Loading...
BRES2014-1081Applicant: Contractor: MONARCH HOMES MONARCH HOMES 49950 JEFFERSON STREET 49950 JEFFERSON STREET LA QUINTA, CA 92264 LA QUINTA, CA 92264 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am I' d under provisions of Chapter 9 (commencing with Section 7000) of Division a siness and Professions Code, and my License is in full force and effect. License Class: License No.: C28860 Date: V Contractor: I 4r rJLIsT %Aca OWNER -BUILDER CLARA I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division ? of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements' are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec: , B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that.there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's (760)413-8863 Llc. No.: C28860 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, shall not employ any person in any manner come subject to the workers'. compensation laws of California, and agr th , if I sh Ld become subject to the . workers' compensation provisions of S ction 3 0 o e L bor Code, I shall forthwith comply with those provisions.Date. 21 p WARNING: FAILURE TO SECURE WORKERS' CCOMPC1VSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is notcommenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state thatMins correct. I agree to comply with all city and county ordinances ao building construction, and hereby authorize representatives of he above- mentioned property for inspection purposes. Dat/2�Signature (Applicant or Agen 0 Nvw.rr D ✓ .,.- - - '^ fry, ; J..� f VOICE (760) 777-7125 78-495 CALCE TAMPICO 0 D LA QUINTA, CALIFORNIA 92253 COMMUNI I DEVFRPMEN FAX (760) 777-7011 NT INSPECTIONS (760) 777-7153 8 W"D T - ,1AIV� F �r,5 Date: 1/21/2015 Application Number: BRES2014-1081 Owner: Property Address: 80110 VIA CAPRI . p y ROBERT MCDONALD APN: 777100065 � COMMUNITY 11 L mEENT DEPARTMENT 2110 A BOCA RATON NO 206 . Application Description: MC DONALD RESIDENCE NEW SFD AUSTIN, TX 0 Property Zoning: Application Valuation: $586,195.50 Applicant: Contractor: MONARCH HOMES MONARCH HOMES 49950 JEFFERSON STREET 49950 JEFFERSON STREET LA QUINTA, CA 92264 LA QUINTA, CA 92264 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am I' d under provisions of Chapter 9 (commencing with Section 7000) of Division a siness and Professions Code, and my License is in full force and effect. License Class: License No.: C28860 Date: V Contractor: I 4r rJLIsT %Aca OWNER -BUILDER CLARA I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division ? of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements' are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec: , B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that.there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's (760)413-8863 Llc. No.: C28860 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, shall not employ any person in any manner come subject to the workers'. compensation laws of California, and agr th , if I sh Ld become subject to the . workers' compensation provisions of S ction 3 0 o e L bor Code, I shall forthwith comply with those provisions.Date. 21 p WARNING: FAILURE TO SECURE WORKERS' CCOMPC1VSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is notcommenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state thatMins correct. I agree to comply with all city and county ordinances ao building construction, and hereby authorize representatives of he above- mentioned property for inspection purposes. Dat/2�Signature (Applicant or Agen 0 Nvw.rr D t FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT'' PAID PAID DATE ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $965.49 $965.49 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA Total Paid'forART IN PUBLIC PLACES - AIPP: $965.49 $965.49 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS S131473 FEE 101-0000-20306 0 $24.00 $24.00 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $24.00 $24.00 DESCRIPTION ACCOUNT QTY AMOUNT" PAID PAID DATE DIF - CIVIC CENTER 252.0000-43200 0 $942.00 $942.00 • 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 $129.00 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $433.00 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - LIBRARIES 253-0000-43200 0 $344.00 $344.00 1/21/15 PAID BY METHOD RECEIPT # ' CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF _ PARK MAINTENANCE 256-0000-43200 0 $40.00 $40.00 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $2,048.00 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA „ DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00. $116.00 1/21/15 PAID BY METHOD RECEIPT # CHECK #" CLTD BY' MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $2,842.00 1/21/15 PAID BY METHOD - RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $6,894.00 DESCRIPTION r ACCOUNT. QTY AMOUNT PAID " PAIDMATE TEMP POWER SERVICE 101-0000-42403 0 $23.83 $23.83 1/21/15 PAID BY METHOD RECEIPT # CHECK # ' CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE TEMP POWER SERVICE PC 101-0000-42403 0 $16.68 $16.68 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA Total Paid for ELECTRICAL: $40.51 $40.51 DESCRIPTION ACCOUNT � QTY AMOUNT PAID PAID DATE RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $85.12 $85.12 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $35.07 $35.07 1/21/15 PAID BY. METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION • ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $143.00 $143.00 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 • 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.19 $47.19 1/21/15 PAID BY METHOD RECEIPT #; CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA Total Paid for ELECTRICAL - NEW CONSTRUCTION: i $310.38 $310.38 DESCRIPTION ' ACCOUNT QTY AMOUNT PAID 'PAID DATE RESIDENTIAL FINISH GRADING PC 101-0000-42600 I. 0 $143.00 $143.00 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA Total Paid forGRADING: $143.00 $143.