Loading...
BRES2017-0067LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that a licensed under provisions of Chapter 9 {commencing with Section 7000} of Division he Business and Professions Code, and my License is in full force and effect. License Class: B icense No.: 1019375 � -7 Date: "� -Z i / Contractor: - OWNER -BUILDER ECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031:5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the ; alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property; or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Caw does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' co ensation, as provided for by Section 3700 of the Labor Code, for the performance of t work for which this permit is issued. I`have and will maintain workers' compensation insurance, as required by Se i 3700 of the Labor Code, for the performance of the work for which this permit is is d. My workers' compensation insurance carrier and policy number are: Car r: EXEMPT Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shatntemploy any person in any marine so s to become subject to the workers' comation laws of California, and agree h , if I should become subject to the workers' compensation provisions of Section 00 of the Labor Code, I shall forthwith comply with those provisions. Date: " Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that t e- bove information is correct. I agree to comply with all city and county ordinances an s to laws relating to building construction, and hereby authorize representatives of th ty to enter upon the above- mentioned property for inspection purposes. Date: J �— Signature (Applicant or Agent): Ct I , VOICE (760) 777-7125 78-495 CALLE TAMPICO a .. V -` LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT FAX (760) 777-7011 . INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 5/25/2017 Application Number: BRES2017-0067 Owner: Property Address: 50365 VIA AMANTE LOU SCOLNIK APN: 776310043 50365 VIA AMANTE t2 Application Description: SCOLNIC / INTERIOR REMODEL AT BATHS, KITCHEN AND LIVING LA QUINTA, CA 92253 Property Zoning: Application Valuation: $65,000.00 a © o C7 N w Applicant: Contractor: ted j g o ROB PITCHFORD DESERT ESTATES DEVELOP ENT NC 77622 COUNTRY CLUB STE 0 78401 HWY 111 STE X GL_ ' PALM DESERT, CA 92211 LA QUINTA, CA 92253 (760)777-9920 Llc. No.: 1019375 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that a licensed under provisions of Chapter 9 {commencing with Section 7000} of Division he Business and Professions Code, and my License is in full force and effect. License Class: B icense No.: 1019375 � -7 Date: "� -Z i / Contractor: - OWNER -BUILDER ECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031:5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the ; alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property; or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Caw does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' co ensation, as provided for by Section 3700 of the Labor Code, for the performance of t work for which this permit is issued. I`have and will maintain workers' compensation insurance, as required by Se i 3700 of the Labor Code, for the performance of the work for which this permit is is d. My workers' compensation insurance carrier and policy number are: Car r: EXEMPT Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shatntemploy any person in any marine so s to become subject to the workers' comation laws of California, and agree h , if I should become subject to the workers' compensation provisions of Section 00 of the Labor Code, I shall forthwith comply with those provisions. Date: " Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that t e- bove information is correct. I agree to comply with all city and county ordinances an s to laws relating to building construction, and hereby authorize representatives of th ty to enter upon the above- mentioned property for inspection purposes. Date: J �— Signature (Applicant or Agent): ti Date: :5/25/2017 Application Number: BRES2017-0067. Owner: Property Address: 50365 VIA AMANTE LOU SCOLNIK APN: 776310043 50365 VIA AMANTE Application Description: SCOLNIC / INTERIOR REMODEL AT BATHS, KITCHEN AND LIVING LA QUINTA, to 92253 Property Zoning Application Valuation: $65,000.00 Applicant: Contractor: ROB PITCHFORD DESERT ESTATES DEVELOPMENT INC 77622 COUNTRY CLUB STE 0 78401 HWY 111 STE X PALM DESERT, CA 92211 LA QUINTA, CA 92253 (760)777-9920 Llc. No.: 1019375 Detail: INTERIOR REMODEL AT BATHS, KITCHEN AND LIVING.AREA [ENGINEERED] THIS PERMIT DOES NOT INCLUDE EXTERIOR SURFACE IMPROVEMENTS, ONLY EXTERIOR BBQAND ASSOCIATED ELECTRICAL INSTALLATION. 