Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
0005-272 (AR)
- -. �. � fit, � .•, - _ T "LICENSED CONTRACTOR DECLARATION I -hereby affirm under penalty of perjury that'I am licensed under provisions`of Fes- 7 Chapter 9 (commencing with Section 7000) of Division 3 of the Business and W. Professionals Code, and my'License is in full force'and effect. ., O �-Co. _ License # , Lic. Class Exp. Date t`�d•�- ,r• v. r� W ; " ' 343: 55 Pi C36 C8 MC 0212c'Il2C. o Z ate i C " c'�' Signature of Contractor `"� ---✓� r`- H OWNER -BUILDER DECLARATION . W W I hereby affirm under penalty of perjury that I am exempt from the Contractor's ~ _a fn License Law for the following reason: Z_ ( ) I, as owner of the property, or my employees with wages as their sole Co' mpensation, will do the work,• and the structure is not intended or'offeeed for sale (Sec. 7044, Business &Professionals Code). as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code)`. co O I am exempt under Section B&P.C. for this reason LO N Date Signature of Owner 0, rn Q WORKER'S COMPENSATION DECLARATION Z I hereby affirm under penalty of perjury one of the following declarations: Lo < O O I. have and will maintain a certificate of -consent to self -insure for workers' X u! U- compensation, as provided for by Section 3700 of the Labor Code, for .the O J Q performance of the work for which this permit is issued. m Q' C) ( ) I have and will maintain workers' compensation insurance, as required by O U Q Section .3700 of the Labor Code, for the performance of the work for which this L- rn H permit is issued. My workers' compensation insurance carrier &policy no. are: 19t.Z Carrier Policy No. ri, --I STATE PUND 229.00 0014757 (This section need not be completed if the permit valuation is for $100.00 or less). () I certify that in.the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become Fs . bject to the workers' compensation provisions of Section 3700 of the Labor ode, I shall forthwith comply with those provisions. Date: f " Applicant -r -/ Warning: Failure to secure Workers' Cofnpensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application: 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the. City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within .180 days from date of issuance of such permit,, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. /t7�,. gnature (Owner/Agent) �'Date" e• PERMIT # ` z i' -' BUILDING PERMIT DATE VALUATION -' LOT ��"�� ' TRACT JOB SITE . ADDRESS gOiT1 H . AST M, as APN - I✓� Y11110 OWNER - •`—_gi�pp__ryry��yyyyy—yy��i��.���}}��_ CONTRACTOR/DESIGNER/ENGINEER �r,�_9• �=yy---, • r i�Ji*e„. D AJU) �.3' V.1.Jd1/.1, V iV bY�..'RY - ••��,��yy:-: /y_�_�,���+(_�ryy p� M L CONE $.SZl. CT101 ' 55-59911110,MHL RE N IMALO 54310 AVE DA JUAN, LA QtTZAI'rA � A RUB' •, ., , - QMITA CA 42253 (760)W4447 iIDU USE OF PERMIT lE` MEN- 1 AL ALyM014 ` ATTACk1M 1SWROOM 2 BATH CAS1TA ADDITION. 614 SY. CUSTOM CONSTRUCTION 614.09 3F PLAN CHECK ME 7 ill w000�435'<31 � $2�0.9� CONSTRUCTION FEE 101-000-418-000 $401.-% W&CHANict,L nz 101-000-42:1-000 $20.50 ELECTRICAL.FEE J 101-400-4.30-000 $52.50 PS1UAR.010 FRE 101.000-419.000 $43,00 r 'S a t t09101B-TOT.P,LO09MUMCiN"DPLM ckSts., c V86.48 LESS PRE. -PAM1 F'E6�14 $0.00 RECEIPT DATE B/% DATE•FINALED INSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALSMECHANICAL aAPPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade A Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing l3 Compressor Insulation ./ _per Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath —dZ my Final Final BLOCKWALL APPROVA, S POOLS - SPAS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: Bin f City pf.La QuInta' Building 9 SAW Division P.O. Box I SO4 7B.49S Calle Tampico Tennft # La Quinta, CA 922S3 6COS Building Permit Application' and Tracking Sheet ...... .... . ... . ..................... owner's Name; M UD Project Address:. Address:' A. P. Number: 7, 7- 93 City'ST. Zip: ........ . ..... Legal Description:, ............... ...... — .. . . . . . . . . . . . ....... . Telephone: Contractor: v Project Description: Address: Cit%..ST. Zip: ..... . . . . FSZ,T�T (54-64 . .. ............... Telephone: . . ........... ..... ... Lic.;- '. , III 0! State 40 City Lic. �esigner- Arch.. Engr.! -A Address: Y City. T Zi Type: Occupancy.,ConstrucuOn Project type (circle one): New Aidd'n Alter Repair DeuiO tate Li •Sq. FL/)( 16 ? # ories: Units: Name of Contact Person: —St Value of Project: Telephoned of Contact.person: .Estimated .K*, ",& P . ..... .... . M . . ... . ....... ............ ............ # M T. Ot . . ......... ........... a... ............ . ...... .... ........ . .Y struitu . kg , .. ............... ...... ................. ....% .. Eru3sca . ... .M . ..... . M ked...... Title-24*0dq ..... . .... .. .......... PT. .. .•...... ..... left: .... .. ....... RWRRM t ............... ...... .... . ... . ..................... ............... ...... — .. . . . . . . . . . . . ..... . . . . . ............... . . . . . . . . . . . . . . . . . . . . . ........... -A Yr Desert Sands Unified School. District .47-950 Dune Palms Road wr Notice: _ �� . La Quinta,CA 92253 .} : �, , h. r C LA' Document Cannot Be Duplicated • 760-771-8515 - - - l' CERTIFICATE OF COMPLIANCE `� Date 6/20/00 , ` }.. . ',; ,' a' APN # 769-820-016 ''- r ,.. ; ` , No. 20567 r, , `` '; ti `r ', Jurisdiction La Quints 4 Owner Name GWid unson y i "' Permit # 0005-272- , rs ' No. 55-599f streot Southern Hills. - t - 3 Log # City-! Li Quints` • ' Zip 922534 ' �` - -Study Area 'Tract # { , Lot #}Square Footage 614 Type of Development Residential Addition `' . = ' ;{"\� j9. .. No.'of Units 1 + „ , Comments ' M • r i µ - At the present "time, the Desert Sands• Unified* School, District does not collect fees: on garages/carports,., covered - patios/walkways,'residential additions under- 500. square feet, detached accessory structures or replacement mobilehomes. It has been determined_ the above-named owner is exempt from paying'school fees at this time due to t} ifollowing reason: ,� ,� `'EXENII'TIUIV. NOS' APPLICABLE: This certifies that school facility fees ilinposed pursuant to, _ Government Code 53080, - in the'amount of 2.05 X 614* ' , or $ 1,258.70 the property listed above and that building ". + permits and/or Certificates of Occupancy for this`square footage in this proposed project may now be issued ,Pees Paid By CC/Downe Savin s/Niarvn `Jordan `s Telephehe`-, 7601 5644447 `5�6:4` 4447 Name on the check; + By .. Dr. Doris son 1 • : , :a r' Wil - - Superintendent Fee collected /exempted by Mary Ann L.' Borja Payment Received' $1,58 70 - ," •, ` ' +" Check No. 03610061262'��' sw Signature s ' NOTICE: Pursuant of Assembly Bi113061 (CHAP 549, $TATS.,199e) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is assued or on which they are paid to the Distrlct(s) or to another public entity authorized to collect them on the District('s)(s') behalf, whichever is earlier. ' -• - - - - - Collector: Attach a copy of county or city plan check application`form to district copy for all waivers. ti Embossed Original- Buildin •WpUApplicantl CoPY A,PPlic.an.t/Recei t Copy ,Accounting '+ � : , "Y May 17 00 03 :1 P p Nl 'ncy- cu(J!muhldscr•; " 4-02151.4 1 3. 2600 p •;1 *' Ak FGA WEST I1 RESIDENTIAL AS .1 P.O.fBOX. 128121,1,'A QUINTA,'CA 92253•. (760) 776-5100 FAX (760) 776-5111 April 14, 2000 W. & Mrs, Darreld I Gudmundson 55-599 Southern Hills . '+ La Qulnta, CA 92251-1" Reference: Architectural Change Request fora Room Addition •Dear Mr: & Mrs. Gudmundson: The Planned Unit Development Architectural Committee and the -Landscape Committee have reviewed your p!ans for a'.room addition at their meetings'on April -11th and.April 12`" respectively' and approved your,application''as submitted with the fallowing comments -'After the existing trees are. moved and if;they do not live; the trees; will be replaced at your expense. On all other - homes, Vie bender board is being replaced with .a brownish 7rex-like material and it is suggested that you use this same,type of material. Review by the.Comrnittee is only for general conformance with the'architectural guidelines. It is ` the responsibility of. the ownertc Fully: understand and conform to the architectural guidelines ,.criteria whether;or not all dcriciencies'are noted during review, It is also the owner's full responsibility, to field Verify all existing..conditions. 