19 Wall I laving Zone LivingZone Wall _ 108 0.061 315 Door 60 0.387 315 i- 90 _ ! �is R-19 Wan R-19 Wall Lrom g Zone i Living Zone Wall 142 0.061 45 .90 I 90 I 1 Solid Wood Door Living Zone ' R-19 Wan i 1: Roof 2,197 0.028 315 Wall 199 0.061 135 ,22 i1' i I 90 i� R-38 Roof , - Living Zone ! ng Zone ! Lin Wall 535 0.061 225 :_, 90 , 1 ; I R-19 Wall R-19 Wad 1 • Sleeping Zone l Sleeping Zone Wali 388 0.061 315 Wall 980 0.061 45 gp ,w X, 1_1 R-19 Wall R-19 Wall } Sleeping Zone Roof 2,538 0.028 315 22 ) ,rx %i R-38 Roof Sleeping Zone Sleeping Zone .I 1 : �� • i F I 11/14/2002 FENESTRATION SURFACES I Oahe #U Type Area - Factor SHGC act' Azrrt. Glazing Type Location/ 1 Window Rear 2 Window Rear South (South) (Southeast) 80.0 0.620 0 52 180 Tilt 90 Comments 3 Window Rear 4 � (Som) 80.0 47.0 0.620 1.190 0.52 135 Double Bronze 90 Double Bronze rig Living Zone Window Rear 5 (Southeast) 40.0 1.190 0.T2 135 90 Single Corner But Living Zone Window Rear 6 Window Rear (southeast) ) 35.0 0.590 0.72 0.58 135 135 -joint 90 Single Comer But -Joint Living Zone Living Zone 7 Window Rear (Southeast) (Southeast) 35.0 29.5 0.590 0.72 135 90 Double Bronze 90 Double Bronze �n9 Zone 8 Window Rear 9 (Southeast) ) 54.0 1.190 0.590 0.72 135 90 Sin 9W Comer SuhJoint �n9 Zone Window Rear (Southeast) 40 5 0.58 135 90 Double Bronze Living Zone 10 Window Right 11 (Soutiw est 35.0 1 190 1.190 0.72 135 90 Single Comer But�Joirrt Living Zone Window Right Right (Southwest) 1.190.72 045.0 0.72 225 90 Single Comer But -joint Zone �9 13 W12 indow Front (Northwest) 20.0 0:770 0.36 225 225 90 Single Corner But -joint Erving ZZone 14 Window Front (Northwest) (Northwest) 16.5 40.0 1.190 0.550 0.72 315 90 Double Bronze 90 Single Comer But Living Zone 15 Window Left 16 Window (Northeast) ) 34.5 1.190 0.72 0-65 315 145 -Joint 90 Double Bronze Livingiv n9 ZZone Left 17 Window Left (Northeast) '1 1.190 0 72 145 90 Single Comer But -Joint one Living Zone 18 Window Rear (Northeast) () (Southeast) 17.0 80.0 1.190 0.72 45 90 Single Comer But -joint 90 Single Comer But Living Zone 19 Window Rear (Southeast) 40.5 0.620 0'52 135 -joint 90 Double Bronze Living Zone 20 Window Rear 21 Window Rear 32.5 0 590 0.590 0.58 0' 135 135 90 Double Bronze Steeping Zone Steeping tone 22 Window Rear (So��) � (Southeast) 2.0 0.590 0 58 f35 90 Dodge Bronze 90 Double Bronze Steeping Zone 23 Window Right 24 Window (Southwest) 18.0 38.0 1.190 0550 0.72 0.65 135 715 90 Single Comer But -Joint Steeping Zone Sleeping Zone Right 25 Window R' (Northwest) (S�) 32.0 8.0 0.550 0.65 225 90 Double Bronze 90 Double Bronze Sleeping Zone 26 Window Right Right (Southwest) 18.0 0.590 0.58 90 Double Bronze Sleeping Zone 27 Window90 28 Right (Southwest) 16.0 1.190 0.770 0.72 0.36 225 Corner But -Joint Sleeping torte Sleeping Zone Window ght 29 Window Right (Southwest) ) (Southwest) 18.0 18.0 0.770 p 225 90 Double Brom 90 Double Bronze Sleeping Zone INTERIOR AND EXTERIOR SHADING 0.770 0.36 225 