2016 CALIFORNIA BUILDING CODES. -DESCRIPTION ACCOUNT. I QTY I AMOUNT HOURLY CHARGE - YES ADMINISTRATIVE STAFF 101-0000-42600 0.25 $10.00 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER 101-0000-42600 1 $95.00 Total Paid for BLDG CITY STAFF - PER HOUR: $105.00 DESCRIPTION ACCOUNT QTY AMOUNT BSAS 561473 FEE 101-0000-20306 0 $3.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $3.00 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES/FIXTURES, ADDITIONAL 101-0000-42403 0 $75.90 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES/FIXTURES, ADDITIONAL PC 101-0000-42600 0 $18.907771 Total Paid for ELECTRICAL: $145.46 DESCRIPTION ACCOUNT QTY AMOUNT APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT APPLIANCE REPAIR/ALTERATION PC 101-0000-426000 $5.07 Total Paid for MECHANICAL: $17.74 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401• 0 $50.68 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $50.68 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.67 Total Paid for PLUMBING FEES: $126.70 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $22.80 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $18.24 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 100 SF 101-0000-42400 0 $51.68 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0• $141.36 Total Paid for REMODEL: $234.08 DESCRIPTION ACCOUNT QTY AMOUNT SMI.:- RESIDENTIAL 1010000-20308 0 $8.45 Total.Paid for STRONG MOTION INSTRUMENTATICIN SMI: $8.45 DESCRIPTION' ACCOUNT, QTY- AMOUNT TECHNOLOGY ENHANCEMENT FEE .502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $645.43 t BinOt-kF fy ofLa ulfla Building &r Safety Division Permit ;' 78-495 Calle Tampico aO��La Quinta, CA 92253 - (760) 777-701,2 lb�. 111 Building Permit Appiication and Tracking)Sheet Project Address Q — 3Fjs VC ��-f / a� Owner's Name: `1—A SC (1&( I 1�. A. P. Number: -7-70 10. 0G-3 Address: Legal DescriptioZ 9658— City, ST, Zip: L,4 QL0 ( &J7-4, Contractor: �y � z g Telephone:nc: �O Address: Project Description: City, ST, Zip:— el nc0 T eh o P C5 S State Lic. # : Linc. ##: _City ask--Ergr., Designer: VIE> Address: —77 City, ST, Zip:L� pT Telephone-Wo34 rO - Occupancy: Construction Type: Lia #: oState ect type (circle one), : New Add'n Alter Repair.air Demo Project ', Name of Contact Person: Sq. Pt_: # Stories: #Units: Telephone # of Contact Person `l&o -S.4 6 6 5 000 Estimated Value of Projec APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact $crson Plan Check Balance. Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrcctions/issue Electrical 'SubcontactorList Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person Pub. Wks.Appr Date or permit issue School Fees, I - Total Pcrmit Fces Ivo 1'�f34fro(L sC r Em" Assoc!a Desert Resort -Management PULL ,LUM t tovmowvver Assoc'Lc( WVL Architectural Application Decision May 15, 2017 Louis Scolnik & Joy Masoff PO Box 85 Litchfield, CT 06759 RE: Architectural Application 50365 Via Amante Dear Homeowners: Your architectural application to install a custom courtyard gate and to replace the glass blocks with clear glass in the casita bathroom has been APPROVED by the Architectural Committee as submitted. Please note, the. Association has no opinion regarding the interior renovations as it has no jurisdiction over. any changes, not visible from the common area. We thank you for your patience in this . process, and providing all the required documentation and applications. If you have any questions,, please give . me a call at (760) 346-1161 ext.145 or email at Lcicogna@drminternet.com. Sincerely, ' Leslee Cicogna, PCAM, AMS, CMCA Community Association Manager On Behalf of the Architectural Committee Palmilla Homeowners Association RECEIVED. MAY. 1 5 2017 CITYY OF LA QUINTA " COMMUNITY DEVELOPMENT 5' BUILDING ENERGY ANALYSIS REPORT PROJECT: Scolnik Residence 50-365 Via Amante La Quinta, CA 92253 Project Designer: { Robert A. Pitchford Design and Drafting 77-622 Country club STE O Palm wDesert, CA 92260 (760) 346-2856 Report Prepared by: Jon d. Scott Scott Design and Title 24, Inc, 74-818 Velie Way STE 8 Palm Desert, CA 92260 760-200-4780 MAW— CITY OF LA QUINTA BUILDING & SAFETY DEPT, APPROVED FOR CONSTRUCTION Job Number: RECEIVE[ DATES 201 BY �31D6�� • �� . Date: APR 14 2011 3/31 /2017CITY OF LA QUINTA COMMUNITY DEVELOPMEP The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. CERTIIPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project 'PE Scolnik Ca culation Date/Time: 09:21, Fri, Mar 31, 2017 1 Calculation Description: Title 24 Analysis Input File Name: Scolnik-Pitchford-17.ribdl6x CF•RF-01 Page 1 of 8 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Scolnik 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 