Loading...
BRES2014-1088n 78-495 CALLE TAMPICO 10/27/2014. LA QUINTA, CALIFORNIA 92253 w Application Number: BRES2014-1088 Property Address: 55585 SOUTHERN HILLS APN: 775200013 Application Description: 861SF CASITA ADDITION Property Zoning: z Application Valuation: $49,249.20 Applicant: ROBERT PITCHFORD 77622 COUNTRY CLUB DR. PALM DESERT, CA 92211 44fvaw . v COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Busine and Professions Code, and my License is in full force and effect. License Class: B License No.: 903943 Date, -7 Contractor. OWNER -BUILDER DECLAMATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold. within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of'sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. 8.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit "is issued (Sec. 3097, Civ. Q. Lender's Name: Lender's Address: . S le - VOICE (760) 777-7125 , FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/27/2014. Owner: THOMAS BOGGS. 804 MANHATTAN AVE MANHATTAN BEACH, CA 92253 z CD rn M Contractor: �i r—=D & R REPAIR INC zo M v 44630 FRANKLIN COURT D 4::- LA QUINTA, CA 92253 z—� -a (760)218-6414 Llc. No.: 903943 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the �of for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should beme subject to the workers' compensation provisions of Section 3700 of the La or esu I shall forthwith. comply with t ose visions. IN�nK�, Date: I v Z, 7pr Applican .. WARNING: FAILURE TO SECURE WORKERS' COMPE A 1 COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PE S AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and ' employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above informatio_ 's correct. I agree to comply with all city and county ordinances and state laws relating to uifd'n construction, and hereby authorize representatives of this city to enter upon th ab e mentioned pr ert for inspection purposes. Date: _ Signature (Applicant or Agent): YL„ FINANCIAL INFORMATION w. PAID 'DATE �; ,, � ADDITION, EA ADDITIONAL 500 SF -101-0000-42400 f' 0 fa $122.98 $0.00. . PAID BY:TvaMETHOD ' " "RECEIPT# CHECK 9t CLTDBY_0; �i� DESCRIPTION'.' �A <a :"ACCOUNT" 'z QTY 'AMOUNT +PAID..' t : PAID DATE' ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $124.72 $0.00 PAID BY +' • +� * -, * METHOD SCHECK #j yy ''CLTD BY, `r DESCRIPTION;, 3- ACCOUNT QTY ;y*, PAIDs:1 PAID DATE ,; r ;AMOUNT a� ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $34.32 $0.00 BY 'f i CHEC6 ' CLTD.BY'M y.',PAID DESCRIPJIONN n3 ACCOUNT " QTY ''' 'AMOUNT.'' ' r * PAID PAID:DATE „ ,,, t ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $34.80 $0.00 PAID BY < r METHOD �4 >' �u RECEIPT;# CHECK #. BY. =xn_� , o.';Y r,CLTD . {DESCRIPTION s Y fir` ' Vis' -ACCOUNT ' , �PAIDV : [PAID. DATE; .`� s „QTY . �AMO.UNT:y�=�. ADDITION, FIRST 100 SF 101-0000-42400 0 $120.12 $0.00 PAIDBY �` '�- METHOD "`r� = >,CHECK# ' CLTD BY, + h, ,fit , ,RECEIPT# �, _ DESCRIPTION ; F41t T° 't `' ACCOUNT `ie QTY" AMOUNT PAID; r;z4; PAID DATE ADDITION, FIRST 100 SF 101-0000-42400- 0 $120.83 $0.00 tC r "PAID BY ;' METHOD . d ar 3*y.RECEIPT.# t.w� CHECK #';�5: r?CLTD. BY,4 „ r „i^ } i DESCRIPTION> _ t`ACCOUNT ; QTY AMOUNTS , PAID ' °PAID'DATE , t, ADDITION, FIRST 100 SF PC 101-0000-42600 0 $168.74 $0.00 PAID BY; ��.; r, �. ' -METHOD ” ; RECEIPT# 4.., #. CLTD BYE' t ;CHECK .. .. , k 'DESCRIPTION ;�* `!� ACCOUNT: QTY 'AMOUNT =' it _y ;:PAID.;'PAID;DATE ,', ADDITION, FIRST 100 SF PC 101-0000-42600 0 $171.14 $0.00 PAID BY < Ni , ' ' METHOD r 'RECEIPT.#� G CHECK#�. f:tCLTD'BY� 1 Total Paid forADDITION: $897.65 $0.00 °'' `� " DESCRIPTION �" =x, ~,- ACCOUNT ; ' •QTY: ''� AMOUNT '" � PAID " RPAID DATE' D . k y i 74¢ . HOURLY PLAN CHECK - YES 101-0000-42600 2.25 $157.50 $0.00 ri'ti PAID BY,i-, ;;� '4 P e°'d L°` CHECK#s, CLTD BYy 'L ,�� ,� f'METHOD�"�'�- .itfi'�.RECEI T#x �. Total Paid for BLDG CITY STAFF - PER HOUR: $157.50 $0.00 DESCRIPTIO_Nf ai e g ACCOUNT ,• QTY ', AMOUN_T ' PAID '77 t DATE : t r ; , ;PAIDY BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 PAID. By i,, METHOD_, ;RECEIPT #.,,�J` wCHECK `DESCRIPTION Ivqlyt! =AMOUNT PAID ID, PAIDDATE tACCOUNTI, SSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 PAIDiY; METHOD RECEIPT:# , CHE K # LTD BY , DESCRIPTION ACCOUNT AMOUNT i t4­1_.,_4� PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 PAID!BY'* 'e, k "'METHOD RECEI CHECK #-,L, LT p BY' t" Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $6.00 $0.00 DESCRIPTION J "ACCOUNT. QTY 'AMOUNT . PAID 'PAID.DATE DEVICES, ADDITIONAL 101-0000-42403 0 $133.28 $0.00 `4 �U' PAID BY :METHOD'.' .,.RECEIPT.# CHECK.# CLTD By DESCRIP1 ACCOUNT MIt OUNT PAIDr_ !!AID, DATE 4,t DEVICES, ADDITIONAL PC 101-0000-42600 0 $33.60 $0.00 �PAI06Y -M METHOD E PT REC I < j!*C !',HEC ­',-CLTI) B K. DESCRIPTION: x ACCOUNTQTY -,'AMOUNT" PAID,PAID'DATE 1, DEVICES, FIRST 20 101-0000-42403 0 .$23.83 $0.00 'PAID'6Y" METHOD RECEIPT'# CHECK # C LT BY, 'i - 'ACC6UNT':'4ATYz XA M 0 U N T u3 PAID iPAIDbATE ;DESCRIPTION V :��_ 6 DEVICES, FIRST 20 PC 101-0000-42600 0 $23.83 $0.00 d. MIDBy METHOD RECE!fT 1: fig CH ECK,# •'.,CLTD.BY.-' _4 Total Paid for ELECTRICAL: $214.54 $0.00 DESCRIPTION'-, ACCOUNT.. QTY' AM6UNTt:'� PAID e - - PAID. DATE; CONDENSER/COMPRESSOR 101-0000-42402 0 $35.75 $0.00 PAID BY METHOD E, REC.,IPT#,,:,, CHECK .#',, CLT D.,BY, 1DE CRPTION' 'ACCOUNT AmdUN 'PAID DATE y CONDENSER/COMPRESSOR 101-0.000-42402 04 $36.26 $0.00 By..�Jt ,,-ceME'THODc. EC' R EIPT, CHECK #, f�,CLTD BY r. aPAID '-DESCRIPTION 7- CC6 U N- T - ;PTY;, qLINT�:­� �PAID--,. PAID DATE -A CONDENSER/COMPRESSOR PC 101-000042600 0 $23.93 $0.00 3*PAI DB Y !�,­METHOD RE C EEI PT, 4 HECK S DESCRIPTION _��A ACCOUNT cc AMOUNT IQTM D'DATE CONDENSER/COMPRESSOR PC 101-0000-42600 0 $24.17 s0-00 PAID`BY'rp.�`;METHOD' r:la _• -r it T11 EC PTS CHECK# ;CLD Y DESCRIPTION'$h v, '':'.A000UNT. y ,:QTY. AMOUNT '�' PAID } PAID DATE - FURNACE 101-0000-42402 0, $35.75 $0.00 PAID BY i �i'r' t«r -'METHOD RECEIPT # max,"s 4t ' ,CHECK #" 7" CLTD By, i DESCRIPTION`°.+ ; ACCOUNT ;CITY- AMOUNT.. �. t .:' PAID r PAID DATE. 'FURNACE 101-0000-42402 0 $36.26 $0.00 BY " ''";" r I* W METHOD *_ =. , RECEIPT # � '. , . Y ,CHECK # CLTDSBY ` ; ,DESCRIPTION ''r. ;- F ::^ACCOUNTa QTYy t 4, AMOUNTS`, �.p PAID t, F, PAID DATE - FURNACE PC 101-0000-42600 0 $23.83 $0.00 wr PAID BY zx _• }, :. +-.. ,- a ,.: - E," r,"METHOD :,'RECEIPT:#`. r 4.' CHECK# CLTDBY," } Ji ..'" ` � DESCRIPTIOW'ly- i y - F' ACCOUNT - r QTY; AMOUNT . "~' MPAID,-� `�4 PAID;DATE 1 FURNACE PC 101-0000-42600 0 $24.17 $0.00 _PAID BY { � � �.: � i i.x: `METHOD ' `" � m RECEIPT#fir ' t.' `',J` CHECK # ;%s;, ,,:.CL TD-'B.Y _ it �' s DESCRIPTION yrs �. .-$ �` ACCOUNT -'� QTY AMOUNT PAID_- : , PAID ;DATE- VENT FAN 101-0000-42402 0 $23.84 $0.00 PAID?BYMETHOD 'RECEIPT #'�' CHECK # `` .i. .4. x CLTD BY' tr}x} DESCRIPTION '" 'All 'T ACCOUNT``"„ " "QTY " y i4M0UNT "a tr bxPAID }' ` PAID DATE VENT FAN 101-0000-42402 0 $24.18 $0.00 PAID BY aF.r r .. `� r - METHOD; t~RECEIP.Tr# 1'� ,r. CHECK #;¢ i CLTD'BY,-' DESCRIPTION ,'� 7 C . ` ACCOUNT r' _._ . _ - `QTY ,;'. AMOUNT - V ,. ., ; PAID ; PAID DATE -. VENT FAN PC 101-0000-42600 0 $9.54 $0.00 ' ' sPAID,BY} ss - �' fi '� = '+`' m METIiOD „f.. ` RECEIPT;#� '41 t CHECK # 'r CLTD BY�,r DESCRIPTION,*' �" w 3 `." r= ACCOUNT.' 'QTY "PAID'., ;=.fit t >PAID DATE VENT FAN PC 101-0000-42600 0 $9.66 $0.00 BY x- .r� ,� PAID # '.,� ., ;;.METHOD s,N,RECEIPT# y -'CHECK .ti., ^CLTDBY�' Total Paid for MECHANICAL: $307.24 $0.00 L ; ''DESCRIPTION ACCOUNT Y QTY s, r'AMOUNT '" PAID' a ' PAID DATE FIXTURE/TRAP 101-0000-42401 0 $71.52 $0.00 PAID BY} i ;:F 'st �1 �y�METHOD, :' 5' ►-+ � RECEIPT#x k t ' V CHECK#" CLTD BY ++ r :DESCRIPTION MOUNT fiPAID'i PAID:DATE FIXTURE/TRAP PC 101-0000-42600 0 $71.52 $0.00 PAIDBY .. , . . S' Or y x t:sCHECKRECEIPT# rF . CDBY. , ' r �r DESCRIPTION ? `. '_, Y �> ACCOUNT ~QTY ?: AMOUNT = y �xPA1D P - PAID DATE r a L�';' i }'{ GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $11.92 $0.00 L �, a RECEIPT #::; CHECK # CLTD BYG {, "f # [jESCRIP.,TION ' QTY f . - z AMOUNTt •p' K �PQID �, .5;, . PAIDDAT sir=ACCOUNT, . ,DATE GAS SYSTEM;•1-4 OUTLETS PC 101-0000-42600 0 $23.83 $0.00 'PAID BY x�; ,± rz s ;� 4 METHOD a RECEIPT:#.{ ., HECK*;," ; '�' CLTD'BYr + § ,€ , C • ��i'CGOUNT AM-- UNc TDESCRIPTION w P PA>I.D. DATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $11.92 $0.00 ':'METHOD {,+ " RECEIPT : x CLTD BYs; ,#f1 t „ I > - - J$ nL x�'r,. DESCRIPTION ;, .. r. *r' •. "1 ACCOUNT QTY'* PAID'Tti .PAID DATE'. - . iz 2 c y, WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 • $11.92 $0.00 '_ "i� i PAID i`:+`� METHOD r 4 ar•�,xw, W. RECEIPT.#�y fix' ` CHECK#�L x, - CLTD BY. ` -BY. `tr ,. E Y . Fes. � y,4 ,r. ` Total Paid for PLUMBING FEES: $202.63 $0.00 `tq. DESCRIPTION a,'ACCOUNT� AMOUNT,; LM`PAID `-.PAID,DATE' ks SMI -RESIDENTIAL' 101-0000-20308 0 $6.40 $0.00 �d �"?�'"' RAID, BY T �' METHOD ' a•"z i � RECEIPT # �� °s, At��CHECK #� -:e., bYe .�- .. u Total Paid forSTRONG MOTION INSTRUMENTATION SMt $6.40 $0.00 TOTALS:•0 • L �, a S . C A' • Description: 861SF CASITA ADDITION ADDITIONAL Type: BUILDING, RESIDENTIAL Subtype: ADDITION Status: APPROVED Applied: 8/15/2014 AOR Approved: 10/22/2014 MFA Parcel No: 775200013 Site Address: 55585 SOUTHERN HILLS LA QUINTA,CA 92253 Subdivision: TR 28341-1 Block: Lot: 13 Issued: Lot Sq Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $49,249.20 Occupancy Type: Construction Type: Expired: No. Buildings: 0 -D No. Stories: 0 No. Unites: 0 Details: ADDTION -861 SQ FT CASITA ADDTION. 