Loading...
13844 (SFD)P.O. BOX 1504 Building 44_580 Verbena Drive78-105 CALLE ESTADO AririrPcc LA QUINTA, CALIFORNIA 92253 Owner Pager Snellenberger & Associates Mailing Address 55-595 Pebble Beach ' City Zip Tel. La Quinta, CA 92253 1(619)777-7767 Contractor Sam,e Address City lZip State Ljc.Cit B 488234 I Licy# 1858 & Classif. Arch., Engr., Designer Carlos Elias -- Engineer A3 t3z5 Charlesworth Dr. T(6l9) 328--7271 City, Zip State Cathedral Cit. 92234 Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm h�t-1 arts licensed under provisions of Chapter 9 (commancing,,�ith Sectipn 7000) of Divisior>�3`o2 helBusiness�and;Professions Code, and my license is,in4fuU;force and. OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its Issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) O I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COM PENSATIO N INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT., If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives .of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip No. 18844 BUILDING: TYPE CONST. VN OCC. GRP. R3 A.P. Number 604"252-410 Legal Description Lot. 30 `bract 24208 Project Description SFV Plan 7 Cactus Flower Sq. Ft. 1867 No. No. Dw. Size Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation $114t706.00 PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. 51dU.26 Const. 692. Uu Mech. 55. SU Electrical 142.45 Plumbing 144.00 S.M.I. 11.4 Grading 20 * at) Driveway Enc. .00 Infrastructure 1 1530 .8 9 s in - n.Llc ?.Laces TOTAL 4,1b3.j REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback rom Rear Prop. Line Si Setback from Center Line Side Set ack from Property Line FINAL DATE INSPECTOR Issued by: Date dp fmlitt r4 Validated by: � 19Q,4 �. Validation: I� CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SQ. FT. ® $ UNITS ROUGH PLUMB. BONDING 'i HEATING (ROUGH) YARD SPKLR SYSTEM 2ND FL. SO. FT. ® SEWER OR SE N ROUGH WIRING DUCT WORK MOBILEHOME SVC. BAR SINK POR. SQ. FT. ® METER LOOP HEATING (FINAL) GAR. SQ. FT. ® POWER OUTLET .-- . _ . .... ROOF DRAINS - a TEMP. POLE DRAINAGE PIPING CAR P. SQ. FT. ® WATER HEATEA SERVICE WALL SQ. FT. p DRINKING FOUNTAIN. WATER SYSTEM URINAL SQ. FT. ® LUMBER GR. FINAL INSP. L ESTIMATED CONSTRUCTION VALUATION $ FINAL INSP. WATER PIPING NOTE: Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER FIRE ZONE ROOFING GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED FIREPLACE LAUNDRYTRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE,TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SQ. FT. ® c BATH TUB SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 11/4 c SEWAGE DISPOSAL SQ.FT.GAR ® 3/ac HOUSE SEWER FINAL INSPECTION GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK 011 GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE1111_z� ROUGH PLUMB. BONDING 'i HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SE N ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATEA SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ -Plus-X$-=$ LUMBER GR. FINAL INSP. L FRAMING t- FINAL INSP. ROOFING Q r REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LAC 0L,1 MESH INSULATIONISOUND to r3 FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL I TITLE 24 REPORT I G Title 24 Report for: ARTURO & OLIVIA GONZALEZ 44580 VERDENA DR. LA QUINTA, CA 92253 Project Designer: ENRIQUE RODRIGUEZ . 2500 N. PALM CANYON A-5 PALM SPRINGS, CA 92264 (760),321.-4941.- Report 760),321.