50-365 Via Amante Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.2.1 (695) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.1 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 315 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 3141 15 Number of Zones 2 16 Slab Area (ft) 3141 17 Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (ft) 0 21 Glazing Percentage (%) 24.1% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shown below REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Pipe insulation, all lines Registration Number: Registration DateMme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-31 09:22:52 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 6.66 6.80 -0.14 -2.1% Space Cooling 294.14 291.92 2.22 0.8% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 6.83 6.83 0.00 0.0% Photovoltaic Offset — 0.00 0.00 -- Compliance Energy Total 307.63 305.55 2.08 0.7% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Pipe insulation, all lines Registration Number: Registration DateMme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-31 09:22:52 CERTIIPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE qjOD Project 'PE Scolnik ation Date/Time: 09:21, Fri, Mar 31, 2017 Calculation Description: Title 24 Analysis Input File Name: Scolnik-Pitchford-17.ribdl6x CF*RF-01 Page 2 of 8 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications_: --None— Cooling System Verifications: V - None - VAC Distribution System Verifications: -- None -- Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION - • - •. _ . 01. 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Scolnik 3141 1 3 2 0 1 ZONE -INFORMATION, 01 ?J`. 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height . Water Heating System 1 Water Heating System 2 Residence Conditioned HVAC1 2877 9 DHW Sys 1 casita Conditioned HVAC2 264' 9 DHW Sys 1 Registration Number: Registration DateTme: HERS Provider: CA Building Energy Efficiency Standards - 2.016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-31 09:22:52 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE tIOD Project Name: Scolnik Calculation DatelTime: 09:21, Fri, Mar 31, 2017 Calculation Description: Title 24 Analysis Input File Name: Scolnik-Pitchford-1 7.ribd 1 6x CF&RF-01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition N Wall Residence R-13 Wall 0 45 688 43.5 90 Existing No E Wall Residence R-13 Wall 90 135 826 67 90 Existing No S Wall Residence R-13 Wall 180 225 688 379 90 Existing No SW Wall Residence R-13 Wall • 225 Right 144 24 90 Existing No W Wall Residence R-13 Wall 270 315 826 123 90 Existing No NW Wall Residence R-13 Wall 315 Front 342 28 90 Existing No Roof Residence Defaul: 1978 to present 2877 Existing No N Wall 2. casita R-13 Wall 0 45 388 16.2 90 Existing No E Wall 2 casita R-13 Wall 90 135 388 16.2 90 Existing No SE Wall casita R-13 Wall 135 Back 144 0 90 Existing No S Wall 2 casita R-13 Wall 180 225 388 48 90 Existing No W Wall 2 casita R-13 Wall 270 315 388 10.8 1 90 1 Existing No Roof 2 casita Defaul: 1978 to present 264 Existing No ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Residence Attic RoofResidence Ventilated 3 0.1 0.85 No No Existing No Attic casita Attic Roofcasita Ventilated 3. 0.1 0.85 No No Existing No Registration Number: Registration Date[Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-31 09:22:52 CERTI'PE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Ca Project 'PE Scolnik Ca culation Date/Time: 09:21, Fri, Mar 31, 2017 Calculation Description: Title 24 Analysis Input File Name: Scolnik-Pitchford-17.ribdl6x CF -ORF-01 Page 4 of 8 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition ex' N Wall (- specify --0) -- - 1 24.0 0.71 0.60 Insect Screen (default) Existing No ex 2 N Wall (- specify --0) -- - 1 19.5 0.71 0.60 Insect Screen (default) Existing No ex 3 E Wall (- specify -90) -- - 1 27.0 0.71 0.60 Insect Screen (default) Existing No ex 4 E Wall (- specify -90) -- -- 1 40.0 0.71 0.60 Insect Screen (default) Existing No alt S Wall (- specify -180) -- - 1 54.0 0.33 0.19 Insect Screen (default) Altered N/A ex 5 S Wall (- specify -180) -- -- 1 81.0 0.71 0.60 Insect Screen (default) Existing No ex 6 S Wall (- specify -180) -- -- 1 24.0 0.71 0.60 Insect Screen (default) Existing No ex 7 S Wall (-specify -180) -- - 1 160.0 0.71 0.60 Insect Screen (default) Existing No ex 8 S Wall (- specify -180) -- -- 1 60.0 0.71 0.60 Insect Screen (default) Existing No ex 9 SW Wall (Right -225) -- - 1 24.0 0.71 0.60 Insect Screen (default) Existing No ex 10 W Wall (- specify -270) - - 1 24.0 0.71 0.60 Insect Screen (default) Existing No ex 11 W Wall (- specify -270) -- - 1 40.0 0.71 