2013 CALIFORNIA BUILDING CODES. RESUBMITTAL x ' 1 Applied to Approved',' T. ..FC Printed: Monday, October 27, 2014 3:39:14 PM 1 of 5 CNFSYSTEMS ADDITIONAL _ 1 ' CHRONOLOGY:TYRE t i + STAFF NAME �� ACTION DATE s' ' COMPLETION DATE NOTES - PLAN CHECK PICKED UP MARY FASANO 9/11/2014 9/11/2014 APPLICANT PICKED UP PLAN CHECK FOR REVISIONS RESUBMITTAL KAY HENSEL 10/9/2014 SENT TO PLAN CHECK KAY HENSEL 10/10/2014 10/10/2014 CONSULTANT "CONDITIONS x:CONTACTS a;, 1`,v:L:n e •'" ;r'"sr s - -: ,moi -_�� - Ad NAME cK 3 ADDRESSi `STATE. ZIP. :. ;P.HONE -,E` IL,''�i'. FAX MA �NAMETICPE Y .*tCITYc -.e , :rr �.rw_ ads $ rte._ , +v,. _t J. APPLICANT ROBERT PITCHFORD 77622 COUNTRY CLUB PALM DESERT CA 92211 DR. CONTRACTOR D & R REPAIR INC 44630 FRANKLIN LA QUINTA CA - 92253 COURT _ Printed: Monday, October 27, 2014 3:39:14 PM 1 of 5 CNFSYSTEMS Printed: Monday, October 27, 2014 3:39:14 PM 2 of 5 CSTWYSTEMS DESCRIPTION `ACCOUNT ; QTY AMOUNT .PAID 7 PAID, DATE ~RECEIPT # . CHECK# . METHOD =PAID BY ' .CLTD , ,. BY ADDITION, EA 101-0000-42400 0 - $122.98 $0.00 ADDITIONAL 500 SF ADDITION, EA 101-0000-42400 0 $124.72 $0.00 ADDITIONAL 500 SF , ADDITION, EA 101-0000-42600 0 $34.32 $0.00 ADDITIONAL 500 SF PC ADDITION, EA 101-0000-42600 0 $34.80 $0.00 ADDITIONAL 500 SF PC ADDITION, FIRST 100 SF 101-0000-42400 0 $120.12 $0.00 ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $0.00 ADDITION, FIRST 100 SF 101-0000-42600 0 $168.74 $0.00 PC ADDITION, FIRST 100 SF 101-0000-42600 0 $171.14 $0.00 PC Total Paid forADDITION: $897.65 $0.00 HOURLY PLAN CHECK - 101-0000-42600 2.25 $157.50 $0.00 YES Total Paid for BLDG CITY STAFF - PER HOUR: $157.50 $0.00 BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $6.00 ,$0.00 BSA: Printed: Monday, October 27, 2014 3:39:14 PM 2 of 5 CSTWYSTEMS _ _ "` _ ""+� _ .. ►' ACL-'�'-"G`�..'{'..=., d,'. ��u. ,-..^'.,.._.�;,a' c_ 0.-- "•- .. :.•.. "^'r .` DESCRIPTION .`. '.;,ry . :r :e.s�:�.F`? ,p'r G .z ACCOUNT ; „. Hw y 'QTY --' 'a.;�,�'=J AMOUNT ` ^ r...a- i i PAID � ,!' : : I DATE" 4��-' -7-11r RECEIPT # -��,�.s'. i CHECK # M � METHOD ,•'cS'. �- - � . -PAID BY^ . , �CLTD • -• rPAID U BY DEVICES, ADDITIONAL 101-0000-42403 0 $133.28 $0.00 DEVICES, ADDITIONAL 101-0000-42600 0 $33.60 $0.00 ' PC DEVICES, FIRST 20 101-0000-42403 0 $23.83- $0.00 DEVICES, FIRST 20 PC 101-0000-42600 -0 $23.83 $0.00 Total Paid for ELECTRICAL: $214.54 $0.00 CONDENSER/COMPRES 101-0000-42402 0 $35.75 $0.00 SOR CONDENSER/COMPRES 101-0000-42402 0 $36.26 $0.00 SOR CONDENSER/COMPRES 101-0000-42600 0 $23.83 $0.00 SOR PC CONDENSER/COMPRES 101-0000-42600 0 $24.17 $0.00 SOR PC FURNACE 101-0000-42402 0, $35.75 $0.00 FURNACE 101-0000-42402 0 $36.26 $0.00 FURNACE PC 101-0000-42600 0 $23.83 $0.00 FURNACE PC 101-0000-42600 0 $24.17 $0.00 VENT FAN 101-0000-42402 0 $23.84 $0.00 VENT FAN 101-0000-42402 0 $24.18 $0.00 VENT FAN PC 101-0000-42600 0 $9.54 $0.00 VENT FAN PC 101-0000-42600 0 $9.66 $0.00 Total Paid forMECHANICAL: $307.24 $0.00 FIXTURE/TRAP 101-0000-42401 0 $71.52 $0.00 FIXTURE/TRAP PC 101-0000-42600 0 $71.52 _ $0.00 GAS SYSTEM, 1-4 101-0000-42401 0 $11.92 $0.00 OUTLETS Printed:. Monday, October. 27;,2014 3: 5_39:14 PM 3 of 5 CR YSTEMS •J -v � � ?:e�TY� C. •4. .., .ti "yl*s-G.T•r"i.[� �1` N_ DESCRIPTION ACCOUNT, QTY 7 AMOUNT PAID PAID DATE RECEIPT # CHECK #, METHOD' iPAID BY CLTD., REVIEWS ..';_ACCO DATE, •BY: GAS SYSTEM, 1-4 101-0000-42600 0 $23.83 $0.00 NS 1ST REVIEW COMMENTS ATTACHED HARTUNG OUTLETS PC STRUCTURAL TOM 8/20/2014 8/29/2014 8/29/2014 REVISIONS REQUIRED WATER SYSTEM 101-0000-42401 0 $11.92 $0.00 TOM INST/ALT/REP 10/24/2014 10/10/2014 NON-STRUCTURAL WATER SYSTEM0 01-0000-42600 $11.92 $0.00 INST/ALT/REPPC BUILDING STRUC P/C TO YOUNG STRUCTURAL BUCKET B . 10/10/2014 Total Paid for PLUMBING FEES: $202.63 $0.00 SMI -RESIDENTIAL 7 101-0000-20308 o T— 7 $6.40 $0.00 Total Paid forSTRONG MOTION INSTRUMENTATION SMt $6.40 $0.00 TOTALS: $1,791.96 $0.00 INSPECTIONS HEDULED [ SEQID. INSPECTION TYPE, INSPECTOR SC COMPLETED RESULT REMARKS NOTES DATE DATE FINAL" - 5 - . . ' S * y" PARENT PROJECTS q: BOND INFORMATION Printed: M6nday, October 27, 2014 3:39:14, PM, 4, of 5;, �.s Y5i'Ehllf w REVIEWTYPi- REVIEWER 'SENT DATE DUE DATENOTES RETURNED_STATUS REVIEWS REMARKS , DATE, NON-STRUCTURAL TOM 8/20/2014 8/29/2014 8/27/2014 REVISIONS REQUIRED NS 1ST REVIEW COMMENTS ATTACHED HARTUNG STRUCTURAL TOM 8/20/2014 8/29/2014 8/29/2014 REVISIONS REQUIRED STRUCTURAL RFC 9/9/14. KH HARTUNG TOM 10/10/2014 10/24/2014 10/10/2014 NON-STRUCTURAL HARTUNG BUILDING STRUC P/C TO YOUNG STRUCTURAL BUCKET B . 10/10/2014 10/24/2014 10/10/2014 DUE 10/24 BOND INFORMATION Printed: M6nday, October 27, 2014 3:39:14, PM, 4, of 5;, �.s Y5i'Ehllf w Printed: Monday, October '27,,'2d'14 3-39-14- PM;5 of 5, SYS IFY ttachmahtT �7,CREATED 0& NERVW ES�lIO- � TINAVE'-r �jfAKIT,ENABLEDYp x, -2i L NS 1ST REVIEW 55-585 Southern DOC 8/27/2014 AJ ORTEGA COMMENTS - Hilk.docx, 0, DOC 10/27/2014 STEPHANIE KHATAMI SCHOOL FEES 55585 SCHOOL FEES 55585 0 I-- - I . - I SOUTHERN HILLS.pdf SOUTHERN HILLS.Pdf Printed: Monday, October '27,,'2d'14 3-39-14- PM;5 of 5, SYS IFY Woe a Valley. Vni ed chool District.:::This Box For District use only 83=733 Avenue 55;: Thermal; CA 92274 DEVELOPER FEES PAID (760) 398=5909 — Fax (760) 398-1224.' ' AREA: - ... .. .. .. 'AMOUNT ... ... LEVELONE AMOUNT::: :,- : LEVEL TWOAMOUNT:- :MITIGATION AMOUNT: COMMAND: AMOUNT: DATE: . ... .RECEIPT: .. .CHECK#:" ... .. .. ... .INITIALS.. ... CERTIFICATE OF COMPLIANCE (CaliforniaEducation Code 1.7620) . .. ... Project Nainei .. PGA West Stadium Course, Date: October 2.7, 2014. ' =Course Owner's Name:. :Thomas Boggs Phone No. '760-218.:6414 Project Addres§: 55585:Southern Hills; LaQuinta C. Project Description: Casita Addition—Sunri§e Agreement .: APN: .:77:5-200-013 :.:.: Tract, #:: :::.: Lot #'s: ;.... Type of Development:: Residential XX! Commercial Industrial: - Total Square Feet:ofBuilding Area: . 86F Certification.of:Applicaiit/Owners::The person signing certifies that th above information is'correct and makes thi§•statement under penalty o£perjury and further represents that he/she is. authorized to'gn on beh f of the owner/developer. : Dated:. October 27,1014— :Signature:. SCHOOL DISTRICT:'.S REQUIREMENTS.FOR THE ABOVE PROJECT HAVE BEEN:OR WILL BE.SATISFIED IN _:_ACCORDANCE WITH ONE. OF THE FOLLOWING:, . (CIRCLE ONE)... Education Code.: Gov. Code: Project Agreement Existing Not Subject to Fee ' ` 17620 65995 Approval Prior to 1%1/87: Requirement .. ... ... .:..Note: .. .. .. ... .. . . P ... .:..:.urs Number of Sq.Ft..:;.::_ 861 . Pursuant to AB.18i any;room additions: or enclosure f 500 ::: ;• sq. ft. or less are exempt from developer fees. Any. mobile Amount per Sq.Ft. homes being. relocated within:the same school district's_.;. • Amount Collected. $628.00 jurisdiction are. exempt from- developer fees.. - Building Permit Application Completed' Yes/No By: Elsa F.. Esqueda, Director: of Facilities and Maintenance, Certificate issued by: ' Laurie Howardj Secretary Signature: NOTICE OF 90 DAY.PERIOD FOR PROTEST OF FEES :AND. STATEMENT OF FEES ... Section 66020 of the Government -Code asserted by.Msembly Bill 3081, effectivejanuary 1, 1997, requires that this District provide.(1):a_written notice to the project-appellant;=at=th`e-time;of-payment-of school -fees; mitigation payment or other exactions ("Fees" ), of the 90 -day period to protest. the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with.section 66020 of the Government code and otlier'applicable law, this Notice shalCserve to »- -•--advise-you that the -90 -day protest period in -regard to such Fees or. the: validity thereof, commences with the payment of the fees or performance of any other •- —= requirements'asdescribed.in•section'66020 of the Government code: Additionally, the amount'of the fees imposed is as herein set forth, whether payable at this time or in whole or in. part. priorAo issuance of a. Certificate of Occupancy.. :As. in the latter, the 90 days.starts on the date hereof. This Certificate of -Coi ipliance:is-valid:foe;thirty(30) days from the-date'of issuance. -Extension will be: granted only for good cause, as determined by. the School District, and up to three (3) such extensions may be granted. " MV:c/mydocs/devfees/ceitificate of:complianca fonn updated 3:-2007 ... 11/2010 Bin # City of La Quinta Building &r Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico Bg8�7�1�•� La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: �7�+ CJ 5 I� Owner's Name: A. P. Number: % �% S ZOQ (� (� e,11 Address:S SQ , F-1(iLS Legal Description:L..OT- F q Z- 1 — City, ST, Zip: &LL9t Contractor: Tele phone: `76 6 s� 4 0 Z ><< Address: Project Description: City, ST, Zip: A ne• TeleP ho . State Lic. # : City Lic. #: Ateh-F*gr Designer: P'+ r-);:� Address:7 7 —6 ze- City., ST, Zip rlm,5� C C4 9 Zu Z Telephone:MN 8 4' State Lic. #:h x. :. Co T ccu anc struction e: O YP P Y• ect Pro a circle one): New Addn Alter Re Demo J P ) ' Pair Name of Contact Person: [Sq. # Stories: # Units: Telephone # of Contact Person: 7t4 ©Z� 4b" Z 56 Estimated Value of P. --2rojec 5CJ,,, �-- APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted _ �s g �" m nt Structural Calcs. Reviewed, ready for corrections D 1 la Ch2c ��pt . Truss Calcs. Called Contact Pcrs6 Plan Check Balance i Title 24 Calcs. Plans picked up 20 4 a Flood plain plan Pians resubmittedI { .��= .A L INTA Grading plan 2°" Review, ready for corrections/issue ��I,�: QWj� JjATY DEVE OPMENT Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Reyiew, ready for correctionsrissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue I School Fees VVI Total Permit Fees /acs d- � q�� /4e. 4�9 /°//p N'0�� -:2� . 