Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2015-0093
r Contractor: SOLARCITY CORPORATION SOLARCITY CORPORATION F 3055 CLEARVIEW WAY � J ATTN ZOE STEELE SAN MATEO, CA 94402 SAN MATEO, CA 94402 (650)963-5630 Llc. No.: 888104 VOICE (760) 777-7125 78-495 CALLE TAMPICOD 14 FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 _ � COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 9/29/2015 Application Number: BSOL2015-0093 Owner: Property Address: 52165 AVENIDA VALLEJO CARLY JACQUES APN: 773222019 52165 AVENIDA VALLEJO Application Description: 7.68kW PV SYSTEM - (29) 265W PANELS/(1) INVERTER LA QUINTA, CA 92253 Property Zoning: Application Valuation: $16,983.85 Applicant: Contractor: SOLARCITY CORPORATION SOLARCITY CORPORATION 3055 CLEARVIEW WAY 3055 CLEARVIEW WAY ATTN ZOE STEELE ATTN ZOE STEELE SAN MATEO, CA 94402 SAN MATEO, CA 94402 (650)963-5630 Llc. No.: 888104 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 o"ne rofessions Code, and my License is in full'force and effect. License lass: C B C10 A,C20 Li seDate S � Contractor1 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from t e ontractor's State License Law for the following reason (Sec. 7031.5, Business and Pro essions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I ) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' A on, as provided for by Section 3700 of the Labor Code, for the performance for which this permit is issued.have and'will maintain workers' compensation insurance, as required by 0 of the Labor Code, for the performance of the work for which this permit y workers' compensation insurance carrier and policy number are: 6. Carrier:- Policy Number: _ _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to b me subjec the workers' compensation laws of California, and agree that, if I o d beco su ject to the workers qompensation provisions of Sectio 700 a abor C de, I shall forthwith comp thns. ' Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERG IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND Cl L NES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO TH ST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances ar constru tion, and hereby authorize representatives of t above; mentioned brpperty for inspection purposes. Date: Signature (Applicant or Agent � 1 FINANCIAL 1 • 1 t DESCRIPTION t ' I °.;fiA000UNT� ' QTY- tAMOUNT PAID,", it PAID DATE + e- BSAS SB1473 FEE 101-0000-20306. 0 $1.00 0- 0.00 ' METHOD 4 2..w RECEIPT # CHECK # ` CLTD BYv Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $0.00 a . -"�DESCRIP71ON x ..ACCOUNT 'r` =QTY 7A MOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 0A Pi41D'BY:, ' y 'METHOD'' RECEIPT;# CHECK # CLTD BY h . '.DESCRIPTION' = r ',-ACCOUNT'. QTY ° 'C= *` AMOUNT =Fa �� -PAID s - .PAID,DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 sPAID BY'' METHOD ;: , , RECEIP,T,#� CHECK # CLTD BY. Total Paid for ELECTRICAL: $48.34 $0.00 DESCRIPTION ."- } +? d�. 1.A000UNT r.' .."� ,QTY AMOUNT PAID 'PAID.DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID.BY.,.!: RECEIPT '� r''CHECK#'` .'CLTD BY. Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS: $141.19 00 Description: 7.68kW PV SYSTEM - (29) 265W PANELS/(1) INVERTER Type: SOLAR Subtype: Status: APPROVED Applied: 7/6/2015 EVA Approved: 9/28/2015 LUR Parcel No: 773222019 Site Address: 52165 AVENIDA VALLEJO LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 77 Lot: 8 Issued: UNIT 10 CHRONOLOGY TYPE' `STAFF NAME G Lot Sq Ft: 0 Building Sq Ft: 0_ Zoning: Finaled: Valuation: $16,983.85 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 E-MAIL Details: 7.68kW SOLAR ARRAY - (29) 265W KYOCERA PANELS (1) ABB# PVI-6000-OUTD-US-I-A-AFCI INVERTER [514SF] 2013 CALIFORNIA ELECTRICAL CODE. 7/20/2015 ARE READY TO BE PICKED UP FOR CORRECTIONS. 84.; Applied to Approved Printed: Tuesday, September 29, 2015 8:38:40 AM 1 of 3 CsrsTEMS ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE' `STAFF NAME G ,ACTION DATE5. � ','COMPLETION DATE. SENT ELENA AN EMAIL. 1ST REVISION IS COMPLETE PLANS E-MAIL LUIS URIBE 7/20/2015 7/20/2015 ARE READY TO BE PICKED UP FOR CORRECTIONS. E-MAIL LUIS URIBE 8/3/2015 8/3/2015 SENT ELENA AN EMAIL WITH CORRECTION ATTACHED. SENT ELENA AN EMAIL LETTING HER KNOW PERMIT IS READY E-MAIL LUIS URIBE 9/28/2015 9/28/2015 TO BE ISSUED. PLAN CHECK PICKED UP STEPHANIE KHATAMI 7/21/2015 7/21/2015 ELENA PLAN CHECK SUBMITTAL ED VASQUEZ 7/6/2015 RECEIVED PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 9/24/2015 9/24/2015 RECEIVED RESUBMITTAL AJ ORTEGA ' 9/17/2015. 9/17/2015_. PLANS RESUBMITTED BY SOLARCITY - ELENA LOYA PUT BACK ON LUIS DESK CANNOT FIND FOLDER CHECK WITH RESUBMITTAL PHILIP JUAREZ 7/24/2015 7/24/2015 PLANS EXAMINER. Printed: Tuesday, September 29, 2015 8:38:40 AM 1 of 3 CsrsTEMS INSPECTIONS PARENT PROJECTS REVIEWS � s' , _; � ., ,. _ , �, ._ :. , =•y, "RETURNED •� - �-' .�; ,l --7 :4.- :+ :REVIEW TYPE ,REVIEWER SENT DATE DUE DATE -: STATUS `t z� ..REMARKS NOTES' . i a Printed: Tuesday, September 29, 2015 8:38:40 AM 2 of 3 CRSYSTEMS CONDITIONS INFORMATION < DESCRIPTION `' , ACCOUNT -QTY ;{ AMOUNT PAID PAID DATE `RECEIPT # CHECK # METHOD' PAID BY" CONTACTS BY �. ''NAME TYPE`ADDRESSI $0.00 CITYI:; ' STATE'` ZI-'3 ,`.PHONE-. sem. FAX r � _ •EMAIL 101-0000-42403 0 $24.17 $0.00 APPLICANT SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 mplasse@solarcity.co PV SYSTEM - ARRAY, 101-0000-42600 0 M CONTRACTOR SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 FIRST 20 PC mplasse@solarcity.co - Total Paid for ELECTRICAL: $48.34 $0.00 m OWNER CARLY JACQUES 52165 AVENIDA LA QUINTA CA 92253 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS: VALLEJO INSPECTIONS PARENT PROJECTS REVIEWS � s' , _; � ., ,. _ , �, ._ :. , =•y, "RETURNED •� - �-' .�; ,l --7 :4.