'The Committee's decision"Mth regard to project design will be final. Please refer to the PUO Architectural guideline s�and Appllcatlon for r ,^ , `•. Change for. all required' submittals. Please contact, Raphael Villareal, supervisor for valley Gardening Service at 760/399-1844 and. I Carol Fuller, the Association Manager, .prior to any irrigation. modifications associated with. this. . change, Upon completion of changes, please c.on .act Carol Fuller. Damage to thin landscaping, i.e., shrubs, trees,'flowers and turf is the responsibility of the contractor.` The landscaping must , be brought back toots original condition when the project is cornpleted. - . • , Approvais.given'by the"ArLhitectural Corrtmlttee are good for only six months from the date on the•approval letter. -After that time.a new appkation'must be submitted. " If you have any additional questions or concerns; please do not hesitate. to contact Carol. Fuller, Assoclation Manager, at 760/776=5100, Ext. 20. ' Sincerely, ' k ' PGA WEST II RESIDENTIAL ASSOCIATION For, the PUD Architectural Committee f Carol Fuller Association' Manager- ' cc: - Board of Directors " Unit File K �� TITLE 24 REPORT Jr Title 24 Report for: Gudmundson Residence (Guest House Addition) 55-599 Southern Hills La Qu i nta, CA 92253 Project Designer: , Robert A. Pitchford .41-625 'Eclectic Ste. A-2 a `Palm Desert, CA 92260 (760) 346-2856 a Report Prepared By: Tim Scott BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 t �F LA QU- Job Number: GITYING & SAF�T�' . 901.51 BUILD P����� �. AP ` FOR C.O�'STRUCT' ` Date: A'�-=. DATE_ 5/19/00 1.. r., The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 2.1 By EnergySoft Job Number: 901.51 User Number: 3665 ' TABLE'OF CONTENTS `. Cover Page 1 ` Table of Contents 2 Form CF' -1 R Certificate of Compliance 3 'Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method'Summary 7 Form CF -6R Installation Certificate 11 HVAC System Heating and Cooling Loads Summary 18 Room.Load Summary, 19 Room Heating Peak Loads „ 20 Room Cooling•Peak Loads 21 f HVAC Equipment Specifications22 y , • I i EnergyPro 2.1 By EnergySoft Job Number: 901.51 User Number: 3665 1 • 0 • • Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Gudmundson Residence (Guest House Addition) 5/19/00 roiec i e Date 55-599 Southern Hills - La Quinta vroject Aaaress BREEZE AIR CONDITIONING (760) 346-0855 Documentation Author i a ep one Computer Performance 15 Building ermi an Check I D-aTe- -Fi-el-dCffe—Cka e Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: .614f? Total Conditioned Slab Area: 614f? Building Type: Frame Type (check one or more) Location/Comments (attic, garage, typical, etc.) ® Single Family Detached (SFD) ❑ Addition Alone ❑ Single Family Attached (SFA) ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 340 deg Floor Construction Type: ❑X Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor BUILDING SHELL INSULATION Component Type Frame Type Const. Assembly. U -Value Location/Comments (attic, garage, typical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Shadinci Devices Type Orientation Area Labeled'Fenestration Interior Exterior Overhang Side Fins (SF) U -Value SHGC (roller blind, etc.) (shadescreen, etc.) Yes / No Yes / No Front (North) 48.0 0.85 0.88 Drapery Bug Screen ❑ X❑ ❑ X❑ Front (North) 16.0 0.87 0.88 Drapery Bug Screen ❑ X❑ ❑ X❑ Left (East) 16.5 0.87 0.88 Drapery Bug Screen ❑ x❑ ❑ X❑ Left (East) 6.3 0.72 0.88 Drapery Bug Screen ❑ X❑ ❑ X❑ Rear (South) 32.0 0.87. 0.88 Drapery Bug Screen X❑ ❑ ❑ x❑ Right (West) 20.5 0.87 0.88 Drapery Bug Screen ❑ a ❑ o ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ El 1:1 ❑ ❑ ❑ T❑ ❑ ❑ ❑ ❑ El El 1-1 El Run Initiation Time: 05/19/00 16:23:20 Run Code: 958778600 EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.51 Page:3 of 29 • -OMPLIA CE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Tim Scott Title/Firm: Robert A. Pitchford Title/Firm: BREEZE AIR CONDITIONING Address: 41-625 Eclectic Ste. A-2 Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephon : (760) 346- 855 (signature) (daft) Title/Firm: Address: Telephone: (signature/stamp) date Run Initiation Time: 05/19/00 16:23:20 Run Code: 958778600 EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.51 PageA of 29 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Gudmundson Residence (Guest House Addition) 5/19/00 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Split Heat Pump 8.0 HSPF Ducts in Attic 4.2 Setback HVAC -1 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Heat Pump 12.7 SEER Ducts in Attic 4.2 Setback HVAC -1 WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value Standard Gas 50 gal or Less Small Gas Recirc/Time+Temp 1 40,000 50 0.53 n/a 12 • 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS • -OMPLIA CE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Tim Scott Title/Firm: Robert A. Pitchford Title/Firm: BREEZE AIR CONDITIONING Address: 41-625 Eclectic Ste. A-2 Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephon : (760) 346- 855 (signature) (daft) Title/Firm: Address: Telephone: (signature/stamp) date Run Initiation Time: 05/19/00 16:23:20 Run Code: 958778600 EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.51 PageA of 29 • Certificate,of Compliance:.Residential (Addendum)' CF -1 R Gudmundson'Residence (Guest House Addition) 5/19/00 • Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies t Dasea on the adequacy of the special justification and documentation submitted. The DHW System "Standard Gas 50 gel or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Bla The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. a e A HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the suofpervision of a CEC approved HERS provider. The HERS rater must document the.field,verification and diagnostic testing these measures on a form CF -6R. an Field 1 1 , v t 1 l F%UII IIIIIIOLIVII IMM. W01I7/VV IV.GJ.GV• Nut] %Ouu6'. `J;)o//oouu EnergyPro 2.1 - By EnergySoft User Number: 3665 Job Number: 901.51 Page:5 of 29 • 1 . i" F%UII IIIIIIOLIVII IMM. W01I7/VV IV.GJ.GV• Nut] %Ouu6'. `J;)o//oouu EnergyPro 2.1 - By EnergySoft User Number: 3665 Job Number: 901.51 Page:5 of 29 • 1 . Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may ,be superseded by more stringent compliance requirements listed on the Certificate of • Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component specifications.. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMEN Building Envelope Measures ® "§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -value. "§ 150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value (does not apply to exterior mass walls). `§ 150(d): Minimum R-13 raised Floor insulation in wood framed floors. § 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 perm/inch. ® §118: Insulation specified or installed meets quality standards. Indicate type and form. ®§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. , 2: Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ® §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA.- ® §150(i): Setback thermostat on all applicable heating and/or cooling systems. ® §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.56 energy factor shall be externally wrapped with R-12. 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation, piping between heat source and tank insulated. 3.Insulation on the first 5' of pipes closest to water heater tank, non -recirculating systems (R-4 or greater), buried or exposed piping in recirculating sections of hot water systems, cooling system piping below 55 deg F. ®"§150(m): Ducts and Fans 1. All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICBO 1997 UMC sections 601 603; ducts insulated to a minimum installed R-4.2 or ducts enclosed entirely within conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct closure system that meets the applicable requirements of UL181, UL181 S, or UL181 B and other applicable specified test for longevity given in 150(m). 