10113 ^'/S 2 ' - •.v ` YOUNG ENGINEERING SERVICES w n r `n. 77-682 Country Club Dr. Ste. B, .Palm Desert, CA 92211 ph. (760) 772-•5107 fax (760) 345,-7620 Letter of 'Transmittal To: City of to Quinta Today's Date: 10-2.1-14 ' 78-495 Calle Tampico City Due Date: 10-24-14 La Quinta, CA 92253 Project Address: 55-585 Southern Hills Attn: Angelica Plan Check #: BRES 2014-1088 Submittal• 1st 4 t r '* ®' 2nd El 5th t ❑ 3rd ❑ .Other: We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) El You r Pickup Includes: , = •# Of % Descriptions: Includes: # Of Descriptions: Copies: Copies: ❑ Structural Plans ❑. 1. Revised. Structural Plans ® -1 Structural Calculations ❑ 1 Revised Struct. Calcs ❑ Truss Calculations Floor ❑ r 1 Revised Truss and Roof . ,. El Soils Report' �.Y ❑ . Revised Soils Report ® Structural Comment List/ ,❑ , 2 App roved Plans Responses ® 1 Redlined Structural Plans ❑ .: Approved Structural Calcs' ❑ Redlined Structural 'Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs' ❑ . Approved Soils Report El Redlined Soils Reports ❑ 1 Other: Truss Approval. Letter Comments: Structural content is approvable. If you have any questions, please call. J Time= 1.5 HR This Material`Sent for: ❑ ,Your Files. �,, , Per Your Request " ❑ Your Review ❑ Approval .. f 11 'Checking ❑ ' At the request of: Other: ❑ . By: Kathryn Samuels Palm Desert Office: ® (760) 772-5107 Other.: F-1 i 2 Gait Boggs Casita for D & R i https:Hmail.google.com/mail/?ui=2&ik=82acOb24fb&view=pt... MY Rob Pitchford <rob.pitchford@grmail.com>, Boggs Casita for Dw&'R-- ------ . ------ --� - – - - - - • — ----- ;f ----- . Adam Seuss <adam@iwglass.com> Tue, Oct 7, 2014 at 6:05 PM To: Rob Pitchford <rob. pitchford@gma il. com> Milgard white aluminum -new construction glazed with dual units clear low a sun coat max over clear,with argon gas. > Bedroom Qty. 1— 8050 XOX U Value .45, SHGC .24 Qty. 2 — 3050 SH U Value .46, SHGC .24 Sitting Room r Qty. 1—' 6050 XO U Value .45; SHGC .24 r Qty. 17 3040 Fixed U Value ':40, SHGC .26 Sink ' Qty. 1-4040 Fixed U Value,.40, SHGC .26 Thank You, Adam Seuss Indian Wells Glass and Mirror, Inc. - 75-080 St. Charles Place, Suite A Palm Desert, CA 92211 (760) 77970340 Fax (760) 779-0343 1 of 2 10/8/14, 11:00 AM ice: . - ,. r a+} t• vtjr� ` 3 Part Specification il •,r d : 'Aluminum' WINDOWS L DOk ,.y 1 as rl GENERAL NOTES TO SPECIFIER: k THIS SPECIFICATION SYSTEM HAS BEEN PREPARED TO ASSIST DESIGN PROFESSIONALS IN THE PREPARATION OF PROJECT OR OFFICE MASTER SPECIFICATIONS. IT FOLLOWS.GUIDELINES ESTABLISHED BY THE CONSTRUCTION SPECIFICATIONS INSTITUTE, AND THEREFORE MAY BE USED WITH MOST MASTER SPECIFICATION SYSTEMS WITH MINOR EDITING. EDIT CAREFULLY TO SUIT PROJECT REQUIREMENTS. MODIFY AS NECESSARY AND DELETE ITEMS THAT ARE NOT }' APPLICABLE. VERIFY THAT REFERENCED SECTION NUMBERS AND TITLES ARE CORRECT (NUMBERS AND TITLES _ REFERENCED ARE BASED ON MAST ERFORMAT 2004 EDITION:) THIS SECTION ASSUMES THE PROJECT MANUAL WILL CONTAIN COMPLETE DIVISION 1 DOCUMENTS INCLUDING 0125 13 — PRODUCT SUBSTITUTION PROCEDURES, SECTIONS 0133 00 — SUBMITTAL PROCEDURES, 01.62 00 — PRODUCT OPTIONS, 01 ,6600 = PRODUCT STORAGE AND HANDLING REQUIREMENTS, 0174 00 —CLEANING AND WASTE MANAGEMENT, 0177 00 = CLOSEOUT PROCEDURES, AND 01-78 00 —CLOSEOUT SUBMITTALS. CLOSE COORDINATION WITH DIVISION 1 SECTIONS IS' . REQUIRED. IF THE PROJECT MANUAL DOES NOT CONTAIN THESE -SECTIONS, ADDITIONAL INFORMATION SHOULD BE INCLUDED UNDER THE APPROPRIATE ARTICLES. THIS IS AN OPEN PROPRIETARY SPECIFICATION'ALLOWING USERS -THE OPTION OF. APPROVING OTHER MANUFACTURERS THAT COMPLY WITH THE CRITERIA SPECIFIED HEREIN. NOTES TO THE SPECIFIER ARE CONTAINED IN BOXES AND SHOULD BE DELETED FROM FINAL COPY.. OPTIONAL ITEMS REQUIRING SELECTION BY THE SPECIFIER ARE ENCLOSED WITHIN. BRACKETS, E.G. [35] [40] [45]. MAKE' APPROPRIATE SELECTIONS'AND DELETE OTHERS. • ITEMS REQUIRING ADDITIONAL INFORMATION ARE UNDERLINED BLANK SPACES, E.G. `" r OPTIONAL PARAGRAPHS REQUIRING'SELECTION OF.ONE OF THE OPTIONS ARE SEPARATED BY 'OR' WITHIN A BOX. E.G. r , BOLD FACE TYPE IDENTIFIES OPTIONAL PARAGRAPHS AND FEATURES THAT MAY BE INCUDEDrOR DELETED DEPENDING g UPON PROJECT REQUIREMENTS, CONVERT THE BOLD FACE TYPE TO REGULAR TYPE WHEN INCLUDING THESE PARAGRAPHS OR FEATURES. <: • b� REVISE FOOTER TO SUIT PROJECT/OFFICE REQUIREMENTS. ELECTRONICVERSIONS OF THIS SPECIFICATION UTILIZE AUTOMATIC PARAGRAPH NUMBERING. WHEN EDITING IS COMPLETE, DELETE ALL TEXT ON THIS PAGE, THEN REMOVE THE SECTION BREAK AT THE TOP OF THE NEXTPAGE,TO REMOVE THIS PAGE FROM THE DOCUMENT. " :_ • 1 Part Specification Windows .;• .Aluminum ALUMINUM WINDOWS' - 08.5113' 4 With the: thin lines that Migaed's Aluminum Windows provide, they are ideal for both new construction. as W411 as replacement: - This series of products provide an economical solution while providing architectural style`._ .. ` ` u. 71 y • k rift`. _'R, „ . Aluminum„ Windows z PART 1 —GENERAL41 1.01 +SUMMARY A. Section'Includes:,41 t .5, r T. Solid and tubular aluminum extruded windows of the following type(s):. Picture Window Series 710, 710S, 910C, 910S, 911C, 1185H, 1285H 'Casement Series 9100, 910S,,911C Awning Series 910C, 910S, 911C t + - Horizontal Slider Series 111 OH, 1110SH, 1180H,'1280H Vertical Slider Series 1510,1510S,1'580,,1680 Bay Window Series 1550 'Bow Window 'Series 1560 Radius ' Series R15, R15S, B. Related Sections: INSERT APPROPRIATE SECTION NUMBERS AND TITLES BELOW FOR WINDOW FEASHING AND INSTALLATION SEALANTS. it ► 3,<i� 08 32-03; Aluminum Sliding Dooms:. ' iNCEUDE'APPROPRIATEVIANGUAG_ E BELOW IF PRODUCTS SPECIFIED IN THIS SECTION ARE TO BE BID AS ALTERNATES -,OTHERWISE DELETE FOLLOWING PARAGRAPH. " t •.. Altei.«rn•.a �'k . . f' ates. ; • - � • ; 1. • `,.4.••i t. y 1. Reference Section 01 00 , 23 — Alternates. ' r ,� �, • ., r:• .. r ... !+. �„ ate' �! fit„ '''� . t '` Milgard Windows 3 Part Window Specification"- Aluminum Windows` n . `' Page 2 of 12 s.d E Aluminum Windows (continued) 4.,. i .. . 1.02 SUBMITTALS • . ' ' A. Reference Section 01 33 00 — Submittal Procedures; submit following items: 1. Product Data. t r 2. Shop Drawings: Include window schedule, window elevations, sections and details,. and multiple window assembly details. 3. Samples: a. "Color samples: Minimum 1x4 inch (25x100 mm) 'samples of Aluminum with Painted or anodized color. b. Glass, showing specified tint color. 4. Quality Assurance/Control Submittals: a. iQualifications: Proof of manufacturer's qualifications. tb. 'U -Factor and structural rating charts required for AAMA and NFRC labeling requirements. c. Installation Instructions — AAMA 2400 ("Mounting Flange Installation") or., AAMA 2410 ("Flush Fin Installation".). t B. Closeout Submittals: Reference Section 01 78 00 — Closeout Submittals; submit following items: 1. Temporary window labels marked to identify windows that labels were applied to. 2. Maintenance instructions. ' 3. Special Warranties. , 1.03 QUALITY ASSURANCE A. Overall Standards: Comply with ANSI/AAMA 101.I.S.2, except as otherwise noted herein. B. Qualifications: 1. Manufacturer Qualifications: a.. Minimum five years experience in producing aluminum windows of the „ 'type(s) specified. b. Member AAMA, NFRC. INSERT LOCAL REGULATORY REQUIREMENTS BELOW. . Milgard Windows 3 Part Window Specification — Aluminum Windows -Page 3 of 12 i Aluminum Windows (continued) C.. Regulatory Requirements: ' D. Certifications for insulated glass windows: 1. AAMA: Windows shall be Gold Label certified with label attached to frame per AAMA requirements. " 2. NFRC: Windows shall be NFRC certified with temporary U -factor label applied to: glass and an NFRC tab added to permanent AAMA frame label. 1.04 DELIVERY, STORAGE AND HANDLING A. Reference section 01 66 00 - Product Storage and Handling Requirements. B. Follow manufacturer's instructions on label applied to windows. 1.05 WARRANTY. SELECT "RESIDENTIAL" WARRANTY BELOW FOR OWNER OCCUPIED SINGE FAMILY RESIDENTIAL -AND OWNER OCCUPIED CONDIMINIUM PROJECTS. SELECT"COMMERCIAL WARRANTY FOR NON -OWNER OCCUPIED CONDOMINIUMS, COMMERCIAL, AND MULTI -FAMILY PROJECTS. A. Residential Special Warranty: 1. Lifetime guarantee to original owner.. , 2. Transferability: + u a) Permit unlimited transfer of ownership in first ten years. b) Upon first transfer of ownership, guarantee period, shall become ten years;," from date of original purchase. ,. 3. Guarantee windows against defect in materials and work manship including,costs for ; parts and labor. } OR B. Commercial Special Warranty: " 1'. 10 -year guarantee. 2. Guarantee windows against defects in manufacturing and workmanship including costs for parts and labor..: - + Milgard Windows 3 Part Window Specification — Aluminum Windows PageM14 of: 12 ' Aluminum Windows�(continued) PART 2 — PRODUCTS 2.01 MANUFACTURER . A. Milgard Manufacturing, Inc.. Tel: 1.800.MILGARD (645-4273) �. 1010 54th Avenue East (253) 922-2030 Tacoma, WA 98424 Fax: (253) 926-0848 , 4 Web: ' milgard.com :, INSERT NAME, ADDRESS AND PHONE NUMBERS OF MANUFACTURER'S REPRESENTATIVE'BELOW 1. Manufacturer's Representative: Tel: ' y Fax: Email: B. Window Series:' Milgard Aluminum Windows C. Substitutions: Reference Section 01 25 13 — Product Substitutions Procedures. 2.02 -MATERIALS. A. Aluminum: Comply with requirements of AAMA/WDMA/CSA 101/I.S.2/A440-05, 6063-T5 •temper for strength, corrosion resistance and application of required finish. - z '113. Extruded frame members are to be .060" in thickness for structural walls. VERIFY THAT WINDOW FLASHING MATERIAL AND INSTALLATION SEALANT IS SPECIFIED IN APPROPRIATE SECTIONS. 