9812-044 (AR)LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
6" 57 8 _V31/00
Date Signature of Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code). .
( ) I, as owner of the property, am exclusively contracting with licensed
contractors ,to -construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section , B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm` under penalty, of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier Policy No.
STATE 1' UND �'�9-9t3 t1t)ltr`3�
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers;rcompensation laws of California, and agree that if I should become
subj7t to the workers' compensation provisions of Section 3700 of the Labor
Code, I shall forthwith comply with those provisions.
V ddte: Applicant
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit. subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the above-mentioned property for inspection purposes.
VSignature (Owner/Agent) Date
BUILDING PERMIT PERMIT#
91 Z 194
DATE VALUATION LOT TRACT
JOB SITE I 1 v APN
ADDRESS 55-501 SOUTURN HILLS _/69_8264)16
OWNER CONTRACTOR / DESIGNER / ENGINEER
FRANCIS WKI AKEIt, BOB EDWARD COWLRUc";f 1.0N
55-501 SOUTHF.K14 .MILLS 'I9-924 FIESTA DKIVE
Lit Quilq'1A CA 92:253 LA QUINC.A. CA 92253
(760)775-7931 CRLY 3712
USE OF PERMIT
199 S.F. GMST HOUSE ADDITION '
CUST0114CijNS111111+::`i ON
195.00
ESTIMATED COST OF CO'PiYtRUC UON'
�5,.t91i<Stl
PERMIT VEE SUNAIARY
PLA14 f: AW K I'F
I(i:t�()d J -A39-3115
'61.l1, l5
!;ONI S FRt ft";
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING
APPROVALS
MECHANICAL APPROVALS
Set Backs
Forms & Footings
�qUnderground
�Z"[ `/
Ducts
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K to Wrap
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
Final
POOLS - SPAS
BLOCKWALL
APPROVALS
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Pibg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
Appliances
Final
COMMENTS:
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp: Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service '
Sub Panels
Exterior Receptacles
G. F.I.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
Desert.Sands Unified School District .Y.
47-950 Dune Palms Road
Notice: La Quinta, CA 92253
Document Cannot Be Duplicated 760-771-8515
CERTIFICATE OF COMPLIANCE
Date . 12/2/98 APN # 769-820-016.
No. 18063 - Jurisdiction La Quinta
Owner NameFrancis Whitaker;; Permit #
No:, 55-501 Street Southern Hills .'Log #
City La Quinta l a' Zip 92253 Study Area
Tract # 'Lot # Square Footage" 195
Type of Development Residential Addition No. of Units
Comments
{
At`the present time, -the Desert'Sands Unified School District does not collect fees on, garages/carports," covered
patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement inobilehomes.
It has been determined the above-named owner is exempt from paying school fees at this time due to the following
reason:
• t
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility"fees imposed pursuant to Government Code 53080 in the amount of
0.00 X 195 or. $ -0.00 the property listed above and that building 1-
permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued
Fees Paid By N/A
}' r Telephone 7.751-7933
Name on the check +•�
By Dr. Doris Wilson
J J
Superintendent
L
Fee collected /exempted by . Ellen Patino Exempt $0.00. •�.[
Check No. N/A
Signature
r .
OTICE: Pursuant of Assembly Bill 3081 (CHAP. 549, STATS. 1996) this will serve to notify you that the 90�day approval period in which you may protest the fees or other payment identified
Jove will begin to run from the dale on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to -
)Ilect them on the District('s)(s') behalf, whichever is earlier.
Collector: Attach a copy of county or city plan check application form to district copy for all waivers.
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting
if
NO, - 9-98 MON 3 05 F1Yi t1iGI�ARCH GROUP' P* X 1,10. '• 619 '71 �6 5111. P. - 1
PGA WEST II RFSIDBNTIAL ASSQCIATION, INC;. ,
P.O. BOX 1282, LA QUINTA, CA 92253
- (760}
• �/� 776-5100 _FAX. (760) 776-5111 -
f
November 7,1998 .,
Mr. Francis Whitaker '
•55-501 Southern Hills' `
•� a
La Qulnta, CA 92253
RE: Request for Permission for Architectural Change '
Dear Mr. Whitaker:
The Architectural Committee has reviewed your plans for an addition to the Casita
portion of your. Heritage unit. The committee is pleased to inform. you that It has ,
approved these plans as submitted with the addition only entering into, the courtyard .
area of your unit. Please contact.Miguel Valenzuela with Valley Gardening Service at
(7,,60)399-1844 to coordinate any irrigation changes.
Please note that -this approval:is good fora period of six months and all work must be `
begun and compteted'by May Z3, 1998. Please contact me if you have any further .
questions or concerns.
Sincerely,
John J.Monahan
Association Manager,,
CC: Unit File f
Architectural Committee
Board of.Directors
1
TITLE 24 REPORT FOR:
Whitaker Residence
55-5.01 Souther' ;, �" ^ s ��.4. ;
La Qiiinta2:,5-
PROJECT DESIGNER::`
.; ,amu �,.,,^; �: �1•::. .,
Robert A. Pitchford • ��,�>tt�"
41-625 Eclec c Ste. .A--2:"Tri
Palm Desert, CP _"'9'2'260
(760) 34 2856 �
REPORT .PREPARED BY:
Tim Scott
BREEZE AIR CONDITIONING.
75-145 ST CHARLES PLACE -
PALM DESERT, CA 92260
(619) 346-0855
Job Number:
Date: 1/8/1999
he COMPLY 24 computer program has been used to,perform'the calculations
summarized in this -compliance report: This program has approval and is
authorized by the California Energy Commission for use.with both the
Residential and Nonresidential -Building Energy Efficiency Standards.
This program developed by Gabel Dodd Associates (510) 428-0803.
