13-0094 (SFDf
P.O. BOX 1504 ' f,
78-495 CALLE TAMPICO .
LA QUINTA, CALIFORNIA 92253.
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 8/22/13
Application Number: 13-00000094 - Owner:
Property Address: 53725 AVENIDA VALLEJO STOCKDALE
APN: 774-122-026-12 -000000- 50-855 WASHINGTON ST C-217
Application description: DWELLING - SINGLE FAMILY DETACHED LA QUINTA, CA 92253
Property Zoning: COVE RESIDENTIAL
Application valuation: 177855 r;r-lWar�;.F
Contractor:Applicant: Architect or Engineer: CT BUILDERS INC 2613
3194 AIRPORT LOOP 26 STE C2
COSTA MESA, CA 92626 (ZUII�TA
(714)327-1710 rll ffl
Lic. No.: OOR SQUARE FOOT Lic. No.: 974805
-----------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury,that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Profession Is Code, and my License is in full force and effect.
License Class: B L'c R Ko.: 974805
� Data: V v-3Contractor:
L/
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.):
(_) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: N 01
Lender's Address:
LQPERMIT
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of conse6t to self -insure for workers' compensation, as provided ,
for by Section.3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier EXEMPT Policy Number EXEMPT
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
(/ 4 person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become su 'act to the workers' compensation provisions of Section
370QQ0 of the LaboroCodel fort it 1�y withthoseprov'sions.
Dater � /5Applican-WANING: FAILURE TO SECURE ORKERSCOMPENSATION COVERAGE IS UNLAWFUL, AND SHALL -
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Ouinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
off this ounty t , meerr upon the above-mentioned party for in coon s
(Dat -2&!e— ignature (Applicant or<Agent):
w
Application Number
. . . . 13-00000094
Permit . . .
BUILDING PERMIT
Additional desc .
Permit Fee . . ..
828.50
Plan Check Fee
538.53
Issue Date
;Valuation :' . . .
153916
Expiration Date
1/04/14 .
Qty Unit Charge
Per
Extension
BASE
FEE
639.50
54..00 3.5000
THOU BLDG
100,001•=500,000'- -
'189.00. -
----------------------------------------------------------------------------
Permit .
ELEC-NEW RESIDENTIAL
Additional'desc .
Permit Fee
254.40
Plan Check Fee
63.60
Issue Date . . .
Valuation . . .
0
Expiration Date
1/04/14.
Qty Unit Charge
Per
Extension ,
BASE
FEE
15.00
2640.00 .0300
ELEC
NEW RES - MULTI FAMILY
79.20
" 2640.00 .0350
ELEC
NEW RES - 1 OR 2 FAMILY
92.40
2640.00 .0200
ELEC
GARAGE OR NON-RESIDENTIAL
52.80
1.00 15.0000
EA ELEC
TEMPORARY POWER POLE
15.00
Permit . . .
GRADING PERMIT
Additional desc .
Permit Fee
135.00
Plan Check Fee
.00
Issue Date
Valuation
0
Expiration Date
1/04/14
Qty Unit Charge
Per
Extension
BASE
FEE
117.00.
2.00 9.0000
---------------------------------------------
THOU GRADING 1001-10,000
--------------------------------
18.00
' Permit . . .
MECHANICAL
Additional desc .
Permit Fee
.77.00
Plan Check Fee
19.25
Issue Date . . . .
Valuation
0
Expiration Date
1/04/14 .
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
2.00 9.0000
EA MECH
FURNACE <=100K-.
18.00
2.00 9.0000
EA MECH
B/C <=3HP/100K.BTU
18.00
3.00 6.5000
EA MECH
VENT FAN
19.50
LQPERmrr
LQPERMIT
Application Number
13-00000094
Permit . . . . MECHANICAL
Qty Unit Charge Per
Extension
1.00 6.5000 EA
----------------------------------------------------------------------------
MECH EXHAUST HOOD
6.50-'
Permit . . . PLUMBING
Additional desc .
Permit Fee . . . . 234.75
Plan Check Fee
58.69
Issue.Date _
Valuation . . ...
0
Expiration Date 1/04/14
Qty Unit Charge Per-
Extension
-
BASE FEE
15.00
21.00 6.0000 EA
PLB FIXTURE
126.00
1.00 15.0000 -EA
. PLB BUILDING SEWER
15.00'
6:00 6.0000 EA
PLB ROOF DRAIN
36.00
2.00 7.5000 EA,:
PLB WATER HEATER/VENT-
15.00
1.00 3.0000 EA
PLB WATER INST/ALT/REP
3.00
.1.00 9.0000 EA
PLB LAWN SPRINKLER SYSTEM
9.00.
1.00 7500 EA
PLB GAS PIPE >=5
.75
1.00 15.0000 EA
PLB GAS METER.,
15.00
----- - ---
------------------------------------------
Sp
Special Notes and Comments
------------------------
2640 SQ._ FT. SFD WITH 818
SQ. FT. PATIO
AND 539 SQ. FT. GARAGE.PER
2010 CALIF
BUILDING CODES.
June 26, 2013 10:52:18 -AM
JJOHNSON.
this per does,not include
pool.spa or
block walls.
July 31, 2013 8:45:42 AM
jjohnson.
Other Fees . .
BLDG STDS ADMIN (SB1473)
7.00
DIF COMMUNITY CENTERS -RES
104.00
DIF CIVIC CENTER - RES
942.00
ENERGY REVIEW FEE
53.85
DIF FIRE PROTECTION -RES
433.00
GRADING PLAN CHECK FEE
15.00
DIF LIBRARIES - RES
344.00
MULTI -SPECIES (MSHCP) FEE
531'.00
DIF PARK MAINT FAC - RES
40.00
DIF PARKS/REC - RES
2048.00
COVE PRECISE PLAN FEE
100.00
STRONG MOTION (SMI) - RES
17.02
TUMF: RESIDENTIAL
1837.44
DIF STREET MAINT FAC -RES
116.00.