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE AIR HANDLER 101-0000-42402 0 $71.50 $71.50 1/21/15 PAID BY METHOD RECEIPT#- CHECK # CLTD"BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE AIR HANDLER PC 101-0000-42600 0 $23.84 $23.84 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCR PTION ACCOUNT Q AMOUNT PAID PAID E CONDENSER/COMPRESSOR 101-0000-42402 0/ $214.50 $214.50 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID • " -PAID DATE CONDENSER/COMPRESSOR PC 101-0000-42600 0 $142.98 $142.98 1/21/15 ' PAID BY,. METHOD RECEIPT # CHECK # CLTD BY . MONARCH HOMES CHECK R34S4 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT- PAID PAID,DATE EXHAUST HOOD 101-0000-42402 0 $11.92 $11.92 1/21/15 PAID BY a METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R34S4 6003 MFA DESCRIPTION , ACCOUNT QTY' AMOUNT -PAID PAID DATE EXHAUST HOOD PC 101-0000-42600 0 $4.77 $4.77 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID'DATE. FURNACE 101-0000-42402 0 $214.50 $214.50 1/21/15 PAID BY METHOD RECEIPT .# CHECK # CLTD BY, MONARCH HOMES CHECK R34S4 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FURNACE PC 101-0000-42600 0 $142.98 $142.98 1/21/15 PAID BY METHOD RECEIPT # CHECK # , CLTD BY MONARCH HOMES CHECK R34S4 6003 MFA . DESCRIPTION ACCOUNT QTY AMOUNT- , PAID PAID DATE VENT FAN' 101-000042402 0 $143.04 $143.04 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID .• ,PAID DATE VENT FAN PC 101-0000-42600 0 $57.24 $57.24 1/21/15 PAID BY METHOD ' RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK ` R34S4 6003 MFA Total Paid for MECHANICAL: $1,027.27 $1,027.27 DESCRIPTION - ACCOUNT QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PERMIT 101-0000-42400 0 $790.15 $790.15 1/21/15 PAID BY METHOD RECEIPT,# CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA' Total Paid forNEW CONSTRUCTION PERMIT: $790.15 $790.15 DESCRIPTION b. ACCOUNT QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $206.99 $206.99 1/21/15 PAID BY'- ' METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 '6003 MFA DESCRIPTION ACCOUNT.. QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,500.00 $1,500.00 8/5/14 PAID BY METHOD RECEIPT # ', CHECK #' "' CLTD BY MONARCH HOMES CHECK R616 1652 SKH , Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,706.99 $1,706.99 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BACKFLOW DEVICE 101-0000-42401 0 $11.92 ' $11.92 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BACKFLOW DEVICE PC 101-0000-42600 0 $4.77 $4.77 1/21/15 PAID BY METHOD , -RECEIPT # CHECK # CLTD BY. MONARCH HOMES CHECK- R3454 6003 MFA DESCRIPTION ACCOUNT i, CITY' AMOUNT 4 PAID PAID DATE. BUILDING SEWER 101-0000-42401 0 $11.92 $11.92 1/21/15 PAID BY = METHOD RECEIPT # CHECK # CLTD BY. MONARCH HOMES CHECK R3454 6003 MFA ',DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BUILDING SEWER PC 101-0000-42600 0 $11.92 $11.92 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY. MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP 101-0000-42401 0 $357.60 $357.60 1/21/15 PAID BY METHOD - RECEIPT #" CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT - .'PAID PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $357.60 $357.60 1/21/15 PAID BY ;METHOD RECEIPT #, CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA' DESCRIPTION ACCOUNT QTY" AMOUNT PAID PAID DATE GAS SYSTEM, S+ OUTLETS 101-0000-42401 0 $35.75 $35.75 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $23.83 $23.83 1/21/15 PAID BY METHOD. RECEIPT•# , CHECK # CLTD BY. MONARCH HOMES CHECK ` 113454 6003 _ MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER HEATER/VENT 101-0000-42401 0 $23.84 $23.84 1/21/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ACCOUNTQTY AMOUNT PAID PAID DATE + WATER HEATER/VENT PC 101-0000-42600 U $14.3014.30 1/21/15 PAID. BY �, � METHOD RECEIPT #�� <, .% CHECK # ,_'" :CLTD, BY. ' MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION',. : ' •' ACCOUNT.:_ QTY AMOUNT PAID ` x PAID DATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $11.92 $11.92 1/21/15 t.. PAID BYti METHOD, ' RECEIPT # CHECK # CCTD BY - MONARCH HOMES CHECK R3454 6003 MFA DESCRIPTION ` _, .� -, ACCOUNT; 3 ,QTY': ='_ AMOUNT PAID' PAID.DATE WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $11.92 $11.92 .1/21/1S PAID BY _ .. ': METHOD RECEIPT #,! CHECK #_ CLTD BY MONARCH HOMES CHECK R3454 6003 MFA Total Paid for PLUMBING FEES: $877.29 $877.29 DESCRIPTION •' ACCOUNT �:,a" QTYF AMOUNT `' PAID: PAID DATE. SMI - RESIDENTIAL 101-0000-20308 0 $76.21 $76.21 1/21/15 , PAID BY *' METHOD - RECEIPT # : CHECK # _ CLTD BY MONARCH HOMES + CHECK R3454 6003 MFA Total Paid forSTRONG MOTION INSTRUMENTATION SMI: .$76.21 $76.21 ES DCRIPTION ACCOUNT , 'QTY AMOUNT r, PAID PAID DATE SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 $1,837.44 1/21/15 PAIDBY METHOD • 'RECEIPT# !CHECK # CLTD.BY'. MONARCH HOMES CHECK R3454 .6003 MFA Total Paid forTUMF - RESIDENTIAL: $1,837.44 $1,837.44 TOTALS: $14,692.73 $14,02.73 i • J CALLED ALBERS CONST. @760-774-8787 PLANS READY TO ISSUE. ITEMS NEEDED P.M. 10, SCHOOL FEES, GRAND DEED, TELEPHONE CALL JIM JOHNSON. 1/13/2015 1/13/2015 HOA LETTER,GRADING PLAN NOT SIGNED, CONTRACTORS LIC.- NEED IC:NEED 5 TO BE UPDATED. NAMETYPE NAME "ADDRESSI CONTACTS CITY STATE ZIP' PHONE ::FAX EMAIL APPLICANT- ALBERS CONSTRUCTION CO INC P 0 BOX 238 LA QUINTA CA 92247 (760)771-9954 $15.00 CONTRACTOR ALBERS CONSTRUCTION CO INC P 0 BOX 238 LA QUINTA CA 92247 (760)771-9954 Total Paid for BUILDING STANDARDS ADMINISTRATION $15.00 $15.00 OWNER JACLIN C. SMITH 302 E. WEDGEWOOD SPOKANE WA 99208 (760)771-9954 R3425 • • 'DESCRIPTION"' "ACCOUNT ` QTY AMOUNT PAID = PAID DATE RECEIPT #+ CHECK # METHOD:. 4=� PAID BY, r . CLTD 14 ART IN PUBLIC PLACES - 270-0000-43201 0 $382.17 $382.17 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA RESIDENTIAL Total Paid forART IN PUBLIC PLACES - AIPP: $382.17 $382.17 BSAS SB1473 FEE 101-0000-20306 0 $15.00 $15.00 .1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA Total Paid for BUILDING STANDARDS ADMINISTRATION $15.00 $15.00 BSA: DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $942.