Table Of Contents for Title 24 Report
•---------------------------- -------
Cover Page .......................... 1
Table of'Contents ................................................. 2
Form CF-1R Certificate'of Compliance................................ 3—
Form MF-1R Mandatory Measures,Checkl,ist ... :......................... 5
Form P-2R Point System Summary ... :.. ......... ...... 7
Form C-2R.Computer Method Summary. (Points) .. ............ 8
Form ENV-3 Construction,Assemblies Tl
HVAC System Loads Summary. .................. 16,
Zone Heating Loads Summary .............................. :........ 18
Zone Cooling Loads Summary ..... 20
Form CF-6R Installation Certificate ..... 22
0
i
CERTIFICATE OF COMPLIANCE - Residentiale(part l'of 2) CF -1R page 3 of 22
Project Name:'Whitaker„Residence Date: 1/8/'1,999
• Address:. 55..-501 Southern Hills
La Quinta, CA 92253 Building -Permit No
Designer: Robert A. Pitchford t Checked 'by / Date
-
Documentation: BREEZE AIR CONDITIONING' COMPLY 24 User 3665
---------------------------------------------------------------------------
ti
GENERAL INFORMATION
Compliance Method: ” COMPLY 24 versiori 5.&0
Climate Zone: '_ 15 `
Conditioned Floor Area: '536 sq ft
Building -Type: Single Fam Det
Building Fronti3Orientation: 90*deg (E)
Number of Dwelling Units: 1
Floor Construction Type: Slab on Grade -
BUILDING SHELL INSULATION '
Component U -Value Location/Comments
R-21 Wall (W.21.'2x6.16) 0.059 Sitting Room/Bath
Solid Wood Door 0.387 Sitting Room/Bath
R-21 Wall (W.21.2x6.16) 0.059 Existing Bedroom/Bth/C1 -
R-38 Ro6f(R.38.2x14.16) 0.029 Sitting„Room/Bath
R-38 Roof(R.38.2xl4.16) 0.029 Existing Bedroom/Bth/Cl
lab Perimeter w/R-0•.0 0.900, Sitting Room/Bath
lab Perimeter w/R-0.0, 0.720 Sitting Room/Bath
Slab Perimeter w/R-0.0`- 0.900. Existing Bedroom/Bth/Cl
Slab Perimeter w/R-0.0 0.720 Existing Bedroom/Bth/Cl .
FENESTRATION Shading Devices + Frame
Orient.- Area U -Val Type Interior Exterior -.OH SF Type
Front (E) 12.0 0.82 Double Std Drape Standard Bug Scr N IN Metal
Left (S) 12.0' 0.72 Double Std Drape none -N N Metal
Back (W) _15.0 0.82 Double Std Drape Standard Bug Scr N 'N Metal
Skylight 9.0 0.80 Double none none N N Metal
THERMAL.MASS. Area; Think
Type Covering (sf) (in) Location/Description
Concrete, Heavyweight. Exposed 17 3.50 ..Slab on Grade
-
Concrete, Heavyweight Covered 215 3.50 Slab on Grade
Concrete,. Heavyweight Exposed. 39 3.50 Slab'on.Grade
Concrete, Heavyweight "Covered 265 3..50” Slab on'Grade
r
.
CERTIFICATE OF COMPLIANCE - Residential
(part
2 of'2),'CF-1R'
page 4 of 22
Project Name: Whitaker Residence
Date: 1/8/1999
•Documentation:
BREEZE AIR CONDITIONING
---------------------------------------------------------------------------
COMPLY 24 User -3665
HVAC SYSTEMS Minimum Distrib Type
Duct•TStat
System Type Efficiency and Location
-----------'--------------------------
RVal
----
Type
------
Location/Comments
-----------------------
Furnace 0.,800 AFUE„ Ducts in Attic
4 . 2.
SetBck
Addition Zone
SpltAirCond10.000 SEER Ducts in Attic
4.2
SetBck
SplitHtPump 6..800 HSPF"Ducts in Attic
4.2
SetBck
Exist Bdrm,Zone
SplitHtPump10.000 SEER"Ducts.in Attic
4.2.SetBck
n
Water
No Tank. Ext
WATER HEATING SYSTEMS Heater in Energy Size Insul
System Name Distribution Type Type Sys Factor. (.gal) R -Val
----
.Std Gas 501. gal or Less Standard StorGas 1 0.53. 50.0 12.0
AFUE
WATER HEATER EQUIPMENT'DETAIL` /Rec Rated -Stdby Tank Pilot
System Name System Type. Ef,f Input Loss R -Val Light
----------------------- ---------'---- ----- --- ----- - --
Std Gas,50 gal or Less, DomesticHW •0.780 40000` 0:`040 0:0 0
h-
�PECIAL FEATURES/REMARKS
COMPLIANCE STATEMENT
This Certificate of.Compliance.lists-the Building features andperformance
specifications needed to comply with;Title 24,`Parts''1'& 6 of the Califor-
nia Code of' -Regulations, and the administrative regulations to implement
them. This certificate has been signed by -the individual with overall
design responsibility. When this certificate of compliance -is submitted for
a single Building plan,to be built in multiple orientations, any shading
feature that is varied is indicated in the'Special Features/Remarks section
• F
DESIGNER or, OWNER -
(Per Business & Professions Code),
Robert A. Pitchford
41-625 Eclectic Ste. A-2
Palm Desert, CA 92260
(760) 346-2856 Lic #:
(signature) (date)
ENFORCEMENT AGENCY
Name:
Title
kgency: '
elephone:
. 4
DOCUMENTATION AUTHOR
Tim Scott
BREEZE AIR`CONDITIONING
.75=145_ST CHARLES PLACE
PALM DESERT, CA 92260
(619) 46-0.8 5
(signature) qdae)
(signature/stamp) (date)
MANDATORY,MEASURES CHECKLIST (part 1 of 2)• MF -1R page�5 of 22
---------------------------------------------------------------------------
Project�Na`me: Whitaker Residence Date: 1/8/1999
Documentation: BREEZE AIR •CONDITIONING COMPLY 24 User 3665
----------------------------------------------------------------------------
NOTE: Lowrise residential buildings subject to the Standards -must contain
these measures regardless of the compliance approach used. Items marked
with an asterisk (*) may be superseded by more stringent compliance
requirements listed on the Certificate of Compliance. When this checklist
is incorporated into the permit•documents; the features noted shall be
considered by all parties as binding minimum component performance
specifications for the mandatory measures whether they are shown elsewhere
in the documentsoron this checklist only.