DIF TRANSPORTATION - RES
2842.00
Fee summary. Charged'
Paid Credited
Due
'Application Number
. . .
13-00000094
Permit Fee Total
1529.65.
.00
.00
1529.65
Plan Check Total
680.07
500.00
.00
180.07
Other Fee Total*
9430.31
.00
..00
9430.31
Grand Total
11640.03
500.00
11140.03
.00
s
Ei1VI;ANDS/iC
CFM OF Ttn�v
Return check to requestor Mail check
Name / Title of person requesting check
�mcmA
A-o�-C-
Depan,pient individual is associated with:
Check payable to: r
Nvic Amount: $ `1 0 0
(Name) ( (Vendor �No.) /'
Account Number:
(Address)
oo
Project Number: �r
Check description and invoice number:
14- 1.4 P77 Q 4
u
Signature:
(DepartmentHead)
(Date)
k }}`APPROVEb FOR�PAA' ENT
µ = (Finance Depar6hent Use Ohl
i
ttr L "J.�f
Z,sh,"
,,ACCOUNTNOr
fR tui l
"jDESCRI�PpTN�
IO:'
'A*
+ l W«.r�'�
?7ftss .:.,+�'2T.f F' •: . 4 ?:_si " - ;.Y ..gyp`. �• - y -;r - .:.,.
lTitv/ 4.4 a"
Ak P.O. BOX 1504 APPLICATION ONLY
Building %CLTAMPICO
Address
*� IN ,CALIFORNIA
92253
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work
for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
FINAL DATE
Issued by:
Validated by:
Validation:
YELLOW = APPLICANT
Front Setback from Center
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
de Setback from Property Line
INSPECTOR
Date Permit
PINK = FINANCE
BUILDING: TYPE CONST.
A.Number
P.
1 OCC. GRP.
2Zk L
If
Address
Add
Legal Description
Project Description
Z�
ity
Zip
Tel.
Contractor
��
Address
City
Zip
Tel.
Sq. Ft. j/�,Q,f�
Size C_jC lJ
No. No. Dw.
Stories Units
State Lic.
& Classif.
City
Lic. #
Arch., Engr.,� ��
New Add ❑ Alter ❑ Repair ❑ Demolition 11Designer
V
Addre � Tel. <2D
7ko .S'70,/07 i
Cjtty - �A Zi
State
Lic. #
LICENSED CONTRACTOR'S 15ECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
Estimated Valuation
4
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
3 of the Business and Professions Code, or that he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars (5500).
z -
PERMIT
AMOUNT
Plan Chk. Dep.
&,PDivision
$Teo . ._, 1 ;p gat
Plan Chk. Bal.
❑ I, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon and who does such work himself or through his own employees, provided
that such improvements are not intended or offered for sale. If, however, the building or im-
provement is sold within one year of completion, the owner -builder will have the burden of
proving that he did not build or improve for the purpose of sale).
01, as owner of theroe
p p rty, am exclusively contracting with licensed contractors to construct
the project. (Sec. 7044, Business and Professions Code: The Contractor's License law does
not apply to an owner of property who builds or improves thereon, and who contracts for such
projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Const.
Mech.
Electrical
Plumbing
- -
S.M.I.
Grading
Driveway Enc.
-------
Date-Owner
Infrastructure
WORKER'S COMPENSATION DECLARATION
It
1 hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
U9013
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less).
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to Workers' Compensation Laws of
California.
TOTAL
REMARKS
r n ct
JeN u
I
T '
e11r1 ANCE DEP
Date Owner
NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
ZONE: BY:
Minimum Setback Distances:
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work
for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
FINAL DATE
Issued by:
Validated by:
Validation:
YELLOW = APPLICANT
Front Setback from Center
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
de Setback from Property Line
INSPECTOR
Date Permit
PINK = FINANCE
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
Date 7/9/13 La Quinta, CA 92253
No. 31715 (760) 771-8515
Owner Ronald & Charlie Stockdale APN #
Address 50855 Washington St. C-217 Jurisdiction
City La Quinta Zip Permit #
Tract # No. of Units
Type Single Family Residence
Lot # No. Street
Unit 1 53725 Avenida Vallejo
Unit 2
Unit 3
Unit 4
Unit 5
S.F. Lot # No.
2640 Unit 6
Unit 7
Unit 8
Unit 9
Unit 10
4����F1:Eps��O
Q BERMUDA DUNES O
(n RANCHO MIRAGE t7
JINOIAN WELLS
P LMOESERT
LA QUINTA �y
INDIO
a
774-122-026
La Quinta
1
Street S.F.
RECEIVED
JUL - 9 2013
Comments CM OF LA
CO"(J 1/QFU' InN,,TA
At the present time, the Desert Sands Unified School District does not collect Fees on garages/carports, covered patios/walkways, ys,, rYitl�rWNff fti s under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65935 Et Seq.
in the amount of $3.20 X 2,640 S.F. or $8,448.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC -US Bank - Ron Stockdale
Bank Name/Recipient of Certificate
By Dr. Gary Rutherford
Superintendent
Fee collected lexemffi)bAby SrfiardGWcGi
Check No. 5214500971
Telephone 310-801-5723
Funding Residential
Payment Recd
$8 448 00
ta'ver/l:rde�
Signature
NOTICE: Pursuant to Government Code Section 66 d)(1), this wjh�iicht
otify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date onilding or installationpermit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public zed to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original =Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 5/15/2013
Electronically Signed at Ca10ERTS.com by Laurie Oard (CT Properties, Inc.) 5/17/2013
i -
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Stockdale Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/15/2013
Project Address
53-725 Avenida Vallejo La Quinta
California Energy Climate Zone
CA Climate Zone 15
I Total Cond. Floor Area
2,640
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity ( Features see Part 2 of 5 Status
Wall Wood Framed R-13 825 New
Door Opaque Door None 28 New
Roof Wood Framed Attic R-38 2,616 Radiant Barrier New
Slab Unheated Slab -on -Grade None 2,640 Perim = 33' New
FENESTRATION/ .: U. Exterior
Orientation Are-' t`)`YFactor SHGC Overhang Sidefins Shades Status
Front (E) 54.2 1'i 0.290 0.23 2.0 none -Bug Screen New
Front (E), ;;-- 92.00.29 ,0.23 6;qN–*._ none p%*v0kBugxScreen,#n*,,,- New
Front(E) 40.0•;f0.r290" „s. ;0.23 10.0` one' �,a8ug Scr en:x ,a. New
Front E- ,i48 0+.1tt 0:290 0.23 X12: 0none t r r . (�{Bug Screen `, New—
Front (E) ,.'; 6.0 , ; 0.710. (1$73 `2.Or; drone 'Bu Screen' '' '' New
,
S
Left �fi
(,)}- ., Bu Scr,✓ New.