-4941 Report Prepared By: HIGH TECH DESIGN Al Simeone Design 737 1/2 Neptune Ave. Apt. C Encinitas, CA 92024 (760) 634-1272 Job Number: 00001 Date: 7/19/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: 00001 User Number: 5940 TABLE OF CONTENTS 'Cover Page 1 Table of Contents 2. - Form CF -1 R Certificate of Compliance 3, Form MF -1 R Mandatory Measures Checklist 5 Form C -2R Computer Method Summary 7 HVAC System Heating and Cooling Loads Summary10 Room Load Summary 11 Certificate of Compliance: Residential • i (Part 1 -of 2) CF -1 R ARTURO & OLIVIA GONZALEZ " 7/19/2005 Project Title Date u 44580 VERDENA DR. LA'QUINTA Covered Slab w/R-0.0 Perimeter Insulation Project Address Building Permit # Al Simeone Design (760) 634-1272 Plan Check'/ Date Documentation Author Telephone Wood Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only " GENERAL INFORMATION ❑ x❑ Total Conditioned Floor Area: 404 f? Average Ceiling Height: - 10.0 ft Total Conditioned Slab Area: 404 f? 0.65 Building Type: 1-1 (check one or more) - Left X❑ Single Family Detached ❑ Addition 0.60 ❑ Single Family Attached ❑ Existing Building- Bug Screen ❑ Multi -Family ❑ Existing Plus Addition • '❑ x❑• Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 0.65 Number of Stories: -1 ❑ Raised Floor BUILDING SHELL INSULATION Component Type Frame Type Const. Assembly U -Value - Location/Comments _ (attic, garage, typical, etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation R-13 Wall (W.13.2x4.16) Wood 0.088 Exterior Wall R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof w FENESTRATION ShadinDevices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front 40.0 0.60 0.53 Bug Screen X❑ ❑ ❑ x❑ Front 4.0 0.60 0.65 Bug Screenx❑ 1-1 ❑ X❑ Left 4.0 0.60 0.65 Bug Screen x❑ ❑ '❑ x❑• Right 17.5 0.60 0.65 Bug Screen x❑ ❑ ❑ X❑ ❑ ❑ ❑ ❑ ' ❑ ❑ ❑ ❑. ❑• ❑ ❑ ❑ ❑. ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ R El ❑ ❑ Run Initiation Time: 07/19105 11:53:33 Run Code: 112179 213 Ener Pro 3.1 By Ener Soft - User Number: 5940 Job Number: 00001 Pa e:3 of 11 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R ARTURO & OLIVIA GONZALEZ 7/19/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat _ Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Packaged Heat Pump_ 3.90 COP Ducts in Attic 42 Setback HVAC System Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Hydronic Heat Pump 11.0 EER Ducts in Attic 42 Setback HVAC System WATER HEATING SYSTEMS Rated 1 Tank Energy Fact' 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System'Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O. SMITH FPS -40-224 Small Gas Pipe Insulation 1 42,000 40 0.62 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS cUmrLIAIVct J i A i tMtN I This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. ; Designer or Owner (per Business & Professions Code) Name: Title/Firm: ENRIQUE RODRIGUEZ Address: 2500 N. PALM CANYON A-5 • • PAL' SPRINGS. CA 92264 Telephone: 760 21 4 Lic. #: (signature) ,i (date). Enforcement Agency Name: Title/Firm: Address: Telephone: Documentation Author Name: HIGH TECH DESIGN Title/Firm: Al Simeone*Design Address: 737 1/2 Neptune Ave. Apt C Encinitas CA 92024 Telephone: 760 634-1272 ITCi Gv �s (signature) (date) IEnergyPro 3.1 By EnergySoft . User Number: 5940 Job Number: 00001 Paae:4 of 11 1 Mandatory'Measures Checklist: 'Residential'' (Page '1 of, 2) • MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (7 may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures "§150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. 11 50(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ❑'§150(d): Minimum R-13 raised floor insulation in framed Floors or equivalent. §150(1)' Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. ❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. S 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. . §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ c ❑§150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards: ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: t a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures , §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. r A § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. , § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ §1500): Pipe and Tank Insulation e 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) - 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. ' 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. - EnergyPro 3.1 By EnergySoft User Number: 5940 Job Number: 00001 Page:S of 11 r F Mandatory Measures Checklist: Residential (Page -2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. 