- :+ :REVIEW TYPE ,REVIEWER SENT DATE DUE DATE -: STATUS `t z� ..REMARKS NOTES' . i a Printed: Tuesday, September 29, 2015 8:38:40 AM 2 of 3 CRSYSTEMS FINANCIAL INFORMATION < DESCRIPTION `' , ACCOUNT -QTY ;{ AMOUNT PAID PAID DATE `RECEIPT # CHECK # METHOD' PAID BY" BY BSAS SB1473 FEE 101-0000-20306. 0 $1.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC - Total Paid for ELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS: INSPECTIONS PARENT PROJECTS REVIEWS � s' , _; � ., ,. _ , �, ._ :. , =•y, "RETURNED •� - �-' .�; ,l --7 :4.- :+ :REVIEW TYPE ,REVIEWER SENT DATE DUE DATE -: STATUS `t z� ..REMARKS NOTES' . i a Printed: Tuesday, September 29, 2015 8:38:40 AM 2 of 3 CRSYSTEMS NON-STRUCTURAL - LUIS URIBE 7/6/2015 7/13/2015 7/20/2015 REVISIONS REQUIRED 1 WK ` I NEED A CUT SHEET FROM THE INVERTER NON-STRUCTURAL - LUIS URIBE 7/24/2015 7/31/2015 8/3/2015 REVISIONS REQUIRED SHOWING THAT MORE THAN 2 STRINGS CAN BE 1 WK CONNECTED WITHOUT THE NEED OF EXTERNAL COMBINER FUSE. NON-STRUCTURAL - LUIS URIBE 9/17/2015 9/24/2015 9/28/2015 REVISIONS REQUIRED 1 WK NON-STRUCTURAL- LUIS URIBE 9/24/2015 10/1/2015 9/28/2015 APPROVED 1 WK Printed: Tuesday, September 29, 2015 8:38:40 AM 3of 3 CR SYSTEMS '4, i . f srrt. # city Of %a QUif to Buikbg 8r Safety Duron P.O. Box 1504, 78-495 Calle Tampico La.Quinta, CA 92253 -:(760) 777-7012 Building Permit Application' and Tracking Sheet Permit # ProjectAddress. Owner's Name:. A. P. Number Address:rJ Legal Description: City, ST, Zap: La Quints CA Contracto, Solar City Address: 3055 Clearview Way. Telephone Proje4Description: roof mmoun'ted"pa city, ST, zip: San Mateo; CA, 94402 inverter(s) Telephone: 650-638-1028 State Lia # : 888104 City Lic, ik Arai., EW-, Designer. Address: City,, ST, Zip: Telephone: State Lia #: Name of Contact Person: Elena Loya Construction Type: " Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq.Ft.: #Stories: #Units: Telephone # of contact Person: (442-)256-1134 Estimated value of Project APPLICANT: DO NOT WRITE BELOW THIS UNE is Submittal Req'd Reed TRACKING PERM[P FEES Plan Sets Plan Check submitted Item ' Amount Structural Calm Reviewed, ready for corrections 6/7 Plan Check Deposit. . Truss Calm Called Contact Person IMMA 1 L— IM Pian Check Balance. Tide 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted. " Mechanical Giadlag plan ' Review, ready for correctiouslissue Electrical Sabeontactor List Called Contact Person Plumbing Grant Deed Pians picked up S hLL H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''" Review; ready for correetionsAssae Developer Impact Fee Planning Approval Called Contact Person A.LP.P. Pub. R!ks. Appr Date of permit Issue, School Fees Total Permit Fees EXIS11NG-ELECTRICAL SERVICE ENTRANCE 125A 240V 10 1000A MAIN BREAKER 1 PV STRING,#1 13 MODULES KYOCERA #KU2656ZPA - PHOTOVOLTAIC SYSTEM UTILITY 3445 WATT (DC) DISCONNECT'SWITCH i 3095 WATT (AC) ' CUTLER -HAMMER #'DG222URB 60A, 240VAC I I 35A/2P V PV —� I 2 8 MODULES S#2� -- _-- I----------------------------------------- --—Eil ---------------------------------� 1F--15A/1P ___________________ KYOCERA 2 6ZP I� �_ r T, 1 _ -------- .------------- -- 2120 WATKDC65 A __ ( ) .... 1905 WATT (AC) 6000 WATT UTILITY INTERACTIVE INVERTER ------------------------- O (1) AWG #8, THWN-2, Black o (1) AWG #8, THWN72, Red O °D (2) AWG #10, PV Wire, 60OV, Black (1 ) AWG #10, Solid Bare Copper EGC 90 TO 600 VDC TO 120 /240 VAC 10 ---- � (1 AWG #10, THWN72, White NEUTRAL Vmp =240 VAC Imp= 28 AAC -` 3/4" EMT (1) Conduit. Kit; ....................................................... . POWER 1 ABB# PVI-6000-OUTD-S-US-Z-A i 2 PV STRING #2 . (4) AWG #10, PV Wire, 600V, Black (1) AWG #10, Solid Bare Copper EGC Voc* Vmp = 345.01 VDC Isc = 9.26 ADC =-248 VDC Imp= 8.55 ADC ` COMBINE STRINGS AT THE INVERTER i 8 MODULES _ KYOCERA #KU2656ZPA CONFIDENTIAL. - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE J B— r� r� 7 r� p JOB NUMBER C3 L L J L Q 00. O 2120 WATT (DC) DESCRIP110N: JACQUES RESIDENCE DESIGN: Chris Wachter 1905 WATT (AC) " MOUNTING SYSTEM: Comp Mount Type C BENEFIT OF ANYONE EXCEPT SOLARCITY INC., ' NOR SHALL IT BE DISCLOSED IN.WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS 52165 AVENIDA VALLEJO Z 7.685 KW PV ARRAY TO 120/240V — ;. IN CONNECTION WITH SINGLE PHASE _ LA QUINTA CA 9225) UTILITY SERVICE :: ORGANIZATION, EXCEPT THE SALE AND USE OF THE RESPECTIVE (29) KYOCERA # KU2656ZPA O (1) AWG #8, THWN-2, Black o (1) AWG #8, THWN72, Red O °D (2) AWG #10, PV Wire, 60OV, Black (1 ) AWG #10, Solid Bare Copper EGC Voc* .Vmp = 560.64 VDC Isc = 9.26 ADC = 403 VDC Imp= 8.55 ADC - DC -(1) (1 AWG #10, THWN72, White NEUTRAL Vmp =240 VAC Imp= 28 AAC -` 3/4" EMT (1) Conduit. Kit; ....................................................... . —(1) AWG #6, . THWN-2, Green ... EGC/GEC. - (1) Conduit. Kit; 3/4" EMT 2 ff . (4) AWG #10, PV Wire, 600V, Black (1) AWG #10, Solid Bare Copper EGC Voc* Vmp = 345.01 VDC Isc = 9.26 ADC =-248 VDC Imp= 8.55 ADC ` (1) Conduit. Kit; 3/ " EMT . ........................................................... CONFIDENTIAL. - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE J B— r� r� 7 r� p JOB NUMBER C3 L L J L Q 00. O PREMISE OWNER: JACQUES, CARLY DESCRIP110N: JACQUES RESIDENCE DESIGN: Chris Wachter " MOUNTING SYSTEM: Comp Mount Type C BENEFIT OF ANYONE EXCEPT SOLARCITY INC., ' NOR SHALL IT BE DISCLOSED IN.WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS 52165 AVENIDA VALLEJO Z 7.685 KW PV ARRAY r1Sola'rCiy® ;. IN CONNECTION WITH MODULES LA QUINTA CA 9225) :: ORGANIZATION, EXCEPT THE SALE AND USE OF THE RESPECTIVE (29) KYOCERA # KU2656ZPA - 3055 CleorvieN Way S3 Moteo, CA 94402 ; REV pph SOLARCITY EQUIPMENT. WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC 7606258705 PAGE NAME ONE LINE DIAGRAM PV 6 a 9/23/2015 T: (650) 638-1028 F: (650) 