Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-3889 (SFD)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 c&ht 4 4 0" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: C_05-00003889 Property Address: • 81566 ULRICH DR APN: 764-270-999-97 -300234- Application descriptionDWELLING - SINGLE FAMILY DETACHED Property Zoning: A MEDIUM HIGH DENSITY RES Application valuation: 1706'39 Applicant: _�rchitect or Engineer: -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business an Professionals Code, and my License is in full force and effect. License Lins No.: �6�7228285 Date: ontractor: V Wv J OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or, my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(i) licensed pursuant to the Contractors' State License Law.). 1_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: -1 Lender's Address: N /� LQPERMIT Owner: SHEA LA QUINTA C/O JEFF MCQUEEN 8800 N GAINEY CENTER 350 SCOTTSDALE, AZ 85258_ Contractor: D SHEA HOMES, INC. 81260 AVENUE 62 LA QUINTA, CA 92253 (760)777-6005 Lic. No.: 672285 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/06/05 e D nr.7 14 2005 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier AMERICAN HOME Policy Numbe 1247619 I certify that, in the perfor nce of the ybe ich this permit is issued, I shall not employ any person in any manner s s to limtheworkers' compensation laws of California, and agree that, if I com suworkers' compensation provisions of Section 3700 of theJ�ebCode, sh I f rth ,.,;,h rhnse provisions. Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 -OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. . 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or c ssation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and stat aI bove infor tion is correct. I agree to comply with all city and county ordinances and state laws re g g constru ion, and hereby authorize representatives of this cou tytoaeruponthe above -me toned ofor ins c OM Date: cure (Applicant or Agent): Application Number . . . . . 05-00003889 Structure Information Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/CONG <=10 Flood Zone . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC FIRE SPRINKLERS NO GARAGE SQ FTG 576.00 PATIO SQ FTG 177.00 NUMBER OF UNITS 1.00 ---------------------------=------ 1ST FLOOR SQUARE FOOTAGE ------------------------------------------ 1943.00 Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 888.00 Plan Check Fee 144.30 Issue Date . . . . Valuation 170639 Expiration Date 3/05/06 Qty Unit Charge Per Extension BASE FEE 639.50 71.00 3.5000 ----------7-----------7----------------------------------------------------- THOU BLDG 100,001-500,000.' 248.50 Permit . . . MECHANICAL Additional desc . Permit Fee 70.50 Plan Check Fee 4.41 Issue Date Valuation . . . . 0 Expiration Date 3/05/06 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 .2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 2.00 6.5000 EA MECH VENT FAN 13.00 1.00 6.5000 ----------=---------------------------'-------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . Additional desc.. .. Permit Fee . . . . Issue Date . . . . Expiration Date . . Qty Unit Charge 1943.00 .0350 576.00 .0200 LQPERMIT ELEC-NEW RESIDENTIAL 94.53 Plan Check Fee . Valuation . 3/05/06 Per BASE FEE ELEC NEW RES - 1 OR 2 FAMILY ELEC GARAGE OR NON-RESIDENTIAL 5.91 0 Extension 15.00 68.01. 11.52 Application Number . . . . . 05-00003889 Permit . . . PLUMBING Additional desc . Permit Fee 152.25 Plan Check Fee 8.95 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/05/06 Qty Unit Charge Per• Extension BASE FEE 15.00 14.00 6.0000 EA PLB FIXTURE 84.00 " 1.00 15.0000 EA PLB BUILDING SEWER 15.'00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5-. 3.75 1.00 15.0000 ---------=------------------------------------------------------------------ EA PLB GAS METER 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 3/05/06 Qty Unit Charge Per Extension BASE FEE" 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - LOT 97, PLAN 4520B, 1943 SF/ 255 SF CASITA,BOX BAY @ MBR -26 SF 4' GARAGE EXT - 88 SF.PERMIT DOES NOT INCLUDE BLOCK WALLS,POOL, SPA OR DRIVEWAY APPROACH. 75% REDUCTION TO PLAN CHECK FEES DUE TO MULTIPLE ISSUANCE OF SAME PLAN TYPE ------------------------------ Other Fees . . .. . . ----------------------------------"------------ . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES .. 