3.1 By EnergySoft } User Number: 5940 Job Number: 00001 Page:6 of 11 DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. ' DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) a11150(m): Ducts and Fans r 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, ' 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in n s, conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system ' that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings r , greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive duct tapes unless such tape is used in combination with mastic and • ' drawbands.. �- 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other. than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. , 3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive 4, duct tapes unless such a tape is used in combination with mastic and drawbands. t' i 4. Exhaust fan systems have back draft or automatic dampers. . k 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually ' operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam f insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. a§ 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 1 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas.:.. 1 a. At least 36" of pipe between filter and heater for future solar heating., b. Cover for outdoor pools or outdoor spas. r 3. Pool system has directional inlets and a circulation pump time switch. , d IX -1 §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no r continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) - i �t §118 (f)* Cool Roof material meet specified criteria Lighting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for w general.lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. FX] §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement ' allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft } User Number: 5940 Job Number: 00001 Page:6 of 11 Computer Method Summary (Part 1 of 3) C -2R ARTURO & OLIVIA GONZALEZ 7/19/2005 Project Title Date 44580 VERDENA DR. LA QUINTA Project Address Building Permit # Al Simeone Design (U 634-1272 Documentation Author Telephone Plan ChecklDate Computer Performance 15 Field Check/Date ' Compliance Method (Package or Computer) Cimate Zone Source Energy Standard Use (kBtu/sf-yr) Design Space Heating 5.77 Facing North Margin 90 Facing East Margin i Facing South Margin 1st-Fj r Facing West Margin 4.92 0.85 4.60 1.17 4.57 1.19 4.61 1:16 Space Cooling 81.68 70.56 11.12 Wall_ _213 69.36 12.32 _9.0_ 70.17 11.51 ❑ 69.70 11.98 Domestic Hot Water 45.37 34.50 10.87 0,088 270_ 34.50 10.87 34.50 10.87 _FL1.3_WaIL(W 13.2x4 16) R38Boot(R38.2x14.16) 34.50 10.87 109.98 22.83 108.46 24.35 109.25 23.57 108.81 24.01 Totals 132.82 1SLFJO.or This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations. Total Conditioned Floor Area: 404 ft 2 Building Type: Single Fam Detached Floor Construction Type: ❑ Raised Floor [X Slab Floor' Building Front Orientation: All Four Orientations Total Fenestration Area: 16.2% Number of Dwelling Units: 1.00 Total Conditioned Volume: 41040 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 404 ft2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC -System 404 ----4,040 -._OD_ Coaditiaaed- -Setback- -2 n OPAQUE SURFACES Tvae Area U -Val. Solar Act. Gains Azm. Tilt Y / N Form 3 Reference ,.. Location / Comments Wall_ _____103 .0 088 0_ 90 � i _RA3_VVa. L(VIC_t3.2x4._1_6.) 1st-Fj r Wali- -2.04 _0_OB.8. 94 9-0_ ❑ P_-J.3_Wa1L(W_ _1-3.2x41-6) 1st_F_lo6r Wall_ _213 _0_0.8.8_ 1-80 _9.0_ ❑ _RJ.3_Wa1L4_W1.32x4 1.6) JstF_loor Wall_ _203 0,088 270_ 80 ❑ ❑❑ _FL1.3_WaIL(W 13.2x4 16) R38Boot(R38.2x14.16) r 1stEloor _Roof_ X34 -0-008- 0 0 1SLFJO.or go �o ❑❑ ❑o g❑ ❑❑ 00 ❑❑ oa ❑❑ 00 El 1-1 Run Initiation Time: 07119/05 11:53:33 Run Code: 1121799213 3.1 By EnergySoft User Number: 5940 00001 Page:7 of 11 INTERIOR AND EXTERIOR SHADING Overhang Window # Exterior Shade Type SHGC Computer Method Summary 1 Bug Screen (Part 2 of 3) C -2R ARTURO & OLIVIA GONZALEZ 2 Bug Screen 0.76 1.0 2.0 7/19/2005 Project Title 0.76 1.0 2.0 4 Date 0.76 FENESTRATION SURFACES 5 Buy Screen 0.76 1.0 2.0 6 . Bug Screen U- 3.5 --5-0 Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments •_L Window_Eront_(N.orth) _40_0 _0_6.0.0_ _0._5.3_ 0_ _90 Double-NonMtLLftted-.efault_ 1.sLEtoor 2 Window Front North. 