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems servng conditioned space have either automatic or readily accessible, manually operated dampers. §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no pilot or electric resistance heating. 2. System is installed with at least 36" of pipe between filter and heater, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. U §115: Central Furnaces, pool heaters, spa heaters or household cooking appliances have no constant pilot light. Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ® 150(k)2: Rooms with a shower or bathtub must either have at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in 150(k)2.; and recessed ceiling are IC (insulation cover) approved. EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.51 Page:6 of 29 Computer Method Summary (Part 1 of 3) C -2R Gudmundson Residence (Guest House Addition) 5/19/00 ��rojectTe pate 55-599 Southern Hills La Quinta Building Permit# Plan ec a e le ec a e BREEZE AIR CONDITIONING (760) 346-0855 Documentation Author Telephone Computer Performance 15 tomanance nnernoa (FaCK20a or Combuterl ClimaTeone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 6.45 8.57 -2.12 Space Cooling 62.51 40.19 22.32 Domestic Hot Water 31.51 30.42 1.09 Totals 047 79.19 21.28 Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: 614 Floor Construction Type:X❑ Slab Floor Single Fam Detached ❑ Raised Floor (North) 340 deg 1.00 Total Conditioned Volume: 5,986 1 Slab Floor Area: 614 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units Zone Type HVAC -1 614 5,986 1.00 Sleeping OPAQUE SURFACES Act. R-21 Wall (W.21.2x6.16) Type Area U -Val. Azm. Tilt Roof 614 0.028 340 0 Wall 316 0.059 340 . 90 Wall 203 0.059 70 90 Wall 326 0.059 160 90 Wall 206 0.059 250 90 0 Solar Gains Y/N Thermostat Vent Type Hgt. Area SleepingStat 2 n/a Form 3 Reference Location / Comments R-38 Roof (11.38.204.16) Guest House Addition R-21 Wall (W.21.2x6.16) Guest House Addition R-21 Wall (W.21.2x6.16) Guest House Addition R-21 Wall (W.21.2x6.16) Guest House Addition R-21 Wall (W.21.2x6.16) Guest House Addition Run Initiation Time: 05/19/00 16:23:20 Run Code: 958778600 EnergyPro 2.1 By EneravSoft User Number: 3665 Job Number: 901.51 Pagel of 29 Computer Method Summary (Part 2 of 3) C -2R Gudmundson Residence (Guest House Addition) 5/19/00 •P�ro/ectZi a -ate U -Value Act. Glazing Type Location/ # Type Area SHGC Azm. Tilt Comments 1 Window Front North 48.0 0.850 0.88 340 90 Double Mtl Uncoated Default Guest House Addition 2 Window Front (North) 16.0 0.870 0.88 340 90 Double Mtl Uncoated Default Guest House Addition 3 Window Left (East) 12.0 0.870 0.88 70 90 Double Mtl Uncoated Default Guest House Addition 4 Window Left (East) 6.3 0.720 0.88 70 90 Double Mtl Uncoated Default Guest House Addition 5 Window Left (East) 4.5 0.870 0.88 70 90 Double Mtl Uncoated Default Guest House Addition 6 Window Rear (South) 16.0 0.870 0.88 160 90 Double Mtl Uncoated Default Guest House Addition 7 Window Rear (South) 16.0 0.870 0.88 160 90 Double Mtl Uncoated Default Guest House Addition 8 Window Right (West) 4.5 0.870 0.88 250 90 Double Mtl Uncoated De cult Guest House Addition 9 Window Right (West) 16.0 0.870 0.88 250 90 Double Mtl Uncoated Default Guest House Addition INTERIOR AND EXTERIOR SHADING # Interior Shade Type SHGC Exterior Shade Type Window I SHGC g�Vd: Left Fin Right Fin t.e-L n. Hat.Is-D' t. Len. F 1 Drapery 0.68 Bug Screen 0:76 2 Drapery 0.68 Bug Screen 0.76 3 Drapery 0.68 Bug Screen _ _ _ _ _ 0.76 4 Drapery 0.68 Bug Screen 0.76 - - - - - - - - - - - - - 5 Drapery 0.68 Bug Screen - - - - - - - - - - - - 0.76 6--2.0-0.1 Drapery 0.68 Bug Screen 0.76 4.0 4.0 2.0_ 0.1 2.0 2.0 7- Drapery 0.68 Bug Screen _ _ 0.76 4.0 4.0 2.0 0.1 2.0 2.0 _ _ _ _ 8- Drapery 0.98 ug Screen 0:76-- - - - - - - - - - - - Y Drapery 0.68 Bug Screen 0.76 - - - - - - - Run Initiation Time: 05/19/00 16:23:20 Run Code: 958778600 EnergyPro 2.1 By Energy oft User Number: 3665 Job Number: 901.51 Page:8 of 29 t Computer Method Summary .(Part 3 of 3) C -2R Gudmundson Residence (Guest House Addition) 5/19/00 Project Title a e THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments } PERIMETER LOSSES F2 Insulation Type Length Factor R -Val.. Depth Location / Comments Slab Perimeter 27 0.76 0.0 0 Guest House Addition Slab Perimeter 98 0.76 0.0 0 Guest House Addition HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) Split Heat Pump 8.0 HSPF Ducts in Attic • Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. , Cooling Equipment Type (air conditioner, heat pump, evap. cooling) Split Heat Pump z Duct Thermostat Location / R -Value Type Comments 4.2 Setback HVAC -1 Duct Thermostat Location / R -Value Type Comments 4.2 Setback HVAC -1 WATER HEATING SYSTEMS Duct Minimum Efficiency Location (SEER) (attic, etc,) 12.7 SEER Ducts in Attic Standby R -Value System Name Type � Type Syst. (Btu/hr) (gal) Efficiency z Duct Thermostat Location / R -Value Type Comments 4.2 Setback HVAC -1 Duct Thermostat Location / R -Value Type Comments 4.2 Setback HVAC -1 WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type � Type Syst. (Btu/hr) (gal) Efficiency Loss (%) r' Ext. Standard Gas 50 gal or Less Small Gas Recirc/Time+Temp 1 40,000 50 0.53 n/a 12 1 For small gas storage (rated input <= 75000 Btu/hr); electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 05/19/0016:23:20 Run Code: 958778600 EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.51 Page:9 of 29 4 i• Com. puter Method Summary .(Addendum)' C2 -R Gudmundson Residence (Guest House Addition) 5/19/00 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies - based on the adequacy of the special justification and documentation submitted. Plan ` Field The DHW System "Standard Gas 50 gal or Less" Energy Factor ='0.530. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. w, HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS pruviuer. I lie nr-rc,? rain must uuaumenr uIe new vennaauun anu u+aynusuc resuny vl Mese measures on a rurrn %.r-om. ah Rela + u 5 Run InitiationTime: un Code: 958778600 EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.51 Page: 10 of 29 INSTALLATION CERTIFICATE (Part 1 of 7) CF -6R Site Address Permit Number An installation certificate is required to be posted at the building site or made available for all appropriate inspections. (The information provided on this form is required; however, use of this form to provide the information is optional.) After completion of final inspection; a copy must be provided to the building department (upon request) and the building owner at occupancy, per Section 10-103(b). HVAC SYSTEMS: Heating Equipment Equip. # of Efficiency, Duct Duct or Heating Heatingg Type (pkg., CEC Certified Mfr Name Identical (AFUE, etc.) Location Piping Load Canacify heat pump) & Model Number, Systems [>= CF -1 R Value] (attic, etc.) R -Value (Btu/hr) (Btu/hr) Cooling Equipment Equip. CEC Certified Compressor # of Efficiency, Duct Cooling Cooling Type (pkg., Unit Mfr Name & Identical (SEER, etc.) Location Duct or Load Capacity heat pump) Model Number Systems [>= CF -1 R Value] (attic, etc.) R -Value (Btu/hr) (Btu/hr) 1. >= reads Greater Than or Equal to. I, the undersigned, verify that equipment listed above is: (1) the actual equipment installed; (2) equivalent to or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) the equipment meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable. . Signature, Date Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner WATER HEATING SYSTEMS: CEC Certified Distribution If Recir- # of Rated2 Tank Effie 2 External Heater Mfr Name Type((Std, culation, Identical Input (kW Volume ciencv Standbyy Insulation Type & Model Number Point -of -Use) Control Type Systems or Btu/hr) Gallons (EF, RE) Loss (%) R -Value 2 For small gas storage (rated input of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list Energy Factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Recovery Efficiency, Standby Loss and Rated Input. For instantaneous gas water heaters, list Recovery Efficiency and Rated Input. 