Loading...
12-0389 (AR)P.O. BOX 1504 ' 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: X12-0 000389r ti Property Address: 57595 SOUTH VALLEY LN APN: 762-250-009- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 42097 T4ht. 4 4 Q" .Applicant: Architect -or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: A -B n License No.: 913666 *ate: Q-1 2- -1 Z- Contractor: G ' L�YC L7 Oi✓ 7i 4 Ll Z_ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business -and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business. and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: -' (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not. intended or offered for'sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). - 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an ownerof property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the. Contractors' State License Law.). (_ ) I am exempt under Sec. , B.&P.C.•for this reason ` Date: Owner: CONSTRUCTION LENDING AGENCY ` I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the - work for which this permit is issued (Sec. 3097, Civ. C.). r- Lender's Name: Lender's Address: f LQPERn1IT 4--r - VOICE (760) 7 FAX (760) 777-7011 INSPECTIONS (760) 777-7153. Date: • 9/12/12 Owner:. MAKSIMOUS,HANI KAMAL M & VIVIA 57595 SOUTH VALLEY LN LA QUINTA, CA 92253 D e p Contractor: E G S GENERAL CONTRACTOR MEP .121012 ' 5792 CHIQUITA LANE' SAN BERNARDINO, CA 92404 C1T_'OF(ZA ,gQU1Al (909) 991-7630 RATANC I Lic. No.: 913666 OPT < WORKER'S COMPENSATION DECLARATION I hereby affirm under -penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for. the performance of the work for which this permit is issued. My workers' compensation insurance carrier. and policy number are: Carrier CA INS CO Policy Number 468503290101 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: 1E'jtA4F,ti�r,✓Tim%eLr, -I- WARNING: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND , DOLLARS ($100,000). IN ADDITION TO'THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT. _ IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1-. Each person upon whose behalf this application is made, each person at whose request and for - whose benefit work is performed .under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being, performed under or following issuance of this permit. 2. Any permit issued as•a result of this applicationbecomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject. permit to cancellation. -I'certify that I have read this application and state that the above information is correct. Iagree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of.this county to enter upon the above-mentioned property for inspection purposes. Xate: Signature (Applicant or Agent): Z_ Application Number . . . . . 12-00000389 -----= Structure'Information 521SF ADDITI6N/VB/RES-3/CLASS A -FR [ENG] ----- Other struct info . . . . . CODE EDITION 2010 FLOOD ZONE NO ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 521.00 Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 369.00 Plan Check Fee 239.85 Issue Date . . . . Valuation 42097 Expiration Date 2/25/13 Qty Unit Charge Per Extension BASE FEE 252.00 18.00 6.5000 ---------------------------------------------------------------------------- THOU BLDG 25,001-50,000 117.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 33.24 Plan Check Fee 8.31 Issue Date' Valuation . . . . 0 Expiration Date 2/25/13 Qty Unit Charge Per Extension BASE FEE 15.00 521.00 .0350 ------------------------------------------------------------------------- ELEC NEW RES -' 1 OR 2 FAMILY 18.24 Permit . . . MECHANICAL 'Additional desc . Permit Fee . . . . 19.50 Plan Check Fee 4.88 .Issue Date Valuation . . . . 0 Expiration Date 2/25/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 ---------------------------------------------------------------------------- EA MECH VENT INST/ DUCT ALT 4.50 Permit . . . PLUMBING Additional desc Permit Fee 27.00 Plan Check Fee 6.75 Issue Date . . . Valuation . . . . 0 Expiration Date 2/25/13 Qty Unit Charge Per Extension BASE FEE 15.00 LQPERMIT• LQPERMIT . Application Number 12-00000389 Permit . . . . PLUMBING Qty Unit Charge, Per Extension 2.00 6.0000 EA PLB ROOF DRAIN 12.00 ------------------------------------------------------------- Special Notes and Comments 521SF ADDITION/VB/RES-3/CLASS A -FR [ENGINEERED] PLANS APPROVED WITH . COMMENTS - THIS PERMIT DOES NOT INCLUDE ALTERATIONS TO.THE EXISTING DWELLING. 