2.03 GENERAL PERFORMANCE REQUIREMENTS:, A. Thermal Performance: Comply with NFRC 100. B. Air Leakage, Water Resistance, Structural Test: Comply with ANSI/AAMA 101/I.S.2. C. Forced -Entry Resistance: Comply with ASTM E 588. • r Milgard Windows 3 Part Window Specification —Aluminum Windows Page 5°of 12 4 • �. .. .J , Aluminum Windows (continued) 2.04 WINDOW TYPES: + SELECT FOLLOWING WINDOW_ TYPES AND RELATED NAIL FIN/MOUNTING STYLE BASED ON PROJECT REQUIREMENTS. DELETE WINDOW TYPES NOT USED. A. Picture Window and Radius — [710 Series, 1 inch (25mm) nail .fin setback] [710S Series, 1 3/8 inch (35mm) nail fin setback with stucco key] [ 910C Series, 1 i6ch.(25mm) nail fin setback] [ •910S Series, 13/8" (35mm) nail fin setback with stucco„key] [ 911C Series, block frame (no nail fin] [R-15 Series, 1 inch (25mm) nail fin setback] [R-15S Series; 1 3/8” (35mm) nail fin setback with stucco key] [1185H Series, block frame (no nail fin)] [1285H:Series,`Z-bar flush fin]: 1.' Frame: a: 710.& 710S Series, 2 1/16" (52mm) & 2 3/8" (60mm) b. 910C Series, 2 1/16" (52mm) C. 910S Series, 2 7/16" (62mm) ' d. 911 C Series, 1 '/4" (32mm) ' e. R15 & R15S Series, 2 1/16" (52mm) & 2 3/8" (60mm) f. 1185H & 1285H Series, 2 1/16" (52mm) 2. Sightlines: a. 1185H & 1285H Series, equal to the horizontal slider and single hung 3. Performance Class: y a. 710 & 710S Series, 95'/" x 71 %2" and smaller: FW-HC40 ti. 910C, 910S & 911C Series, 95'/2" x 71''/2" and smaller: FW-HC45 c. R-15 & R-1 5S Series, 71 '/2" x 71 '/2"`and smaller:'FW-HC40 - d. ,1185H Series, 71 '/2" x 71 '/2" and smaller: FW-HC45 e. 1285H Series, 71 '/2" x 71 '/z" and smaller:, FW-HC40 B. , Horizontal Slider. - [111 OH Series, 1 inch (25mm) nail fin setback]'[1110SH Series, 1 3/8 inch (35mm) nail fin setback with stucco key] [1180H Series, block frame (no nail fin) ] [1280H ' Series, Z-bar flush fin]: 1. Frame: ' a, 1111OH& 1110SH Series, 2.1/16" (52mm) & 2 3/8" (60mm) b' 1180H & 1280H Series, 2 1/16" (52mm) " 2. Sash: Depth of 1 1/8" (29 mm), hollow aluminum extrusion. A Milgard Windows 3 Part_Window Specification — Aluminum Windows Page 6 ofi 12 3. Sightlines: Non -equal sightlines between sash and fixed glass. 4. Performance Class: a. 119'/" x 71 '/2" Double Vent, 36". vent set: HS-LC25. 5. Hardware: a. Nylon rollers with stainless steel axles, aluminum: integral'rhonorail track. b.. ,Single pull rail on meeting rail sash. C. 'Automatic, spring loaded, height adjustable positive lock. 6. Weatherstripping: Fin seal polypropylene pile. C. Single Hung — [1510 Series, 1 inch (25mm) nail fin setback] [1510S Series, 1 3/8 inch. (35mm) nail fin setback with stucco key] [1580H Series, block frame (no nail fin) ] [1680H Series, Z -bar flush fin]: 1. Frame:, a. 1510 & 1510S,Series, 2 1/16" (52mm) & 2 3/8° (60mm). b. 1580H & 1680H Series,.2 1/16" (52mm) 2. Sash: Depth of 1 1/8" (29 mm), hollow aluminum profile. 3. Sightlines: Non -equal sightlines between sash and fixed glass. . 4. Performance Class: a. 47 1/2" x 83'/2" and smaller: H-LC25. 5. Hardware: a. Concealed block and tackle balancer. b. Single pull rail (sash lifts) on -meeting rail sash. c. ', Automatic, spring loaded, height adjustable positive lock. 6. Weatherstripping: fin seal polypropylene pile. D. Casement — [910C Series, 1 inch (25mm) nail fin.setback] [910S Series, 1 3/8 inch (35mm) nail fin setback with stucco key] [911 C Series, block frame (no nail fin)]: - 1 Frame: a. 910C Series, 2 1/16" (52mm) b. 910S Series, 2 7/16" (62mm) c. 911C Series, 1,%" (32mm) 2. Sash: Depth of 1 5/16" (33mm), solid aluminum extrusion: Milgard Windows 3 Part Window Specification — Aluminum Windows Page 7 of 12 3.. Performance Class: a. 95'/" x 59 %2" Double Casement with center picture window, :32 vent set:,,C- C30. k 4. Hardware: ' a. Operators will be of single push arm design driven 'by a hand crank: �- °Constructed of hardened steel worm and gearing andhigh-pressure zinc .T alloy die castings with high-strength plastic trim, cover. b. "Cam style locking mechanism with -latch on jamb. C. -Tension adjustable hinge. ` 5. Weatherstripping; Dual durometer vinyl bulb seal. E. Awning - [910C Series, 1 inch (25mm),nai[fin setback] [910S Series,,1 3/8 inch (35mm) Pail fin setback with stucco key] [911 C Series, block frame (no nail fin)]: i 1. Frame: , a. 910C Series, 2 1/16" (52mm) ` b. 910S Series, 2 7/16" (62mm) c. 911 C Series, 1 %" (32mm) 2. Sash: Depth of 1 5/16"_(33mm), solid aluminum extrusion. . 3. Performance Class: , a. " 471/2" x 83 Y2" Bottom Awning, 36" barset: AP -C30. 4. Hardware: a. , Operators will be of combined push arm and drag arm/link design driven by a hand crank. Constructed of hardened steel worm and gearing and high -pressure zinc alloy die castings with high-strength plastic trim cover. b. ,,, :Cam style locking mechanism with latch on jamb. c. Tension'adjustable hinge. Y 5. Weatherstripping: Dual durometer vinyl bulb seal. F. Bay Windows - [1550 Series, 1 inch (25 mm) nail fin setback]: 1. Frame: Depth of frame is 2 1/16" (52mm) r 2. Unit configuration and window types as shown on drawings; mulled together to form' single window unit. 3. Assembly posts at 45 degrees. y G. Bow Windows - [1560 Series, 1 inch (25 mm) nail fin setback]: Milgard Windows 3 Part Window Specification — Aluminum Windows Page 8 of 12 1. Frame: Depth of frame is 2 1/16" (52mm) 2: Unit configuration and window types as shown on drawings; mulled together to form single window unit. 3. Assembly posts at 13 degrees. - SI ". Aluminum Windows (continued) i 2.05`v GLAZING A. - Insulated Glass Units: ASTM E 774, Class A, 3/4 inch (19rrim) thick overall except 71,0 and 710S which are 1 inch (25mm) thick. j 1. Glazing Type: Clear/Clear Clear/SunCoat®,Low=E Clear/SunCoat® L'ow E .ar tonr. ` gas filled] [Clear/SunCoatMAXTm Low -E] [Clear/SunCoatIVIAXTM Low -E, argon gas. filled] [Clear/Hardcoat Low -E] [Clear/Hardcoat Low -E, argon gas filled]. WARM EDGE SPACERS ARE NOT AVAILABLE ON SOME UNITS 'INCLUDING CERTAIN OVERSIZE UNITS, RADIUS AND GABLED UNITS.'..p, Jr , 2.. Spacer Bar: [Warm edge steel spacer] [Aluminum box spacer] [Warm edge foam"' spacer]!, MOST COMMON TYPES OF INSULATED UNITS ARE INCLUDED ABOVE, BUT SEVERAL OTHER TYPES INCLUDING TINTED,»,a REFLECTIVE, HEAT STRENGTHENED,�TEMPERED, OBSCURE, WIRE, AND LAMINATED ARE AVAILABLE FOR SPECIAL APPLICATIONS. SELECT DESIRED TYPES FROM MILGARD WEBSITE milgard.com/architects AND SPECIFY IN LIEU;;OF, OR IN ADDITION, TO THE ABOVE WITH ALL NECESSARY CRITERIA SUCH AS OBSCURE PATTERNS. IF MORE THAN'ONE TYPE OR GLAZING IS REQUIRED FOR THE PROJECT, BE CERTAIN THAT TYPE FOR EACH .WINDOW IS CLEARLY NOTED ON, DRAWINGS OR IN WINDOW SCHEDULE.' 4 OR B.• Single Pane Glass:, 1. Glazing) Type: [Clear] [Solar Bronze] [Solar Gray] [Hardcoat Cow -E] [Solar Cool t { Bronze] [Solar Cool Gray]. ' MOST COMMON TYPES OF SINGLE PANE GLASS ARE INCLUDED ABOVE, BUT SEVERAL OTHER TYPES INCLUDING REFLECTIVE, HEAT STRENGTHENED, TEMPERED, OBSCURE, WIRE, AND LAMINATED ARE AVAILABLE FOR,SPECIAL ' APPLICATIONS. SELECT DESIRED TYPES FROM MILGARD WEBSITE milgard.com/architects AND SPECIFY IN LIEU OF, OR IN ADDITION, TO THE ABOVE WITH ALL NECESSARY CRITERIA SUCH AS OBSCURE PATTERNS. IF MORE THAN'ONE TYPE OF GLAZING IS REQUIRED FOR THE PROJECT, BE CERTAIN THAT TYPE FOR EACH .WINDOW IS CLEARLY, NOTED ON DRAWINGS OR IN WINDOW SCHEDULE. + 2.06 'DIVIDED LITE GRIDS '" "�' • -` ,•` VERIFY. THAT DESIRED GRID PATTERNS, IF ANY, ARE SHOWN ON THE DRAWING., CERTAIN GRID PATTERNS MAY NOT BE AVAILABLE WITH ONE OR THE OTHER BAR TYPES IN THE FOLLOWING PARAGRAPH - CONSULT MILGARD FOR UNUSUAL . DESIGN APPLICATIONS. GRIDS ARE NOT AVAILABLE FOR SINGLE PANE GLASS WINDOWS. ' A. . [5/8 inch (16 mm) wide flat, grids between the glass that are color matched to frame and sash] '[1,1/16 inch (27 mm) wide sculptured, grids between the glass that are color matched • to frame and sash] t Milgard Windows '3 Part Window Specification Aluminum Windows Page 10 of 12 - i Aluminum Windows (continued) 2.07 , INSECT SCREENS A. Provide tight-fitting screen for operating sash with hardware to allow easy removal. 1. Screen Cloth: Charcoal colored fiberglass mesh. 2. Frame: . a. Cambered formed aluminum with rigid plastic corner keys. b. Pull tabs for removal. 2.08 FABRICATION ti 4 A. Fabricate frames and sash with mechanically joined corners. Corners are fastened with corrosion resistant screws and sealed with an acrylic sealant. - ,C. All fixed glass is exterior'=glazed and all sashes-,are marine glazed with flexible PVC glazing. The fixed glazing shall be removed without disassembly of a sash. The vents will need to be` disassembled to replace the glazing. 2.09 FINISHES A. Frame and Sash Color: [White] [Tan] Painted Exterior Finish: Equaling 0.3 mils dry film thickness to AAMA 603.8-92. B. Frame and Sash Color: [Bronze] [Clear] Anodized Exterior. Finish: Provide-AA-C22-A32„ Class II Bronze or AA-C22-A31 Class II Clear finish, minimum 0.4 mils thick, electrolytically deposited color anodized finish. - C. Color match screen frame to window frame and sash color. 2.10 SOURCE QUALITY CONTROL r A. Windows inspected in accordance with manufacturer's Quality Control Program as required by AAMA Gold Label certification. - PART 3 - EXECUTION 3.01 EXAMINATION A. Examine openings in which windows will be installed. 1. Verify that framing complies with AAMA 2400 ("Mounting Flange Installation") or AAMA2410 ("Flush Fin Installation"). 