Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
9710-070 (SFD)
LICENSED CONTRACTOR DECLARATION U I hereby affirm under penalty of perjury that I am licensed under provisions of F- Chapter 9 (commencing with Section 7000) of Division 3 of the Business and 04LUProfessionals Code, and my License is in full force and effect. O =) M License # Lic. Class Exp. Date I LU oZ r— \,Date s Signature of Contractor � 0 J U C:) OWNER -BUILDER DECLARATION W d I hereby affirm under penalty of perjury that I am exempt from the Contractor's U) License Law for the following reason: Z_ ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) . I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). co () I am exempt under Section B&P.C. for this reason to N Date Signature of Owner ON O) Z WORKER'S COMPENSATION DECLARATION C:) 2 Z I hereby affirm under penalty of perjury one of the following declarations- U-) eclarations: r FZ O () 1 have and will maintain a certificate of consent to self -insure for workers' X W Y= compensation, as provided for by Section 3700 of the Labor Code, for the O � Q performance of the work for which this permit is issued. m Q U ( ) I have and will maintain workers' compensation insurance, as required by OU Q Section 3700 of the Labor Code, for the performance of the work for which this a 0 Z permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier rif t Policy No. r- d is� a` Yl Vrit i,v Q J (This section need not be completed if the permit valuation is for $100.00 or less). I certify that in the performance of the work for which this permit is issued, I ,shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of'the Labor /Code, I shall forthwith comply with those P11 I; j Date: � � [ � Applicant � , _ Y Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application, becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is • correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. Signature (Owner/Agent) «"F �� ' Date f t ��'• °� PERMITCONTROL# BUILDING PERMIT // D71i[-4�i4� S o /�� LOT TRACT O G . DATE VALUATION9ZA llklq I JOBSITEADDRESS �W W AVENIDA �° AL�.ti�JO APN 773-063-63 x OWNER CONTRACTOR/DESIGNER/ENGINEER JINC K L C°LAI. II,, C K f°:1..^,3;1 t'r;1",;' i. i, ("C)a; 5433.I0 r VEN10t1:H1 ft.id.ER-,i ici- 5i; Ai'[;3 14,,E EIFCK[ .i 9.A Q( jl ;TkA kYA LA QA JINWA { ,+L 4?? 4 USE OF PERMIT �al�k� �.k`L:t?l�tili iN%.'i.111).(:�+i i�lt•,iVt�'a A3�!) l�,f»iUE<iV tiY"k�C.i, t'LS 1afi1� +CYt� �.14V F�tAN PLAN' CHPM REM lCli ;f BY FOR, NIUl TITLE tS;jf;R c W SAA4I+, PL AN, �l ��1..eJ'7 )•i Al,'''S,p� S.:�'t�l !�Y d L�eU•!1 e 114" 1$c('t;i eA i K) 910'tlil 1A. �'iAR-Al''i1JOAi IA00X � 4i1 tkr SF C't:)N�if`t2ki`c"1'te��)+�i� iit�l�tH>fip4#l�t�t[t3i9 ��+al)��3ct 14 -A14{ 11414"K FV 7faj-ht})1�,4tti.,-alt; A SAT 100 10 ( _000_120- )[) a-(Y� '► VP F1, t`,e`iCS4�+";�1101v. v,.al,fa':-R;lIJO 11011 �00--'1414100 ttvk'RA,{3`�f&t.rc,"f`tfk9;1���: ���t3tN1��Ji-33b� �2,�111:+,z1. ClfitY'?1 f PLAN 1f1A fNlf)=.d:t1 . 1<5 V,; till NOV o 6 1997 y RECEIP'r ` ° "'DATE - BY/' DATE FINALED INSPECTOR Y: L,. Al INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck 7 Exhaust Fans O.K. to Wrap jrly F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final POOLS - SPAS BLOCKWALL APPROVALS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Water Piping Heater Final Plumbing Final Plumbing Top Out f I f Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fbdures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final 'Utility Notice (Perm) 74 :S..aY�,,!