Loading...
BRES2015-0245v Applicant:I I U Contractor: ADAM'S CONSTRUCTION AUG 19 Z�iS ADAM'S CONSTRUCTION Qum& VOICE (760) 777-7125O�i 7&495 CALLE TAMPICO EL SEG U N DO, CA 90245 D EL SEG U N DO, CA 90245 COMMUNITY DEVELOPMENT DEPARTMENT FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 8/19/2015 Application Number: BRES2015-0245 Owner: Property Address: 54575 AVENIDA VALLEJO PATRICK RYAN APN: 774281027 54575 AVENIDA VALLEJO Application Description: RYAN / BED & BATH ADDITION LA QUINTA, CA 92253 Property Zoning: Application Valuation: $28,008.00 Applicant:I I U Contractor: ADAM'S CONSTRUCTION AUG 19 Z�iS ADAM'S CONSTRUCTION 531 MAIN STREET #308 531 MAIN STREET #308 EL SEG U N DO, CA 90245 CITY OF IA QUINTA EL SEG U N DO, CA 90245 COMMUNITY DEVELOPMENT DEPARTMENT (310)227-0033 Llc. No.: 990098 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, ,and my License is in full force and effect. License Class: B License No.: 990098 Date: Contracto . OWNER -B ER D RATION I hereby affirm under penalty of p ry th am exempt from the Contractor's State License Law for the following rea on (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair . any structure, prior to its issuance, also requires.the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Divisio refrom of the Business and Professions Code) or that he or she is exempt theand the basis for the alleged exemption. Any violation of Section 7031.5 ny by aapplicant fo a permit subjects the applicant to a civil penalty of not more than five hundred dollars .($500).: 1 1 . (_J I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's . WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and.agree that, if I should become subject to the workers' compensation provisions of Section 3700 o e Labor Co I shall forthwith comply with those � provisions. Date: R_/-`�Applica WARNING: FAILURE TO SECURE WOR S' CO SATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER' 0 CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, .each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- fyentioned property for inspection purposes. Date: Signature (Applicant•or Age 00 DESCRIPTION ACCOUNT QTYr; AM OUNT PAID ; PAID:DATI _� �r _F .� . 0 $120.83 $171.14 ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $62.36 $0.00 # x -ref>d PAIDBY �� `' ' y ""'.. RECEIPT# CHECK# CLTD BY"' j;'" +.x:'METHOD $0.00 x. '= ^R,RECEIPTMETHOD CHECK#+ DESCRIPTION '-gY ACCOUNT QTYx <<; AMOUNT` PAID, DATE , , fix`' L r * rtPAID ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 $0.00 METHOD RECEIPT # �; CHECK # f CLTD BY a '; DESCRIP,TIONKf: .?.: ,z s t 'ACCOUNT. : s> QTY+ +` AMOUNT.` f ,� PAIDA, r PAID GATE ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $0.00 $171.14 { PAID BY RECP �✓ � CHECK # CLTD BY # x CLTD BY' .:;F 101-0000-42403 t" DESCRIPTION ACCOUNT ' QTY;'AMOUNT_' NTU ;� PAID PAID DATE ADDITION, FIRST 100 SF PC 101-0000-42600 2 0 $171.14 $0.00 ,f PAIDBY PAID BYE..RECE.I.P.T ,:RECEIPT#F 4;s-, # x CLTD BY' 101-0000-42403 ::..z. .CHECK Total Paid forADDITION: $371.73 $0.00 : ,' ACCOUNT l NTU -PAID*PAID DATEDESCRIPTIONx HOURLY PLAN CHECK - YES 101-0000-42600 2 $140.00 $0.00 ...... ,f PAIDBY METHOD x�`;M f ,:RECEIPT#F .� +CHECK# € CLTD BY Y DESCRIPTION . µ,,{ "� ACCOUNT 7 *QTY;" ` AIVIOUNTR{: ' PAID 'PAID. DAT HOURLY PLAN CHECK - YES 101-0000-42600 0.75 $52.50 $0.00 N PAID;.BY_, METHODS r: RECEIPT ¢ CHECK # s CLT.:. ECEIP .. _. ;1 � D BY Total Paid forBLDG CITY STAFF - PER HOUR: $192.50 $0:00 f"nDESC RIFTIONF', `' u Y, x ACCOUNT QTY ` AMOUNTkE PAID + PAID DATE a, e..; BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 SI s t4,iw PAID BYFMETIIOD , ti ; ;= "RECEIPT # CHECK # £ CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA: $2.00 $0.00 iDESCRIPTION' " r i '' ,; s g ACCOUNT AMOUNT 'rig + 'PAID PAID DATE'. SERVICES 101-0000742403 0 $24.17 $0.00 RAID BY Q ,X,.METHOD" ,q4:. 4. .": RECEIPT # -� • ° :� CHECK # :CLTD BY; ] DESCRIPTION x ACCOUNT l QTY -P:' I AMOUNT:: .. 