Loading...
07-3171 (AR)P.O. BOX 1504 ^' VOICE (760) 777-7012 78-495. CALLE TAMPICO FAX (760) 777-7011 LA QUINTA; CALIFORNIA 92253 BUILDING-& SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 ' BUILDING PERMIT Date: 7/23/08 Application Number: 07-00003171 Owner: Property Address: 51104 AVENIDA VALLEJO SALAS VICTOR M APN: 773-063-005-18 -000000- 51104 AVENIDA VALLEJO Application description: ADDITION - RESIDENTIAL LA QUINTA, CA 92253 Property Zoning: COVE RESIDENTIAL ~. (760)564-0236 'Application valuation: 120000 A Contractor: US 12 Applicant: Architect or Engineer: Owner CITyoF F/NAC QU1NTq E DFpr ' Lic. No.: NO LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code,.and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: License No.: NO for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.- Date: ssued-Date: Contractor: _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor _ Code, for the performance of the work for which this permit is issued. My workers' compensation , OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for -the Carrier 2001/2005 Policy Number following reason (Sec. 7031'.5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the,work for which this permit is issued, 1 shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State _� and agree that, if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or - 3700 of the Labor Code, I shall forthwith comply with those provisions. that he or she is exempt therefrom and the'basis for the alleged exemption. Any violation of Section 7031.5 by ����1111 % ` 2 any applicant for a permit subjects the applicant to a civil penalty of not,more than five hundred dollars ($500).: Date:.? pplicant: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and i the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND •• and who does the work himself or herself- through his or her own employees, provided thatthe- DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN - improvements are not intended or offered for sale. If, however, the building or improvement is sold within- SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.l. APPLICANT ACKNOWLEDGEMENT 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. - property who builds or improves thereon, and.who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_) I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City _ of La Quinta, its officers, agents and employees for any act or omission related to the work being ' -f► i:� ff performed under or following issuance of this permit. Date: 0 V Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced within180days from date of issuance of such permit,.or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit mcancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that 1 have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentionedprop ty for inspection purposes. Lender's Name: s� p Date: " Obignature (Applicant or Afm Lender's Address: LQPER IIT Application Number . . . . . 07-00003171_ Permit BUILDING PERMIT Additional desc Permit.Fee 709.50 P1an'Check Fee 461.18 Issue Date Valuation 120000 Expiration Date 1/19/09 Qty Unit Charge Per Extension BASE FEE 6,39.50 20.00 3.5000 ---------------------------------------------------------------------- THOU BLDG 100,001-500,000 70.00 Permit . . ELECT - ADD/ALT/REM Additional desc . Permit Fee 51.46 Plan Check Fee 12.87'' Issue Date Valuation 0 Expiration Date 1/19/09 Qty Unit Charge Per Extension BASE FEE, 15.00 ,1036.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 36.26 . 10.00 .0200 ELEC•GARAGE OR NON-RESIDENTIAL .20 Permit GRADING -PERMIT Additional desc . Permit Fee 15.00 Plan Check.Fee .00 Issue Date . . . . Valuation 0 Expiration Date 1/19/09 Qty Unit Charge Per Extension BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit. Fee 79.00 Plan Check Fee 19.75 Issue Date Valuation 0 Expiration Date 1/19%09 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 11.0000 EA MECH FURNACE >100K 22.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD_ 9.00 2.