3 R-12 external insulation is mandatory for storage water heaters with an energy factor of less than 0.58. Faucets & Shower Heads: All faucets & showerheads installed are certified to the Commission, pursuant to Title 24, Part 6, Section 111. I, the undersigned, verify that equipment listed above my signature is: (1) is the actual equipment installed; (2) equivalent to or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) equipment that meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable. Signature, Date Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy EnergyPro 2.1 By Energysoft User Number: 3665 Job Number: 901.51 Page: 11 of 29 p .INSTALLATION CERTIFICATE '(Part 2 of 7) CF -6R • Siteses ress -Pe�ml umber o r FENESTRATION / GLAZING: Product U- Product Interior or Value 1 SHGC' Exteror Shading (=<CF -1 R (=< CF -1 R # of Quantity Square .Device or Comments/ Manufacturer/Brand Name value)'? value} Panes (Optional) Feet Overhang Special Features ROUP -LIKE PRODUCTS- .2, 3. 4. 5. 6. 7. 8. g, 10. 12. 13. , .14. 15. a 1. Manufactured Fenestration products use the values from the product label. Field fabricated fenestration products use the default values from Section 116 of the Energy Efficiency Standards. 2. Installed U -value must be less than or equal to values from CF -11R. Installed SHGC must be less than or equal to values from CFA R, or a shading device (interior, exterior or overhang) is installed as specified on the CF -1 R. Alternatively, installed weighted average U -values for the total fenestration area are less than or equal to values from CF -1 R. �( I, the undersigned, verify that the fenestration/glazing listed above my signature (1) is the actual fenestration product installed; (2) is equivalent to or has a lower U -value and lower SHGC than that specified in the certificate of compliance ,(Form CF71 R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) the product meets or exceeds the appropriate requirements for manufactured devices (from Part 6), where applicable. Item #sSign�Da e (if applicable) Item #s Signature, Date (if applicable) 1nstailling Subcontractor Co. ame OR General Contractor (Co. Name) OR Owner OR Window Distributor , Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner OR Window Distributor Item #s Signature, Date Installing Subcontractor (Co. Name) (if applicable) �} OR General Contractor (Co. Name) OR Owner OR Window Distributor • COPY TO: Building Department HERS Provider -(if applicable) Building Owner at Occupancy EnergyPro 2.1 By EnergySoft ' User Number: 3665 Job Number: 901.51 Page: 12 of 29 i INSTALLATION CERTIFICATE (Part3 of•7) CF -611 S7�eAddress DUCT DIAGNOSTICS -Perms um er This buiding obtained compliance credit for: ❑ Duct sealing ❑ Duct Area Reduction ❑ ACCA Manual D design and installation , CREDIT FOR REDUCED -DUCT SURFACE AREA OR LOCATION ACCA Design 3 Duct Location" Exterior Measured ' ❑ Duct Design on Plans Surface Area Exterior Surface Installed duct diameters match (COAR) Area❑ plans ❑ Attic ❑ TXV installed f ❑ Crawlspace ❑ Access to TXV valve (if installed) ❑ Basement ❑ No TXV, Fan air flow (CFM) ❑ Other Total ❑ Duct Leakage Measured ❑ Measured leakage (CFM) HVAC fan air flow (CFM) (measured or calculated as 'Ignore ducts in ❑CFM = 0.7 x Anoor for CZ 8 through 15 conditioned space. ! Only a check is ❑ CFM = 0.5 x Anoor for. CZ 1 through 7 & 16 required for location or, it the equipment size is known, the larger of 1 or 2. credit. 1. ❑ CFM = 400 x Cooling Capacity in Tons or 2. ❑ CFM = 21.7 x Heating Capacity in Thousands of Btu per hour) Leakage divided by HVAC Fan air flow (must be =< 0.06) For AEROSOL TYPE SEALANTS ONLY - The following diagnostic testing was completed: ❑ Duct Fan Pressurization at rough - in measured leakage CFM CHECK AFTER FINISHING WALL: ❑ Pressure Pan Test 0 House pressuezation test ❑ Visual Inspection of Duct Connections i Provide Follow-up Test Results or Inspection Results on a Separate Page ❑This certifies that the ducts surface area and duct locations were verified. When compliance credit is claimed for duct surface area reducitons and duct location improvements beyond those covered by default assumptions, builder employees or subcontractors shall certify that they have verified that the duct surface area and locations match those on the plans and shall, indicate the duct surface area in each duct location on the CF6R. ❑ This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] Tests Signature, Date ns flingSubcontractor Co. ame Performed OR General Contractor ( o. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy EnergyPro 2.1 By,EnergySoft User Number: 3665 Job Number: 901.51 Page: 13 of 29 M r t , -INSTALLATION CERTIFICATE (Part 4 of 7) CF -6R Sito Address -Permit Number 4 BUILDING ENVELOPE LEAKAGE DIAGNOSTICS This buiding obtained compliance credit for: ❑ .Envelope sealing using diagnostic testing (CF -1 R) -Building Envelope Leakage (CFM @ 50 Pa) -Leakage level equivalent to an SLA of 3.0 from CF -1 R -Minimum Building Leakage equivalent to an SLA of 1.5 from CF -1R (CFM @ 50 Pa) Needed for Compliance (from CF -1R) Measured .Blowerdoor Test Results ❑ Yes ❑ No Is design infiltration less than the kA 3.0 equivalant (from CF -1 R)? Yes No Is mechanical ventilation installed? (Required if design is less than 3.0 SLA) Yes F'No Is measured leakage (without fans operating) less than minimum in the above Table (1.5 SLA from CF -1 R)? ❑ Yes R No Is mechanical supply ventilation installed to assure house,pressure does not go below minus 5 Pascal relative to outside ambient with all exhaust fans operating? _ Mechanical Ventilation - Fill in Table if mechanical ventilation is installed t Used for Compliance ( Measured ' (from CF -1 R) Actual ;Continuous Mechanical Ventilation (CFM , -Continuous Mechanical Supply Ventilation (CFM) Required to maintain -5 Pa if building envelope leakage is less than minimum (see above) -Total Power Consumption of Continuous Mechanical Ventilation (Watts) 2 ❑ This certifies that the building leakage was verified. When compliance credit is claimed for building leakage reduction below default assumptions, builder employees or subcontractors shall certify that they have verified that the building leakage level matches that used for compliance on the CF -6R and shall document the infiltration levels required for compliance and the tested infiltration values on the CF -6R.. This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] t I ests lgn' a u Date -Installing Suubcontrac or Co: ame Performed OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy , 1. When mechanical ventilation is required, CFM less than 0.047 CFM per square foot of conditioned floor area indicates failure to achieve compliance 2. As determined from label on fan or manufacturers literature. EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.51 1Page: 14 of 29 F FI INSTALLATION CERTIFICATE (Part 5 of 7) CF -6R 46 bite Address Permit- uf� tuber The following is an explanation of many of the input values required on this form: HVAC SYSTEMS Heating Equipment Type must be one of the following: Furnace: Gas (including Liquefied Petroleum Gases) or oil -fired central furnace & space heater Boiler: Gas or oil -fired boiler PckgHeatPump: Packaged central heat pump SplitHeatPump: Split central heat pump RoomHeatPump: Room heat pump LrgPkgHeatPump: Large packaged heat pump (>=65,000 Btu/hr output) Electric: Electric resistance heating (fixed HSPF = 3.413); radiant electric resistance (fixed HSPF = 3.55) CombinedHydro: Reference water heater under water heating systems below -CEC Certified Manufacturer Make & Model Number from applicable Commission approved appliance directory. -V of Identical Systems" is for those systems with the same efficiency, duct location, duct R -Value and capacity. -Efficiency from applicable Commission certified appliance directory. -Duct Location is attic, crawl space, CVC crawl space, conditioned space, unconditioned space or none. -Duct (or Piping) R -Value from Directory of Certified Insulation Materials and/or manufacturer's data. -Heating/Cooling Load refer to Commission approved load calculation procedure. -Heating/Cooling Equipment Capacity from the applicable Commission certified appliance directory. Note: location • elevations over 2,000 ft above sea level require a derating of output capacity (refer to manufacturer's literature). Cooling Equipment Type must be one of the following: SplitAirCond: 'Split system air conditioner