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA DIF -COMMUNITY 254-0000-43200 0 $129.00 $129.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA CENTERS DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $433.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA DIF - LIBRARIES 253-0000-43200 0 $344.00 $344.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA DIF - PARK 256-0000-43200 0 $40.00 $40.00 1/15/15 R3425 7021. CHECK JACLIN C. SMITH AZA MAINTENANCE DIF - PARKS/REC 251-0000-43200 0 $2,048.00' $2,048.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA' DIF - STREET 255-0000-432000 $116.00 $116.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA MAINTENANCE Printed: Wednesday,.January 21, 2015 4:01:16 PM 2 of 6 C SYS7Eh1S Printed: Wednesday, January 21, 2015 4:01:16 PM 3 of 6 SYSTEMS -.- ,----w- ---�------------- JRECEIPT "CHECK . _ "PAID DESCRIPTION r :=ACCOUNT QTY AMOUNT PAID PAID # # ' METHOD BY {CBY DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $2,842.00 1/15/15 113425 7021 CHECK JACLIN C. SMITH AZA Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $6,894.00 TEMP POWER SERVICE 101-0000-42403 0 $24.17 $24.17 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA TEMP POWER SERVICE 101-0000-42403 0 $16.92 $16.92 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA PC Total Paid forELECTRICAL: $41.09 $41.09 RESIDENTIAL, EA 101-0000-42403 0 $73.98 $73.98 1/15/15 R3425 7.021 CHECK JACLIN C. SMITH AZA ADDITION 1,000SF RESIDENTIAL, EA 101-0000-42600 0 $30.48 $30.48 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA ADDITION 1,000SF, PC RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $145.03 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA 1,000SF RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $47.86 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA 1,000SF, PC Total Paid for ELECTRICAL- NEW CONSTRUCTION: $297.35 $297.35 RESIDENTIAL FINISH 101-0000-42600 0 $143.00 $143.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA GRADING PC Total Paid forGRADING: $143.00 $143.00 CONDENSER/COMPRES 101-0000-42402 0 $181.30 $181.30 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA SOR CONDENSER/COMPRES 101-0000-42600 0 $120.85 $120.85 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA SOR PC EXHAUST HOOD 101-0000-42402 0 $24.18 $24.18 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA EXHAUST HOOD PC 101-0000-42600 0 $9.66 $9.66 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA FURNACE 101-0000-42402 0 $181.30 $181.30 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA FURNACE PC 101-0000-42600 0 $120.85 $120.85 1/15/15 R3425 7021 CHECK JACLIN C. SMITH, AZA VENT FAN 101-0000-42402 0 $72.54 $72.54 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA Printed: Wednesday, January 21, 2015 4:01:16 PM 3 of 6 SYSTEMS DESCRIPTION "-ACCOUNT QTY' AMOUNT PAID t" ' .PAID DATE -RECEIPT CHECK METHOD ,PAID BY'w CLTD BY x J _- r _. �• 4 _.� m az „s VENT FAN PC 101-0000-42600 0 $28.98 $28.98 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA Total Paid for MECHANICAL: $739.66 $739.66 MULTI -SPECIES 101-0000-20310 0 $1,292.00 $1,292.00 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA RESIDENTIAL 0-8 UNITS Total Paid forMULTI-SPECIES RESIDENTIAL $1,292.00 $1,292.00 NEW CONSTRUCTION 101-0000-42400 0 $667.25 $667.25 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA PERMIT Total Paid for NEW CONSTRUCTION PERMIT: $667.25 $667.25 NEW CONSTRUCTION 101-0000-42600 0 $1,428.60 $1,428.60 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA PLAN CHECK ALBERS NEW CONSTRUCTION', 101-0000-42600 0 $1,400.00 $1,400.00 10/22/14 R2311 3839 CHECK CONSTRUCTION CO SKH PLAN CHECK INC NEW CONSTRUCTION 101-0000-42600 0 $28.60 $28.60 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA PLAN CHECK " Total Paid forNEW CONSTRUCTION PLAN CHECK: $2,857.20 $2,857.20 BACKFLOW DEVICE 101-0000-42401 0 $12.09 $12.09 '1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $4.83 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA BUILDING SEWER 101-0000-42401 0 $12.09 $12.09 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA BUILDING SEWER PC 101-0000-42600 0 $12.09 $12.09 1/15/15 R3425 7021 CHECK, JACLIN C. SMITH AZA FIXTURE/TRAP 101-0000-42401 0 $278.07 $278.07 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA FIXTURE/TRAP PC 101-0000-42600 0 $278.07 $278.07 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA GAS SYSTEM, 5+ 101-0000-42401 0 $36.26 $36.26 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA ' OUTLETS GAS SYSTEM, 5+ 101-0000-42600 0 $24.17 $24.17 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA OUTLETS PC WATER HEATER/VENT 101-0000-42401 0 $36.27 $36.27 1/15/15 R3425 7021 CHECK JACLIN C. SMITH AZA Printed: Wednesday, January 21, 2015 4:01:16 PM A of 6 CRWIYSTEMS I(/�� �I4^ "PO � Cv P.O. BOX 1504 APPLICATION ONLY Building i 78-495 CALLE TAMPICO Address / Q LA QUINTA, CALIFORNIA 92253 Owner L Sfdcill(x= BUILDING: TYPE CONST. OCC. GRP. Mailing o/v/4tpnl/}e. t! r�tt f 7 7 % - .' DO — o (,PS Address.�js0 Sr -)O,/.?D A.P. Number City 40 Zip ZZa ' qs) to 3 � -� 3 8 i Legal Description .l �I'D� Contractor 8 � IME s Project Description Addres 7 - q -a e11sa,J s -T 3 City Zip Tel. __Pdf o tzo i) (03 s1-�o3$i State Lic. City Sq. Ft. No. No. Dw. & Classif. Lic. # Size Stories Units Arch., Engr., New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Designer Address Tel. lilt /_IP Jtatu Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) Of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than rive hundred dollars (S500). O1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION. I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not em any person In any manner so as to become subject to Workers' Compensation laws of California. Date Owner NOTICE TO APPLICANT..