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 33.00 Permit PLUMBING LQPERM[T - Application Number . . 07-00003171 Permit . . . PLUMBING Additional desc . Permit Fee 91.50 Plan Check Fee 22.88" Issue.Date . . . . Valuation . . . . 0 Expiration Date 1/19/09 . Qty Unit Charge Per. Extension BASE FEE 15.00 11.00" 6.0000 EA PLB.FIXTURE 66.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50. 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ------------------------------------------------------------------------- Special Notes and Comments 1036 SQ. FT. ADDITION AND INTERIOR REMODEL APPROVED BY JAY WUU 'IN PLANNING ' DEPT. TOTAL SQ: FT. OF NEW -DWELLING WILL BE 1969 SQ, FT." Other Fees . . . . . . . . . ENERGY.REVIEW FEE 46.12 STRONG MOTION (SMI) - RES 12.00 Fee summary Charged Paid Credited Due -----------------------------------"----------- Permit Fee Total, 946.46 •.00 ..00, --------- 946:.4:6. Plan Check Total 516.68 .00 .00 516.68 Other Fee Total 58.12 .00 00 58.12 Grand Total' 1521.26 .00 .00 1521.26 LQPERMIT . Bin #.. /J//•��{ City of La Quinta, Building U Safety Division t :. �.- " •;� " P.O. Box 1504, 78-495 Calle Tampico 4 La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # ' �, 01 A Project Address: �� L Owner's Name: C TOP,CL I- q. A: P. Number: 7 -7 3 Address: Legal Description: ' - `. Ci ST Zi ` ty,' P: � Contractor: . ' Telephone: Address: . u1 Project Description: A - v City, ST, Zip:. Telephone: State Lic. # : , City Lic. #: p► )Arch.,.Engr., Designer:.A ot^— Address: Y., t7L jf 0 . IM City, ST, Zip: G-Af_ + `/ Telephone: 6 o 6 el '!?',-'7 <` '" Construction Type: Occupancy: State Lic. #: �� Project type (circle one): New Add'n Alter Repair.' Demo Name of Contact Person: S � t)V Sq. Ft.: Stories: ( • # Units: Telephone # of Contact Person: Estimated Value of Project: '�2 O �D�• O C7- .. APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd ' ' TRACKING. PERMIT FEES Plan Sets Plan.Check submitted Item 'Amount Structural Calcs. Reviewed, ready for, corrections • Plan Check Deposit a' Truss Calcs. Called Contact Person Plan Check Bal e ' Energy Cales. Plans picked up 1 (, �Constructio A Flood plain_ plan Plans resubmitted Mechani 1 M.tj I� Grading. plan 2" Review, ready tcorrect' • s/issue Electric TNd . ��,� Plumbing Subcontactor List' Called Contact Person OS Grant Deed Plans picked up S.M.I. H.O.A. Approval 1 f -Plans resubmitted Grading to IN HOUSE:-., ''" Review, readfor co r ns/issue 6 y �j ' Developer Im act F 1 Planning Approval. Called Contact Person A:I.P.P. Pub. Wks. Appr Date of permit issue'." School Fees _ at Total Permit Fees SET �ZISO `20 o'1yv-6C dil 0L_/ CERTIFICATE -OF COMPLIANCE Desert Sands Unified School District. z4�co 47950 Dune Palms Road . - ¢ BERMUDA DUNES r _ En RANCHO MIRAGE Cf" Date 7/23/08 La Quinta, CA 92253 t-, INDIAN WELLS - �i PALM DESERT y No. 30137 (760) 771-8515 v> LA QUOTA • � INDI� . . Q O' y Owner Salas APN # 773-063-005 Address Jurisdiction. La Quinta City Zip, Permit# Tract # ' No. of Units 1` ' Type Single Family Residence r ` Y - Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 51104 Avenida Vallejo_ 1036 Unit 6 Unit 2 Unit 7 Unit 3` Unit 8 Unit 4 Unit 9,' Unit 5 Unit.10 ' Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes: It has been determined that the above-namod owner is exempt from paying school fees at this time due to the following reason: 'EXEMPTION NOT APPLICABLE This certifies that school facility feesimposed pursuant to Education Code Section 11.620 and Government. Code 65995 Et Seq. in the amount of $2.97 X 1;036 S.F. or $3,076.92 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Bank of America - Victor Salas `, Check No.. 420441217, Name on the check Telephone '275.6691 Y • ' . it •. % Funding Residential, ..._ , yea t.Dtta¢p •. By Dr. Sharon R McGehee Superintendent •�' '��'`�"y� ' Fee collected /exemp d by M6�020(d)(I), y. Payment Recd � $ I C,5 .