PckgAirCond: Packaged air conditioner SplitHeatPump: Split system heat pump PckgHeatPump: Packaged heat pump RoomHeatPump: Room heat pump LrgPkgHeatPump: Large packaged heat pump (>=65,000 Btu/hr output). Substitute EER for SEER when SEER is not available. RoomAirCond: Room air conditioner. Minimum SEER varies* . LrgPkgAirCond: Large packaged air conditioner (>=65,000 Btu/hr output). Substitute EER for SEER when SEER is not available. EvapDirect: Direct evaporative cooling system. For compliance calculation purposes, fixed values: SEER = 11.0; duct location = attic; duct insulation R -value = 4.2 Evapindirect: Indirect evaporative cooling system. For compliance calculation purposes, fixed values: SEER = 13.0; duct location = attic; duct insulation R -value = 4.2 *Refer to California Energy Commission (CEC), publication Appliance Efficiency Regulations, P400-92-029 v, EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.51 Page: 15 of 29 INSTALLATION CERTIFICATE (Part 6 of 7) CF -6R 1 SI�e AddressPermit Number The following is an explanation of many of the. input,values required on this form: WATER HEATING SYSTEMS Distribution Systems: Refer to Residential Manual for more details. Standard: Standard - Supply prssure based system, no pumps Pipe Insulation: Pipe Insulation on all 3/4 -inch pipes "POU/HWR: Point of Use/Hot Water Recovery System Recirc/NoControl: Recirculation loop with no controls Recirc/Timer: Recirculation loop with a timer Recirc/Temp: Recirculation loop with temperature control Recirc/Time +. Temp: Recirculation loop with a timer and temperature control Recirc/Demand: Recirculation loop with demand control Water Heater Type Windows, sliding glass doors, french doors, skylights, garden windows, and Information Needed any door with more than one square foot of glass Operator Type; Energy Factor Recovery Efficiency Standby Loss Rated Input Storage Gas, Oil or Electric Yes ! No No No Heat Pump Yes No No No Instantaneous Gas No Yes No No • Instantaneous Electric Yes No No No Large Storage Gas No Yes Yes Yes Indirect Gas (Boiler) No Yes (AFUE) } No Yes FENESTRATION / GLAZING Fenestration: Windows, sliding glass doors, french doors, skylights, garden windows, and any door with more than one square foot of glass Operator Type; Slider, hinged, fixed U -Value: Installed U -Value must be less than or equal to value from CF -1 R OR Installed weighted. average U -Value for the total fenestration area is less.than or equal to value from CF -1 R SHGC: Installed SHGC must be less than or equal to value from CF -1 R OR Installed SHGC for the total fenestration area is less than or equal to value from CF -1 R + OR An interior shading device, overhang, or exterior shading device is installed consistent with the CF -1 R ShadingDevice: Include when the building complied using an interior shading device: blinds, opaque roller shades, blinds (do not list draperies), an exterior shading device: woven sunscreen, louvered sunscreen, low sun angle sunscreen, roll -down awning, roll -down blinds or slats (do not list bug screen), or an overhang (include depth in feet) y A EnergyPro 2.1 By EnergySoft User Number: 3665 , Job Number: 901.51 Page: 16 of 29 K] INSTALLATION CERTIFICATE (Part 7 of 7) CF -6R M bite Address Hermit Number The following'is an explanation of many of the input values required on the Diagnostic portion of this form (page 3 of 6): TYPE OF CREDIT Refer to Residential Manual Chapters 4 and 5 for more details: Reduced Duct Surface Calculated as the outside area of the duct. Areas must be measured and Area: verified by HERS rater. Improved Duct Location: Supply duct located in other than attic, as verified by location of registers- egisters(does not require HERS rater verification). (does Catastrophic Leakage: Pressure pan test reading'must be less than 1.5 Pascal at a house pressure of 25 Pascal. TXV: Access cover required to facilitate verification. Infiltration Reduction: Infiltration is measured without mechanical ventilation operating: Mechanical ventilation is required for very tight house construction'when credits for infiltration reduction using diagnostic testing are beng used for, achieving compliance. These very tight'houses are defined as those with SLA of less than 1.5. The compliance documentation (CF -1 R) will contain the measured CFM target .value from a blower door test at 50 Pascal pressure difference that represents this SLA of 1.5. Mechanical, ventilation is also required if the builder chooses to design the building to use mechanical ventilation and claims a credit for infiltration below an SLA of 3.0. The compliance documentation (CF -1 R) will contain the measured CFM target value that represents this 3.0 SLA. If the builder claims credit in a design for infiltration reduciton that is at an SLA of 3.0 or higher, and . the actual measured SLA is 1.5 or greater, then mechanical ventilation is , not required. Ifithe SLA in this case were below 1.5, then mitigation (such as mechanical ventilation) would be required. EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.51 Page: 17 of 29 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Gudmundson Residence (Guest House Addition) 5/19/00 SYSTEM NAME FLOOR AREA HVAC -1 614 Number of Systems 1 Heating System Output per System 22,800 Total Output (Btuh) 22,800 Output (Btuhlsgft) 37.1 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 39.1 Total Output (sgft/Ton) 307.0 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.30 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of 68.9 of Outside Air Q 0 cfm Supply Fan 800 cfm 68.9 OF 11.0 / 77.4 of Outside Air 0 cfm 74.9/63.3 of •4 68.9 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 903 15,251 1,773 1,162 19,011 0 763 951 0 0 0 0 0 0 0 0 0 763 951 16,776 1,773 20,912 LENNOX HP26-024-7P 15,042 5,822 14,995 Total Adjusted System Output 15,042 5,822 14,995 (Adjusted for Peak Design Conditions) Heating Coil TIME OF SYSTEM PEAK IAug 2 pm I Jan 12 am 86.4 of res at I Ime k Return Air Ducts V res at I ime Supply Air Ducts 85.3 of ROOMS 70.0 of 74.9 / 63.3 of 74.9 / 63.3 of 57.4 156.3 of * %� 0 -, C SuPPY I Air Ducts Supply Fan Cooling Coil 800 cfm Return Air Ducts 58.2156.7 of 54.8% R.H. ROOMS 74.0 / 63.0 of I EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.51 Page: 18 of 29 1 a IRO.OM LOAD SUMMARY ° "t PROJECT NAME r Gudmundson Residence (Guest House Addition) DATE 5/19/00 SYSTEM NAM c HVAC -1 FLOOR AREA 614. ROOM LOAD SUMMARY q ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME • ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Guest House Addition Guest House i l n 1 .903 15,251 1,773 903 15,251 1,773 1,1 62 19,011 t • e I I r • r • I 1 � y •II I •i t — ♦ f l I 1 r j t Y PAGE TOTAL • 903 15,251 1,773 1;162. 19,011 x TOTAL 903 15 1,162 19, EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.51 Page: 19 of 29 1 ROOM HEATING PEAK LOADS 11Gudmundsoln Residence Room Information Room Name Floor Area Indoor Dry Bulb Temperature } uest House Additioli) Design Conditions Guest House Addition Time of Peak 614 Outdoor Dry Bulb Temperature 70 OF 5/19/00 Jan 12 am 26 of - Conduction Area U -Value OT OF Btu/hr • luction 614.0 X X X X X X x x X X x X x x x x X x x X x AX X x X X X X x X X X x x X X X X x interior 0.0280 X X X X X x x" x X x X x X x x x ,x X x y' A x X X X X X X X x X X X X' X X x X X x another 44.0 = = = = = = _ _ = — = — — _ _ = = = c = — _ _ 757 1,050.7 0.0592 44.0 2,737 ' 48.0 0.8500 44.0 1,795 85.0 0.8700 44.0 3,254 6.3 0.7200 44.0 199 perimeter= 125.0 44.5 5,562 i through an surface to WQRL.Total' F14 304 Infiltrationt 1.00 x 1.072 x 614]x 9.75 x 1.00 / 6f -x = 4,707 L c e ule it Sensible Area ei ing eig t C J oT. racoon t • TOTAL HOURLY HEAT LOSS FOR ROOM 19,01111 EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.51 Page: 20 of 29 RESIDENTIAL ROOM COOLING LOAD SUMMARY Gudmundson Residence (Guest House Addition) 5/19/00 • Project Title Date Room Name Guest House Addition \1 • Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Double Mtl Uncoated Default Double Mtl Uncoated Default Double Mtl Uncoated Default J Area U -Value 1 0.0592 0.8500 0.8700 0.7200 740F 1120E 380F DETD 1 Btu/hr X 55.0 = 946 X 34.6 = 2,153 X 38.0 = 1,550 X 38.0 = 2,810 X 38.0 = 172 X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 7,s31 Items shown with an asterisk (*) denote conduction thri5h an interior surface to another room. �ded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 1 (North) 2 (North) 3 (East) 4 (East) 5 (East) 6, (South) 7 (South) 8 (West) 9 (West) 1 12.0 ( 0.0 x1 X x x X x x x X X + + + + + + + + + + 48.0 X X X X X x x X x X 15) x X x X X X X x X )X 0.757 = = = = = = = = _ 545 ( 0.0 1 16.0 15) 0.757 182 ( 0.0 1 12.0 48) 0.757 436 ( 0.0 1 6.3 48) 0.757 228 ( 0.0 1 4.5 48) 0.757 164 ( 12.4 1 3.6 62) 0.757 310 (-12.4 15 3.6 62) 0.757 310 ( 0.0 1 4.5 62) 0.757 211 ( 0.0 1 16.0 6) 0.757 751 ( Sched. Page Total 3,136 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 614 X 0.000 Watts/sgft x 3.41 Btuh/Watt = o Occupants 1.00 X 614 X 0 Btuh/occ. / 250 sqft/occ. = 0 Receptacle 1.00 X 614 X 0.200 Watts/sqft x 3.41 Btuh/Watt = 419 Process 1.00 x 614 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration�1�600L x 1.072 x s1a x s.7s x 1.00 /60 38 = a,os5 le Atr Sensible Area eihng eight KC o Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15.25111 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x s1a x 0 Btuh/occ. / 250 sgft/occ. = o Receptacle 1.00 x s1a x 0.000 Watts/sgft x 3.41 Btuh/Vllatt = 0 Process 1.00 x 61a x 0.000 Watts/sgft x1 3.41 Btuh/Watt = 0 Infiltration: [ 1.00 x a,8os x 61a x 9.75 x 1.00 /60] 0.00370 = 1,773 c e u e Air Latent Area C11 nI g Refgh- AC pW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,773 EnergyPro 2.1 By EnergySoft User Number: 3665 Job Number: 901.51 Page: 21 of 29 • 10 ENNOXCOILS — BLOWER COIL UNITS UL LISTED :.0i MULTI—POSITION BLOWER COIL UNITS Bulletin#210106 *12,600 to 60,000 Btuh (3.7 to 17.6 kW) Cooling Capacity November 1995 *11,500 to 58,000 Btuh (3.4 to 17.0 kW) Heat Pump Heating Capacity 2.5 to 30.0 kW Optional Electric Heat *ARI Standard 210/240 Ratings With Matching Outdoor Unit Applications U • 1-1/2 to 5 ton (5.3 to 17.6 kW) nominal sizes. • Multi -position (up -flow, down -flow or horizontal) applications. C ® ISO9002REGISTERED • Applicable to expansion valve systems in cooling WORLD CLASS DUALITY applications and check and expansion valve systems in LISTED heat pump applications. • Wide range check and expansion valve factory installed. • See Condensing Unit bulletins in section Cooling Units — o.<. Condensing Units for cooling capacities. • See Heat Pump Outdoor Unit Bulletins in section Heat ' Pumps — Matched Remote Systems for cooling and heating capacities. • Optional field .installed electric heaters available in V `~''1• several sizes for additive heating capacity. • Filter furnished. 64 • Optional additive base available for models with electric heat installed in down -flow position on combustible floors. '« CB30M Warranty Up -flow Position • All covered components — five years (residential (With Optional Electric Heat) applications), one year (non-residential applications). Completely Tested and Approved t • Tested with matching condensing and heat pump units in the Lennox Research Laboratory environmental test room in accordance with ARI Standard 210/240-89. • Optional electric heaters rated in accordance with U.S. Department of Energy (DOE) test procedures and Federal Trade Commission (FTC) labeling regulations. • Blower performance data according to unit tests conducted in Lennox air test chamber. • Blower -coil units are U.L. Listed to U.S. and Canadian safety standards and components within are bonded for grounding to meet safety standards for servicing required by CEC and NEC. r -•. • Units developed in accordance with ISO 9002 quality standards. Cabinet G'. x • Constructed of heavy gauge galvanized steel. C., • Completely insulated with thick fiberglass insulation. •pre -painted steel cabinets have mildly textured enamel finish with primer coat on unpainted side of all panels. •Units are shipped in one piece but may be disassembled into 4 two separate sections for ease of installation in tight applications. See dimension drawings. r • Thick rubber gasket between sections provides air tight seal. • No external screw heads on sides of cabinet for tight CB30M installations without damage to walls or woodwork. • Removable panels provide complete service access. Horizontal Left Hand Position • Electrical inlets provided in sides and top of cabinet. See (With Optional Electric Heat) dimension drawings for locations. Typical Applications With Optional Electronic Air Cleaner Uown-Flow Installation P The maple leaf symbol in this bulletin denotes Canadian only usage where applicable ©1995 Lennox Industries Inc. NOTE — Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. • i� I SPECIFICATIONS Model Number CB30M-21/26 CB30M-31 CB30M-41 CB30M-46 CB30M-51 CB30M-65 Evaporator Coil Net face area -ft.2 (m2) 3.11 (0.29) 3.56 (0.33) 4.44 (0.41) 4.44 (0.41) 5.0 (0.46) 5.0 (0.46) Tube outside diameter - in. (mm) 3/8 (9.5) 3/8(9.5) 3/8(9.5) 3/8(9.5) 3/8(9.5) 3/8(9.5) Number of rows 2 2 2 3 3 3 Fins per inch (fins per m) 14 (551) 14 (551) 14 (551) 12 (472) 12 (472) 12 (472) Suct. (vapor) line conn. - in. (mm) sweat 5/806) 3/4(19) 3/4(19) 7/8(22.2) 7/8(22.2) 1-1/8(28) Liquid line conn. - in. (mm) sweat 3/8(9.5) 3/8(9.5) 3/8(9.5) 3/8(9.5) 3/8(9.5) 3/8(9.5) Condensate drain connection (fpt) - in. (mm) (20/409) (19) (2) 3/4 (19) (2)3/4(19) (20/409) (19) (2)3/4(19) (2) 3/4 (19) Nominal cooling capacity -tons (kW) 1-5-2 (5.3-7.0) 2.5 (8.8) 300.6) 3.5 (6.3) 4(14.1) 507.6) Refrigerant HCFC -22 Blower wheel nominal diameter x width - in. (mm) 10 x 7 (254 x 178) 10 x 8 (254 x 203) 11 x8 (279 x 203) 11 x 8 (279 x 203) 11-1/2 x 9 (292 x 229) 12 x 9 (305 x 229) Blower motor output - hp (W) 1/5(149) 1/3(249) 1/3(249) 1/3(249) 1/3(249) 1/2(373) ttNumber and size of filters in. (1)15x20x1 (1)20x20x1 (1)20x24x1 mm (1) 381x508x25 (1) 508 x 508 x 25 (1) 508 x 610 x 25 Electrical characteristics (60hz) 208/230v-1 ph 208/230v-1 ph **460v - 3 ph 208/230v-1 ph 208/230v - 1 ph ***460v - 3 ph 575v - 3 ph Shipping weight - lbs. (kg) 1 package 136 (62) 157 (71) 177 (80) 181 (82) 206 (93) 206 (93) s Optional Accessories (Must Be Ordered Extra) : Side Return Unit Stand (Up -Flow Only) Catalog number 45K31 45K32 Ship. wt. - lbs. (kg) 5 (2) 6 (3) Wall Hanging Bracket Kit - Shipping weight - lbs. (kg) 45K30 - 3 (1) (Up -Flow Only) Down -Flow Combustible Base - Ship. wt. - lbs. (kg) 34.172 - 8 (4) 3403 - 8 (4) Electric Capacity (1 phase) ECB29-2.5 *Output - Btuh (kW) 9,500 (2.8) 10,000 (2.9) - - - - - - - - - - - - - - - - tA.F.U.E. 100% 100% ---- ---- ---- ---- ECB29-5, ECB29-5CB *Output - Btuh (kW) 18,000 (5.3) 18,500 (5.4) 18,500 (5.4) 19,000 (5.6) 19,000 (5.6) - - - - tA.F.U.E. 100% 100% 100% 100% 100% - - - - _ ECB29-8, ECB29-8CB *Output - Btuh (kW) 28,000 (8.2) 28,500 (8.4) 28,500 (8.4) 29,000 (8.5) 29,000 (8.5) 30,500 (8.9) tA.F.U.E. 100% 100% 100% 100% 100% 100% ECB29-10, ECB29-10CB *Output - Btuh (kW) 35,000 (10.3) 35,500 (10.4) 35,500 (10.4) 36,000 (10.5) 36,000 (10.5) 37,000 (10.8) tA.F.U.E. 100% 100% 100% 100% 100% 100% ECB29-12.5CB *Output - Btuh (kW) - - - - 44,000 (12.9) 44,000 (12.9) 44,500 (13.0) 44,500 (13.0) 45,500 (13.3) tA.F.U.E. - - - - 100% 100% 100% 100% 100% ECB29-15CB *Output - Btuh (kW) - - - - 52,500 (15.4) 52,500 (15.4) 53,000 (15.5) 53,000 (15.5) 54,000 (15.8) tA.F.U.E. - - - - 100% 100% 100% 100% 100% ECB29-2006 *Output - Btuh (kW) - - - - - - - - 69,500 (20.4) 70,000 (20.5) 70,000 (20.5) 71,500 (20.9) tA.F.U.E. - - - - - - - - 100% 1000/0 100% 100% ECB29-25CB *Output - Btuh (kW) - - - - - - - - - - - - - - - - 87,000 (25.5) 88,500 (25.9) tA.FLI.E. --- ---- ---- ---- 100% 100% EC1329-3006 *Output-Btuh(kW) ---- ---- . ---- ---- ---- 105,500 (110.9) tA.F.U.E. ---- ---- ---- ---- 100% THnnuai rues utmzation ttticiency based on U.S. UUt test procedures and according to FTC labeling regulations. ttDisposable frame type filter. *Includes additional blower motor heat capacity. **Blower motor is 460v - 1 phase. Optional electric heat is 460v - 3 phase. ***Blower motor is 460v single phase. 575v electric heaters are shipped with step-down transformer for use with 460v units (CB30M-51 & CB30M-65 models only). CB30M / Page 3 ► DIMENSIONS — inches lmm) • 3/4 119) 0. 