BUILDING ENVELOPE MEASURES - Enforcement
• a
o/ ec. 150(a): Minimum R-19 ceiling insulation.
o Sec. 150.(b):.Loose fillYinsulation'manu_facturers
labeled R -Value.
9 ---Sec. 150(c): Minimum R-13 wall insulation in framed walls
(does not apply to exterior mass walls).
o Sec. 150.(d): Minimum R-13 raised floor insulation in framed
• floors; Minimum R-8.in concrete raised floors.
o Sec. 150(1): Slab edge insulation - water absorption rate
no greater than 0.301, water vapor transmission rate no
greater than -2.0 perm/inch.
o%c. 118: Insulation specified or installed meets.California
/Energy Commission quality standards. Indicate Type & form.
o'Sec. 116-117: Fenestration Products, Ext Doors & Infil/Exfil Controls
a. Doors and windows.between conditioned and unconditioned
spaces designed,to limit air leakage.
b. Manufactured fenestration products have label w/certifiedU-Value
c. Exterior doors and windows weatherstripped; all joints_.
and penetrations caulked and sealed.
o Sec. 150(8): Vapor barriers mandatory.in.Climate Zones 14
and" 16 only.
w -Sec. 150(f): Special.infiltration barrier installed .to�-
comply with Sec. 151 meets Commission quality standards.
a ec. 150(e): Installation of Fireplaces, Decorative Gas
Appliances and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
• b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.'
a
MANDATORY MEASURES CHECKLIST (part 1 of 2) MF -1R page 6 of 22
----------------------7----------7-----------------------------------------
Project Name: Whitaker Residence Date: 1/8/1999
*Documentation: BREEZE AIR CONDITIONING COMPLY 24 User 3665
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM.MEASURES Enforcement
o/ISec.'110-13: HVAC equipment, water heaters, showerheads
and faucets certified by the Commission.
ec. 150(i): Setback thermostat on all applicable
heating systems.
2.
3.
4.
5.
150(j): Pipe and Tank Insulation
Indirect hot water tanks (eg unfired -storage tanks or
backup solar hot.water tanks) have insulation blanket
(R-12 or greater) or combined interior/exterior insulation
(R -16 -or greater)..
First 5 feet of pipes closest to water heater tank,
non -recirculation systems, insulated (R-4 or greater.
All buried or exposed piping insulated in recirculation
sections of hot water.system.
Cooling system piping below 55 F insulated.
Piping insulated between heating source and.`indirect hot
water tank.
•0 Sec. 150(m) Ducts and Fans * ;
1. Ducts constructed, installed and sealed to comply with
UMC Sections 1002 and 1004;.ducts•insulated to a minimum
R-4.2 or ducts enclosed entirely within conditioned space..
2. Exhaust systems have backdraft or automatic dampers.
3. -Gravity ventilating systems serving conditioned space have
either automatic or readily accessiblemanually operated
dampers.
d Sec. 114':'Pool and Spa Heating Systems and Equipment
1. System is certified with 786 thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
resistance,heating and no pilot light.
2. System is installed with:
a. At least 3611,pipe between filter and heater for future
solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has'directional inlets and -a circulation
pump time switch.
/sec. 115: Gas-fired central furnace, pool 'heater, spa heater
or household cooking'appliance have no'continuously
burning pilot light. (Exception: Non -electrical cooking
appliance with pilot < 150 Btuh)
LIGHTING MEASURES
•o/ec. 150 (k) : Lighting - 40 lumens/watt or greater•,for
general lighting in"kitchens and rooms with water closets;
and recessed ceiling fixtures IC (insulation cover) approved.
t
POINT SYSTEM SUMMARY
2
P -2R page' 7 of 22
Project Name: Whitaker;Residence,
Date: 1/8/1999
Documentation: BREEZE AIR CONDITIONING
COMPLY 24 User 3665
BUILDING DATA
-------------
Conditioned Floor Area
536 sqft
Number of
Stories 1
Occupancy Type Single
Fam Det
SCORE CARD
Measure
Points
1. Roof Insulation
0.0287
(U -Value)
0
2. Wall Insulation
0.0592
(U -Value)'
-1
3. Raised Floor Insulation
0.0000
(U -Value)
3a. Controlled Vent Crawlspace
0.0
(R -Value)
-> 0
4. Slab Edge Insulation
0.7618
(f2 factor)
5. Infiltration
Standard
0,
6. Glass Heat Loss
0.79
9.00,,
3
Sum 1-6., 2
7. Fenestration Heat Gain
SC
Orientation Area % Glass
Open
Eff o
SER
North 0.0 0.0
x 0.00 =
0.0
0.00 3
East 12.0 2.2
x 0.77 =
1.7
0.86 1
South 12.0 2.2
x 0.79 =
1.8
0.86 0"
West 15.0,. 2.8
x 0.77 =
2.1
0.86 0
Skylight 9:0 1.7
x 0..53 =
0.9
1.00 .-5
8. Interior Thermal Mass
2.09
-1
9. Exterior,Wall Mass
0.00
0
Sum 7-9 -2
10. Heating System
0
Zonal Control: No
11. Cooling System
0
12. Water Heating
_. 0
"Point Total:. 0
i
COMPUTER METHOD SUMMARY (part l of 3) C -.2R page 8 of 22
Project Name: Whitaker Residence Date: 1/8/1999
*Documentation: BREEZE AIR CONDITIONING COMPLY 24 User 3665
---------------------------------------------------------------------------
POINT SYSTEM COMPLIANCE SUMMARY
Proposed Design Point Score
Budget Compliance Point Goal
GENERAL INFORMATION
Compliance Method:
Climate Zone
Conditioned Floor Area:
Building Type:.
