Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-3883 (SFD)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: , 05-00003883 1 Property Address: 81612 ULRICH DR APN: 764-270-999-94 -300234- Application description: DWELLING - SINGLE FAMILY Property Zoning: MEDIUM HIGH DENSITY RES Application valuation: 166943 t Tit!t. 4 4 " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: SHEA LA QUINTA C/O JEFF MCQUEEN DETACHED 8800_N GAINEY CENTER 350 SCOTTSDALE, AZ 85258 Applicant: /Architect or Engineer: �\� ' o QLc Cc 2la�v l -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: 672285 /Date: Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to,file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1' 1 I,_as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.I. Lender's Name: Lender's Address: LQPERMIT Contractor: SHEA HOMES, INC. 81260 AVENUE 62 LA QUINTA, CA 92253- (760)777-6005 ' Lic. No.: 672285 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/02/05 It nr.T 14 200511 ------------------- WORKER'S COMPENSATION DECLARATION ,1 hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. `have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: _ Carrier AMERICAN HOME ' Policy Number 1247619 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become sub u to the workers' compensation laws of California, and agree that, if I sh uld come subject o the the compensation provisions of Section 00 of the Labor C 1 s all"forthwi comply with those provisions. 4t:plicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS FUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL'FINES UP TO ONE HU RED THOUSAND DOLLARS (5100,0001 IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Ouima, its officers, agents and employees for any act or omission related to the work being, performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and stat4roftinspecon e above information is correct. I agree to comply with all city and c unty ordi antes and state laws relatinand hereb�authorize representatives of this cohu ty o an er upon n ate lawsbove-mentioneurposes. e: i nature (Applicant or A Application Number. . . . . . 05-00003883 Structure Information Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . .DWELLG/LODGING/CONG <=10 ' Flood Zone . . . . . NON -AO FLOOD ZONE Other struct info CODE EDITION 2001 CBC FIRE SPRINKLERS NO GARAGE SQ FTG 539.00 PATIO SQ FTG 537.00 NUMBER OF UNITS- 1.00 ---------------------------------------------------------------------------= 1ST FLOOR SQUARE FOOTAGE 1847.00 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee 856.50 Plan Check Fee 556.73 Issue Date . . . . Valuation• 161587 Expiration Date 3/01/06 Qty Unit Charge Per Extension BASE FEE 639.50 62.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 217.00 Permit MECHANICAL Additional desc.. Permit Fee 77.00 Plan Check Fee 21.63 Issue Date Valuation . . . . 0 Expiration Date 3/01/06 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 .00 11.0000 EA MECH FURNACE >100K .00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 .00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU .00 3.00 6.5000 EA MECH.VENT FAN. 19.50 1.00 6.5000 ------------------------------------ EA MECH EXHAUST HOOD L--------------------------------------- 6.50 Permit ELEC-NEW RESIDENTIAL .Additional desc . . Permit Fee . . . . 81.19 Plan Check Fee'. 3.76 Issue Date . . . . Valuation . . . . 0 , Expiration Date 3/01/0.6 Qty Unit Charge Per Extension .. BASE FEE 15.00 LQPERMIT Application Number 05-00003883 Permit . . . . . . ELEC-NEW RESIDENTIAL Qty Unit Charge Per Extension 1847.00 .0300 ELEC NEW RES - MULTI FAMILY 55.41 539.00 .0200 ---------------------------------------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 10.78 Permit . . .. PLUMBING Additional desc . Permit Fee . . . . 