<'F:ti'r—�n•`�.:..,w;- .�;,�„,...rf_•y4,.;Frr.•`t.,,,�.^rI'd JS":.."'Y,•'..t.'-"`r..f�./'ryiY.r�,;..i.::j,'.krvy�.'�3�.:*`,,,-t.�:�yr:•�`y..�`;y,=,fes.+-,�1 t� 07D .4 u�l'ItrCu P.O. BOX 1504 APPLICATION ONLY Building 78-495 CALLE TAMPICO Address �� — 240VALL,.;'.1ti LA QUINTA, CALIFORNIA 92253 owner Mailing . rii Address c`i (j A �}0&YV lL✓CL City �. Zip Tel. 1 u'tittvt�L` �1 J5 `'� 'SLA l i Contractor C10.Y Address Zip j Tel.. State Lic. City & Classif. 13 5r7 L 6'] Lic. a Arch., Engr., Designer Address I Tel. City IZip I State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division/9 of the BBu�siin�esss�and7'Profe�ssions Code, and my license Is in full) ford'a and effect. 41,IL Lf:�t.I l.- j)�w . �P pl ! _/ SIGNATURE, I / DATE OWNER -BUILDER DECLARATION 1 hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5.Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for thealleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I.: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building orimprovement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I1 I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 17 1 am exempt under Sec. B. 8 P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company n Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed If the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ apy person in any manners as to become subject to the Workers' Compensation Laws of Calif ,q'a. Date Owners NOTICE TO rAPPLICANT: <lf,ialter making this Certi/icate o! Exemption you should become subject to the Workers' Compensation provisions o! the Labor'�Code, you must lorthwfth comply with such provisions or this permlf shall De deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of aQplicant Date Mailing Address City, State, Zip WHITE = FINANCE BUILDING: TYPE'CONST. OCC. GRP. A.P. Number 77-3 d / �n 3 oil' Legal Description LG( �2{ aL K 71 vL Q Project Description Sq. Ft. No. No. Dw. Size Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line'` Side Setback from Property Line FINAL DATE Issued by: INSPECTOR Date Validated by: OCTValidation: C ,lTy OF LA, 0`01 IN' YELLOW = APPLICANT PINK = BUILDING DIVISION i 1�. 1, ! ' Desert Sands Unified School District F Notice ; . .82-879 Highway 1141 . , • Indio, CA 92201 ., Document Cannot Be Duplicated' 619-775-3500 Y ' b CERTIFICATE OF COM_ PLIANCE Date 11/4/97 APN # 773-063''=011 ' No. 16229 Jurisdiction La Quinta Jack L. Clark Jr. > Owner Name Permit # No. 51240 .' Street . Avenida Vallejo Log # . _ City La Quinta zip' 92253 Study Area Tract # _ Lot #12 Square Footage 1478 Type of Development Single Family Residence 1 No. of Units 1 `Comments At the present time,+ the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures•or.replacement moliilehomes. It, has been determined the above-named owner is exempt from paying school.fees at this, time due to .the following reason: S: EXEMPTION NOT: APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.84 X 1;478 or $ 2,719.52 the property listed above and that building r permits and/or Certificates of Occupancy for this square footage in this proposed project may.;now, be issued, " t Fees Paid By cc/LaJolla Bank/Jack Clark ' �, , 3 Telephone -564 3511 , Name.on the check - �• . , By Dr. Doris Wilson,' Superintendent f ■ - Fee collected /exempted by Pauline Pearson ' Payment