I 90 Double Bronze Steeping �� Sleeping Zone # Exterior Shade Type SHGC 1 Window Hgt wd. ! Overhang Left Fin ��,• H Right Fin Screen 2 Bust Screen 0.76 10.0 8.0 10.0' 0.5 • 10. Dist Len. Hgt 10.0 10.0 Dist Len. H gt. 3 Bur Screen 0.76 0.76 10.0 8.0 14.5 0.5 14.5 14.5 4 Bug Screen 9.0 52 14.S 0.5 14.5 14.5 5 Bug Screen 0.76 0.76 7 2 5.5 6 6.5 6.5 6 Bug Screen �'o _ 3.4 6.5 7 Bug Screen 0.76 9 0 3.4 6.5� 0.5 1 -� 6.5 6.5 $ 8 Screen 0.76 0.76 9.0 9.0 3.3 5.9 6.5� 0.5 13.0 0.5 6.5 6.5 9 Bug Seen 10 Bra Screen 0.76 9.0 4.3 13.0 0.5 13.0 13.0 13.0 13.0 71 Bug Screen 0.76 0.76 9.0 9.0 3.9 4.9 6.5` 0.5 6.5 6.5 12 Bug.Screen 13 Screen 0.76 4.0 5.0 1:5 1.5 1.51 3.5 1.5 1.5 15 15 14 Bug Screen 0.76 0.76 5.9 2.3 2.0; 0.5 2.0 2.0 15 Bug Screen 0.76 8.0 6.9 5.0 5.0 11.01 2.0 -2-01 11.0 11.0 16 Bug Screen 0.76 9.0 4.3 1.5 3.5 0.5 2.0 2.0 3.5 17 Bug Screen 18 Bug Screen 0.76 7.2 2.3 7.0 0.5 3.5 7.0 7.0 19 Bug Screen 0.76 0.76 10.0 8.0 6.5 0.5 6.5 6.5 20 Bug Screen' 0.76 9.1 9.1 4.3 3.6 6.5i 0.5 6.5 0.5 6.5 6S 21 Bug Screen 22 Buo 0.76 1.5 1.5 2.0 1.5 6.5 6.5 2.0 Screen2.0 23 Bug Screen 0.76 6.0 3.0 1 5 1.5 1.5 1.5, 24 Bug Screen 0.76 0.76 6.4 6.4 4.8 4.0 3.0 ! 1.5 1.5 j 1.5 3.0 3A 25 Bug Screen 26 Bug Screen 076 .0.76 2.0 4.0 3.0 3.5 1.5 1 3.0 3.0 27 SMScreenScreenr 0.76 6.0 6.0 3.0 9.0 1.5 ' 1.5 1.5 1.5 28 Bug Screen 0.76 6.0 9.0 3A 1 S 3.0 ; 1.5 3.0 3.0 3.0 3.0 25 HM Screen F- 0.76 6.0 9.0 3.0 ! 1.5 3.0 3.0 EnergyPro 3.1 By EnergySaft I lnit➢atdnn Time:11-d4M2 07.48 Run Code 10a��aree9a User Number: 3412 1 Job Number. MTZPC,AW-1 Paae8 of 11 Com uter Method Summary Part 2 of 3 C -2R The' Summit at PGA West - Plan 2B ` Project Title 11/14/2002 i Date FENESTRATION SURFACES , # Type Area Facto Factor SHGC pct Azm. Glazing Type t.ocatiorJ ` 30 Window Front ) Tilt Comments 31 32 Window Window Front (Northwest) Front , 18.0 8.0 0.720 0.73 0.73 '315 315 90 Double Glass Block 90 Double Sleeping Zone 33 Window (Northwest) Left ) (Northeast) 36 0' 38.0 .0'770 0.36 315 Glass Block '90 Double Bronze Sleeping Zone 34 Window Left (Northeast) 19.0 0.550 0.65 1 45 90 Double Bronze Sleeping Zone 35 Window . Left (Northeast) 1�.5 0.550 0.65 0.65 45 90 Double Bronze Sleeping Zone Sleeping Zone 36 37 Window Window Left Left (Northeast 0 590 0.58 ' 45 45 90 Double Bronze Sleeping Zone 38 Window (Northeast) Left (Northeast) 10.0 21.0'' 0.720 0.73 45 90 Double Bronze 90 Double Glass Block S�PQ1g Zone Sleeping 39 Window . Left (Northeast) 21.0 0.590 ' 0.58 45 90 Double Bronze Zone 40 Window Left (Northeast) 30.0 0.590 0 58 45 90 Double Bronze Sleeping Zone 41 Skylight Front (Northwest) 9.0 0.770 0.36 145 90 Double Bronze Sleeping Zone 0.800 0.57 315 22 Double Bronze Sleeping Zone Sleeping Zone A S INTERIOR AND EXTERIOR SHADING' # Exterior Shade T e SHGC Window i Overhang Left Fin Len_; Hgt. LExt. _ Right Fin Hgt Wd. 30 Buq Screen 0.76 4 2.0 2.0 1.0 REA. Dist Len. Hgt Dist ` Len. Hgt. 31 32 Buq Screen Bug Screen 0.76 = 6.0 3.0 2.0 3.0 2.0 2.0 2.0 33 Bug Sween 0.76 • - 6.0 6.0 3.0 1.0; 3.0 3.0 34 Bug Screen 0.76 0.76 '+ 6.4 4.8 2.0 1 5 --Q 2- 35 Bug Screen 6.4 2.01.5 2.0 2.0 36 Bu° Screen 0.76 0.76 6-4 3.0 2-5 0 2. J. 1.5 2 U 2.0 37 Bug Screen 0.76. 