04-4591 (SFD)1,/
e
Z
s
5 BUILDING & SAFETY DEPARTMENT
�P O.-BO.)c-LQ, (760).777-7012
Q78-4�5 CALTAMPICO FAX (760) 777-7011
LA QUINTA9i, . I
JUN 16 LIF6RNIA 92253 INSPECTION REQUESTS (760) 777-7153
2004
BUILDING. PERMIT
CITY OF LA QUINTA '
Application Number . . .
Property Address
APN:
Application description
,Property Zoning . . . .
Application valuation
Owner
------------------------
LENNAR HOMES OF CALIFORNIA
78401,HIGHWAY 111, S.TE C
LA QUINTA, CA:
LA QUINTA CA 92253
[_0 4--0 0-0 0 4-5-9 1_x, Date 6/02/04
44750 VIA ALONDRA
604-032-999-74 -305212-
DWELLING - SINGLE FAMILY DETACHED
LOW DENSITY RESIDENTIAL
164957
Contractor
LENNAR HOMES'OF CALIFORNIA INC
78401 HIGHWAY 111, SUITE C
LA QUINTA CA 92253
WCC: OLD REPUBLIC IN
WC.: MWC10877600 11/01/04
CSLB: 728102 09/30/04
CCC: B
------ Structure Information -SFD --=--
Construction Type . . . . ...TYPE V - NON RATED
Occupancy Type . . . . . . DWELLG/LODGING/LONG;<=10-
Flood Zone . . . . . . NON -AO FLOOD ZONE
Other struct info . . . CODE EDITION 2001'CBC
FIRE SPRINKLERS NO
GARAGE SQ FTG 426.00
PATIO'SQ FTG 236.00
.NUMBER OF UNITS 1.00
FIRST FLOOR.SQ FTG 2683.00
----------------------------------------------------------------------------
Permit . . BUILDING PERMIT
Additional desc
Permit Fee 867.00 Plan Check Fee 563.55
Issue Date Valuation . . . . 164957
Qty Unit Charge Per Extension
BASE FEE 639.50
65.00 3.5000 THOU BLDG 100,001-500,000' 227.50
Permit MECHANICAL
Additional descl.
Permit Fee 52.50 Plan Check Fee 10.13
Issue Date . . . . Valuation . . . . 0
Qty Unit Charge Per
Extension
-- P.O. BOX
78-495 CALLE _.
LLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
Application Number:
Applicant:
Hppucanus mailing Address: b9L__11
or
VOICE (760) 777-701:
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date:
Architect or � En ineer's'Address.
19?D /
0 I U -M �+
S'A
Lic. No. �a 3 N5
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
Code, and my Licensin full force and effect.
/License Class_ I7 �se No. -7"1,0 —I
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or -herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
(--) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. . BA P.C. for this reason
Date - Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
d.Wg kers' camp nsation insurance cam' er,��Q p�)i num r are -
Cartier 17 A / oli Number / ��/�/ 1� f7cyoD
_ I certity that, in he performance of the work for which this permit is issued. I shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those provisions.
ate ` _P `� Applicant
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($700,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
I herebyaffirm under y perjury CONSTRUCTION LENDING AGENCY
penalty ofthat there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lenders Name
Lender's Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a
Permit 1. Each person upon whose behalf this application is made, each person at whose request and fto the conditions
hose benefit
rework snperfo s set frtned under or pursuaorth on this nt to any issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Ouinta, its
i t
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 daymt from date of issuance of such permit or
cessation of work for 180 days will subject permit to cancellation.
I certty that I have read this applicatiori and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes.
�/ nature (Applicant or Agent):
t
Page
2
Application
Number .
. .
. . 04-00004591
Date
6/02/04
- Qty
Unit Charge
Per
Extension
BASE
FEE
15.00
1.0.0
9.0000
EA
MECH
FURNACE <=100K
9.00
1.00
9.0000
EA
MECH
B/C <=3HP/100K BTU
9.00
'.00
16.5000
EA
MECH
B/C >3-15HP/>100K-500KBTU
00
2.00
6.5000
EA
MECH'VENT
FAN
13.00
1.00
6.5000
EA
MECH.EXHAUST
HOOD
6.50
------------------------------------
Permit .
. . . . .
-
ELEC-NEW RESIDENTIAL
---------------------------------------
Additional
desc
Permit Fee
117.4,3..
Plan Check Fee..
29.36 .
Issue Date
Valuation . . . .
0
Qty
Unit Charge
Per
Extension
BASE
FEE
15.00
2683.00
.0350
ELEC
NEW RES - 1,OR 2 FAMILY
93.91
426.00
.0200
ELEC
GARAGE OR NON-RESIDENTIAL
8.52
-----------------------------------------------------------------------------
Permit .