$3,076:92 er/URder JY < Signature . NOTICE: Pursuant to Government Cois rve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal - Emb6ssed•Original -Building Department Applicant Copy -Applicant/Receipt Copy - Accounting • P.O. BOX 1504 BUILDING & SAFETY DEPARTMENT 78=495 CALLS TAMPICO (760) 777-3012 LA QUINTA, CALIFORNIA 92253 FAX (760) ;777-701 1 To: Greg Butler, Building & Safety Manager To CDD: December 20, 2007 From: Doug Evans, Director -CDD Due Date: January.4, 2008 P/C #: '07-3171 Status: 1St Review', a Building Plans Approval (This,is an approval to issue a Building Permit) The Community Development Department has reviewed the Building Plans for' the following project' 'Description: Addition to Existing Non -conforming Residence Address or General Location: 51-104 Avenida Vallejo Applicant Contact- Victor Salas (760) 564-0236 The.Community Development Department finds that- ❑ ...these • Building Plans do not require Community Development Department approval. ❑ ...these Building Plans are approved by the Community Development Department. " :these Building Plans, require correctio s. Please forward a copy of the attached corrections to the applicant. hen the corrections , are made please return „ them to the Commu ty Development Department for . revi'�ew.Y ` , Date P.O. Boz 1504 3 •^ - • ` - LA QU[NTA, CAL[FORNIA,92247-1504'- BUILDING &SAFETY DEPARTMENT OFT19� , 78-495 C,ALLE TAMPICO , (760) 777-7012 LA.QUINTA, CALIFORNIA 92253 FAX (760) 777-70.11 July 20, 2009 Mr. Victor Salas 51104 Avenida Vallejo La Quinta, CA 92253 RE:, Building.Permit Extension Request.— 51104 Avenida Vallejo. Dear Mr. Salas: I have reviewed your letter received July 20; 2009, requesting 'a time extension for the construction of the. residential remodel and addition at the above address !' under Building Permit #07-3171. Our records indicate the following status on this permit. Inspection status: r Permit issued:. 08/1.2/08 ..Last successful inspection: 01/20/09 ' (footings/slab) 180 -day expiration date: 07/20/09 180-day.extension date: .01%18/10; Under the provisions of 2001 California Building, Code Section 106.4.4, your request is hereby granted. Because the Building Code specifies that "no permit shall be extended more than once, please be advised that unless the project passes its next required inspection on or before Monday, January 18, 2010, your building permit will expire automatically: Yours truly, ate►. • . • Greg Butler' Building &•Safety Manager" , Booz o z -inr l u Cal 0 0 r TELEPHONE (760)777-7012 FAX (760) 777-7011 OWNER/BUILDER INFORMATION Dear Property Owner: An application for a building permit has been submitted in your name, listing yourself as the builder of the property . improvements specified. e For your protection you should be aware that as "Owner/Builder" you are the responsible party of record on such a permit. Building permits are'not required to be signed by property owners unless they are personally performing their own work. If your work is being',performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her. name. Contractors are required by law to be licensed and 'bonded by the State of California and to have "a business license from the City or County. They are also required by law to put their license number on all permits for which they apply. I, If you plan to do your own work, with the exception of various trades that you plan- to subcontract, you should be aware of the following information for your benefit and. protection. If you employ or otherwise engage any persons other than your immediate family, • and the work (including materials and other costs) is $200.00•or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. If you are an employer, you must register with the State and Federal Government as an employer and you are subject to several_pbligations include. State and .Federal income tax wiithholding, federal social securi-ty_taxes,,workeli-_r's__ compensation insurance, disability insurance costs and unemployment compensation contributions. There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. • II For more specific information about your obligations under Federal Law, contact the Internal Revenue Service (and, if, you wish, the U.S. Small Business Administration). For more specific information about your obligations under'State Law, contact the.Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform,their work personally or through their; own employees, without a licensed contractor or subcontractor, only under limited conditions. r .I A frequent practice of unlicensed persons professing to be contractors is to secure an "Owner/Builder" building permit, erroneously,implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed" by property• owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board in;your community or at 1020 N. Street, Sacramento, California 95814. Please complete and return the enclosed owner -builder verification form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. " Very truly yours, I CITY OF LA QUINTA , DEPT. OF BUILDING AND SAFETY 78-495 Calle Tampico; La Quinta, CA 92253 (760) 777-7012 FAX: (760) 777-7011,. OWNER'S SIGNATURE/DATE V &Lps-10 PROPERTY ADDRESS n7 PERMIT NUMBER(S) . 1 fl r . TITLE 24 REPORT Title 24 Report for Vector Salas Addition 51-104 Avenida. Vallejo La Quinta, CA 92253GITY OF 1A DEPT' bU%LpING ®� �® PSP ops UCT►w FOR Project Designer: Dual Designs 760-641-4770 ' 4 Report Prepared By: Gina Rose EQS, Inc. 42-280 Beacon Hill #D-3 Palm Desert, CA 92211 (760) 674-2345 Job Number: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.2. by Energysoft Job Number: User Number: 5862 AL F� � � Certificate Of Compliance : Residential (Part,1 of 4) CF -1 R Addition Project Title 4/15/2008 Date 51-104 Avenida Vallejo I Quinta Project Address Building g Permit # F0S, Inc_ (760) 674-2345 Documentation Author Telephone Plan Check/Date FneravPrp Complii-6 ce Method 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtujsf-yr) Design Design Margin Space Heating 35.95 36.79 -0.84 Space Cooling 76.37 75.26 1.11 Fans 11.00 11.30 -0.30 Domestic Hot Water 31.74 28.70 - 3.04 Pumps 0.00 0.00 0.00 Totals 155.06 152.06 3.01 Building Type: W Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition [y� Existing + Add/Alt (S)180 deg. Propane Area: 238 ft2 Avg. U: Ratio: 12.1% Avg. SHGC: BUILDING ZONE INFORMATION Zone Name Floor Area F=oisting House 933 Addition 1 036 1.04 0.62 1.9% Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: # of Thermostat Volume Units Zone Type Type ?,_...___464 -0 4.7 Conditioned Setback R 99 _0_5,3_ Conditioned Setback OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Ronf Wnnd 433 n 04R R_21 R_n n 0_Q Wall 309 _0 09,15 -B_15_ R-0 0 0_ 9-0 noor None 13 0 500 None R-0 0 _Q _90 r)onr NnnP 1R n rinn NnnP R-0 n n q() Wall Wnod 40 n 095 R-15 R-0 0 90_90 Wall Wood 221 0095 R-15 R_0 0 _9090 Mau Wood 166 0 095 R-11; R -n n 1 R A nnnr Nnnp 1R x_500_ NnnP R_n 0 1R0 go noor None 20 0 500 None R-0 0 180 _9Q Wall Wnnd 76 _0095 R-15 R-0.0 180 9.0 Wall Wnnd 188 0095 R_15 R -n n 270 _9Q Rnnf Wood 1 n36n36 _n n9A R -3R R-0 n o_ o Wall Wood 17R 0 069 R-21 R-0.0 _0_9-0 Wall Wood got-00.fi9_ -H21 R-0 0_ A0 An Wall Wood 235 0 069 R_21 R-0.0 180 90 Wall Wood 2R 0069_ R-21 R -n 0 999i AD Door Mone 2n n 5nn Nnna R_n n 99.1; AD Wall Wood 6n f) p69 _B -21-R=00-27.0_0 1,969 ft2 933 ft2 0 ft2 1,969 ft2 8.0 ft 1.00 1 Vent Hgt. Area 2 n/a 2 n/a Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:3 of 16 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Vector Salas Addition 4/15/2008 Project Title Date FENESTRATION SURFACES True Cond. # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Location/ Comments 1 Window Rear (N) 16.0 12$.p NFRC X67 NFRC 0.90_ Fxosfinq Single Metal Tinted nefault Fxisting 2 Window Rear (N) 16.0 1.280 NFRC 0_67 NFRC 0 90 Existing Single Metal Tinted Default Existing 3 Window Right (E) 7.5 1.280 NFRC 0_67 NFRC 90 90 Existing Single Metal Tinted Default Existing 4 Window Right (E) 25.0 1.280 NFRC 0_67 NFRC 90 90 RemovedSingle Metal Tinted Default Existing 5 Window Right (E) 4.0 1.280 NFRC 0_67 NFRC 90 90 RemovedSingle