Loading...
04-4036 (SFD)Tedf 41 4 Q" BUILDING & SAFETY DEPARTMENT" P.O. Box 1504 .. (760).777-7012 78-495 CALLE TAMPICo FAX (760),777-7011 f. . LA QUINTA+", CALIFORNIA 92253 ^,INSPECTION REQUESTS (760) 777-7152 BUILDING PERMIT Application Number Property Address r, APN: Application description-, Property Zoning Application valuation 04-00004036 Date 5/10/04 5759 O TH VALLEY LN .762-250-009- - - DWELLING - SINGLE FAMILY DETACHED LOW DENSITY RESIDENTIAL 246685 Owner Contractor, GEYER DOUGLAS L OWNER 78512 NAPLES DR ,LA QUINTA CA 92253 -------------------------- Structure Information --- --- Pdi Y 1 1 2004 Cl" 01 .A QUINTA F iNAwCE DEPT: Construction Type ". . . . . TYPE V - NON RATED Occupancy Type . . . . DWELLG/LODGING/LONG <=10 Flood'Zone NON -AO FLOOD ZONE Other struct info. . . . . CODE EDITION 2001 CBC # BEDROOMS 3.00.. FIRE SPRINKLERS NO GARAGE - SQ. FTG. 965. &0 NUMBER OF UNITS 1.00 FIRST FLOOR SQ FTG 3982.00. Permit BUILDING PERMIT Additional desc Permit Fee 1154.00 Plan Check Fee 500.10 Issue Date Valuation 246585 Qty Unit Charge Per Extension BASE FEE 639'.50 .147.00 3.5000 THOU BLDG 100,001-500,000 514':50 Permit ... . MECHANICAL Additional desc Permit Fee . . . . 96.50 Plan.Check Fee 24.13 Issue Date, . . . . Valuation 0 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100.K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 •6.00 6.5000 EA MECH VENT FAN 39.00 1:00 6.5000 EAMECH EXHAUST HOOD 6.50 4 P.O. Box 1504 • VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: (4- 903-0 Date: Applicant: -S/?/" 6- /+!S f1teGNSrr=c7- Applicant's Mailing Address: Architect or Engineer: Architect or Engine is Address: N Z2S3 Lic. No.: ) BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class License No. Date Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property, am exclusively contracting with licenRd contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property o builds o improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. BA P.C. for this red n/ Date 5 � /cam cs` RKERW COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the fol win a orations: _ I have and will maintain a certificate onse t t self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit s issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number I certify that, in the performance of the work for which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that-jf that - I sh uld become subject to the workers' compensation provisions of Section 3700 of the Labor Code, 1 shall forthwith comply with those provisions. 'Date Applicant J � WARNING: AILURE TO SECURE WORKE 'C PE ION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSA O S ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under `/penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name LNZ7 Q Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. IAato co ply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the abovd property for inspection purposes. Date - /d�s� r Signature (Applicant or Agent): Page 2 Application Number . . . . . 04-00004036 Date 5/10/C4 - ------------------------------------------------------ Permit . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee 188.67 Plan Check Fee 47.17 Issue Date . . Valuation 0 Qty 'Unit Charge Per Extension BASE FEE 15.00 3982.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 139.37 965.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 19.30 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15..00 Permit . . . . PLUMBING Additional desc Permit Fee . . . . 