120.00 Plan Check Fee 16.50 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/01/06 Qty Unit Charge Per Extension BASE FEE 15.00 10.00 6.0000 EA PLB FIXTURE 60.00 1.00 .15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 6.00 .7500 EA PLB GAS PIPE >=5 4.50 1.00 15.0000 ---------------------------------------------------------------------------- EA PLB GAS METER 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/01/06 Qty Unit Charge Per Extension - BASE FEE 15.00 -------------------------------------------------- -------------------------- Special Notes and Comments SFD LOT 94 PLAN 5505A, INCLUDES 26 SF BOX BAYQ MBR, 83 SF GARAGE EXT, 315 SF PATIO EXT. 1821 S.F. PERMIT DOES NOT INCLUDE BLOCK WALL, POOL, SPA OR DRIVEWAY APPROACH. ------------------------------=--------------- Other Fees . . . . . ------------------------------ . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 - DIF CIVIC CENTER -'RES 366.00 ENERGY REVIEW FEE 55.67 DIF FIRE -PROTECTION -RES 97.00. GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 LQPERMIT _ Application Number . . . . . 05-00003883 ----------------------- Other Fees . . . ---------------------------------------------------- . . . ." STRONG MOTION (SMI) - RES 16.15 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited Due ----------------- Permit Fee Total ---------- 1149.69 ------------------------------ .00 .00 1149.69 Plan Check Total 598.62 .00 .00 598.62 Other Fee Total 2476.82 .00 .00 2476.82 Grand Total 4225.13 .00 .00 4225.13 LQPERMIT ' FEB 24,2006 12:53 BCI*TESTING,ril 000-000-00000 Page 4 CaICERTS Certified Rating February, 24 2006 This Compliance rating is for the home located at: 81612 Ulrich Drive La Quinta CA, 92253 Certificate Number: CC3-1798358278 Tested Duct Leakage: Date Inspected: February, 18 2006 I CaICERTS Rater: William Henson ested Duct in Conditioned Space: N/A CC2004076 C HERS Analyst: N/A ` E guilder/ Developer! Shea Homes,Inc. Project: Trilogy 0 La Quinta Phase: Phase 13A Plan Name: 5505 •S� Lot Number: 094 Specifics about this home: General Information Conditioned Floor Area: 2100 Square Feet Conditioned Volume: 0 Cubic Feet Front Orientation: N/A Number of Stories: 1 Heating and Cooling Systems Heating Equipment: Furnace: 0.8 Cooling Equipment: AC: 12 HVAC Air Distribution Duct Location: Attic Duct Leakage Target: 6.0 Duct Insulation R -Value: 6 Air Infiltration Blower Door Target: 120 Water Heating System Pro osed TY I Size I.. Fuel EF Distribution Water Heating S stem Actual TY I Size Fuel I EF Distribution Testina Results Main S Stem HVAC System Area Tested Duct Leakage: Yes - Passed Tested TXV: Yes - Passed Tested Duct Design Compliance; N/A ested Duct in Conditioned Space: N/A ested Reduced Duct Surface Area: N/A ested Infiltration Reduction Credit: N/A Buildinq Envelo e Surface Area Pro osed Actual R Value U Factor R Value U Factor Windows F7X TESTED ' (PAGE 1 OF 1) ©APPROVED AS PART OF SAMPLE CROUP FIRM: BCI TESTING ADDRES 77-760 COUNTRY CLUB DRIVE, SUITE I PALM DESSERT, CA 02211 PHONE: 760-772-2654 CERTIFYING SIGNATURE DATE The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verified and approved by the C8ICERTS Certified Rater shown above. If you have a concern o► complalnt regarding this report of the services used in obtaining it, you may contact; CaICERTS - Customer Service 11 Natoma St Suite 140, Folsom, CA 96630. Pro osed Actual Orientation Area rsHGC u u Value SHGG Value F7X TESTED ' (PAGE 1 OF 1) ©APPROVED AS PART OF SAMPLE CROUP FIRM: BCI TESTING ADDRES 77-760 COUNTRY CLUB DRIVE, SUITE I PALM DESSERT, CA 02211 PHONE: 760-772-2654 CERTIFYING SIGNATURE DATE The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verified and approved by the C8ICERTS Certified Rater shown above. If you have a concern o► complalnt