2010 CALIFORNIA BUILDING CODES. August 29, 2012 9:49:10 AM AORTEGA --------------------------------------------------------------- Other Fees . . . .•. . . . . BLDG STDS ADMIN (SB1473) 2.00 ENERGY REVIEW FEE •23.99 STRONG MOTION (SMI) - RES 4.21 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- Permit Fee Total 448.74 .00 ---------- .00 448.74 Plan Check Total 259.79 .00 .00 259.79 Other Fee Total 30:20 .00 .00 30.20 Grand Total 738.73 .00 .00 738.73 LQPERMIT . u Bin. # . ::. Crty of. Buikffng or Safety Division P.O. Box. 1.5,�78-495 Gaffe Tampico La.Quinta, CA 92253 - (760) 7'77-7012 Building Permit Application and Tracking Sheet Permit # Project Address: Jew 7 S t S Owner's Name:. A- P. Number. 7,9 Z -ZSR •- 6,61 Address: S 7.S'`t S S4 ci 1 �%–"��.•s� Legal Description: tti City. ST, Zip: (R 22S �. Contwtor. Telephone: %/.rt 74' 7— Address: SCA Project Description: 2 0. . City, ST, Zip: Telephone: State Lia #: City Lie. #, Arch., Eng., Designer. Address:A4 VA City., ST, zip: � 0 _ . � . Telephone: Construction Type: _ Occupancy: State Lie. #: Project type (circle one): New Add'n Alter Repair. Demo Name of Contact Person: �S` oa`S Sq. Ft.: #Stories: # Units: Telephone # of Contact Person:' 76 --.4? (y Q 76 7�d Estimated Value of Project L9,000 APPLICANT: DO. NOT WRITE BELOW THIS UNE !R Submittal Req'd Recd TRACMG PERMiTFEES Pian Sets Plan Check submitted Item Amount Structural Calm Reviewed, ready for corrections Plan Check Deposit. . Truss Cales. Called Contact Person S Plan Check Balance Title 24.Cales. Plans picked up Constriction Flood plain plan Plans resubmitted.. echaracal Gtadiag plan r Review, ready.. rec o asu.i Q/ Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up t/ S.M.I. . H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 7i° Review; ready f tree ue $ Developer Impact Fee Planning Approval. w. Called Contact Person ,9 Pub. Wks. Appr Date of permit issue School Fees LM Total Permit Fees &Ali f b� i V�- IJ5'r W-1 slip twq- - Corn' *t, 1-7 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (7 60) 398-5909 — Fax (760) 398-1224 Project Name: _ Owner's Name: Project Address: This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVELTWOAMOUNT: MITIGATION AMOUNT: I COMM/IND.AMOUJT: DATE: RECEIPT: CHECK #: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Mr. & Mrs. Maksimous 57-595 South Valley Lane, La Quinta, CA 92253 Project Description: Addition to Existing Dwelling APN: 762 250 009 Tract #: Type of Development: [ Residential RN Commercial of Building Area: 521 Date: August 30, 2012 - Phone No. (760) 861-7670 Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: �� cJ D'Signature: 1 SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Gov. Code 65995 Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement N�o-te Number of Sq.Ft. Amount per Sq.Ft. Amount Collected 521 $3.20 $1667.20 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: " Marcela Valdez, Construction Analyst Signature: Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a writ notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the iition of tYese Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any oilier requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificat: of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, ane up to three (3) such extensions may be granted. 1 .::a�tliicl`�i: Ufa;>r.c;rtiti.Iltc a I Irll i.uu:e frr=n updrlie l ..'s -;.<Iii: 11/2010 SOUTH VALLEY GROUP, INC. LION'S GATE HOMEOWNERS ASSOCIATION do J & W. Mana P.O. Box 1398gement Co. Palm Desert, CA 92261 (760)568-0349 FAX (760) 346-4349 E-mail: jandwmgmt@aol.com April 23, 2012 Hani Maksimous ' Vivian Maksimous 57-595 South Valley Lane La Quinta, CA 92253 Dear Property Owner: Please be advised the Architectural Review Committee of Lions Gate Homeowners Association has approved your request.for room remodel extension at your home on South Valley Lane in La Quinta. This approval should not be considered a building permit. All necessary approvals and permits must be obtained from the City of La Quinta Building &.Safety Department before any construction begins. All rules and regulations pertaining to construction must be adhered to during course of construction. G If you have any questions, please call me. , t k Sincerely, Jim McPherson CommunityManager' } 71=,780 San Jacinto Dr: Ste. E2; Rancho Mirage,, Ca. 92270. ph: (.760) 834-8860 fax (760) 834-8861 Letter of Transmittal To: City of La Quinta Today's Date: 8-2-12 78-495 Calle Tampico City Due Date: 