638-1029 (see)-soL-an (yes -24a9) .,.w.sdorcI►y. INVERTER ABB PVI-6000—ouTD—US—z—A GROUND SPECS . MAIN PANEL SPECS GENERAL NOTES IINVERTER SPECS MODULE SPECS LICENSE OND (N) #6 GEC TO (E) UFER AT PANEL Panel Number: NoLabel Inv 1: DC Ungrounded INV 1 - (1) ABB #Pte-6Zigbee TD -US -Z -A LABEL: A - (29) KpV K265W6 CA # 888104 WITH IRREVERSIBLE CRIMP Meter Number: 65809203 FCI Inverter; Zigbee 6000W, 240V, 96.5% Module; 238.1W PTC, 40MM, Blk Frm, H4, ZEP, 1000V, Blk Cell, o Backbar C-10 INV 2 Overhead Service Entrance Voc: 38.3 Vpmox: 31 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 125A CENTER -FED MAIN SERVICE PANEL E3 100A/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! Solarcity CUTLER -HAMMER Inverter 1 IND 4 A 1 100A/2P Disconnect 5 ABB A Dc+ VStart = 200V PVI-6000-OUTD-US-Z-A oc MP1:1x13 (E) LOADS B L, zaev--------- ------------ --�---- -- _19S -----------------� ZWC /1� L2 pC+ VStdl't = 200V 35A 2P GND CC " D 11 EGCI DC+ 3 MP2: 2x8 1 1 13)/ ---- ------------------------------------- A --- GEC DG I It GND EGC--------------+--------------J (1 )Conduit Kit; 3/4' EMT N I I EGCIGEC _ z z c� CITY OF LA QUINTA BUILDING & SAFETY DEPT. TO 120/240V 1 SINGLE PHASE UTILITY SERVICE i PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED APPROVED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE FOR CONSTRUCTION PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF 1 GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST DATE BY ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS CONDUCTOR SIZING IS CALCULATED IN ACCORDANCE WITH NEC 690.8(A)(1)-(4) & (B)(2)(B). Voc* = MAX VOC AT MIN TEMP POI (1) CUTLER-HAMAM7 BR235 PV BACKFEED BREAKER Breaker, 35A 2P, 2 Spaces B (1) CUTLER -HAMMER $ DG222URB /� Disconnect; 60A, 24OVac, Non -Fusible, NEMA 3R A (1) SolarCity # 4 STRING JUNCTION BOX D� 2x2 STRMGS, UNFUSED, GROUNDED /y - (1)MERp DG10ONB Ground Kit; 60-100A, General Duty (DG) - (6) Shoals STG.ILF.I5.MC4 Inline fuse holder, 15A. MC4, Unserviceable, Wtherproof -(2)Ground Rod; 5/8" x 8', Copper eutral and O� 1 FAWG #8, THWN-2, Black Ise (1)AWG #8, THWN-2, Red L (1 )AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=28 AAC (1)AWG /6, THWN-2, Black Voc* = 345.01 VDC O (1)AWG /6, THWN-2, Red Vmp = 248 VDC (1 AWG THHN/THWN-2,,Green, EGC, Isc = 18.52 ADC Imp= 17.1 ADC (2)AWG $10, PV Wire, 60OV, Black Voc* = 560.64VDC Isc = 9.26 ADC O (1)AWG #10, Solid Bare Copper EGC Vmp = 403 VDC Imp= 8.55 ADC 70 )AWG #6,. THWN-2,. Been , , EGC/GEC - (1) Conduit. Kit;. 3/47.EMT.......... ... _ . . /10, , , . , ,_ . , , , . , , , , (1 AWG #10, THWN-2, Black Voc* 560.64 VDC ® (1)AWG 110, THWN-2, Red Vmp = 403 VDC , , , _, , , , , Isc - 9.26 ADC Imp= 8.55 ADC . (4 )AWG X10, PV Wire, 600V, Black Voc* =345.01 VDC Isc = 9.26 ADC O (1)AWG #1p Solid Bare Copper EGC Vmp = 248 VDC Imp=.8.55 ADC . _ ... , . (1) AWG /10, THHN/THWN-2, , Geern.EGC .................................. ................................................................ CONFIDENTIAL - THE INFORMATION HEREIN NUMBER: JB -9223628 00 PREMISE OWNER: DESCMPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., JACQUES, CARLY JACQUES RESIDENCE Chas Wachter SolarCity. NTING SYSTEM: f �' NOR SHALL IT BE DISCLOSED IN WHOLE OR INomp Mount Type C [lNMTM. 52165 AVENIDA VALLEJO 7.685 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS LA QUINTA CA 92253 MODULES: 3055 aearvie. Way Son Mateo, CA 94402 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE 9) KYOCERA # KU2656ZPA r PERRMISSIONCITY EOFISOLARCITY OUT THE WRITTEN PAGE NAME 7606258705 THREE LINE DIAGRAM ' REV DATE PV 5 a 9/23/2015 T:(650) 638-1028 F:(650) 638-1029 (N8)-SOL-ClTY (765-2469) www.solarcity.aDrn BB PVI-6000-OUTD-US-Z-A = UPLIFT CALCULATIONS =► J r a 0,6.09.2015 ..� _ PV• System Structural l Version At 46.4 SolarCity -DeM a n 'SOftwa re •-. r Project Information`& Table Of Cdntents' _ Risk Category: DESIGN: - Chris Wachter �`' BENEFIT OF ANYONE EXCEPT SOLARCITY INC., - NOR SHALL IT, BE DISCLOSED IN WHOLE OR IN PART TO OUTSIDE THE. RECIPIENTS Pi System Type:_Sol ��•�� Solarcit`,® arc ity. SleekMountT" Comp Roof MODULES Comp Roof La ers ofCom —Roofn ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE 2�� - PAGE NAME Roof_Stope SHEET:- REV. •DATE 14° INVERTER: "ABB •PVI-6000-OUTD-US- Z -A Rafter S do PV 4 a 9/23/2015 24" O.C. PVVSSystem, Module Orientation PV Module Area Landscape and Portrait ; �i5 4 f PV Module Width 39" PVModule Length' b5" Standoff Attachment Hardware Comp Mount Type C Reduced Ground/ Roof Live/.Snow Loatls Ground Snow Load Pg— 4 ,0.0 psf ASCE Table. 7-1 SurroundingTRoof Snow._,.___„ _ 0:0_psf' ASCE Eq: 7.4-1 Roof Snow Over PV Modules - - - �"o.0 sf •• - — ASCE Eq: 7.4-1 t Wind Design Criteria Wind Design Code - : . - ASCE 7710 .. Wnd Design Method " ;Partially/Fully Endosed MethprJ~ Basic Wind Speed V 110 mph Fig. 26.5-1A ExposureCatego_ry _ C Section 26.7 Roof Style Gable Roof - Rg. 30.4-z�A/B/C_-SA/B Mean RoofHe%ght �h 15 ft Section 26:2 ` Effective Wind Area 1 Module A 17.7 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients - Wind Pressure. Exposure Kz - 0.85, Table 30.3-1 Topgra"^ Sectinophi 26.8 Wind Directionality Factor Kdr '0.85 Section 26.6=1 Iin orta Fact&�`I � NA - r i.. - Velocity Pressure - t _ 9h yh = 0.00256'(KZ) (�) (Kd) (V^2) 22.4 sf Equauoti 30.3-1 Ext. Pressure Coefficient.(Up)• Ext.: Pressure Coefficient Down rGcp (Up) -0.88 ' 0.45 Flg. 30.4-2A/B/C 5A/B Ag. 30.4 7A/B%6-SA/B GCpDown Design Wind Pressure P p gh GC •-I 'Equation 30.4-1 Wind Pressure Up �.— P_(!!P.)