0.60 Insect Screen (default) Existing No ex 12 W Wall (- specify -270) -- -- 1 48.0 0.71 0.60 Insect Screen (default) Existing No ex 13 W Wall (- specify -270) -- -- 1 11.0 0.71 1 0.60 Insect Screen (default) Existing No ex 14 NW Wall (Front -315) -- -- 1 28.0 0.71 0.60 Insect Screen (default) Existing No alt 2 N Wall 2 (- specify -0) - -- 1 16.2 0.33 0.19 Insect Screen (default) Altered N/A alt 3 E Wall 2 (- specify --90) -- - 1 16.2 0.33 0.19 ' Insect Screen (default) Altered N/A ex 15 S Wall 2 (- specify -180) - - 1 48.0 0.71 0.60 Insect Screen (default) I Existing I No ex 16 W Wall 2 (-specify --270) - - 1 10.8 0.71 1 0.60 Insect Screen (default) I Existing No Registration Number: Registration Dateffime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-31 09:22:52 CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project ame: Scolnik Ca culation Date/Time: 09:21, Fri, Mar 31, 2017 Calculation Description: Title 24 Analysis Input File Name: Scolnik-Pitchford-17.ribd16x C*RF-01 Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 09 Name Zone Total Cavity Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 212 None '0.8 No Existing No • Cavity/ Frame: no insul. /2x4 Top Chid casita 264 101 2x4 Top Chord of Roof Truss @ 24 0.8 No Roof Deck: Wood Siding/sheathing/decking Attic RoofResidence Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Defaul: 1978 to present attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R11 0.083 Over Ceiling Joists: R-1.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.101 Exterior Finish: 3 Coat Stucco • Cavity/ Frame: no insul. / 2x4 Top Chid 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofcasita Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Slab -on -Grade Residence 2877 212 None '0.8 No Existing No Slab -on -Grade ex casita 264 101 None 0.8 No Existing No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation'of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required -- WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction M) Status Verified Existing Condition DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 Annual Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-31 09:22:52 CERTIf E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project ame: Scolnik Ca culation Date/Time: 09:21, Fri, Mar 31, 2017 Calculation Description: Title 24 Analysis Input File Name: Scolnik-Pitchford-17.ribdl6x CFP&RF-01 Page 6 of 8 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Energy Factor or Efficiency Input Rating/Pilot Tank Insulation R -value (Int/Ext) Standby Loss / Recovery Eff NEEA Heat Pump Type Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 1 50 0.61 EF 40000 Btu/hr n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 CntrfFurnace - Fuel -fired central furnace 80 AFUE Heating System Cooling System 80 AFUE EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 No No N/A Distribution Fan - Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 2877 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC2 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 264 Existing No Cooling System Component 2 Component 2 System 2 2 HVAC- HEATING SYSTEMS 01 02 01 02 03 Name Type Efficiency Heating Component 1 CntrfFurnace - Fuel -fired central furnace 80 AFUE Heating Component 2 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Efficiency Zonally Controlled Multi -speed Compressor Name System Type EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 No No N/A system. Cooling Component 2 SplitAirCond - Split air conditioning 10 12 No No N/A system Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-31 09:22:52 CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project ame: Scolnik Ca culation Date/Time: 09:21, Fri, Mar 31, 2017 Calculation Description: Title 24 Analysis Input File Name: Scolnik-Pitchford-17.ribd16x CF*RF-01 Page 7 of 8 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic . Existing (not (Ventilated and 6.0 Attic Attic None Existing No N/A System 1 Unventilated) specified) Air Distribution Ducts located in attic (Ventilated and Existing (not 6.0 Attic Attic None ' Existing No N/A System 2 Unventilated) specified) IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required l - Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 HERS Provider: Report Generated at: 2017-03-31 09:22:52 CERTIf�E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project ame: Scolnik Ca culation Date/Time: 09:21, Fri, Mar 31, 2017 Calculation Description: Title 24 Analysis Input File Name: Scolnik-Pitchford-17.ribdl6x CF&RF-01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Jon d. Scott Company: Signature Date: Scott Design and