08425 (SFD)
6 44 P.O. BOX 1504 N o . Building 78-105 CALLS Address �j3-2�j V�,�eQ LA QUINTA, CALIFORNIAORNIA 92253 Owner Mailing Address e City ir__ Tel. Oceauelde Contractor City - Zip Tela State Lic. City & Classif. Lic. # —'Arch., Engr., I Designer Address Tel. CityI Zip I State I Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. _SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Buslness and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any, structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 ' (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). �,as owner of the property, or my employees with wages as their sole compensation, will �� d"0 1he work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not, apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or Improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions! ode: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner * y- WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ anyperson in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, atter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-. mentioned property for inspection purposes. Signature of applicant -Date- Mailing ateMailing Address City, State, Zip I BUILDING: TYPE CONST .P. Number i76 -053 -AIA Description Description iS.FJJ,. OCC: GRP.: 08425 Sq. Ft. No. No. Dw. Size Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation 8.3-302,00 PERMIT AMOUNT Plan Chk. Dep._ Plan Chk. Bal. nC Const. 567.500 Mech. 3 Electrical .00 20.675 Plumbing 16 S.M.I. _ 0 Grading ��- Driveway Eno. ` Infrastructure TOTAL e REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date t� jinn Permitgo Validated by: Validati CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SQ. FT. ® $ UNITS A.C. UNIT 2ND FL. SQ. FT. SLAB GRADE Z YARD SPKLR SYSTEM POR. SQ. FT. ® MOBILEHOME SVC. BAR SINK GAR. SQ. FT. ® POWER OUTLET I ROOF DRAINS CAR P. SQ. FT. DRAINAGE PIPING WALL SQ. FT. DRINKING FOUNTAIN. SQ FT ® ROCKSTORAGE URINAL ESTIMATED CONSTRUCTION VALUATION $ GAS (ROUGH) WATER PIPING NOTE: Not to be used as property tax valuation METER LOOP FLOOR DRAIN MECHANICAL FEES REINF. STEEL WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRYTRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SQ. FT. @ c BATH TUB FRAMING"/?/ SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 11/4 c SEWAGE DISPOSAL /�f / ,/�G� SQ.FT.GAR ® 3/<c HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR' SETBACK 2 Ira 12A, ROUND PLUM BINGE "200 UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE Z ROUGH PLUM BONDING HEATING (ROUGH) STORAGE TANK FORMS SE Aff4KCROUGH WIRING. DUCTWORK ROCKSTORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM FINAL INSP. [/ GRADING cu. yd. $ plus x$ _$ LUMBER GR. FRAMING"/?/ FINAL INSP. ROOFING �� VENTILATION /�� �(7✓f� ^� � /�f / ,/�G� REMARKS: FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL THING MESH INSULATION/SOUND 2 FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated (619) 347-8631 Date 12/17/90 1 Type of Permit I La Quinta No. I 10331 Permit # 108425 Owner Name David Miller Log # No. 53-200 street Vallejo city LaQuinta zip 92253 study Area 111 APN # I I Tract # I Lot # Square Footage 11501 Type of Development I Single Family Residence No. of units Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 11.58 1 X 11.501 or$ 2,371.58 have been paid to D.S.0 S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By K. J. Martin Name on the check gy Richard M. Beck Director, Facilities Planning & Development Fee collected-/pzempted by Carlene Ellenz Telephone; i Payment Received Signature ( Check No. 4914 Collector: Attach a copy of County or City plan check application form to District copy. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting the real property in the City of La Quinta County of Riverside State of California, described as Lot 15 in Block 218 Santa Carmelita at Vale La1 ta as per map recorded in Book 20,.Page 22 of Maps,2urecords iof2l, Riverside County. t314,04-%41 A -N,0,774-,0.53.-.0.1.0. t <,>': � � a `,,,• ax .' � `=s,s, : � _J •Dated9 _ Marrh 1 , 1 UQ1 S NDad Ross Miller STATE OF CALIFORNIA Iss. COUNTY OF ) On LnLa &t'C -a(o' /9-9/ before me, the undersi ned, a "NotaryFublic In and for said State, per- sonally appeared �(u.- _; •. OFFICIAL SEAL personally known to me (or proved to me on the basis of satisfactory C. RENEE GODBEY Nofory Public•CcIllfornla evidence) to be the person(s) whose name(s) Is/ey k subscribed to the RIVERSIDE COUNTY COfilfl'tisronA! within Instrument and acknowledged to me that he/s q0k executed JIM*re . �9 the same. WITNESS my hand official seal. r , Signature (This area for .officlal notarial seal) 1002 (6/82) MAIL T STATEMENTS AS DIRECTED ABOVE "':'`' Order No. Escrow No. Loan No. .cif J SPR 5 COPY' 1991 ` WHEN RECORDED MAIL T0:09 n W61h],' • � LYT i�9e�:•;csti. Kevin J. Martin 33971 West Chester Drive ' b'°rh51C1Qjl F,1�SY�DCCif' • 'Thousand Palms, CA 92276 RP COUNTY, CALIFORNIA, SPACE ABOVE THIS LINE FOR RECORDER'S USE MAIL TAX STATEMENTS TO: as shown above DOCUMENTARY TRANSFER. TAX $.....None•••••• ••••••••••••••••••••••• ...... Computed on the consideration or value of property conveyed; OR ...... Computed on the consideration or value less liens or encumbrances remaining at time of sale. the undersigned Signature of Declarant or Agent determining tax — Firm Name ' GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, David Ross Miller, a married:..man hereby GRANT(S) to Kevin J. Martin, an unmarried man the real property in the City of La Quinta County of Riverside State of California, described as Lot 15 in Block 218 Santa Carmelita at Vale La1 ta as per map recorded in Book 20,.Page 22 of Maps,2urecords iof2l, Riverside County. t314,04-%41 A -N,0,774-,0.53.-.0.1.0. t <,>': � � a `,,,• ax .' � `=s,s, : � _J •Dated9 _ Marrh 1 , 1 UQ1 S NDad Ross Miller STATE OF CALIFORNIA Iss. COUNTY OF ) On LnLa &t'C -a(o' /9-9/ before me, the undersi ned, a "NotaryFublic In and for said State, per- sonally appeared �(u.- _; •. OFFICIAL SEAL personally known to me (or proved to me on the basis of satisfactory C. RENEE GODBEY Nofory Public•CcIllfornla evidence) to be the person(s) whose name(s) Is/ey k subscribed to the RIVERSIDE COUNTY COfilfl'tisronA! within Instrument and acknowledged to me that he/s q0k executed JIM*re . �9 the same. WITNESS my hand official seal. r , Signature (This area for .officlal notarial seal) 1002 (6/82) MAIL T STATEMENTS AS DIRECTED ABOVE "':'`' -'' •.• ^�" -�--_-.""•.i�'l'�.sL��.�a ,a� �ti f._ ,��+ . �+�` nom' .:.i ` COUNTY OF RIVERSIDE DEPARTMENT OF HEALTH A°seiOf P.fw Na /Dated ENVIRONMENTAL SERVICES DIVISION YRECEIPTNO x;�7�.''` PERMIT APPLICATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM �fv Applicant: Submit this form with four copies of a scaled plot plan (1-20 scale) drawn to County speculations as indicated on the attached check list tssuedBya3R�1.%Q+ A non-refundable filing fee (see below) is required when the application is submitted. Check must be made payable to the County of ' Riverside. Approval of this application shall remain valid for a period not to exceed one year from date of approval../ Q VERIFY ITEMS IN SECTION A FROM BUILDING & SAFETY APPLICATION BUILDING DEPARTMENT APPLICATION LOG #'(r v Z Q T Qt,r, (itIS� � �6 Address &Firm I, of n A PhI.0one Maili city f Staroperty Off to -Zi`i�p ?, Job Add �3Pf! Legal Description Pro Lot) Cv t t IS!Pk 19— it� Lot SizeWater Age y'lWaff Use of Permit P/P, CU, etc. Other 1-if(/UrJY t iii T GrjV'6'Lo�. MHSiteP � C;z1 rep, etc. `6 g 90 Signature of Applicant - r Date CATEGORY: REV CODE FEE CATEGORY: REV CODE FEE 'tf SUBSURFACE DISPOSAL 1238 ❑ SITE EVALUATION UPON REQUEST 7349 $ 43.00 m &$--57LQ0- ❑ MULTIPLE PARCELS WITHIN SAME(NO PLOT PLAN) LAND DIVISION ❑ SEWER/SEPTIC VERIFICATION 7348 $ 17.00 Z a 1 st 4 Parcels (Each) 1238 $ 57.00 (Less than 1 year) b. Each Parcel after 4 7344 $ 24.00 ❑. PRELIMINARY ELECTIVE 7352 $ 23.00 W .