'PAID a : -.s+ ... PAID. DATE �. ...... .. d SERVICES PC 101-0000-42403 0 $12.09 $0.00 ,PAID BY '= ^R,RECEIPTMETHOD CHECK#+ !CLTDBYV Total Paid for ELECTRICAL: $36.26 $0.00 �WDESCRIPTION� 4 = °i `, ;¢ i & ACCOUNT , Q AMOUNT:' 5a s' PAIDr xis IPAID .DATE, r ra f ' `DESC RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $0.00 VENT FAN �R tr PAID BYa ie ,_` eb .METHOD ; .., ,' K 4 RECEIPT # CHECK # {, s CLTD BY . PAID::BY `. METHOD y -RECEIPT # _ CHECK # CLTD BYE ' «DESCRIPTION , `� 'w' ...m[ w ... Y t e ¢ *ACCOUNT V QTYz �,• AMOUNT Y PAID t x PAIDDATE t '. DESCRIPTIONr.:'+ E `" RESIDENTIAL, FIRST 1,000SF,'PC 101-0000-42600 0 $47.86' $0.00 VENT FAN PC �..k�T. PAID BY" a� , rF, sA ; METHOD : , r °RECEIPT # CHECK # CLTD BY y , " PAID 6Y, t ;k F� ;b.METHOD RECEIPT # �; , y CHECK # CLTD BY Total Paid forELECTRICAL- NEW CONSTRUCTION: $192.89 $0.00 `.Y DESCRIPTION ,4 :; _; ACCOUNTFAIIIIOUNT' PAID" ;PAIDDATE 'DESCRIPTION;` APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.09 $0.00 ' FIXTURE/TRAP x'PAIf)'BY4=:' METHOD a s';RECEIPl # r° CHECK# ;"?, 'CLTDBY'. PAID BY �F s ; � -METHOD '° 'RECEIPT # r CHECK # CLTD BY' DESCRIPTION i'k, k 4. �2R L% £ ACCOWNT � 1 QTY - 6..' h .; AMOUNTS :'. PAID £ r$x I PA0DATE DESCRIPTION : _' 41 jr­ 'k` `- APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $4.83 $0.00 FIXTURE/TRAP PC PAID -BY g� _ ."" METHOD ° ` 'RECEIPT # ` g CHECK #.'CLT U BY t ' _ } ;yMETHOD & RECEIPT #y ' CHECK # CLTD BY f ' `DESC T AMOUNT. PIRIPTON PAID„DATE< VENT FAN 101-0000-42402 0 $12.09 $0.00 PAID::BY `. METHOD y -RECEIPT # _ CHECK # CLTD BYE ' t '. DESCRIPTIONr.:'+ E `" ;'-ACCOUNT-74 - QTY °' AMOUNTS x: r PAID Ei: `PAID DATE VENT FAN PC .101-0000-42600 0 $4.83 $0.00 " PAID 6Y, t ;k F� ;b.METHOD RECEIPT # �; , y CHECK # CLTD BY Total Paid forMECHANICAL: $33:84 $0.00 'DESCRIPTION;` AMOUNT PAID E; PAID .DATE ' FIXTURE/TRAP 101-0000-42401 0' $24.18 $0.00 PAID BY �F s ; � -METHOD '° 'RECEIPT # r CHECK # CLTD BY' DESCRIPTION : _' 41 jr­ 'k` `- .` ACCOUNT -w, ;QTY SAMOUNT PAID,PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $24.18 •$0.00 PAID 'Y + ' ' _ } ;yMETHOD & RECEIPT #y ' CHECK # CLTD BY DESCRIPTION :_,_ �` '° ACCOUNTQTY'' s AMOUNT & PAID ' ;. PAIDDATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 $0.00 gt. , �PAIDBYEp '-fw _> ' n. METHOD �' RECEIPT ,# �.. T.: CHECK # CLTD BY f - DESCRIPTIONS: „' :'ACCOUNT a QTY" ;:y AMOUNT?= PAID tr PAID .,DATE, WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 $0.00 PAID BY Fr Y „' a rMETHOD:RECEIPT # CHECK .# CLTD BY :. Total Paid forPLUMBING FEES: $72.54 $0:00 WD,- E ION TSCRT . , �a.. . QN- .!a MOUNT,�. a: Ddrx = ast PAI PAIDDATE... REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $0.00 PAID<BY ", a �z ` 0: k �: METHOD i � P .y RECEIPT # ,A. ., s t. 4x CHECK # `.; p•" :.f' 1 CLTD BYu: h...x r i .DESCRIPTION ;��+v .�,.any§ �? q i r: ACCOUNT +.� QTY= �. S� ��c AMOUNT,; �,x'-,"�� nX- PAID =w PAIDDATE>, REMODEL, FIRST 500 SF PC 101-0000-42600 0 $134.88 $0.00 k PAIDq}BY CHECK #4.;.: ' CLTD BY Total Paid forREMODEL: $184.19 $0.00 .DESCRIP,TION . c� ._.r �; _ A000UNT, � CITY AMOUNTr PAID�z t -PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $3.64 $0.00 71, PAID"BY` r"y a : ate, § METHOD zK x 3a >RECEIPT#�r _ , Y •.0 ' CHECK #"IIxY r CLT BYE. Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $3.64• $0.00 TOTALS:• • •• r-- Description: RYAN / BED & BATH ADDITION Type: BUILDING, RESIDENTIAL Subtype: ADDITION, Status: APPROVED Applied: 6/25/2015 EVA Approved: 8/18/2015 JJO Parcel No: 774281027 Site Address: 54575 AVENIDA VALLEJO LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA AT VALE LA QUINTA Block: Lot: 5 Issued: UNIT 28 'JIM JOHNSON Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: _ Valuation: $28,008.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 8/13/2015 Details: BED & BATHROOM ADDITION PER 2013 CRC CODES, RELOCATE EXISTING ELEC SERVICE 54 as 4 Applied to Approv 'AODITiONAL SITES Printed: Wednesday, August 19, 2015 4:02:15 PM 1 of 5 r CR?w1YSTrMS CFI120NOLOGYTYPE STAFF NAME ACTION GATE `� COMPLETION DATER NOTES t ,, - . tee_. 7 NOTE 'JIM JOHNSON 6/26/2015 7/15/2015 NOTE. JIM JOHNSON 8/13/2015 8/18/2015 PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 7/15/2015 7/15/2015 STRUC READY FOR CORRECTIONS. 