Building Front Orientation:
Number of Dwelling Units":
Number of Stories:
Floor Construction Type:
Total. Conditioned Volume:
Conditioned Footprint Area:
Ground Floor Area:
BUILDING ZONE INFORMATION
Floor
&one Name Area
Addition Zone 232
Exist Bdrm Zone 304
OPAQUE SURFACES Act Solar
0 Points *BUILDING COMPLIES*
0 Points
COMPLY 24 version 5.00,
15
536 sqft
Single Fam Det
90 deg (E)'
1
1
Slab -on Grade
4824,cuf"t
536 sqft
536 sqft
# of Vent
Volume Units Zone Type TStat Type Hgt Area
2088 0.43 Conditioned Setback 2 n/a
2736 0.57 Conditioned Setback 2 n/a
Type Area U-Val.Azm Tilt Gains Form.3 Reference Location/Comments
ZONE NAME = Addition Zone
Wall
95
0.059
90
90
Yes
R-21
Wall (W.21.2x6.16)
Sitting
Room/Bath
Door
121
0.387
90
90
Yes
Solid
Wood Door
Sitting
Room/Bath
Wall
137
0.059
180,
90
Yes
R-21
Wall (W.21:2x6.16)
Sitting
Room/Bath
Wall
18
2"
0.059
270
90
Yes
R-21
Wall ,(W.21.2x6.16)
Sitting
Room/Bath-
oom/BathRoof
Roof
232
0.029
0
22
Yes
R-38.Roof(,R.38.2x1-4.16)
Sitting.Room/Bath
ZONE
NAME
= Exist Bdrm
Zone
Wall
149
0.059
0
90
Yes
R-21
Wall (W.21.2x6.16)
Existing
Bedroom/Bth/Cl
Wall
162
0.059
90..
90
Yes
R-21
Wall (W.21.2x6.16)
Existing
Bedroom/Bth/Cl
Wall
147
0.059
270
90
Yes
R-21
Wall (W.21 -2x6.16)
Existing
Bedroom/Bth/Cl
Roof
30318
0.029
0
22
Yes
R-38
Roof(R.38.2x14,.1.6)
Existing
Bedroom/Bth/C1
E
COMPUTER METHOD SUMMARY (part 2 of 3) C -2R page 9,of 22
Project Name: Whitaker,.Residence, Date: 1/8/1999
_Documentation: BREEZE AIR CONDITIONING COMPLY 24 User 3665
PERIMETER LOSSES F2 Insulation
Type Length Factor R -Val Depth Location/Comments
ZONE NAME Addition Zone
Exposed 10."0 0.90 0.0 O in Sitting Room/Bath
Covered 36.0• 0.72 0.0 0 in 'Sitting Room/Bath
ZONE NAME = Exist Bdrm Zone
Exposed 13.0,': 0.90 0.0 0 in ,Existing Bedroom/Bth/Cl
Covered 40,0', 0.72 0.0 O in Existing Bedroom/Bth/Cl
FENESTRATION_ SURFACES SC
Act Glass
# Type Area`Frame Div U -Val Azm Tilt Only Location/Comments.
ZONE -NAME = Addition Zone
1 Wdw Front (E) 12..O.Metal No 0.82 90 90 0.88 Sitting Room/Bath
2 Wdw Left (S)- 4:0 Metal No. 0.72 180 90" 0.88 Sitting Room/Bath-
3 Wdw Left (S) 4.0'Metal No 0.72 180 90 0.88 Sitting Room/Bath
4-Wdw Left (S) 4:O Metal No 0.72 180 90 0.88 Sitting Room/Bath'-
ZONE
oom,/BathZONE NAME = Exist Bdrm Zone
•5 Wdw Back (W) 15.0'.Metal No 0.82 270 90 0>.88 Existing Bedroom/Bth/Cl
6 Sky Right (N) 9.0Metal No 0:80. 0 0 0.59 Existing Bedroom/Bth/Cl
INTERIOR & EXTERIOR SHADING,
#
Type
Interior Shade Type
SC
Exterior Shade Type
SC
1
Wdw
Std Drape
0.78
Standard-,BugScreen
0.87
2
Wdw
Std Drape
0.78
None
1.00
3
Wdw
Std Drape
0.78
None.
1.00
4
Wdw
Std Drape
0.78
None
1.00
5
Wdw
Std Drape
0.78
Standard Screen.