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 14.43 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 _ DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI)'- RES 17.06 DIF STREET MAINT FAC -RES 15.00 LQPERMIT Application Number . . . . . 05-00003889 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . DIF TRANSPORTATION - RES 1098.00 Fee summary Charged ---------- Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total 1220.28 .00 .00 1220.28 Plan Check Total 163.57 .00 .00 163.57 Other Fee Total 2436.49 .00 .00 2436.49 Grand Total 3820.34 .00 00 3820.34 I LQPERMIT MAR 07,2006 10:57 BCI*TESTING,ri1 000-000-00000 Page 3 Ca10ERTS Certified Rating March, 7.2006 This Compliance rating is for the home located at: 81566 Ulrich Drive La Quinta C -A, 97.15:3 Certificate Number: CC3-1798358281 Date Inspected: March, 1 2006 Ca10ERTS Rater: William Henson Number of Stories: CC2004076 ` HERS Analyst: N/A Builder/ Developer: Shea Homes, Tnc. ,{ Project: Trilogy @ La Quinta I Phase: Phase 13A Plan Name: 4520 Lot Number: 097 Specifics about this home: General Inforrnation Conditioned•Floor Area: 1650 Square Feet Conditioned Volume: 0 Cubic Feet Front Orientation: N/A Number of Stories: 1 Heating and Cooling Systems U Value Heating Equipment; Furnace: 0.8 Cooling Equipment: AC. 12 f3uildinq Envelope Surface Area Pro osed Actual R Value U I Factor R I Value I U Factor Windows HVA(: Air Distribution Proposed Actual Orientation Area SHGC U Value SHGC U Value HVA(: Air Distribution Duct Location: Attic Duct Leakage Target: 6.0 Duct Insulation R -Value: 6 sated Duct in Conditioned Space: Teated Air Infiltrdtion Approved As Part Of Sample Group Blower Door Target: 96 Water Heatin S stem Pro osed TY I Size I Fuel I EF Distribution Water Ileatin System Actual TY I Size Fuel I EF Distribution Testing RcKufhs Main system HVAC system ested Dud Leakage: Yes Passed ested TXV: Yes - Passed ested Dud Design Compliance: N/A sated Duct in Conditioned Space: N/A ested Reduced Duct Surface Area: N/A ested Infiltration Reduction Credit: N/A BCI Testing 77-760 Country Club Drive, Suite I Palm Desert. CA. 92211 760-772-2951 Certifying Si„auture Date The energy efficrQmy rating of this hume is determined using California Horne Energy Rating System (C HERS) rules. The rating considers heating, cooling and water heatrny and assurnes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features, listed have been verified and approved by the CaICERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: C:alcERTS - Customer service 11 Natoma St Suite 140, Folsom, CA 9Srr-30. MAR 07,2006 10:57 BCI*TESTING,ri1 000-000-00000 Page 5 CaICERTS Certified Rating Marcli, 7 2006 This Compliance rating is for the home located at: 81566 Ulrich Drive La Quinta CA, 92253 Certificate Number: CC3-1798358885 Date Inspected: March, 1 2006 CaICERT5 Rater: William Henson Number of Stories: CC2004076 HERS Analyst: N/A Builder/ Developer! Shea Homes, Inc. ,� Project: 5 Trilogy @ La Quinta Phase: Phase 13A Plan Name: Casita Lot Nurpber: 097 Specifics about this home: General Information Conditioned Floor Area: 400 Square Feet Conditioned Volume: 0 Cubic Feet Front Orientation: N/A Number of Stories: 1 Heating and Cooling Systems Area Heating Equipment: Furnace: 0.8 Cooling Equipment: AC: 12 HVAC Air Distribution Duct Location: Duct Leakage Target: Duct Insulation R -Value: Air Infiltration Slower Door Target: Suildina Envelope Surface Area Proposed Actual R Value U I Factor R Value U Factor Windows Attie 6.0 6 Tested 48 L__J Approved As Part Of Sampla Group Water Heating System Pro osed TY I. Size I Fuel EF I Distribution Water Heating System Actual TY I Size Fuel I EF Distribution Testing Results Main System HVAC System Proposed, Actual ested TXV: V ested Duct Design Compliance: U Orientation Area ested Reduced Duct Surface Area: N/A SHGC Value SHGC Value Attie 6.0 6 Tested 48 L__J Approved As Part Of Sampla Group Water Heating System Pro osed TY I. Size I Fuel EF I Distribution Water Heating System Actual TY I Size Fuel I EF Distribution Testing Results Main System HVAC System ested Duct Leakage: Yes - Passed ested TXV: Yes - Passed ested Duct Design Compliance: N/A ested Duct In Conditioned Space: N/A ested Reduced Duct Surface Area: N/A ested Infiltration Reduction Credit: N/A BCI Testing 77.760 Country Club Drive, Suite I Palm Desert, CA, 92211 760-772-2954 - '/4" -]� L/ Le Ce i0if). L.: Data The energy efficiency rating of this home is determined using California Home Energy Rating System (C ITERS) rules. Tire rating considers lreatrrng, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the Features listed have been verified and approved by the Ca[CERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may cuutact: CaIURi'S - Customer Service 11 Natoma St Suite 140, Folsom, CA 95630. 