1ER • SUPPLY AIRDETAIL OF PIPING PLATE ------- —� /43 OPENING rat=1/8,1291 _-- SUCTION:UNE 43/8'„ CONDENSATE ••.v::.. ;: 111 DRAINS (2) 3/4 (Horizontal) 16 281 (19), :v r[ -.'::f} r� _'"s":• ',e�?f• '1•f' CONDENSATE �• h'r. I%y�' ' '� j� y -O" DRAINS (2) 5.3 8 a �.. '°• IUp•Flow and .1137► + ; ' Down -flow) + -. ) LINE VOLTAGE LOW VOLTAGE "_ I INLETS - INLETS _ I 1 (Top and Left Side) (Top and I 1-3/4 Right Side)' TOP VIEW 1441 3-1/2 last r —� — B CB30M-41 CB30M-46 s/8 C I mm �•��. -�:� inch mm 1161 ' mm O i'::!Ilallllllllqui ,q �y'�«� �• IIIIIIIIIIIIIIIII �.µl mm A 45-1/4 1149 49-1/4 1251 51, 1295 52-1/2 1334 58.1/2 1486 B 161/4 /t/, ��4I r\ 21-1/4 540 21-1/4 G OPTIONAL/ ELECTRIC 540 x/,•�y�(BLOWER) 6I 540 I. IR FLOW 20-5/8 524 HEAT 524 p1my.\ffstx3 575 ` 575 24-58 (Field Installed) D a µ \ 'Ki rs 375 19-3/4 502 19-3/4 502 19-3/4 502 19-3/4 n•,•«.•••t� ': '�ix+�.`'- E / 19 r�,A:.•Ai...fs.Rid.: i1 i}u: 21 T. C-r Fk] 4f J, S I;I A 4 i/PIPING `n``'rI`I SUCTION.(.? riCOVL}}Y:I: H LINELIQUID C LINE I � ' I I r*- FILTER FILTER ACCESS F 1 5/8 X(25) list FRONT VIEW 5/8 i Return Air —1E 5!e 1161 SIDE VIEW CB30M DOWN -FLOW POSITION DETAIL OF PIPING PLATE-- Model No. C830M-21/26 CB30M-31 CB30M-41 CB30M-46 C830M-51 CB30M-65 inch mm inch mm inch mm inch mm inch. mm A 45-1/4 1149 49-1/4 1251 51, 1295 52-1/2 1334 58.1/2 1486 B 161/4 413 21-1/4 540 21-1/4 540 21-1/4 540 21-1/4 540 C 20-5/8 524 20-5/8 524 22-5/8 575 22-5/8 575 24-58 625 D 14-3/4 375 19-3/4 502 19-3/4 502 19-3/4 502 19-3/4 502 E 19 483 19 483 21 533 21 533 23 584 F 15 351 20 508 20 508 20 508 20 508 G 24-5/8 625 24-5/8 625 26-38 670 27-7/8 708 27-78 708 H 2O-5/8 524 24-5/8 625 24.5/8 625 24-5/8 625 30.5/8 778 Model No. CB30M-21/26 C83OM-31 ' CB30M-46 5/8 SUCTION UNE' I "': mm `•4 3/8; •, 1111-u; CONDENSATE (16)LIQUID.• e LINE ,+ �Y �''""''�' d x i z, DRAINS (2) (Horizontal) 5/8 (16) "tt jay •, , 5/8 1161 2 5fr v: 1251 51 F 52-1/2 IE lstl 58-1/2 1486 B RETURN 413 21-1/4 . CONDENSATE 540 ' E .,, ..AIR> -P OPENIN(al 540 ='1 v-,.' �' 5.3/83r: DRAINS (2) (Up -Flow end Model No. CB30M-21/26 C83OM-31 CB30M-41 CB30M-46 C83OM-51 C830M-65 inch mm inch mm inch mm inch mm inch mm A 45-1/4 1149 49-1/4 1251 51 1295 52-1/2 1334 58-1/2 1486 B 16-1/4 413 21-1/4 540 21-1/4 540 21-1/4 540 21-1/4 540 C 20-5/8 524 20-58 524 22-5/8 575 22-58 575 24-58 625 D 14-3/4 375 19-3/4 502 19-3/4 502 19-3/4 502 19-3/4 502 E 19 483 19 483 21 533 21 533 23 584 F 15 351 20 508 20 508 20 508 20 508 G 24.5/8 625 24 5/8 625 26 38 670 27-7/8 708 27-78 708 H 2O-5/8 524 24-5/8 625 24-5/8 625 24-5/8 625 30-58 778 11110, CB30M / Page 12 10, -k� LOW VOLTAGE (Right Side) ' LINE VOLTAGE (Left Side) 3r.'t nuuuninwi;-•.I ;:i .,M1\ n�:.: IIIIIIIIIIIIIIIII P. -- 5/8 3/4 Supply Air T « Supply Air D 3/a 3/4 11.1/16 5/8 1191 12811 (16) FRONT VIEW SIDE VIEW _, . /4 .. :,1701 s r 0 1 1251 _I I 1-3/41-W TOP VIEW (44) 3.1/2(89) --� T-- �--- B ACCESS // C—►{ / s� :e f e I / FILTER �- • -yam., i s I1 1;I �SUCTION PIPING' -• / PLATE LINE .\ _ _ _ LIQUID - -. - :.µ,-.•. •. • :c -:z•: ;'I-•7;'�,^ `1!`13=,, LINE •,�t:;,},i�rK�_. •�,ct.. ELECTRAC �-r rl •�\•u '- AIR FLOW 'I;,r:yt. ( HEAT (Field G Installed) ` 1 BLOWER` n `r(.•tp� �U rI -k� LOW VOLTAGE (Right Side) ' LINE VOLTAGE (Left Side) 3r.'t nuuuninwi;-•.I ;:i .,M1\ n�:.: IIIIIIIIIIIIIIIII P. -- 5/8 3/4 Supply Air T « Supply Air D 3/a 3/4 11.1/16 5/8 1191 12811 (16) FRONT VIEW SIDE VIEW It W11. ELITE 13 TM HEAT PUMP OUTDOOR " Up To 14.70 SEER *18;600 to 59,400 Btuh (5.4 to 17.4 M) Cooling Capacity *17,600 to 56,200 Btuh (5.2 to 16.5 M) Heating Capacity *ARI Standard 210/240 and DOE Certified Ratings' Bulletin #210023 September 1996 T Supersedes April -1996 w Application — Energy efficient HP26 outdoor units are designed for ap- U Plications with remotely located indoor blower -coil units or indoor add- �� Uon coils in FM21 installations. Outdoor units are equally suited for instal - C ® L lation on a slab at grade level or on a rooftop. A variety of matching up -flow, down -flow and horizontal blower powered indoor units, with CERTIFICATION APPLIES ONLY LISTED LISTED optional supplemental electric heat, provide selective sizing and instal - MEN THE COMPLETE lation versatility. For FM21 applications, see bulletin indexed in this SYSTEM IS LISTED tab section. For indoor unit data, see section, Coils -Blower Coil Units. "T"A' Outdoor units are test operated at the factory to insure proper operation and shipped ready for installation. Installer has only to locate unit and t make refrigerant line and electrical connections. Typical Application Approvals—Units have been tested with matching indoor units in the Lennox Research Laboratory and rated according to U.S. Department of Energy (DOE) test procedures and:in accordance with ARI Standard 210/240-94. In addition, units have been sound rated in the Lennox re- verberant sound test room in accordance with test conditions included in ARI Standard 270-95.'Units and components within are'bonded for grounding to meet safety standards for servicing required by U.L., •R. N.E.C. and C.E.C. Units are U.L. and U.L.C. listed. Equipment Warranty—The compressor has a limited warrantyforten years in residential installations and five years in non-residential installations. All other covered components have a limited warranty for five years. Refer to Lennox Equipment Limited Warranty included with the unit for specific details. Copeland's Compliant Scroll' Compressor — High efficiency com- pressorfeatures durability, steady uniform suction flow, constantdis- charge flow, high volumetric efficiency, quiet operation and the abil- ity to start under any system load. Use of the scroll compressor, eliminates the need for accumulator, crankcase heater, start capacitor and start relay. The compliant scroll type compressor is simplecom- pression concept design consisting of two involute spiral scrolls matched together to generate a series of crescent-shaped gas pock- ets between them. During compression, one scroll is stationarywhile the other is allowed to orbit, not ro- tate, around the fixed one. As this motion occurs; gas is drawn into the outer pocket sealing off the open pas- sage. As the spiral movement contin- ues, the pockets between the scrolls are slowly pushed to the center of the scrolls while simultaneously being re- duced in volume. When the, pocket reaches the center, the gas is now at high pressure and is forced out of a port located in the center of the fixed scroll. During compression, several pockets are beingcompressed si- multaneously resulting in a smooth, nearly continuous compression cycle. , Continuous flank contact, maintained by %- centrifugal force, minimizes gas leakage. and maxi- mizes efficiency. The scroll compres- sor is tolerant to the effects of liquid slugging arld contaminants. Should this occur, the scrolls separate and allow the liquid or contaminants to be worked to the center and discharged. Low gas pulses during com- pression minimize operational sound level. Factory installed muffler in discharge line, external to the compressor, provides additional sound reduction. Motor is internally protected from excessive cur- rent and temperature. Compressor is installed in the unit on resilient rubber mounts, assuring vibration free operation. 0 The maple leaf symbol in this bulletin denotes Canadian only usage where applicable ©1996 Lennox Industries Inc. NOTE — Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability..' Ll 4C. rARIRATINGS Unit Size *ARI Standard 210/240 Ratings gt ""Check Cool. Cap.9• High Low Htg. Total SEER Cool. Total High 4HSPF High Total Low Low Model No. *Sound IHtg.ndoor Units and Expansion Rating No. Btuh Btuh' (EER) C.O.P. Htg. IV Htg' lve Kit (db). (kW) Btuh Watts Watts (Re ion V) g C.O.O.ion Watts O.P. Required 4 (kW) (kW) 18,600 17,800 11,400 1805 12.00 302 1695 7'15 310 1555 2 Blower of nit (5.4) (5.2) (3.3) (10.30) . (6.35) . .17 CB29M-21/26 (Multi -Position) 18,800 17,800 111,400 1825 12.00 3.02 1705 7'10 3.08 1565 2.15 Blower Coil Unit (5.5) (5.2) (3.3) (10.30) (6.30) CB29M-31 (Multi -Position) 19,600 18,000 11,400 1820 12.50 3.00 1640 7'40 323 1525 2.22 Blower Coil Unit *Factory (5.7) (5.3) (3.3) (10.75) (6.50) . C1330M-21/26 (Multi -Position) Installed 20,000 18,000 11,400 1795 13.00 3.26 1595 7'50 331 1485 2 Blower Coil Unit (5.9) (5.3) (3.3) (11.15) (6.55) . .26 CB30M-31 (Multi -Position) 18,800 (5.5) 18,000 (5.3) 11,800 (3.5) 1815 12.10 (10.35) 3.03 1690 7'40 (6.70) 3.12 1505 2.32 Q Blower Coil Unit CVP10-26/EC10Q3 (Up -Flow) 18,800 17,800 11,400 1815 12.00 3.03 1710 7'10 3.07 1570 2.15 IndoorCoil(AFM21) Ton (5.5) (5.2) (3.3) (10.35) (6.30) C26-21(FC) (Up -Flow) 1.5 HP 19,200 18,000 11,400 1820 12.10 3.09 1685 7.20 3.14 1560 2.17 Indoor Coil (AFM21) (72) (72) (5.6) (5.3) (3.3) (10.55) (6.35) C26-26(W)(FC) (Up -Flow) 20,000 18,000 11,400 1830 1(12.6 0 3.21 1650 7'30 3.20 1540 2.19 Indoor Coil (AFM21) (5.9) (5.3) (3.3) 10.95) (6.40) C26-31(W)(FC) (Up -Flow) 18,600 17,800 11,400 1815 11'70 3.00 1750 7'00 2.99 1595 2.11 Indoor Coil (AFM21) (5.4) (5.2) (3.3) (10.25) (6.20) CR26-21 (Down -Flow) LB -85759F 19,800 17,800 111,400 1825 12.50 3.18 1670 7.25 3.15 1545 2.18 Indoor Coil (AFM21) (56J19) (5.8) (5.2) (3.3) (1085) (6.35) CR26-31 (Down -Flow) 18,800 17,600 11,200 1815 11. 