_ r — -19.6 psf Wind Pressure Down down 16.0 psf Allowable Standoff'Spacings - X -Direction Y. -Direction Max Allowable Standoff Spaing Landscape t; 72" 39" ' Max Allowable Cantilever =Lands a'p 24"NA, Standoff Conf uration • - Landscape Not -Staggered Max Standoff Tributn rea Trib.r,,, _, 1 PV Assembly Dead Load ` — " - W -PV 3 psf Net d—Uplift at Standoff '�T-actual -195 Ibs� Uplift Capacity of Standoff ' T -allow 500 lbs Standoff Demand Ca aci DCR 38.90/cO Max Allowable Standoff Spacing Max Allowable Cantilever Portrait 48" 65" Portrai'rt 20" NA Standoff.Confi uuration Portrait " Not -Staggered Max. Standoff_T6tgjpry Area PV Assembly Deed Lod Tdb 22 sf VV-Pv 3 psf ' NeiWind UpliR at Standoff _--_T-actual 1218 lbs. Uplift Capacity of Standoff T -allow 500 lbs Standoff Demand Ca ci DCR —43.6% CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE • JOB NUMBER c JB '9223628 00 PREMISE OYMER. - DESCRIPTION:• JACQUES, CARLY JACQUES- RESIDENCE DESIGN: - Chris Wachter �`' BENEFIT OF ANYONE EXCEPT SOLARCITY INC., - NOR SHALL IT, BE DISCLOSED IN WHOLE OR IN PART TO OUTSIDE THE. RECIPIENTS s 52165 AVENIDA VALLEJO 7.685 KW PV ,ARRAY ��•�� Solarcit`,® MOUNTING SYSTEM 'Comp -Mount Type C ' ' OTHERS MODULES LA QUINTA CA 92253 � ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (29)� KYOCERA # KU2656ZPA PAGE NAME ,055 aearvler way sm, Mateo, CA 94402. SHEET:- REV. •DATE SOLARCITY EOUIPMENT;'WITHOUT THE WRITTEN PERMIS90N of SOLARCITY INC. 1 INVERTER: "ABB •PVI-6000-OUTD-US- Z -A . . .. • 7606258705 r UPLIFT CALCULATIONS PV 4 a 9/23/2015 T:(650) 638-1026 ,F:(650) 638-1029 (8'88T)SOL-CITY(765-2466) www.solarcity.com PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (2-1/2" EMBED, MIN) (E) RAFTER A SIDE VIEW OF MP1 NTS MPI X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC PORTRAIT 48" 20" SEAL PILOT HOLE WITH POLYURETHANE SEALANT. TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI 270 PITCH 19 STORIES: 1 ARRAY AZI 270 PITCH 19 Comp Shingle CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR MALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. S1 STANDOFF JOB NUMBER JB -9223628 00 MOUNTING SYM COmD Mount Tvoe C KYOCERA # KU2656ZPA ABB # PVI-6000—OUTD—US—Z—A INSTALLATION ORDER Y -SPACING I Y -CANTILEVER NOTES (1) LOCATE RAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. (3) INSERT FLASHING. (4) PLACE MOUNT. (5) INSTALL LAG BOLT WITH SEALING WASHER. (6) INSTALL LEVELING FOOT WITH BOLT & WASHERS. PREMISE OWNER: JACQUES, CARLY 52165 AVENIDA VALLEJO LA QUINTA, CA 92253 7606258705 q 11'-5" (E) LBW B SIDE VIEW OF MP2 NTS 7� MP2 X -SPACING X -CANTILEVER Y -SPACING I Y -CANTILEVER NOTES LANDSCAPE 48" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI 90 PITCH 14 STORIES: 1 ARRAY AZI 90 PITCH 14 Comp Shingle JACQUES RESIDENCE 7.685 KW PV ARRAY PAGE NAME STRUCTURAL VIEWS Chris Wachter SHEET: REV.. DATE PV 3 0 9/23/2015 r;;SolarCity I'h� 3D55 Clearvlew Way Son Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com PITCH: 19 'ARRAY, PITCH: 19 MPI AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 14 ARRAY PITCH: 14 125A, 240V, SINGLE PHASE, MP2 AZIMUTH: 90 ARRAY AZIMUTH: 90 2 WIRES, 22kAiC MATERIAL: Comp Shingle STORY: 1 Story EXISTING BI DIRECTIONAL METER#65809203 U CITY OF LAI QULNTA., m 0 Inv r BUILDING &' SAFET µ, _pEPT " i �. APP F" �f� : t�# AOO�FO 3' FSB 3' FSB FOR CONSTRUC ION — — — — — ya ]TAG DATE I --BY _Ch - I I o B . - LEGEND • I o I 0 (E) UTILITY METER & WARNING -LABEL N o I� j lav INVERTER W/ INTEGRATED DC DISCO Z1 & WARNING LABELS Pitch y _ 3� FSB — © DC DISCONNECT &WARNING LABELS • 15/12 s, 3 Tw © AC DISCONNECT & WARNING LABELS Ln DC JUNCTION/COMBINER BOX & LABELS wl Front Of House D TRANSFORMERINFORMATION: A rnDISTRIBUTION PANEL &LABELS l D I I WI (E) DRIVEWAY Q KVA PHASE o HIGH KV I I I o LG LOAD CENTER & WARNING LABELS LOW 120/240V CD _ I O DEDICATED PV SYSTEM METER -METER#65809203 3' FSB L 3' FSB L — _ — — — o STANDOFF LOCATIONS "PROPOSED BI-DIRECTIONAL 3' FSB CONDUIT RUN ON EXTERIOR METER#____CONDUIT RUN ON INTERIOR CUTLER -HAMMER # DG222URBGATE/FENCE - AC DISCONNECT: s 0 HEAT PRODUCING VENTS ARE RED 0 FT FROM MAIN PANEL �_ INTERIOR EQUIPMENT IS DASHED C) - - INVERTER: ABB a SITE E PLAN " #DG222URB Scale: 1/8" = 1'w E 0 1' 8' 16' CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER JB -9223628 0 0 PREMISE OWNER. DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE JACQUES, CARLY JACQUES RESIDENCE Chris Wachter '\�;`SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �'� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type .0 52165 AVENIDA VALLEJO 7.685 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTSORGMODULES LA QUINTA, CA 92253 C Way THE �SALE nAND USE OF ON, EXCEPT ITHE RESPECTIVEN CONNECTION () # SHEET: REV DATE 29 KYOCERA KU2656ZPA 3055 MateCleao, CA 94402 440 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: — T: (650) 636-1028 F:(65638-1029 PERMISSION OF SOLARCITY INC. INVERTER: 7606258705 PV 2 a 9 23 2015 (888)—SOL—CITY (765-2489) www.solarcity.com ABB PVI-6000—OUTD-US—Z—A SITE PLAN / / A ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES ' T A AMPERE 1. THIS SYSTEM IS GRID—INTERIIED VIA A ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. ELECTRICAL, PLUMBING, ENERGY, AND GREEN CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING BUILDING CODES AND THE LA QUINTA MUNICIPAL DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN CODE EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING - EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, CITY OF LA QUINTA FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE BUILDING & SAFETY DEPT. } GALV GALVANIZED ART. HAZARDS.EACH GECGROUNDING ELECTRODE CONDUCTOR UNGROUNDEDR CONDUCTOR OF THE APPROVED GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE , IDENTIFIED BY FOR CONSTRUCTION HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL i Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). DATEBY Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER t kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE v SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. _ S STAINLESS STEEL V� STC STANDARD TESTING CONDITIONS l T ( TYP TYPICAL -- UPS UNINTERRUPTIBLE POWER SUPPLY (� V VOLT VICINITY MAP INDEX Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT i A 3R NEMA 3R, RAINTIGHT ` PV1 COVER SHEET -= PV2 SITE PLAN PV3 STRUCTURAL VIEWS _ PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES +•i _ PV6 ONE LINE DIAGRAM PV7 ELECTRICAL CALCULATIONS Cutsheets Attached CA888104 #CALIFORNIA C-10 1. ALL WORK TO BE DONE TO THE 2013 BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. REV BY DATE COMMENTS MODULE GROUNDING METHOD: ZEP SOLAR AHJ: La Quinta - REV A NAME DATE COMMENTS * * * * UTILITY: Imperial Irrigation District w a••`. �1I'� a '� a wa f�' � - � �,- * * * * CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THESolarCity. JOB NUMBER JB -9223628 0 0 PREMISE OWNER: DESCRIPTION: JACQUES, CARLY JACQUES RESIDENCE DESIGN: Chris Wachter �: •. MOUNTING SYSTEM: Comp Mount Type C BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 52165 AVENIDA VALLEJO 7.685 KW PV ARRAY /, PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH LA QUINTA CA 92253 C__ MODULES: 305 CIS`" "°r T: (850) Son Mateo, F:(650) 638-1029 THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN (29) KYOCERA # KU2656ZPA PAGE NAME SHS: REV: DATE INVERTER: PERMISSION of SOLARCITY INC ABB PVI-6000-OUTD-US-Z-A 7606258705 COVER SHEET PV 1 a 9/23/2015 (888) -SCI -CITY (765-2489) www.soIa°I{Y.�„ ELECTRICAL CALCULATIONS 1 � t TNG & SAFET`� � " •a = ► ;�1t Bv«opvFkOvrcD �g CONSTRUCTION 8Y - Module: 29 Kyocera 265W 1000V CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER JB -9223628 0 0 CONTAINED SHALL NOT BE USED FOR THE Voltage Drop Calculations Version 5_8.0 Vdrop = Im '* 2 * Len th * (Resistance)---/ Vmp) BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYS1E11: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE -THE RECIPIENTS 238,1 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES (29) KYOCERA # KU2656ZPA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF SOLARCITY INC. ABB # PVI-6000-0UTD-US-Z-A Module: 29 Kyocera 265W 1000V 238.1 Inv Power WPTC Voltage Drop Calculations Version 5_8.0 Vdrop = Im '* 2 * Len th * (Resistance)---/ Vmp) Inverter 1: 1 ABB PVI -6000-S AFCI 0.96 6000 6663.23 Kyocera 265W 1000V 238,1 Module: 1 Imp A Max. Length(ft) Wire Inverter 2: String: 8.55 35 AWG #SO at Max Ave Hi: 109 deg F . Module: Inverter 3: Vdrop = 8.55 70 0.00124 Ohms / 339.53 0.22 Branch: 8.55 50 AWG #10 at Max Ave Hi: 109 Vdrop = (8.55. 100 0.00124 Ohms) / 403 0.31 Total volts a dro in DC conductors = 0.53 Inverter: 28 151 AWG #8 at 240V Vdrop = (28 30 0.00078' Ohms) 240 V 0.08 Combined at 240V deg F Kyocera 265W 1000V 238.1 Module: Inverter 4:. Kyocera 265W 1000V 238.1 Total: 29 Modules Total Inv Pwr: 6000 6663.23 PTC Photovoltaic Module Electrical Specifications: Total STC:I 7685 Vdrop = Ohms) / 240 V Voc: 38.3 V deg F deg C Vmp: 31 V Record Low Temp: 14 -10 Total voltage drop in AC conductors = FO.08 Isc: 9.26 A Max Average Hi Temp: 109 143 Total voltage drop in AC and DC conductors.= Imp: 8.55 A Record Hi Temp: Tvoc: -0.14 V/deg C �l Tisc:j 5.56 mA/deg C i String Type A and 2 Combined Strings Type A -V Voc Correction Method: Manuf TV Data Branch Circuit Type A 1 way wire length: 50 Voc Correction Factor: ABB PVI -6000-S AFCI Inverter Min Vdc Input: 13 Kyocera 265W 1000 Min Vmp at Max Temp: Voc= 497:9 ~t 40+ Max Voc at Min Temp: ,Vmp= 403) ! Inverter Max Vdc Input: Isc= 9.26 j Max String Size: Imp= 8:55 wire length: Icont= 11.58 ( Art 690.8(A)(1) 2 strings per branch 1strings 8 modules per series string Voc= 306.4 V Vmp= 248 V Isc= % '18.52 A Imp= 17.1 A Imp= (cont= 23.15 A per branch 2 13 1 modules per series string Voc= 497.9 V Vmp= 403 V Isc= 9.26 A Imp= 8.55 A Icont= 11.58 A Art690.8(A)(1) 130 339.53 560.64 600 13 50 I a iConductor: 1 AWG #10 PV Wire 2.a Conductor 1: AWG #6 Conductor 2: AWG #10 Icont 1.25 = (Amps) 14.47 Conductor 1 Conductor 2 --� _J-30 deg C ampacity = 401 Icont * 1.25 = (Amps) 30 deg C ampacity, = 28.941 14.47 751 40 1.b' Icont= (Amps) 11.58 2.b Icont= (Amps) 23.15 11.58 Start ampacity 40 75 40 Temperature derate (%=F) 0.41 Start ampacity 0.41 0.41 Conduit fill derate (%=#) 1 Temperature derate (%=F) 0.8 0.8 Derated ampacity 16.4 Conduit fill derate (°/a=#) Derated ampacity 1.0 24.6 13.12 2.c Term 1 Term 2 (cont * 1.25 = (Amps) 14.47 Ampacity 40 Temp table 90 °C:Ta®01c 20.15(B)(16) (cont*1.25= (Amps) Ampacity 28.94 14.47 75 40 1.d Icont * 1.25 = (Amps) OCP Size= 14.47 15 Inverter Type A Output , 2.d OCP Size 1 301 15 - Combined Inverter Output w ABB PVI -6000-5 AFCI 1 way wire length: 15 ft (cont = 281 A Art 690.8(A)(1) Service Voltage= Total Inverter Powe - 1 way wire length= 15 3.a Icont * 1.25 = (Amps) 35 Art 690.8(B)(1) ` 35 OCP Size = Art 240.6(A) Icont = # of inverters*max inverter (cont = (Amps) current Art 690.8(A)(1) 3.b Conductor: AWG #8 .Icont * 1.25 = (Amps) 30 deg C ampacity = THWN-2 at 90 deg C: Table 310.16 35 _55 4.a Icont*1.25 = (Amps) OCP size,-- • 35 Art 690.8(B)(1) Art 240.6(A) 35 4.b Conductor: AWG #8 (cont * 1.25 = (Amps) 30 deg C ampacity = THWN-2 at 90 deg C: Table 31.0.16 35 55 3.c Icont = (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%=#) Derated ampacity eraont p 28 55 0.82 4.c Icont = (Amps) Start ampacity Temperature derate (%=F). Conduit fill derate (%=#) Derated ampacity 28 .1_1 55 .1 45.1 0.82 3.d * 1.25 (Amps) Ampacity 50 1 45.1 4.d Icont * 1.25 = (Amps) 35 r. 50 Ampacity JACQUES, CARLY 52165 AVENIDA VALLEJO LA QUINTA, CA 92253 7606258705• JACQUES RESIDENCE 7.685 ' KW PV ARRAY PAGE NAME ELECTRICAL CALCULATIONS DESIGN: Chris Wachter SHEET: REV DAIS PV 7 a 9/23/2015 . ;;SolarCity. 