0.87
6
Sky
None
1.00
None
1.00
COMPUTER METHOD SUMMARY (part 3., -of 3)
-=--------------=--------------------------=---------=-----------------------
C7'2R page 10 of'22
.Project.Name: Whitaker Residence
Date: -1/8/1999
Documentation: .BREEZE AIR CONDITIONING
COMPLY 24 User 3665
OVERHANGS/SIDE FINS
--Window-- -----Overhang------ ----Left Fin--- ---Right Fin--
#' Type Ht Wd Len Ht LExt RExt Dist Len
Ht Dist Len Ht
NONE
THERMAL MASS Area Thick Heat
Inside Location
Type (sf)(in) Cap Cond Form 3 Reference R -Val. Comments
ZONE NAME = Addition Zone,
Exposed Slab .17 3.50 28 0.98 n/a
'0
Covered Slab 215 3.50 28 0.98 n/a
2
ZONE NAME = Exist Bdrm Zone
Exposed Slab 39 3.50 28 0.98 n/a
0
Covered Slab, 265, 3.50 28 0.98 n/a
2'
HVAC SYSTEMS Minimum Distrib Type Duct TStat
System Type Efficiency and Location RVal Type
Location/Comments
urnace 0.800 AFUE Ducts in Attic 4.2 SetBck
Addition Zone
pltAirCond10.000 SEER,Ducts in Attic 4.2 SetBck
SplitHtPump 6.800 HSPF'Ducts in Attic 4.2 SetBck
Exist Bdrm Zone
SplitHtPump10.000 SEER Ducts in Attic 4.2.SetBck
Water
No. Tank Ext.
WATER HEATING SYSTEMS Heater
in Energy Size Insul
System Name„ Distribution Type Type
Sys Factor (gal) R -Val
Std Gas 50 gal or Less Standard StorGas
1 0.53 50.0 12.0
AFUE
WATER HEATER EQUIPMENT_DETAIL /Rec Rated
Stdby Tank Pilot
System Name System Type Eff Input
Loss R -Val Light
Std Gas 50 gal or Less DomesticHW 0.780 40000
0..040 0.10 0
SPECIAL FEATURES/REMARKS
PROPOSED CONSTRUCTION ASSEMBLY
ENV -3 page 11 of 22
Whitaker: Residence
Date: 1/8/1'999
�Project-Name:
Documentation: BREEZE AIR CONDITIONING.
COMPLY 24 User 3665
COMPONENT;DESCRIPTION
Assembly Name: R-2.1 Wall (W.21.2x6.16)
Assembly Type: Wall
Assembly Tilt: 90 deg (Vertical)
Framing.Material: Wood
Framing Spacing:, _". O.C.
Framing Percent:.15.0'0
Absorptivity: 0-.70.
-------------------------------
Sketch of Construction Assembly
Roughness: Stucco, Wood Shingles
ASSEMBLY U -VALUE
Th R -.Value
Construct -ion Components
Fr (in) Cavity Frame
---------------------------------------------------------------------------
Air Film'
0..17 0.17
�utside
1. Stucco
0.875 0.17 0.17
2. Membrane, Vapor -Permeable Felt
0.010 0.06 0.06
3. Insulation, Mineral Fiber, R721
* 5.500 21.00. 5.45
4. Gypsum, or Plaster. Board
0.'500 0.45 0.45
5.
G.
7-.
8:
9.
Inside Air Film
0.68 0.68
w
Unadjusted R -Values 22.53 6.98
ADJUSTMENT FOR FRAMING
(1 /22.5,3.),-x (0.85) + (1 / 6.98) x
(0.15) _ 0.059
'rOrrAT. TT-ITAT.TTT.' a
Weight.
eat Capacity:
PROPOSED CONSTRUCTION ASSEMBLY
ENV -3. page 12 of 22 -
Project Name: Whitaker;Residence..
Date: 1/8/1999
Documentation: BREEZE AIR CONDITIONING COMPLY 24 User 3665
COMPONENT,DESCRIPTION
Assembly Name: R-38 Roof(R.38.2x14.16)"
------------------------------
Assembly Type: Roof,
Assembly Tilt: 22 deg (Tilted Up)
Framing Material: Wood
Framing Spacing:, ".O.C.
.Framing Percent: 10.0
Absorptivity: 0.70
-------------------------------
Sketch of Construction Assembly
Roughness: Concrete, Asph. Shingles
ASSEMBLY U -VALUE
Th R -Value -
Construction Components
Fr (in) Cavity Frame
------------------------------------------------7----------=---------------
4utside Air Film
0.•17 0.17
1. Roofing, T'il-e
0.,500 0.05 0.05
2. Membrane,' Vapor -Permeable Felt
0.010 0.06 0.06
3. Plywood
0.500 0.62 0.62
4. Air Space
* 1.750 0.77 1.73
5. Insulation, Mineral Fiber, R-38 * 11.500 38.00 11.39
6. Gypsum or Plaster.Board
0.500 .0.45 0.45
7.
8.
9.
Inside Air Film
0.61 0.61
Unadjusted R -Values 40.73 15.08
ADJUSTMENT FOR FRAMING
(1 /40.73)'x (0.90) + (1 /15.08) x (0.10) = 0.029
TOTAL U. -VALUE = 0.029
TOTAL R -VALUE = 34.81
Weight: 12.9 lb/sqft
�ieat Capacity: 4.06
PROPOSED CONSTRUCTION ASSEMBLY -ENV-3 page 13 of 22
-Project Name:'Whitaker Residence Date: 1/8/1999
*Documentation: BREEZE AIR CONDITIONING COMPLY 24 User 3665
COMPONENT DESCRIPTION Assembly Name: Carpeted -Slab On Grade
-------------------------------
Assembly Type: Floor
Assembly Tilt: 180 deg (Horizontal Floor)
Framing Material: None
Framing Spacing: O.C.
Framing Percent:,. 0.0
Absorptivity: 0.00
-------------------------------
Sketch of Construction Assembly Roughness:,Concrete,. Asph. Shingles
ASSEMBLY U -VALUE
Th
R -Value
Construction Components
Fr' (in)
Cavity
Frame
Outside Air Film
0.17
0.17
1. Earth
24.000
4.00
4.00
2. Concrete, 140 lb, Not
Dried
3.500
0.28
0.28
3. Flooring,. Carpet and
Fibrous
Pad
0.250
2.08
2.08
4.
