13844 (SFD)P.O. BOX 1504
Building 44_580 Verbena Drive78-105 CALLE ESTADO
AririrPcc LA QUINTA, CALIFORNIA 92253
Owner Pager Snellenberger & Associates
Mailing
Address 55-595 Pebble Beach '
City Zip Tel.
La Quinta, CA 92253 1(619)777-7767
Contractor
Sam,e
Address
City lZip
State Ljc.Cit
B 488234 I Licy# 1858
& Classif.
Arch., Engr.,
Designer Carlos Elias -- Engineer
A3 t3z5 Charlesworth Dr. T(6l9) 328--7271
City, Zip State
Cathedral Cit. 92234 Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm h�t-1 arts licensed under provisions of Chapter 9 (commancing,,�ith Sectipn
7000) of Divisior>�3`o2 helBusiness�and;Professions Code, and my license is,in4fuU;force and.
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its Issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
O I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COM PENSATIO N INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT., If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives .of this city to enter the above-
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
No. 18844
BUILDING: TYPE CONST. VN OCC. GRP. R3
A.P. Number 604"252-410
Legal Description Lot. 30 `bract 24208
Project Description SFV Plan 7
Cactus Flower
Sq. Ft. 1867 No. No. Dw.
Size Stories Units
New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑
Estimated Valuation $114t706.00
PERMIT
AMOUNT
Plan Chk. Dep.
Plan Chk. Bal.
51dU.26
Const.
692. Uu
Mech.
55. SU
Electrical
142.45
Plumbing
144.00
S.M.I.
11.4
Grading
20 * at)
Driveway Enc.
.00
Infrastructure
1 1530 .8 9
s in - n.Llc ?.Laces
TOTAL
4,1b3.j
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback rom Rear Prop. Line
Si Setback from Center Line
Side Set ack from Property Line
FINAL DATE INSPECTOR
Issued by: Date dp fmlitt
r4
Validated by: � 19Q,4
�.
Validation:
I�
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
1ST FL. SQ. FT. ® $
UNITS
ROUGH PLUMB.
BONDING
'i
HEATING (ROUGH)
YARD SPKLR SYSTEM
2ND FL. SO. FT. ®
SEWER OR SE
N ROUGH WIRING
DUCT WORK
MOBILEHOME SVC.
BAR SINK
POR. SQ. FT. ®
METER LOOP
HEATING (FINAL)
GAR. SQ. FT. ®
POWER OUTLET .-- . _ . ....
ROOF DRAINS - a
TEMP. POLE
DRAINAGE PIPING
CAR P. SQ. FT. ®
WATER HEATEA
SERVICE
WALL SQ. FT. p
DRINKING FOUNTAIN.
WATER SYSTEM
URINAL
SQ. FT. ®
LUMBER GR.
FINAL INSP. L
ESTIMATED CONSTRUCTION VALUATION $
FINAL INSP.
WATER PIPING
NOTE: Not to be used as property tax valuation
FLOOR DRAIN
MECHANICAL FEES
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
FIRE ZONE ROOFING
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
FIREPLACE
LAUNDRYTRAY
AIR HANDLING UNIT CFM
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET
COMPRESSOR HP
POLE,TEMIPERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SQ. FT. ® c
BATH TUB
SQ. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SQ. FT. RESID ® 11/4 c
SEWAGE DISPOSAL
SQ.FT.GAR ® 3/ac
HOUSE SEWER
FINAL INSPECTION
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
011 GROUND PLUMBING UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE1111_z�
ROUGH PLUMB.
BONDING
'i
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SE
N ROUGH WIRING
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APPJEOUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATEA
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ -Plus-X$-=$
LUMBER GR.
FINAL INSP. L
FRAMING t-
FINAL INSP.
ROOFING Q
r
REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LAC 0L,1
MESH
INSULATIONISOUND to r3
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURES/INITIALS
GARDEN WALL FINAL
I TITLE 24 REPORT I
G
Title 24 Report for:
ARTURO & OLIVIA GONZALEZ
44580 VERDENA DR.
LA QUINTA, CA 92253
Project Designer:
ENRIQUE RODRIGUEZ .