Metal Tinted Default Existing 6 Window Right (E) 4.0 1.280 NFRC 0_67 NFRC 90 90 RemovedSingle Metal Tinted Default Existing .L 8 Window Window Right Front (E) (S) m_0- 1_280 NFRC -0-67 NFRC -90 90 RemovedSinole Metal Tinted Default 12.0 1.280 NFRC 0.67 NFRC 180 90 Existing Single Metal Tinted Default Existing Existing .9-- AQ 11 Window Left (W) 30.0 1.280 NFRC 0.67 NFRC 270 90 Existing Single Metal Tinted Default Window Left -W_ 30_0 1-2$0_NFRQ -M NFRC _270 M Existing Single Metal Tinted Default Window Rear (N) 20.0 0.870 NFRC 0_59 NFRC 0 90 New Double Metal Tinted Default Existing Existing Addition 12 Window Rear (N) 5.0 0.870 NFRC 0.59 NFRC 0 90 New Double Metal Tinted Default Addition. -Ja Window Rear (N) 5.0 0.870 NFRC 0"59 NFRC 0 -9.Q New Double Metal Tinted Default Addition 14 Window Right (E) 20.0 0.870 NFRC 0_59 NFRC 90 90 New Double Metal Tinted Default Addition 15 Window Right (E) 40.0 0.870 NFRC 0_59 NFRC 90 90 New Double Metal Tinted Default Addition 16 Window Right (E) 3.0 0.550 NFRC 0645 NFRC 90 90 New Glass Block Addition 17 Window Front (S) 16.0 0.870 NFRC 0659 NFRC: 180 90 New Double Metal Tinted Default Addition 18 Window Front (S) 5.0 0.870 NFRC 0_59 NFRC 180 90 New Double Metal Tinted Default Addition 19 Window Left (W) 12.0 550NFRC-QA5 NFRC _270 -3D-New Glass Block Addition 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Buq Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 92 None No Insulation 26-A1 Existing Existing Slab Perimeter 95 None No Insulation 26-A1 New Addition Run Initiation Time: 04/15/08 13:50:02 Run Code: 1208292602 EnergyPro 4.2 by Energysoft User Number: 5862 Job Number: Page:4 of 16 Certificate. Of. Compliance :,Residential (Part3 of 4) .. CF -1 R Vector Salas Addition Project Title Duct ti Date 4/15/2008, HVAC SYSTEMS Location Heating Type Minimum Eff Cooling Type Minimum Eff Condition Thermostat Status Type. Existing House _ Electric 0.80 HSPF Split Air Conditioner 14.0 SEER Altered Setback pre -altered for above Electric 0.80 HSPF Split Air Conditioner 10.0 SEER - Setback Addition Electric tl 0.80 HSPF Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT ' This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author' Name: Title/Firm: Dual Designs Address: Telephone: 760-641-4770 Lic. #: Ae (sig ture) at EnforcemenAgency Name: Title/Firm: Address: Telephone: Name: Gina Rose Title/Firm: EQS.Inc. Address: 42-280 Beacon Hill #D-3 Palm DesertCA 92211 Telephone: (760) 674-2345 signature) (date) I EneravPro 4.2 by EnerovSoft User Number: 5862 Job Number: Pape:5 of 16 1 Duct Duct Condition Ducts Location Heating Cooling Location •R -Value Status Tested? . Existing House Ducted Ducted Attic 4.2 New Yes Addition Ducted Ducted Attic 4.2 New Yes Hydronic Piping . Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS, Rated Tank Energy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status. or RE 1 (%) Ext. New 75 Gal. HWH Large Elec. No Pipe Insulation 1 75,000 74 Altered 0.76 0.00%- 0.0 Standard 50 gal or Less Existing - Small Elec, pre -altered for Aboy 1 40 000 50 0.48 n/a 1 n/a Multi -Family Central Water Heating Details Hot Water Pump. Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried .. Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT ' This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author' Name: Title/Firm: Dual Designs Address: Telephone: 760-641-4770 Lic. #: Ae (sig ture) at EnforcemenAgency Name: Title/Firm: Address: Telephone: Name: Gina Rose Title/Firm: EQS.Inc. Address: 42-280 Beacon Hill #D-3 Palm DesertCA 92211 Telephone: (760) 674-2345 signature) (date) I EneravPro 4.2 by EnerovSoft User Number: 5862 Job Number: Pape:5 of 16 1 Certificate Of Compliance : Residential (Part 4 of 4) CFA R Vector Salas Addition 4/15/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and "special verification to be used with the performance approach. The local enforcement aaencv determines the adeauacv of the iustification. and may reiect a buildina or desian that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The Roof "R-38 Roof (R.38.2x14.16)" includes credit for a. Radiant Barrier installed per Section 3.3.3 of the Residential Manual. The Existing Water Heater "Standard 50 gal or Less Existing" has an EF less than the Table R3-11 CEC Default Vintage Values. The Existing Electric Heat "Existing Unit' has an HSPF less than the Table R3-11 CEC Default Vintage Values. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF4R Plan Field installation certificate. The HVAC System "Existing House " incorporates HER_ S verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "Addition" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. Run Initiation Time: 04115/08 C • 12 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:6 of 16 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Check or initial applicable boxes or check NA if not applicable and included with the DESCRIPTION ENFORCE - permit application documentation. N/A DESIGNER ' MENT Building. Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ,. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). f§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ N' ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ;. ❑ b. -outside air intake with damper and control; flue damper and control El ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑El § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑X ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ El Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑ " ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain certification. ❑ ❑ ❑ Coefficient (SHGC), and infiltration 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.' ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures' § 110-13: HVAC equipment, water heaters, shIowerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance.with ASHRAE, SMACNA or ACCA. ❑- ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑, ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ u ❑X ❑ length of recirculating sections of. hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ' ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.2 by,EnergySoft User Number: 5862 Job Number: Page:7 of 16 Mandatory .Measures Summary:. Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑x❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be. used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ E ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑ ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ x❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ K❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section f'19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ x❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:8 of 16 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Vector Salas Addition 4/15/2008 SYSTEM NAME FLOOR AREA Existing House 933 Number of Systems 1 Heating System Output per System 62,000 Total Output (Btuh) 62,000 Output (Btuh/sgft) 66.5 Cooling System Output per System 48,000 Total Output (Bt uh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sqft) 51.4 Total Output (sgfUTon) 233.2 Air System CFM per System 0 Airflow, (cfm) Airflow, (cfm/sqft) Airflow (cfm/Ton) d400.O Outside Air (%) 72.5/46.7 of Outside Air (cfm/sgft) values above given at ARI conditions 0.0 of 63.7 of 63.7 of Outside Air 115 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 0 0 0 669 24,912 at Time of Cooling 0 0.0/0.0OF 67.3/44.2 OF 67.3/44.2 OF 0 2,300 0 0 115 -8,870 -120 115 8,402 0 Supply Fan Cooling Coil 0 0 2,300 0 0 New 4 Ton 55,598 0 Total Adjusted System Output 55,598 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK i Jan 12 am 105.0 of Supply Fan Heating Coil 1600 cfm 37 913 62,000 62,000 Jan 12 am Supply Air Ducts 103.6 of ROOMS 70.0 of 68.6 of <�: Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 0.0/0.0OF 67.3/44.2 OF 67.3/44.2 OF 55.0/37.6 OF .1 JWO Supply Air Ducts Outside Air 115 cfm Supply Fan Cooling Coil 55.5 / 37.9 of 1600 cfm ROOMS 6.1% R.H. 72.5/46.7 