7/14/2015 �. .,-RECEIVED-. _ - - -- - - PLAN CHECK COMMENTS FROM CONSULTANT PHILIP JUAREZ 8/17/2015 8/17/2015 APPROVED 08/17/2015 PER KATHRYN SAMUELS RECEIVED PLAN CHECK PICKED UP STEPHANIE KHATAMI 7/15/2015 7/15/2015 _ RESUBMITTAL. KAY HENSEL 8/13/2015 7/30/2015 RESUBMITTAL PHILIP JUAREZ 7/30/2015 7/30/2015 'AODITiONAL SITES Printed: Wednesday, August 19, 2015 4:02:15 PM 1 of 5 r CR?w1YSTrMS SENT TO PLAN CHECK PHILIP JUAREZ 7/30/2015 7/30/2015 INronMATION SENT TO YOUNG ENGINEERING . CONSULTANT . ... .. ­.z�DESCRIPTIOt ACCqUNT,.�.' j ",,�"AMOUNV` -p AID 'PAID DATE RECEIPT # CHECK' CALLED JONHN YOCUM TO INFORM HIM THAT PLANS ARE TELEPHONE CALL JIM JOHNSON 7/15/2015 7/15/2015 BY READY FOR CORRECTIONS 101-0000-42400 0 $62.36 _TPENDING CALLED JOHN TO ,' INFORM HIM PLANS ARE READY TO ISSUE TELEPHONE CALL F JIM JOHNSON 8/18/2015 ADDITIONAL 500 SF 8/18/2015 SCHOOL FEES . ..... . ... ... ..... .. 101-0000-42600 . CONDITIONS .. ... . ... .. CONTACTS `NAME TYPE. NAME'. ADE Cl STATE ' *PHONE FAX�E AIL APPLICANT ADAM'S CONSTRUCTION 53.1 MAIN STREET #308 ELSEGUNDO CA 90245 (951)283-0431 CONTRACTOR ADAM'S CONSTRUCTION 531 MAIN STREET #308 EL SEGUNDO CA 90245 (951)283-0431 OWNER PATRICK RYAN 54575 AVENIDA LA QUINTA CA 92253 (951)283-0431 VALLEJO ....... ..... . ,rINANCIAL INronMATION . ... .. ­.z�DESCRIPTIOt ACCqUNT,.�.' j ",,�"AMOUNV` -p AID 'PAID DATE RECEIPT # CHECK' 'METHOD 0 PAI .M BY ADDITION, EA 101-0000-42400 0 $62.36 $0.00 ADDITIONAL 500 SF ADDITION, EA 101-0000-42600 0 $17.40 $0.00 ADDITIONAL 500 SF PC ADDITION, FIRST 100 SF, 101-0000-42400 -0 $120.83 $0.00 ADDITION, FIRST 100 SF 101-0000-42600 0 $171.14 $0.00 PC Total Paid forADDITION: $371.73 $0.00 HOURLY PLAN CHECK - 1010000-42600 2 $140.00 $0.00 YES ,HOURLY PLAN CHECK - 101-0000-42600 0.75 $52.50 $0.00 YES • Total Paid for BLDG CITY STAFF - PER HOUR: $192.50' $0.00 Printed: Wednesday, August 19, 2015 4:02:15 PM 2 of 5 cffw1yST[mS `6ikkwTio 777777777 -77 - 7�, � %4.-, ';`PAI 'RECEIPT 'BY pF N J. J OU.K1T 4 �qc .-QTY i�'-AmC) NT�--4� U PAID DATE' # ;'CHECK M THOD-,;, E -P ID BY Z- 7, F BSAS.SB1473 FEE 101-0000-20306 0 $2.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $2.00 $0.00 BSA:' SERVICES 101-0000-42403 0 $24.17 $0.00 SERVICES PC 101-0000-42403 0 $12.09 $0.00.- Total Paid foiELECTRICAL: , $36.26 $0.00 RESIDENTIAL, FIRST 101m0000-42403 0 $145.03 "$0.00 1,OOOSF RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $0.00 1,000SF, PC Total Paid for ELECTRICAL - NEW CONSTRUCTION:, $192.89 $0.00 APPLIANCE - 101-0000-42402 0 $12.09 $0.00 REPAIR/ALTERATION APPLIANCE 101-0000-42600 0 $4.83 $0.00 REPAIR/ALTERATION PC VENT FAN 101-000042402 0 $12.091 $0.00 VENT FAN PC 101-0000-42600 0 $4.83 $0.00 Total Paid for MECHANICAL: $33.84 $0.00 FIXTURE/TRAP 101-0000-42401 0 $24.18. $0.00 ri)(TURE/TrtAP PC 193 9009-42600 - 0" 424.30. to nn WATER SYSTEM 101-0000-42401 0 $12.09 $0.00. iNST/ALT/REP 'WATER SYSTEM 101-0000-42600 '0 $12.09 $0.00 INST/ALT/R EP PC Total Paid for PLUMBING FEES: $72.54 $0.00 REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 --. $0.00-1 -T Printed: Wednesday, August 19, 2015 4:02:15 PM 3 of 5 Cffw.1ySTrmS .RETbRNED REMARKS REVIEWER:;� SENT DATE DUE DATE -NOTES - NON-STRUCTURAL- JIMJOHNSON 6/25/2015 6/25/2015 IPYA REMODEL, FIRST SOO SF 101-0000-42600 0 $134.88 $0.00 KATHRYN PC 7/9/2015 7/14/2015 REVISIONS REQUIRED STRUCTURAL - 1 WK Total Paid forREMODEL: $184.19 $0.00 SMI - RESIDENTIAL 101-0000-iO3O8 0 $3.64 $0.00 Total Paid fo"rSTRONG MOTION INSTRUMENTATION SMI: $3.64 $0.00 .RETbRNED REMARKS REVIEWER:;� SENT DATE DUE DATE -NOTES - NON-STRUCTURAL- JIMJOHNSON 6/25/2015 6/25/2015 6/26/2015 REVISIONSREQUIRED KATHRYN 6/25/201S 7/9/2015 7/14/2015 REVISIONS REQUIRED STRUCTURAL - 1 WK 1ST PLAN CHECK SUBMITTAL, CALCS SAMUELS KATHRYN 7/30/2015 8/13/2015 8/17/2015 READY FOR APPROVAL STRUCTURAL - 2 WK SAMUELS nnNpINFOR -Attac rneht Type,'_-' CREATED,�n. E7� 7­ DESCRIPTION:' A S U B D I R ABLED 7 _ETRAKILEN 54-575 AVENIDA 54-575 AVENIDA DOC 6/26/2015 JIM JOHNSON 0 VALLEJO.docx VALLEJO.docx DOC .8/13/2015 JIM JOHNSON SCHOOL FEES BRES2015- SCHOOL FEES BRES2015- 0 0245.pdf 0245.pdf 1ST REVIEW - NEW.CITY TRANSMITTAL DOC 7/14/2015 KATHRYN SAMUELS STRUCTURAL BRES 2015-0245 0 TRANSMITTAL (ist).pdf 1ST REVIEW - DOC 7/14/2015 KATHRYN SAMUELS STRUCTURAL BRES 2015-0245 KS 0 (ist).doc COMMENTS 2ND REVIEW - NEW CITY -TRANSMITTAL DOC 8/17/2015 KATHRYN SAMUELS STRUCTURAL BRES 2015-0245 0 TRANSMITTAL (2nd).pdf B'" # City of La Quinta Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta; CA 92253 - (760) 777-7012. v 2`l Building Permit Application and Tracking Sheet Permit # $(�tS 2.