2500 N. PALM CANYON A-5
PALM SPRINGS, CA 92264
(760),321.-4941.-
Report
760),321.-4941
Report Prepared By:
HIGH TECH DESIGN
Al Simeone Design
737 1/2 Neptune Ave. Apt. C
Encinitas, CA 92024
(760) 634-1272
Job Number:
00001
Date:
7/19/2005
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 897-6400.
EnergyPro 3.1 By EnergySoft Job Number: 00001 User Number: 5940
TABLE OF CONTENTS
'Cover Page 1
Table of Contents 2. -
Form CF -1 R Certificate of Compliance 3,
Form MF -1 R Mandatory Measures Checklist 5
Form C -2R Computer Method Summary 7
HVAC System Heating and Cooling Loads Summary10
Room Load Summary 11
Certificate of Compliance: Residential
• i
(Part 1 -of 2) CF -1 R
ARTURO & OLIVIA GONZALEZ
" 7/19/2005
Project Title
Date u
44580 VERDENA DR. LA'QUINTA
Covered Slab w/R-0.0 Perimeter Insulation
Project Address
Building Permit #
Al Simeone Design (760) 634-1272
Plan Check'/ Date
Documentation Author Telephone
Wood
Computer Performance 15
Field Check / Date
Compliance Method (Package or Computer) Climate Zone
Enforcement Agency Use Only "
GENERAL INFORMATION
❑ x❑
Total Conditioned Floor Area: 404 f? Average Ceiling
Height: - 10.0 ft
Total Conditioned Slab Area: 404 f?
0.65
Building Type:
1-1
(check one or more) -
Left
X❑ Single Family Detached ❑ Addition
0.60
❑ Single Family Attached ❑ Existing Building-
Bug Screen
❑ Multi -Family ❑ Existing Plus Addition •
'❑ x❑•
Front Orientation: All Four Orientations Floor Construction Type: ®
Slab Floor
Number of Dwelling Units: 1.00
0.65
Number of Stories: -1 ❑
Raised Floor
BUILDING SHELL INSULATION
Component
Type
Frame
Type
Const.
Assembly
U -Value
- Location/Comments _
(attic, garage, typical, etc.)
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
R-13 Wall (W.13.2x4.16)
Wood
0.088
Exterior Wall
R-38 Roof (R.38.2x14.16)
Wood
0.028
Exterior Roof w
FENESTRATION
ShadinDevices
Type Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes / No
Yes / No
Front
40.0
0.60
0.53
Bug Screen
X❑ ❑
❑ x❑
Front
4.0
0.60
0.65
Bug Screenx❑
1-1
❑ X❑
Left
4.0
0.60
0.65
Bug Screen
x❑ ❑
'❑ x❑•
Right
17.5
0.60
0.65
Bug Screen
x❑ ❑
❑ X❑
❑ ❑
❑ ❑
' ❑ ❑
❑ ❑.
❑• ❑
❑ ❑
❑. ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
R
El
❑ ❑
Run Initiation Time: 07/19105 11:53:33 Run
Code: 112179 213
Ener Pro 3.1 By Ener
Soft -
User Number: 5940
Job Number: 00001
Pa e:3 of 11
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
ARTURO & OLIVIA GONZALEZ 7/19/2005
Project Title Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat _ Location /
pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments
Packaged Heat Pump_ 3.90 COP Ducts in Attic 42 Setback HVAC System
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments
Hydronic Heat Pump 11.0 EER Ducts in Attic 42 Setback HVAC System
WATER HEATING SYSTEMS
Rated 1
Tank
Energy Fact' 1
External
Water Heater Water Heater Distribution
# in Input
Cap.
or Recovery Standby
Tank Insul.
System'Name Type Type
Syst. Btu/hr
(gal)
Efficiency Loss (%)
R -Value
A.O. SMITH FPS -40-224 Small Gas Pipe Insulation
1 42,000
40
0.62 n/a
n/a
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
cUmrLIAIVct J i A i tMtN I
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater. ;
Designer or Owner (per Business & Professions Code)
Name:
Title/Firm: ENRIQUE RODRIGUEZ
Address: 2500 N. PALM CANYON A-5
• • PAL' SPRINGS. CA 92264
Telephone: 760 21 4
Lic. #:
(signature) ,i (date).