Received"."F�62;719.52 Check No. 301080 Signature x IOTICE: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you mayprotest the fees or other payment identified bove will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to I ollect them on the District('s)(s') behalf, whichever is earlier. Collector: Attach a copy of county or city plan check application form to dist rict:copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy,- Accounting ESCROW INSTRUCTIONS Cindy Burgin Escrow Officer paci'ic Co= ESCROW CoRpoRation 74920 HIGHWAY 111 INDIAN WELLS, CA. 92210 TELEPHONE (619) 568-0344 Escrow No. 17098 Date: August 14, 1997 This escrow company holds Department of Corporations Escrow License No. 963-0473'. CASH THROUGH ESCROW ................... ..........................$ 22,500.00 TOTALCONSIDERATION ...............................................$ 22,500.00 Buyer shall deliver to you any instruments.and/or funds required from Buyer to enable you to comply with these instructions, all of which you are authorized to use and/or deliver on or before 09/15/97, and when you are in a position to obtain a standard Policy of Title Insurance through CHICAGO TITLE INSURANCE COMPANY, provided that said policy has a liability of at least the amount of the above total consideration, covering the following described property in the City of La Quinta., County of Riverside, State of California: LOT 12 IN BLOCK 71 OF SANTA CARMELITA AT VALE LA QUINTA, UNIT NO.,9 AS SHOWN BY MAP ON FILE IN BOOK 18 PAGES 69 OF MAPS, RECORDS OF RIVERSIDE COUNTY, CALIFORNIA PROPERTY ADDRESS vacant lot 12,La Quinta,CA 92253 SHOWING TITLE VESTED IN: Jack Clark, a married man as his.sole and separate property FREE FROM ENCUMBRANCES EXCEPT: General and Special Taxes for current fiscal year, including any special levies, payments for which are included therein and collected therewith. Covenants, conditions, restrictions, reservations, easements,'rights of way, of record, if any; also exception or reservations of oil,gas or mineral rights, if any. .Bonds or assessments of record. 1). Buyer herein will pay All Cash for subject property and shall deposit into escrow prior to the close of escrow, the balance of total purchase price plus buyer's portion of. escrow and recording fees as required in the form of a Cashier's Check or Wire Transfer. 2). The parties herein agree that the closing of this escrow is subject to the Buyer's approval of Preliminary Title Report, CC&R's, if applicable within 3 days of receipt of same. Buyer's failure to notify Escrow Holder of any disapproval, in writing, within specified time limit, is deemed to be Buyer's approval of same and this contingency- eliminated. ontingencyeliminated. 3). Covenants, conditions; reservations (including exception of oil, gas, minerals, hydrocarbons, and/or lease without right of surface entry), restrictions, rights of way, and easements for public utilities, districts, water companies, alleys, and streets. 4). Buyer is aware and acknowledges and accepts and holds Seller harmless for said property.in regards to geological, flood hazard, seismic hazard and any special studies zones. Buyer has satisfied himself as to making any further inquiries at appropriate government agencies, lenders, insurance agents, or other appropriate entities concerning use of the Property under local building, zoning, fire health and safety codes as may be applicable under the Special Studies zone act, seismic Hazards mapping act, and local geological ordinance(s). 