- If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT Estimated Valuation PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical S.M.I. Grading Driveway Enc. Infrastructure TOTAL INFORMATION NAME: PHONE: AMOUNT Sao • 0Z) ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Validated by: — Validation: YELLOW = APPLICANT Date Permit PINK = FINANCE Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT , LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: I COMMAND.AMOUNT: DATE: RECEIPT: - CHECK #: INITIALS CERTIFICATE OF COMPLIANCE California Education Code 17620) Project Name: cDonald (The Hideaway) Date: January 21, 2015 Owner's Name: Phone No. 5l LP 3y- o3w/ Project Address: 80-110 Via Capri, La Quinta, CA 92253 Project Description: APN: 777-100-065 Family Dwelling Unit Tract #: Lot #'s: Type of Development: Residential iIXXI Commercial Industrial Total Square Feet of Building Area: 6,613 Sq. Ft. Certification of Applicant/Owners: The person signing certifies t e aFehal information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to t f of the owner/developer. Dated: / Z/ _ l� Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 6,613 Sq. Ft. Amount per Sq.Ft. $ 3.36 Amount Collected $ 22,219.68 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Leticia Torres, Facilities Analyst Signatur�: Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires tha this I'strict provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 9 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/Inydocs/de\•Iees/certilicate ul'compliance form updated 3-2007 11/2010 Ar I Recording Requested By First American Title NHS 144-.11kHFP�`t ` U� ? f=i-)- ) I Robert W. McDonald III 2110—A Boca Raton Dr. #20.6 Austin, Texas 78747 AVN: 777-100-065-5 TRA: 020=160 DOC # 2007-0450314 07/11/2007 08:00A Fee:10.00 .Page 1 of .2 Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk 8 Recorder I (VIII IIIIIII III.III _ II IIII 1111111 111111 III VIII IIII IIII S R U PAGE -SIZE DA MISC LONG RFD COPY M A L 465 426 CO NCOR SMFNCHG EXAM T: CTY UNI V tihaCc \bore this line' is for IYiC n'ders (.!se. TI K` UN t);?!(S;C;NI:P) GRAN't�R(S) 1: I:C•LARh:(S). tJOCUMI-ATARY't`A\ IS S none tv o "pot sw)iIr, _ (innilxilcd 011 R111 slue ur twolicrt!' conveyed, or _ (:otiiIMVc l .,n bill \;duc I ss liin anel cnci"nhrancds rc•mainin!s :n 611w of sale. t Unincorporncd arca __ Cit!- of La O.p? 1,-4 GRANT DEED f'or valuable coils ider111IJ0n, receipI- of which is herebNr acknowledged, L:SLIE P. MCDONALD hercby GR N':['(S) to ROBERT W. NICDONALD III the real propeny sitbated in the ( Curry of.Rivcrside, State of Califori .ia; more partaculad), ilCscribed as 17611>��s: All of"Grantor's itit:erest in.and to: .PARCEL 1: I.vf 38/39 (the "Lot") of .Arnended 7'racf iNo. 29894-2, as Shciwrl on SUbdivision Map the "Map") recorded on T.3cceniber 121 2002 in 13ook 327, Pages 56 to 88,.inclusive, of [flaps; in the office of IIIc Riverside County Recorder of. Said country and shown on Grant Deed recorded as Instrument No. 2003.26092: of Official Recoals. Grant .0cced reflects 1Pare I NI:crger.No- 2003 `113, as approved by the cit), of La C)Uulla. PARCEL 2: Non-cxdusivi (ascnu:nt for :access, ingress, cgreSs, drainage, rnaintcnancc, repairs aild For. Tither purposes, all as described in (i) the Amended and Restated Declatatiiin of Coven nrs; Conditions and Rcst.1,10,1crtls and Reservation of F"asenlents for. The Hideaway Owners .AssOciation (as amended or supplemented, the "Declarat.ion"), recorded on Dccember 13,. 2002, as lnsrrument No. 2002-745939 of Official Records of 16,crside Cor. niy, California; and (i.i) "F'hc Supplementary Declaration of tincxation of Property rccord6d on (March 21, 2003, as lstrurnent No. ?0037201647 of Official Records of_Rivcrside County; Cali foruia. r7CEIVED I)aICd: )uric r U ?007. Le re P. *McDonald NOV 212014 CITY OF to QUINTA COMMUNITY DEVELOPMENT SI'Al' S.S. C DUIN]"N' W. FRAVIS- 10- 2'�s �Ie eve -2,007, bef Ine m orem sunhily appeired per, LESLIE P. MCDONALD,lj.cts'oi,411.kii(j,wiI to ffie. (6r'- proved to n!c;*o6-.the b4si of sacisfact' r evidence) to be .0 S o.y I whose ii/ ice- to the within iiistrurnertr stud ickno,\xleciged.i:(:).,ti.ic.tI.i,,it he/shc/ti.le\ sccirrcd the sine; in his/her./ti-icir.authof zed and chat :b? -L menu. on die ins.tpl d-w-porson(I acted, executed. the instrOmbir. )�.or Ihe ctluuv wrl"N h -SS inv hAnd,*,and 4fidal seal. M6irin D. ReeVey Notary P6blic State of Texas My Commissibn Expires AUGUST 13, 2009 2 777620.0 CITY OF LA QUINTA -.PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. , Date: / % � /J Ju Developer: [ (�/J/a LZ G1� ` J 10 FS Tract No.: Z % 99 7 ZTract Name: Lot No. (s): A 13 Address(s): G.j' - % -D LA L' �2 ( Phone Number: (�) The following are the requirements for Public Works Clearance to authorize issuance --from the R�Ctiv�D Building & Safety Department: ❑ CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW ❑ TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW AUG 12 2014 ❑ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1, #2, #3, #5 & #7 BELOW ❑ WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW CITY OF LA QUINTA COMMUNITY DEVELOPMENT 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. 2. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. 3. Attach recorded final map or title information/grant deed showing proposed building locations.are legal lots. 4. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. 5. Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. 6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. 