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Documentation Author
Name: HIGH TECH DESIGN
Title/Firm: Al Simeone*Design
Address: 737 1/2 Neptune Ave. Apt C
Encinitas CA 92024
Telephone: 760 634-1272
ITCi Gv �s
(signature) (date)
IEnergyPro 3.1 By EnergySoft . User Number: 5940 Job Number: 00001 Paae:4 of 11 1
Mandatory'Measures Checklist: 'Residential'' (Page '1 of, 2) • MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (7 may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
"§150(a): Minimum R-19 ceiling insulation.
❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value.
11 50(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
not apply to exterior mass walls).
❑'§150(d): Minimum R-13 raised floor insulation in framed Floors or equivalent.
§150(1)' Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
S
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. .
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑ c
❑§150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards:
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have: t
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
,
§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
r
A § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
,
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑ §1500): Pipe and Tank Insulation
e
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater)
-
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems. '
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank. -
EnergyPro 3.1 By EnergySoft User Number: 5940 Job Number: 00001 Page:S of 11
r F
Mandatory Measures Checklist: Residential (Page -2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
3.1 By EnergySoft } User Number: 5940 Job Number: 00001 Page:6 of 11
DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. '
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
a11150(m): Ducts and Fans
r
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, '
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
n
s,
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system '
that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings
r
,
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with Goth back rubber adhesive duct tapes unless such tape is used in combination with mastic and • '
drawbands..
�-
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other.
than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts. ,
3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive
4,
duct tapes unless such a tape is used in combination with mastic and drawbands.
t'
i
4. Exhaust fan systems have back draft or automatic dampers. .
k
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually '
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
f
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
a§ 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot. 1
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.:.. 1
a. At least 36" of pipe between filter and heater for future solar heating.,
b. Cover for outdoor pools or outdoor spas.
r
3. Pool system has directional inlets and a circulation pump time switch. ,
d
IX -1 §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
r
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
- i
�t §118 (f)* Cool Roof material meet specified criteria
Lighting Measures
§150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
w
general.lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
FX] §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
'
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
3.1 By EnergySoft } User Number: 5940 Job Number: 00001 Page:6 of 11
Computer Method Summary (Part 1 of 3) C -2R
ARTURO & OLIVIA GONZALEZ 7/19/2005
Project Title Date
44580 VERDENA DR. LA QUINTA
Project Address Building Permit #
Al Simeone Design (U 634-1272
Documentation Author Telephone Plan ChecklDate
Computer Performance 15 Field Check/Date '
Compliance Method (Package or Computer) Cimate Zone
Source Energy Standard
Use (kBtu/sf-yr) Design
Space Heating 5.77
Facing
North Margin
90
Facing
East Margin
i
Facing
South Margin
1st-Fj r
Facing
West Margin
4.92 0.85
4.60 1.17
4.57 1.19
4.61 1:16
Space Cooling 81.68
70.56 11.12
Wall_ _213
69.36 12.32
_9.0_
70.17 11.51
❑
69.70 11.98
Domestic Hot Water 45.37
34.50 10.87
0,088 270_
34.50 10.87
34.50 10.87
_FL1.3_WaIL(W 13.2x4 16)
R38Boot(R38.2x14.16)
34.50 10.87
109.98 22.83
108.46 24.35
109.25 23.57
108.81 24.01
Totals 132.82
1SLFJO.or
This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations.
Total Conditioned Floor Area: 404 ft 2
Building Type: Single Fam Detached Floor Construction Type: ❑ Raised Floor [X Slab Floor'
Building Front Orientation: All Four Orientations Total Fenestration Area: 16.2%
Number of Dwelling Units: 1.00 Total Conditioned Volume: 41040 ft 3
Number of Stories: 1 Total Conditioned Slab Area: 404 ft2
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
HVAC -System 404 ----4,040 -._OD_ Coaditiaaed- -Setback- -2 n
OPAQUE SURFACES
Tvae Area U -Val.