(j t5 Project Address: Owner's Name: A. P. Number: Address: Legal Description: City-, ST, Zip:.Qu tLAAo 3 Contractor: <o Telephone:hone: CIS/ O Address: Project Description: City, ST, Zip: Telephone: P o e.• 3 a a17 00 State Lie. # : q Arch., Engr., Designer: City Lie. #cRonga, Address: City, ST, Zip: Telephone: hone: <: Construction ccu Type: e: Occupancy: Y P P Y• to i S to Lie. #: ProJ'ecthP e (circle one • New =Alter ReP ai r Demo Name of Contact Person: Q AA Sq. Ft.: #Stories: I #Units: Telephone # of Contact Person: Estimated Value of Projec . APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reed TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cafes. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan god Review, ready for correction /issue I g Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees CERTIFICATE OF COMPLIANCE m Desert Sands Unified School District ��o 4 47950 Dune Palms Road ¢ BERMUDA DUNES r Date 8/19/15 La Quinta, CA 92253 � RANCHO WELMIRLS (� INDIAN WELLS �r M DESERT No. 31904 (760) 771-8515 ��s LA IND OT^ y73_ �Q � Owner Ryan APN # 774-281-027 Address 54575 Avenida Vallejo Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 54575 Avenida Vallejo 140 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 140 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - John Yocum Check No. Bank Name/Recipient of Certificate Telephone 310-227-0033 Funding Exempt By Dr. Gary Rutherford Superintendent Fee collected /exempo'd by Signature IV Payment Recd i v •. e � � $o-oo ^.`v a Aver/Unber�- lJ�cn yf�'. • . NOTICE: Pursuant to Government Code Section $6020(d)(1)tthis will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the da on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another pu icgn'tity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting Y .w Letter of Tra_nsmi taf, -To: City"of L'a Quinta' Today's Date. 8=1.7-15 • { : Ft 78-495 Calle Tampico City Due Date: 8-13=15 La Quinta, CA 92253 Project Address: 54575.Avenid6 Vallejo Attn: Kay : Plan Check #: BRES 20.15-0245 Submittal: Sl 4 t .2nd. ❑ ;55th, ❑ 3d, `❑ Other. We are forwarding: ® By Messenger E]"By Mail (Fed Ex or -LIPS)-,, _ ElYour Pickup r, Includes: # Of-, Descriptions. Includes: # Of, Descriptions: ' . „Copies: Copies: ❑, Structural Plans ® 1 Revised,.'Structural .Plans ' ® 2 Structural Calculations ❑ Revised Struct. Calcs Truss Calculations Floor ❑ ElRevised.Truss a and Roof ❑ Soils -Report' '. t. " p Revised SoilsReport'" Structural ComLi ment st/ ® 2 ' ❑ Approved Structural Plans M Responses - . ® 1 Redlined Structural. Plans ❑ approved Structural Calcs '❑ : Redlined.Structural Cal,cs Approved Truss Calcs.. ❑ Redlined Truss Calcs ',. A roved'Soils•Report .. - ❑ Redlined SoilsReports e ❑.: er: ; • ,' AU &1 % Comments: Structural content is approvable: GIT t Q INTACodha�; x 3 t ELOPME0r If you have any questions;` please call. ' Time =.75 HR This 'Material Sen,,t fo.r: . s ❑. Your Files ® Per Your Request ° -- ❑ Your Review ❑ Approval .. ' ❑ Checking ❑ At the request of: Other: ❑ .. r BY:. Kathryn Samuels • ` Palm Desert Office: ® .(760),772-5107 Other . i' BUILDING ENERGY ANALYSIS REPORT] [DA TY OF LA QUINTA ILDING & SAFETY DEPT, APPROVED PROJECT: FOR CONST CTION Ma t Bedroom & Bath Addition s g I k_By 54575 Avenida Vallejo La Quinta, CA 92253 Project Designer: Coronado Design Group 68-335 Marina Rd Cathedral City, CA 92234 o (760) 408-0972 Report Prepared bT Ricardo Aguilar CADD Works lnc. 31475 Calle Helene Thousand Palms, CA 92276 (760),272-5183 CARD=Wgriicr-lNt- -�Q_�� 'T;tie.i4�nc �c orts ERECEIVED- Job Number: JUL 3 02015 54575 CITY OF LA QUINTA Date: COMMUNITY DEVELOPMENT 7/29/2015 The EnergyPro computer program has been, used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. EnergyPro 6.6 by EnergySoft User Number. 