4.0 7 2.5 1.0, 1.52.0 ' 1.5 1.5 • 1.5 • 1.5 38 , 39 Bug Screen Bu q Screen 0.76 9.1 2.3 ' 1.5 1.0' 1.5 1.5 40 Bug Screen 0.76. 0.76 , 9.1 5.06.0 2.3 1.5 1.0 1.5 1.0 1.5 1.5 1.5 1.5 41 None 100 , j s Rr�n Initiation Time- JJr14/02 07.48.43 Run Code 1037288923 Energy% 3.1 By EnergySoft User Number 3412 Job Number: ` &MPGAW2 Page:9 of 11 c w Coil -pater Mekthoad Summ The Summit at PGA West -Plan 2f Project Tiue i n¢KMAL MASS, FOR HIGH MASS DESIGN Type Area Thick. Heat CQOgele- Hea, ,ignt (? ' . (in:) Cap. Cond. Form 3 Reference inside Location ,M., Concrete t- e,HHeai6rweioht ,s a R -Val: 350 28 1,904 Comments Conor t-He�•��.. -50 0.98 n/a --Z" j "^t19 7ene ! Slah en ['rade eight Concrete• Heavyweight' �• q 3-50 28 0 0� rt/a - LnnnQZone /Slab on Grade____ -------------- 618 3.50 28 0•98 n/a —2. �Sg@arta 2erLp /Slab on Grad, e__ 0 Sleeping Zone / Slab on Grade PERIMETER LOSSES " Type F2 '� Insulation Slab Perimeter Length Factor R -Val. , Dept Location !Comments Slab Pe tQ� __ 15 0.76.'. 0.0 114 0 Livin' Zo e Slab Perimeter 0.0 - Ll�OSL22De 2 83 0_76 Slab Perimete_ rte__ 0-0 0 Seem Zone 0.76 —4.4 r _Q Sleeping zone ---------------- HVAC SYSTEMS Heatin g Equipment Type (fumace, heat Minimum Distribution Type - f Pump, etc_} Efficiencyy and Location Thee ostat (AF UE/HSPF)(ducts/attic, �; Location / Central Furnace etc.). RuValue ! yp Comments Central r- mace n 800 AAE F Duds in Attic f 6_0 — Setback 80 /o AFUE Duds in Attic ( 6.0 LIVING HVAC Setback SLEEPING HVAC Hydronic Piping { System Name Pipe Pipe Insul. Length Diameter Thick.. !; ` , Cooling; ng• Equipment T Minimum Duct it, (air conditioner, • Efficiency Location ! Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic etc) �i R Value T Split Air Conditioner, Type Comments 12.0 SEER Ducts in Attic6.0 Split Air Conditioner 12.0 SEER DudSetback WING HVAC Ducts in Attic ' 6.0 , Setback SLEEPING HVAC' WATER HEATING SYSTEMS ! r t, Water Heater - Water Heater 'Distribution # in sputa Cap. or Rdl Tank ecoveryt Standbys R Valuesul. ' System Name Type Type Syst (Btu/hr) {gag 'Efficiency Loss (%) Ext, A O SMITH FPCR-50-234 Small Gas Recir m Tern 'A O SMITH FPCR-50-234 Small Gas Recir me+Temp —� 50 0.65 n1a n/a _i_ 46.000 50 0.65 nta n/a 1 For small gas storage (rated input <_ 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hrj, list Rated Input Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency:; REMARKS ;French Dow glass calculated per 5-20 of Residential ECM - glass plus 2" framing. This calculation is. for Base Plan 26 oriented to Northwest. , ' Run Initiation rime: jim" 2 07 48'.43 Run Code 1031288923 EnergyPro 5.1 By EnergySpfr User Number. 