304.50.. Plan Check Fee 76.13 Issue'Date .. . . . Valuation 0 Qty Unit Charge Per Extension BASE FEE 15.00 29.00 6.0000 EA PLB FIXTURE 174.00 1:100 15.0000 EA PLB BUILDING SEWER 15.00 10.00 6.0000 EA PLB ROOF DRAIN 60.00 1.100 7.5000 EA PLB WATER HEATER/VENT 7.50 1..00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 8.00 .7500 EA PLB GAS PIPE >=5 6.00 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Permit . . . . . . GRADING PERMIT Additional desc Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - 3982 S.F. PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL/SPA,. OR DRIVEWAY APPROACH. BUILDING PLAN CHECK FEE MANUALLY REDUCED BY $250 TO ACCOUNT FOR DEPOSIT RECEIVED 3/9/04 UNDER PREVIOUS Page 3 Application Number 04-00004036 Date 5/10/C4 Special Notes and Comments PERMIT SYSTEM. ----------------------------------------------------------------------------- - Other Fees . . . . . . . . . ART IN PUBLIC PLACES-RES 116.71, ' DIF COMMUNITY CENTERS-RES 97.00 DIF CIVIC CENTER— RES 366.00 ENERGY REVIEW FEE 75.01 DIF.FIRE PROTECTION--RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00' DIF,PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00' STRONG MOTION (SMI) - RES 24:66 DIF STREET MAINT FAC-RES 15.00 DIF TRANSPORTATION - RES 109$.00. Fee summary Charged Paid Credited Due Permit.Fee Total 1758.67 .00 .00 1758.67 Plan,Check Total 647.53 .00 .00 647.53 Other Fee Total 2621.38 .00 .00 2621.38 Grand Total 5027.58 .00 00 5027.58 08/17/2004 ,.15:51 7605640884 DENNIS WISH PAGE 01 Vemic S. 7#6d �£ August 15, 2004 Mr. Ed Randall City of La Quinta La Quinta, CA 92253 Sent by facsimile on 8/16/2004 I S"RUCTURAL ENGINEERING CONSULTANT 54-825 AV ENIDA BERMUDAS, LA QUINTA CALIFORNIA 92253 760,564.0(84 PHONE* DENNIS.WISH@VERIZON.NET 4� Regarding: Geyer Residence, 57-595 S'outA Valley lane (Lion's Gate), La Quiet a, CA. Dear Ed: I Can you please pass this letter on to the inspect- or_of the ait.-There bove-property_ and.let_mv know who is assigned to are two concerns `- -- - that Mr. Ceyer discussed with me from the framing inspection that the inspector performed. 1 have requested Mr. Geyer to make the correction as indicated below; I . Ref: Detail 3 on S1.5; The Hardy Panels at the front of the garage require straps to be installed vertically on each 4" column- to olumnto the beam above. This is a requirement of Hardy Frame and I have instt'ucted Mr. Geyer to install the straps. 2. Shearwalls 1 and 10 are installed with PHD holddowns. The holddowns are installed•above the plate to allow for a threaded coupler to be installed extending the length of the anchor bolt that was in;talled too deeply. ]Chis is not accoMing to tate Simpson catalog that requires the installation of a pre -deflected holddown to be flush to the plate. To correct this deficiency, a number of pressure blocks•where added between the bottom of the raised holddown and the mud -sill. This will help to develop the tension required by the holddown and also keep the bottom of the connector flush to the wood. These were the only two items that Mr. Geyer brought to my attention. Please feel free to contact me before 8/20/04 (1 will be leaving on vacation at this time) to discuss any issues you may have left to resolve. SinV.Wish DenPE ,fin Tc� Structural Engineering Consultant Z DENNIS S. WISH ' i0 NO -C-041260 (� EXP, r�3cl�Ii `'koFcAtaF�' i1 STRUCTURAL ENCINEeRING FOR • CUSTOM HOMES- REMODEL • CO►(PAERCIAL • LICHT MD1,4TRIAL • SOSMIC RETROFIT & REPAIR • UNRE1NFORCED MASONRY. RETAIMN61NALL5 S FOUNDATION -REPORTS: QAMAGC A55ESSMENT • NEW ROOF - INSURANCE CLAIM. 0ENN16 6. w16n P, C. HA.S BEEN A MEMBER OF THE STRUCTU tAL ENGINEERS ASSOCIATION OF SOUMERN CALIFORNIA SINCE 1983 .08[11¢2004 07:46 7605640884 DENNIS WISH PAGE 01 -DaartaS• ?