Title 24, Inc, 3/31/2017 Address: CEA/HERS Certification Identification (If applicable): 74-818 Velie Way STE 8 city/Staten:m Desert, CA 92260 Phone: 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT 1 certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the in ation provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval wit ui i i 1p!iPation. Responsible Designer Name: Robert A. Pitchford es e D ' Company: ate Signed. Robert A. Pitchford Design and Drafting 3 1-7 Address: 77-622 Country club STE O License: City/State/Zip: Palm Desert, CA 92260 Phone: (760) 346-2856 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-31 09:22:52 r ---q L- • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Scolnik Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family 10 Existing+ Addition/Alteration Date 3/31/2017 Project Address 50-365 Via Amante La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,141 Addition 0 # of Units 1 INSULATION Construction Type Area Cavity fe) Special Features Status Roof Wood Framed Attic R11 3,141 Existing Wall Wood Framed R 13 6,038 Existing Slab Unheated Slab -on -Grade - no insulation 3,141 Perim = 313' Existing Demising Wood Framed R 19 467 Existing FENESTRATION Orientation Area(ft) I Total Area: 756 Glazing Percentage: 24.1 % U -Fac SHGC Overhang Sidefins New/Altered Average U -Factor: 0.33 Exterior Shades Status Front (N) 43.5 0.710 0.60 none none Bug Screen Existing Left (E) 67.0 0.710 0.60 none none Bug Screen Existing Rear (S) 54.0 0.330 0.19 none none Bug Screen Altered Rear (S) 373.0 0.710 0.60 none none Bug Screen Existing Right (SW) 24.0 0.710 0.60 none none Bug Screen Existing Right (lq 133.8 0.710 0.60 none none Bug Screen Existing Front (NM 28.0 0.710 0.60 none none Bug Screen Existing Front (N) 16.2 0.330 0.19 none none Bug Screen Altered Left (E) 16.2 0.330 0.19 none none Bug Screen Altered HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing 1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status HVAC Ducted Ducted Attic 6.0 Existing HVAC Ducted Ducted Attic 6.0 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnerqyPro 7.1 by EnerqySoft User Number: 6712 /D: Pae 11 of 19 41 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. (Original 0812016) Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfmlft' or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 10i/I.S.21A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U -factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 1 10.8 i when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U -factor must not exceed 0.043. Minimum R-19 or weighted average U -factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.* § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R -value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or U -factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly U -factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.* § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U -factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). § 150.0(8)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U -factor of 0.58; or the weighted averse LI -factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)lC: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.* § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTUlhr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btulhr are exempt); and pool ands a heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in § 150.0(h)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A- Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)36: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.06)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the iriternal insulation R -value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.06)2A. Distribution piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by . § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)36: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class 11 vapor retarder. ^ Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows'natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units `must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification •that Corporation SRCC orb a Iistin agency is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC): If a ` contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0; 602.0, 603.0, 604.0,605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)l: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1816 or aerosol sealant that meets the requirements of UL 7231f mastic or tape is used to seal openings greater than X. inch, the combination of mastic and, either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials othr than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross-sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,' mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)g: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts'must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0(m) 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,' pressure drop, and labeling requirements of § 150.0 m 12. 