of 72.0 / 46.5 of Return AirDucts I EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page:9 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Vector Salas Addition 4/15/2008 SYSTEM NAME FLOOR AREA Addition 1,036 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I CFM I Sensible 477 8,624 800 494 18,386 0 894 1,697 0 0 115 -8,876 120 115 8,445 0 0 894 1,697 1537 680 New 4 Ton 55,613 0 Total Adjusted System Output 55,x13 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 62,000 62,000 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 0.0 OF 64.0 OF 64.0 OF 105.0 OF O Supply Air Ducts Outside Air 115 cfm 104.0 of Supply Fan Heating Coil 1600 cfm ROOMS 70.0 of 69.0 of I Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak . 0.0/0.0OF 67.3/44.2 OF 67.3/44.3 OF 55.0/37.6 OF OZh Supply Air Ducts Outside Air 115 cfm Supply Fan Cooling Coil 55.5 / 37.9 of 1600 cfm 6.1% R.H. ROOMS 72.5/46.7 of 72.0 ! 46.5 of Return Air Ducts I EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 10 of 16 ROOM LOAD SUMMARY ' PROJECT NAME Vector Salas Addition DATE 4/15/2008 SYSTEM NAME Existing House FLOOR AREA 933 - ROOM LOAD.SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Existing Existing 1 371 6,713 800 0 0 0 669 24,912 PAGE TOTAL I o 0 Oil 6691 24,912 TOTAL 1 0 0 0 669 24,912 EnergyPro By EnergySoft User Number: User Job Number: Page: 11 of 16 ROOM LOAD SUMMARY PROJECT NAME Vector Salas Addition DATE 4/15/2008 SYSTEM NAME Addition FLOOR AREA 1,036 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT, CFM SENSIBLE Addition Addition 1 477 8,624 800 477 8,624 800 494 18,386 PAGE TOTAL 1 477. 8,624 800 494 18,386 TOTAL 1 477 8,624 800 494 18,386 EnergyPro By EnergySoft User Number: User Job Number: Page:12 of 16 Project Title Date Vector Salas Addition 14/15/2008 Room Information Desicin Conditions Room Name Existing Time of Peak Jan 12 am Floor Area 933 Outdoor Dry Bulb Temperature o°F Indoor Dry Bulb Temperature 70°I Conduction Area U -Value AT °F Btu/hr Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. Page Total: 24 912 Infiltration: II i 1 .001 x 1.064 x 933 x 8.00 X 0.000 / 6] "X 70 = 00 chedule Air Sensible Area Ceiling Height ACH INT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 24,912. EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 13 of 16 933.0 X X X x x X X X X x x x X X x X X X X X. X X X X X X X X X X t X X X X X, X X X X, 0.0480 X X X , x X X X X X X= X XP70 X X " X X X X X X X X F X X x X X X X X X X X X X X X X X 70 = = = = = = = = = = = = = = = _ _ = = - - = _ = = = _ 3,135 309.0 0.0950 70 2,055 13.3 0.5000 70 466 17.7 0.5000 70 .620 16.0 1.2800 70 1.434 16.0 1.2800 70 1,434 40.5 0.0950 7b 269 7.5 1.2800 70 672 70 1,106 17.7 0.5000 620 20.0 0.5000 12.0 1.2800 1,075 188.0 0.0950 1,250 30.0 1.2800 70= 2,688 30.0 1.2800 70_2 688 perimeter = 92.0 ~0.7300 70' 4,701 , Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. Page Total: 24 912 Infiltration: II i 1 .001 x 1.064 x 933 x 8.00 X 0.000 / 6] "X 70 = 00 chedule Air Sensible Area Ceiling Height ACH INT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 24,912. EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 13 of 16 Project Title Date Vector Salas Addition 14/15/2008 Room Information Desicin Conditions Room Name Addition Time of Peak Jan 12 am Floor Area 1,036 Outdoor Dry Bulb Temperature ooF Indoor Dry.Bulb,Temperature 70 OF Conduction Area U -Value AT of Btu/hr Items shown with an asterisk(') denote conduction through an interior surface to another room. Page Total: 18 386 Infiltration: r 1.0o x 1.osa x 1 o3s x S.00 xF o.000 /601 x 70 = 0 schedule . Air Sensible Area . Ceiling Height ACH ILT Fraction TOTAL HOURLY, HEAT LOSS FOR ROOM 18,386 EnergyPro 4.2 by EnergySoftUser Number: 5862 Job Number: Page:14,of 16 1036.0 x x X X X X x X x X' X X X, X X X X x x X x x X X x X X X X x X. X X x X X x X X 0.0290 x x X X ` x X x X x X X x X x X X X x x x X X X X x x X X X x X X x X X x x x X ,70 = = = = = = = = = = = = = = - = _ = = - = = = = = _ 2,103 178.0 0.0690 70 860 20.0 0.8700 70 1,218 5.0 0.8700, 70 304 5.0 '0.8700 70. 