2. Verify that fasteners in framed walls are fully driven and will not interfere with window 'installation. B. Coordinate with responsible entity to correct unsatisfactory, conditions: Milgard Windows 3 Part Window Specification —Aluminum Windows Page 11 of.12' Aluminum Windows (continued) . C. Commencement of work�by installer is acceptance of substrate conditions F 3.02 INSTALLATION .. INSTALLATION; INSTRUCTIONS (AAMA 2400) ARE ADEQUATE FOR NORMAL INSTALLATION CONDITIONS IN FRAMED CONSTRUCTION. MASONRY WALLS AND UNUSUAL CONDITIONS MAY REQUIRE ADDITIONAL INFORMATION IN THIS ARTICLE. A. Install windows in framed walls in accordance with AAMA 2400 ("Mounting Flange Installation") or AAMA 2410 ("Flush Fin Installation"). B. Do not remove_ temporary labels. C. Install insect screens on operable sash. ' 3.03 CLEANING A. Reference Section 01 74 00 —Cleaning and Waste Management.. r B. Remove temporary labels and retain for Closeout Submittals. " C. Clean soiled surfaces and glass using a mild_ detergent and warm water solution with soft, clean cloths. END OF SECTION ' This specification was prepared by Milgard Manufacturing, Inc. Comments or suggestions for improvement should be addressed to Milgard at the address in Article 2.01 A: Issue Date: October 31, 2007' Milgard Windows' 3 Part Window Specification — Aluminum Windows Page 12 of. 12 •b'Z CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Boggs.Casita Calculation DatelTime: 12:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Boggs Casita-Pitchford-14.xml CF1 R -PRF -01 Page 1 of 7 .GENERAL INFORMATION 01 Building Complies$ kith-Computer_Perfo'�maniie` .. `, •. ;r .'' 02 This building incorporates features that requiie fiend testing aihd/or.'venficationA,by a -certified HERS:rat,& undeF the supervision of a CEC-approved HERS provider. 01 Project Name Boggs Casita 04 05 06 02 Calculation. Description Title 24 Analysis Energy Use Standard (kTDV/ft) Design Proposed Design 03 Project Location 55-585 Southern Hills Space Heating 4.77 5.98 04 A City La.Quinta 05 Standards Version Compliance 2015 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (650) 08 Climate Zone CZ15 09 _ Software Version EnergyPro.6.3 10 Building Type Single Family 11' Front Orientation (deg/Cardinal) 195 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 861 15 Number of Zones 1' 16 Slab Area (FT2) '861 17 Number of Stories 1 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 Glazing Percentage (%) 25.8% COMPLIANCE RESULTS 01 Building Complies$ kith-Computer_Perfo'�maniie` .. `, •. ;r .'' 02 This building incorporates features that requiie fiend testing aihd/or.'venficationA,by a -certified HERS:rat,& undeF the supervision of a CEC-approved HERS provider. 03 This building incorporates one 0"r ore Special"Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use Standard (kTDV/ft) Design Proposed Design Compliance Margin Percent Improvement Space Heating 4.77 5.98 -1.21 -25.4% Space Cooling 175.19 175.45 -0.26 -0.1% IAQ Ventilation 2.00 2.00 0.00 0.0% Water Heating 22.07 18.80 3.27 14.8% Photovoltaic Offset --- 0.00 0.00 –– ComplianceEnergyTotal .204.03 202.23 -1:80 — 0.9%. BUILDING & SAFETY DEPT. -krl, ROV FOR CONSTRUCTION RECEIVED DAT IWI.Q /_/ BY 7 -,*I 0 C T 0 9 2014 Registration Number: 214 N00712648-000000000-0000 Registration Date/Time: 2rOTE;2r: CITY OF TA CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-09042014-650 4' 1 T Report GentbOAdff ff- EI'MENT D CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Boggs Casita Calculation Date/Time: 12:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input.File Name: Boggs Casita-Pitchford-1,4.xml REQUIRED SPECIAL FEATURES The following are features thafmust be installed as condition,for meeting the modeled energy'performance for this computer analysis. , • Ducts with high level of insulation CFI R -PRF -01 Page 2 of 7 PROJECT HERS FEATURES The following are project -level features thatmust be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below, requre field verification by a certified HERS Rater. IAQ mechanical ventilation ENERGY DESIGN RATING This is the. sum of the annual TDV�energy consumption for energy use components included in the performance compliance approach for the Standard•Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable, energy system. Reference Energy Use 2 -' 1P Energy, DesignRating �,.: s Margin.. ". Percent- Improvement Total Energy (kTDWf2)' _ 275.88 r•,� s. 27.4 08 �', 1.80 0.7% ' includes calculated Appliances and Miscellaneous Energy Use�tAME1-7 ` . �e,7777;73N.& `— 6. BUILDING - FEATURES INFORMATION14*' ' T.• b 01 02 axsf� ` ...: . 03,: a sib zas ;? 04 fi _05'" 04 ' O6 07 Project Name , .:Number of Dwelling ' Conditioned -Floor Area (sft) Units . 4` Number of Bedrooms Number of Zones Number Ventilation Cooling Systems Number of Water, Heating Systems Boggs Casita 861, 1 3 1 1 1 ZONE INFORMATION 01 02 03 04 ' 05 06. 07, Zone Name' Zone Type HVAC System Name Zone Floor Area– (ft2) Avg. Ceiling Height - - +Water Heating System 1 _ Water Heating Systemi2 Casita ' Conditioned HVAC .1 casital 861 14 DHW Sys 1 f Registration Number: 214-N0071264B-000000000-0000 Registration Date/Time: 2014-10-08 13:22:55 HERS Provider: CaiCERTS inc. CA Building Enefgy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014-650 Report Generated at: 2014-10-08 12:05:41 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Boggs Casita Calculatiori Date/Time: 12:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Boggs Casita-Pitchford-14.xmi CFI R -PRF -01 Page 3 of 7 OPAQUE SURFACES -- -_ -�, -_ - _ '-.. _ - _ �, _ . _ �... _ . _ .: - - _ �_ - _ - -_ __ �_ -- • -- .- - - - - - 01 02 03 04 05 06 07: 08 Name • Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ft) Tilt(deg) 15d Wall, Casita ; R-21 Wall (W.21.2x6.16) 15 Back 600 52 90 . 105d Wall Casita R-21 Wall (W.21.2x6.16) 105 Right 760 57.8 90 195d Wall Casita R-21 Wall (W.21.2x6.16) 195 Front 600 72 ` . 90 285d Wall Casita R-21 Wall (W.21.2z6.16) 285 Left 760 40.2 90 Roof Casita R-38 Roof Attic "' 4.9 0.51 861 NEW 6 Window ATTIC 01 02 63 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier. Cool Roof Attic Attic Roof Cons - : • 3 0.1' 0.85 No No WINDOWS 01 02 y" ��;�03' :`+�'}QS 06 07 08 09 10 Name Type Width(ft Height r entation_ A- zirm: uth) MuIt *of r- _ Area (ftZ) U -factor SHGC Exterior Shading Window. '.:Surfaia.,_(O- 5d,Wll'(Bak- 1NEW 36.0 0.51 0.30 NEW.2 Window }15d Wall (Back -15) - - 1 16.0 0.51 0.30 NEW 3 Window 105d Wall .(Right -1 05) . --_ -- 1 24.0 0.51 0.30 NEW 4 Window 105d Wall (Right -105) --- - 1 4.9 0.51 0.30 NEW 5 Window 105d Wall (Right -105) = ---- 1 "' 4.9 0.51 0.30 NEW 6 Window 105d Wall (Right -105) - -.. -- 1 _ 24.0 0.51 _ 0.30. _ NEW 7. 'Window 195d Wall (Front -195) - - - 1 24.0 • 0.51 0.30 NEW 8 Window 195d Wall (Front -195) -- -- 1 24.0 0.51 0.30 NEW 9" Window 195d Wall (Front -195) -- ----' 1 24:0 0.51 0.30 NEW 10 Window 285d Wall (Leff -285) - --- 1 20.1 0.51 0.30 NEW 11 Window: 285d Wall (Left -285) - --• 1 20.1 0.51" 0.30 Registration Number: 214-N0071264B-000000000-0000 Registration Date/Time: 2014-10-0813:22:55 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014-650 HERS Provider: CaICERTS inc. Report Generated at: 2014-10-08 12:05`41 .1 - CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Boggs Casita Calculation Date/Time: 12:04, Wed, Oct 08, 2014 Page 4 of 7 Calculation Description: Title 24 Analysis Input File Name: Boggs Casita-Pitchford-14.xm1 OPAQUE SURFACE CONSTRUCTIONS_ 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R -value Assembly Layers Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value 2x4 Top Chord of DHW Heater 1 Cavity/Frame: no insul. /2x4 Top Chrd Small Storage 50 0.66 Roof Truss @ 24 in. 0 Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-9.1 / 2x4 R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @.16 in. O.C. R 38 Over Floor Joists: R-28.9 insul. • Inside Finish: 'Gypsum Board -Cavity / Frame: R-21 / 2x6 R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @•16 in. O.C. R 21 Exterior Finish: Wood Siding/sheathing/decking SLAB FLOORS 01 .01' 02. .3 03 04 05 06 07 Name Zone k, Area (ft2) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated Covered Slab,. Casita ,�w 861 .J86 -k. None 0.8 No BUILDING ENVELOPE -HERS VERIFICATION A63 04 01 se Quality Insulation Installation (Qll) —Quality Installation of Spray F6_im insulation_. Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required — 1, WATER BEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 - ' ' Pipe Insulation, -All Lines 1 - - 0.0%" WATER HEATERS 01 02 03 04 -05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.66 40000-Btu/hr 0 0 Registration Number: 214-N0071264B-000000000-0000 Registration Date/Time: 2014-10-08 13:22:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014-650 Report Generated at: 2014-10-08 12:05:41. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD - Project Name: Boggs Casita Calculation Date/Time: 12:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Boggs Casita=Pitchford-14.xmi CF1 R -PRF -01 Page 5 of 7 WATER HEATING -HERS VERIFICATION,,, V 01' 02 03 04 05 ` 06 - 07 Name Pipe Insulation Parallel Piping, Compact Distribution Point -of Use , Recirculation with' Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a SplitAirCond - Split air conditioning n/a HVAC SYSTEMS 01 02 03 04 05 06 07, Verified Airflow Efficiency Heating System Cooling System - Verified Refrigerant Charge Name System Type EER SEER. Zonally Controlled Compressor . HERS Verification Distribution SplitAirCond - Split air conditioning Floor Area Name. System Type Name Ducted. Name Ducted System Fan System Served HVAC 1 casital • Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 • 861 HVAC- HEATING SYSTEMS .. Name4r ` T re' Efficient Heating Component 1igy# p ��`'kCntrlFurnace - Fuel -fired -central furnace' , 80 AFUE. " — -*-ME8�6i�i*"vP�."Se:^r W +@PC��s._. �":aE�A'i�"�tf' �Sa�^•aw!.r"!