S.
6
7.
8.
9.
Inside Air' Film
0.92
0.92
--------------------------------------
Unadjusted
R -Values
7.45
7.45
ADJUSTMENT FOR FRAMING
(1 / 7.45) x (1.00) + (1
/-7.45)
x (0.00) =
0.1314
"TOTAL U -VALUE =
0.134
TOTAL R -VALUE =
7.45
Weight:
210.9
lb/sgft
eat Capacity:
42.19
PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page ;14 of 22
.Project Name: Whitaker Residence Date: 1/8/1999
Documentation: BREEZE AIR.CONDITIONING COMPLY 24 User 3665
COMPONENT DESCRIPTION Assembly,Name: Exposed Slab.On Grade.
Assembly Type: Floor
Assembly.Tilt:.•180'deg (Horizontal Floor)
Framing Material: None
Framing Spacing: _" O. C::
Framing Percent: 0.0 01
Absorptivity: 0.00
Sketch of Construction'Assembly Roughness: 'Concrete, Asph. Shingles
ASSEMBLY U -VALUE
Th
R -Value
Construction Components
Fr (in)
Cavity
Frame
Air Film
0.17
0.17
�utside
1. Earth
24.000
4.00
4.00'
2. Concrete, 140 lb, Not Dried
3.500
0.28
0.28
3.
4.
5.
6.
7
8.
9.
Inside Air Film
0.92.
0-92
---------------------------------------------------------------------------
Unadjusted'R-Values
5.37
5.37
ADJUSTMENT FOR FRAMING
(1 / 5.37) x (1.00). + (1 / 5.37) x (0.0.0),. _
Weight:
Weat Capacity:
210.8 lb/sgft
42.17
0.186
TOTAL U -VALUE _
TOTAL R -VALUE =
0,186
5.37
PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 15 of 22
----------------------------------------------------------------------------
Project Name: Whitaker Residence Date: 1/8/1999
Documentation: BREEZE AIR CONDITIONING, COMPLY 24 .User 3665.
---------------------------------------------------------------------------
COMPONENT DESCRIPTION Assembly Name:'Solid Wood Door
Assembly Type: Door.
Assembly Tilt: 90 deg (Vertical)
Framing Material.: None
Framing -Spacing: _" O.C.
Framing.Percent: 0.0 0 '
Absorptivity: 0.70
-------------------------------
Sketch.of Construction;Assembly Roughness:_.Glass, Paint on Pine,
ASSEMBLY U -VALUE
Th R -Value
Construction Components, Fr (in) Cavity Frame
Outside Air Film 0.17 0.17
• 1. Softwood, Douglas Fir=Larch .1.750 1.73 1.73
2.
3.
4.
5.
6.
7.
8.
9.
Inside Air Film 0.68 0.68
Unadjusted R -Values 2.58 2.58
ADJUSTMENT FOR FRAMING
(1 / 2.58) x (1.00) + (1 / 2.58)'x (0.00)
Weight: 5.1 lb/,sgft
eat Capacity: 1.99
0.387
TOTAL U -VALUE'= 0.387
TOTAL R -VALUE = 2.58
HVAC SYSTEM HEATING \& COOLING LOAD
SUMMARY
page 16
of 22
Project Name:.Whitaker`Residence
Date: 1/8/1999
*Documentation:
BREEZE AIR CONDITIONING
---------------------------------------------------------------------------
COMPLY 24 User
3665
HVAC SYSTEM DESCRIPTION
HVAC System Name:
Addition Zone
Heating System Name:
Existing FAU
Cooling System`�Name:
Existing Cond Unit'
System Multiplier:
1
Fan Schedule:
CA Daytime Fans,.
Peak Load Method:
COINCIDENT
Relative Humidity:
50 0
COOLING
ZONES ON THIS SYSTEM PEAK
HEATING
PEAK SENSIBLE LATENT
Sitting Room/Bath (Jan 12am)
5401
(Aug 2pm) 4451
634
TOTAL ZONE LOAD
5401
445.1"
634
Duct Gains & Losses:
540
445
Ventilation: ( 0 CFM)
0(
0 CFM) 0
0
Return Air Lighting Gain
0
Supply/Return Fan Gain:
0
0
TOTAL SYSTEM LOAD
---=---
5941
---------------
4896
634
SYSTEM OUTPUT AT DESIGN CONDITIONS
MAIN HEATING & COOLING SYSTEM 89000 34086 6925
TOTAL SYSTEM OUTPUT 89000 34086 6925
NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will heat or cool this zone during the design conditions indicated.
These numbers include no safety factor, and"the HVAC -contractor should
oversize by a reasonable margin to account for variations in weather
conditions and the pick-up capacity required to.bring the zone to"temper-
ature as a result of a setback thermostat. Those responsible for final
equipment selection should note that Sensible and Latent Cooling Loads are
indicated to allow for accurate comparison with manufacturer's output data.