. . ... .
PLUMBING
Additional
desc
Permit Fee
171.75
Plan Check Fee
42.94
Issue Date
Valuation
0 `
Qty
Unit Charge
Per
Extension
BASE
FEE
15.00
17.00
6.0000
EA
PLB
FIXTURE
102.00
1.00
15.0000
EA
PLB
BUILDING SEWER
15.00
1.00
7.5000
EA
PLB
WATER HEATER/VENT
7.50
1.00
3.0000
EA
PLB
WATER INST/ALT/REP
3.00
1.00
9.0000
EA
PLB.LAWN
SPRINKLER SYSTEM
9.00
7.-00
7500
EA
PLB
GAS PIPE >=5
5.25
1'.00
15.0000
EA
PLB
GAS METER.
15'. 0 0
Permit
------------
GRADING PERMIT
Additional
desc
Permit Fee
15.00
Plan Check Fee
.00
Issue Date
Valuation
0
Qty
Unit Charge
Per
Extension
BASE
FEE
15.00
-------------------------------------_---------------------------------------
Special Notes and Comments.'
SFD - LOT
74. .PLAN 3.
PERMIT
DOES
NOT
Page3
Application Number"-
04-00004591 Date 6/02/04
Special Notes.and Comments
----------------------------
INCLUDE.BLOCK WALL,
POOL, SPA
OR
DRIVEWAY APPROACH.
Other Fees
ART IN PUBLIC PLACES -RES
00
DIF COMMUNITY_CENTERS-RES
97.00
DIF CIVIC CENTER - RES.
366.00
ENERGY REVIEW FEE
56.36.
DIF FIRE PROTECTION -RES
97.00
GRADING PLAN. CHECK FEE
.00
DIF LIBRARIES = RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
16..49
DIF_STREET; MAINT FAC -RES
15..00
DIF TRANSPORTATION"- RES
1098.00
Fee summary
Charged
Paid Credited
Due
Permit.Fee Total
1223.68
.00 .00
1223.68.
Plan•Check Total
645.98
.00 .00
645.98
Other Fee Total
2477.85
.00 .00
2471:85
Grand Total
4347.51
.00 .00
4347.51
HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 1 of 2 CF -6R
Site Address: 44-750 Via Alondra, La Quinta. Ca Permit Number:
Tract Number: 30521 Plan #: 3 Phase: 5
Lot Number: 74 Project: Del Oro Builder:. Lennar Homes
An installation certificate is required to be posted at the building site or made avalible for all appropriate inspections.
Atter completion of final inspection, a copy must be provided to the Building Department (upon request) and the building
owner at occupancy, per Section 10-103(b).
HVAC SYSTEMS:
Heatinq Equipment
of Efficiency Duct Heating Heating
Equip. CEC Certifiedr Name Identicle (AFUE, etc.) Location Duct Load Capacity
Type and Model Name Systems (>= CF -1 R) (attic, etc.) R -value (BTU / Hr) (BTU / Hr)
PC—YorkCompany YBS06OAl2UH1 attic -4
6
Coolinq Equipment
I, the undersigned, verity that egwpmei
efficient than that specified in the certifi
Efficiency Standards for residential buil
manufactured devices (from the ,�pplia
re,
above is: i) is the actual equipment instaned, z/ egwvaient to or more
;Yliance orm CF -1 R) submitted for compliance with the Energy
3 qui nt that meets or exceeds the appropriate requirements for
eoy e s or Paro)Avherp- applicable.
Team Heating & Air, Inc
Installing Subcontractor(Co. Name
OR General Contractor (Co. Name) OR Owner
MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT
Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage)
CFA:
System E—fj of
Indicate the maximum a owa le Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
x 400 x (Cooling Capacity in Nominal Tons) x (0.06)
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow x.06
uc Pressurization Test Results
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less) P:
T-24 Compliance Credit was Taken for TXV TXV was i
ystem M of
Indicate the maximum a owa le Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through.7 & 16
x 400 x (Cooling Capacity in Nominal Tons) i (0.06)
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow x .06
uc Pressurization Test Results
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less)
QT -24 Compliance Credit was Taken for TXV TXV wa:
PAGE 1
F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro
of Efficiency
Identicle (SEER, etc.)
Systems (>=CF -1 R)
Duct
Location Duct
(attic, etc.) R -value
Cooling Cooling
Load Capacity
(BTU / Hr) (BTU / Hr)
Equip. C C Certifiedr Name
Type and Model Number
York Company H2RCO362
a is
I, the undersigned, verity that egwpmei
efficient than that specified in the certifi
Efficiency Standards for residential buil
manufactured devices (from the ,�pplia
re,
above is: i) is the actual equipment instaned, z/ egwvaient to or more
;Yliance orm CF -1 R) submitted for compliance with the Energy
3 qui nt that meets or exceeds the appropriate requirements for
eoy e s or Paro)Avherp- applicable.