8-3-12 La Quinta, CA 92253 Project Address: 57-595 South Valley Lane Attn: Kay / AJ Plan Check #: 12-309 Submittal: ❑ 1st ❑ 4 t ® 2nd ❑ 5th ❑ 3`d ❑ Other: We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: # Of Descriptions: Includes: # Of Descriptions: Copies: Copies: ❑ Structural Plans ® 1 Revised Struct. Plans ❑ Structural Calculations ® 1 Revised Struct. Calcs ❑ Truss Calcs ❑ Revised Truss w/Ltr. ❑ Soils Report ❑ Revised Soils Report ® 1 Structural P/C Comments ❑ Approved Structural Plans ® 1 Redlined Structural Plans ❑ Approved Structural Calcs ® 1 Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs ❑ Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments: Structural content is approvable; Please add the notes as marked on plan sheet 3 to the 2nd set of plans. If you have any questions please call. ME Structural Plan Review Time =1.0 Hrs. A UG 3 2012 This Material Sent for: ❑ Your Files ® Per Your Request By ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of: Other: ❑ .By: John W. Thompson Rancho Mirage Office: ® (760) 834-8860 Other: ❑ P.O. BOX 1504 LA Q.UINTA' CALIFORNIA 92247-1504 .78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT PROPERTY OVIER' S PACKAGE (760) 777-7012 FAX (760) 777-7011 Disclosures & Forms for Owner-Buff4ers Applytn for Construction Pel*Wts 1XIMM—NT1 No WE*. Dear Property Owner An. application for a budding Mn* has bora sub mitted irE your name listing youEself as the budder of the property imPmVemeaw specified at �7 ViEo are priding you Ith an Owner -Builder Ackll vtat men(4ad InfiwmabeA verifisem Yoram to maim You avm of your and ate risk you may incur by tfds a u�i 4�-�uiklex. We WW Eos Issue b't-ice. itE your two as .then ding -permit until yw1sve read, hM yow. uadegsbeadin of ea*'praldon, signed, and returned. this form to us at our.oflidal address Indicated, An agent of the owner cannot exceube dais -notice unless you, the property owner, obtain the prior approval of the permiCting authority - T Er 1 L �1L��iasl. 6+! 1 i'� 6 w_ #►� ,; ' ! ` �� �y<s y� �� \'ia_ls:i;_ �a roiJ:fY4110 M, 1. I understand a ficquent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder~' building permit that erroaeousiy implies that the property owner is providing his or her own labor and materia! pelsonaft. I, as an Owner -Builder, may be held liable and subject to serious financial nsk for any injuries sustained by an unlicen ed poser and his or her employees while woriang on my property My homeowner's insturanoe may not provide covane, br those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my inssuancx coverage for injuries to wodwn on my property. 0-2. I understand building permits are not required to be signed by property owners unless they are respoas0h for th construction acrd are not hiring a licensed Contractor to assume this r+espoustulay_ 3. I understand as as'X)Wuw-Biuldee` E 81n the - - mysel€from potential financial risk b °n��b party of record on the permit. T uneferstand amt I may prote y hung a licensed Contractor and having the Qecmit filed in his ©t _her name instead of o own. - - - understand Contractors are required by law to be licensed and bonded in California and to list their license mrmbe rs permits and contracts. 5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total vi of my construction is at least five hundred dollars (5500)., including labor and materials, I may be considered an `e mplo: under state and federal law. 6. I understand if I'am considered an "emptoyCc" under state and Waal taw, I must register with the state.and fei government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to uaemploy compensation for each "employee." I also understand my failure to abide by these laws may subject me to se nous fina risk 7. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family resid structures cannot legally build. them with the intent to offer them for sale, unless all work is performed by lie' subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is pert under contract with a licensed general building Contractor. 8. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial • or personal. *ries sustaineda by :any subsequent � owner(s) that result from any latent construction defects in the fi worlamansiiip. of mated4k ILH-4. I understand I may obtain more information regarding my 'obligations as an•"employer", frota the tdernd ane Service, the United States Small Business Administration, the California Department of Benefit Payaterifb, and tha California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CS) at l- 800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. It( 10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the ply legally and fiMWA&lly responsible for proposed construction activity at the following address: agree that, as the party legally and ftnaucially responsible for this proposed ogmtrtrction activity, l will abide by all applicable laws and requirements that govern Owner -Builders as well as employers. 12.1 agree to notify the issuer of this form immediately of aay addittams; delefions, or GUIDWS twtcny 9f the infer I have provided on this form.. Licensed contractors are regulated by taws designed to protect the public. If You Contract with someone who does not have a Imense, rho Contracters' Sate License Dead may be ttnaMe W sssWt you with any fiamaid loss you may sustain as a result of a complaint. Your only remedy against unliceesed Contractors may bio ittv" VOILL It is also itnportant far you to undwaad dw if air unhooaaed Contactor or ewpfoyw of do individwd of fkm is i> d while vmdkmg on Your property, H"y, you may be hdH"ftdYatVm If you obtain a permit as Owner -Bonder atm wish to trim Cmufttom you will be iespousibfe for ve itf�irQ Wk6w or not those Coau, r Wray are prey Iloensed and rte ttt►t a of tM wd=s' motion it cc coverago. Before a btdlding permit can be inn* dds farm must be compteted and signed by tate property owner and returned to the agency responsible for tualft ftp- Notre A cam of dw rvrery owrw's dWVCF'V i fam notak"b24 a oder verification aceta so & Fs r+e+ w'md to be prweated when dke pomit is i 2"A Aa dw Irro en owner's signature signature of property owner �� uzcf A Date: _iLf/ /Z Note: 77efollowing Audiorization Form is i+egwred to be completed by the property owner oarly when m. an agent of the property owner to apply for a construction permit for the Owner -Builder. AMUTHORU ATION OF AGENT TO ACT ON PROPERTY El WKMS D Excluding.the Notice to Property Owner, the execlutien of which I understand is my pesraomal tesponsibilitY, I tm*y WA6Dri rho following perma(s) to act as my egent(s) to apply for, sign, and file tate doaimems nccessW to obtain an Owner-Buihie Permit for my plojeet. Scope of Construction Project (or Description of Work): Project Location or Address: Name of �kuthoriaed Agent: Addrew of Authorized Agent: Tel No I declare under penalty of perjurythat I am the property owner for the address listed above and I personally filled out the information and certify its accuracy. Note: A copy of the owner's driver's he a sse, form notarizau0n. or other verocatim acceptable to the agency is required to be presented when the permit is issued to verify the property owner's sigrurture.. Property Owner's Signature: Date: 8. I understand as an Owner -Builder if I sell the property for which this pemut is issued, I may be bold liable for any financial • or personal. b juries wed by any subsequent , owner(s) that result from any latent construction defects in, the workmansWup.ormatmi4k . _H9. I undMUnd I may obtain more information regarding my obligations as an "employee" from the IaUwast R vvmuo Service;, the United States Small Business Administration, the California Department of Be atfit Paymc"s. and the C U'Muis Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CS; at I- 800-321 -CSLJ3 -800-321-CSLB (27 52) or www.cstb.ca.gov for more information about licensed contractors. W ( 10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the pay legally and financially resp=Mt for proposed construction activity at the following ac,ress: 11. I agree that, as the party legally and fpuaacinlly responsible for this proposed construction activity, I velli abide by all applicable laws and requirearents that govern Oviaer-Builders as well as employers. 