4 4 2016 Low -Rise ,Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:r. 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(0): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)18: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fanspeed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).* Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5(f); and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5(f); and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9 and complies with all other applicable requirements in § 150.0(k)2. 4 4 a 2016 Low -Rise Residential Mandatory Measures Summary 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled b a vacancysensor. F§ § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0(k)3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of ower as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the rSol,aor.Ready 0(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the re uirements of 110.10 b throw h 110.10 e . 0(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)l: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 1 10.10 c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". 0 F— LL-- 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name colnik Residence Date 3/31/2017 System Name HVAC Floor Area 2,877 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 3,300 0 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 63,212 3,239 1,552 54,743 Total Output Btuh 71,000 0 Output Btuh/s ft 24.7 4,314 3,158 Cooling System 0 0 Output per System 48,000 0 0 0 0 Total Output Btuh 48,000 0 3,239 0 Total Output Tons 4.0 4,314 31158 Total Output Btuh/s ft 16.7 Total Output s ft/Ton 719.3 1 71,839 61,058 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Exist. HVAC 37,021 4,082 71,000 Airflow cfm/s ft 0.56 Airflow (cfm/Ton), Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 37,021 4,082 71,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 68 OF Return Fan QD 68 OF 105 OF f� Heating Coil Supply Fan 1,600 cfm 68 of 1,400 cfm 105 OF ► ���!—���---� 103 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak 112/78°F 77/63°F 55/54°F 55/54°F Outside Air Ar 0 cfm Cooling Coil Supply Fan 57 / 55 OF 1,600 cfm �- 48.2% ' ROOM Return Fan R`Y. 77 / 63 OF 77 / 63 OF 75 / 62 OF 1,400 cfm U-1�I-EJU ; EnergyPro 7.1 by EnergySoft User Number: 6712 /D: Page 16 of 19 • 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Scolnik Residence Date 3/31/2017 System Name HVAC Floor Area 264 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 485 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 10,106 297 385 14,157 Total Output Btuh 71,000 0 Output Btuh/s ft268.9 690 817 Cooling System 0 0 Output per System 48,000 0 0 0 0 Total Output Btuh 48,000 0 1 690 1 11,486 297 0 Total Output Tons 4.0 817 Total Output Btuh/s ft 181.8 Total Output s ft/Ton 66.0 15,790 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Exist. HVAC 36,403 3,987 71,000 Airflow cfm/s ft 6.06 Airflow cfm/Ton 400.0 Outside Air % 0.0% Total Adjusted System Output 1 36,403 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 3,987 Aug 3 PM 71,000 F Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF 105 OF 105 OF Outside Air Hz---i--L-L- 0 cfm Healing Coil Supply Fan 1,600 cfm 70 of Return Fan 70 of d [D— --1— 0 4 1,400 cfm U a 105 F ROOM 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak) 112/78°F 75162°F 55/54°F 55/54°F Outside Air - 11 0 cfm Cooling Coil Supply Fan 55 / 54 OF 1,600 cfm 46.3 % ROOM Return Fan 75/62°F 75/62°F 75/61 OF � 1400 cfm LE EnergyPro 7.1 by EnergySoft User Number 6712 /D: Page 17 of 19 ZONE LOAD SUMMARY Project Name Scolnik Residence Date 3/31/2017 System Name HVAC Floor Area 2,877 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Residence 1.0 0 Aug 3 PM 3,300 63,212 3,239 1,552 54,743 TOTALS 01 0 0 01 Aug 3 PM 1 63,212 3,239 54,743 (BLOCK LOAD EnergyPro 7.1 by EnergySoft User Number: 6712 ID: r Page 18 of 19 ZONE LOAD SUMMARY Project Name Scolnik Residence Date 3/31/2017 System Name HVAC Floor Area 264 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible casita 1.0 0 Aug 3 PM 485 10,106 297 385 14,157 TOTALS 0 0 0 0 Aug 3 PM 1 10,106 297 14,157 (BLOCK LOAD) EnergyPro 7.1 by EnergySoft User Number: 6712 ID: Page 19 of 19