5999 ID: 54575 w I '• ` 'CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Remodel Calculation Description: Title 24 Analysis Calculation Date/Time: 17:33, Wed, Jul 29, 2015 Input File Name: RYAN -54575 Avenida Vallejo-T24-2.xml CF1 R -PRF -01 Page 1 of 8 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Residence Remodel 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDVfft2-yr) 03 Project Location 54575 Avenida Vallejo Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 1822 15 Number of Zones 2 16 Slab Area (ft2) 1822 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (f42) N/A 21 Glazing Percentage (%) 10.9% COMPLIANCE RESULTS 01 Building Complies with Computer.. Performance 02 This building incorporates featur6 that require field testing`'and/or�4erification.by ajcertifidd HERS rater,underthe supervision of a CEC-approved HERS provider. 03 This building incorporates one o� Mi re Special Feafu�es shown below � q —V ,.. ' « 4"'4 1Y IE tib° Xa; IFA Registration Number: 215-N0197745A-000000000-0000 Registration Date/Time: 2015-07-29 17:41:40 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-29 17:35:27 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDVfft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.04 0.50 0.54 51.9% Space Cooling 109.22 108.20 1.02 0.9% IAQ Ventilation 1.18 1.18 0.00 0.0% Water Heating 12.60 12.04 0.56 4.4% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 124.04 121.92 2.12 1.7% Registration Number: 215-N0197745A-000000000-0000 Registration Date/Time: 2015-07-29 17:41:40 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-29 17:35:27 ' CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Remodel Calculation Description: Title 24 Analysis Calculation Date/Time: 17:33, Wed, Jul 29, 2015 Input File Name: RYAN -54575 Avenida Vallejo-T24-2.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cathedral Ceiling HERS FEATURE SUMMARY CFI R -PRF -01 Page 2 of B The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • -- None -- HVAC Distribution System Verifications: • -• None -- a Domestic Hot Water System Verifications: • -- None --, ENERGY DESIGN RATING:- This is the sum of the annual TDV energy;consumption for3energy usetcomponentsincluded in the performance compl ance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated'by'Title 24, Parrt 6,(such as -domestic. apphances,and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. " Reference-Erlergy Use Energy. Design Rating Margin Percent Improvement Total Energy (kTDVIf2-yr)* '173.57,- Z 171:45 2.12 1.2% • includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Residence Remodel 1822 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone Ex Conditioned • HVAC Systeml 1700 8 DHW Sys 1 Zone New Conditioned HVAC Systeml 122 8 DHW Sys 1 Registration Number: 215-No197745A-000000000-0000 Registration Date/Time: 2015-07-29 17:41:40 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-29 17:35:27 t 'CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Remodel Calculation Date/Time: 17:33, Wed, Jul 29, 2015 Calculation Description: Title 24 Analysis Input File Name: RYAN -54575 Avenida Vallejo-T24-2.xml CFI R -PRF -01 Page 3 of 8 OPAQUE SURFACES 01 VZ' 0.2 `_ ;� � � `' �-r•-03 � � � • 04 05 04 06 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ftZ) Window & Door Area (ftZ) Tilt (deg) Exterior Wall - S Zone Ex R-13 Wall 180 Front 196 48 90 Exterior Wall - W Zone Ex R-13 Wall 270 Left 160 25 90 Exterior Wall - E Zone Ex R-13 Wall 90 Right 352 76 90 Exterior Wall - N Zone Ex R-13 Wall 0 Back 316 35 90 Roof 2 Zone Ex . R-38 Roof Attic Radiant 850 Roof 3 Zone Ex R-38 Roof Attic Radiant 850 Exterior Wall - S 2 Zone New R-13 Wall 90 Right 40 90 Exterior Wall - W 2 Zone New R-13 Wall 270 Left 196 51 90 OPAQUE SURFACES — Cathedral Ceilings/ - 01 VZ' 0.2 `_ ;� � � `' �-r•-03 � � � • 04 05 04 06 07 08 09 10 11 Name Zone ,� -1 • Type s Orlentatlo„ .