80 303 1740 7'00 298 1590 209 Indoor Coil (AFM21) (5.5) (5.2) (3.3) (10.35) . (6.15) . . CH23-21 (Horizontal) 18,600 17,800 11,200 1815 12.00 3.00 1710 7'05 3.05 1575 2.12 Indoor Coil (AFM21) (5.4) (5.2) (3.3) (10.25) (6.20) CH23-31 (Horizontal) 19,400 17,800 11,400 1825 12.20 3.12 1665 7'20 3.16 1560 2.14 Indoor Coil (AFM21) (5.7) (5.2) (3.3) (10.65) (6.30) CH23-41 (Horizontal) 22,200 22,000 14,400 2170 11.85 2 99 2000 7' 85 332 1825 2 Blower Coil Unit (6.5) (6.4) (4.2) (10.20) (6.85) . .33 CB29M-21/26 (Multi -Position) 23,000 22,600 14,400 2190 12.10 3.08 2000 7'80 3.31 1830 2.32 Blower Coil Unit (6.7) (6.6) (4.2) (10.50) (6.80) CB29M-31 (Multi -Position) 23,200 (6.8) 22,800 (6.7) 14,600 (4.3) 2210 12.10 (10.50) 3.08 1975 8'00 (6.90) 3.38 1825 2.34 Blower Coil Unit CB29M-41 (Multi -Position) •Factory 24,000 22,800 14,400 2190 12.70 3.21 1940 8.05 3.45 1795 2.37 Blower Coil Unit Installed (7.0) (6.7) (4.2) (10.95) (7.00) CB30M-21/26 (Multi -Position) 24,400 (7.1) 22,400 (6.6) 14,200 (4.2) 2125 13.40 (11.45) 3.36 1840 8'25 (7.10) 3.60 1710 2.44 Blower Coil Unit C630M-31 (Multi -Position) 22,800 (6.7) 22,600 (6.6) 114,200 (4.2) 2195 12'05 (10.40) 3.04 1980 7'80 (6.80) 3.35 1825 2.31 0Blower Coil Unit CVP10-26/EC10Q3 (Up -Flow) 2 Ton 22,400 (6.6) 22,600 (6.6) 14,600 (4.3) 2195 11.80 (10.20) 2.99 2005 7'80 (6.85) 3.32 1835 2.33 Indoor Coil (AFM21) HP26-024 C26-21(FC) (Up -Flow) (72) 23;000 (6.7) 22,800 (6.7) 14,600 (4.3) 2195 12.10 (10.45) 3. 06 1970 8' 00 (6.95) . 341 1815 236 . Indoor Coil (AFM21) C26 -26(W)( -FC) (Up -Flow) 24,000 22,800 14,400 2200 12.70 3.19 1925 8.10 3.48 1795 2.38 Indoor Coil (AFM21) (7.0) (6.7) (4.2) (10.90) (7.00) C26-31W(FC) (Up -Flow) 22,000 22,600 14,400 2185 11.50 2.95 2050 7'70 3.23 1860 2.29 Indoor Coil (AFM21) (6.4) (6.6) (4.2) (10.05) (6.75) CR26-21 (Down -Flow) LB -85759F 23,800 22,800 14,400 2200 12.50 3.17 1960 8'00 3.42 1805 2.36 Indoor Coil (AFM21) (56J19) (7.0) (6.7) (4.2) (10.80) (6.95) CR26-31 (Down -Flow) 22,600 22,200 14,200 2190 11.80 3 2035 7'60 322 1860 226 Indoor Coil (AFM21) (6.6) (6.5) (4.2) (10.30) .02 (6.75) . . CH23-21 (Horizontal) 22,800 (6.7) 22,400 (6.6) 14,400 (4.2) 2190 12. 00 (10.40) 3 .05 2000 7'75 (6.80) . 330 1835 230 . Indoor Coil (AFM21) CH23-31 (Horizontal) 23,600 (6.9) 22,600 (6.6) 14,400 (4.2) 2195 12'35 (10.75) 3.15 1935 8'00 (6.95) 3.44 1805 2.35 Indoor Coil (AFM21) CH23-41 (Horizontal) .,.,�,w aan iy 1-411 ci - acwivance wnn rest cunumons mcivaea in An[ Jtanaara Z/u. 4Heating Seasonal Performance Factor. `A1 *Rated in accordance with ARI Standard 210/240 with 25 ft. (7.6 m) of connecting refrigerant lines; Cooling Ratings - 95°F (35°C) outdoor air temperature and 80°F (27°C) db/67°F (19°C) wb entering indoor coil air. High Temperature Heating Ratings- 47°F (8°C) db/43°F (6°C) wb outdoor air temperature and 70*F (21°C) db entering indoor coil air. Low Temperature Heating Ratings- 17*F db/150F wb outdoor air temperature and 70°F (21°C) db entering indoor coil air. •Furnished as standard with coil unit. *"Kit is required and must be ordered extra, unless shown as factory installed. AFM21 Heat Pump Control - Use coil listed with any Lennox furnace that meets system design requirements. See FM21 page in this section for additional data. NOTE - Shaded area denotes most popular blower coil combination. HP26 / Page 3 pop. C_ ELECTRICAL DATA Model No. HP26-018 HP26-024 HP26-030 HP26-036 HP26-042 Line Voltage data 20872-30v 60hz-1ph 72-0782-30v 60hz-1ph --20782-30,, 60hz-1ph 208/230, 60hz-1ph 208 230, 60hz-3ph 208/230, 60hz-1ph 208 230, 60hz-3ph Compressor Rated load amps 8.4 10.3 13.5 16.1 10.3 18 12.5 Power factor .96 .96 .96 .96 .82 .97 .82 Locked rotor amps 47 56 72.5 88 77 104 88 Outdoor Coil Fan Motor Full load amps 0.8 0.8 1.1 1.1 1.1 1.1 1.1 Locked rotor amps 1.6 1.6 2.0 2.0 2.0 2.0 2.0 Rec. max. fuse or circuit breaker size (amps) 15 20 30 35 20 40 25 *Minimum circuit ampacity 11.3 13.7 18 21.2 14 23.6 16.8 nCICr LV IVdLLVndr Vr _dnaardrr CICGUIGaI uuuL manual to aetermine Wire, ruse ana alsconnect size requirements. NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. ,T ELECTRICAL DATA Model No. Line Set Line Length Model No. ft. m HP26-048 Vapor Line (o.d.) in. HP26-060 in. Line voltage data 208/230, 60hz-1ph 208 230v 60hz-3ph 460, 60hz-3ph 208 230, 60hz-1ph _20_8T2 3 _0v 60hz-3ph 460v 60hz-3ph Compressor Rated load amps 23.8 13.5 7.4 28.9 17.4 9.0 Power factor .94 .87 .87 .94 .85 .85 Locked rotor amps 129 99 49.5 169 123 62 Outdoor Coil Fan Motor Full load amps 1.7 1.7 1.1 2.3 2.3 1.1 Locked rotor amps 3.8 3.8 2.2 4.8 4.8 2.2 Rec. max. fuse or circuit breaker size (amps) 50 30 15 60 40 20 *Minimum circuit ampacity 31.5 18.6 10.4 38.5 24.1 12.4 -nUICr W INdlrUrldl Ur _dndUldo CICGUIGaI uaue manual to aetermine Wire, ruse ana alsconnect size requirements. NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. I WIRING r-----, r1 r DISCONNECT, IOptionaq THERMOSTAT SWITCH DISCONNECT SWITCH LENNOX A - Two Wire Power (see Electrical Data) L _ - - J L (By Others) J L IBL Others) J OPTIONAL "�- 1-- SUPPLEMENTAL B - Two or Three Wire Power (size to heater capacity) ELECTRIC HEAT r OPTIONAL 1 OUTDOOR F L THERMOSTAT J r DISCONNECT 1 LENNOX I SWITCH OUTDOOR L(By Others) UNITC L00 INDOOR UNIT REFRIGERANT LINE KITS Outdoor Unit Model No. Line Set Line Length Model No. ft. m Liquid Line (o.d.) Vapor Line (o.d.) in. mm in. mm HP26-018 L15-26-20 20 6 3/8 9.5 5/8 15.9 L15-26-25 25 8 L15-26-35 35 11 L15-26-50 50 15 HP26-024 HP26-030 HP26-036 L15-41-20 20 6 3/8 9.5 3/4 19 L15-41-30 30 9 L15-41-40 40 12 L15-41-50 50• 15 HP26-042 HP26-048 L15-65-30 30 9 3/8 9.5 7/8 22.2 L15-65-40 40 12 L15-65-50 50 15 HP26-060 *Not available 3/8 1 9.5 1-1/8 22.2 I— r - - nciiiyerdni 1111e se[ snouia not exceed nu it. i iom) In any mStallatlon. *Field fabricate. C - Two Wire Power (size to indoor coil blower motor) D - Two Wire Low Voltage - 18 ga. minimum E - Eight Wire Low Voltage - 18 ga. minimum - with Electric Heat - Ten Wire Low Voltage with Optional Outdoor Thermostat F - Four Wire Low Voltage - 18 ga. minimum G - Three Wire Low Voltage - 18 ga. minimum - Field Wiring Not Furnished - r. All wiring must conform to NEC or CEC and local electrical codes. INSTALLATION CLEARANCES inches (mm) NOTE -48" (1219 mm) clearance required on top of unit. *NOTE -One side of coil may be 12 (305) inches. HP26 / Page 7 jo. DIMENSIONS — inches (mm) INLET AIR i PCOMPRESSP 2 (51) i .0 B 11, � SERVICE ACCESS INLET a AIR INLET Q AIR COIL DRAIN OUTLETS TOP VIEW (Around perimeter . of base) ELECTRICAL INLETS 44 C BPI DISCHARGE AIR VAPOR LINE INLET '0., nO o- - 4-1/2 (114) o- D ;2=9/161 LIQUID LINE INLET LJ 2-3/4 4 F _� 4 (70) (102) (102) E 10 6-1/16-00- 1-3/8 (154) (35) SIDE VIEW Model No. A B C D E F G H J K in. 27-7/8 25-7/8 29-7/8 12-1/4 22-7/16 14-7/16 22-1/8 16-3/4 2-7/8 5-1/2 HP26-018 HP26-024 mm 708 657 759 311 570 367 562 425 730 140 in. 30-7/8 32-1/8 34-1/16 12-3/4 26-5/8 18-5/8 28-1/8 17-1/4 3-7/8 7-1/2 HP26-030 HP26-036 mm 784 816 865 324 676 473 718 438 98 191 in. 34-7/8 32-1/8 34-1/16 13-3/4 26-5/8 18-5/8 28-1/8 18-1/4 3-7/8 7-1/2 HP26-042 mm 886 816 865 349 676 473 718 464 98 191 in. 44-7/8 32-1/8 34-1/16 14-1/4 26-5/8 18-5/8 28-1/8 18-3/4 3-7/8 7-1/2 HP26-048 mm 1140 816 865 362 676 473 718 476 98 191 HP26-060 0 HP26 / Page 8 ► �7]