Solar
Act. Gains
Azm. Tilt Y / N
Form 3 Reference
,..
Location / Comments
Wall_ _____103
.0 088 0_
90
�
i
_RA3_VVa. L(VIC_t3.2x4._1_6.)
1st-Fj r
Wali- -2.04
_0_OB.8. 94
9-0_
❑
P_-J.3_Wa1L(W_ _1-3.2x41-6)
1st_F_lo6r
Wall_ _213
_0_0.8.8_ 1-80
_9.0_
❑
_RJ.3_Wa1L4_W1.32x4 1.6)
JstF_loor
Wall_ _203
0,088 270_
80
❑
❑❑
_FL1.3_WaIL(W 13.2x4 16)
R38Boot(R38.2x14.16)
r
1stEloor
_Roof_ X34
-0-008- 0
0
1SLFJO.or
go
�o
❑❑
❑o
g❑
❑❑
00
❑❑
oa
❑❑
00
El
1-1
Run Initiation Time: 07119/05 11:53:33 Run Code: 1121799213
3.1
By EnergySoft
User Number: 5940 00001
Page:7 of 11
INTERIOR AND EXTERIOR SHADING
Overhang
Window
#
Exterior Shade Type
SHGC
Computer Method Summary
1
Bug Screen
(Part 2 of 3) C -2R
ARTURO & OLIVIA GONZALEZ
2
Bug Screen
0.76
1.0 2.0
7/19/2005
Project Title
0.76
1.0 2.0
4
Date
0.76
FENESTRATION SURFACES
5
Buy Screen
0.76
1.0 2.0
6 .
Bug Screen
U-
3.5 --5-0
Act.
Glazing Type
Location/
# Type Area
Factor
SHGC
Azm.
Tilt
Comments
•_L Window_Eront_(N.orth) _40_0
_0_6.0.0_
_0._5.3_
0_
_90 Double-NonMtLLftted-.efault_
1.sLEtoor
2 Window Front North. 2.0
0.600
0.65
0
90 Double NonMtl Clear Default
1st Floor
3 Window FrontNorth . 2.0
0.600
0.65
0
90 Double NonMtl Clear Default
1st Floor
4 Window Left East 2.0
0.600
0.65
90
90 Double NonMtl Clear Default
1st Floor
5 Window Left East 2.0
0.600
. 0.65
90
90 Double NonMtl Clear Default
1st Floor
6 Window Right West 17.5
_ 3
0.600
0.65
270
90 Double NonMtl Clear Default
1st Floor
INTERIOR AND EXTERIOR SHADING
Overhang
Window
#
Exterior Shade Type
SHGC
Hgt. Wd.
1
Bug Screen
0.76
6.0 4.7
2
Bug Screen
0.76
1.0 2.0
3
Bug Screen
0.76
1.0 2.0
4
Bug Screen
0.76
1.0 2.0
5
Buy Screen
0.76
1.0 2.0
6 .
Bug Screen
0.76
3.5 --5-0
2 0
i
R tui n Initiation Time: 071,
i
EnerovPro 3.1 By EnerovSoft
User
Number: 5940
3 Run cc; de: 1121799213
Job Number: 00001 Page:8 of 11
Overhang
Left Fi
Len.
Hgt.
LEA
. RExt. Dist. Len.
10.0
• 0.1
10.0
10.0
2.0
0.1
2.0
2.0
2.0
0.1
2.0
2.0
2.0
0.1
2.0
2.0
2.0
0.1
2.0
2.0
2.0
0.
2.0
2 0
3 Run cc; de: 1121799213
Job Number: 00001 Page:8 of 11
Computer Method Summary. (Part 3 of 3) C -2R
ARTURO &OLIVIA GONZALEZ 7/19/2005
Project Title Date
THERMAL MASS FOR HIGH MASS,DESIGN
`
Area Thick. Heat Inside
Location
Type
(sf) (in.) Cap. Cond. Form 3 Reference R -Val.