3412 is Job Number MT2PGAW2 r Page:10 oft i I Computer Method) S ndum C_2R Project Title V rw1 - r-lan Lti NVV 11/14/2002 Special Features and Modeling Atsufn` Date The local enforcement pt<ons Written (t agency should pay special attention to the i0errrs s enforcemstificatin anddd� tionine, the, and special verificatiat to r used a this ;� � ft ems r. Th require special based on the adequacy of the special �s�Mi�n and Win' may refect a building or design that �erwise complies [The HVAC mentation submitted, p' System "LIVING HVAC" must meet all CEC Criteria for Zona The HVAC S W Controlled system serving only Living Areas. ystem "LIVING HVAC" has R-6.0 Heating Duct insulation. Insulation levels above R-4 2 must be verified. !The HVAC System "LIVING HVAC" has R-6.0 Cooling Dud Insulation. I The nsu don levels above R-42 must be verified. HVAC System "LIVING HVAC" includes credit for a Radiant Barrier installed per Section 8.113 of a Residential Manual. ,HIGH MASS Design(see G2R) - Ve nfy Thermal Mass: 293 sgft Covered Slab Floor, 3.50" thick at Living Areas HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1904 s e The HVAC qft Exposed Slab Floor, 3.50" thick at Livrrtg Areas S�rstem "SLEEPING HVAC" must meet all CEC Criteria for a Zoriatly Controlled The HVAC System ^SLEEPING HVAC" has R-6.0 Heatingsystem serving orgy Sleeping Areas. on. Lsul tion levels above R-4-2 IThe HVAC System "SLEEPING HVAC' has R-6-0 Cooling Dud Insulation. Insulation levels above R-42 must must be verified. The HVAC System "SLEEPING HVAC" includes credit for a Radiant Barrier installed per Section 8.13 of the b - verified. HIGH MASS Design(see G2R - Verify Th p esidential Manual. fY ermat Mass: 1929 sqft Covered Slab Floor, 3.50" thick at Sleeping Areas HIGH MASS Design(see G2R) -Verify Thermal Mass: 618 s qft Exposed Slab Floor, 3.50" thick at Sleeping Areas --------------- HERS Required Verification These features mustconfirmed rrfrmed and/or tested by a HERS rater under the supervision of a CEC approved HERS Provider. The HERS rater must document the field verification d The HVAC agnostic testing of these measures cn a form CF -SR. System "WING HVAC" indudPo acs; .�. ..�___ _ 9w ultu ow credit (or a of the TXV, or measure the Refrigerant Charge and Airflow. must HVAC System "WING HVAC" is using reduced duct leakage to comply and must have diagnostic s armed by a certified HERS Rater. The results of the diaite testing of duct leakage gnostic testing must be reported on a CF -611 Form. ---- •r+� mGIuaes Ketngerant Charge and AirflAlrftooW Credit (or a TXV). A certified HERS rater must i !Provide verifification of the TXV, or measure the Refrigerant Charge and w. The HVAC! System "SLEEPING HVAC" is using reduced duct leakage to comply and must have dila [ performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -BR owe felting of duct leakage + r i i • i Plan I Field i i i Ruff Initiation Time: 11/14102 07:48: Run Code: 103T288923 3.1 By (neraySoft User Number: 3412 il Job Number. MTZPGA112, Page: 1 of 11