Team Heating & Air, Inc
Installing Subcontractor(Co. Name
OR General Contractor (Co. Name) OR Owner
MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT
Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage)
CFA:
System E—fj of
Indicate the maximum a owa le Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
x 400 x (Cooling Capacity in Nominal Tons) x (0.06)
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow x.06
uc Pressurization Test Results
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less) P:
T-24 Compliance Credit was Taken for TXV TXV was i
ystem M of
Indicate the maximum a owa le Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through.7 & 16
x 400 x (Cooling Capacity in Nominal Tons) i (0.06)
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow x .06
uc Pressurization Test Results
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less)
QT -24 Compliance Credit was Taken for TXV TXV wa:
PAGE 1
F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro
HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 2 of 2 CF -6R
Site Address: 44-750 Via Alondra, La Quinta. Ca Permit Number: 0
Tract Number: 30521
Lot Number: 74
Plan #: 3 Phase: 5
Project: Del Oro Builder: Lennar Homes
System of
Indicate the maximum aowa Ie Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity in Nominal Tons) x (0.06)
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow
TFEU Pressurization Test Results
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less)
-24 Compliance Credit was Taken for TXV
ys em E� of
Indicate the maximum aowa le Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity in Nominal Tons) x (0.06)
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow
uc Pressurization Test Results 2
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less)
24 Compliance Credit was Taken for TXV
ys em [� of
Indicate the maximum allowable Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06), for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity in Nominal Tons) x (0.06)
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow
E Pressurization Test Results
(UFM Q_C0 25 PTF -
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less) t
T-24 Compliance Credit was Taken for TXV
ysof
Indicate the maximum aowa le Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity in Nominal Tons) x (0.06)
21.7 x (Heating'Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow
DUF Pressurization Test Results 25
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less)
QT -24 Compliance Credit was Taken for TXV
x.06
x .06
x .06
x .06
TXV wa:
TXV was
TXV wa:
TXV was
I, the undersigned, verify that the above diagnostic test results and the work I performed associated with the test(s) is
in conformance with the requirements f mpli ce credit. (The builder shall provide the HERS provider a copy of the
CF -6R signed by the builder employe or ub- o acto rtifying that diagnostic testing and installation meet the
requirements for compliance credit.)
Team Heating & Air, Inc
Tests ignature,ns a ing Subcontractor(Co. Name
to ,
Performed OR General Contractor (Co. Name) OR Owner
COPY TO: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
PAGE 2
F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro
D
- =
ENERGY
Project Title
S 0%4=s
44-750 VIA ALONDRA LA QUINTA , CA.
Po. Box 621
Ph/Fax (760) 5642044
Rancho Mirage, CA 92270
Cell: (760] 250-1852
Email: DESNRG AAOL.COM
CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) CF -4R
LA QUINTA DEL ORO PH 5
03-02-05
Project Title
Date
44-750 VIA ALONDRA LA QUINTA , CA.
92253 LENNAR HOMES
Project Address
Builder Name
NACHO CASTENADA
760-578-6968 PLAN 3 2 UNITS
Builder Contact
Telephone Plan Number
RICHARD KROWN
760-250-1852 GROUP 4
HERS Rater
Telephone Sample Group Number
#CCNRK613292
03-14-05 74-5
Certifying Signature
Date Sample Lot Number'
Firm: DESERT ENERGY SERVICES LLC
HERS Provider: CHEERS
Street Address: P.O. BOX 621
City/State/Zip: RANCHO MIRAGE, CA. 92270
Copies to: Builder, HERS Provider
HERS RATER COMPLIANCE STATEMENT
The house was: ❑ Tested ® Approved as part of sample testing but was not tested
As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply
with the diagnostic tested compliance requirements as checked on this form.
❑ The installer has provided a copy of CF -6R (Installation Certificate.
❑ Distribution system is fully duoted(i.e., does not use building cavities as plenums or platform returns in lieu of ducts)
❑ Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth
backed, rubber adhesive duct tape to seal leaks at duct connections.
❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT
Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage)
Measured
Duct Pressurization Test Results (CFM @ 25 Pa) values ,
Test Leakage Flow in CFM
If fan flow is calculated as 400cfm/ton x number of tons enter calculated
value here
If fan flow is measured enter measured value here
Leakage Percentage (100 x Test Leakage/Fan Flow) _
Check Box for Pass or Fail (Pass=6% or less) ❑ ❑
Pass Fail
❑ THERMOSTATIC EXPANSION VALVE (TXV)
❑ Yes ❑ No Thermostatic Expansion Valve is installed and Access is
provided for inspection ❑ ❑