een
`.%':rdi€°`"r�
Left (SJ y+ ° 48.0 +: �,` fi' 0.290 `WT. d 0.23 s� i2 0 >� t _ T e Aye
New
`
116.0 "-; t ,!6.290 0.23 140 r. 0 New
8.0. 0.290 0.23 2. oto reen ' New
Right (N) 3B.0 f 0.290 0.23 2. r � r 1 en New
r
Right (N) 64 0_�. - " 0.290 0.23 20.0 o e I ug Screen New
HVAC SYSTEMS -
Ot . HeatingMin. Eff Cooli ATE Y mostat Status
2 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback ` New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
Whole House Ducted Ducted Attic, Ceiling Ins, vented 8.0 New
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
2 Small Gas 50 0.62 All Pipes Ins New
f
EnergyPro 5.1 by EnergySoft User Number. • 2655 RunCode: 2013-05-15710:51:01 ID:
Pae 1 of 7
Reg: 213-N0029358A-000000000-0000 Registration Date/Time: 2013/05/15 13:52:24 HERS Provider: Ca10ERTS, Inc
Electronically Filed by Joan D. Hacker and Authenticated at Ca10ERTS.com - 5/15/2013
Electronically Signed at CalCERTS.com by Laurie card (CT Properties, Inc.) 5/17/2013
it
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Stockdale Residence
Building Type ® Single Family ❑'Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/15/2013
Project Address
53-725 Avenida Vallejo La Quinta
California Energy Climate Zone
CA Climate Zone 15
FT5iail Cond. Floor Area
1 2,640
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes; -A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -= If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special .
Construction Type - Cavity ( Features see Part 2 of 5
'Status
A
• -
1
FENESTRATION/' = U- Exterior
Orientation Area ft2 'Factor - SHGC Overhang' Sidefins Shades
Status
Right(N) :- 'b=`"t' 64.0.,'0.290 0.23 12.0 none Bug Screen
New
Skylightr�r 24.0,noneNone�r�
New
c ♦.�.y��p. ���.A...N;�`...�';;��9
1dd �I-'.ii�,d•f,j` SAL t: A"'I/. �5 r� }•a•!. 'y..1- }.w- 'fyy, •,i4' -.t �.r.w.sw,
,
Aayt I•�Sp
r
a�JRf4 'a*�` r�.,.
,,tS ry
'' .: �f"f.1.�.s`+�' iv. '- 7�' 'J� r• :.
Y:. - 4 �t: �%r.�� .�" i� f�'• .'+r...h +�+r. �:G'tTeYi•' �. ,�.�F��:+eR.^r�.�'I' 2s9y.y..,cr'L'
X1'48.. i�e�r'q "i�.'�' �'•, s P11! �' , ";P"
-
HVAC SYSTEMS
Ot . Heating Min. Eff 'Cooling Min. Eff Thermostat
Status
HVAC DISTRIBUTION Duct
Location . Heating Cooling Duct Location R -Value
Status
WATER HEATING
Ot . Type Gallons ...Min. Eff Distribution
Status
EnergyPro 5.1 by EnergySoft User Number, 2655 RunCode: 2013-05-15710:51:01 ID:
Page 23771
Reg: 213-NO02935BA-000000000-0000 Registration Date/Time: 2013/05/15 13:52:24 HERS Provider: CalCERTS, Inc'
Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 5/15/2013
Electronically Signed at Ca10ERTS.com by Laurie card (CT Properties, Inc.) 5/17/2013:`
PERFORMANCE CERTIFICATE: Residential , ' - - Part.2 of 5 CF -1 R
Project Name
Stockdale Residence
Building Type ®Single Family ❑ Addition Alone
❑ Multi Family ❑Existing+ Addition/Alteration
Date
1511512013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the s ecial •ustification"and documentation submitted.
The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
_M
y
1N`i. i .�"i4." T ' :rf�t
',u
j•q,Sp. e; rt..:iz x,,p. f _.�r.w t, ..-•...`.s< r rr w.�y,^,,t.�w.•y7.w,,t�r+•._
'TTt 4., �` . . *� � ■ �,
HER&REQUIRED VERIFICATION ` ` � , try - p p� I(�� rXT.