-,,,� n } E .. � rte.., Area;(ft?' 3 4 Sk II ht Area z y 9 "-'( �"(ft2) Roof Rise ; ; (x in 12) t $xa _, Roof Pitch F B F Roof Tilt (deg) Roof Reflectance Roof Emlttance Framing 9 Factor Roof Zone New;'!, 'R-38 Roof Flat Left T22 0 10.5 i 0.04 2.39 0.1 0.85 0.07 ATTIC V 1 F 01 02 03 04 OS 1 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Zone Ex Attic RoofZone Ex Ventilated 4 0.1 0.85 Yes No Registration Number: 215-N0197745A-000000000-0000 Registration Date/Time: 2015-07-29 17:41:40 HERS Provider: - CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-29 17:35:27 V • •CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Remodel Calculation Date/Time: 17:33, Wed, Jul 29, 2015 Calculation Description: Title 24 Analysis Input File Name: RYAN -54575 Avenida Vallejo-T24-2.xml CF1 R -PRF -01 Page 4 of 8 WINDOWS Jr� � I I It A\ It. 4 ar 01 #r=F'' 02,*$r t.- A 1.--.. i7"">' r- t"'b "9 f F 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) MUltlpli er Area (ft2) U -factor SHGC Exterior Shading Window Window Exterior Wall - S (Front -180) ---- ---- 1 12.0 0.45 0.40 Insect Screen (default) Window 2 Window Exterior Wall - W (Left -270) ---- ---- 1 16.0 0.45 0.40 Insect Screen (default) Window 3 Window Exterior Wall - W (Left -270) ---- ---- 1 9.0 0.45 0.40 Insect Screen (default) Window 4 Window Exterior Wall - E (Right -90) ---- ---- 1 32.0 0.45 0.40 Insect Screen (default) Window 5 Window Exterior Wall - E (Right -90) ---- - 1 20.0 0.45 0.40 Insect Screen (default) Window 6 Window Exterior Wall - E (Right -90) ---- ---- 1 24.0 0.45 0.40 Insect Screen (default) Window 7 Window Exterior Wall - N (Back -0) ---- ---- 1 16.0 0.45 0.40 Insect Screen (default) Window 8 Window A Exterior Wall - N (Back -0) --- --- 1 3.0 0.45 0.40 Insect Screen (default) Window 9 Window :. Exterior Wall - N (Back -0) ---- ---- 1 16.0 0.45- 0.40 Insect Screen (default) Window 10 Window r� 'd tt Exterior Wall - W 2 (Left -270) ---- ---- 1 24.0' 0.32 0.25 Insect Screen (default) French Door Window, s- -. S-LLtit 6rior Wall, -W 2 (Left -270) -� - ---- --- 1 18.0 0.32 0.25 Insect Screen (default) Window 11 Window ,-,Exterior Wall- W2 (Left270) 1 9.0 0.32 0.25 Insect Screen (default) DOORS Jr� � I I It A\ It. 4 ar 01 #r=F'' 02,*$r t.- A 1.--.. i7"">' r- t"'b "9 f F 1A`"ti R" 1 03 04 Name` s y"° " '."'e Side of Buildi g "' ` " Area (ft2) U -factor Door Exterior Wall - S 18.0 0.50 Door 2 Exterior Wall - S 18.0 0.50 4 Registration Number: 215-N0197745A-000000000-0000 Registration Date/Time: 2015-07-29 17:41:40 HERS Provider: CaICERT.S Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFSR-07082015-744 Report Generated at: 2015-07-29 17:35:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Remodel Calculation Description: Title 24 Analysis Calculation Date/Time: 17:33, Wed, Jul 29, 2015 Input File Name: RYAN -54575 Avenida Vallejo-T24-2.xml CF1 R -PRF -01 Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 �' Area (ft -2p Peri ete (ft) Edge InsulR-value &Depth Carpeted Fraction Heated Slab -on -Grade Zone -Ex 't-1 It K Z>1700 .f-*, Total Cavity Winter Design Slab -on -Grade 2 Zone New Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofZone Ex Attic Roofs Wood Framed Ceiling in. O.C. none 0.633 • Roofing: 5 PSF (Normal Gravel) • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Exterior Finish: Wood R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below - Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic Radiant attic) ti Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 • Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board /-, • Cavity / Frame: R-38 / 2x12 • Roof Deck: Wood Siding/sheathing/decking R-38 Roof Flat Cathedral -Ceilings' (Wood Framed Ceiling 2x12 @ 24 in. O.C. R 38 0.029 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS �`. , s` _ _ 01 02 01 :r;f r" . X02 jje' 9 03 X044fk r�.t 05 06 07 Name °�Zorie �' Area (ft -2p Peri ete (ft) Edge InsulR-value &Depth Carpeted Fraction Heated Slab -on -Grade Zone -Ex 't-1 It K Z>1700 .f-*, "{,,,,,jf �t6ti t None 1 No " Slab -on -Grade 2 Zone New 122 58 None 1 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Required