304 201.0 0.0690 70 971 20.0 0.8700 70 1,218 40.0 0.8700 70 Z436 3a 0,5500. 70 116 235.0 0.0690 70 1,135 16.0 0.8700 70=974 5.0 0.8700 70 304 28.0 0.0690 70 135 20.0 0.5000 70= 700 0.0690. 70=qQn -12.0 0.5500 70 462 perimeter=950 07300. 70 4854 Items shown with an asterisk(') denote conduction through an interior surface to another room. Page Total: 18 386 Infiltration: r 1.0o x 1.osa x 1 o3s x S.00 xF o.000 /601 x 70 = 0 schedule . Air Sensible Area . Ceiling Height ACH ILT Fraction TOTAL HOURLY, HEAT LOSS FOR ROOM 18,386 EnergyPro 4.2 by EnergySoftUser Number: 5862 Job Number: Page:14,of 16 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Vector Salas Addition. 4/15/2008 Room Information Desi n Conditions Room Name: Existing Outdoor Dry Bulb Temperature: OOF Floor Area: 933 sf Outdoor Web Bulb Temperature: OoF Indoor Dry Bulb Temperature: 720 Outdoor Daily Range: 340F Opaque Surfaces R-21 Roof R-15 Wall Wood Door R-15 Wall R-15 Wall Wood Door Wood Door R-15 Wall Orientation Area X X X X X X X X X X X X U -Factor X X X X X X6.0 .X X X X x X CLTD 1 N 933.0 0.0480 37.0 N 309.0 0.0950 3.0 N 31.0 0.5000 3.0 E 40.5 0.0950 13.0 S 166.3 0.0950 6.0 S 17.7 0.5000 -7.4 (S) 20.0 , 0.5000 6.0 (W) 188.0 0.0950 13.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 13 Existing Window Existing Window Existing Window Existing Window Existin .Window Existing Window -7.4 0.0 -7.4 16.0 -7.4 0.0 -7.4 7.5 32.4 0.0 Orientation N N E S W • Page Total Shaded Area X x X X X x x X X X X GLF + + + + + + + + + + + Unshaded Area X X x x X X x X X X x Page GLF = = = = = = 0.0 -7.4 16.0 -7.4 0.0 -7.4 16.0 -7.4 0.0 -7.4 7.5 32.4 0.0 t -7.4 12.0 -3.4 0.0 -7.4 30.0 32.4 0.0 -7.4 30.0 32.4 Total Btu/hr 1,657 88 47 50 95 53 60 232 2 282 Btu/hr -118 -118 243 -40 972 972 1 911 - 4 Internal Gain Btu/hr Occu ants 4 X Occupants X 230 Btuh/oCC. = 920 E ui ment X Dwelling Units X 1 600 Watts/sqft = 1,600 Infiltration: 1 64 X 0.00 x �0 Air Sensible CFM ELA DT ITOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6.7131 Latent Gain Btu/hr Occu ants77777� F-41 X' Occupants x 200 Btuh/ocC. = 800 - Infiltration: 4 771. x 0.00 X 59.12 X 0.00000 = Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 800 EnergyPro 4.2 by EnergySoft User Number: 6862 Job Number: Page: 15 of 16 f� t RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Vector Salas Addition 4/15/2008 Room Information .. Desicin Conditions Room Name: Addition Outdoor Dry Bulb Temperature: 010 Floor Area: 1,036 sf Outdoor Web Bulb Temperature: 0oF Indoor Dry Bulb. Temperature: 72 OF Outdoor Daily Range:. 340F Opaque Surfaces R-38 Roof R.38.2x14.16 R-21 Wall .21.2x6.16 R-21 Wall W.21.24.16 R-21 Wall .21.24.16 R-21 Wall .21.24.16 Wood Door R-21 Wall (W.21.24.16) Orientation N N E S• SW SW (W). Area U -Factor 1,036.0 178.0 201.0 235.0 28.0 20.0 60.0 X 0.0201 x X 0.0690 X X 0.0690 X X 0.0690 X X 0.0690 X X 0.5000 X X' 0.0690 X X 17.2 X X E X X 20.OX x X 0.0X X x 52.2= X CLTD 1 37.0 3.0 13.0 6.0 11.0 11.0 13.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. .Nage I otal 1. Cooling Load Temperature Difference (CLTD) Fenestration 1 2 3 4 C 6 5 7 8 Orientation ,• Shaded Area X X X x X GLF F +; + + +x + Unshaded Area X X X X Page GLF = = = _ =. N 0.0 17.2 20.0 . 17.2 N 0.0 17.2 5.0 17.2 N 0.0 17.2 5.0 17.2 E 0.0x 17.2+ 20.OX 52.2= E 0.0X 17.2+ 40.0X 52.2= E 0.0x 23.5+ 3.0X 50.3= S 0.0x 17.2+ 16.0X 20.7= S 0.0x 17.2+ 5.0X 20.7= W 0.0x 23.5+ 12.0X 50. Total Btu/hr 770 37 180 97 21 110 54 1 269 Btu/hr Internal Gain Btu/hr Occupants 4 x Occupants X 230 Btuh/occ. = 920 E ui ment B1 X Dwelling Units x 1,6001 Watts/sgft 1 1,6001 Infiltration: 1.064 x oo x 65.64 X _ Air Sensible CFM ELA D7 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,624 Latent Gain Btu/hr Occu ants x 'Occupants tX 2001 Btuh/occ. = 800 Infiltration: 4 7t x 0.00 x 65.64 x 0.00000 = 1 Air Latent CFM ELA pW TOTAL HOURLY, LATENT, HEAT, GAIN FOR ROOM 800 EnergyPro 4.2 by EnergySoft User Number: 5862 Job Number: Page: 16 of 16