t' '4kY` .,� er, � � 'i�.`I 4 4 " J 5M i#.S � S JI V ✓�e1 4
Items m this section require field `test ng and/or verrficaUon bY;, bertifie8FHERS Rater The inspector trust receive a
coin Ieted.CF,=4RJorrn or each of,the measures listed:below for -final to'bergiven �+
The Cooling System Day B Night INXA,660 GKA includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of
the correct Condenser•
The -HVAC System'Who/e'House incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
a.ii-� "+• 'rtµ �._ -
z ,c
The HVAC System Whole House rates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that
duct leakage meets the specified criteria. -
EnergyPro I by EnergySoft User Number.• 2655 RunCode: 2013-05-15710:51:01 ID: Page 3 of 7
Reg: 213-N0029358A-000000000-0000 Registration Date/Tirre: 2013/05/15 13:52:24
b
HERS Provider: CalCERTS, Inc
I
Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 5/15/2013
Electronically Signed at CalCERTS.com by Laurie Oard (CT Properties, Inc.) 5/17/2013
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
'Project Name
Building Type m Single Family ❑ Addition Alone
Date
Stockda/e Residence
❑ Multi Family ❑ Existing+ Addition/Alteration
1511512013
ANNUAL ENERGY USE SUMMARY
Standard_ Proposed Margin
TDV kBtu/ft2- r
Space Heating 1.71 2.91 -1.20
Space Cooling 47.40 40.01 7.39
Fans 9.41 11.47 --2.06
Domestic Hot Water 13.82 15.92 -2.10
Pumps o.o0 0.00 0.00'
Totals 72.34 70.31 2.03
Percent Better Than Standard: 2.8%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 320 240
Fuel Available at Site: Natural Gas (S) 350 119
Raised Floor Area: 0 (w) 450 124
Slab on Grade Area: �., 2,640 (N) 380 164
Average Ceiling Height/ 10.0 Roof 2,640 24
Fenestration Average U -Factor: 0.29 TOTAL: 671
Average SHGC: `- 0.23 Fenestration/CFA Ratio: 25.4
REMARKS^`' :I;•.=
�.. *; � 'q.'Y,r•i .s ;v. w.�.+.....,.,+.^e•,....r-,��'„7.1.4`'-`,,,�raNro�t�°'W'"} r7�.-'`n^'! y,.,-..+-_ _
STATEMENfbF_ COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24'-1Parts-1°the Administrative Regulations and Part 6 the
Efficiency Standards of t'he California Code of Regulations..
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc. I
5/1&2013
Address 77810 las Montanas Road, Suite 201 Name Joan D. Hacker ,
City/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Lench Design Studio
Address 78215 Calle Cadiz Name
City/State/Zip La Quinta, Ca 92253 Phone 760-564-1860 Signed License # Date
EnemvPro 5.1 by EnemySoft User Number: 2655 RunCode: 2013-05-15T10:51:01 ID: Page 4 of 7
Reg: 213-N0029358A-000000000-0000 Registration Date/Time: 2013/05/15 13:52:24 HERS Provider: Ca10ERTS, Inc
A
Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com -
Electronically Signed at Ca10ERTS.com by Laurie card (CT Properties, Inc.)
5/15/2013
s/iv/,)niz
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of .5 CF -1 R -
Project Name
Stockdale Residence
Building Type m Single Family ❑ Addition AloneI
❑ Multi Family o Existing+ Addition/Alteration 1
Date
5/15/2013
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix .
Type Area Factor Cavity Exterior Frame Interior Frame Aim Tilt Status 4 Location/Comments
Wall 80 0.102 R-13
90 90 New 4.3.1-A3 Whole House .
Wall 203 0.102 R-13
180 90 New 4.3.1-A3 Whole House
Door 28 0.500 None
180 90 New 4.5.1-A4 Whole House
Wall 326 0.102 R-13
2701 90 New 4.3.1-A3 Whole House
Wall 216 0.102 R-13
01 90 New 4.3.1-A3 Whole House
Roof 2,616 0.025 R-38
270 0 New 4.2.1-A21 Whole House
Slab 2,640 0.730 None
0 180 New 4.4.7-A1 Whole House
FENESTRATION SURFACE DETAILS
ID Type Area -/U-Factor' SHGC
Azm Status Glazing Type Location/Comments
1 Window 14.2 '0.290 NFRC 0.23 NFRC
90 New IWC 6200 Alum/Low-E Whole House
,12,4 Window 40.0 0.290 NFRC 0.23 NFRC
90 New IWC 6200 Alum/Low-E Whole House
",3..: Window'•^ 128.0 0.290 NFRC 0.23 NFRC
90 New . IWC 6200 Alum/Low-E Whole House
.4.', Window 40.0 0.290 NFRC 0.23 NFRC
90 New IWC 6200 Alum/Low-E Whole House
5 Window , - 48.0 0.290 NERC- ,4.0.23. NFRC
- ,_,_„,90 New IWC 6200 Alum/Low_-E - Whole House
6 Window ' .`X64.0 0.290 'NFRC: f 0.23 NFRC
:. - 90. New,,i -s IWC{6200-Alum1Low-E1ef Whole House
7 Window;P *.'r6.0 0.710 rDefault.1 ;, 0.73 'Default: ° n=- 90 New; ,4!,j Double'Metal-Cleai-t , ,�;,"� Whole House
8 Window' 17.2��0.29Q NFRC %', r; 0.23 NFRC,'
. . '
1 11° 180 Newr r IWC 6200 Alum/Low-E, Whole House--------.-
9 Window -40 '1,0.290 NFRC„l 0.23 NFRC: - V: 180 New: , F, 1WC 6200 Alum/Low-E ,Xh A", Whole,House � y�
10 Window-,, 25.0, j.'0.2,90 NFRC'!,) w 0.28 NFRCt-,
' �; 180 'New;�t 'IWC 6200 Alum/Low E j ' ; Who/e;Houset a'+�
11 f Window,41 `" U25.0 x,0.290 NFRCi `- x0.23 NFRC t :V.180 NewIWC 6200 Alum/Lo"w-E, 1�"4 Whole House,Wf4D" ,
12,=, Window + ?K-48.0 10.290 NFRC "0.23 NFRC] -180 News,.-� �; IWC 6200 Alum/Low-EL Whole House
'13 Window 20.0 0.290 NFRC," ' " " 0.23 NFRC
270 New IWC 6200 Alum/Low-E Whole House
114.„, Window-. ,•; +48.0 0.290 NFRC, 0.23 NFRC
270 New IWC 6200 A1um/Low-E Whole House
15• Window.,.; -'48:0 0.290 NFRC 0.23 NFRC
270 New IWC 6200 Alum/Low-E Whole House
16 ' Window 8.01k. 0.290 NFRC 0.23 NFRC
270 New IWC 6200 Alum/Low-E Whole House
(1) U -Factor Type: ":".1.16-A =Default Table from Standards, NFRC =Labeled Value
2 . SHGC Type: ' 116=B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window
ID Exterior Shade Type SHGC Hot I Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len Hot Dist Len H t
1 Bug Screen 0.76 4.0 3.0
2.0 0.1 2.0 2.0
2 Bug Screen 0.76 8.0 2.5
2.0 0.1 2.0 2.0
3 Bug Screen 0.76 8.0 3.5
6.0 0.1 6.0 6.0 .