Not Required Not Required -- WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/1 DHW Standard DHW Heater 1 1 .0% Registration Number: 215-No197745A-000000000-0000 Registration Date/Time: 2015-07-29 17:41:40 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-29 17:35:27 'CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Remodel Calculation Description: Title 24 Analysis Calculation Date/Time: 17:33, Wed, Jul 29, 2015 Input File Name: RYAN -54575 Avenida Vallejo-T24-2.xml CF1 R -PRF -01 Page 6of8 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.62 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 --- --- Distribution Name :Heat Pump System 1:Air Distribution System p ` 1:HVAC Fan 1:2 ,'Heat Pump'Heating and Cooling System' i+ 1.,`� = Heat Pump'System 1 SPACE CONDITIONING SYSTEMS ;.? ��• 01 .-- .. 02 03 04 05 06 ' Name Type Heating HSPF/COP Cap 47 Cap 17 Cooling SEER EER Zonally Controlled SC Sys Name -� w, •-Sy t m -Type : r Heating.Unit-Name` !: -� rw Cooling Unit Name Fan Name Distribution Name :Heat Pump System 1:Air Distribution System p ` 1:HVAC Fan 1:2 ,'Heat Pump'Heating and Cooling System' i+ 1.,`� = Heat Pump'System 1 No Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 f r, L--- t, ( J ( if ) HVAC - HEAT PUMPS °1 N ri r— 2.5 F v i R 01 02 03 04. 05 06 1 07 08 09 10 Name Type Heating HSPF/COP Cap 47 Cap 17 Cooling SEER EER Zonally Controlled Multlspeed Compressor HERS Verification Heat Pump System 1 SplitHeatPump I 9 I 6000060000 I F I1 13 F12 No No Heat Pump System -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Heat Pump System 1 -hers -cool Not Required Not Required Not Required Not Required Registration Number: 215-N0197745A-000000000-0000 Registration Date/Time: 2015-07-29 17:41:40 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-29 17:35:27 10ERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Residence Remodel Calculation Date/Time: 17:33, Wed, Jul 29, 2015 Page 7 of 8 Calculation Description: Title 24 Analysis Input File Name: RYAN -54575 Avenida Vallejo-T24-2.xml HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Existing (not specified) 6 Attic None Air Distribution System 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 - 04 05 06 07 08 - Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Burled Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Not Required Not Required Not Required Not Required Not Required --- HVAC-FAN SYSTEMSy4 01 ''�. 02 03 04 Name -q f E� Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 ", , y,.Sirigle`Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION j,'':�" 0. F � f I I � � 1 f= N( i t i Name. H F _S Verified Fan Watt�DrawRequired Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Not Required IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) - HERS Verification SFam IAQVentRpt 48.22 0.25 Default 0 Required Registration Number: 215-N0197745A-000000000-0000 Registration Date/Time: 2015-07-29 17:41:40 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-29 17:35:27 -'CERTIFICATE OF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residence Remodel Calculation Description: Title 24 Analysis Calculation Date/Time: 17:33, Wed, Jul 29, 2015 Input File Name: RYAN -54575 Avenida Vallejo-T24-2.xml CFI R -PRF -01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Ricardo Aguilar Company: Signature Date: CADD WORKS INC 2015-07-29 17:41:40 Address: CEA/HERS Certification Identification (If applicable): 31475 CALLE HELENE , City/State/Zip: Phone: THOUSAND PALMS, CA 92276 (760) 272-5183 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under�the laws of the State of California: 1. 1 am eligible under Division 3 of the Business''and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design` featufes identifiad- .on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans'and specifications submitted to the enforcement,age ncy, for approval,with.,t s.building permit application. - Responsible Designer Name: i ._ .