►7T P -1I ,X. ' HVAC - COOLING SYSTEMS y 01 `� '' 02- 03 04 OS 06 07 • Name Verified Airflow Efficiency Verified EER Multi -speed Verified Refrigerant Charge Name System Type EER SEER. Zonally Controlled Compressor . HERS Verification Cooling Component 1, SplitAirCond - Split air conditioning 13.7 ;' 17.7 No No Cooling Component , system 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 • Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Required • Required Required Registration Number: 214-N0071264B-000000000-0000 Registration Date/Time: 2014-10-08 13:22:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014-650 Report Generated at: 2014-10-08 12:05:41 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Boggs Casita Calculation Date/Time: 12:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Boggs Casita-Pitchford-14.xml CFI R -PRF -01 Page 6 of 7 HVAC -:DISTRIBUTION SYSTEMS, - _ � .: _ _ y .., . -- ' •_ - - _ =='- -' , - ,'� _ - • - =-� .. �- _ _ _._ _ - - -- . _ _ - - - - _ _ 01 02 03 04 05 06 '07 08 Verified Duct Location Verified Duct Design . Return Supply Air Distribution System 1 -hers -dist Required Supply Duct Not Required Not Required Not Required Default Name Type Duct Leakage Insulation R -value Location Return Duct Bypass Duct HERS Verification Air Distribution Air Distribution System 1 Ducts located in attic Sealed and tested 8 Attic Attic None System 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01- . - 02 03 04, 05 06 Name ' Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design . Return Supply Air Distribution System 1 -hers -dist Required 6.0 Not Required Not Required Not Required HVAC - FAN SYSTEMSu .01 02 ; 03 04 Name1- # Type; ;fj t;<F an Power (Watts/CFM) HERS Verification HVAC Fan 1�Sirigle Speed FSC Furnace Fa`n` f 0.58 Required wr�vaar c�w�ra� oma®s wr�c�: ��+racs�rr+�.,,r.�� ��r�: ri�:�• HVAC FAN SYSTEMS - HERS VERIFICATION' 1'-*, 01 _..'" ^i. 02 .03 Name'. VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 IAQ (Indoor Air Quality). FANS - 01 - - - - 02 - 03 -. -- - - -_ 04 O5. 06 - - Name IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt .38.61 0.25 Default 0 Required COOLING VENTILATION 01 02 03 04 05 Name - Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans. HERS Verification WH Fan 1 61 0.52459 1 Required Registration Number: 214-N007126413-000000000-0000 Registration Date/Time: 2014-10-08 13:22:55 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014-650 HERS Provider: CaICERTS inc. Report Generated at: 2014-10-08 12:05:41 k% CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE. METHOD Project Name: Boggs•Casita Calculation DatefTime: 12:04, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis ; Input File Name: Boggs. Casita-Pitchford-14.xm1 CF1 R -PRF -01 Page 7 of 7 + r.. k DOCUMENTATION,AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance'documentation is accurate'and complete:_,A. Documentation Author Name: Documentation Author Signature: = " ' ' Tiw.�coZY'`,. � � "`•ti' Tim Scott . _ _ Company: Signature Date: Scott Design and Title 24, Inc.: J. 2014-10-08 12:07:50 - L i Address: .CEA/HERS Certification Identification (if applicable): . C + r `• 4 77085 Michigan Drive City/State/Zip:J Phone: , Palm Desert, CA 92211 (760) 200-4.780 RESPONSIBLE PERSON'S DECLARATION'STATEMENT - I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. - 3. The building design features or system_design"features identified,on-this Certificate of,.Compliance-are-consistent-with the information provided on other applicable compliance documents, worksheets,, calculations, plans and ecifications subm tt d to the enforcement ag`e cy f r app oval w h�thi building permit application. Responsible Designer Name:gi, - Responsible Designer Signature: 1+ Robert Pitchford 'c�� `- a .,. _� _� ,#.M ,. Company: Date Signed:" Robert A. Pitchford Design &.Drafting 2014-10708 13:22:55 Address: f License:: 77-622.Country Club Drive, Suite O - NA City/StatelZip: Phone: P I D ese rt CA 92211 - (760) 346 2856 Digitally sigried by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way, implies Registration Provider responsibility for the. accuracy of the information. Registration Number: 214-N0071264B-000000000-0000 Registration Date/Time: 2014-10-08 13:22:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-09042014-650 Report Generated at: 2014-10-08 12:05:41 WWO� �3�3a �,.1.INn 17 1N3 dl� Inb 40 a3n13�3� ..BUILDING., ENERGY ANALYSIS. REPORT I OT: M., } • PROJECT: Boggs Residence Casita 55-585 Southern, Hills La Quinta,' CA 92253 • Project Designer: Robert A. Pitchford Design•• and Drafting . 77-622 Country Club STE O Palm Desert, CA 92211 (760).346-2856 t by -Report Prepared Jon Scott Scott Design and Title:24, Inc, 77-085 Michigan Drive Palm .Desert, CA 92211 '(760) 200-4780 EIE -Job Number:, ,. OCT 092014 CITY OF LA QUINTA Date. COMMUNITY DEVELOPMENT. a 10/8/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and,i§ • authorized by the California Energy Commission for,use with both the Residential and Nonresidential 2013 Building Energy Efficiency Staridards. ,This program'developed by EnergySoft,:LLC-www.energysoft.com. :Mayr• Ene Pro 6:3b ,Ene Soft User Number. 6712 .. ID t i TABLE OF CONTENTS� Cover Pagel. Table of Contents f 2 Form Cr-1R Certificate of Compliance' Form RMS-1 Residential Measures Summary 10 Form `MF-1 R-Man'dat`ory Measures Summary. HVAC System Heating and Cooling Loads Summary. 14` 'Room Load Summary ; 15" Room Heating Peak toads ! 16 Room Cooling Peak Loads 17 f ' ri Illi. ,,, - . '! • - i - at EnergyPro 6,3 by EnergySoft Job Number: ID: i User Number. 6712 t} CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Boggs Casita Calculation Date/Time: 11:56, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Boggs Casita-Pitchford-14.xml CF >�F-01 Pt 1 of`7 GENERAL INFORMATION 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater, under the supervision of a CEC-approved HERS provider. 01 Project Name Boggs Casita 04 05. 06 07 02 Calculation, Description :Title 24 Analysis Standa&T Proposed Compliance De gn Design Margin Percent Improvement 03 Project Location 55-585Southern Hills -25.4% Space Cooling. 04 A City La Quinta.. of : Standards Version 'Compliance 2015' 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (650) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 16 Building Type Single Family 11 Front Orientation (deg/Cardinal) 195 12 Project Scope Newly Constructed 13 Number of Dwelling Units •1 14 Total Cond. Floor Area (FA 861 15 Aqw Number of Zones 1 16 Slab Area (FTZ) 861 17(jv Number of Stories 1 18 Addition Cond. Floor Area ,NA 19P Natural Gas Available .Yes 20 Addition Slab Area (FTZ) NA Glazing Percentage (%) 25.8% . B—, COMPLIANCE RESULTS v 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater, under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below �MENERGY USE_SUMMARY 04 05. 06 07 08 . Energy Use (kTDV/ff) Standa&T Proposed Compliance De gn Design Margin Percent Improvement Space Heating J4 77 5.98 -1.21 -25.4% Space Cooling. "175.19 175.45 -0.26 -0.1% IAQ Ventilation 2.00 2.00" 0.00 0.0% Water Heating 22.07 18.80 3.27 14.8% Photovoltaic Offset — 0.00 0.00AW -- Compliance Energy Total' 204.03 " 202.23 1.80 0.9% !!aa� ♦ sd - Registration Number:® Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-10-08 11:58:13 CERTI f E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD CF RF -0.1 Project ame: Boggs Casita Ca culation Date/Time: 11:56, Wed, Oct 08, 2014 Page 2 of 7 Calculation Description: Title 24 Analysis Input File Name: Boggs Casita-Pitchford-14.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation PROJECT HERS FEATURES The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below, reclure field verification by a certified HERS Rater. • IAQ mechanical ventilation ENERGY DESIGN RATING A This is the sum of the annual TDV energy consumption for energy use components included in the performan% compliance approach for the Standard Design Building (Energy Budget) and the annual ,TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domesticao 'Pliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use t Energy Design -Rating Margin Percent Improvement Total Energy (kTDVlf2)' 275.88 Y74.08.. 1.80 0.7% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING- FEATURES INFORMATION 01 02 03 ��� 04 05 0.6 07 Number of Dwelling Zone Floor Area Avg. Ceiling Number of Ventilation Number of Water Project Name Conditioned Floor Area (sft) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems Boggs Casita 861' 1� 3 1. 1 1 ZONE INFORMATION 01 02 " 0.3 04 05 06 07 ®' Zone Floor Area Avg. Ceiling Zone Name Zone Type HVAC System Name (ft2) Height Water Heating System 1 Water Heating.System 2 Casita Conditioned HVAC 1 casital '861 14 DHW Sys 1 'o .