4 Bug Screen 0.76 8.0 2.5
10.0 0.1 10.0 10.0
5 Bug Screen 0.76 8.0 6.0
12.01 0.1 12.01 12.0
6 Bug Screen 0.76 8.01 8.0
6.0 0.1 6.0 6.0
7 Bug Screen 0.76 2.0 3.0
2.0 0.1 2.0 2.0
8. Bug Screen 0.76 4.5 2.4
2.0 0.1 2.0 2.0
9 Bug Screen 0.76 2.0 2.0
2.0 0.1 2.0 2.0
10 Bug Screen 0.76 -5.0 5.0
2.0 0.1 2.0 2.0
11 Bug Screen 0.76 5.0 5.0
2.01 0.1 2.0 2.0
12 Bug Screen 0.76 8.0 6.0
20.0 0.1 20.0 20.0
13 Bug Screen 0.76 4.0 5.0
`.10.0 0.1 10.0 10.0
14 lBug Screen 0.76 8.0 6.0
10.0 0.1 10.0 10.0
15 IBug Screen 0.76 8.0 6.0
10.0 0.1 10.0 _ 10.0
16 IBug Screen 0.76 4.0 5.0
2.0 0.11 2.01 2.0
EnergyPro 5.1 by EnergySoft User Number., 2655 RunCode: 2013-05-15710:51:01 ID: Page 5 of 7
Reg: 213-N0029358A-000000000-0000 Registration•Date/Time: 2013/05/15 13:52:24 'HERS'Provider: Ca10ERTS, Inc
Electronically Filed by Joan D. Hacker and Authenticated at,Ca10ERTS.com - 5/15/2013
Electronically Signed at CalCERTS.com by Laurie Oard (CT Properties, Inc.) 5/17/2013
CERTIFICATE OF COMPLIANCE: Residential Part4 of 5 CF -1R.
Project Name
Stockdale Residence
Building Type m Single Family ❑ Addition Alone •
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/15/2013
OPAQUE SURFACE DETAILS _
Surface Ll- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE.DETAILS -
ID Type Area :,'Ll -Factor SHGC Azm Status Glazing Type Location/Comments
17 Window 4.0' : 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House '
-18._, Window 64.0. 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House
19'' Windows 4..r"• 8.0 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House '
-20-, Window 4.0 0.290 NFRC 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House
21K Window#„" 4.0 0.290 NFRC_ New __ IWC 6200 Alum/LowyE _�_ -Whole House
22,T Window'µ 0.290 NFRC.-4;,1 0.23-.NFRC , x , -V0 New: ;, ;` IWCi6200 A1urii%Cow=Whole House
23 Windowe Ft'4:0 0.290 INFIRC:' ." 0.23'NFRC:;°,: F' 0 New.''M:,IWC 6200,'Aluin/Low-E 1. ? , Whole House
-24 WindowF 64 0 0.290
]NF,RCJ! ~1 0.23 NFRC,L<( 4, a'0 New,M4-. 'IWC 6200.'Aluin/Low-E _ V', -,Whole House~ .
25 Window �8t0 X0.290 NFRC•"f, r 0.23 NFRC:,,.' .;T,T-.�0 New;; t IWC 6200A1um/Low-E: A, Who/e;House .;,Z,,&-
26 skylight 4,124. 0, i' 0. 790 NFRC k' l 0.39 NFRC ., •,r270 'New,;, ' Doubllek- Whole,'House>fy' °"'
7 .t Y , • .h.=:'e,'^a.. r= -- ��1 �1 .1fk ?' 'Xwi" f' ."`.... tr-l-r;: X ,.tR.J1i iSz; '�.�`+**pe+
1" a'#'' fKa?`iS:cir � xrt .i;,'.. _ e- .. � _':r:�r:. o.._:,.�:�' •���:!S-..zC..�!'-�:�,.....» ..'"
(t) U -Factor Type: ' `I 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: `1.16-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window Ove hang Left Fin Ri ht Fin
ID Exterior Shade Type SHGC H t I Wd Len H t LExt I RExt Dist Len H t Dist Len H t
17 Bug Screen 0.76 2.01 2.0 2.0 0.1 2.01 2.0
18 Bug Screen 0.76 8.01 8.0 20.0 0.1 20.01 20.0
19 Bug Screen 0.76 4.01 2.0 2.0 0.1 2.01 2.0
20 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 1, .2.0
21 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0
22 ' Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 a
23 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0
24 Bug Screen 0.76 8.0 8.0 12.0 0.1 12.0 12.0
25 Bug Screen 0.76 4.01 2.0 '2.0 0.1 2.0 2.0
26 None 1.00
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-05-15T10:51:01 ID: Page 6 of 7
Reg: 213-N0029358A-000000000-0000 Registration Date/Time: 2013/05/15 13:52:24' HERS Provider: Ca10ERTS, Inc
Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 5/15/2013
Electronically Signed at Ca10ERTS.com by Laurie card (CT Properties, Inc.) 5/17/2013
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R
Project Name
Stockdale Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1511512013
BUILDING ZONE INFORMATION
Floor Area ft
System Name Zone Name New Existinq Altered Removed Volume Year Built
Whole House Whole Houser 2640 26,400
_'• ��`` Totals Z 6401 01 0 0
HVAC SYSTEMS
.: ;S stem Name.,' Qty! 't.Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Whole Hous"''=" ` 2 .T Central Fumace 80% AFUE Split Air Conditioner 15.0 SEER Setback New
Y at'?�M.1. �, T' r•5il•t.-:Y.�`i..pt .i .,L�t':.i �..: ".;G-. l}iiI ti,wi. 144'J:11H37a
�7` �r dd '„� ,. r .y
+r, A
[ ' f�R
�' ?"�,{: aSs•� �r :. ^ �--'k3+: � � - �'ii. K1: ' .tV4 r�i Ft6.:{. 1�5ft `- �: .i...�� :+.w ��."`.`.+�-1_'-.� yr-�0.