(lid ��", August 10, 2004 t, �l_:ri 4nll City of La Quinta — Department of Building and Safety Via Faxsimile STRUCTURAL ENGINEERING CONSULTANT 54-625AVENIDA BERMUDAS. LA QUINTA CALIFORNIA 92253 760.564,0884 PHONE 0'208.361.5447 E -FAX w STRUCTURES®ENGINE ER. COM Regardbtgr Meyer Residence ISlo etural Obs rva", S7 S9S ---------------- goath,Valley lane I G1nn's Gate), Le QuI ita, CA. Dear Ed: ' �------- "F d'r In compliance with UBC Section 1702, a struchual observation was performed on the structure located at`57-595 S_ Valley lane; Lion's Gate, La Quinta CA 92253. The Observation was performed on this buildvig on Monday, August 9, 2004 at 6;30PM. An inspection was performed for the load path elements including; shear panel type and nailing, shearwall to roof connections, blocking, drag and strap connections, general framing (in conformance to conventional framing standards) and mechanical anchorage. from 4 Urdform Building Code SeqWo 1702— &nctural Observa ' Structural Observation shall be provided in Seismic Zone.3 or 4 when one of the following conditions exists: The structure is defined in Table 16-K as Occupancy Category I, II or III or, 2. The structure is required to comply with section 403, or 3. When so designated by the architect or engineer of record, or 4. When such observation is specifically required by the building official. The owner shall employ the engineer or architect responsible for the strut ural design, or another engineer or architm designated by the engineer or architect responsible for the structcural design, to perform structural observation as defined in Section 220. observed deficiencies shall be reperted in writing to the owner's representative, special inspector, contractor and the building official. The structural observer shall submit to the building official a written statement that the site visits have been made and identifying any reported deficiencies which, to the best of the structural observers knowledge, have not been re::olved. ® The structure was found to be in conformance with the design details, framing plans and structural notes. The engineer responsible for the structural design has certified to the best of his knowledge that the building complies with the design, drawings and details for the lateral resisting system. ❑ Structural corrections have been made and confirmed by the engineer responsible for the structural desigar on This letter shall be submitted to the building official to certify that compliance with Section 1702 and Section 220 of the 1994 Uniform Building Code and previous deficiencies have been corrected. The engineer certifies to the best of his knowledge that the structural deficiencies have been resolved aid is in conformance with the intentions of the structural design, drawings and details. STRUCTURAL CCNOiTEEMND FOR - CUSTOM HOMES - REMOM - COMMERCIAL - MIT INIX) MAL - SCFSMIC RETROFIT d F4D%l R - UMRERI ORCED MASONRY - RETADOM MU.8& FOUNDATION - REPORTS: OAMAOE AMSSWNT- NEW ROOF - INSURANCE CLAIM - DBUIIs a. WISH P.E. HAS SEEN A MEMBER OF THE STRUCTOF AL EMINEERS ASSOCIATION OF SOUTHERN CALIFWUM SSICE 1 W3 08/11J2004 07:46 7605640884 DENNIS WISH PAGE 02 • Page 2 F ❑ The following deficiencies were identified. Corrections shall be made before framing inspecti6n is complete and final wrapping is approved. Where remedial design work is required, contact die Architect or Engineer of Record for design coordination and additional detailing necessary to correct the problem. Incomplete work shall be completed as shown on design drawings and a final Observation shall again be ordered to verify That deficiencies has been corrected to the best of his knowledge. of Structural Please allow 72 hours to schedule subsequent Structural Observation site visits_ All subsequent visits and remedial design corrections will be billed at an hourly rate of $ l 00.00 unless specifically noted. otherwise. Thank you for allowing me to represent your engineering needs. 'Si ly, QaOFESS/0, S ish PB �' DENNIS S. with S lural JFJj veering Consultant Na.c•o�1:eo C i �L Dot S01.01 1/09/99 9OFCA01 , STRUCTURAL ENOM ERINC FOR • CUBTOM. HOMES • REMODEL • CONMiERCUL • UaW INDUSTRIAL • aElBMIC RErRORT & REft i U1MWORCED MASONRY • PUAINMIo WAU•a m FOUNDATION REPORM OAMAOE ABBESBRENT. NEW ROOF • MURANCE CLAOA • OENNIS S. WMIH PS I1A8 BEEN A MBABER OF THE STRUCTURAL ENOOEERS AMOCIATTON OF BOUTM�(M CALFORMA ONCE 1983