7. Complete and sign the attached water -quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: http://www.la-guinta.org/PlanCheck/m search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. Recommended by: Date: Public Works Distribution: ( (/) Green Sheet to Building & Safety ( ) Green Sheet to Planning Department Declined for approval for reason(s) as follow(s), please correct and resubmit: , TAChecklists - Forms & Applications\Forms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 10-02-12.doc 1 City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM10 Aareement (< 1 acre/lot or Infill Proiect) Project Information Project Contractor: Project Phase (check one) Construction .0 Demolition Project Name: � { 1100 L-0' U`"rS I cte'J LE qr� Project Tract/Lot Numbers: l 9 �' Z �� .3g 3 „ _ 1 0 Project Street Address: _��l V Total Acres in Active Construction (< 1 ae per Lot): J9r l 2(O 9 r" Anticipated Start Date: 3_1A_/_f4 Anticipated Completion Date: 4-/ 1�l PM10 Contact Information Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed _ below is responsible for dust control during business and non -business hours. Name: A -0(5j S T 1 , Title: P41 3rc Y " 1 ' Company Name: Ari AUT �C►MIL S Mailing Address: .� 1��0^+ �-D City, State, ZIP Code: (Nw � 7710 Primary Phone #: s i Fax #: —7 W) 24 Hour Emergency Phone#: ` Cell Phone #: • f I ,, r' Email Address: G S T- co to deJ(-1oo1oF,,j7-_ 0- f PM10 Certificate #: V .J " ` 9' j_00 The above stated property owner (or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; - ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. Acknowledges that dust control is required twenty-four _ (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and. all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; Shall authorize representatives of City/County to enter the property .for inspection and/or abatement purposes; ❖ Shall hold Slessthe County and its representatives from•liability for any actions related to this dust control platy initiated abatement activities. Signature or Authorized Representative Date CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD OFFIC*t Ccf%f CF1R-PRF-01 Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Page 1 of 14 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml GENERAL INFORMATION 01 Project Name McDonald Residence 02 Calculation Description Title 24 Analysis 03 This building incorporates one or more SpeclaI Feature§'shown below. '. «i 03 Project Location 80110 Via Capri 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 135 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FTZ) 6613 15 Number of Zones 6 16 Slab Area (FTZ) 5529 17 Number of Stories 2 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (FTZ) N/A'` 21 Glazing Percentage (%) 22.5% COMPLIANCE RESULTS 01 Building Complies with`Computer Performance" 02 This building incorporates atu�res that�equlre fiend testing and/oar, �e tlfication�by a cenified�HERS�rai�;t/undenthe supervision of a CEC-approved HERS provider. 03 This building incorporates one or more SpeclaI Feature§'shown below. '. «i ENERGY USE SUMMARY 04 "' } 05 06 07 08 Energy Use Standard (kTDV/ft) Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.14 3.52 -0.38 -12.1% Space Cooling 115.68 107.74 7.94 6.9% IAQ Ventilation 1.41 1.41 _ 0.0% Water Heating 4.10 3.97 CITY OF LA UU11N I A 1 3.2% Photovoltaic Offset ----0.00 1ILDIJG & SAFbi D �' 1. Compliance Energy Total 124.33 116.64 P rn 07,69 6.2% L ONSTFiUU I IUIN ATE /LBY Registration Number: 214-N0097593B-000000000-0000 Registration Date/Time: 2014-11-19 10:38:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance' Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian=14.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Window overhangs and/or fins CF1 R -PRF -01 Page 2 of 14 HERS FEATURE SUMMARY _ The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: - • Minimum Airflow • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Verified low -leakage ducts located entirely in conditioned. space Domestic Hot Water System Verifications: ■+ None v;'a;: �E� .t sa r' _,W Jr r rtr 4 i__ ► � i c ENERGY DESIGN RATING /!+ 'jj /j )% A jj '' ' tt ` . �F�� � �4:.�-..«.���� .�i. 't.. j:�'.''i',1�.ik o . This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach_fof the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and component§'not'�r'-egulated by Title 24, -Part 6 (sucn'as dorimestio appliances and'consdmer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating-.� MarginPercent Improvement Total Energy (kTDV/f2)• `.. 7 159.63 ''. .151.94 .. 7.69 4.8% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION ; " 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water . Heating Systems McDonald Residence 6613 1 18 6 0 2 Registration Numbe1r: 214-N0097593B-000000000-0000 Registration Date/Time: 2014-11-19 10:36:21 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: CaICERTS inc. Report Generated at: 2014-11-19 10:24:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Page 3 of 14 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-1.4.xml ZONE INFORMATION 01 02 03 04 05 06 t 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Master Conditioned HVAC Master1 1003 15.8 DHW Sys 1 Great Sitting Room Conditioned HVAC great sitting2 1717 16.3 DHW Sys 1 Snug and Dining Room Conditioned HVAC snug dining3 882 16.3 DHW Sys 1 Kitchen Breakfast and Med Conditioned HVAC kitchen media4 1511 16.3 DHW Sys 1 Guest Conditioned HVAC guest5 416 14 DHW Sys 1 ' 2nd Floor Conditioned HVAC 2nd6 1084 16.3 DHW Sys 1 Registration'Number: 214-N009759313-000000000-0000 Registration Date/Time: 2014-11-19 10:38:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CFI R -PRF -01 Page 4 of 14 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation' Gross Area (ft2) Window Area (ft2) Tilt(deg) 10d Wall Master R-21 Wall (W.21.2x6.16) 10 specify - 438 18 90 100d Wall Master R-21 Wall (W.21.2x6.16) 100 specify - 284 16 90 190d Wall Master R-21 Wall (W.21.2x6.16) 190 - specify - . 802 125.2 90 280d Wall Master R-21 Wall (W.21.2x6.16) 280 - specify - 784 117.4 90 _ . Roof _ Master R-38 Roof(R.38.2x14.16) 1003 NE Wall Great Sifting Room R-21 Wali (W.21.2x6.16) 45 Right 80 0 90 SE Wall Great Sifting Room R-21 Wali (W.21.2x6.16) 135 Front 482 152.5 90 SW Wall Great Sitting Room R-21 Wall (W.21.2x6.16) 225 Left 290 0 90 NW Wail Great Sifting Room R-21 Wall (W.21.2x6.16) 315 Back 976 275 90 Roof 2 Great Sitting Room R-38 Roof(R.38.2x14.16) 1717 SE Wall 2 Snug and Dining Room R-21 Wali (W.21.2x6.16) 135 Front 224 72 90 SW Wall 2 Snug`and Dining Roomr"" , <R-21Wa11 (W:21*2x6:16]-,225 .. « Left 112 0 90 NW Wall 2 Snug and Dining Room ''. _�_... v ,pR-2 Wall (W.212x6 16) .:' h"' 315 - -� .. Back . 