3055 Clearview Way San Mateo, CA 94402 1(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solarcity.com Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC;) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: . (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.13.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED CITY OF �.QVIDE DEPT . �,� BUILDING &SAVED .. ---� APPF; , FOR CONSTRUCTION r BY h ,.: ; DATES—� f + —A F"? (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR `��\"!w 3055 Clearview way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED+= ■ San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set.�\lz T:(650) 638-1028 F:(650) 638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE /���arC�t (888)-CIfY(765-2489)wwwsolarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. • - . .J A `n^SOiaftlty I ®pSOlar , Next -Level PV Mounting Technology f solarCity. I ®pSiilar Y M - ',.' Nett -Level PV Mounting Technology, . • y ' ., Coponents • ,.� ..�, - • ' � � �+;- s. .y - Zep System m for composition shingle roofs N `014 v4T'e�� Zescription 1 Iii PV mounting solution for composition shingle roofsWorks with all Zep Compatible Modules• ► F • Auto_ bonding UL -listed hardware creates structual and electrical bond - c ` z _ Zep System has a UL 1703 Class "A" Fire Rating when installed using j, [ U modules from any manufacturer certified as "Type 1" or,"Type'2" Comp Mount Interlock `+Leveling Foos ®� LISTED Y Part No. 850-1382 Part No. 850-1388 ..Part No. 850-1397 t r u Listed to UL 2582 & Listed to UL 2703 Listed to UL 2703 ' Specifications s -• - Mounting Block to UL 2703 Designed for pitched roofs 5 ` • Installs in portrait and landscape orientations _ I •` • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703- • Wind tunnel report to ASCE 7-05 and 7-10 standards ' Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 •� `• Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72" and cantilevers up to 24" - - - • Zep wire management products listed to UL 1565 for wire positioning devices .'Ground Zep Array Skirt, Grip, End Caps DC Wire Clip Attachment method UL -listed -to UL 2582 for Wind Driven Rain ' _ Part No. 850-1172 Part Nos. 500-0113, Part No. 850-1448 Listed to UL 2703 and 850-1421, 850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 �.' Listed to UL 2703 • zepsolar.com • - � ,q zepsolaccom • . . t - ' cA This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for - ; '� This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for `. each product. The end-user documentation shipped with Zep Solars products constitutes the sole specifications referred to in the product warranty. The customer is solely , " each product. The end-user documentation shipped with Zep Solars products constitutes the sole specifications referred to in the product warranty. The customer is solely._ responsible for verifying the suitability of Zep Solars products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. - - responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. - •' 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf - Page: 1 of 2 ~ • k 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf - Page: .2 of 2 ` . ,..• ' L Designed for residential and small commercial PV installations, this inverter fills a specific niche in the ABB product line to cater for those installations producing between 5kW and 20M This inverter includes dual input section to process two strings with independent MPPT. The high speed and precise MPPT algorithm offers real-time power tracking and energy harvesting. Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. The wide input voltage range makes the inverter suitable to low power installations with reduced string size. The transformerless operation offers high performance efficiencies of up to 97.1%. Free remote monitoring capability available with every installation. This enables homeowners to view their energy production and offers installers a proactive and economic way of maintaining and troubleshooting the system. Highlights: — Single phase and split phase output grid connection. — Wide input range for increased stringing flexibility. — The high speed and precise MPPT algorithm offers real time power tracking and improved energy harvesting. — Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions. — Integrated DC disconnect switch in compliance with international Standards (-S Version). Power and productivity M EQ EQ for abetter world r" pRiuD LD Additional highlights: — RS -485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and Interruption (-A Version). An Technical data and types 2 ABB Solar Inverters I Product flyer for PVI-5000/6000-TL-OUTD A ` CUTTING EDGE TECHNOLOGY As -a pioneer with four decades of experience in the development of photovoltaic systems, Kyocera drives the market as a leading provider of PV products. We demonstrate our Kaizen philosophy, or commitment to continuous improvement, by setting the industry standard 'f: in the innovation of best -in -class solar energy equipment. -QUALITY BUILT IN UV -stabilized, anodized aluminum frame i•n black • Supported by major'rnounting structure manufacturers • Easily accessible grounding points on all four corners ! for fast installation •Proven junction box technology with 12 AWG PV wire 5 1 ` works with— transform inverters - - t • Amphenol H4-UTX locking plug-in connectors provide safe, quick connections PROVEN RELIABILITY • Kyocera modules confirmed by the Desert Knowledge ' Australia Solar Centre to have the highest average output of any crystalline module " • First module manufacturer in- the world to pass long- term sequential testing, performed by TOV Rheinland • Only module manufacturer to achieve the rank of ` "Performance Leader" in all'six categories of GTM �- Research's,2014 PV Module Reliability Scorecard CERTIFICATIONS • UL1703 Certified and Registered, UL Module Fire , Performance: Type 2, CEC ' • NEC 2008 Compliant, IEC 6121561730, and ISO 14001 tIT4 PA (Dus �TJ �QCOMPPSv ��SRIY." L71iJ►7t 0 0 • 0 0 0 L' ��A� • L KU -60 1000V Series ELECTRICAL SPECIFICATIONS MODULE CHARACTERISTICS , • . , . • . • Cells per module: 60 (6 x 10) i 111 Dimensions: 65.43inf 38.98in/ 1.57in length/width height (1662mm/990mm/40mm) Weight 45.2lbs (20.5kg) -LP '265' w .I a I 1 r' • IVmP i ; 31.0 V t Im° 8.55 A 38.3. l V. i lu 9.26 A P.—n-ce - +5/-0 % IF 1111 I II • • 45 .°C Pmaz ti 191 w . V� 27.9 V Imp 6.85 : - h A-- V0C 35.1 V �Iu 7.49 t A f PTC 238.1 w ' IP_ -0.45 `LLLLLL IVmp _ -0.48 - 1 %I°C f ImP 0.02 `I .•0.36 - = %l°C 0.06 %J°C Operating Temp -40 to +90 Yr °C Series Fuse Rating 15A Maximum DC System Voltage (UL) 1000V Hailstone Impact in (25mm) @ 51 mp (23m�s) PACKAGING SPECIFICATIONS Modules per pallet 20 - Pallets per 53' container. 36 _ Pallet box dimensions: 66in/40in/43in length/width/height (1675mm/1005mm/1055mm) Pallet box weight: 1015lbs (460kg) 1.57" a (4� ,6 T JUNCTION BoxPO9Pss)TEO CABLE W/ ❑ r r - CONNECTOR LABEL -- • - - - ' . _ f. -x - 98.98" (990mm) "r -CO � • ` Grounding Hole Slotted Mounting We 0.16' (4oW 0.35'x0.47- (9om I2m) FRAME CROSS SECTION DIAGRAM 0.41- n4Y,1 , - 1. se-t3smt 'Subject to simulator measurement uncertainty of +l- 3%. - KYOCERA reserves the right to modify these specifications without notice. LONG/SHOMT SIDE * WARNING: Read lhCinsNUClion I ' • Qmanualin its ming& prior t- ' handling. installing B opoml- ing Kyocera Solar modules. 040215 Pl OUR VALUED PARTNER 3 i . L c 0 AI ouvN l CO, N%�DNWROVTS � OWN111Y D KNOCNOUIS MR NOTG 1-1/2 CON WR 1. MEECC MWEN9ON5 IN RaWMEfERS) ARE S G- W NETS. 2 ME RANGE Of LUGS 6 1/0—/14 COPPER OR AL MU. ' •' °wm� 0. P. lIM9:� e C DIMENSON SMELT CO AMP ttPE ]R GENERAL DULY Nq -IT T-95-1451 o.�vw 8 7 6 5 4 3 2 1 I IB IA J ®r: ®' ZS COMP I GROUNDING AND BONDING • � - � � • � � Zep So -lar ZepSolar - r , „ . _ Interlock = •_ t ZS CompTM I Grounding'and_ Bonding -_- - - _ _ 'Interlock Zep J = f - f 4 - [ •` • . '.. ' :q, "�Key side ` This document describes the mechanics of how the electrical bonding is accomplished between the UL f Listed hardware components used in Zep Solar's ZS Comp mounting solution for composition shingle roofs. r - ` - ' - .. - ` • A Part No. 850-1386 - • ., •'i •l Zep CompatibL&TM systems do not require running copper conductors to each module. The act of physically^ I. UL Listed to UL 2703 / 7 _ r installing each component simultaneously establishes an electrical bond, as described in the following . "Tongue side f;,. pages. -Key Side Bonding r .�€• - 2 ,, f •.~,r• Cutting -tooth- a �^ —Side view. _ Interlock -• tiv 7— 7e— •l 4.dule i • e , ._ �F L`y�� • m.w . - _ _ 1. - • f 1 rGround Zep - - Interlock(Key side shown(Key side inclosed position ® - - _ Bonding locations- - Zep Compatible module on Ke side - ' _ Cutting 'tooth" n y Forced interference during rotation - with Zep Groove " - of Interlock Zep causes teeth to • } - - cut through anodization on module y - - - Kq frame, resulting in robust and UL • - �.,-w-Vii,,-•nom �•"""'"'�'r� - certified bonding path . Side Bonding Tongue Tongue side in closed position , 'Leveling Foot O Module O ` Down -roof � ' ZS Comp Cutaway Illustration '? •,(. 1 • :Forced interference between mating parts from module - • - :--k Cutting "teeth" - .Bondinglocation on �' •X rock -in motion cuts into module frame, removing Tongue side anodization and resulting in robust and UL certified bonding path ,., Doc umentB00-1478-001Rev A' „ www.zepsotar.com - - .• - R Document 800-1478-001 Rev A www.zepsotar.com PAGE:20f$ PAGE: 1 of 5 ©2013fENZep Solar. Ina Zep Solar reserves the right tomake specifications chnageswithout any prior notice. All rights reserved. • ©2013/ENZep Solar. Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25, 20134:45 PM - -�" - Date Last Exported: June 25, 20134:45 PM AIM W. ZepSolar Interlock, continued ""M Part No. 850-1388 UL Listed to UL 2703 Bonding Path - Key and Tongue Module Interlock ZS COMP I GROUNDING AND BONDING The Interlock bonds modules on all 4 sides to create a hyper- hond?d ?,ray whara ovary mndula Is strurtrrrally and electrically bonded to the surrounding modules. 1 Tongue side Bonding Path - Array 1101, � as )1z" da hIN `KILIN `Ila o Interlock Bonding path 1 Down -roof Key side CW. ZepSolar Leveling Foot ZS COMP I GROUNDING AND BONDING Tongue side .0- --------► Key side Spring clip Part No. 850-1397 The Leveling Foot top portion (the Rockit) has a stainless steel UL Listed to UL 2703 spring clip that bonds to the adjacent module frame on both Key and Tongue sides. Leveling Foot - Bonding With Module Frame Key side inserts into Zep Groove (rock -in) Module in next row drops in on the Tongue side Bonding Path - North and South Modules ®-® ® Leveling Foot Nk .#,— ®_- ® Bonding path ,r a� Bonding location on Key side Bonding location on Module rotation during drop-in creates forced Down -roof Tongue side interference between Zep Groove and spring clip, cutting into module frame, removing anodization and resulting in robust and UL certified bonding path Document 800-1478-001 Rev A www.zepsatar.com PAGE: 3 of 5 Document 800-1478-001 Rev A www.zepsolar.com PAGE: 405 02013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. 02013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25, 20134;45 PM Date Last Exported: June 25.20134:45 PM • r � Insert copper EGC into ground wire •� •. •• .S • .. •an army perimeter'' �� is pointing straight up. , �• ��� channel. Tighten setscrew using torque r - _ .y i �`�'^f• - ' _,yr °' 7 • - t'•.A r� • values shown in the ZS Comp Installa- - ' i• „ i . _ ... . rt r • - tion Manual. ' t' ^ - `'t, ' ! + , , • • • ,,. . " - - Bonding Path: -;Array to Ground • " ..1 . _� O •Ground Zap .. . -, • - t r . , i} • r , . ' ,' .. , Z p.Solar • : ' , Zs COMP I GROUNDING AND BONDINGA. " . • Equipment Ground , " + - r .. Conductor - - . f . •' - - . t- . • 'r • - - - - 'Bonding path • '. � •� : •_ {', ;_� - � . -; ..., .. � . ' :� - - -, —_ _ -- . • . - .. - ' �. • ` Ground Ze P .' .,, �.�: , .�` .. • � . • .Y 1. .- 1 Down -roof .. . - '• .... - 'r • . r Document 800-1478-001 Rev A www.zepsatarcom • - - .� - - '• - - " t _' _ --t'- - -_ it - "- PAGE: 50f5 -ry - °- .,• .. _ LLt _ - ,'c.- •% -. ..1, _ ~_ •-,.:"' . -.�•. -= 4 `• .- .. -i - .. - - _ v • - - _ _. • ,' s• Setscrew f I Date LastEzported: June 25.20134:45 PM .. : i - � ' ; f u -•� - �' a Key side - t . .''4 .�• .. !. � t _ a• • ''t .'+ } , s The Ground Zep provides a single point of connection for i- - •,;' r ♦ - .., ` the Equipment Grounding Conductor (EGC) from the array . :' '- !, •' - •, '!� r'i .1 • r - too building ground. - - - - ` , + - t. _ !; ,.,r ' •! �i • + •` ', 4 x_ •Ground wirechannel • ; p • a .� .., 1 .. •• , •. �t�• , • ' t. • s • , - w , • .. _ � (� { ` ,. _ i • r �,, " . - r IIS, , - . 4 " . , ♦ 'Y. • - _ . - _ r. ' • 'Pail t.e l 1 .. t' i [ y - 4„ •��� , ' • •1.y,-. r' .r `� > _ .. ,. , •-.. ,. ••. v +. ,w, i N r. ... .•_ - •. Js j d .. .•. .,. M j - •.� .• . , .-� n ,-.. _ `1 c - _.. ' x - L •f M• . r ..' m--. - •• • ♦ ♦ . �. ... r..r ..t,. ., ~r .. . X • t .., ,a° � .. :.. A -'y~ . •' . � � .rt • . � 't . . r w v . . - . .. , Part No. 850-1172 '' V 'i - • UL Listed to UL 467 and UL 2703. E r - + .• .. ., r r. 4 `.�, 'S Yf i. � � 1 � r .` `t : '" 2 J ti ♦ �-.. ... a r et �.v Ground2ep Installation,'- • r � Insert copper EGC into ground wire •� •. •• .S • .. • - " _ Insert Ground Zep into Zep Groove of module frame, Use the Flat Too to rotate the Ground Zep 90 degrees, so that set screw Insert copper EGC into ground wire •� •. •• .S • .. •an army perimeter'' �� is pointing straight up. , �• ��� channel. Tighten setscrew using torque r - _ .y i �`�'^f• - ' _,yr °' 7 • - t'•.A r� • values shown in the ZS Comp Installa- - ' i• „ i . _ ... . rt r • - tion Manual. ' t' ^ - `'t, ' ! + , , • • • ,,. . " - - Bonding Path: -;Array to Ground • " ..1 . _� O •Ground Zap .. . -, • - t r . , i} • r , . ,' .. , • : ' , -r Equipment Ground , • • • > + - • - .. Conductor - - . f . •' - - . t- . • 'r • - - - - 'Bonding path - .. . - • •� - - - r - _ - - -, —_ _ -- - • -t • • s • .Y 1. .- 1 Down -roof .. . - '• .... - 'r . ! ' r ! Document 800-1478-001 Rev A www.zepsatarcom PAGE: 50f5 ' m 2013/EN Zep Solar. Int Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. _ • Date LastEzported: June 25.20134:45 PM SolarCity Standard Box 4J The SolarCity Standard Box 4J is a 4 -String unfused Junction Box. The box is highly configurable and adaptable using the (4) jumper blocks included in each box. A factory installed cordgrip enhances installer productivity. f ra4 440a".Ml.aa�' 3 o October 2013 • Manufactured to meet UL 1741 Standards. • Non -Metallic, Corrosion Resistant NEMA 4X Enclosure. • Factory -Installed Cordgrip Enhances Installation Speed. • Break-Thru Skinned -Over Glands on Cordgrip Provide Weathertight Seal for All Configurations. • Easily Configurable Terminal Blocks Permit Adaptation to Site -Specific Stringing Needs. Technical Data / Specifications OA Voltage Rating [VDC] : 600V © Maximum DC Current [A]: 57A © Maximum Continuous Current [A]: 42A OD Maximum Voltage NDC]: 600V Wire Size Range [AWG]: #6 to #14 Enclosure Rating: NEMA 4X © Operating Temperature Range [°C]: -40 to 50 ©H Typical Overall Dimensions [in]: 8"x6"x4" NOTICE OF COMPLETION UL AND AUTHORIZATION TO APPLY THE UL MARK 12/2112013 Solarcity Corp Alex Yang 3055 Clearview Way San Mateo Ca 94402-3709, Us Our Reference: E318537, Volume 1 Project Number 4786083586 Your Reference: A.Yang 10/7 Project Scope: Investigation of Photovoltaic (PV) System Combiner Box, model "SolarCity Standard Box 4C" and Photovoltaic (PV) System Transition Box, model "SolarCity Standard Box 4J" to UL 1741 Standard. Deer Alex Yang Congratulations! UL's investigation of your product(s) has been completed under the above Reference Number and the product was determined to comply with the applicable requirements. This letter temporarily supplements the UL Follow -Up Services Procedure and serves as authorization to apply the UL Mark at authorized factories under UL's Follow -Up Service Program. To provide your manufacturer(s) with the intended authorization to use the UL Mark, you must send a copy of this notice to each manufacturing location currently authorized under E318537, Volume 1 and including any special instructions as indicated in the addendum to this letter. Records in the Follow -Up Services Procedure covering the product are now being prepared and will be sent in the near future. Until then, this letter authorizes application of the UL Mark for 90 days from the date indicated above. Additional requirements related to your responsibilities as the Applicant can be found in the document "Applicant responsibilities related to Early Authorizations" that can be found at the following web -site: http-:/twww.ul.com/EAResponsibilitlo Any information and documentation provided to you involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. We are excited you are now able to apply the UL Mark to your products and appreciate your business. Feel free to contact me or any of our Customer Service representatives if you have any questions. Very truly yours, Jon Adonay 408-7546630 Engineering Associate Lead Jon.Adonay@ul.com NBKD9C5-90BA67 Reviewed by: William R. Carney 847/664-1088 Chief Engineer Director I W'illiam.R.Camey@ul.com This is an electronically generated letter. Signatures are not required for this document to be valid. Page 1 of 1