Comments
PERIMETER LOSSES
F2 Insulation
' Type
Length Factor R -Val. Depth Location / Comments
"
flab Pe —ri meter
9a 0—M �.0 9 1st Flo, r
HVAC SYSTEMS
Heating Equipment
Minimum Distribution Type '
Type (furnace, heat
Efficiency and Location Duct Thermostat
Location /
pump, etc.)
(AFUE/HSPF)(ducts/attic, etc.) R -Value _ Type
Comments
ea9kaged Fi ttPumo
3_ 0 P Ducts in Atts 4.2 `' Setbjck— HVAC�y_atem
Hydronic Piping
Pipe Pipe Insula x
System Name
Length Diameter Thick.
i
Cooling Equipment
Minimum Duct
t
' Type (air conditioner,
Efficiency Location Duct Thermostat
Location/
heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type
Comments
+ H r n'c Heat Pump
11. EE Duct_ i A is 4.2 $mit k
HVAC Svstem
WATER HEATING SYSTEMS Ratedl Tank
Energy Fact! 1 Tank Insul.
Water Heater
Water Heater Distribution # in Input Cap.
or Recovery Standby R -Value
System Name
Type Type Syst. (Btu/hr) • (gal)
Efficiency Loss (%) Ext.
A.O. SMITH FPS -40-224
Small Gas Pipe Insulation 1 42,000 40
902 n/a n/a
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby
Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
,
REMARKS
Run Initiation Time: 07/19/05 11:53:33 "Run Code: • 1121799213
EnergyPro 3.1 By EnergySoft User Number: 5940 Job Number: 00001 Page:9 of 11
. s
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME
DATE
ARTURO & OLIVIA GONZALEZ
7/19/2005
SYSTEM NAME
FLOOR AREA
' HVAC System
404 '
Number•of Systems
1
Heating System -
Output per System
42,500
Total Output (Btuh)
42,500
Output (Btuh/sgft)
105.2
Cooling System
Output per System
35,000
Total Output (Btuh)
35,000
Total Output (Tons)
2.9
Total Output (Btuh/sgft)
86.6
Total Output (sgft/Ton)
138.5
Air System
CFM per System
1,200
Airflow (cfm)
1,200
Airflow (cfm/sgft)
2.97
Airflow (cfmfTon)
411.4
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensiblel
Latent
CFM
I Sensible
427
9,095
1,034
432
12,745
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
0
26.0 of 69.5 of 69.5 of 98.2 of
455
637
0
0
0
0
0
0
0
0
-
0
455
637
TOTAL SYSTEM LOAD 1 '10,004 1,0341 14,0191
HVAC EQUIPMENT SELECTION
CARRIER 50HQA036 26,466 9,297 36,659
Total Adjusted System Outputz6,a66 9,297 36,659
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug -2 pm . Jan 12 am
Note: values above given at ARI conditions
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 of 69.5 of 69.5 of 98.2 of
Supply Air Ducts
Outside Air O
0 cfm Supply Fan . , Heating Coil 97.7 of
1200 cfm I ROOMS
70.0 of
69.5 of
Return Air Ducts '
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0 / 77.6 of 78.4 / 64.19F 78.4 / 64.1 of 57.6 / 56.5 of
O Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 58.0 / 56.6 of
1200 cfm
ROOMS
46.7% R.H.
78.4/64.10F 78.0/64.0 OF
Return Air Ducts I
r
EnergyPro 3.1 By EnergySoft User Number: 5940 Job Number. 00001 Page:10 of 11
ROOM LOAD SUMMARY
PROJECT NAME
ARTURO & OLIVIA GONZALEZ
DATE
7/19/2005
SYSTEM NAME
HVAC System
FLOOR AREA
404
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
1st Floor
1st Floor
1
427
9,095
1,034
427
9,095
1,034
432
12,745
PAGE TOTAL 127 9,095 1,034 432 12,745
TOTAL 1 427 9,095 1,0341 432 12,745
EnergyPro 3.1 By EnergySoft User Number: 5940 Job Number: 00001 Page: 11 of 11