�O Rereview (2nd review same parcel) 7344 $ 24.00 EVALUATION (Attach DOH SAN 53) "❑ Site Evaluation in Conjunction with 0 HOLDING TANK 7351 $ 47.00 _ Critical Area 7346 $111.00 ❑ ALTERNATIVE/EXPERIMENTAL 7345 $222.00 ❑ She Evaluation Lot Less. than SYSTEM 10,000 Sq. Ft. 7347 $ 87.00 INITIAL DATE Holding Tank Agreements Completed ❑ Yes ID No Certification of Existing S.D. System Required p Yes No _ ! WOCB Clearance required. (Attach Form ❑Yes ©No DOH SAN 007, Santa Ana Region Only) Sails Percolation Report Required. ❑ Yes 31 No Special Feasibility Boring Report Required. ❑ Yes ) No Detailed Contour Plot Plans Required (1 to 5 M interval) ❑ Yes No Other ❑ Yes No Staff Specialist Lot Inspection Required ❑ Yes No Lot Inspection Date 4- Soils boring report by T' Project Date U Soils Map Page Sol Type Approved by 01? Deme Z O No. of System Type of Systems)ening ❑ Holding Tank ❑ Existing Unita B droon�Fixture Units (1) Septic Tank Soil Rate Grease G ntcp . / New. ❑ Replacenwnt Gal � (2) Leech Line SQ, Ft. area Sidewall albwence - ft.sq. fl Install :- Line(s) tLa with Leach Bed agft— per running tL ' n9 min. inchesrods below drak�l'r or/ of / ��/ Nq • Leachlines/bed special design for slope: (3) Pit Diameter No. Pits Pit Below Seepage PH Total Depth Other. Applicable Inlet (BI) (TD) Max. Allowable Depth vv , N/A � Overburden factor �� 6 / ' No. 2 System REMARKS: " This application rs.APDE PROVE /NIED for the category ch9dCted in SECTION B above, regarding the design of a subsurface disposal system as indicated . o�l on the accompa ied-plan, using the requirements set forth in SECTION C - above. A building permit is necessary for the installation of alar ZO above -designed system. No construction is permitted in the required reserved 100% expansion area. Septic tank and sewer lines must be 50' minimum from any wells .. (�Leach lines, must be 100'. minimum, from any wells, including expansion area W(3) Seepage„ pits must be .150' .minimum from any wells, including expansion area .• . : ; ti z Si nature: of- Health- Official-�/li��r�/r '/li1�Y�Lfi°t /k� 7 Date c /Dated YRECEIPTNO x;�7�.''` 1 �fv a tssuedBya3R�1.%Q+ dam% _� DISTRICT:, ❑ Riverside b Indio- ❑ : Hemet ❑ Perris - ." O Rancho Call ❑ _Blythe' DOH -SAN -122 (Rev. 3/90) .` DIS7IBlJr10N: ` WHrrE Office file YELLOW. Applicant PINK - Bldg. Dept GOLDENROD.., Plans/Records k ' it� - OFFICE OF " +�h AGRICULTURAL COMMISSIONER AND �:; ;t:• WEIGHIS & MEASURES CALVIN c:'KAMINSKAS 4000 LEMON SIREUROOM 19 nE+i Com+nl++l •� .JAMES O. WALLACE. CE CLEMENEN( OENVENISNISIE • ApikhAhaol Commhdo�m RIVERSIDE, CALIFORNIA 92501• sso�er Dh�olot d W�Iphii s (714) 707-2561 49613 Highway'86, Suite B12 `Coachella, Ca. 92236 (619) 342-8291 �C pwl 9 2 -7q o DA'I'S 9'0 — C11Sl; No.. 1_ j��- -MVEUOFER'S car Es >C. + • `• ' S.3 _u 3d ���;� J A Com,✓ �Gfz� ADDR60 L��t • 'IELEP{K�lEt (S I�lj • - � � LI � �� i ,al Dear Developer: After reviewing your landscaping plans, all plant material listed is not in ;ri • violation of quarantine -laws governing tile Coachella Valley. If substitutions do occur and- they differ iron plant material listed, tilis office must be motified . . immediately. . �i Thank you for protecting and preserving the Coachella Valley's pest-free.enviro(ment. - G (i- Qc/w • alt _ ural W n ss oner s Off ce i cos Indio and Riverside Office ` , :L 11. Heating System. (SE or HSPF x Duct Eff = Eff SE) 0.72 x 0.84 = 0.6048 Zonal'Control: NO 12. Cooling System. (SEER x Duct Eff = Eff SEER) 9.00 x 0.83 = 7.47 Zonal Control: NO 13. Water Heating. Type SE Credit:, 12 Sum .7-10: 0 1 0 6 0 - -11 POINT TOTAL : 1 POINT SYSTEM SUMMARY. Climate -Zone: ------------------------------------------------------------------------ 15 P -2R Project Title:. DAVE MILLER Date:.10/12/90 BUILDING DATA. Glass Area °Glass Conditioned Floor Area: 1502 SgFt'. North 33 : 2.20 Number of stories: 1 East, 33 : 2.20 . Slab/Raised Floor: SLAB South 70 : 4.66 Single Family Detached: X West - 40 : 2.66 Single Family Attached: Skylight 0 : 0.00 Multi -Family Totals 176 :11.72 Addition Alone Existing Building . Existing Plus Addition: ----.------------------------------------------------------------------- SCORE CARD Measures .' Point Score 1. Ceiling Insulation R: 38, or U: 0 2. Wall Insulation R: 19 or U: 0 3. Raised Floor Insulation R: 0 or U: 0 4. Slab Edge Insulation R: 0 or U': 0 5. Infiltration. Standard 0 6. Glass Heat Loss. Type U -Value .%Glass , : DOUBLE 11.72 5 Sum 1-6: 5 7. Shading (Shade Open) %Glass x SC = Eff %Glass a. North 2.20 : 0.77 1.69 0 b. East ' 2 .20 : 0.77 1.69 0 C. South 4.66 : 0.77 3.59 0 d. West : 2.66 0.77 = 2.OS : -0 e. Skylight 0.00 : 0.00 0.00 : 6 8. Shading (Shade Closed) %Glass x SC = Eff %Glass a.. North : 2.20 : 0.66 : 1.45 : 0 b. East : 2.20 : 0.66 : 1.45 : 0 c. South 4.66 : 0.29 : 1.35 : 1 d. West : 2.66 : 0.66 1.76 : -1 e. Skylight 0.00 : 0.00 0.00 : 0 9. Interior Thermal Mass : 2.30 0- 10. Exterior Wall Mass : 0.00 - 0 11. Heating System. (SE or HSPF x Duct Eff = Eff SE) 0.72 x 0.84 = 0.6048 Zonal'Control: NO 12. Cooling System. (SEER x Duct Eff = Eff SEER) 9.00 x 0.83 = 7.47 Zonal Control: NO 13. Water Heating. Type SE Credit:, 12 Sum .7-10: 0 1 0 6 0 - -11 POINT TOTAL : 1 CERTIFICATE. OF COMPLIANCE. RESIDENTIAL --^_--(.Page-1 of 2 ) CF -1R Project Title: DAVE MILLER Date: 10/12/90. Project'Address: LA QUINTA Documentation Author. Energy Consu'lting'Group,, 1-800-262-9966 .Compliance Method. Point System. Climate zone:.15 ----------- Enforcement Agency Use Only. Building Permit # Checked by/date. -------------------------- ---.-------- ------- ----------- --------------- GENERAL.INFORMATION Total Conditioned Floor Area. 1502 SgFt: Building Type. SINGLE FAMILY DETACHED Front Entry Orientation. WEST Number of.Dwelling Units.- 1 Floor Construction Type. SLAB Infiltration Control. STANDARD BUILDING SHELL INSULATION Component Type Wall Wall Roof Roof Floor Floor Slab Edge GLAZING Insulation R -Value ------------------ 19 38 0 0 Location/Comments ----------------- TYPICAL, FIBERGLASS BATTS TYPICAL, FIBERGLASS BATTS Glazing Area Glass Type Interior Exterior Overhang Frame Type Orientation (sf) Si•ngle,etc. Blinds sh screen yes/no metal/'wood Front W 40 DOUBLE NONE NO ------------------- NO METAL Front Left N 33 DOUBLE NONE NO NO METAL Left Rear E 33 DOUBLE NONE NO NO METAL Rear Right S. 70 DOUBLE LIGHT NO NO METAL Right VENETIAN Skylgt 0 Skylgt ------------------------------------------------------------=------=-- THERMAL MASS Type/Covering Area ( slab , exposed) ( sf ) --------------- ---- TYPE 1 TILE 0385 TYPE 2 CARPET 1207 Thickness Location/Description (inches) (kitchen, bath, etc.) --------- ------------- -------- 3.5 KITCHEN, ENTRY;, BATHS & LAUNDRY, 3.5 REST OF HOUSE CERTIFICATE OF ------------------------------------------------------7---------------- COMPLIANCE. RESIDENTIAL(Page 2 of 2) CF -1R Project Title: -------------------------------------------------- DAVE. MILLER Date: ; 10/12/90 SYSTEMS. Minimum Duct Type(furnace, Efficiency' Location Duct Output- Mfgr/Model# a/c , . hp, etc.) (SE , SEER , HSPF )( attic , etc ). R -Value (Btuh) '( or apvd equal) ----------------------------------------- ---- ------------- HEAT PUMP -HEATING 0.72 ATTIC 6.3 HEAT PUMP -COOLING 9.00 ATTIC 6.3 Maximum Furnace Heating Output: 53290 Btuh. HOT WATER SYSTEMS. Tank Manufacturer/Model# System Type Capacity (or approved equal) Special Feature(s) ----------- -------- ----------------- ---------------- STORAGE ELECTRIC 40 HWS REQUIRED R-12 External Blanket on Storage Tank (Yes or No) NO ----------------------------------------------------------------------- SPECIAL FEATURES/REMARKS: HEAT RECOVERY UNIT (HWS)TO BE INSTALLED WITH WATER HEATING ELECTRIC STORAGE TANK PER CITY OF LA QUINTA. LIGHT VENETIAN BLINDS REQUIRED IN SOUTH FACING WINDOWS. ------------------------7---------------------------------------------- COMPLIANCE STATEMENT. This certificate of compliance lists the building features and perform- ance specifications needed to comply with Title 24, Chapter 2-53 and Title 20,,Chapter_2, Subchapter 4, Article 1 of the California Admin- istrative code. This certificate has been signed by the individual with overall design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of the building. When this certificate of compliance is submitted for a single building plan to be built in multiple orienta- tions, all building conservation features which vary.are indicated in the Special Features/Remarks section. DESIGNER. BUILDING OWNER. (signature) ( date ) DOCUMENTATION AUTHOR. W. J . FINNELL #473969 ENERGY CONSULTING GROUP Indian Hills Box 34F Mountain Center, CA 92361 1-800-262-9966 (signature) 10/12/90 (signature) ENFORCEMENT Name Title Agency. Telephone_ AGENCY. ( date ) (signature/stamp) (date) THERMAL MASS WORKSHEET WS -1R Project Title: DAVE MILLER Date: 10/12/90. -------------------------- ---------------------------------------------------------- INfEPIOR THERMAL MASS: Use one of t -he two'following options for calculating interior mass as explained in Section 4.2 of the Energy Conservation Manual .