'
HVAC.DISTRIBUTIO.N4VIS 4•j^ Y -Ir/wF
�'"{� 4` 5 i ; '" + + f yli►�k:.e++.. j_t� DUct g4'0bcts !
r_., S stem,Name.�-'�� � .'Y atln ,. _ _..zCoolin t .- Duct Location- ��,R-Value Tested? Status
Whole House.. ; ,, - Ducted ,`T ' Ducted Attic, Ceiling Ins, vented 8.0 m New
❑
❑
WATER HEATING SYSTEMS'
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy Standby
Factor Loss or
or RE 'Pilot
Ext.
Tank'
Insul. R-
Value
Status
A. 0. SMITH FPS -50-224
2
Small Gas All
Pipes Ins
43,000
50
0.62 n/a
n/a
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
o
0 Cn
a —
'.
System Name .
Pipe_
Len th
Pipe
Diameter
Insul.
Thick.
Qty.
HP
Plenum
Outside Buried
❑'
i
10
❑
1,
�E—ner—gyPro
5.1 by EnergySoft User Number: 2655 RunCode: 2013-05-15710:51:01 ID: Pae 7 of 7
Reg: 213-N0029358A-000000000-0000 Registration Date/Time: 2013/05/15 13:52:24 HERS Provider: Ca10ERTS, Inc
I
BUILDING ENERGY ANALYSIS REPORT
. r
PROJECT: '
` . Stockdale Residence
53-725 Avenida Vallejo
La Quinta, CA
Project Designer:
r Lehch Design Studio
78215 Calle'Cadiz -
.La Quinta,-Ca 92253
760-564-1860
Report Prepared by:
s Joan D. -Hacker -
Insu-form,- Inc.
_ 177810 Las Montanas,Road, Suite 201
Palm Desert, Ca 92211 RE El
VE
760-345-1352
MAY 2
0 2013
Y CITY OF LA�QUINTA
COMMUNIS' DEVELOPNj
DF LA UINTA'
• l�Nr bPUr SAFE DEPT.
BUIL ��® ,
,PP ® TION .
FOR CONSTR
Date:
- ATE
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnerggSoft, LLC —www.energysoft.com.
Ener Pro 5.1 by Ener Soft User Number: 2655 ` RunCode: 2013-05-13T14:13c52 ID:
{
,.
r
� ,. � � a
'y.
a
� � - f
..
�
4 _'
. � �.
..Z
i
a �
..
�
f
{
,.
'y.
� �
a �
4
�
f
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Stockdale Residence
Building Type m Single Family O Addition Alone
❑ Multi Family O Existing+ Addition/Alteration
Date
5/13/2013
Project Address
53-725 Avenida Vallejo La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,640
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
IZI Yes ❑ No HERS Measures --.If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Wall Wood Framed
R-13 825 New
Door" Opaque Door
None 28 New
Roof Wood Framed Attic
R-38 2,616 Radiant Barrier New
Slab Unheated Slab -on -Grade
None 2,640 Perim = 33' New
FENESTRATION U-
Orientation Area Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (E) 54.2 0.290
0.23 2.0 none Bug Screen New
Front (E) 92.0 0.290
0.23 6.0 none Bug Screen New
Front (E) 40.0 0.290
0.23 10.0 none Bug Screen New
Front (E) 48.0 0.290
0.23 12.0 none Bug Screen New
Front (E) 6.0 0.710
0.73 2.0 none Bug Screen New
Leff (S) 71.2 0.290
0.23 2.0 none Bug Screen New
Left (S) 48.0 0.290
0.23 20.0 none Bug Screen New
Rear (lM 116.0 0.290
0.23 10.0 none Bug Screen New
Rear (W 8.0 0.290
0.23 2.0 none Bug Screen New
Right (N) 36.0 0.290
0.23 2.0 none Bug Screen New
Right (N) 64.0 0.290
0.23 20.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
2 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Whole House Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
2 Small Gas 50
0.62 All Pipes Ins New
Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-05-13714:13:52 ID:
Pa e 3 of 13
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Stockdale Residence.
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/13/2013
Project Address
53-725 Avenida Vallejo La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,640
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Right (N) 64.0 0.290 0.23 12.0 none Bug Screen New
Skylight 24.0 0.700 0.39 none none None New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-05-13714:13:52 ID:
Page 4 of 13
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Stockdale Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/13/2013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System Day & Night INXA 660 GKA includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of
the correct Condenser.
The HVAC System Whole House incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System Whole House incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that
duct leakage meets the specified criteria.
Ene Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-05-13714:13:52 ID: Page 5 of 13
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family 13Addition Alone
Date
Stockdale Residence
❑Multi Family ❑Existing+ Addition/Alteration
5/13/2013
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 1.71 2.91 -1.20
Space Cooling 47.40 40.01 7.39
Fans 9.41 11.47 -2.06
Domestic Hot Water 13.82 15.92 -2.10
Pumps 0.00 0.00 0.00 .
Totals 72.34 70.31 , 2.03
Percent Better Than Standard: 2.8%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 ' (E) 320 240
Fuel Available at Site: Natural Gas (S) • 350 119
Raised Floor Area: 0 (VV) 450 124
Slab on Grade Area: 2,640 (N) 380 164
Average Ceiling Height: 10.0 Roof 2,640 24
Fenestration Average U -Factor: 0.29 TOTAL: 671
Average SHGC: 0.23 Fenestration/CFA Ratio: 25.4%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations. P
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc.