regarding this report of the services used in obtaining it, you may contact; CaICERTS - Customer Service 11 Natoma St Suite 140, Folsom, CA 96630. JCM Inspections 39725 Garand Lane Suite F 'Palm DesertCA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA OIBC E] Title 24 Other: Client: Sub -Contractor: Shea La Quinta, LLC DCCCC General Contractor: Architect: Structural Engineer: Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi Slump (inches): ,.j"Zj Supplier: Superior Time Sampled: n `)N 7 0 Mix Design: D83625P Time in Mixer (min.): U Specified Strength (PSI): 4000 Water Added @ Jobsite (gals.): Addmixture: POZZ 322N Concrete Temperature (F): 1, Truck #: Zac- - Ticket #: 3(y 0 Ambient Air Temperature (F): 1 Field ID Marking: Set A - 4 cylinders Weather: Unresolved Items: gNone ❑ See Below Location of Sample: ,V00 n�.c — �4? C o n"Y1 ❑ No Samples Taken Description of Work Inspected: Phase 3 A Lot# Product Plan j'5CISA 1'0 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1), Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional rebar placed as per thesedetailsand as noted on C �1ciirr Vie. tin Also, typical details 2, 3/SD-1 and Notes on SNA apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were securely tied and supported off the earth. Accepted for concrete placement. n - R_ �r-- 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes. 1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx Verified correct mix design. I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications applicable building laws. Final report issued at project completion. Inspector: Jack C.,Millin ICC Certi ati \rt, V 0842216-80 Contractol'�Re�entative: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page I of CERTIFIED: �S X-=- JCM Inspections supplies the service of compression strength test results only. Per ASTMC39 0 Page 1 of 1 JCM Inspections 39725 Garand Lane Suite F EhAL===� 2� L" Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS COMPRESSION STRENGTH TEST RESULTS Client: Shea La Quinta, LLC Date: 3/12/06 Project: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 81-260 Avenue 62 La Quinta, CA 92274 Set ID Structure Age of Test Compression Strength JCM ID Location Date Cast Cylinder ID (days) (psi) Set A Phase 13A - Lot # 4094 Slab on Grade 1048-05 Concrete 273.620 Bedroom 2 Required psi: 4000 1701 7 3670 1702 28 5020 1703 28 4960 CERTIFIED: �S X-=- JCM Inspections supplies the service of compression strength test results only. Per ASTMC39 0 Page 1 of 1 JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: _C1 / � Project Name: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA ❑✓ IBC F-] Title 24 Other: Client: Sub-Contractor: Shea La Quinta, LLC Sun Coast Tensioning General Contractor: Architect: Structural Engineer: Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi Size and Type of Tendons: 1/2" Diameter Seven Strand Stress-Relieved Tendons Jack Machine Calibration: Received Sheet from Sun Coast-Gage Pressure in psi to Machine Load in kips 14r" psi to 33.04 kips/33,000 lbs Calibration Date: Machine Phase Lot# Oq Product 9,Plan, e., Weather: Ovecc a -, Unresolved Items: ❑ None ❑ See Below Description of Work Inspected: Actual Elongation (in) Specified Complies within 7% +/- of specified elongation. Lot # Location Tendons Elongation (in) Reference 11 h/SN2. -� nc Yes No /^ C. 'soca a. - S \ r J ' ©� ❑ ©- ❑ o-- ❑ , �� r-- �n C• .� 34 ElEl �^�a �S t ea \ `nn 3 4.;�-A q U 1 3.1 9 ❑ s('rr Qn, w,�-tL,�,� i +a,-r� 0 y 4 L' P-*' El,. , . —S, A-0- 1 y 9-- ❑ C6, r rin ©- ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jack C. Millin tt.ICC C��`e///rttificcatioon�No: `0842216-89 r Ox , , V l//`Y\\V./�_ .f_ � Contractor's/ R'eepprrersentative: �/ \-„i Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page of o