(ECM). Method B must be used for mass elements that have an interior unit mass capacity less than.1.7: Method A: Look up the Interior Mass/CFA-value from ECM Table 4-7 reprinted on -the reverse side of this page. Type 1 mass has'a Unit Interior Mass Capacity (UIMC) greater than or -equal -to 4.2 (.see ECM Tables 4-8a and 4-8b'reprinted on Attachment). Type 2 mass has an UIMC greater than or equal to 1.7 and less than 4.2. Mass % is the mass surface area divided by conditioned floor area (CFA). For mass elements exposed on both (two) sides to conditioned space, enter the area of only one,side to calculate the percentage. Mass % Type 1 Mass Area: 0385.0 = 26 Type 2 Mass Area: 1117.0 = 74 Interior Mass/CFA from Table 4.7 = 2.3 Method B: Calculate. the Interior Mass/CFA value using the worksheet space below. Look up the Unit Interior Mass Capacity (UIMC) for each interior mass surface in ECM Tables 4-8a, 4-8b and 4-9 reprinted on the Attachment. Include the interior surfaces of. exterior mass walls. For interiorimass walls exposed on both (two) sides to conditioned space, enter the surface area of only one side. Include the inside surfaces of exterior mass walls as explained in Section 4.2 of the ECM. Unit Interior Interior Description Mass_Area x Mass Capacity = Mass Capacity -------------------------------------------------- (Intentionally left blank) Total / CFA = Interior Mass/CFA ------------------------------------------------------------------------------------ EXTERIOR WALL THERMAL MASS: Calculate the Exterior Wall Mass of all exterior walls. Look up the Exterior Mass Factor for each opaque wall element from ECM Table 4-9 reprinted on the Attachment. Only exterior mass wall surfaces may be included in this calculation. Opaque Exterior Description Wall Area x Mass Factor = ---------------- --------- ----------- (Intentionally left blank)' Total / Total Opaque = Exterior Wall Area Wall Mass . HVAC EQUIPMENT SIZING Design Location: LA QUINTA Date: 10/12/90`. Compiled for DAVE'MILLER DESI.GN CONDITIONS .WINTER. .Outside db 29. F ; ., Inside db 70 FWinter Design Temperature Difference 41 F SUMMER Outside db 112 F Inside db 78 F Summer Design Temperature Difference 34 F -------------------------------------------------------- ----------------------- EQUIPMENT SIZING LOAD A. Sensible Ventilation Load 1.1 x 1 0.00 Vent. CFM x 34 Summer TD = 0.00 Btuh Sensible Load for Structure +.21537,98 Btuh Sum of Ventilation and Structure.Loads = 21537.98 Btuh Rating & Temperature Swing Multiplier x 1.15 Btuh Equipment Sizing Load - Sensible 24768.68 Btuh B. Latent Sizing Load 0.68 x 0.0 Vent. CFM x 0 gr. diff. = 0.00 Btuh Internal Loads = 230 x 6 number of people + 1380.00 Stuh Infiltration Load' + 8525.16 Btuh Equipment Sizing Load — Latent = 9905.16 Btuh -------------------------------------------------------------------------------- COOLING SUMMARY Total Sensible Gain: 24769 Btuh Design.Temperature Swings Total Latent Gain + 9905 Btuh Normal 3F (X) 4.5F ( ) Total = Sens. + Lat.= 34674 Btuh* ----------------------------=--------------------------------------------------- HEATING SUMMARY Total Heat Loss for Entire House = 25972.8tuh Ventilation CFM = 0.0 Winter Design TD = 41 F Heat Required for Ventilation Air = 1.1 x 0.0 CFM x 41 F= 0 Btuh Design Heating Load Requirement= 25972'.(house)+ 0 (vent)= 25972 Btuh* -------------------------------------------------------------------------------- MAXIMUM GAS FURNACE OUTPUT CA Energy Commission Stds Sec 2-5352(8) 1.3 [Design heat loss + ( 10 Btuh )( Area Sq .Ft . )] 1.3 [ 25972 + 15020 ] = 53290 Btuh *(Note) The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors must also be considered. It is the designers responsibility to consider all factors when selecting the HVAC equipment. compiled by Energy Consultina Grouo MANDATORY MEASURES CHECKLIST: RESIDENTIAL. DAVE MILLER 10/12/90 MF -1R ------------------------------------------ ----------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures 'regardless of the compliance approach used. Items marked with an asterisk (t) may be superseded by more stringent compliance requirements listed on the Certifi- cate of Compliance.. When this checklist is incorporated into the permit documents, the features noted shall be considered. by all parties as binding minimum component performance specifications for the mandatory, measures whether, they are shown elsewhere in the documents or on this checklist only. ------------------------------------------------------------------------------------------------------------------------=-------- 2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. YES DESCRIPTION ----------------------------------------------------------------=------------------------------------------------------- DESIGNER ENFORCEMENT Building Envelope Measures 2-5312(Exception I): Pipe insulation on steam and steam condensate return & recirculating 22-5352(a): Minimum ceiling insulation R-19 weighted average. R38 2-5318(d): Swimming Pool Heating. 2-5352(b): Loose fill insulation manufacturer's labeled R -Value. 1..System has: :2-5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to b. Weatherproof instruction plate on heater. exterior mass walls). R19 2-5352(k): slab -edge insulation -water absorption rate no greater than 0.3x, water vapor 3. Pool cover. transmission rate no greater than 2.0 perm/inch. YES 2-5311: Insulation specified or installed meets California Energy -Commission (CEC) quality standards. Indicate type and form. FIBERGLASS--BATTS YES 2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16 only. YES 2-5317: Infiltration/Exfiltration Controls' a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. YES b. Doors and windows certified. YES c. Doors and windows weatherstripped;.all joints and penetrations caulked and sealed. YES 2-5352(e): Special infiltration barrier installed to comply with 2-5351 meets CEC quality standards. 2-5352(d): Installation of Fireplaces. 1. Masonry and factory -built fireplaces have: a. Tight fitting, closeable metal or glass door. b. Outside air intake with damper and control. c. Flue damper and control. 2. No continuous burning gas pilots allowed.. HVAC and Plumbing System Measures 2-5352(g) and 2-5303: Space conditioning equipment sizing: attach calculations. YES 2-5352(h) and 2-5313: Setback thermostat on all applicable heating systems. YES =2-5316(a): Ducts constructed, installed and insulated per Chapter 10, 1976 UMC. YES 2-5316(b): Exhaust systems have damper controls. YES .2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. YES 2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. YES 2-5352(i): Water heater insulation blanket (R-12 or greater) for storage and backup tanks for solar water heating systems (first 5 feet of pipes closest to tank insulated (R-3 or greater). YES 2-5312(Exception I): Pipe insulation on steam and steam condensate return & recirculating Piping. 2-5318(d): Swimming Pool Heating. 1..System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater. c: Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clock. 5. Directional water inlet. Lighting and Appliance Measures 2-5352(1): Lighting -25 lumens/watt or greater for general lighting iri kitchens and bathrooms. YES 2-5314(c): Gas fired appliances equipped with intermittent ignition devices. YES 2-5314(a): Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC. Indicate make and model number. YES T'0 = D A V �-, M.ijL--,IZE R ' LA QU1N,TA•, CALIFORNIA 4 INVOICE S 1 set CEC Compliance Reports, 1502 Ftp Building = $50.00 �f Thank you, W. J. Finnell 11. Heating System. (SE" or HSPF x Duct Eff = Eff SE) 0.72 x 0.78 = 0.5616 Zonal Control: NO 12. Cooling System. Zonal Control: NO 13. Water Heating. Type (SEER x Duct Eff = Eff SEER) 9.00 x 0.74 - 6.66 SE . Credit: 0,e. Sum 7-10: 1 0 0 .•�� 0 0 POINT TOTAL : 1 F v POINT SYSTEM SUMMARY. Climate g------------------------------------------------------------- Zone: 15 ---------- P -2R ------------------------------------------------------------------------ Project Title: DAVE MILLER ------------------------------------ ----------------------------------- Date: 08/01/90 BUILDING DATA. Glass Area %Glass --Conditioned Floor Area: 1502 SgFt. North 70 ,= 4.66 idt ber of stories: 1 East 40 = 2.66 !`lab/Raised Floor: SLAB South 33 : 2.20 Single Family Detached: X West 33 :'2.20 Sin?lvtiFamily Attached: Skylight 0 0.00 Multi-F,a/mily Totals 176 :11.72 Addy},tion Alone Ex-�s,tt Building X.iting Plus Addition: -------------------------------------------------------------------- SCORE CARD Measures Point Score 1. Ceiling Insulation R: 38 or U: 0 2. Wall Insulation R: 19 or U: 0 3, Raised Floor Insulation R: 0 or U: 0 4:: Slab' Edge Insulation R: 0 or U: 0 5:. I;.nfiltration. Standard 0 6. Glass H.e..At Loss. Type U -Value %Glass DOUBLE - 0.65 : 11.72 : 5 Sum 1-6: 5 7. Shadi•ngf- ( Shade open) %Glass x SC = Eff %Glass a. Nojth : 4.66 : 0.77 : 3.59 : -1 bI.. East : 2.66 : 0.77 : 2.05 : 0 Vic... South : 2.20 : 0:77 : 1.69 : 0 d. West : 2.20 : 0.77 : 1.69 : 0 e. Skylight : 0.00 : 0.00 : 0.00 : 0 8. Shading (Shade Closed) %Glass x SC = Eff %Glass a. North : 4.66 : 0.66 = 3.08 : -1 k' b. East : 2.66 : 0.66 : 1.76 : -2 C. South : 2.20 : 0.29 : 0.64 : 3 d. West : 2.20 : 0.29 = 0.64 : 3 e. Skylight : 0.00 : 0:00 0.00 : 0 9.' Interior Thermal Mass : 2.30 -1 10. Exterior Wall Mass : 0.00 0 11. Heating System. (SE" or HSPF x Duct Eff = Eff SE) 0.72 x 0.78 = 0.5616 Zonal Control: NO 12. Cooling System. Zonal Control: NO 13. Water Heating. Type (SEER x Duct Eff = Eff SEER) 9.00 x 0.74 - 6.66 SE . Credit: 0,e. Sum 7-10: 1 0 0 .•�� 0 0 POINT TOTAL : 1 roj�`Ti'tjleil'DAVE MILLER,xcbe, Meth'odGENERAL- �ORM ]JONT tal Conditioned Floor Area 1502 SqFt.014, SINGLE FAMILY-DETACHEDQui lding Type..ntry orientation. EASTFront ENumberof Dwelling Units .Floor Construction Type. SLABSTANDARDInfiltration Control.BUILDING SHELL INSULATION19. TYPICAL,,' FIBERWaWallRoof 38RoofFAoorGlazing Area Glass Type Interior Exterior Overhang FT'etc Blinds sh screen yes/nol�etal/wood,Orie -on (sf SingleMEEfABLE NONENO NO33 LIGHTLeft S DOUBLEVENETIANRearNO METALRight N 70 DOUBLE NONE NO Right � � 5kvlRt O Skyl8t ' ---------__---_--_--`--------------------------------------------- --_-__-- ' THERMAL MASS .. Type/Covering Area Thickness Location/Description .(slab, exposed) (af) (inches) (kitchen, bath" etc.) � --_-_---_-_---_ ) TYPE 1 TILE ---- 0385 --__--_-_ 3,5 -__-__----_-_-__----_ KITCHEN, ENTRY, BATHS & LAUNDRY �TYPE 2 r:*gPET 1207 3'5 REST OF HOUSE ',�, i} • - - f rF ,,� - '' a }rv,h r t&ykOf r` .y� 1 + F ` . c.►. { fir' %¢' j +,5 1 't.y" i ' �µ: r «9d ".�'Cis�' T� 7` -2 . c r`r it2G, . -,.. w`d,!' :4 ] t w - r e M Imo. - �. k• t• '�` i i 3 `'ifs ►� fist «; � db 'a` t!" t:.', x �. e •' � . '.. t �a � j �'iw� 3� � � '�.�•- y." �` *'t`�°��� r� �d� �p,Y yytn f •, HVAC SYSTEh�S�•, 1-MI,Duca ���sr'•. ' •Ae - s t.L. r �1.. .1Y'rj fi d4 r� 4d'�r Type�.fur,nace,«•=Eff.iciencyJ Location ; ; l uet- r�Outpu ' M f.gr/Moder H•,> hp,etc_.)t('Sy,SEER,HSPF)(tattc,a3tCt)f'�/alUe'°(tuh')`torapvtgcta F �F ` , } r 1 +L ? �.FUR�FiCE -0.72 xa(ATTIC 2.1 `-�;`' Y's�.3i"." +.7i ` }"1. .1? --FAIR' CONDITIONER y .00 ' ATTICS `;� . 2 1-".,- yJP ,{(; ((Y+ �+,, +? ?i }" . � ♦ .. w• • -, :� , w * i ::s ..�`ii. �. "y"al a �: � .;sit d Maximum Furnace Heating Output: 53290 Btuh. ��' r .rte • 'F L.. t r•. a+. -4—t IF HOT -WATER SYSTEMS. tr ' • Tank Manufacturer/Modelii 'r *�_ 4 System Type Capacity (or approved equal) �]Sp®Gial F�ea.twe(s3 ----------------- ---- — —-- .i— : ��rT�r r �t •� y' . STORAGE ELECTRIC 40 r ` _ .� �dJr•a R-12 External Blanket on Storage Tank (Yes or,No) YES L''f ,.qir Y... t -----------------=-----------=- ----------- , ,� , 'u --------------- _r}_- .SPECIAL FEATURES/REMARKS: HEAT RECOVERY UNIT INSTALL:.ED,ON,;WATER HEA_Tr;R�,,rYi, LIGHT VENETIAN BLINDS IN SOUTH AND WEST WINDOWS. rrt °' -------------------------------------f— ----------- 'COMPLIANCE STATEMENT. _,,,*� F� This certificate of compliance lists the building features and-perforifi--, ,*: j u ance specifications needed to comply with Title 24, Chapter, 2 53 an I 0 `.. ' Title 20, Chapter 2, Subchapter 4, Article 1 of the California'Admi-n-�;'*ti`.',w 4,•J.. `� istrative code. This certificate has been. signed by the indiyi,duai' * }y ": •��: , .W'i:th overall design responsibility `and the building owner, wtio,:shal�l�,:�,f��;a„� . • :: retain a copy. of it and transmit the certificate to any subsequent. ;r ��;•, 'pu`rchaser of 'the building. when this certificate - of compliance? ism sus: ` '' ienta 'submitted for .a single building plan to be built in multiple or=.iQ��"y .1P # tions, all building conservation features which vary are indicated ink ther.:Spe°ei.a1 =F-eatures/Remarks section. 7.F 'M t �$;,IGNER . BUILDING OWNER. } 3 • 'Y 4 111 •� \ `A; signature) ~� ^ ( date) ( signature) (date) DOCUMENTATION AUTHOR. W. J. FINNELL ##473969 ENERGY CONSULTING GROUP Indian Hil1S Box 34'= Mountain Center, CA 92361 1-800-262-9.66 ( ignaturr; i _ 03/01/90 ENFORCEMENT AGENCY. Name _ Title Agency _ Telephone (signature/stamp) (date) I 01 HEATING, VENTILATING & :AIR "COND,1T,ZOIVING — DESIGN DATAk or" � s 1- LOCATION LA QUINTAj 2. DATE 08/01/90 3. COMPILED FOR DAVE MILLER r " "f 4. WINTER DESIGN TEMP 29_ 5. SUMMER DESIGN TEMP 112 -, . •6, CONDITIONED SO FT 1502 ., 7. WINDOW SOFT 176 U—VALUE -0.65 i 8. WALL SQ FT 1355 U—VALUE 0.05 1 9. SLAB FLOOR LIN FT 192 U—VALUE 0.81 -' 10. i2AI5FD FLOOR SO FT 0 U—VALUE 0.00 11. CEILING SO FT 1502 U—VALUE 0,03 12. CONDITIONED CU FT 13930 1'3. VENTILATION CFM 0.00 0 14. RS MULTIPLIER 1.15 s • 15, GRAINS DIFF 0 1 16. NO. OCCUPANTS - 6 _ 4 '.. v t., o-• .y. ! f 4 '+` '. �+1♦ k,�tt �+b rtr. .w "t Fsl •,t •i3` - `a -.!' r '�""v` 'i t# },7' -! r.�' 't,.* a �` 1" �;,.x.�r ''C Y;> - . w r i r .�f 1 -1 .h '. r•^ :a�"' S S s {3y 4 . r 4r � � .�r r �► � <r.w i s, 4 ,.a r '�'a. r r S � ,gg`s S � ��•. - �g V*�� t F+",� 4 v � .[1ar '� .. r� c r� � .:•S wd� `= x 114, y�, it 3si' i r! %•.i` - "" t 4 :e a i'r,.,. .. ,( �,• i �}�,C .yt,� s� .aTti ;�' {EATr �,Aliy`CAL:`Cl9L,ATION',, ! .� f.;�, % - v •+ � �� ��� .i is t'e'a ,. P.roposed ,Besi�i�nce LA QUINTS" ,,'.'sDnte• 08/QT` Y. Summer. Dpsn TetnPe�rtu"r ' 112 , �,: �k I Tr-'ansrnission Gain •.Windows; 4 176 SgFt x 0 .65"`x'; 34 x 1 Hr'7 Walls r i 1355 SgFt x 0.05 x 34 x 1 Hr j 2303 Spstuiak C: Floor (slab). 192 LnFt x 0.81 x .34 x '1,. Hr - 5287--68_;Bttah;-u. Floor (raised). ` 0 SgFt x 0.00 x 34 x Hr �.0 00 Btuh D. Ceiling 1542 SgFt x 0.03 x 34 x.1 Hr , rr� t 1532 64,LBtyh �e ;. E. Total Transmission Gain. 1 13012 82 _Btuh`G x -----.-------------------------------- ------------.---- —_� _... Y .�.;. ..a wl p•� � i rte, _ Ii. Infiltration Gain 13930 Cubic Ft. @ one Air Change/Hr. . !� 13930 CuFt x 0.018 x 34 x 1 Hr. , 8525.1 stuh � ____r _-_______------ ---__________ IIITo 21537.98-rBLih'Y� xta]Gain(I+II) fi j syjj __------------------- °tf HEAT LOSS CALCULATION -Proposed Residence= LA QUINTA Winter Design Temperature: 29 w r �'----------------- ------------------------------------------;---------- F I . Transmission Loss. 4x4 r y A. Windows. c. .. 176 GgFt x 0,65 x 41 x 1 -Hr. = 4690.40 Stuh a B. walls. ;A 135 �qFt x, G.05 x 41 z 1 Hr. = 2777.75 Btuh x . C. Floor (slab)- 192 LnFt. x 0.81 x 41 x 1 Hr. = 6376.32 Btuh Floor (raised) - 0 SgFt x 0.00 x 41 x 1 Hr. = 0,00 Btuh D. Cei.lifig . 1502 SqFt x 0.03 x 41 x 1 Hr. = 1847.46 Stuh E. Total Transmission Loss 15691.93 Btuh II. Ivif.i.ltration Loss. 13930 Cubic Ft. @ One Air Change/Hr. 139:s0 C�.aFt x 0 .018 x 41 x 1 Hr . = 10280 .34 Btuh III. Total Loss (I + II) _. tt 25972.27 Stuh ' r F 4 � t � i r '� � �•,11 i' [ C �l 4 '' -i Y ' V 7 --i � .J :. T b P _ l�. y. . 1 * � . - Y� f "� ' 4 .. t �'i �,-.� � ., Y: .,, ��� � J�•?ts�, h a. •r i '� sr' �. riff . 4 '.. v t., o-• .y. ! f 4 '+` '. �+1♦ k,�tt �+b rtr. .w "t Fsl •,t •i3` - `a -.!' r '�""v` 'i t# },7' -! r.�' 't,.* a �` 1" �;,.x.�r ''C Y;> - . w r i r .�f 1 -1 .h '. r•^ :a�"' S S s {3y 4 . r 4r � � .�r r �► � <r.w i s, 4 ,.a r '�'a. r r S � ,gg`s S � ��•. - �g V*�� t F+",� 4 v � .[1ar '� .. r� c r� � .:•S wd� `= x 114, y�, it 3si' i r! %•.i` - "" t 4 :e a i'r,.,. .. ,( �,• i �}�,C .yt,� s� .aTti ;�' {EATr �,Aliy`CAL:`Cl9L,ATION',, ! .� f.;�, % - v •+ � �� ��� .i is t'e'a ,. P.roposed ,Besi�i�nce LA QUINTS" ,,'.'sDnte• 08/QT` Y. Summer. Dpsn TetnPe�rtu"r ' 112 , �,: �k I Tr-'ansrnission Gain •.Windows; 4 176 SgFt x 0 .65"`x'; 34 x 1 Hr'7 Walls r i 1355 SgFt x 0.05 x 34 x 1 Hr j 2303 Spstuiak C: Floor (slab). 192 LnFt x 0.81 x .34 x '1,. Hr - 5287--68_;Bttah;-u. Floor (raised). ` 0 SgFt x 0.00 x 34 x Hr �.0 00 Btuh D. Ceiling 1542 SgFt x 0.03 x 34 x.1 Hr , rr� t 1532 64,LBtyh �e ;. E. Total Transmission Gain. 1 13012 82 _Btuh`G x -----.-------------------------------- ------------.---- —_� _... Y .�.;. ..a wl p•� � i rte, _ Ii. Infiltration Gain 13930 Cubic Ft. @ one Air Change/Hr. . !� 13930 CuFt x 0.018 x 34 x 1 Hr. , 8525.1 stuh � ____r _-_______------ ---__________ IIITo 21537.98-rBLih'Y� xta]Gain(I+II) fi j syjj __------------------- °tf HEAT LOSS CALCULATION -Proposed Residence= LA QUINTA Winter Design Temperature: 29 w r �'----------------- ------------------------------------------;---------- F I . Transmission Loss. 4x4 r y A. Windows. c. .. 176 GgFt x 0,65 x 41 x 1 -Hr. = 4690.40 Stuh a B. walls. ;A 135 �qFt x, G.05 x 41 z 1 Hr. = 2777.75 Btuh x . C. Floor (slab)- 192 LnFt. x 0.81 x 41 x 1 Hr. = 6376.32 Btuh Floor (raised) - 0 SgFt x 0.00 x 41 x 1 Hr. = 0,00 Btuh D. Cei.lifig . 1502 SqFt x 0.03 x 41 x 1 Hr. = 1847.46 Stuh E. Total Transmission Loss 15691.93 Btuh II. Ivif.i.ltration Loss. 13930 Cubic Ft. @ One Air Change/Hr. 139:s0 C�.aFt x 0 .018 x 41 x 1 Hr . = 10280 .34 Btuh III. Total Loss (I + II) _. tt 25972.27 Stuh 77 �'i � ;. e r e - " y w� "� st,,.�,a'1,: �+`*r, �`�- � k,��,�„,-s � y, « r,y�.ac s � y •� �- ? -a �a -' ��e_ '` # y?;:•� . L .a .tir.. - xF t �t'•..� 1. }.: Y�'f.• `~ ;,� �, s,:,rrw� Ii �. _ ` ,"77.....xr�:.s� �r ,,. 3L x 7 s} -e+ � 4 ��'� �.'�S w'.T�'✓��. '� XI"` r 4 _.� q t � ��S'«r'F'`2 tt �T `�s 5 � " "15?' * �.^ t �. r ;.,F� R ,4bW t 4\`v y a. ✓v43y < t+� 4:' �'# � '�„y phi `';�}F .�.,� �, �'. �.. � ''' '`; � f+ ei” ♦d t� �� - t_°"R£: '� >: a -� �� a i c:� t rt- �`'}, t .,Z S � �i}'K a .� :ir r i /�i•� K' ,� l. � a ;� 1� -1 �� - sir, .. �n C F �� r Y. -s � � 3-}n ''*'�} x,fY, } rr tip F ,. r-• ''�M !" t�,.'" "�s'� � � � .: � .3' S��..� �� �y�. � d y'° 3 `'t . i'� 9 � � ; �. IL HVAC,QUIPMENT,SIj,IN# 7 j'-47 7t T7' .-.f si-Locateori.= LA-'oUINTA �� � 2 ,, p � X© b wf �,} , q' f "� �- t ,}- Y • � '� r r t7 x - +�" -.e r � L �'* "� �a ', kir � � .� ' i 4 DAVE MILLER ��- FjmpledFfor ,r �� r;_. y- — -- --IW f ------------ --- — —� G' F, DESIGN CONDITIONS' f Jutsid`e db 29 F Inside db 70 F Winter'' Design TemperatureD�ff�@reicw2r}. g� y -.;;d ti �. ,outside db 112 F Inside db 78 F _ Summer• Design Temper aturQ,4Differa�cq"� ------------------------------------------ : ------- � F , EQUIPMENT ,SIZING`T, k :}} A. 'Sensible Ventilation Load y M /� ep .. _ �,-Qh'�,y,d4 Off[ x 0.00 Vent. CFM x 34 Summer -��TD + 21.537 f- ��<. Sensible Load for Structure . k s� rye Sum of Ventilation and Structure Loads :' s 21539 9@SB.uF1�s'�� Rating & Temperature Swing Multiplier Equipment Sizing Load Sensible ={24768 68 9tuh B:_. Latent Sizing Load l� 0.68 x 0 .0 Vent . CFM x 0 `gr di , 0 'OOBt , Internal Loads -=230 x 6 number of people + '�380 QQ E3tuh� a.Ttm . } 8525 :16 Bt hit Infiltration Load Equipment Sizing Load - Latent - =9905 16 8tt;uhr a}� ---------_------ ------ ---COOLING-SUMMARY-------- -- -T^- 'y as Total Sensible Gain:24769 Btuh Design TemRerature Swi'ngs'n' Y, Total Latent Gain + 9905 Btuh Normal 3F (X)..4,5F .�iI6ta1 = Sens. + Lat.= 34674 Btuh* $k --------------------------- HEATING SUMMARY b Total Heat Loss for Entire House = 25972 Btuh Ventilation CFM - 0.0 Winter Design TD = 41 F r: Heat Required for Ventilation Air = 1.1 x 0.0 CFM x 41 F= 0 Btuh .Design Heating Load Requirement= 25972 (house )t 0 (vent)= 25972 Btuh q} -w______---- __--_- - --- - ------------------•------------------------------------< MAXIMUM GAS FURNACE OUTPUT 9 CA Energy Commission Stds Sec 2-5352(8) r i 1.3 [Desi.gn heat loss + (10 Btuh)(Area Sq.Ft. )] L 1 3 [ 25972 1 15020 ] = 53290 BtUn *(Note) The loads shown are: only one of the criteria affecting the selection of HVAC equipment. Oth�;r relevant design factors must also be considered. It is the designers vesponsilbility to consider all factors when selecting the HVAC - equipmF.nt . . ♦ � eg , .., •.. ,mss, r+ � � w� � f` -s�` erg • +'# .+CSI,YC"!��?4Ct14..,. 3�'�`Y.+''�i �-y�'k+i. ��Slt �2�•��` _ :' i ,� ZT `jy;`:7" f 'i F " �,f.' - �y=R j„, i ` �i} ,C 6� '�' y 1 `'Ef-�lvt' _ •l ! '!* _ :,.A _ .�.- . yF 'el • • q �Sa 7j 31 yds Vii r^ f "WN k�, f. t, i. + t7i ar +t`a 6: r t 3'� a X''C,'�Y- +<"71�� .. `. ,� ^.�Y .�i" 0 tr.'�', �f p,�'S .'trr ;�. �''.`.+�: r•s t.r, ">*''ri.' '�--- �`` . 7.HE`RMAL''MASS WOkKSHEE7 + 5 >, •. - f ' '� � ��'�� �{S�=-���� ti3' 44 � � �� � n 4t ��,�, - :� �' • <r�ari�:�+. � ��;:�:GkK* ..' 'n f`'t�. �! ��i^�'� xx^fi ` 4i�tAq�a�,at,'� , Dpi e!A��90i r<pro3ect Title: DAVE.t1ILLER%L8 9UINTA,:Y } .° . �r.,,.,, i}i�rt,l-. ��x,,�}y ti#�Y_.-ate i �-- -- _-� 4 .- ?. t tT r P' rt t i '� NTERIOR THERMAL" MASS: u -� + ,41 t - ` .i - � �.., � �. _i �• , �1} '..+.4r ✓t:°y� �D � 1 ;,Use°one}of -the two' following ,options ,for calculating in't'erior;mass>as�explain�d�in �';�rSection' 4!2 of, the Energy Conservation -Manual (ECM). ,- rMethod B'must' be used for+ .,. 1rfi mass elements that have an interior -unit mass 'capacity les_ sa't_ han 1 * '' Method A. Look up the Interior Mass/CFA value from ECM Table 4=7,reprintedon, �he , 'L •R F Y fay iy' t', reverse side of this page. Type 1 mass has a Unit Interior ,Mass Capacity��(UIMC);,„���.,M , greater than or equal to 4.2 (see ECM Tables ,4-8a.,and!4-8b reprinted on At`tachmg'F(�t) " k t Type 2 mass has an UIMC greater than or equal to 1.7 and less than 4*2 MASSx`k��s the mass surface area divided by conditioned floor area (CFA). ' For pass elementsrt` = ,th-rp ti'exposed on both (two) sides to conditioned space, enter -the 'area of only cone side, to".: l . Al" calculate the percentage. Mass z. Type 1 Mass. Area : 0385.0 _ 26 + Type 2 Mass Area: 1117.0 74 Interior• Mass/GFA from Table,4 7�2 ;.f ttiod B, Calculate the Interior Mass/CFA value using the work "sheet space below" " ►+' o.Q:kmuP the Unit Interior Mass Capacity (UIMC) for each interior mass surface i'n�ECM3 �i ;' r _T-abies 4-8a, 4-8b and 4-9 reprinted on the Attachment. Include the ,interior ` surfaces of exterior mass walls. For interior mass walls exposed,on,both ONO). ! , s'. asides --to -conditioned space, enter the surface area of only one side.' Include fh'e # � alls as ex' lained in Section 4.2of theECM ��'�"`�jr r ' si.de surface. .of exterior mass w P y+ Unit Interior Interior r Description Mass Area x Mass Capacity = Mass Capacity ------------- ------------- .. ---------------- _---_---- t (Intent,ionally .left blank) _ .:, Total / CFA - Interior " i Mass/CFA ?, t------------------- --------------------------- .EXTERIOR WALL THERMAL MASS; Calculate the Exterior wall Mass of all exterior walls. Look up the Exterior Mass i + s Factor for each opaque wall. element from ECM Table 4-9 reprinted on the Attachment,: Only exterior mass wall. surfaces ma/ be included in this calculation. r Opaquc Exterior Description Wall Area x Mass Factor = (Intentionally left blaTik) Total / Total Opaque = Exterior Wall Area Wall Mass in'� rt '.. t^.- ,�iP� l -� ;'- 1r", :'h - ti ••": �� i�� ,' --:' �+ %-- � �t.", -.• tf-'* t s.'+ �,r",t .��.� °lljAt�pTQQY KEASURES CHECKLIST.' RESIDENTIAL :DAVE MILLER/LO OUINTA 08/01/90" '# +� * > +' �. � « •t '` Mrlr- ...__---•--_----•_. --_ _ _ ------ 'r--r-s---- -----.. - ' _ .r�.rt.yy,. ry __ _-n w.. rw-Nr....,p.�w..w ;•. �.�. ..r - -- - -ec J _ r `�,;►o�e: lowrise residential buildings subject to the Stindards oust contain thpse i,easures regardless of the complibmtpproath +�.: ' used. items marked with an asterisk (i) may be superseded br lore stringent compliance requirements listed ce;tttIr'�21, {�4•A: cateof Compliance., When this checklist is incotporated into .tie permit documents, the features ppted glial bconSid �.. 3 ` by all parties as binding minimum coeponentperformanci specification fer: the sAndetori. easu►es=a iether'ther ori 048, sfio m:.•, #� elsewhete in the docuaents o,- on this checklist only, .Y '> ,_ ,� s 1, ' +. t •- -----------_- r r . �r -------- -------- -------- _ 4w*a.., r.'ra-*+• ' tt;r ; DESIGNER ;£MFMIEMT DESCRIPTION - _ �. - - - !x:,1 "'+'�+•-------------------------------------------------'•-_--__---_--------------- -------------r�•i r.rrr..rf» ►r tea.+'►e s 8yildimy Envelope Measures } R38 •2-5352(a): Minimum ceiling insulation R-19 weighted average. n4 + 2-5352(b): Loose fill insulation manufacturer's labeled R -Value. s2 -5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to - exterior mass walls). 2=5352(k): slab edge insulation -water absorption rate no greater than,0.3%, water vapor transmission rate no greater than 2.0 perm/inch. •{ ` r. YES, t� 2-5311: Insulation specified or installed meets California Energy Commission (CEC)_quality standards. Indicate type and form, FIBERGLASS--BATiS rr YES ,%-, ._ YES Ft 2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16 only.,c xs# ` 2-53i7:-infiltration/Exfiltration Controls ; a. boars and windows between conditioned and unconditioned spaces designed to limit air ,�w �y. `' 4 ,leakage. -YES i 1 t � , Doprs a,id windows certified. � � �-�, YES ti c�``^'�Doors 11-andows weatherstripped; all joints and penetrations caulked and sealed. YES r �; x •'.2-5352(e)""�0=a1 infiltration barrier installed to comply with 2 -5351 -meets CEC quality ; ' _ fi ,rYi``• standards. 2-5352(d): Installation.of Fireplaces. {; i; ..r 1. Masonry and fy-built fireplaces have: a, Tiyht fitlimg� closeable metal or glass door. I J { � .;- 5� r k b..Oytside air intake with damper and control. f�:; til ` c. FIue-damptr-and control. ' 2. No -Continuous 4urning gas pilots allowed. s3 a HVAC and.Plu#i�ng Systea; MeasuresYES 2-535iti(_g) 4'1-5303: Space conditioning equipment sizing: attach calculations. YES µ , 2^,452(h) and 2=5313: Setback thermostat on all applicable heating systems. YES :2-5316(a): Ducts constructed, installed and insulated per Chapter 10, 1976 UMC. s{ 1!_ YES 2-5316(b): Exhaust systems have damper controls. YES f 2-5314(c): Gas-fired space heating equipment has Intermittent ignition devices. . 2-31`4::HVAC equipment, water heaters, showerheads and faucets certified by the CEC. YES 2-5352(i): Water heater insulation blanket (R-12 or greater) for storage and backup tanks -, for solar water heating systems (first 5 feet of pipes closest to tank insulated (R-3 or greater). YES 2-5312(Exception 1:):. Pipe insulation on steam and steam condensate return S recirculating piping. _ F 2-5318(d): Swimmi=ng Pool 'heating. 1. System has: a. on/off switch on heater. b. Weatherproof instruction plate on heater. r c. Plumbed to allow for solar. s 2. 75 oercent thermal efficiency. 3. Pool cover. 4, Time clock. 5. Directional water inlet. 4 Lighting and Appliance Measures : 2-5352(j): Lighting -25 ,omens/watt or greater for general lighting in kitchens and bathrooms. YES . . ... . _. 1. 1 _- 1_..t--- rrc J1, `a 77 "4 ,, ry^ {�fy� ��Y4�1SY "4-,, j Nt —�y, 5':F" rie�Z.-;�•`w' 1?oi Y'•" f- `Y M r- . + Cly h^�-'i' frY '1{. 4 ' ], f� A�MIL`�,R/L^A� QUINTAL DESCRIPTION OF Z�ISTAIL-ATION'_ E 3i "1 i } _ ; ij►`s =� Mdterlal Bra d. me .� t i ° x� n Thickness (inches)_ Thermal Resistance (R -Value) :EXTERIOR WALL_ k"._ t* Material Brand Name t.5 rT-hickness (inches) a . ., Batt or Blanket Type Brand Name Thickness (inches) Thermal Resistance (R' Value + ;- "� Loose Fill Type Brand Name` ' Contractor's min instld wt/fta lb Minimum thickness' x inches _ w�, k ', i s O # / "2KF l RAISED FLOOR f'f ._ . )P Material Brand Name 1:hickness (inches) ( ). S 4 Thermal Resistance R -Value " rl SLAB FLOOR Material Brand Name' Thickness (inches) _ Thermal Resistance ('R -Value) Width (inches) t` ' WDATION •WALL ., Material Brand Name Thickness (inches)_ _ Thermal Resistance (R -Value) � c 1 DECLARATION L hereby certify that the above insulation was installed in the building,at,the above- location bovelocation in conformance with the current. building Energy Efficiency Standards for new reRidPntial hiiildinas contained in Title 24 of the California Administrative Code. General Contractor (Builder) Signature and Title Sub -Contractor (Insulation Installer) -S y. License Number ;a Date t License Number Signature and Title Date t "r r. #� 5 -ZUO Indian Hills Box Mountain Center,,CA 1-800-262-9966 1 , f a . AUGUST 1 , 1990 --TO: DAVE MILLER LA QUIN TA, CALIFORNIA INVOICE •k 1 set CEC Compliance Reports, 1502 Thank you, W. J. Finnel.l 34F 92361 r •- + err Lic ,473969 13 . Ft � A ;>s , .� tit r •�� f Ftp Building = $`50:0Q { �P ' ,r i � 7 + ? ENERGY CONSULTING GROUP '. ><.tt" Indian Hills Box Mountain Center,,CA 1-800-262-9966 1 , f a . AUGUST 1 , 1990 --TO: DAVE MILLER LA QUIN TA, CALIFORNIA INVOICE •k 1 set CEC Compliance Reports, 1502 Thank you, W. J. Finnel.l 34F 92361 r •- + err Lic ,473969 13 . Ft � A ;>s , .� tit r •�� f Ftp Building = $`50:0Q { �P ' ,r i � 7 i." 1.4 r i Indian Hills Box Mountain Center,,CA 1-800-262-9966 1 , f a . AUGUST 1 , 1990 --TO: DAVE MILLER LA QUIN TA, CALIFORNIA INVOICE •k 1 set CEC Compliance Reports, 1502 Thank you, W. J. Finnel.l 34F 92361 r •- + err Lic ,473969 13 . Ft � A ;>s , .� tit r •�� f Ftp Building = $`50:0Q { �P ' ,r 44 r kt< .i'+'�{Y'.'�s ,•S..s ��', >• - �� 5� �. s 4�t�.�l��e"fi•i+� �1+. ,, *�� 5 � ��� Vis"' �Y, i x�,.' Y. �" *` J �•�' '�„�a� ��1'_ , y����s i�;��, �"' .qs t'3" X+v+�+ }}.. Al x•. . 9 fM1 .. ,,.'ks S'. 'l �" ni art's^ .�' Tom' rc, SLK. a "'"- f Y 'L, .z d'.�•'µr ft `' d,..t ,,,yyy �.r`< ,µ "�",. x"'41 .t�. -Is . ,• ys a -5� '� T.'x 2,4 �.. xv••• }+w ``4F•,� y R , ► P.OINT:.SYST.EM? SUMMAf�Y a Clba mate,:7_one +x� "'A ,� ' 7,� .�y ' i �i"r`t+_ v 'F .� r f f • ti!,�ar.� �'.�'� �4- ��i+-�rf.;+ f 6'r `} t�� - 'r ^' ii'.. 1+� .z Z ' a i�C' +i a"+!S•i+'a�C .} ._.r_ ek- �.'� �rty,t t - T.�:.. x -� ,tom' •_ ,p '•' i+ a i i1 t4 + `pM1,°�DAVE,- __qrtY..�- 0�• 8/ap�- /9,.rMILLERject'Tit1eOate 14 1w v`11I.Oi�G DATA'. • ? ;Glass Areae %Glass; ' SgFt Condit oned Floor Area- 1502- `'. j- �.Nor"rtfir 70 a , �� . rr'. , "k, dumber of stories. 1 East 40 1 -2 6�;. ti r a ` South s� .. h Slab/Raised Floor SLAB ,3{20., 1yw'r Single Family Detached: X West, w *.33'''�}�42O #�Sin le°. rami ly Attached: Skylfight 00 : a d� ?, ,- Totals: ^t � g ,= Multi-� mily 176;X' Adci,itio,n Alone Ex'!stirig Building ting Plus Addition �--------------------------- -- ---------------- SCARE CARD- Measures Point tt''�9t4 {. 1. Ceiling Insulation R: 38, or U: 0 .��YN = Wall Insulation R: 19y or U, 0 .. .� ,,•,.� ,r . ` �'3•. Raised Floor Insulation R: 0 or U= 0 �c"{' R 0 o r U: 0 1, ••, -;' Sla Edge Insulation ITTfiltration. Standard 0 •;a �`� 6! Glass Heat Loss. Type U -Value %Glass a ' �;.• DOUBLE 0 .65 - 11.72 5 ,_ •, s .. Sum 1-6:- L�- ` 7. Shading` (Shade Open) %Glass x SC = Eff %Glass• a North 4.66 •0.77 3.59 * b'. East 2.66 0.77 • 2.05 0 ` F. :c.. South 2 .20 0.77 1.69 0 *• 'k ; ;,� }` d. West • 2.20 0.77 1.69 0 4 '� r e. Skylight • 0.00 0.00 0.00 0 "zl ��. 8. Shading ( Shade Closed) %Glass x SC = Eff %Glass f' t - 4 .66 • '0 .66 3.'.08 -1 '` • < a. North " b'. East = 2.66 = '0.66 1.76 : -2 t 1 C. South 2.20 = 0.29 0.64 : 3 ' d. West 2.20 = 0.29 0.64 = 3 { e. Skylight 0.00 0.00 0.00 0 9. Interior Thermal Mass = 2.30 ` 10. Exterior Wall Mass = 0.00 . 0 ' Sum 7-10: 1 i. 11. Heating System. (SE or HSPF x Duct Eff = Eff SE) 0.72 x . 0.78 = 0.5616 0,1 Zonal Control' NO 0 12. Cooling System. (SEER x Duct Eff = Eff SEER) 9.00 x 0.74 6.66 -5 Zonal Control: NO 0 .. 13. Water Heating. Type SE Credit: 0 0 POINT TOTAL : 1 } CERTIFICATE OF COMPLIANCE. RESIDENTIAL` (Page 1 of 2) CF -1R ---------------------------------------------------------------------- Project --- -Project Title= DAVE MILLER Date= 08/01/90 Project Address= LA QUINTA Documentation Author. Energy Consulting Group, 1-800-262-9966 Compliance Method. Point System. Climate zone: 15 ----------------------------------------------------------------------- Enforcement Agency Use Only. Building permit # Checked by/date. GENERAL INFORMATION 1 Total Conditioned Floor Area. 1502 SgFt. Building Type.- SINGLE FAMILY DETACHED } Front Entry Orientation. EAST Number of Dwelling Units. Floor Construction Type. SLAB Infiltration Control. STANDARD ------------------------------------------------------------------------ BUILDING SHELL INSULATION Component Type Wall Wall Roof Roof Floor. F:'1•oor Slab Edge Insulation R -Value ------------------- 19 38 0 0 Location/Comments ------------------ TYPICAL, FIBERGLASS BATTS TYPICAL, FIBERGLASS BATTS �._......""9'y------------------------------------_..-------._-_----_------ GLAZING Glazing ;Area Glass Type Interior Exterior Overhang Frame Type Orj.eptat,i�on �+ (sf) Single,etc. Blinds sh screen --------- yes/n,o -- ----- - metal/wood ---------- AYoi t E 40 DOUBLE. NONE NO NO METAL Front Left S X33 DOUBLE LIGHT NO NO METAL �:ef t VENETIAN Rear W 33 DOUBLE LIGHT NO NO METAL Rear VENETIAN Right N 70 DOUBLE NONE NO NO METAL Right Skylgt 0 Skylgt THERMAL MASS I Type/Covering Area Thickness Location/Description (slab, exposed ) ( sf ) (inches) (kitchen, bath, etc.) TYPE 1 TILE 0385 3.5 KITCHEN, ENTRY, BATHS & LAUNDRY TYPE 2 CARPET 1207 3.5 REST OF HOUSE CERTIFICATE OF ---------------.--------------------------------------------------------- COMPLIANCE. RESIDENTIAL (Page 2 of 2) 3 CF -1k Project Title: ----------------------------------------------------------------------- DAVE MILLER Date: 08/01/90 HVAC SYSTEMS Maximum Furnace Heating Output: 53290 Btuh. HOT WATER SYSTEMS. Tank Manufacturer/Model# System Type Capacity (or approved equal) . Special Feature(s) STORAGE ELECTRIC 40 R-12 Externa.l.Blanket on Storage Tank (Yes or No) YES ------------------------------------------------------------------------- SPECIAL FEATURES/REMARKS= HEAT RECOVERY UNIT INSTALLED ON WATER HEATER. LIGHT VENETIAN'BLINDS IN SOUTH AND WEST WINDOWS. ---------------- -------------------------------------------------------- COMPLIANCE STATEMENT. This certificate of compliance lists the building features and perform- ance specifications needed to comply with Title 24, Chapter 2-53 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Admin- istrative code. This certificate has been. signed by the individual wi,t.h overall,design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of'the building. When this,'certificate-of compliance is Submitted for a single building plan to be'built in multiple orienta- ti.ons, all building conservation features which vary are indicated in they>Sp°.eeial>;Fe_atures/Remarks section. 6E;IGNER , (Sig—nature) BUILDING OWNER. Q�, (date) (signature) DOCUMENTATION AUTHOR: W. J. FINNELL #473969 ENERGY CONSULTING GROUP Indian Hills Box 34F Mountain Center, CA 92361 1-800-262-9966 (sign'ature)` 08/01/90 ENFORCEMENT Name Title Agency Telephone— AGENCY. ( date ) ( signature/stamp ) (date) Minimum Duct Type(furnace, Efficiency Location Duct Output Mfgr/Model# a./c,, hp, etc.) (SE ,SEER,HSPF )( a.ttic,etc ) R -Value (Btuh) (or apvd equal) FURNACE 0.72 ATTIC 2.1 AIR CONDITIONER 9.00 ATTIC 2.1 Maximum Furnace Heating Output: 53290 Btuh. HOT WATER SYSTEMS. Tank Manufacturer/Model# System Type Capacity (or approved equal) . Special Feature(s) STORAGE ELECTRIC 40 R-12 Externa.l.Blanket on Storage Tank (Yes or No) YES ------------------------------------------------------------------------- SPECIAL FEATURES/REMARKS= HEAT RECOVERY UNIT INSTALLED ON WATER HEATER. LIGHT VENETIAN'BLINDS IN SOUTH AND WEST WINDOWS. ---------------- -------------------------------------------------------- COMPLIANCE STATEMENT. This certificate of compliance lists the building features and perform- ance specifications needed to comply with Title 24, Chapter 2-53 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Admin- istrative code. This certificate has been. signed by the individual wi,t.h overall,design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of'the building. When this,'certificate-of compliance is Submitted for a single building plan to be'built in multiple orienta- ti.ons, all building conservation features which vary are indicated in they>Sp°.eeial>;Fe_atures/Remarks section. 6E;IGNER , (Sig—nature) BUILDING OWNER. Q�, (date) (signature) DOCUMENTATION AUTHOR: W. J. FINNELL #473969 ENERGY CONSULTING GROUP Indian Hills Box 34F Mountain Center, CA 92361 1-800-262-9966 (sign'ature)` 08/01/90 ENFORCEMENT Name Title Agency Telephone— AGENCY. ( date ) ( signature/stamp ) (date) 0 i t s k � s 1f' HEATING, VENTILATING a AIR CONDITIONING j; DESIGN DATA !! r 1. LOCATION LA QUINTA 2, DATE 08/01/90 3. COMPILED FOR DAVE MILLER t 1 4. WINTER DESIGN TEMP 29 r i } 5. SUMMER DESIGN TEMP 1,12 l `6. CONDITIONED SQ FT 1502 i 7. .. SQ FT 176 U -VALUE 0.65 ,W.INDOW S. WALL SQ FT 1.355 U -VALUE 0.05 9. SLAB FLOOR LIN FT 192 U -VALUE 0.81 10. tkAISfD FLOOR SQ FT 0 U -VALUE 0.00 i 11. CEILING SO FT 1502 U -VALUE 0.03 12. CONDITIONED CU FT 13930 1"3. VENTILATION CFM 0.00 . 14. !RS MULTIPLIER 1.15 15. GRAINS DIFF 0 16. NO. OCCUPANTS 6 0 HEAT GAIN CALCULATION Proposed Residence: LA QUINTA Date: 08/01/90 Summer Design Temperature: 112 ------------------------------------------------------------------------------i I. Transmission Gain_ A. Windows. 176 SgFt x 0.65 x 34 x"M 1 Hr. = 3889.60 Btuh B. Walls, 1355 SgFt x 0.05 x 34 x 1 Hr. = 2303.50 Btuh C. Floor (slab). 192 LnFt x 0.81 x 34 x 1 Hr. = 5287.68 Btuh Floor, (raised). 0 SgFt x 0.00 x 34 x 1 Hr. = 0.00 Btuh D. Ceiling, 1502 SgFt x 0.03 i x 34 x 1 Hr. = 1532.04 Btuh E. Total Transmission Gain. 13012.82 Stuh -------------------------------------------------------------------------------- II. Infiltration Gain. 13930 Cubic Ft. @ one Air Change/Hr. 13930 CuFt x 0.018 x 34 x 1 Hr. = 8525.16 Btuh -----------------=---------------------------------------------------------------- III . Tota]. Gain ( I + II ) 21537.98 Btuh HEAT LOSS CALCULATION Proposed Residence: LA QUINTA Winter Design Temperature: 29 6 I. Transmission Loss. -� A. Windows. 176 SgFt x 0.65 x 41 x 1 -Hr. = 4690.40 Btuh B. Wal`ls . 1355 SgFt x. 0.05 x 41 x 1 Hr. = 2777.75 Btuh C. Floor (slab). ' 192 LnFt x 0.81 x 41 x 1 Hr. = 6376.32 Btuh Flbor (raised). 0 SgFt x 0.00 x 41 x 1 Hr. = 0.00 Btuh D. Ceiling. 1502 SgFt x 0.03 x 41 x 1 Hr. = 1847.46 Btuh E. Total Transmission Loss 15691.93 Btuh II. Infiltration Loss. 13930 Cubic Ft. @ One Air Change/Hr. 13930 CuFt x 0.018 x 41 x 1 Hr_ = 10280.34 Btuh III. Total Loss (I + 11) 25972.27 Btuh t� V HVAC EQUIPMENT SIZING ------------------------------------------------------ -- -- _ ---- - - Design LocationLAQUINTA Date: 08/01/90 Compiled for: DAVE MILLER ------------------------------------------------------------ i ---- ---- DESIGN CONDITIONS c1TNTER Outside db 29 F Inside db 70 F Winter Design Temperature Difference 41 F SUMMER Outside db 112 F Inside db 78 F Summer Design Temperature Difference 34 F --------------------------- EQUIPMENT SIZING LOAD A. Sensible Ventilation Load 1.1 x 0.00 Vent. CFM x 34 Summer TD - 0.00 Btuh Sensible Load for Structure + 21537.98 Btuh Sum of Ventilation and Structure Loads = 21537.98 Btuh Rating & Temperature Swing Multiplier x 1.15 Btuh Equipment Sizing Load - Sensible = 24768.68 Btuh B. Latent Sizing Load 0.68 x 0.0 Vent. CFM x 0 �gr. diff. = 0.00 Btuh Internal Loads = 230 x 6 number of people + 1380.00 Btuh Infi-ltration Load + 8525.16 Btuh Equipment Sizing Load -- Latent - 9905.16 Stuh. COOLING SUMMARY Total Sensible Gain: 24769 Btuh Design Temperature Swings Total Latent Gain + 9905 Btuh Normal 3F (X) 4.5F ( ) �,Taotal = Sens. + Lat.= 34674 Btuh* -------------- -__._________.___ HEATING SUMMARY Total Heat Loss for Entire House - 25972 Btuh Ventilation CFM- 0.0 Winter Design TD = 41 F Heat Required for Ventilation Air = 1.1 x 0.0 CFM x 41 F= 0 Btuh ,Design Heating Load Requirement= 25972 (house)+ 0 (vent)= 25972 Btuh* --------------------------- '------------------------------------------ MAXIMUM GAS FURNACE OUTPUT CA Energy Commission Stds Sec 2-5352(g) 1 .3 [Design heat loss + ( 10 Btuh )(Area Sq.Ft. )] 1.3 I 25972 + 15020 ] = 53290 Btuh *(Note) The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors must also be considered. It is the designers responsibility to consider all factors when selecting the HVAC equipment. ^4 THERMAL MASS WORKSHEET WS -1R Project Title: -DAVE MILLER/LQ QUINTA Date: 08/01/90 INTERIOR THERMAL MASS: Use one of the two following options for calculating interior mass as explained in Section 4.2 of the Energy Conservation Manual (ECM). Method B must be used for mass elements that have an interior unit mass capacity less than 1.7. Method A: Look up the Interior Mass/CFA value from ECM Table 4-7 reprinted on the reverse side of this page. Type 1 mass has a Unit Interior Mass Capacity (UIMC) greater than or equal to 4.2 (see ECM Tables 4-8a and 4-8b reprinted on Attachment). Type 2 mass has an UIMC greater than or equal to 1.7 and less than 4.2. Mass % is the mass surface area divided by conditioned floor area (CFA). For mass elements exposed on both (two) sides to conditioned space, enter the area of only one side to calculate the percentage. Mass Type 1 Mass Area: 0385.0 = 26 Type 2 Mass Area: 1117.0 = 74 Interior Mass/CFA from Table 4.7 = 2.3 -":Me'thod B: Calculate the Interior Mass/CFA value using the worksheet space below. -Look-up tie Unit Interior Mass Capacity (UIMC) for each interior mass surface in ECM _T.i_bles 4-8a, 4,-8b and 4-9 reprinted on the Attachment. Include the interior sdrfaces of exterior mass walls. For interior mass walls exposed on both (two) -sides to condition:e.d space, enter the surface area of only one side. Include the =inside sur,f,aces'.of exterior mass walls as explained in Section 4.2 of the ECM. Unit Interior Interior Description Mass Area x Mass Capacity = Mass Capacity (Intentionally left blank) Total / CFA = Interior Mass/CFA EXTERIOR WALL THERMAL MASS: Calculate the Exterior Wall Mass of all exterior walls. Look up the Exterior Mass Factor for each opaque wall. element from ECM Table 4-9 reprinted on the Attachment. Only exterior mass wall surfaces may be included in this calculation. Opaque Exterior Description Wall Area x Mass Factor = (Intentionally left blank) Total. / Total Opaque = Exterior Wall Area Wall Mass MANDATORY MEASURES CHECKLIST: RESIDENTIAL DAVE MILLER/LO CUINTA 08/01/90 2-5352(8) and 2-5303: Space conditioning equipment sizing: attach calculations. MF -IR 2-5352(h) and 2-5313: Setback thermostat on all applicable heating, systems. YES ------------------------------------------------------------------------------------------------------------------------------------ Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (s) may be superseded by more stringent compliance requirements listed on the Certifi- cate of Compliance. When this checklist is incorporated into the permit documents, 'the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. piping. ------------------------------------------------------------------------------------------------------------------------------------ DESCRIPTION DESIGNER - ENFORCEMENT ----------------------------------------------------------------------------------------------------------------------------------- Building Envelope Measures a. On/off switch on heater. x2 -5352(a): Minimum ceiling insulation R-19 weighted average. R38 2-5352(b): Loose fill insulation manufacturer's labeled R -Value. 2. 75 percent thermal efficiency. s2 -5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to 3. Pool cover. exterior mass walls). R19 5. Directional water inlet. 2-5352(k): slab edge insulation -water absorption rate no greater than 0.32, water vapor transmission rate no greater than 2.0 perm/inch. YES 2-5311: Insulation specified or installed meets California Energy Commission (CEC) quality standards. Indicate type and form. FIBERGLASS--BATTS YES 2-:5352,(f);: Vapor barriers mandatory in Climate tones 14 and 16 only. YES 2-5,317:•Infiltration/Exfiltration Controls a. boors and windows between conditioned and unconditioned spaces designed to limit air leakage. YES _b. Doors and windows cer't-ified. YES -c:' 06 -6r --s Ad, :wi.ndows weatherstripped; all joints and penetrations caulked and sealed. YES 2-5352(e)Kpial-'infiltration barrier installed to comply with 2-5351 meets CEC quality standards. 2-5352(d): Installation:of Fireplaces. 1. Masonry and faetgr,y-built fireplaces have: a. Tight fitting, closeable metal or glass door. b. Outside air intake with damper and control. c,. Flue damper and control. 2. No.continuous burning'gas pilots allowed. - HVAC and Plumbing System' Measures 2-5352(8) and 2-5303: Space conditioning equipment sizing: attach calculations. YES 2-5352(h) and 2-5313: Setback thermostat on all applicable heating, systems. YES *2-5316(a): Ducts constructed, installed and insulated per Chapter 10, 1976 UMC. YES 2-5316(b): Exhaust systems have damper controls. YES 2-5314(c): Gas-fired space heating equipment"has intermittent ignition devices. YES 2-5,314: HVAC, equipment,'water heaters, showerheads and faucets certified by the CEC. YES 2-5352(i): Water heater insulation blanket (R-12 or greater) for storage and backup tanks for solar water heating systems (first 5 feet of pipes closest to tank insulated (R-3 or greater). YES 2-5312(Exception I): Pipe insulation on steam and steam condensate return & recirculating piping. 2-5318(d): Swimming Pool Heating. 1. System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater, c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clock. 5. Directional water inlet. Lighting and Appliance -Measures 2-5352(j): lighting -25 lumens/watt or greater for general lighti`hg in kitchens and bathrooms. YES 2-5314(c): Gas fired appliances equipped with intermittent ignition devices. YES � , INSULATION CERTIFICATE ' ' DAVE MILLER/LA QUINTA � ' � . � Date: 08/01y90 _ DESCRIPTION OF NSTALLATrON ' ROOF �Material Brand Name Thickness (inches) Thermal Resistance (R -Value) . . � EXTERIOR WALL ^ Material Brand Name Thickness (inches) CEILING Batt or Blanket Type Brand Name Thickness (inoheo) Thermal Resistance (R -Value) . , Loose Fill Type Brand Name Contractor's min inatld wt/ftrlb ' Minimum thickness inches RAISED FLOOR . ' . � �MA..terial ' Brand Name Thickness (inches') Thermal Resistance (R -Value) ' SLAB FLOOR . Material Brand Name Thickness (inches) Thermal Resistance (R -Value) Width (inche�) ^ OATION`WALL � * Material Brand Name Thickness (inches)— Thermal Resistance (R -Value) ` DECLARATION � hereby certify that the above insulation o installed in the building at the above location in conformance with the current building Energy Efficiency Standards for new reaidential buildings contained in Title 24 of the California Administrative Code. ` K General Contractor (Builder) License Number M � Signature and Title Sub -Contractor (Insulation,Installer) ' . � =iyvu,u/e and Title \� U Dat e. License Number Date