HVAC SYSTEM HEATING & COOLING LOAD SUMMARY
page,1,7 of 22
-------------------------------------------------_----
Project Name: Whitaker' Residence
---------------------
Date':_ 1/'8/1999,,
Documentation: BREEZE AIR'CONDITIONING
COMPLY 24 User 3665
HVAC SYSTEM DESCRIPTION.:
A "
HVAC System Name: "f
Exist Bdrm Zone+
Heating System Name:
Goodman WMS18-1
Cooling System Name:
System Multiplier-
1
Fan-Schedule:- i _
CA Daytime. Fans
Peak Load Method-
COINCIDENT
Relative Humidity:
500
r
COOLING
ZONES ON THIS,SYSTEM %,PEAK "' HEATING
.PEAK SENSIBLE k LATENT
----------------------- - - - - -- - - - - - - -
- - - - --------
- ---Existing
Bedroom/Bth/,Cl (Jan 12am)_ 9145
(Aug 2pm) 9675 830
-------- "
-------
TOTAL-,ZONE LOAD 9145
------
9675 830
Duct Gains & Losses: 915
968
Ventilation: ( 0 CFM) i0
( 0 CFM) 0 0
Return 'Airy Lighting`'Gain
0
Supply/Return Fan'Gain: 0
0 "
TOTAf_
SYSTEMyLOAD 10060
10643 830
SYSTEM OUTPUT AT DESIGN CONDITIONS
MAIN HEATING &•COOL'ING SYSTEM - 1389.5'
15032 125
-------
TOTAL SYSTEM OUTPUT 13895
i,-------- "--.----
15032 125'
NOTE: The TOTAL SYSTEM LOAD shown represents
the minimum size'equipment
which will heat or cool this zone during the
design conditions indicated.
These numbers include no 'safety factor, and
the HVAC contractor should
oversize by a reasonable margin to account.for'variations-in
weather
conditions',and the pick.up-capacity required
to bring the zone to temper-
ature as a,result of a; setback thermostat.
Those responsible for final
equipment.selectibn should note that Sensible
and Latent Cooling Loads are
'indicated to allow,for.accurate comparison with manufacturer's output.-data.
{
"
RESIDENTIAL ZONE HEATING LOAD SUMMARY
page
18 of 22
Project Name: Whitaker Residence
Date: 1/8/1999
'*Documentation:..BREEZE
AIR,CONDITIONING
COMPLY.24 User'3665
Zone Name:
Sitting Room/Bathe
Design Indoor Dry Bulb Temperature:
70.F"
Design Outdoor Winter Dry Bulb Temperature:
32 F
Design Temperature Difference:
38 F'
Conduction..
Area
U -Value
TD.
Btu/hr".
R-21 Wall (W.21.2x6.16)
360.0
x
0:0592.
x 38..0
810
Solid Wood Door
21.0
x
0.387.2
x'38'.0
= 309
Double Clear Default(R)
12.0
x
0.8200
x 38.0
_. 374
Double Clear Default(R)
12.0
x
0.7200
x 38.0.
_ 328"
R-38 Roof(R.3.8.2x14.16)
232.0
x
0.0287
x 38.0
_ 253
Slab on Grade Perim =
10.0
x
42
= 415
" Slab on Grade' Perim =
36.0
x
42
= 149.4
Infiltration: 1.00 x 0:018 x` 232 sf
x 9.6
ft
x 1.00 AC
x 38..0
= 1418
TOTAL
HOURLY
HEAT
-LOSS FOR
ZONE
5401
Oieating AirFlow: 5401 Btu/hr /
[1.07,x
35
F DeltaT).]
_ 144
cfm
RESIDENTIAL ZONE HEATING LOAD SUMMARY
----------------------------------------------------------------------------
page '19 of 22
Project Name: Whitaker,Residence
Date: 1/8/1999
*Documentation:.BREEZE
AIR,CONDITIONING
COMPLY 24 User
3665
Zone.Name:
Existing
Bedroom/13th/CL,
Design Indoor Dry Bulb, Temperature:
70 F
Design Outdoor Winter Dry:tBulb Temperature:
32 F
Design Temperature Difference:
38,F'
Conduction -
Area,
U -Value
TD Btu/hr
R-21 Wall (W.21.2x6.16)
458.0 x
0.0592
x 38.0 _
1030
Double Clear Default(R)
15.0 x
0.8200
x 38.0 =
467
Double Bronze Skylight
9.0 x
0.8000
x 38.0
274
R-38 Roof(R.38.2xl4.16)
3038.0. x
0.0287:
x 38.0
3317
Slab on'Grade Perim =
13.0 x
42
540
Slab on Grade Perim =
40.0 x
42 =
1660
Infiltration: 1.00 x 0.018 x 304 sf
x 9.0 ft
x,1..00 AC
x 38.0 =
185.8
TOTAL
HOURLY HEAT
LOSS FOR
ZONE
9145
eating AirFlow: 9145 Btu/hr /
[1.07 x 351F
DeltaT)].
= 2.44 cfm
RESIDENTIAL.ZONE COOLING LOAD SUMMARY
page
20 of 22
Project'Name: Whitaker Residence
Date:
1/8/1999
*Documentation:.BREEZE
AIR CONDITIONING
COMPLY
24 User.3665
Zone Name:
Sitting Room/Bath'
Design Indoor Dry Bu1b;Temperature:
78 F
Design Outdoor Summer Dry Bulb Temperature:.
112 F
Design Temperature Difference:
34 F
Conduction
Area'
U -Value
DETD
Btu/hr
R-2.1 Wall (W.2.1.2x6,.16)
360.0
x
01.05.92 x
27.6
_ 588
Solid Wood Door
21.0
x
0.3872 x
27.6
_ 224
Double Clear Default(R)
12.0
x
0.8.200 x
34.0
= 335
Double -Clear Default(R)
12.0
x
0.7200 x
34.0
= 294
R-38 Roof(R.38.2xl4.16)
232.0
x
0.0287 x
48.0
= 320
Infiltration: 1.00-x 0'.018 x 23.2.sf
x 9.0 ft
x 1.00 AC x
34.0
= 1268
Shaded
Unshaded
Solar Gain. Orient. Area- SGF
Area SGF
SC
Double Clear Default(R)` East [
0.0 x 15
+
12.0 x 731
x 0.66
= 577
Double Clear Default(R) South [
0.0 x 15
+
4.0 x 32]
x 0.68
= 87
Double Clear Default(R) South [
0.0 "x 15
+
4.0 x 321
x 0.68
= 87
ouble Clear Default(R) South [
0.0 x 15-+
4.0 x 321
x 0.68
= 87
Internal Gain Op Frac.