5/13 013
Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker
Cit /State/Zi Palm Desert, Ca 92211 Phone 760-345 1352 Si ned Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business,& Professions Code)
Company Lench Design Studio
Address 78215 Calle Cadiz Name /�(. PC A
City/State/Zip La Quinta, Ca 92253 Phone/760-564-1860 7Signed License # S �• D ate
/ S
EnergyPro 5.1 by Ener Soft User Number: 2655 RunCode: 2013-05-13714:13:52 ID: Page 6 of 13
101
CERTIFICATE OF COMPLIANCE:
Residential (Part 4 of 5) CF -1 R
Project Name
Stockdale Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1511312013
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation
Factor Cavity Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Wall
80
0.102 R-13
90
90 New 4.3.1-A3
Whole House
Wall
203
0.102 R-13
180
90 New 4.3.1-A3
Whole House
Door
28
0.500 None
180
90 New 4.5.1-A4
Whole House
Wall
326
0.102 R-13
270
90 New 4.3.1-A3
Whole House
Wall
216
0.102 R-13
0
90 New 4.3.1-A3
Whole House
Roof
Z 6161
0.025 R-38
270
0 New 4.2.1-A21
Whole House
Slab
Z 6401
0.730 None
0
180 New 4.4.7-A1
Whole House
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC2
Azm Status Glazing Type
Location/Comments
1
Window
14.2 0.290 NFRC
0.23 NFRC
90 New
IWC 6200 Alum/Low-E
Whole House
2
Window
40.0 0.290 NFRC
0.23 NFRC
90 New
IWC 6200 Alum/Low-E
Whole House
3
Window
28.0 0.290 NFRC
0.23 NFRC
90 New
IWC 6200 Alum/Low-E
Whole House
4
Window
40.0 0.290 NFRC
0.23 NFRC
90 New
IWC 6200 Alum/Low-E
Whole House
5
Window
48.0 0.290 NFRC
0.23 NFRC
90 New
IWC 6200 Alum/Low-E
Whole House
6
Window
64.0 0.290 NFRC
0.23 NFRC
90 New
IWC 6200 Alum/Low-E
Whole House
7
Window
6.0 0.710 Default
0.73 Default
90 New
Double Metal Clear
Whole House
8
Window
17.2 0.290 NFRC
0.23 NFRC
180 New
IWC 6200 Alum/Low-E
Whole House
9
Window
4.0 0.290 NFRC
0.23 NFRC
180 New
IWC 6200 Alum/Low-E
Whole House
10
Window
25.0 0.290 NFRC
0.23 NFRC
180 New
IWC 6200 Alum/Low-E
Whole House
11
Window
25.0 0.290 NFRC
0.23 NFRC
180 New
IWC 6200 Alum/Low-E
Whole House
12
Window
48.0 0.290 NFRC
0.23 NFRC
180 New
IWC 6200 Alum/Low-E
Whole House
13
Window
20.0 0.290 NFRC
0.23 NFRC
270 New
IWC 6200 Alum/Low-E
Whole House
14
Window
48.0 0.290 NFRC
0.23 NFRC
270 New
IWC 6200 Alum/Low-E
Whole House
15
Window
48.0 0.290 NFRC
0.23 NFRC
270 New
IWC 6200 Alum/Low-E
Whole House
16
Window
8.0 0.290 NFRC
0.23 NFRC
270 New
IWC 6200 Alum/Low-E
Mole House
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
Hot Wd
Ove hang Left Fin Ri ht Fin
Len I Hot LExt I RExt Dist Len Hot Dist Len H t
1
Bug Screen
0.76
4.0 3.0
2.0 0.1
2.0 2.0
2
Bug Screen
0.76
8.0 2.5
2.0 0.1
2.0 2.0
3
Bug Screen
0.76
8.0 3.5
6.0 0.1
6.0 6.0
4
Bug Screen
0.76
8.0 2.5
10.0 0.1
10.0 10.0
5
Bug Screen
0.76
8.0 6.0
12.0 0.1
12.0 12.0
6
Bug Screen
0.76
8.0 8.0
6.0 0.1
6.0 6.0
7
Bug Screen
0.76
2.0 3.0
2.0 0.1
2.0 2.0
8
Bug Screen
0.76
4.5 2.4
2.0 0.1
2.0 2.0
9
Bug Screen
0.76
2.0 2.0
2.0 0.1
2.0 2.0
10
Bug Screen
0.76
5.0 5.0
2.0 0.1
2.0 2.0
11
Bug Screen
0.76
5.0 5.0
2.0 0.1
2.0 2.0
12
Bug Screen
0.76
8.0 6.0
20.0 0.1
20.0 20.0
13
Bug Screen
0.76
4.0 5.0
10.0 0.1
10.0 10.0
14
Bug Screen
0.76
8.0 6.01
10.0 0.110.0
10.0
15
Bu Screen
0.76
8.0 6.0
10.0 0.1
10.0 10.0
16
Bu Screen
0.76
4.0 5.0
2.0 0.1
2.0 2.0
Ener Pro 5.1 by Ener Soft User Number.' 2655 RunCode: 20 13-05-1 3 714:13:52 ID:
Pae 7 of 13
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Stockdale Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/13/2013
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor
SHGC2
Azm Status Glazing Type Location/Comments
17
Window 4.0
0.290 NFRC
0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House
18
Window 64.0
0.290 NFRC
0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House
19
Window 8.0
0.290 NFRC
0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House
20
Window 4.0
0.290 NFRC
0.23 NFRC 0 New IWC 6200 AlumA-ow-E Whole House
21
Window 4.01
0.290 NFRC
1 0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House
22
Window 4.0
0.290 NFRC
0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House
23
Window 4.0
0.290 NFRC
0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House
24
Window 64.0
0.290 NFRC
0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House
25
Window 8.0
0.290 NFRC
0.23 NFRC 0 New IWC 6200 Alum/Low-E Whole House
26
Skylight 24.0
0.700 NFRC
0.39 NFRC 270 New Double Whole House
(1) Ll -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t Wd
Ove hang Left Fin Right Fin
Len H t LExt I RExt Dist I Len H t Dist Len H t
17
Bug Screen
0.76
2.0 2.0 2.0 0.1 2.01 2.0
18
Bug Screen
0.76
8.0 8.0 20.0 0.1 20.0 20.0
19
Bug Screen
0.76
4.0 2.0 2.0 0.1 2.0 2.0
20
Bug Screen
0.76
3.0 3.0 2.0 0.1 2.0 2.0
21
Bug Screen
0.76
2.0 2.0 2.0 0.1 2.0 2.0
22
Bug Screen
0.76
2.0 2.0 2.0 0.1 2.0 2.0
23
Bug Screen
0.76
2.0 2.0 2.0 0.1 2.0 2.0
24
Bug Screen
0.76
8.0 8.0 12.0 0.1 12.0 12.0
25
Bug Screen
0.76
4.0 2.0 2.0 0.1 2.0 2.0
26
None
1.00
Ener Pro 5.1 by Ene Soft
User Number: 2655
RunCode: 2013-05-13714:13:52 ID: Page 8 of 13
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF -1 R
Project Name
Stockdale Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ' ❑ Existing+ Addition/Alteration
Date
5/13/2013
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Existinq Altered Removed Volume
Year Built
Mole House Whole Houser
2,640
26,400
Totals 1 2,6401 01 01 01
1
HVAC SYSTEMS
System Name Qty. I Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type
Status
Whole House 2 1 Central Furnace
80% AFUE Split Air Conditioner 15.0 SEER Setback
New
HVAC DISTRIBUTION
System Name Heating
Duct
Coolin Duct Location R -Value
Ducts
Tested? Status
Whole House Ducted Ducted Attic, Ceiling Ins, vented 8.0
m
New
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
A. 0. SMITH FPS -50-224
2
Small Gas
All Pipes Ins
43,000
50
0.62
n/a
n/a
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
o
co
v
¢ —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qt .HP
Plenum Outside Buried
Ene Pro 5.1 by Ener Soft User Number: 2655
RunCode: 2013-05-13T14:13:52 ID:
Pae 9 of 13
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 " MF -1 R
Project Name ' • - f •
Date
1
5/13/2013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 " MF -1 R
Project Name ' • - f •
Date
Stockdale Residence
5/13/2013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk(*) below: This Mandatory Measures Summary shall be, incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures: '
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.:
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the ,
installation of a Cool Roof is specified on the CF -1 R Form. -
'§l 50 a :Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. '
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. ;
*§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
§150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.'
1 50 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration..
Fireplaces, Decorative Gas Appliances and Gas Log Measures: '
150 e 1 A: Mason or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. .'
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air-intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing S -stern Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units,and High -Rise residential occupancies meet the air release
.valve, backflow pr6vention, pump isolation valve, and recirculation loop connection requirements of §113(6)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
'(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters: -
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. '
§150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). '
§150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
With insulation having an installed thermal resistance of R-12 or greater. *v
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R=16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank. . .
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire,length of
recirculatinq sections of hot water pipes are insulated per. Standards Table .150-13.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A. -
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
§1500)k Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance and wind.
§150(j)3A: Insulation forchilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
'
conditioned space.
150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Ratin •and Certification Corporation
d13
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-05-13T14:13:52 ID: Page 10 of
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Stockdale Residence
5/13/2013
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause de radation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
§150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-05-13T14:13:52 ID: Page 11 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name b
Date
Stockdale Residence
5/13/2013
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceilin .
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be hi h efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130 131 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2 013-0 5-13 714:13:52 ID: Page 12 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Stockdale Residence
Date
5/13/2013
System Name
Whole House
Floor Area
2,640
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 1,084
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD--
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 70,000
26,126
2,448 644
23,803
Total Out ut Btuh 140,000
0
Output Btuh/s ft 53.0
1,508
1,170
Cooling System
0
0
Output per System 42,000
0
0 0
0
Total Output Btuh 84,000
0
2,448
0
Total Output Tons 7.0
1,508
1,170
Total Output Btuh/s ft 31.8
Total Output s tt/Ton 377.1
I 29,143
26,143
Air System
CFM per System
2,055
HVAC EQUIPMENT SELECTION
Airflow cfm
4,110
Day & Night INXA 660 GKA 61,828
9,947
140,000
140,000
Jan 1 AM
Airflow cfm/s ft 1.56
Airflow cfm/Ton 587.1
,
'Outside Air % 0.0 %
Total Adjusted System Output 61,828
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
9,947
Aug 3 PM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 70 OF r
Outside Air
0 cfm Supply Fan
4,110 cfm
70 OF
70 OF 105 OF
Heating Coil
105 OF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 78/63°F 78/63°F 55/54°F
c
Outside Air. •
0 cfm Supply I Fan Cooling Coil 55 / 54 OF
4,110 cfm
41.8% ROOM
78 / 63 OF 78/ 62 OF
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-05-13T14:13:52 ID:
Page 13 of 13
POST IN A CONSPICUOUS PLACE
Certificate of Occupancy
Community Development Department
This Certificate is issued pursuant to the requirements of Chapter 1 Section R110 of the
California Residential Code, certifying that, at the time of issuance, this structure was in
compliance with the provisions of the Building Code and the various ordinances of the City
regulating building construction and/or use.
BUILDING ADDRESS: 53-725 AVENIDA VALLEJO
Use classification: SINGLE FAMILY DWELLING Building Permit No.: 13-0094
Occupancy Group: R-3 Type of Construction: VB Land Use Zone: RL
Code Edition: 2010 Sprinkler Installed: YES Sprinkler Required: YES
Owner of Building: STOCKDALE, CHARLES D
Address: 50855 WASHINGTON ST, C217
City, ST, ZIP: LA QUINTA, CA 92253
____________ GREG BUTLER_________________ By: KIRK KIRKLAND
Building Official Date: MAY 30, 2014