03/02/2006 16:55 FAX PARAGONPSCHIMIO (a007/007 INSULATION CERTIFICATE This Is to'certify that insulation has been installed in conformance with the current energy regulation, Callfornia Administrative Code, Title 24, State of California, in the building at 81-566 ULRICH DR, LOT 4097, PHASE 13A, LA QUINTA, CA CEILINGS: TYPE: BLOW MANUFACTURER: Cacoon Stable THICKNESS: R-38 WALLS: TYPE: BATTS MANUFACTURER: Cacoon Borate THICKNESS: W-13 GENERAL CONTRACTOR: SHEA HOMES LICENSE # BY: TITLE: PARAGO SCHMID BUILDING PRODUCTS A MASCO Company LICENSE # 221517 BY: ' A (BU TITLE: ACCOUNT REPRESENTIVE DATE: a JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 � I I_ EM INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA IBC F-] Title 24 Other: Client: Sub -Contractor: Shea La Quinta, LLC DCCCC General Contractor: Architect: Structural Engineer: Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi Slump (inches): Supplier: Superior Time Sampled: G �� �� Mix Design: D83625P Time in Mixer (min.): Specified Strength (PSI): 4000 Water Added @ Jobsite (gals.): �1 Addmixture: POZZ 322N Concrete Temperature (F): Truck M t�S-- Ticket #: 3% -] Ambient Air Temperature (F): - .j� Field ID Marking: Set A - 4 cylinders T Weather: Unresolved Items: © None ❑ See Below Location of Sampler ❑ No Samples Taken Description of Work Inspected: Phase Lot# qoProduct Plan y S.�ICa 8 —O 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1), Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional rebar placed as per these details and as noted on £ , { n (n -„ ��� r n Also, typical details 2, 3/SD-1 and Notes on SN -1 apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were securely tied and supported off the earth. Accepted for concrete placement. ... .- c) 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx b , A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes. \— �' 1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx Verified correct mix design. I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jack C. Millin ICC Certificatio, No: 0842216-80 .. t C, . INK. (��\\}} Contrac or's Repre entativ Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page Oft JCM Inspections 39725.Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS. Phone: 760-345-5554 - Fax: 760-772-3895 I N S P E C TI O N S COMPRESSION STRENGTH TEST RESULTS Client: Shea La Quinta, LLC Date: 3112106 Project: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 81-260 Avenue 62 La Quinta, CA 92274 Set ID Structure Age of Test Compression Strength JCM ID Location Date Cast Cylinder ID (days) (psi) Set A Phase 13A - Lot # 4097 Slab on Grade 11-3-05 Concrete 273-623 Bedroom 2 Required psi: 4000 1749 7- 3380 1750 28 4780 1751 28 4730 CERTIFIED: JCM Inspections supplies the service of compression strength test results only. Per ASTMC39 Page 1 of 1 Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page I of I JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: Q✓ IBC 81-260 Avenue 62 La Quinta, CA Title 24 Client: Sub -Contractor: Shea La Quinta, LLC Sun Coast Tensioning Other: General Contractor: Architect: Structural Engineer: Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi Weather: Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons Sung �. Unresolved Items: Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips R None S L4,),, psi to 33.04 kips/33,000 lbs See Below Calibration Date: Machine # Phase X Lot# 1_I 0 ey-7 Product PlanL4 Description of Work Inspected: Actual Elongation (in) Specified Complies within 7% +/- of specified elongation. Lot # Location Tendons Elongation (in) Reference 11 h/SN2. --{ Yes No ri'2r'� -Z. � if`„ -tn t F���1f� `'� ['��`t�� r1.9M � � I ❑y ❑ �q' ©- ❑ LEl 'YIN/- 0- ❑ GD' ❑ A 4_3 I Ti 2- ❑ 0- ❑ ❑ ❑ ❑ ❑ ❑ ❑ I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jack CI -Millin ICC Certificatio No: 2216-89 Con epresentative: , Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page I of I