224 54 90 Roof 3 Snug and'Dlning Room R-38 Roof(R.38;2x14 16)`` ImA04 882 NE Wall 2 Kitchen Breakfast and Med' "'�R=2TWa11 (W 21.226 16) ;r ' X45,,, '-V'= Right 1120 38.3 90 SE Wall 3 Kitchen. Breakfast and Med R-21 Wall (W.21.2x6.16) 135 Front 608 43.8 90 SW -Wall 3' Kitchen Breakfast and Med R-21 Wall (W.21.2x6.16) 225 Left 304 72 90 NW Wall 3 Kitchen Breakfast and Med R-21 Wall (W.21.2x6.16) 315 Back 528 156 90 Roof 4 Kitchen Breakfast and Med R-38 Roof(R.38.2x14.16) 1511 , NE Wall 3 Guest R721 Wall (W.21.2x6.16) 45 Right 224 42.4 90 SE Wall 4 Guest R-21 Wall (W.21.2x6.16) 135 Front 308 53.6 90 SW Wall 4 Guest R-21 Wall (W.21.2x6.16) 225 Left 266' 0 90 Roof 5 Guest R-38 Roof(R.38.2x14.16) _ 416 NE Wall 4 2nd Floor R-21 Wall (W.21.2x6.16) 45 Right 350 22.8 90 SE Wall 5 2nd Floor R-21 Wall (W.21.2x6.16) 135 Front 410 11.4 90 SW Wall 5 2nd Floor R-21 Wall (W.21.2x6.16) 225 Left 192 30 90 NW Wall 4 2nd Floor R-21 Wall (W.2.1.2x6.16) 315 Back 410 188 90 Roof 6 2nd Floor R-38 Roof(R.38.2x14.16) 1084 a Registration Number: 214-1400975938-000000000-0000 Registration Date/Time: 2014-11-19 10:38:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xmi CF1 R -PRF -01 Page 5 of 14 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 4.36764 0.1 0.85 No No Registration Number: 214-N0097593B-000000000-0000 Registration Date/Time: 2014-11-19 10:38:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: McDonald Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Input File Name: McDonald Res-Cornerstone-Brian-14.xml CFI R -PRF -01 Page 6 of 14 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ftZ) U -factor SHGC Exterior Shading Window Window 10d Wall (- specify --10) ---- --- 1 18.0 0.39 0.28 Insect Screen (default) Window 2 Window 100d Wall (- specify --100) - 1 8.0 0.39 0.28 Insect Screen (default) Window 3 Window 100d Wall (- specify --100) ---- - 1 8.0 0.39 0.28 Insect Screen (default) Window 4 Window 190d Wall (- specify --190) ---- ---- 1 8.0 0.39 0.28 Insect Screen (default) Window 5 Window 190d Wall (- specify --190) ---- --- 1 21.6 0.39 0.28 Insect Screen (default) Window 6 Window 190d Wall (- specify --190) ---- - 1 16.0 0.39 0.28 Insect Screen (default) Window 7 Window 190d Wall (- specify --190) ---- - 1 16.0 0.39 0.28 Insect Screen (default) Window 8 Window 190d.Wall (- specify --190) - - -- 1 8.0 0.39 0.28 Insect Screen (default) Window 9 Window 190d Wall (- specify --190) ---- -- 1 8.0 0.39 0.28 Insect Screen (default) Window 10 Window 190d Wall (- specify --190) ---- -- 1 21.6 0.39 0.28 Insect Screen (default) Window 11 Window 190d Wall (--specify --190)„ r. - 1 8.0 0.39 0.28 Insect Screen (default) Window 12 Window ► 190.6.Wall (-,specify -x1190) 1 18.0 0.39 0.28 Insect Screen (default) Window 13 Window 280d Wall (- specify -280)` -- '.- - v 1 3.8 0.39 0.28 Insect Screen (default) Window 14 Window 280d Wall ( specify -280) ' f --- �'=-- l ;' 1\- { 3.8 0.39 0.28 Insect Screen (default) Window 15 Window 280d Wall (- specify --280) ---- - 1 3:8 0.39 0.28 Insect Screen (default) Window 16 Window 280d Wall (- specify --280) ---- --- 1 18.0 0.39 0.28 Insect Screen (default) Window 17 Window _ 280d Wall (- specify --280) ---- --- 1 54.0 0.39 0.28 Insect Screen (default) Window 18 Window 280d Wall (=specify --280) ---- ---- 1 18.0 0.39 0.28 Insect Screen (default) Window 19 Window 280d Wall (- specify --280) - --- 1 8.0 0.39. 0.28 Insect Screen (default) Window 20 Window 280d Wall (- specify --280) ---- --- 1 8.0 0.39 0.28 Insect Screen (default) Window 21 Window SE Wall (Front -135) 4.0 10.0 1 40.0 0.39 0.28 Insect Screen (default) Window 22 Window SE Wall (Front -135) 9.0 12.5 1 112.5 0.39 0.28 Insect Screen (default) Window 23 Window NW Wall (Back -315) 8.0 8.0 1 64.0 0.39 0.28 Insect Screen (default) Window 24 Window NW Wall (Back -315) 24.0 8.0 1 192.0 0.39 0.28 Insect Screen (default) Window 25 Window NW Wall (Back -315) --- --- 1 3.8 0.39 0.28 Insect Screen (default) Window 26 Window NW Wall (Back -315) - 1 3.8 0.39 0.28 Insect Screen (default) Window 27 Window NW Wall (Back -315) ---- - 1 3.8 0.39 0.28 Insect Screen (default) Window 28 Window NW Wall (Back -315) -- -- 1 3.8 0.39 0.28 Insect Screen (default) Window 29 Window NW Wall (Back -315) ---- - 1 3.8 0.39 0.28 Insect Screen (default) Registration Number: 214-N0097593B-000000000-0000 Registration Date/Time: 2014-11-19 10:38:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance. Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: McDonald Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Input File Name: McDonald Res-Cornerstone-Brian-14.xmi CF1R-PRF-01 Page 7 of 14 Window 30 Window SE Wall 2 (Front -135) - --- 1 72.0 0.39 0.28 Insect Screen (default) .Window 31 Window NW Wall 2 (Back -315) ---- ---- 1 18.0 0.39 0.28 Insect Screen (default) Window 32 Window NW Wall 2 (Back -315) ---- --- 1 18.0 0.39 0.28 Insect Screen (default) Window 33 Window NW Wall 2 (Back -315) --- --- 1 18.0 0.39. 0.28 Insect Screen (default) Window 34 Window NE Wall 2 (Right -45) ---- --- 1 8.0 0.39- 0.28 Insect Screen (default) Window 35 Window NE Wall 2 (Right -45) --- 1 8.0 0.39 0.28 Insect Screen (default) Window 36 Window NE Wall 2 (Right45) ---- --- 1 2.3 0.39 0.28 Insect Screen (default) Window 37. Window NE Wall 2 (Right -45) ---- --- 1 20.0 0.39 0.28 Insect Screen (default) Window 38 Window SE Wall 3 (Front -135) ---- --- 1 3:8 0.39 0.28 Insect Screen (default) Window 39 Window SE Wall 3 (Front -135) --- 1 8.0 0.39 0.28 Insect Screen (default) Window 40 Window SE Wall 3 (Front -135) • - --- 1 8.0 0.39 0.28 Insect Screen (default) Window 41 Window SE Wall 3 (Front -135) ---- --- 1 8.0 0.39 0.28 Insect Screen (default) Window 42 Window SE Wall 3 (Front -135) ---- --- 1 8.0 0.39. 