12.1 agree to notify the issuer of oris form immediately of any additions, dem, or obaem to any of dtoWMM8fiWI have provided on this forty.. Licensed contractors are regulated by laws designed to protect the public. If you wmrict with someone who docs not have a tiro, aro Conuadors' State License Board mty be umbte to aseat you with MY loss YOU may atrstain as a result of a complaint Your only remedy against unlicensed Coafractors may bo irty" W49L t is also haportma for you to mad dw if an udhoomed COUUCW or CaVtoyft of %d W&vwd or &m is irjurad whila waea ng on your Pmperty. you any be Edd Ii" ft damagm If you obtain, a permit as Owaec-INdder and with to Ise Cocoa tom you will be mWomMo. far vuifft i&Aw or not arose Cam=w s are prei e* licensed sad tae MM of char aro&me eompeawreion insa mroe Coverage. Before a buddlag per dt c= be lasered, this form mast be compkted and sighed by the; property QwRt r sad rtmutd t tate nency respoWAbie for kvdft ft f W=IL Now A can of *c prvpwV owma's Mrwyx IMM fah e other rtr#eotloA a®oeppe6la isdie qpnq a. e, M%Vd to be Froseaw wit= doe Pawk is lasered to VW* etre p+epes owner's skmawre. . Note: The foUowing Au&orizadon Form is required to be completed by the property owner otxly when darmata an agent of the property owner to apply for a construction permit for the Owner -Builder. AUFE U Z,ATEQN 4F AGMTTO ACT ON MOPER'TY U%WWS WATAX Excluding.the Notice to Property Owner, the e"qutioa of which I understand is my porabnal pe9p0asr-brLty, I Raney author the followi% paaort(s) to act as my z r) to apply for, sign, and file fhe domtmenta nootawy to obtain an OwW-Bund Permit for my project Scope of Consftwtiou Project (or Descripf on of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out tt information and Certify its accuracy. Note: A copy of the owner's driver's hcense, form notarization, or other ta*" acceptable to the agency is required to be presivued when the permit is issued to verify the property owner's satnature Property Owner's Signature: Date: BUILDING ENERGY ANALYSIS REPORT Y • r PROJECT: Residence -57-595 South Valley Lane La Quinta, CA Project Designer: r Report Prepared by: Joan D. Hacker Insu-form, Inc. 77=810 Las Nlontanas Road, Suite 201 Palm Desert, Ca 92211 760-3,45-1352 8WUV .!2• CITY CT LA QUINTA BUILDING $ SAFETY DEPT. Job Number: APPROVE® FOR CONSTRUCTION D DATE 404tBY Date: APR 10 ZGQ 4/412012 By The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysaft.com. . Energyft 5. 1 by EnergySoft, User Number 2655 RunCode:2012-04-04T17:59:42 ID: TABLE OF CONTENTS Cover Page 1 Table of.Contents 2 Form CF -1R Certificate of Compliance 3,, Form MF=1 R Mandatory Measures Summary 10' ' -HVAC System Heating and Cooling Loads Summary 13 r 1 EnergyPro 5.1 by Energysoft Job Number. ID: User Number. 2655' PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Residence Building Type ® Single Family O Addition Alone ❑ Multi Family ® Existing+ Addition/Afteration Date 4/4/2012 Project Address 57-595 South Valley Lane La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area -F 2,322 Addition 521 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes El No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special CavityFeatures see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 1,801 Perim = 125' Existing Wall Wood Framed R-13 642 Existing Roof Wood Framed Attic R-22 3,982 Existing Roof Wood Framed Attic R-22 521 New Wall Wood Framed R-13 356 New Slab Unheated Slab -on -Grade None 521 Perim = 26' New FENESTRATION Orientation Area U- Exterior Factor SHGC Overhang Sidefins Shades Status Front (S) 272.0 0.710 0.73 2.0 none Bug Screen Existing Left (IM 64.0 0.710 0.73 2.0 none Bug Screen Existing Left (M 48.0 0.710 0.73 2.0 none Bug Screen Existing Left (IM 48.0 0.710 0.73 2.0 none Bug Screen Existing Left (►M 48.0 0.710 0.73 2.0 none Bug Screen Existing Left (tM 48.0 0.710 0.73 2.0 none Bug Screen Existing Rear (N) 100.0 0.710 0.73 2.0 none Bug Screen Existing Rear (N) 128.0 0.710 0.73 2.0 none Bug Screen Existing Right (E) 64.0 0.710 0.73 2.0 none Bug Screen Existing Right (E) 16.0 0.710 0.73 2.0 none Bug Screen Existing Right (E) 12.0 0.710 0.73 2.0 none Bug Screen Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnefgySoft User Number. 2655 RunCode: 2012-04-04T17:59:42 ID: Page 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Afteration Date 4/4/2012 Project Address 57-595 South Valley Lane La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,322 Addition 521 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (S) 8:0 0.710 0.73 2.0 none Bug Screen New Rear (N) 8.0 0.710 0.73 2.0 none Bug Screen New Right (E) 64.0 0.710 0.73 2.0 none Bug Screen New Right (E) 64.0 0.710 0.73 2.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2012-04-04T17.59.42 ID: Page 4:of-131 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF-1 R Project Name Residence Building Type ® Single Family ❑ Addition Alone I ❑ Multi Family ® Existing+ Addition/Alteration Date 4/4/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. Ene Pro 5.16 Ene Soft • User Number. 2655 RunCode: 2012-04-04T17:59:42 ID: Page 5 of 13 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family O Addition Alone Date Residence ❑ Multi Family m Existing+ Addition/Alteration 4/4/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kgtu/ftZ Space Heating 23.51 22.38 1.13 Space Cooling 191.15 191.03 0.13 Fans 42.65 42.51 0.14 Domestic Hot Water 16.97 16.97 0.00 Pumps 0.00 0.00 0.00 Totals 274.28 272.88 1.40 Percent Better Than Standard: 0.5% ` BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg . Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 500 280 Fuel Available at Site: Natural Gas (M 350 256 Raised Floor Area: o (N) 730 236 Slab on Grade Area: 2.322 (E) 410 220 Average Ceiling Height: 6.0 Roof 4,503 0 Fenestration Average U -Factor: 0.71 TOTAL: 992 Average SHGC: 0.73 Fenestration/CFA Ratio: 42.7 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. , /4/101 Address 77-810 Las Montanas Road, Suite 201 Name Joan D. Hacker City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Sin Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company /• Address Name City/State/Zip . Phone Signed/' ign License # Date EnemvPro 5.1 by EnemySoft User Number. 2655 RunCode: 2012-04-04717:59:42 ID.-' Page 6 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Residence Building Type ® Single Family O Addition Alone 0 Multi Family ® Existing+ Addition/Alteration Date 1 4/4/2012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavitv Exterior Frame Interior Frame Azm Joint Appendix Tilt I Status 4 Location/Comments Slab 1,801 0.730 None 0 180 Existin 4.4.7-A1 Existing Living Wall 78 0.102 R-13 180 90 1 Existing 4.3.1-A3 Existing Living Wall 94 0.102 R-13 270 90 Existing 4.3.1 A3 Existing Living Wall 352 0.102 R-13 0 90 Existing 4.3.1-A3 Existing Living Wall 118 0.102 R-13 90 90 Existing 4.3.1-A3 Existing Living Roof 3,982 0.043 R-22 180 0 Existing 4.2.1-A6 Existing Living Wall 300 0.102 R-13 90 90 Removec 4.3.1-A3 Existing Living Roof 521 0.043 R-22 180 0 New 4.2.1-A6 Addition Wall 142 0.102 R-13 180 90 New 4.3.1 A3 Addition Slab 1 521 0.730 None 0 180 New 4.4.7-A1 Addition Wall 142 0.102 R-13 0 90 New 4.3. i -A3 Addition Wall 72 0.102 R-13 90 90 New 4.3.1 A3 Addition FENESTRATION SURFACE DETAILS ID T e I Area U -Factor SHGC Azm Status Glazing T e Location/Comments 1 Window 1 120.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 2 Window 80.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 3 Window 48.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 4 Window 24.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 5 Window 64.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 6 Window 48.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 7 Window 48.0 0.710 Default 0.73 Default 270 Existin Double Metal Clear Existing Living 8 Window 48.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 9 Window 48.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 10 Window 100.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 11 Window 128.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 12 Window 64.0 0.710 Default 0.73 Default 901 Removed Double Metal Clear Existing Living 13 Window 64.0 0.710 Default 0.73 Default 90 Removed Double Metal Clear Existing Living 14 Window 64.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 15 JMndow 16.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 16Window 12.0 0.710 Default0.73 1 Default 90 Existing Double Metal Clear I Existing Living (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len H t LExt REM Dist Len H Right Fin Dist Len H t 1 Bug Screen 0.76 10.01 12.0 2.01 0.1 2.0 2.0 2 Bug Screen 0.76 8.0 10.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 4 IBug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.01 2.0 7 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.01 2.0 8 Bug Screen 0.761 8.0 6.0 2.01 0.1 2.0 2.0 9 Bug Screen 0.76 8.0 6.0 2.01 0.1 2.0 2.0 10 Bug Screen 0.76 10.0 10.0 2.01 0.1 2.0 2.0 11 Bug Screen 0.76 8.0 16.0 2.01 0.1 2.0 2.0 12 Bug Screen 0.76 8.0 8.0 zol 0.1 2.0 2.0 13 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 8.01 8.0 2.0 0.1 2.0 2.0 15 Bu Screen 0.76 2.0 8.0 2.0 0.1 2.0 2.0 16 Bu Screen 0.76 2.0 6.0 2.0 0.1 2.0 2.0 EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2012-04-04T17:59:42 ID: Page 7 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF-1 R Project Name Residence Building Type O Single Family ❑ Addition Alone I O Multi Family 0 Existing+ Addition/Alteration Date 141412012 OPAQUE SURFACE DETAILS Surface U- Insulation. Joint Appendix Type Area Factor Cavitv Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI-Factor' SHGCz Azm Status Glazing Type Location/Comments 17 Window 8.0 0.710 Default 0.73 Default 180 New Double Metal Clear Addition 18 Window 8.0 0.710 Default 0.73 Default 0 New Double Metal Clear Addition 19 Window 64.0 0.710 Default 0.73 Default 90 New Double Metal Clear Addition 20 Window 64.0 0.710 Default 0.73 Default 90 New Double Metal Clear Addition (1) U-Factor Type: 116-A = Default Table from Standards, NFRC =Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade T H e SHGC t Wd Ove hang Left Fin Ri ht Fin Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 2.0 4.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 2.0 4.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 20 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 EnerqyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2012-04.04T17:59:42 ID: Page 8 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 4/4/2012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built Living Zone Existing Living 1,801 14,408 1979 Addition 521 4,168 Totals 5211 1,8011 0 0 HVAC SYSTEMS System Name CIty. Heating Type Min. Elf. Cooling Type Min. Elf. Thermostat Type Status Living Zone 2 1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.53 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS I HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length lf c _ o m v ¢ — System Name Pipe . Length Pipe Diameter Insul. Thick. Oty. HP Plenum Outside Buried 0. ❑ ❑ EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2012-04-04T17:59:42 ID. Pa e 9 of 13 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Residence Date 4/4/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelop! Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturers installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall or equivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. §150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CFA R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous buming pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pumpisolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatino sections of hot water pipes are insulated per Standards Table 150-6. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(0)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water-hea ting systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoff User Number 2655 RunCode: 2012-04-04T17:59:42 ID: Page 10 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Residence 4/4/2012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)l : Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150(m)10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by § 150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2012-04-04T17:59:42 ID: Page 11 of i3 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Residence 4/4/2012 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131 134 and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoff User Number. 2655 RunCode: 2012-04-04T17:59:42 ID. Page 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Residence Date 4/4/2012 System Name Living Zone Floor Area 2,322 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING PEAK CFM Sensible Total Room Loads 3,069 80,127 Return Vented Lighting o Return Air Ducts 6,794 Return Fan 01 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 6,794 TOTAL SYSTEM LOAD 1 93,716 COIL HTG. Latent CFM 3,241 1,087 0 0 3,241 PEAK Heating System Senslble Output per System 70,000 55,246 Total Output Btuh 140,000 Output Btuh/s ft 60.3 3,925 Cooling System 0 Output per System 47,0001 0 Total Output Btuh 94,000 0 Total Output ons 7.8 3,925 Total Output Btuh/s ft 40.5 Total Output s ft/Ton 296.4 1 63,097 Air System CFM per System 1,300 HVAC EQUIPMENT SELECTION Airflow cfm 2,600 Existing HVAC 78,946 0 140,000 Airflow cfm/s ft 1.12 Airflow(cfm/Ton)-331.9 Outside Air°i, 0.0% Total Adjusted System Output 1 78,946 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 0 Aug 3 PM 1 140,000 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF 0' : Outside Air 0 cfm Supply Fan 2,600 cfm 69 OF 69 OF 119 °F _- Heating Coil i 4 118 °F ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112!78°F 80!61 OF 80/61 OF 51 /50°F Outside Air — 0 cfm Supply Fan Cooling Coil 2,600 cfm 36.7% 80 / 61 OF rl 53 /51 OF ROOM k 78 / 61 OF EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2012-04-04T17:59:42 ID: Page 13 of 13