5). Buyer and Seller acknowledge that state laws prohibit this escrow from closing (recordation of Deed) until buyer's funds, including new loan proceeds, -have been collected; as defined by law. The undersigned Buyer (Borrower) understands that it is. their responsibility to determined from lender of their choice what type of funding instrument will be used. Also per diem interest will be charged to buyer and seller by their respective lenders while Pacific Coast Escrow Corporation determines that all funds required to close have been legally collected. It is.recommended that.Buyer have all funds wire transferred to close escrow without delay or additional interest expense. 6) . SPECIAL CLOSING INSTRUCTIONS AND RELEASE FROM BLANKET ENCUMBRANCE: od1�,g1�ter,��all ' J 'not close and funds. shall not be released from impound until t�,"�b�a ha been conveyed to the purchaser free and clear of -any blanket encumb aegiol s 7.). SPECIAL CANCELLATION INSTRUCTIONS FOR NON -DEFAULTING BUYER: If, through no fault of the Buyer herein, this escrow shall not clone year from'the date of the Agreement to .Purchase; (signed by bother Seller and Buyer),.Buyer shall have the right to the.return of all monies then deposited by him into escrow. Escrow holder is hereby authorized and instructed to refund said monies to Buyer.`. All: S&LLER(S) INITIAL. S) -INITIALS: MN AND ''r+ CONTRACTOR -�A6 - C����� - - ADDRESS s4 -350Ave. P,=g a OWNER JOB ADDRESS --SI-240 VALl-t.-)O This form shall be posted on the iob with the Building Insgaction Card at all times in a conspicuous place. It is the responsibility of the General Contractor or the Owner/Builder to monitor the sub -contractors that are on this list are the same persons performing the work. Any changes to this list must be approved the City of La Quints Department of Building & Safety Rda to work being "performed by a changed sub- contractor. Failure to comply will result in a stoppage of work and/or the voidance of building permit. MASONRY' PLUMBING d M. C�,I�i�n pluw+6ir, LATHING SUB -CONTRACTOR'S' TYPE OF 'STATE--- Q 4 3 WORKER'S QTY BUSINESS TRADE NAME LICENSE. CONTRACTOR'S' COMP: NAME/ LICENSE AWG 322309 -vl a1CAL INS eo of TA4W' NWeER:OIII FILE NUMBER/ ROOFING ECKLVtAD 1zooF►t4G NUMBER:`. METALr EXP. DATE GRADE/ d� A. FleruS Grpol�.Ig AIC -12 (p 10005 t(aq9 TI'M 7o -Q l4Z3,o►3 -117 EXCAVATE ^'� 1h�iv��'KJ INSULATION q a ► 3 SEWAGE DISP. PIPELINES PAINTING/ C-34 DECORATING CONCRETE/ [foe.}&-4ed C-8 owc - +Z46 �fwlG - 342463 Z 53 2 FOUNDATIONS LONL✓L+F, CO. ` a FENCING Jq GIAvIL Sr, LANDSCAPI A (FRiMINO B C-51 �.. MASONRY' PLUMBING d M. C�,I�i�n pluw+6ir, LATHING s A Ips} Ceviic DRYWALL Q 4 3 l PLASTERING C✓w • A `io►okK+- HVAC. Ca.l 1 VUL. ko app -DEN EAGa Cj1qq51 ELECTRIGsn� AWG 322309 -vl a1CAL INS eo of TA4W' I �t6i D 12. q, uJSD 07. q 10 ROOFING ECKLVtAD 1zooF►t4G tZ� METALr ExeNPT �,�� 97 NG r iM S� V%1AV r Irw Cott/ ► 3.I97 GLAZING1��,�r4 ^'� 1h�iv��'KJ INSULATION �v�lr;✓ IK�w�� �"t SEWAGE DISP. PAINTING/ -, ""` ano StiC K DECORATING TIS I p R P CABINETS/ vLE� A r,� A INSTALLATION FENCING Jq GIAvIL Sr, LANDSCAPI JO►Lk Cl kv� 34 C-29 3C 6 C-26 C-9 C-36 C-20 C-10 51S64') bO_ -1%3108 I b y= 40ap °113. C-39 '715643 ► C-43 C-15 S41S`1 ' C-17 C-2 35%.234 gl3o C-42 C-33 610 $y$ C-54 C-6 C-13 C-27 C-53 = WU1 oa�p 5oc�bb� S966VI 01 1 0 18 R7 3 i 131? i 3' lo►pEN814�J167 l wc32z.3oq-ot. ioL.DW CACUZ qwc. 47991,100 014 �47 app -DEN EAGa Cj1qq51 b7a X23198 AWG 322309 -vl INS eo of TA4W' I �t6i D 12. q, uJSD 07. q 10 tZ� ExeNPT �,�� 97 w rA4 ► 3.I97 AV I X89 t REP. WDEK 3517327 di/aa 10:!4 E,xftpT 131 a:,c2 M PT l I W3 0K WCrlificat&,o f FOccu arc e f ci, Y of -La. Quanta *� Buildin .and. Safe,t OF.epartment-' . �� �7�. - M This Certificate issued pursuant to the 'requirements of Section 109: of the Uniform Building Code, certifying that,, at -the time. of issuance, this structure was incompliance with the various ordinances of -the City regulating bui/ding construction or use. .For the following: BUILDING ADDRESS: 51`-240 AVENIDA ,VALLEJO Use Classification:' ~SINGLE' FAMILY DWELLING Bldg. Permit No. 9710-070. , Occupancy Group: R-3 Type of Construction:' VN Land ''Use Zone: RC Owner of Building: JACK L. CLARK JR.'' ,' •Address:. 54350�AVENIDA�HERRERA City:- LA QUINTA, CA., 92253 By: DANIEL P. CRAWFORD JR. Date: .3/11198 _ Building Official r. POST "IN,A CONS PIC,UOUS'PLACE_ " " ' Main Level WA-qA 2d ;2- Vo YAGHOUBI N ,I A, Construction is NOT PERMMFO on the following Code Holidays: New Year's Day D Martin Luther 1(ing Jr. Day Dr Z sident' s Day ��7ajv/ S j 60 /\,e, Meborial.DaY -independence Day C�4 4t Labor Day �5 CITY OF LA QUINTA, Veteran's Day .BUILDING & SAFETY DEPT. Thanksgiving Ray Christmas Day APPROVED FOR CONSTRUCT10t4. 'AN ADEQUATELY SIZED DEBRIS CONTAINER DAIS REQUIRED ON THE JOB SITE DURING ALL -0 PHASES OF CONSTRUCTION AND,MUST BE EMPTIED AS NECESSARY. FAILURE TO DO. SO MAY, CAUSE THE CITY TO HAVE THE CONTAINER DUMPED AT THE EXPENSE.OF THE OWNER/ CONTRACTOV • A RE -INSPECTION 'FEE OF $30 WILL BE CHARGED IF THE APPROVED PLANS AND JOB CARD ARE NOT ON CONSTRUCTION HOURS THE SITE FOR A SCHEDULED INSPECTION, NO D(CEPTIONS1 October 1st - April 30 Monday'- Friday: 7:00 a.m. to 5:30 P.M. Saturday: 8:00 a.m. to 5:00 P.m. Sunday: None Government Code Holidays: None May 1st - September 30th Monday - Friday: 6:00 am. to 7:00 p-EK4 Saturday: 8:00 a.mAo 5:00 pm Sunday: None 6/2/2008 Page: 32 Government Code Holidays: Nona Roof YAGHOUBI 1T�' O� LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION I DATE By _4- R9of• 6/2/2008 Page: 33 i Cii1�OFLA�U11'V 1 UILDING & SAFETY QEPT. AP'P'ROVED C4 FOR CONSTRUCTION i! 1 DATE BY i ? os 430A �� /9 c� x P y . goaF SSI �prrol rv6 :fes �� ►9 J3 -L 1 Nem �hsIAIA �a� 3 r K. T1s 3 8 ro R a`G - E� 2 ` ��tao�lg�Le� fo,h��% �1� �� 1 DESCRIPTION CKT'KT VOLTS AMPS - L .. r TOTAL UNI fPSVOLTS-AMPS DESCRIPTION CKT'KT VOLTS AMPS - L NO. OF �VPER UNITS TOTAL UNI fPSVOLTS-AMPS _ • 5 120 V. MULT OUTLET CKTS GEN L- @ 3 W PSF r 120 15 1.704 35,112 SM APPLIANCE CKTS 20 2' 00 120 1.5 ' .3,000 GRI CKTS 1201, 20 1 1_1_500 1,500 'SUBTOTAL _' 9,612.. _ 120 V. SGL OUTLET CKTS' DISPOSAL r . 20 ;. 2.400_ 2,40C DISHWASHER 120 20 =` ' 2,400 2.400 LAUNDRY 120 20 ` 1 2,400 .- 2,4C0 _ _ HOOD 120 3 ! 360 360 SUBTOTAL r7,560 FIRST 10.000 V-A a. 100% �— I 10.000 BAL V-A @ 40% I -�_ r 2.869 SUBTOTAL._ 12,869 RANGE _ 230 40 _ 9;200 9,200 AIC (LARGEST FAU OR A/C) 230 30 1 6,900 ' 6.900 TOTAL V-A ' 28,969 SELECT SERVICE SIZE TOTAL V-A 28,969 126.0 AMPS 230 VOLTS 230 --...__ USE 200 AIBP PANEL NOTE:: " H.E.R-S. `RATER FIELD VERIFICATION AND, DIAGNOSTIC DUCT TESTING REQUIRED. RESULTS ;OF+THE, DIAGNOSTIC TESTING MUST BE REPORTED ON A CF -6R FORM. ADDITIONALY, . , - FORM CF 4R MUST BE SUBMITTED TO THE CITY OF LA QUINTA PRIOR TO _. ISSUANCE• OF CERTIFICATE•:OF OCCUPANCY. . S I, • 7 r j + TITLE 24 REPORT Title 24'Report for: Yaghoubi Residence 51240 Avenida Vallejo La Quinta, CA Project Designer:- . t. Report Prepared.,By: Joan D. Hacker Insu-form, Inc. 41-921 Beacon Hill, Suite A ' Palm Desert, CA 92211 (760) 779-0657 . CITY OF LA QUINTA Job Number: BUILDING & SAFETY DEPT. D [ p a APPROVED, FORCONSTRUCTION JUL 2 4 2008 DAT BY Date: By. 7/23/2008. The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. 'This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 2655 +3 `k , , Certificate Of Compliance : Residential (Part 1 of 3) CF -1 R Yaahniihi Residence 1,400 ft2 Existing Floor Area: 7/23/2008 Date Project t Title I aSallinta ft2 Slab on Grade Area: .51940qvp-nidaValle;o Project Address ft2 Average Ceiling Height: 8.0 Building Permit # Inset-ft7rm, Inc 1.00 (760) 779-0657 1 Documentation Author Telephone PlanCheck/Date FeLgVPro Compliance Method (.A (;IimatP 7nnt= 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtulsf-yr) Design Design Margin Space Heating 2.19 1.92 0.27 Space Cooling 101.57 95.22 6.35 Fans 13.62 13.40 0.23 Domestic Hot water 16.20 16.20 0.00 Pumps 0.00 0.00 0.00 Totals 133.58 126.74 6.84 Percent better than Standard: 5.1% Building Type: [j] Single Family ❑ Addition ❑ Multi Family [X_1 Existing + Add/Alt Building Front Orientation: (S) 180 deg Fuel Type: Natural Gas Fenestration: Area: 186 ft2 Avg. U: 0.79 Ratio: 13.3% Avg. SHGC: 0.70 Total Conditioned Floor Area: 1,400 ft2 Existing Floor Area: 1,400 ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 1,400 ft2 Average Ceiling Height: 8.0 ft Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units 1 4nn 11 �gnn 1 nn Zone Type Type rlitinned Setback Hgt. Area 2 / I h ing 7nne OPAQUE SURFACES Insulation Act. Type Frame Area. U -Fac. Cay. Cont. Azm. Tilt Wall Wnnd 72 n 11n R-11 R -n n 1Rn _gn noor None 20 0 500 Mone R -n n 1R0 qQ Wall Wood 214 0110 R-11 R_0 n 270 _gn Wall Wnnd 41R n11n R_11 R -on 0 An ]Q/all Wnnd 68 n 11n R_11 R -n 0 _gp _ An Rnnf wood 1 4nn n 025 R-18 R_n n 180 n Gains Condition Y / N Status JA IV Reference Location / Comments ® ❑Fxisting MA2 Fxisting I iving ® ❑Existing 28-A4 Fxistinq I Mnq ® ❑Fxisti 09-A2 Fxisting Living ® ❑Fxisting n9 -A2 Fxisting I iving IN ❑Existing 09-A2 Fxisting Living ® ❑Altered n1-A1FR (F=W-A4 Fxisting iving I EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:3 of 9 1 ,Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R Yaghoubi Residence 7/23/2008 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NERC or Table 116B. INTERIOR AND EXTERIOR SHADING Windnw Front 0S1 200 n 7aoI16-A 07 116-R 1801 I0_ Fxistina Dniihip Metal Claar g Fxisting I ivin9 2 Window Left (W) 10.0 0.790 116-A 0_70 116-B 270 90 Existing Double Metal Clear Existing Living 5 Window Left (W) 16.0 0.790 116-A 0_70 116-B 270 90 Existing Double Metal Clear Existing Living 4 Window Rear (N) 40.0 0.790 116-A 0_70 116-B 0 90 Existing Double Metal Clear Existing Living 5 Window Rear (N) 12.0 0.790 116-A 0_70 116-B 0 90 Existing Double Metal Clear Existing Living 6 Window Rear ' (I) 30.0 0.790 116-A0 70 116-B 0 90 Existing Double Metal Clear Existing Living Z Window Right (E) 8.0 0_790 116-A 0_70 116-B 90 __Q Existing Double Metal Clear Fxistinq LMn 8 Window Right (E) 40.0 0.790 116-A 0.70 116-B 90 90 Existing Double Metal Clear Existing Living 6 Window Ri hc1_t (Fa 10.5 0.870 NERC 0_70 NERC 90 90 Existing Double Mtl Uncoated Default Existing Living 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NERC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 2.0 5.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 6"8 6.0 2.0 0.1 2.0 2.0 5 Buq Screen 0.76 2.0 6.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 6.0 5.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 2.0 4.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 .2.0 9 Bug Screen 0.76 3.5 3.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 90 None No Insulation 26-A1 Existing Existing Living Run Initiation Time: 07/23/08 09.15.37 Run Code: 1216829737 EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:4 of 9 tEMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of, Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation. quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Joan D. Hacker Title/Firm: Title/Firm: Insu-form, Inc. Address: Z Address: 41-921•Beacon Hill, Suite A Palm Desert, CA 92,211 Telephone: Lic: #: - Telep one: 760 779-0657 - A • o .. (signature) (date) (sig ur (date) Enforcement Agency Name: Title/Firm: - Address: Telephone: (signature) (date) 4.4 by EnerovSoft - User Number: 2655 . V Certificate Of Compliance : Residential (Part 3 of 3) CF -1 R Yaghoubi Residence 7/23/2008 Project Title Date HVAC SYSTEMS Heating Minimum.', Cooling : Minimum Condition Thermostat Location Type Eff Type Eff Status Type . Living Zone Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Altered Setback pre -altered for above .. Central Furnace 75% AFUE Split Air Conditioner 10.0 SEER Setback HVAC DISTRIBUTION ` - r Duct Duct Condition Ducts Location Heating ,: Cooling Location R -Value Status' Tested? Living Zone Ducted Ducted Attic 4.2 Altered No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank _ Energy Tank Insul. Water Heater # in Input Cap. , Condition Factor Standby., R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE < Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40;000 50 Existing 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried ' Insulation ' tEMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of, Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation. quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Joan D. Hacker Title/Firm: Title/Firm: Insu-form, Inc. Address: Z Address: 41-921•Beacon Hill, Suite A Palm Desert, CA 92,211 Telephone: Lic: #: - Telep one: 760 779-0657 - A • o .. (signature) (date) (sig ur (date) Enforcement Agency Name: Title/Firm: - Address: Telephone: (signature) (date) 4.4 by EnerovSoft - User Number: 2655 . Mandatory, Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the. Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is"incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. Building Envelope Measures *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. § 150(b): Loose fill insulation manufacturer's labeled R -Value: § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox b. outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed. § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include CF76R Form: § 116-17: Fenestration Products, Exterior Doors; and Infiltration/Exfiltration;Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. - 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. Space Conditioning, -Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. , § 150(i): Setback thermostat on all applicable heating and/or cooling systems. § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation .Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B.,'. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 4:4 by EnergySoft User Number: 2655 Job Number: El ❑ ❑ El ❑ ❑ ❑ ❑ ❑ ❑. ❑ ❑ ❑ ❑ El ❑ u N ❑ a ❑ a ❑ o ❑ N ❑ a ❑ ❑ ❑ a ❑ ❑ ' ❑ Page:6 of 9 ENFORCE - N/A DESIGNER MENT ❑ ❑ o ., . ❑ ❑ ❑ El 2 ❑ El ❑ ❑ El ❑ ❑ ❑ ❑ ❑ ❑. ❑ ❑ ❑ ❑ El ❑ u N ❑ a ❑ a ❑ o ❑ N ❑ a ❑ ❑ ❑ a ❑ ❑ ' ❑ Page:6 of 9 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not applicable. N/A DESIGNER ENFORCE - MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ § 150(m): Ducts and Fans and have an output frequency no less than 20 kHz. 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ a ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ that meets the applicable requirements of UL 181, UL 181A, or UL.181 B or aerosol sealant that meets the requirements § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms be high by dimmer OR ❑ 0 ❑ of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ tape shall be used. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ © ❑ 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). in the cross-sectional area of the ducts. Page:7 of 9 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ® ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ❑ ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ "' ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ . ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑, ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E241E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ® ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms be high by dimmer OR ❑ 0 ❑ shall efficacy luminaires (except closets less than 70 ft) OR are controlled a switch are controlled by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ © ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:7 of 9 PROJECT NAME DATE Ya houbi Residence 7/23/2008 SYSTEM NAME FLOOR AREA Living Zone 1,400 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 74,000 Total Output (Btuh) 74,000 Output (Btuh/sgft) 52.9 Cooling System Output per System 41,500 Total Output (Btuh) 41,500 Total Output (Tons) 3.5 Total Output (Btuh/sgft) 29.6 Total Output (sgft/Ton) 404.8 Air System CFM per System 1,395 Airflow (cfm) 1,395 Airflow (cfm/sgft) 1.00 Airflow (cfm/Ton) 403.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD HVAC EQUIPMENT SELE COIL COOLING PEAK 11COILHTG.PEAK CFM Sensible Latent 11CFM1 Sensible 1,345 20,076 1,874 398 19,527 0 4,035 2,797 0 0 0 0 0 0 0 0 0 4,0351 2,797 28,146F 187741 25 121 Carrier 3SETGO4230 28,896 9,412 74,000 Total Adjusted System Output 28 896 8,412 74,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pmt I Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0°F 68.1°F 68.1°F 118.0°F Supply Air Ducts Outside Air 0 cfm 116.1 OF Supply Fan Heating Coil 1395 cfm ROOMS 70.0 OF 68.1 OF I Return Air Ducts < DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6°F 80.7/67.0°F 80.7/67.0°F 61.3/60.1°F O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 64.0 / 61.1 OF 1395 cfm 53.9% R.H. ROOMS 78.0 / 66.1 OF 80.7/67.0 °F � >% Return Air Ducts 4 EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: Page:8.of 9 1 ROOM LOAD SUMMARY PROJECT NAME DATE Ya houbi Residence 7/23/2008 SYSTEM NAME FLOOR AREA Livinq Zone 1,400 EnergyPro 4.4 by EnergySoft User Number: M55 Job Number: Pagei9 of 9