2.0 0.600 0.65 0 90 Double NonMtl Clear Default 1st Floor 3 Window FrontNorth . 2.0 0.600 0.65 0 90 Double NonMtl Clear Default 1st Floor 4 Window Left East 2.0 0.600 0.65 90 90 Double NonMtl Clear Default 1st Floor 5 Window Left East 2.0 0.600 . 0.65 90 90 Double NonMtl Clear Default 1st Floor 6 Window Right West 17.5 _ 3 0.600 0.65 270 90 Double NonMtl Clear Default 1st Floor INTERIOR AND EXTERIOR SHADING Overhang Window # Exterior Shade Type SHGC Hgt. Wd. 1 Bug Screen 0.76 6.0 4.7 2 Bug Screen 0.76 1.0 2.0 3 Bug Screen 0.76 1.0 2.0 4 Bug Screen 0.76 1.0 2.0 5 Buy Screen 0.76 1.0 2.0 6 . Bug Screen 0.76 3.5 --5-0 2 0 i R tui n Initiation Time: 071, i EnerovPro 3.1 By EnerovSoft User Number: 5940 3 Run cc; de: 1121799213 Job Number: 00001 Page:8 of 11 Overhang Left Fi Len. Hgt. LEA . RExt. Dist. Len. 10.0 • 0.1 10.0 10.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 0.1 2.0 2.0 2.0 0. 2.0 2 0 3 Run cc; de: 1121799213 Job Number: 00001 Page:8 of 11 Computer Method Summary. (Part 3 of 3) C -2R ARTURO &OLIVIA GONZALEZ 7/19/2005 Project Title Date THERMAL MASS FOR HIGH MASS,DESIGN ` Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation ' Type Length Factor R -Val. Depth Location / Comments " flab Pe —ri meter 9a 0—M �.0 9 1st Flo, r HVAC SYSTEMS Heating Equipment Minimum Distribution Type ' Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value _ Type Comments ea9kaged Fi ttPumo 3_ 0 P Ducts in Atts 4.2 `' Setbjck— HVAC�y_atem Hydronic Piping Pipe Pipe Insula x System Name Length Diameter Thick. i Cooling Equipment Minimum Duct t ' Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments + H r n'c Heat Pump 11. EE Duct_ i A is 4.2 $mit k HVAC Svstem WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) • (gal) Efficiency Loss (%) Ext. A.O. SMITH FPS -40-224 Small Gas Pipe Insulation 1 42,000 40 902 n/a n/a 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. , REMARKS Run Initiation Time: 07/19/05 11:53:33 "Run Code: • 1121799213 EnergyPro 3.1 By EnergySoft User Number: 5940 Job Number: 00001 Page:9 of 11 . s HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE ARTURO & OLIVIA GONZALEZ 7/19/2005 SYSTEM NAME FLOOR AREA ' HVAC System 404 ' Number•of Systems 1 Heating System - Output per System 42,500 Total Output (Btuh) 42,500 Output (Btuh/sgft) 105.2 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 86.6 Total Output (sgft/Ton) 138.5 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 2.97 Airflow (cfmfTon) 411.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 427 9,095 1,034 432 12,745 EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 0 26.0 of 69.5 of 69.5 of 98.2 of 455 637 0 0 0 0 0 0 0 0 - 0 455 637 TOTAL SYSTEM LOAD 1 '10,004 1,0341 14,0191 HVAC EQUIPMENT SELECTION CARRIER 50HQA036 26,466 9,297 36,659 Total Adjusted System Outputz6,a66 9,297 36,659 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug -2 pm . Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.5 of 69.5 of 98.2 of Supply Air Ducts Outside Air O 0 cfm Supply Fan . , Heating Coil 97.7 of 1200 cfm I ROOMS 70.0 of 69.5 of Return Air Ducts ' DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 of 78.4 / 64.19F 78.4 / 64.1 of 57.6 / 56.5 of O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 58.0 / 56.6 of 1200 cfm ROOMS 46.7% R.H. 78.4/64.10F 78.0/64.0 OF Return Air Ducts I r EnergyPro 3.1 By EnergySoft User Number: 5940 Job Number. 00001 Page:10 of 11 ROOM LOAD SUMMARY PROJECT NAME ARTURO & OLIVIA GONZALEZ DATE 7/19/2005 SYSTEM NAME HVAC System FLOOR AREA 404 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE 1st Floor 1st Floor 1 427 9,095 1,034 427 9,095 1,034 432 12,745 PAGE TOTAL 127 9,095 1,034 432 12,745 TOTAL 1 427 9,095 1,0341 432 12,745 EnergyPro 3.1 By EnergySoft User Number: 5940 Job Number: 00001 Page: 11 of 11