�_,. t _Re's' n:'ible esigner Sig.Nat&6 5 Ricardo Aguilar ;� ` ";`a sL I 1 t! f � Company: ,, CADD WORKS INC H ER Date Signed: 07 17:41:40 E 2015 29 Address: License: 31475 CALLE HELENE 5999 City/State/Zip: Phone: THOUSAND PALMS, CA 92276 (760) 272-5183 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-140197745A-000000000-0000 Registration Date/Time: 2015-07-29 17:41:40 HERS Provider: CeICERTS Inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-29 17:35:27 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed: regardless of the compliance aonroach used. Fxcenlions may annly. Review the resnective code sectinn for more infnrmatinn Building Envelope Measures: § 110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC), and infiltration that meets the requirements of §10-111(a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF1R. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § 150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §150.0(g)l: walls, vented attics and unvented attics with air -permeable insulation. § 150.0(g)2: In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of §150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). §150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8( . § 150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. § 150.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.06)lA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 150.00)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.06)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 1203- A. § 150.0(j)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandatory Measures Summary §150.00)2C: Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.06)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § 150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § 150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater, a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)l: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)l: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 18 IA, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints §150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. §150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not §150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § 150.0(m)l 1: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 622. Neither window operation nor continuous operation of §150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. § 150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting-, a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(6)1: Any Pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § 150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. § 150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. § 150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of §150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)1C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. § 150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of §150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of §130.5; and all other requirements in 150.0(k)2. §150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory, have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or ui below, and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically tum the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically tum the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches, and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § 150.0(k)9B: following requirements: i. Shall comply with §I50.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, § 130.0, § 130.21 § 130.4, § 140.7 and § 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. §150.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to §130.0(c). §150.0(k)ll: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in §110.9, §130.0, §130.1, §130.4, §140.6, and §141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of §150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of §110.10(b) through §I10.10(e). §110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)l: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. §110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric".