Loading...
13-0094 (SFDf P.O. BOX 1504 ' f, 78-495 CALLE TAMPICO . LA QUINTA, CALIFORNIA 92253. BUILDING & SAFETY DEPARTMENT BUILDING PERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/22/13 Application Number: 13-00000094 - Owner: Property Address: 53725 AVENIDA VALLEJO STOCKDALE APN: 774-122-026-12 -000000- 50-855 WASHINGTON ST C-217 Application description: DWELLING - SINGLE FAMILY DETACHED LA QUINTA, CA 92253 Property Zoning: COVE RESIDENTIAL Application valuation: 177855 r;r-lWar�;.F Contractor:Applicant: Architect or Engineer: CT BUILDERS INC 2613 3194 AIRPORT LOOP 26 STE C2 COSTA MESA, CA 92626 (ZUII�TA (714)327-1710 rll ffl Lic. No.: OOR SQUARE FOOT Lic. No.: 974805 ----------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury,that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Profession Is Code, and my License is in full force and effect. License Class: B L'c R Ko.: 974805 � Data: V v-3Contractor: L/ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.): (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: N 01 Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of conse6t to self -insure for workers' compensation, as provided , for by Section.3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any (/ 4 person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become su 'act to the workers' compensation provisions of Section 370QQ0 of the LaboroCodel fort it 1�y withthoseprov'sions. Dater � /5Applican-WANING: FAILURE TO SECURE ORKERSCOMPENSATION COVERAGE IS UNLAWFUL, AND SHALL - SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives off this ounty t , meerr upon the above-mentioned party for in coon s (Dat -2&!e— ignature (Applicant or<Agent): w Application Number . . . . 13-00000094 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . .. 828.50 Plan Check Fee 538.53 Issue Date ;Valuation :' . . . 153916 Expiration Date 1/04/14 . Qty Unit Charge Per Extension BASE FEE 639.50 54..00 3.5000 THOU BLDG 100,001•=500,000'- - '189.00. - ---------------------------------------------------------------------------- Permit . ELEC-NEW RESIDENTIAL Additional'desc . Permit Fee 254.40 Plan Check Fee 63.60 Issue Date . . . Valuation . . . 0 Expiration Date 1/04/14. Qty Unit Charge Per Extension , BASE FEE 15.00 2640.00 .0300 ELEC NEW RES - MULTI FAMILY 79.20 " 2640.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 92.40 2640.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 52.80 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee 135.00 Plan Check Fee .00 Issue Date Valuation 0 Expiration Date 1/04/14 Qty Unit Charge Per Extension BASE FEE 117.00. 2.00 9.0000 --------------------------------------------- THOU GRADING 1001-10,000 -------------------------------- 18.00 ' Permit . . . MECHANICAL Additional desc . Permit Fee .77.00 Plan Check Fee 19.25 Issue Date . . . . Valuation 0 Expiration Date 1/04/14 . Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K-. 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K.BTU 18.00 3.00 6.5000 EA MECH VENT FAN 19.50 LQPERmrr LQPERMIT Application Number 13-00000094 Permit . . . . MECHANICAL Qty Unit Charge Per Extension 1.00 6.5000 EA ---------------------------------------------------------------------------- MECH EXHAUST HOOD 6.50-' Permit . . . PLUMBING Additional desc . Permit Fee . . . . 234.75 Plan Check Fee 58.69 Issue.Date _ Valuation . . ... 0 Expiration Date 1/04/14 Qty Unit Charge Per- Extension - BASE FEE 15.00 21.00 6.0000 EA PLB FIXTURE 126.00 1.00 15.0000 -EA . PLB BUILDING SEWER 15.00' 6:00 6.0000 EA PLB ROOF DRAIN 36.00 2.00 7.5000 EA,: PLB WATER HEATER/VENT- 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 .1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00. 1.00 7500 EA PLB GAS PIPE >=5 .75 1.00 15.0000 EA PLB GAS METER., 15.00 ----- - --- ------------------------------------------ Sp Special Notes and Comments ------------------------ 2640 SQ._ FT. SFD WITH 818 SQ. FT. PATIO AND 539 SQ. FT. GARAGE.PER 2010 CALIF BUILDING CODES. June 26, 2013 10:52:18 -AM JJOHNSON. this per does,not include pool.spa or block walls. July 31, 2013 8:45:42 AM jjohnson. Other Fees . . BLDG STDS ADMIN (SB1473) 7.00 DIF COMMUNITY CENTERS -RES 104.00 DIF CIVIC CENTER - RES 942.00 ENERGY REVIEW FEE 53.85 DIF FIRE PROTECTION -RES 433.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 344.00 MULTI -SPECIES (MSHCP) FEE 531'.00 DIF PARK MAINT FAC - RES 40.00 DIF PARKS/REC - RES 2048.00 COVE PRECISE PLAN FEE 100.00 STRONG MOTION (SMI) - RES 17.02 TUMF: RESIDENTIAL 1837.44 DIF STREET MAINT FAC -RES 116.00. DIF TRANSPORTATION - RES 2842.00 Fee summary. Charged' Paid Credited Due 'Application Number . . . 13-00000094 Permit Fee Total 1529.65. .00 .00 1529.65 Plan Check Total 680.07 500.00 .00 180.07 Other Fee Total* 9430.31 .00 ..00 9430.31 Grand Total 11640.03 500.00 11140.03 .00 s Ei1VI;ANDS/iC CFM OF Ttn�v Return check to requestor Mail check Name / Title of person requesting check �mcmA A-o�-C- Depan,pient individual is associated with: Check payable to: r Nvic Amount: $ `1 0 0 (Name) ( (Vendor �No.) /' Account Number: (Address) oo Project Number: �r Check description and invoice number: 14- 1.4 P77 Q 4 u Signature: (DepartmentHead) (Date) k }}`APPROVEb FOR�PAA' ENT µ = (Finance Depar6hent Use Ohl i ttr L "J.�f Z,sh," ,,ACCOUNTNOr fR tui l "jDESCRI�PpTN� IO:' 'A* + l W«.r�'� ?7ftss .:.,+�'2T.f F' •: . 4 ?:_si " - ;.Y ..gyp`. �• - y -;r - .:.,. lTitv/ 4.4 a" Ak P.O. BOX 1504 APPLICATION ONLY Building %CLTAMPICO Address *� IN ,CALIFORNIA 92253 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT FINAL DATE Issued by: Validated by: Validation: YELLOW = APPLICANT Front Setback from Center Rear Setback from Rear Prop. Line Side Street Setback from Center Line de Setback from Property Line INSPECTOR Date Permit PINK = FINANCE BUILDING: TYPE CONST. A.Number P. 1 OCC. GRP. 2Zk L If Address Add Legal Description Project Description Z� ity Zip Tel. Contractor �� Address City Zip Tel. Sq. Ft. j/�,Q,f� Size C_jC lJ No. No. Dw. Stories Units State Lic. & Classif. City Lic. # Arch., Engr.,� �� New Add ❑ Alter ❑ Repair ❑ Demolition 11Designer V Addre � Tel. <2D 7ko .S'70,/07 i Cjtty - �A Zi State Lic. # LICENSED CONTRACTOR'S 15ECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION Estimated Valuation 4 I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500). z - PERMIT AMOUNT Plan Chk. Dep. &,PDivision $Teo . ._, 1 ;p gat Plan Chk. Bal. ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). 01, as owner of theroe p p rty, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Const. Mech. Electrical Plumbing - - S.M.I. Grading Driveway Enc. ------- Date-Owner Infrastructure WORKER'S COMPENSATION DECLARATION It 1 hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. U9013 CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. TOTAL REMARKS r n ct JeN u I T ' e11r1 ANCE DEP Date Owner NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. ZONE: BY: Minimum Setback Distances: CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT FINAL DATE Issued by: Validated by: Validation: YELLOW = APPLICANT Front Setback from Center Rear Setback from Rear Prop. Line Side Street Setback from Center Line de Setback from Property Line INSPECTOR Date Permit PINK = FINANCE CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Date 7/9/13 La Quinta, CA 92253 No. 31715 (760) 771-8515 Owner Ronald & Charlie Stockdale APN # Address 50855 Washington St. C-217 Jurisdiction City La Quinta Zip Permit # Tract # No. of Units Type Single Family Residence Lot # No. Street Unit 1 53725 Avenida Vallejo Unit 2 Unit 3 Unit 4 Unit 5 S.F. Lot # No. 2640 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 4����F1:Eps��O Q BERMUDA DUNES O (n RANCHO MIRAGE t7 JINOIAN WELLS P LMOESERT LA QUINTA �y INDIO a 774-122-026 La Quinta 1 Street S.F. RECEIVED JUL - 9 2013 Comments CM OF LA CO"(J 1/QFU' InN,,TA At the present time, the Desert Sands Unified School District does not collect Fees on garages/carports, covered patios/walkways, ys,, rYitl�rWNff fti s under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65935 Et Seq. in the amount of $3.20 X 2,640 S.F. or $8,448.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC -US Bank - Ron Stockdale Bank Name/Recipient of Certificate By Dr. Gary Rutherford Superintendent Fee collected lexemffi)bAby SrfiardGWcGi Check No. 5214500971 Telephone 310-801-5723 Funding Residential Payment Recd $8 448 00 ta'ver/l:rde� Signature NOTICE: Pursuant to Government Code Section 66 d)(1), this wjh�iicht otify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date onilding or installationpermit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public zed to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original =Building Department Applicant Copy - Applicant/Receipt Copy - Accounting Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 5/15/2013 Electronically Signed at Ca10ERTS.com by Laurie Oard (CT Properties, Inc.) 5/17/2013 i - PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Stockdale Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/15/2013 Project Address 53-725 Avenida Vallejo La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 2,640 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity ( Features see Part 2 of 5 Status Wall Wood Framed R-13 825 New Door Opaque Door None 28 New Roof Wood Framed Attic R-38 2,616 Radiant Barrier New Slab Unheated Slab -on -Grade None 2,640 Perim = 33' New FENESTRATION/ .: U. Exterior Orientation Are-' t`)`YFactor SHGC Overhang Sidefins Shades Status Front (E) 54.2 1'i 0.290 0.23 2.0 none -Bug Screen New Front (E), ;;-- 92.00.29 ,0.23 6;qN–*._ none p%*v0kBugxScreen,#n*,,,- New Front(E) 40.0•;f0.r290" „s. ;0.23 10.0` one' �,a8ug Scr en:x ,a. New Front E- ,i48 0+.1tt 0:290 0.23 X12: 0none t r r . (�{Bug Screen `, New— Front (E) ,.'; 6.0 , ; 0.710. (1$73 `2.Or; drone 'Bu Screen' '' '' New , S Left �fi (,)}- ., Bu Scr,✓ New. een `.%':rdi€°`"r� Left (SJ y+ ° 48.0 +: �,` fi' 0.290 `WT. d 0.23 s� i2 0 >� t _ T e Aye New ` 116.0 "-; t ,!6.290 0.23 140 r. 0 New 8.0. 0.290 0.23 2. oto reen ' New Right (N) 3B.0 f 0.290 0.23 2. r � r 1 en New r Right (N) 64 0_�. - " 0.290 0.23 20.0 o e I ug Screen New HVAC SYSTEMS - Ot . HeatingMin. Eff Cooli ATE Y mostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback ` New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Whole House Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 2 Small Gas 50 0.62 All Pipes Ins New f EnergyPro 5.1 by EnergySoft User Number. • 2655 RunCode: 2013-05-15710:51:01 ID: Pae 1 of 7 Reg: 213-N0029358A-000000000-0000 Registration Date/Time: 2013/05/15 13:52:24 HERS Provider: Ca10ERTS, Inc Electronically Filed by Joan D. Hacker and Authenticated at Ca10ERTS.com - 5/15/2013 Electronically Signed at CalCERTS.com by Laurie card (CT Properties, Inc.) 5/17/2013 it PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Stockdale Residence Building Type ® Single Family ❑'Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/15/2013 Project Address 53-725 Avenida Vallejo La Quinta California Energy Climate Zone CA Climate Zone 15 FT5iail Cond. Floor Area 1 2,640 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes; -A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -= If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special . Construction Type - Cavity ( Features see Part 2 of 5 'Status A • - 1 FENESTRATION/' = U- Exterior Orientation Area ft2 'Factor - SHGC Overhang' Sidefins Shades Status Right(N) :- 'b=`"t' 64.0.,'0.290 0.23 12.0 none Bug Screen New Skylightr�r 24.0,noneNone�r� New c ♦.�.y��p. ���.A...N;�`...�';;��9 1dd �I-'.ii�,d•f,j` SAL t: A"'I/. �5 r� }•a•!. 'y..1- }.w- 'fyy, •,i4' -.t �.r.w.sw, , Aayt I•�Sp r a�JRf4 'a*�` r�.,. ,,tS ry '' .: �f"f.1.�.s`+�' iv. '- 7�' 'J� r• :. Y:. - 4 �t: �%r.�� .�" i� f�'• .'+r...h +�+r. �:G'tTeYi•' �. ,�.�F��:+eR.^r�.�'I' 2s9y.y..,cr'L' X1'48.. i�e�r'q "i�.'�' �'•, s P11! �' , ";P" - HVAC SYSTEMS Ot . Heating Min. Eff 'Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location . Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons ...Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number, 2655 RunCode: 2013-05-15710:51:01 ID: Page 23771 Reg: 213-NO02935BA-000000000-0000 Registration Date/Time: 2013/05/15 13:52:24 HERS Provider: CalCERTS, Inc' Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 5/15/2013 Electronically Signed at Ca10ERTS.com by Laurie card (CT Properties, Inc.) 5/17/2013:` PERFORMANCE CERTIFICATE: Residential , ' - - Part.2 of 5 CF -1 R Project Name Stockdale Residence Building Type ®Single Family ❑ Addition Alone ❑ Multi Family ❑Existing+ Addition/Alteration Date 1511512013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the s ecial •ustification"and documentation submitted. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. _M y 1N`i. i .�"i4." T ' :rf�t ',u j•q,Sp. e; rt..:iz x,,p. f _.�r.w t, ..-•...`.s< r rr w.�y,^,,t.�w.•y7.w,,t�r+•._ 'TTt 4., �` . . *� � ■ �, HER&REQUIRED VERIFICATION ` ` � , try - p p� I(�� rXT. t' '4kY` .,� er, � � 'i�.`I 4 4 " J 5M i#.S � S JI V ✓�e1 4 Items m this section require field `test ng and/or verrficaUon bY;, bertifie8FHERS Rater The inspector trust receive a coin Ieted.CF,=4RJorrn or each of,the measures listed:below for -final to'bergiven �+ The Cooling System Day B Night INXA,660 GKA includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser• The -HVAC System'Who/e'House incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. a.ii-� "+• 'rtµ �._ - z ,c The HVAC System Whole House rates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. - EnergyPro I by EnergySoft User Number.• 2655 RunCode: 2013-05-15710:51:01 ID: Page 3 of 7 Reg: 213-N0029358A-000000000-0000 Registration Date/Tirre: 2013/05/15 13:52:24 b HERS Provider: CalCERTS, Inc I Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 5/15/2013 Electronically Signed at CalCERTS.com by Laurie Oard (CT Properties, Inc.) 5/17/2013 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R 'Project Name Building Type m Single Family ❑ Addition Alone Date Stockda/e Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 1511512013 ANNUAL ENERGY USE SUMMARY Standard_ Proposed Margin TDV kBtu/ft2- r Space Heating 1.71 2.91 -1.20 Space Cooling 47.40 40.01 7.39 Fans 9.41 11.47 --2.06 Domestic Hot Water 13.82 15.92 -2.10 Pumps o.o0 0.00 0.00' Totals 72.34 70.31 2.03 Percent Better Than Standard: 2.8% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 320 240 Fuel Available at Site: Natural Gas (S) 350 119 Raised Floor Area: 0 (w) 450 124 Slab on Grade Area: �., 2,640 (N) 380 164 Average Ceiling Height/ 10.0 Roof 2,640 24 Fenestration Average U -Factor: 0.29 TOTAL: 671 Average SHGC: `- 0.23 Fenestration/CFA Ratio: 25.4 REMARKS^`' :I;•.= �.. *; � 'q.'Y,r•i .s ;v. w.�.+.....,.,+.^e•,....r-,��'„7.1.4`'-`,,,�raNro�t�°'W'"} r7�.-'`n^'! y,.,-..+-_ _ STATEMENfbF_ COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24'-1Parts-1°the Administrative Regulations and Part 6 the Efficiency Standards of t'he California Code of Regulations.. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. I 5/1&2013 Address 77810 las Montanas Road, Suite 201 Name Joan D. Hacker , City/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Lench Design Studio Address 78215 Calle Cadiz Name City/State/Zip La Quinta, Ca 92253 Phone 760-564-1860 Signed License # Date EnemvPro 5.1 by EnemySoft User Number: 2655 RunCode: 2013-05-15T10:51:01 ID: Page 4 of 7 Reg: 213-N0029358A-000000000-0000 Registration Date/Time: 2013/05/15 13:52:24 HERS Provider: Ca10ERTS, Inc A Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - Electronically Signed at Ca10ERTS.com by Laurie card (CT Properties, Inc.) 5/15/2013 s/iv/,)niz CERTIFICATE OF COMPLIANCE: Residential Part 4 of .5 CF -1 R - Project Name Stockdale Residence Building Type m Single Family ❑ Addition AloneI ❑ Multi Family o Existing+ Addition/Alteration 1 Date 5/15/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix . Type Area Factor Cavity Exterior Frame Interior Frame Aim Tilt Status 4 Location/Comments Wall 80 0.102 R-13 90 90 New 4.3.1-A3 Whole House . Wall 203 0.102 R-13 180 90 New 4.3.1-A3 Whole House Door 28 0.500 None 180 90 New 4.5.1-A4 Whole House Wall 326 0.102 R-13 2701 90 New 4.3.1-A3 Whole House Wall 216 0.102 R-13 01 90 New 4.3.1-A3 Whole House Roof 2,616 0.025 R-38 270 0 New 4.2.1-A21 Whole House Slab 2,640 0.730 None 0 180 New 4.4.7-A1 Whole House FENESTRATION SURFACE DETAILS ID Type Area -/U-Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 14.2 '0.290 NFRC 0.23 NFRC 90 New IWC 6200 Alum/Low-E Whole House ,12,4 Window 40.0 0.290 NFRC 0.23 NFRC 90 New IWC 6200 Alum/Low-E Whole House ",3..: Window'•^ 128.0 0.290 NFRC 0.23 NFRC 90 New . IWC 6200 Alum/Low-E Whole House .4.', Window 40.0 0.290 NFRC 0.23 NFRC 90 New IWC 6200 Alum/Low-E Whole House 5 Window , - 48.0 0.290 NERC- ,4.0.23. NFRC - ,_,_„,90 New IWC 6200 Alum/Low_-E - Whole House 6 Window ' .`X64.0 0.290 'NFRC: f 0.23 NFRC :. - 90. New,,i -s IWC{6200-Alum1Low-E1ef Whole House 7 Window;P *.'r6.0 0.710 rDefault.1 ;, 0.73 'Default: ° n=- 90 New; ,4!,j Double'Metal-Cleai-t , ,�;,"� Whole House 8 Window' 17.2��0.29Q NFRC %', r; 0.23 NFRC,' . . ' 1 11° 180 Newr r IWC 6200 Alum/Low-E, Whole House--------.- 9 Window -40 '1,0.290 NFRC„l 0.23 NFRC: - V: 180 New: , F, 1WC 6200 Alum/Low-E ,Xh A", Whole,House � y� 10 Window-,, 25.0, j.'0.2,90 NFRC'!,) w 0.28 NFRCt-, ' �; 180 'New;�t 'IWC 6200 Alum/Low E j ' ; Who/e;Houset a'+� 11 f Window,41 `" U25.0 x,0.290 NFRCi `- x0.23 NFRC t :V.180 NewIWC 6200 Alum/Lo"w-E, 1�"4 Whole House,Wf4D" , 12,=, Window + ?K-48.0 10.290 NFRC "0.23 NFRC] -180 News,.-� �; IWC 6200 Alum/Low-EL Whole House '13 Window 20.0 0.290 NFRC," ' " " 0.23 NFRC 270 New IWC 6200 Alum/Low-E Whole House 114.„, Window-. ,•; +48.0 0.290 NFRC, 0.23 NFRC 270 New IWC 6200 A1um/Low-E Whole House 15• Window.,.; -'48:0 0.290 NFRC 0.23 NFRC 270 New IWC 6200 Alum/Low-E Whole House 16 ' Window 8.01k. 0.290 NFRC 0.23 NFRC 270 New IWC 6200 Alum/Low-E Whole House (1) U -Factor Type: ":".1.16-A =Default Table from Standards, NFRC =Labeled Value 2 . SHGC Type: ' 116=B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC Hot I Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len Hot Dist Len H t 1 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 8.0 2.5 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 8.0 3.5 6.0 0.1 6.0 6.0 . 4 Bug Screen 0.76 8.0 2.5 10.0 0.1 10.0 10.0 5 Bug Screen 0.76 8.0 6.0 12.01 0.1 12.01 12.0 6 Bug Screen 0.76 8.01 8.0 6.0 0.1 6.0 6.0 7 Bug Screen 0.76 2.0 3.0 2.0 0.1 2.0 2.0 8. Bug Screen 0.76 4.5 2.4 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 -5.0 5.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 5.0 5.0 2.01 0.1 2.0 2.0 12 Bug Screen 0.76 8.0 6.0 20.0 0.1 20.0 20.0 13 Bug Screen 0.76 4.0 5.0 `.10.0 0.1 10.0 10.0 14 lBug Screen 0.76 8.0 6.0 10.0 0.1 10.0 10.0 15 IBug Screen 0.76 8.0 6.0 10.0 0.1 10.0 _ 10.0 16 IBug Screen 0.76 4.0 5.0 2.0 0.11 2.01 2.0 EnergyPro 5.1 by EnergySoft User Number., 2655 RunCode: 2013-05-15710:51:01 ID: Page 5 of 7 Reg: 213-N0029358A-000000000-0000 Registration•Date/Time: 2013/05/15 13:52:24 'HERS'Provider: Ca10ERTS, Inc Electronically Filed by Joan D. Hacker and Authenticated at,Ca10ERTS.com - 5/15/2013 Electronically Signed at CalCERTS.com by Laurie Oard (CT Properties, Inc.) 5/17/2013 CERTIFICATE OF COMPLIANCE: Residential Part4 of 5 CF -1R. Project Name Stockdale Residence Building Type m Single Family ❑ Addition Alone • ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/15/2013 OPAQUE SURFACE DETAILS _ Surface Ll- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE.DETAILS - ID Type Area :,'Ll -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 4.0' : 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House ' -18._, Window 64.0. 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House 19'' Windows 4..r"• 8.0 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House ' -20-, Window 4.0 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House 21K Window#„" 4.0 0.290 NFRC_ New __ IWC 6200 Alum/LowyE _�_ -Whole House 22,T Window'µ 0.290 NFRC.-4;,1 0.23-.NFRC , x , -V0 New: ;, ;` IWCi6200 A1urii%Cow=Whole House 23 Windowe Ft'4:0 0.290 INFIRC:' ." 0.23'NFRC:;°,: F' 0 New.''M:,IWC 6200,'Aluin/Low-E 1. ? , Whole House -24 WindowF 64 0 0.290 ]NF,RCJ! ~1 0.23 NFRC,L<( 4, a'0 New,M4-. 'IWC 6200.'Aluin/Low-E _ V', -,Whole House~ . 25 Window �8t0 X0.290 NFRC•"f, r 0.23 NFRC:,,.' .;T,T-.�0 New;; t IWC 6200A1um/Low-E: A, Who/e;House .;,Z,,&- 26 skylight 4,124. 0, i' 0. 790 NFRC k' l 0.39 NFRC ., •,r270 'New,;, ' Doubllek- Whole,'House>fy' °"' 7 .t Y , • .h.=:'e,'^a.. r= -- ��1 �1 .1fk ?' 'Xwi" f' ."`.... tr-l-r;: X ,.tR.J1i iSz; '�.�`+**pe+ 1" a'#'' fKa?`iS:cir � xrt .i;,'.. _ e- .. � _':r:�r:. o.._:,.�:�' •���:!S-..zC..�!'-�:�,.....» ..'" (t) U -Factor Type: ' `I 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: `1.16-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Ri ht Fin ID Exterior Shade Type SHGC H t I Wd Len H t LExt I RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 2.01 2.0 2.0 0.1 2.01 2.0 18 Bug Screen 0.76 8.01 8.0 20.0 0.1 20.01 20.0 19 Bug Screen 0.76 4.01 2.0 2.0 0.1 2.01 2.0 20 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 1, .2.0 21 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 22 ' Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 a 23 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 24 Bug Screen 0.76 8.0 8.0 12.0 0.1 12.0 12.0 25 Bug Screen 0.76 4.01 2.0 '2.0 0.1 2.0 2.0 26 None 1.00 EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-05-15T10:51:01 ID: Page 6 of 7 Reg: 213-N0029358A-000000000-0000 Registration Date/Time: 2013/05/15 13:52:24' HERS Provider: Ca10ERTS, Inc Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 5/15/2013 Electronically Signed at Ca10ERTS.com by Laurie card (CT Properties, Inc.) 5/17/2013 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Stockdale Residence Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511512013 BUILDING ZONE INFORMATION Floor Area ft System Name Zone Name New Existinq Altered Removed Volume Year Built Whole House Whole Houser 2640 26,400 _'• ��`` Totals Z 6401 01 0 0 HVAC SYSTEMS .: ;S stem Name.,' Qty! 't.Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Whole Hous"''=" ` 2 .T Central Fumace 80% AFUE Split Air Conditioner 15.0 SEER Setback New Y at'?�M.1. �, T' r•5il•t.-:Y.�`i..pt .i .,L�t':.i �..: ".;G-. l}iiI ti,wi. 144'J:11H37a �7` �r dd '„� ,. r .y +r, A [ ' f�R �' ?"�,{: aSs•� �r :. ^ �--'k3+: � � - �'ii. K1: ' .tV4 r�i Ft6.:{. 1�5ft `- �: .i...�� :+.w ��."`.`.+�-1_'-.� yr-�0. ' HVAC.DISTRIBUTIO.N4VIS 4•j^ Y -Ir/wF �'"{� 4` 5 i ; '" + + f yli►�k:.e++.. j_t� DUct g4'0bcts ! r_., S stem,Name.�-'�� � .'Y atln ,. _ _..zCoolin t .- Duct Location- ��,R-Value Tested? Status Whole House.. ; ,, - Ducted ,`T ' Ducted Attic, Ceiling Ins, vented 8.0 m New ❑ ❑ WATER HEATING SYSTEMS' S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE 'Pilot Ext. Tank' Insul. R- Value Status A. 0. SMITH FPS -50-224 2 Small Gas All Pipes Ins 43,000 50 0.62 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o 0 Cn a — '. System Name . Pipe_ Len th Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑' i 10 ❑ 1, �E—ner—gyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-05-15710:51:01 ID: Pae 7 of 7 Reg: 213-N0029358A-000000000-0000 Registration Date/Time: 2013/05/15 13:52:24 HERS Provider: Ca10ERTS, Inc I BUILDING ENERGY ANALYSIS REPORT . r PROJECT: ' ` . Stockdale Residence 53-725 Avenida Vallejo La Quinta, CA Project Designer: r Lehch Design Studio 78215 Calle'Cadiz - .La Quinta,-Ca 92253 760-564-1860 Report Prepared by: s Joan D. -Hacker - Insu-form,- Inc. _ 177810 Las Montanas,Road, Suite 201 Palm Desert, Ca 92211 RE El VE 760-345-1352 MAY 2 0 2013 Y CITY OF LA�QUINTA COMMUNIS' DEVELOPNj DF LA UINTA' • l�Nr bPUr SAFE DEPT. BUIL ��® , ,PP ® TION . FOR CONSTR Date: - ATE The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnerggSoft, LLC —www.energysoft.com. Ener Pro 5.1 by Ener Soft User Number: 2655 ` RunCode: 2013-05-13T14:13c52 ID: { ,. r � ,. � � a 'y. a � � - f .. � 4 _' . � �. ..Z i a � .. � f { ,. 'y. � � a � 4 � f PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Stockdale Residence Building Type m Single Family O Addition Alone ❑ Multi Family O Existing+ Addition/Alteration Date 5/13/2013 Project Address 53-725 Avenida Vallejo La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,640 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures --.If Yes, A CF -4R must be provided per Part 2 of 5 of this form. IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Wall Wood Framed R-13 825 New Door" Opaque Door None 28 New Roof Wood Framed Attic R-38 2,616 Radiant Barrier New Slab Unheated Slab -on -Grade None 2,640 Perim = 33' New FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Front (E) 54.2 0.290 0.23 2.0 none Bug Screen New Front (E) 92.0 0.290 0.23 6.0 none Bug Screen New Front (E) 40.0 0.290 0.23 10.0 none Bug Screen New Front (E) 48.0 0.290 0.23 12.0 none Bug Screen New Front (E) 6.0 0.710 0.73 2.0 none Bug Screen New Leff (S) 71.2 0.290 0.23 2.0 none Bug Screen New Left (S) 48.0 0.290 0.23 20.0 none Bug Screen New Rear (lM 116.0 0.290 0.23 10.0 none Bug Screen New Rear (W 8.0 0.290 0.23 2.0 none Bug Screen New Right (N) 36.0 0.290 0.23 2.0 none Bug Screen New Right (N) 64.0 0.290 0.23 20.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Whole House Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Small Gas 50 0.62 All Pipes Ins New Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-05-13714:13:52 ID: Pa e 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Stockdale Residence. Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/13/2013 Project Address 53-725 Avenida Vallejo La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,640 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Right (N) 64.0 0.290 0.23 12.0 none Bug Screen New Skylight 24.0 0.700 0.39 none none None New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-05-13714:13:52 ID: Page 4 of 13 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Stockdale Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/13/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Day & Night INXA 660 GKA includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System Whole House incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System Whole House incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ene Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-05-13714:13:52 ID: Page 5 of 13 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family 13Addition Alone Date Stockdale Residence ❑Multi Family ❑Existing+ Addition/Alteration 5/13/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 1.71 2.91 -1.20 Space Cooling 47.40 40.01 7.39 Fans 9.41 11.47 -2.06 Domestic Hot Water 13.82 15.92 -2.10 Pumps 0.00 0.00 0.00 . Totals 72.34 70.31 , 2.03 Percent Better Than Standard: 2.8% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 ' (E) 320 240 Fuel Available at Site: Natural Gas (S) • 350 119 Raised Floor Area: 0 (VV) 450 124 Slab on Grade Area: 2,640 (N) 380 164 Average Ceiling Height: 10.0 Roof 2,640 24 Fenestration Average U -Factor: 0.29 TOTAL: 671 Average SHGC: 0.23 Fenestration/CFA Ratio: 25.4% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. P The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. 5/13 013 Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker Cit /State/Zi Palm Desert, Ca 92211 Phone 760-345 1352 Si ned Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business,& Professions Code) Company Lench Design Studio Address 78215 Calle Cadiz Name /�(. PC A City/State/Zip La Quinta, Ca 92253 Phone/760-564-1860 7Signed License # S �• D ate / S EnergyPro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-05-13714:13:52 ID: Page 6 of 13 101 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Stockdale Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511312013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 80 0.102 R-13 90 90 New 4.3.1-A3 Whole House Wall 203 0.102 R-13 180 90 New 4.3.1-A3 Whole House Door 28 0.500 None 180 90 New 4.5.1-A4 Whole House Wall 326 0.102 R-13 270 90 New 4.3.1-A3 Whole House Wall 216 0.102 R-13 0 90 New 4.3.1-A3 Whole House Roof Z 6161 0.025 R-38 270 0 New 4.2.1-A21 Whole House Slab Z 6401 0.730 None 0 180 New 4.4.7-A1 Whole House FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Window 14.2 0.290 NFRC 0.23 NFRC 90 New IWC 6200 Alum/Low-E Whole House 2 Window 40.0 0.290 NFRC 0.23 NFRC 90 New IWC 6200 Alum/Low-E Whole House 3 Window 28.0 0.290 NFRC 0.23 NFRC 90 New IWC 6200 Alum/Low-E Whole House 4 Window 40.0 0.290 NFRC 0.23 NFRC 90 New IWC 6200 Alum/Low-E Whole House 5 Window 48.0 0.290 NFRC 0.23 NFRC 90 New IWC 6200 Alum/Low-E Whole House 6 Window 64.0 0.290 NFRC 0.23 NFRC 90 New IWC 6200 Alum/Low-E Whole House 7 Window 6.0 0.710 Default 0.73 Default 90 New Double Metal Clear Whole House 8 Window 17.2 0.290 NFRC 0.23 NFRC 180 New IWC 6200 Alum/Low-E Whole House 9 Window 4.0 0.290 NFRC 0.23 NFRC 180 New IWC 6200 Alum/Low-E Whole House 10 Window 25.0 0.290 NFRC 0.23 NFRC 180 New IWC 6200 Alum/Low-E Whole House 11 Window 25.0 0.290 NFRC 0.23 NFRC 180 New IWC 6200 Alum/Low-E Whole House 12 Window 48.0 0.290 NFRC 0.23 NFRC 180 New IWC 6200 Alum/Low-E Whole House 13 Window 20.0 0.290 NFRC 0.23 NFRC 270 New IWC 6200 Alum/Low-E Whole House 14 Window 48.0 0.290 NFRC 0.23 NFRC 270 New IWC 6200 Alum/Low-E Whole House 15 Window 48.0 0.290 NFRC 0.23 NFRC 270 New IWC 6200 Alum/Low-E Whole House 16 Window 8.0 0.290 NFRC 0.23 NFRC 270 New IWC 6200 Alum/Low-E Mole House (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hot Wd Ove hang Left Fin Ri ht Fin Len I Hot LExt I RExt Dist Len Hot Dist Len H t 1 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 8.0 2.5 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 8.0 3.5 6.0 0.1 6.0 6.0 4 Bug Screen 0.76 8.0 2.5 10.0 0.1 10.0 10.0 5 Bug Screen 0.76 8.0 6.0 12.0 0.1 12.0 12.0 6 Bug Screen 0.76 8.0 8.0 6.0 0.1 6.0 6.0 7 Bug Screen 0.76 2.0 3.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 4.5 2.4 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 8.0 6.0 20.0 0.1 20.0 20.0 13 Bug Screen 0.76 4.0 5.0 10.0 0.1 10.0 10.0 14 Bug Screen 0.76 8.0 6.01 10.0 0.110.0 10.0 15 Bu Screen 0.76 8.0 6.0 10.0 0.1 10.0 10.0 16 Bu Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 Ener Pro 5.1 by Ener Soft User Number.' 2655 RunCode: 20 13-05-1 3 714:13:52 ID: Pae 7 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Stockdale Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/13/2013 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 17 Window 4.0 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House 18 Window 64.0 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House 19 Window 8.0 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House 20 Window 4.0 0.290 NFRC 0.23 NFRC 0 New IWC 6200 AlumA-ow-E Whole House 21 Window 4.01 0.290 NFRC 1 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House 22 Window 4.0 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House 23 Window 4.0 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House 24 Window 64.0 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House 25 Window 8.0 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House 26 Skylight 24.0 0.700 NFRC 0.39 NFRC 270 New Double Whole House (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt I RExt Dist I Len H t Dist Len H t 17 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.01 2.0 18 Bug Screen 0.76 8.0 8.0 20.0 0.1 20.0 20.0 19 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 20 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 21 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 22 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 23 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 24 Bug Screen 0.76 8.0 8.0 12.0 0.1 12.0 12.0 25 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 26 None 1.00 Ener Pro 5.1 by Ene Soft User Number: 2655 RunCode: 2013-05-13714:13:52 ID: Page 8 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Stockdale Residence Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ' ❑ Existing+ Addition/Alteration Date 5/13/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existinq Altered Removed Volume Year Built Mole House Whole Houser 2,640 26,400 Totals 1 2,6401 01 01 01 1 HVAC SYSTEMS System Name Qty. I Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Whole House 2 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Coolin Duct Location R -Value Ducts Tested? Status Whole House Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A. 0. SMITH FPS -50-224 2 Small Gas All Pipes Ins 43,000 50 0.62 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o co v ¢ — System Name Pipe Length Pipe Diameter Insul. Thick. Qt .HP Plenum Outside Buried Ene Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-05-13T14:13:52 ID: Pae 9 of 13 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 " MF -1 R Project Name ' • - f • Date 1 5/13/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 " MF -1 R Project Name ' • - f • Date Stockdale Residence 5/13/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk(*) below: This Mandatory Measures Summary shall be, incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: ' 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.: §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the , installation of a Cool Roof is specified on the CF -1 R Form. - '§l 50 a :Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. ' 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. ; *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. §150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.' 1 50 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.. Fireplaces, Decorative Gas Appliances and Gas Log Measures: ' 150 e 1 A: Mason or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. .' §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air-intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing S -stern Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units,and High -Rise residential occupancies meet the air release .valve, backflow pr6vention, pump isolation valve, and recirculation loop connection requirements of §113(6)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances '(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters: - 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. ' §150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). ' §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped With insulation having an installed thermal resistance of R-12 or greater. *v §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R=16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. . . §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire,length of recirculatinq sections of hot water pipes are insulated per. Standards Table .150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. - §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §1500)k Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance and wind. §150(j)3A: Insulation forchilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in ' conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Ratin •and Certification Corporation d13 EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-05-13T14:13:52 ID: Page 10 of MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Stockdale Residence 5/13/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause de radation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-05-13T14:13:52 ID: Page 11 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name b Date Stockdale Residence 5/13/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceilin . §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2 013-0 5-13 714:13:52 ID: Page 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Stockdale Residence Date 5/13/2013 System Name Whole House Floor Area 2,640 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,084 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD-- COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 70,000 26,126 2,448 644 23,803 Total Out ut Btuh 140,000 0 Output Btuh/s ft 53.0 1,508 1,170 Cooling System 0 0 Output per System 42,000 0 0 0 0 Total Output Btuh 84,000 0 2,448 0 Total Output Tons 7.0 1,508 1,170 Total Output Btuh/s ft 31.8 Total Output s tt/Ton 377.1 I 29,143 26,143 Air System CFM per System 2,055 HVAC EQUIPMENT SELECTION Airflow cfm 4,110 Day & Night INXA 660 GKA 61,828 9,947 140,000 140,000 Jan 1 AM Airflow cfm/s ft 1.56 Airflow cfm/Ton 587.1 , 'Outside Air % 0.0 % Total Adjusted System Output 61,828 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 9,947 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF r Outside Air 0 cfm Supply Fan 4,110 cfm 70 OF 70 OF 105 OF Heating Coil 105 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 78/63°F 78/63°F 55/54°F c Outside Air. • 0 cfm Supply I Fan Cooling Coil 55 / 54 OF 4,110 cfm 41.8% ROOM 78 / 63 OF 78/ 62 OF EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-05-13T14:13:52 ID: Page 13 of 13 POST IN A CONSPICUOUS PLACE Certificate of Occupancy Community Development Department This Certificate is issued pursuant to the requirements of Chapter 1 Section R110 of the California Residential Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 53-725 AVENIDA VALLEJO Use classification: SINGLE FAMILY DWELLING Building Permit No.: 13-0094 Occupancy Group: R-3 Type of Construction: VB Land Use Zone: RL Code Edition: 2010 Sprinkler Installed: YES Sprinkler Required: YES Owner of Building: STOCKDALE, CHARLES D Address: 50855 WASHINGTON ST, C217 City, ST, ZIP: LA QUINTA, CA 92253 ____________ GREG BUTLER_________________ By: KIRK KIRKLAND Building Official Date: MAY 30, 2014