®0 Registration Number: pp�Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-10-08 11:58:13 CERTIE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Boggs Casita Calculation Date/Time: 11:56, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Boggs Casita-Pitchford-14.xml CORF-01 Page 3 of 7 OPAQUE SURFACES 01 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ftZ) Window Area (ftZ) Tilt(deg) 15d Wall Casita R-21 Wall (W.21.2x6.16) 15 Back 600 52 90 105d Wall Casita R-21 Wall (W21.2x6.16) 105 Right 760 57.8 90 195d Wall Casita R-21 Wall (W21.2x6.16) .195 Front 600 72 90 285d Wall Casita R-21 Wall (W.21.2x6.16) 285 Left 760 40.2 90 Roof Casita R-38 Roof Attic' 1 24.0 861 0.30 NEW 7 ATTIC A9 01 02 03 99,'04 05 06 07 Name Construction Roof Rise Ro��of'Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 3 0.1 0.85 No No WINDOWS 01 02 03 ®� 04 OS 06 07 08 09 10 Name Type Width(ft Height Surface (Orientation-AzimutVo ) (ft) . Multiplier Area (ft) U -factor SHGC Exterior Shading, NEW Window 15d'Wall (Back -15) -- -- 1 36.0 0.51 0.30 NEW 2 Window 15d Wall (Back -1 5) - -- 1 16.0 0.51 0.30 NEW 3 Window 105d Wall (Right -1T(%5 -- - 1 24.0 0.51 0:30 NEW 4 Window 105d Wall (Ri(hhQ105) -- -- 1 4.9 0.51 0.30 NEW 5 Window 105d Wall (Ri5ht-105) -- -- 1 4.9 0.51 0.30 NEW 6 Window 105d WallfvRight-105) - -- 1 24.0 0.51 0.30 NEW 7 Window 195dV1"IY(Front-195) -- -- 1 24.0 0.51 0.30 NEW 8 Window 1955,d Wall (Front -195) -- - 1 24.0 0.51 0.30 NEW 9 Window 1`956 Wall (Front -195) -- -- 1 24.0 0.51 0.30 NEW 10 Window �(&285d Wall (Left -285) -- -- 1 20.1 0.51 0.30 NEW 11 Window /�.` 285d Wall (Left -285) -- -- 1 20.1 0.51 0.30 s Registration Number: CA Building Energy Efficiency Stan d�ards - 2013 Residential Compliance Registration, Date/Time: Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-10-08 11:58:13 4 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Boggs Casita Calculation. Date/Time: 11:56, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Boggs Casita-Pitchford-14.xml CF•RF-01 Page 4 of 7 - OPAQUE OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R -value Assembly Layers Tank Volume • (gal) - Energy Factor or Efficiency Input Rating 2x4 Top Chord of Standby Loss (Fraction) Cavity/Frame: no insult /2x4 Top Chrd. Natural, as Small Storage 50 Roof Truss @ 24 in. 40000-Btu/hr Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-9.1 / 2x4 R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board.. • Cavity/Frame: R -21,12x6 R-21 Wall (W21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 Exterior Finish: Wood Siding/sheathing/decking Ab - SLAB FLOORS 01 _ 02 03®` 04 05 06 07 Name Zone Area (ft2) �Perimeter (ft) Edge Insul. R -value& Depth Carpeted. Fraction Heated w Covered Slab Casita 861 1t 86 None 0.8 No BUILDING ENVELOPE -HERS VERIFICATION 01 02 Jow 03 04 Quality Insulation Installation (QII) Quality Installation of S�prray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not^Rvquired - Not Required -- WATER HEATING SYSTEMS w®� 01 02 03 04. Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Pipe Insulation,.All Lines 1 0.0% WATER HEATERS 01 02 0.3 04 05 06 07 08 Name Heater Element�Type Tank Type Tank Volume • (gal) - Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural, as Small Storage 50 0.66 40000-Btu/hr 0 0 o®� Registration Number: CA Building Energy Efficiency Stand rds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-10-08 11:58:13 CERTIE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Boggs Casita Calculation; Date/Time: 11:56, Wed, Oct 08, 2014 Calculation. Description: Title 24'Analysis Input File Name: Boggs Casita-Pitchford-14.xml CF•RF-01 Page 5 of 7 WATER HEATING,- HERS VERIFICATION 01 - - 02 03 - - . 04 05_ 06 _ c 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use. Recirculation with Manual'Control Recirculation with Sensor Control DHW_Sys. 17hers-dhw n/a n/a nM n/a SplitAirCond - Split air conditioning `system n/a . ;HVAC SYSTEMS 01 - - = — - 02 _ , .� - -- 03 04 05 06 07 - Heating -System Cooling System HERS Verification Name System Type EER SEER Zonally Controlled Compressor t Distribution SplitAirCond - Split air conditioning `system Floor Area, Name System Type ° Name Ductee . Name Ducted System Fan System Served .. HVAC 1,casital Other Heating and Cooling System Heating Component 1• �3,� Yes Cooling Component, Yes Air Distribution. System.l- HVAC Fan 1 I 86Y J . °�� . HVAC - HEATING SYSTEMS. 01 . 02 03 40, Named Type Efficiency. „ Heating Component 1 - CnttrlF rnace - Fuel -fired central furriace 80 AFUE ' HVAC - COOLING SYSTEMS 01 02 4113. 04 05 06 07 Efficiency � " Multi -speed HERS Verification Name System Type EER SEER Zonally Controlled Compressor Charge Cooling Component 1 SplitAirCond - Split air conditioning `system 13.7 17:7 ' No No Cooling Component, : � _ 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 W 03 04 05 06 Verified Refrigerant Name VerifiedAirflowAirflow Target Verified EER Verified SEER Charge Cooling Component 1 -hers -cool Raquired 350 Required Required Required . 4J Registration Number,: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Stand` aar.'ds.- 2013 Residential Compliance Report Version - CF1R-09042014-650 Report Generated at: 2014-10-08 11:58:13 CERTIOF COMPLIANCE - RESIDENTIAL PERFORMANCE. COMPLIANCE OD Project Name: Boggs Casita Ca culation Date/Time: 1.1:56, Wed, Oct 08, 2014 Calculation Description: Title 24 Analysis Input File Name: Boggs Casita-Pitchford-14.xmi CF*RF-01 Page 6 of 7 HVAC- DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Name Type Duct Leakage Insulation R -value Supply Duct Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in attic Sealed and tested 8 Attic Attic None Air Distribution System 1 -hers -dist HVAC DISTRIBUTION :HERS VERIFICATION 01 02- 03 04 05 06 Name Duct Leakage Verification Duct Leakage. Target (.1.4* Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist Required 6.0 Icy"• Not Required Not Required Not Required owl HVAC -FAN SYSTEMS 01 02' 03 04 Name Type �► Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC FurnQe,Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 �, 02 03 Name Verified FanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 IAQ (Indoor Air Quality). FANS 01 02 .�� 03' 04 05 06 Name IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 38.61 �' 0.25 Default 0 Required W70, COOLING VENTILATION W 01 ���. 02 03 04 05 Name ®� Cooling Vent CFM Cooling Vent.Watts/CFM Number of Fans HERS Verification WH-Fan1 61 0.52459 1 Required Ca Registration Number: 0,5� CA Building Energy Efficiency StanEl Ods - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-10-0811:58:13 CERTIFE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I< OD Project Name: Boggs Casita Calculation Date/Time: 11:56, Wed, Oct 08,.2014 Calculation Description: Title 24 Analysis Input File Name: Boggs Casita-Pitchford-14.xm1 CF.*F-01 Page 7 of 7 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author. Name: Documentation Author Signature: Jon d..Scott Jon Scott Company: Signature Date: Scott Design and,Title 24, Inc, 10/8/2014 Address: CEA/HERS.Certification Identification (If applicable): . 77-085 Michigan Drive City/State ip:. Palm, Desert, CA 92211 Phone: 3 (76,0) 200-4780 X RESPONSIBLE PERSON'S DECLARATION. STATEMENT 0 I certify the following under penalty of perjury, under the laws of the State of California: e�� 1. Lam eligible under Division 3 of the Business and Professions Code to accept responsibility. fo�th* building, design identified on this Certificate of Compliance. 6 2. 1 certify that the energy features and performance specifications identified on this CertificateoCompliance conform to the requirements of, Title 24, Part 1 and Part of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Comp it ance are consistent with the info; w ro ed on other applicable compliance documents, . worksheets, calculations, plans and specifications submitted to the enforcement agency�o� approval with this b p ca .Responsible Designer Name: Responsibl si ner Si at Robert A. Pitchford Company: Da igheid: Robert A. Pitchford Design and Drafting Address: License: 77-622 Country Club STE O City/State/Zip: Phone: Palm. Desert, CA 9221.1 ,��. (760) 346-2856 - .� Registration. Number: Registration Date/Time: CA Building Energy Efficiency Stan�da ds - 2013 Residential Compliance Report Version - CF1R-09042014-650 HERS Provider: Report Generated at: 2014-10-08 11:58:13 • • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Boggs Residence Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 10/8/2014 Project Address 55-585 Southern Hills La Quirita California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 861. Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R38 861 New Wall Wood Framed R 21 2,498 New Slab Unheated Slab -on -Grade no insulation 861 Perim = 86' New Demising Wood Framed R 13 661 New FENESTRATION I Total Area: 2221 Glazing Percentage: 25.8%1New/Altered Average U -Factor: 0.51 Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status Rear (N) 52.0 0.510 0.30 none none Bug Screen New Right (E) 57.8' 0.510 0.30 none none Bug Screen New Front (S) 72.0 0.510 0.30 none none Bug Screen New Left (W) 40.2 0.510 0.30 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Fumace 80% AFUE Split Air Conditioner 17.7 SEER Setback New HVAC DISTRIBUTION Location, Heating Duct Cooling.Duct Location R -Value Status HVAC 1 casita Ducted Ducted. Attic 8.0 New WATER HEATING .Qty. Type Gallons Min._Eff Distributiori Status 1 Small Storage Gas 50 0.66 All Pipes Ins New EnergyProu by EnerqySoft User Number. 6712 RunCode: 201410-08T1,1:58:11 /D: Pae 10 of 18 r MANDATORY_ MEASURES SUMMARY: Residential (Page 1 of 3), MF_ -1 R Project Name Date Boggs Residence Casiia 10/8/2014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated _ into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are.shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans.. Building Envelope Measures: 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111(a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50.0 a : Minimum R-30 R-19 for Additions/Alterations insulation in wood -frame ceiling or a uivalent U -factor. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150.0(c): Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor. *§150.0(d): Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor. 150.0 : Air retarding wrap is tested, labeled, and installed. according to ASTM E1677-95(2000) when specified on the CF -1 R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical dama a and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: ` 1. Fenestration, including skylight products, must have a maximum U -factor of 0.58. 2. The weighted average U-factor.of all fenestration, including skylight products, shall not exceed 0..58. EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is greater, is.exem t from the maximum U -factor requirement. 150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 a 1A: Masonry or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2:.Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. . Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. ' §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of 110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 1 50.0 h : Heating and/or cooling loads are calculated in accordance with ASH RAE •SMACNA or ACCA. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 110.2(c). §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wra ped with insulation having an installed thermal resistance of R-12 or greater. §150.0(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 110,16 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Boggs Residence Casita 1101812014 . §150.00)2A: All domestic hbt water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE 120.3-A. . i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. s iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. . 150.0(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used " §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross =sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.O(m)7: Exhaust fans stems have"back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause de radation of the material. 150.0(m)10: Flexible ducts cannot have porous inner cores. §150.0(n)1: .Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include all the following components : ',` A. A 120V electrical receptacle that.is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line with a ca aci of at least 200,000 Btu/hr. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures:. . §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional. inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150.0 : Residential pool systems or, equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of. 150.0 Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance ' with TABLE 150.0-A or TABLE 150.0-B as applicable. 150:0 k 1 C: The wattage of permanently installed luminaires shall be determined ass ecified b 130.0(c). 150.0 k 1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency. <= 20 kHz. §150.0(k)1E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated.to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.3 by EnergySoft User Number: 6712 ID: Page 12 of 18 4 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Boggs Residence Casita 10/8/2014 150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 150.0(k). 150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft' or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with. a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2 130.4, 140.7, and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)l 1: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130. 1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and a ress. EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 13 of 18 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Boggs Residence Casita Date' 10/8/2014 System Name. HVAC 1 _casita ° Floor Area 861 ENGINEERING CHECKS SYSTEM LOAD 'Number of Systems . 1 COIL CFM - Total Room Loads 1,250 Return Vented Lighting Return Air Ducts Return Fan Ventilation 201 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating S stem Sensible Latent CFM i Sensible Output per System 89,000 17,429 1,691 305 19,672 Total Output Btuh 89,000 0 Output Btuh/s ft 103.4 1,006 967 Cooling System 0 0 Output per System 37,200 8,811 3,479 201 91673 Total Output Btuh 37,200 0 1,006 28,252 5,170 0 Total Output Tons 3.1 967 Total Output Btuh/s ft 43.2 Total Output s ft/Ton 277.7 31,279 Air System . CFM perSystem 1200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24ANB736-58CVX090 27,550 5,134 89,000 Airflow cfm/s ft 1.39 r Airflow cfm/Ton 387.1 Outside Air % 16.7 % Total Adjusted System Output 27,550 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 5,134 Aug 3 PM 89,000 Outside Air cfm/s ft 0,23 Jan 1 AM Note: values above given at ARI conditions. HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 201 cfm 71 OF 640F 133 OF 1330F Heating Coil Supply Fan 1,200 cfm 133 OF ROOM;; 720F COOLING SYSTEM PSYCH ROM ETICS. Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 201 cfmCooling 71 /61 °F y 78/64°F 56/55°F 56/55°F c Coil. Supply Fan 57 / 55 OF 1,200 cfm -- - 59.1 % I ROOM: t 70/61 OF y Energ Pro 6.3 by Energ Soft User Number: 6712 RunCode: 201410-08711:58:11 /D:. Page 14 of 18 ROOM LOAD SUMMARY Project Name Boggs Residence Casifa Date 10161201:4, System Name HVAC I casita.. Floor Area 861_ ROOM LOAD SUMMARY_ , ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name ..Mutt. CFM Sensible Latent . CFM Sensible Latent CFM Casita Casita 1 1,250 17,429 1,691 1,250 17,429 1,691 . _Sensible 305— fF r t } i Total includes ventilation load for zonal systems. PAGE-TOTAL TOTAL F 1,250 1,250 1 17,429 17,429 11691.1. 1,691 305 19,672 305 19,672 'EhergyPrp 6.3 by Energ YSoft User Number 6712. Run Code: 201410-08711:58:11.. _ ID: Pae 15 of 18 • i ;ROOM HEATING PEAK. LOADS Project Name Boggs Residence Casita Date 10/8/2014. ROOM -INFORMATION DESIGN -CONDITIONS Room Name Casita Floor Area . 861.0 ftz. Indoor,Dr Bulb_.Tem erature 72 OF, time of Peak Jan 1 AM Outdoor'Dry Bulb. Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X, Xf X X X X. X X X X X. X X X X X X X, X X X. X X X X X X AT OF = c _ = _ = - - _ - _ _ _ _ _ = - - _ _ _ = - - _ - - = = = 46 Btu/hr R-38 Roof Attic 861.0 0.0260 46 1,030 R-21 Wall (W,21.2x6.16) 2,498.0 0.0690 46. 7,929 Low -E Vinyl 222.0 6.5100 46 5,208 Slab -On -Grade periin = 86.0 .0.7300 46 2,888 it • Items shown with an asterisk (`) denote conduction Infiltration:[ t.00 X. ' 1.064 'Schedule Air Sensible Fraction through an interior surface X 861 X Area another room 14.00 X 0:266 Height ACH Page Total ./ 60 ]' X AT 17,054 = 2,618 TOTAL HOURLY; HEAT, LOSS FOR ROOM. 19,672 EnergyPro 6.3 by EnergySoft User Number. 6712 RunCode: 2014-10-08711:58:11 ID: , Page 16 of 18 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Boggs Residence Casifa 10/8/2014 ROOM- INFORMATION DESIGN CONDITIONS Room.Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 861.0 ft2 Outdoor Wet'Bulb Temperature 78 OF Indoor Dry Bulb.Temperature 70 OF. Outdoor Dailv Ranae: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Bt'/h R-38 Roof Attic R-21. Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W 21.2x6.16) u r 861.0 X 0.0260 X 56.0 1,254 548.0 X X X X X X X X 0.0690 X X X X X X X X 25.0 = _ = = - = = = 24.5 702.2 0.0690 32.3 24.5 528.0 0.0890 27.7 0.0 719.8 0.0690 32.1 0.0 21.3 4.9 38.2 0.0 21.3 24.0 38.2 0.0 0.0 21:3 24.0 23.7 21.3 24.0 23.7 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area . GLF. Area GLF NEW NEW NEW NEW NEW NEW NEW NEW NEW (N) (N) (E). . (E) (E) (E) (S) (S) (S) 0.0 0.0 0.0 X X X X X X X X X 21.3 + + + + + + + + + 36.0 X X X X X X X X X 24.5 = =` = = = = 21.3 16.0 24.5 21.3 24.0 38.2 0.0 21.3 4.9 38.2 0.0 21.3 4.9 38.2 0.0 21.3 24.0 38.2 0.0 0.0 21:3 24.0 23.7 21.3 24.0 23.7 0.0 21.3 24.0 23.7 Internal Gain. Occupants 2.6 OccupantsX 245 Btuh/occ. Equipment, 861 Floor Area X 0.50 w/sqft Infiltration: 1.064 X 0.94 X 55.24 X 42 = Air Sensible CFM ELA AT TOTAL HOURLY.SENSIBLE HEAT GAIN FOR ROOM Latent Gain , Occupants 2 6. Occupants X 155 Btuh/occ. Infiltration: 4;771 X 0.94 X 55.24 X 0.00523 _ Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM EnergyPro 6.3 by Ener4ySoft User Number: 6712 RunCode: 2014-10-08T11:58:11 /D: Page Total 1,567 1,008 1.593 6,3671 unr 884 393 916 187 187 916 568 568 568 5,18 Ih r = 1,469 2,309 17,429 Btu/hr = 400 1,290 400 Pae 17 of 18 L] r RESIDENTIAL ROOM.COOLIN.G LOAD SUMMARY , Project Name Date Boggs Residence Casifa 10/8/2014. _ ROOM INFORMATION DESIGN_ CONDITIONS Room Name Casita Outdoor Dry Bulb. Temperature 112 OF Floor Area 861.0 ff2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry- Bulb. Tem erature. 70. OF Outdoor Daily Range: 34 OF O a ue Surfaces Orientation_ _ Area LI -Factor CLTD' Btu/hr , X. X = X X _ X X _ X X = X X _ X X _ X X = X X _ X X = " Page Total. 0 Items shown with an asterisk (") denote conduction. through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) d` Shaded Unshaded Fenestration Orientation, Area GLF, Area •GLF Btulhr NEW (W) 0.0 X 21.3 + 20.1 X 36.4 = 732 NEW (W) 0.0 X 21.3 +' 20.1 X 36.4 = 732 X +. X .. X + X = X + X _ X + X _ X + X _ X + X X + X - Page: Total 1,464 Internal Gain " h Btulhr . Occupants 2.6 Occupants X 245 Btuh/occ. 633 Equipment 861 Floor Area X 0.5b w/sgft = 1,469 Infiltration: 1.064 X 0.94 X 55.24 X. 42 = 2,309 Air Sensible CFMELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM - 17,429 Latent Gain.. Btu/hr Occupants 2.6 , . Occupants X 155 Btuh/occ. = 400 Infiltration: 4.771 X 0.94 X 55:24 X 0.00523 = 1,290 Air Sensible CFM ELA. AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 400 Ene Pro 6:3 by Energ ySoft User Number: 6712.. RuriCode: 201410-08T11:58:11 JD: „Pae 18 of 18