Area
Heat Gain 'Conv.
-------------------------------
Lighting 1.00 x.
------
232.0
x
---------
0.200 x
-----
3.413
= 158
Equipment 1.00' x
232.0
x.
0.100 x
3.413
= 79
Occupants 1.00 x
232.0
x
255 /
250
= 237
TOTAL HOURLY SENSIBLE HEAT.GAIN
FOR ZONE
4451
.Latent Gain Op Frac:,
Area
Heat Gain
Conv.,
Btu/hr
Equipment 1.00 x
232.0
x
0.000 x -3.413
= 0
Occupants 1.00 x-
232.0
x
255 /
250
237
Infiltration: 1.00 x 0.018 x 232 sf
x 9.0 ft.
x 1.00 AC x
9.8
= 364
TOTAL HOURLY
LATENT HEAT
GAIN FOR ZONE
634
Cooling AirFlow: 4451 Btu/hr /
[1.07 x
23
F.DeltaT)]
= 181
cfm
RESIDENTIAL ZONE COOLING LOAD'SUMMARY
-----------------
page 21 of 22
Project-Name: Whitaker
Residence
Dater
1/8/1999
•Documentation:
BREEZE AIR CONDITIONING
"
COMPLY 24 User 3665
Zone Name:..
Existing Bedroom/Bth/C1
Design Indoor Dry Bulb.Temperature:
78 F
Design Outdoor Summer Dry Bulb Temperature:
112 F,
Design Temperature,Di.fference:
34 F
Conduction,
Area
U -Value
DETD
Btu/hr
.R-21 Wall (W.21.2x6.16)
458.0 x
0.0592
x 27.6 =
748
Double Clear Default(R)
"15.0 x
0.8200,
x 34.0=
418
Double Bronze Skylight;`
9.0 x
0.8000
x 34.0 =
245
R-38 Roof(R.38.2xl4.16)
3038.0 x
0.0287
x 48.0 =
4189
Infiltration: 1.00 x 0.018.x
304 sf
x 9.0 ft
x 1.00 AC
x 34.0 =
1662 "
Shaded -
Unshaded
.Solar Gain
Orient. Area SGF
Area SGF
SC
Double Clear Default(R)
West [
0.0-x 15 +
15.0 x-731
x 0.66
= 721
Double Bronze Skylight
Skylight [
0.0 X'15 +
9.0 x1521
x 0.53
= 726
*nternal Gain _
Op Frac.
Area Heat Gain
------
Conv.
---------=-------=--
Lighting
--------
1.00 x
--------=
304.0 x
0.200 x,
------
3.'413 =
.208
Equipment
1.00 x
304.0- x
0.100 x
3.413, =
104
Occupants
1.00 x
304.0 x
255 /
"250 =
310
TOTAL HOURLY SENSIBLE HEAT.GAIN
FOR -ZONE
9675
.Latent Gain
Op Frac.
Area Heat Gain
Conv:
Btu/hr
Equipment
1.00 x
304.0 x
0.000 x
3.413 =
0
Occupants
1.0.0 x
304.0 x
255 /
250 =
310
Infiltration: 1.00.x 0.018
x 30.4 sf
x '9.0 ft -x
1.00 AC
x 9.8 =
477
TOTAL HOURLY
LATENT HEAT
GAIN FOR"ZONE
830
Cooling AirFlow:
9675 Btu/hr`./
[1-07 x 23
F DeltaT)]
= 392
cfm.
INSTALLATION CERTIFICATE CF=6R page 22 of 22
------------------------------------------------------
Project•Name: Whitaker Residence Date: 1/8/1999
•Documentation:.BREEZE AIR CONDITIONING COMPLY 24 User 3665
-----------------------------------------------------------------------------
I, the undersigned, verify that the equipment listed in the category above
my signature is,the-actual equipment installed and that the equipment
meets or exceeds the requirements of the Appliance Efficiency Standards.
In addition, I have verified that the equipment is equivalent to or more
efficient than the equipment specified on the Certificate,of'Compliance
submitted to demonstrate compliance with the Energy Effitiency Standards
for Residential Buildings.
HVAC SYSTEMS
Heat. Equip CEC Certified Manuf. Actual Distrib Type Duct Heat Heat
System Type Make&.Model Number Eff. and Location RVal Load Output
Furnace Existing FAU 0.800 Ducts in Attic 4.2 5941 89000
SplitHtPump Goodman'WMS1•8=1 6.800 Ducts in Attic 4.2 10060 13895
Cool. Equip CEC Certified'Manuf. Actual •Distrib Type ,Duct
System,Type Make & Model Number Efficiency and Location RVal
pltAirCond Existing Cond Unit• 10.000 SEER Ducts. in Attic 4.2
plitHtPump 10.000 SEER Ducts in Attic. 4.2
Signature Date Name,
Water .No. Tank, Ext.
WATER HEATING SYSTEMS Heater in Energy Size Insul
CEC Cert. Make & Model,' Distribution Type Type._- 'Sys Factor (gal) R -Val
-------------- - -------- ------------------ ------- --- ----
Std
-- Std Gas 50 gal or Less Standard StorGas 1 0.53 50.0 12.0
AFUE
WATER HEATER EQUIPMENT DETAIL /Rec Rated- Stdby Tank Pilot
System Name System Type Eff'• Input Loss '.R -Val Light
Std Gas 50 gal.or Less DomesticHW 0.780 40000 0.040 '0.0 0
FAUCETS & SHOWER HEADS;.
All faucets and showerheads are listed --in the Commissions Directory Of
Certified Faucets And Showerheads, pursuant to Title 24, Part 6,
Subchapter 2, Section ill.
Signature ..Date 'Name '