0.28 Insect Screen (default) ' Window 43 Window SE Wall 3 (Front -135) ---- --- 1 8.0 0.39 0.28 Insect Screen (default) Window 44 Window ,.. SW Walh3,(Left-225)x,,,, ,, ;�--. ,r 1 72.0 0.39 0.28 Insect Screen (default) Window 45 Window NW.WaII 3 (Back -3.15 1 . 96.0 0.39 0.28 Insect Screen (default) Window 46 Window NW Walla Back 315 `} ( ) 1' .i; ^e :1, 1 - 15.0 0.39 0.28 Insect Screen (default) Window 47 Window!['`NW.WaII'--�1 30.0 0.39 0.28 Insect Screen (default) Window 48 Window - NGV Wall 3 (Back -315) - --- 1 15.0 0.39 0.28 Insect Screen (default) Window 49 Window NE Wall 3 (Right -45) --- 1 42.4 0.39 0.28 Insect Screen (default) Window 50 Window t SE Wall 4 (Front -135) ---- --- 1 5.3 0.39 0.28 Insect Screen (default) Window 51 Window SE Wall 4 (Front -135) ---- --- 1 16.1 0.39. 0.28 Insect Screen (default) Window 52 Window SE Wall 4 (Front -135) --- 1 16.1 0.39 0.28 Insect Screen (default) Window 53 Window SE Wall 4 (Front -135) --- --- 1 16.1 0.39 0.28 Insect Screen (default) Window 54 Window NE Wall 4 (Right -45) ---- --- 1 3.8 0.39 0.28 Insect Screen (default) Window 55 Window NE Wall 4 (Right -45) ---- --- 1 3.8 0.39 0.28 Insect Screen (default) Window 56 Window NE Wall 4 (Right -45) --- 1 3.8 0.39 0.28 Insect Screen (default) Window 57 Window NE Wall 4 (Right -45) ---- --- 1 3.8 0.39 0.28 Insect Screen (default) Window 58 Window NE Wall 4 (Right -45) ---- --- 1 3.8 0.39 0.28 Insect Screen (default) Window 59 Window NE Wall 4 (Right -45) ---- --- 1 3.8 0.39 0.28 Insect Screen- (default) Window 60 Window SE Wall 5 (Front -135) ---- --- 1 3.8 0.39' 0.28 Insect Screen (default) Window 61 Window SE Wall 5 (Front -135) --- 1 3.8 0.39 0.28 Insect Screen (default) Window 62 Window SE Wall 5 (Front -135) ---- --- 1 3.8 0.39 0.28 Insect Screen (default) Registration Number: 214-N0097593B-000000000-0000 Registration Date/Time: 2014-11-19 10:38:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19'10:24:32 v CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CF1 R -PRF -01 Page 8 of 14 Window 63 Window SW Wall 5 (Left -225) - 1 15.0 0.39 0.28 Insect Screen (default) Window 64 Window SW Wall 5 (Left -225) ---- - - 1 15.0 0.39 0.28 Insect Screen (default) Window 65 Window NW Wall 4 (Back -315) ---- --- 1 15.0 0.39. 0.28 Insect Screen (default) - Window 66 Window NW Wall 4 (Back -315) --- --- 1 15.0 0.39 0.28 Insect Screen (default) Window 67 Window NW Wall 4 (Back -315) ---- --- 1 15.0 0.39 0.28 Insect Screen (default) Window 68 Window NW Wall 4 (Back -315) ---- --- 1 15.0 0.39 0.28 Insect Screen (default) Window 69 Window NW Wall 4 (Back -315) ---- --- 1 15.0 0.39 0.28 Insect Screen (default) Window 70 Window NW Wall 4 (Back -315) ---- --- 1 63.0 0.39 0.28 Insect Screen (default) Window 71 Window NW Wall 4 (Back -315) ---- --- 1 12.5 0.39 0.28 Insect Screen (default) Window 72 Window NW Wall 4 (Back -315) ---- --- 1 25.0 0.39 0.28 Insect Screen (default) Window 73 Window NW Wall 4 (Back -315) - --- 1 12.5 0.39 0.28 Insect Screen (default) DOORS 01 03 .1'1 04 OS 06 07 08 09 10 11 12 13 14 01 4 ,. 02 03 04 Name ) :... �r Side of Building Area (ft2) U -factor Door t4; iSE Walli3 t' ,sr' 21.6 0.50 Door 2,r'SSE Wall 3 24.0 0.50, % .i -If ke! tF��,'d_s:l* IfaJ 4* < .�!� f". .1: i Jf 'A,". IValCii)f If - OVERHANGS AND FINS 01 03 .1'1 04 OS 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth 1 Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DIstL Bot Up Depth Top Up Dist R Bot Up Window 21 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 22 10 0.1 10 10 0 0 0' 0 0 0 0 0 0 Window 23 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 24 10 1 0.1 10 10 0 0 0 1 0 0 0 1 0 0 1 0 Registration Number: 214-N0097593B-000000000-0000 Registration Date/Time: 2014-11-19 10:38:21 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-10172014-651 HERS Provider: CaICERTS inc. Report Generated at: 2014-11-19 10:24:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov"19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xm1 CF1 R -PRF -01 Page 9 of 14 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R -value Assembly Layers 07 Name Zone 2x4 Top Chord of Perimeter (ft) Edge Insul. R -value& Depth Cavity/ Frame: no insul. / 2x4 Top Chrd Heated Covered Slab Master * = �. 355 f32 Roof Truss @ 24 in. 0.8 Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofing: Light Roof (Asphalt Shingle) Covered Slab 2 Great;Sittii-- Room .. k f . g . ' 435 :' .. - s i �t i. _'28 h _ ar•-�kwS s"•• sit None • Inside Finish: Gypsum Board No Hard surface Slab 2 'a, Great Sltting "Room, ;%'1282 -y R• x., 28>` • Cavity / Frame: R-9.1 / 2x4 R-38 Roof(R.38.2xl4.16) Ceilings (below attic) . Wood Framed Ceiling 2x4 @ 16 in. O.C. R38 Over Floor Joists: R-28.9 insul. . None 0.8 No. Hard surface Slab 3 Snug and Dining Room • Inside Finish: Gypsum Board 26 None 0.8 No Covered Slali 4 • Cavity/ Frame: R-21 / 2x6 R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 Exterior Finish: Wood Siding/sheathing/decking SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated Covered Slab Master * = �. 355 f32 None 0.8 No Hard surface Slab' / .'fir ; ` Master '" i'rR.Y-: 648 .bJ ?. °rt= 72r r - None 0.8 No Covered Slab 2 Great;Sittii-- Room .. k f . g . ' 435 :' .. - s i �t i. _'28 h _ ar•-�kwS s"•• sit None 0.8 No Hard surface Slab 2 'a, Great Sltting "Room, ;%'1282 -y R• x., 28>` None 0.8 No Covered Slab 3 Snug and Dining Room ` '" 126 10 None 0.8 No. Hard surface Slab 3 Snug and Dining Room 756 26 None 0.8 No Covered Slali 4 Kitchen Breakfast and Med 585 150 None 0.8 No Hard surface Slab 4 Kitchen Breakfast and Med 926 10 None 0.8 No Covered Slab 5 Guest 312 56 None 0.8 No Hard surface Slab 5 Guest 104 0.1 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required --- Registration Number: 214-N00975938-000000000-0000 Registration DateMme: 2014-11-19 10:38:21 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-6S1 HERS Provider: CaICERTS inc. Report Generated at: 2014-11-19 10:24:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: McDonald Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Input File Name: McDonald Res-Cornerstone-Brian-14.xml CF1 R -PRF -01 Page 10 of 14 WATER HEATING SYSTEMS 01 02 03 04 05 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 1 .0% DHW Sys 1 DHW Standard DHW Heater 1 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Large Storage 75 0.8 85000-Btu/hr 0 0.0085 DHW Heater 1 Natural Gas Large Storage 75 0.8 85000-Btu/hr 0 0.0085 WATER HEATING - HERS VERIFICATION 01 X02;,, 03 7 art 04„� 05 06 07 Heating System /Compact Distribution Recirculation Central DHW Name Pipe IInsulat on rf Parallel Piping-. Distribution Point -of Use Control Distribution DHW Sys 1 - 1/1 i�l N/A ri'r y .. /�,. ;N/A° ... : `IF : N/A i JA �r js N/A N/A N/A DHW Sys 1 - 1/2 N/A - . N/A N/A N/A N/A N/A HVAC SYSTEMS 01 02 03 _ 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC Masterl Heat Pump Heat Pump System 1 Yes Heat Pump System 1 Yes Air Distribution System 1 1003 HVAC great sitting2 Heat Pump Heat Pump System 2 Yes Heat Pump System 2 Yes Air Distribution System 2 1717 HVAC snug dining3 Heat Pump Heat Pump System 3 Yes Heat Pump System 3 Yes Air Distribution System 3 882 HVAC kitchen media4 Heat Pump Heat Pump System 4 Yes Heat Pump System 4 Yes Air Distribution System 4 1511 HVAC guest5 Heat Pump Heat Pump System 5 Yes Heat Pump System 5 Yes Air Distribution System 5 416 HVAC 2nd6 Heat Pump Heat Pump System 6 Yes Heat Pump System 6 Yes Air Distribution System 6 1084 Registration Number: 214-N0097593B-000000000-0000 Registration Date/Time: 2014-11-19 10:38:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CF1 R -PRF -01 Page 11 of 14 HVAC - HEATING SYSTEMS: Heat Pumps 01 02 03 04 05 06 07 08 09 10 03 : r r /. Heating Cooling Zonally Muitispeed HERS Name Type HSPF/COP Cap 47 Cap 17 SEER EER Controlled Compressor Verification Heat Pump System•1 SplitHeatPump 8.7 HSPF 46500 46500 15 12.5 No No Heat Pump System Required Verified HVAC kitchen media4 SCSysRpt 1 350 Not Required Required Verified 1 -hers -cool Heat Pump System 2 SplitHeatPump 8.5 HSPF 57000 57000 15 12.5 No No Heat Pump System Verified 1 -hers -cool Heat Pump System 3 SplitHeatPump 8.7 HSPF 35200 35200 15 12.5 No No Heat Pump System 1 -hers -cool Heat Pump System 4 SplitHeatPump 8.5 HSPF 57000 57000 15 12.5 No No Heat Pump System 1 -hers -cool Heat Pump System 5 SplitHeatPump 8.7 HSPF 35200 35200 15 12.5 No No Heat Pump System 1 -hers -cool Heat Pump System 6 SplitHeatPump 8.7 HSPF 46500 46500 15 12.5 No No Heat Pump System 1 -hers -cool HVAC HEAT PUMP.COOLING - HERS VERIFICATION 01 , %� `'. i f. ` 02 k ..� 03 : r r /. 04 05 Name" "'• :' Verified Airflow _ , h"` __Verified EER, Verified SEER Verified Refrigerant Charge HVAC Master1 SCSysRpt 1 .,^� �` 350 Not Required Required Verified HVAC great sitting2 SCSysRpt 1 ; 350 Not Required Required Verified HVAC snug dining3 SCSysRpt 1 350 Not Required Required Verified HVAC kitchen media4 SCSysRpt 1 350 Not Required Required Verified HVAC guest5 SCSysRpt 1 350 Not Required Required Verified HVAC 2nd6 SCSysRpt 1 350 Not Required Required Verified Registration Number: 214-N0097593B-000000000-0000 Registration Date/Time: 2014-11-19 10:38:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - &IR -10172014-651 Report Generated at: 2014-11-19 10:24:32 -CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CF1 R -PRF -01 Page 12 of 14 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 1 `" i9 :IIA , A Y _.� r Supply Duct Duct Leakage'% -"✓V 01�' Name Type Duct Leakage Insulation R -value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located entirely in Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution s conditioned space Required" Not Required Not Required 1 -hers -dist System 1 -hers -dist Air Distribution System 2 Ducts located entirely in Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution Required conditioned space Not Required 2 -hers -dist System 2 -hers -dist Air Distribution System 3 Ducts located entirely in Sealed and tested ` 8 Conditioned Zone Conditioned Zone None Air Distribution _ conditioned space 3 -hers -dist - - _ System 3 -hers -dist Air Distribution System 4 Ducts located entirely in Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution 4 -hers -dist conditioned space - System 4 -hers -dist Air Distribution System 5 Ducts located entirely in Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution conditioned space Air Distribution System Required System 5 -hers -dist Air Distribution System 6 Ducts located entirely in+. Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution conditioned space System 6 -hers -dist • �Me. r !.+w�..,rw.wrti'.-»e+.!r. xf..w.-�+-..�r! wP"�l.e HVAC DISTRIBUTION - HERS VERIFICATION 01 yyk �r,.wJ'# 02 1 „ "' j_A_1 z "p" 04p :: 05 06 07 1 `" i9 :IIA , A Y _.� r Duct Leakage'% -"✓V 01�' -9 Verified Duct Design Low -leakage 9 +a. Y.t ...nw ', .3si.. "'max :a:r�l.,> " ,.-•-. '�� Name Verification Duct Leakage Target (%) Verified Duct Location Return Supply Air Handier Air Distribution SystemTRequired. s 6.0 Required" Not Required Not Required 1 -hers -dist 'i Air Distribution System Required '. 6.0 Required Not Required Not Required 2 -hers -dist Air. Distribution System Required 6.0 Required Not Required Not Required - - 3 -hers -dist Air Distribution System Required 6.0 Required Not Required Not Required . 4 -hers -dist - Air Distribution System Required 6.0 Required Not Required Not Required --- 5-hers-dist Air Distribution System Required 6.0 Required Not Required Not Required 6 -hers -dist Registration Number: 214-N0097593B-000000000-0000 Registration Date/Time: 2014-11-19 10:38:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:32 -CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Page 13 of 14 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml HVAC -FAN SYSTEMS 01 02 t- 01 01 02 03 04 Name Type Fan Power (Watts/CFM)' HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 -hers -fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3 -hers -fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58• HVAC Fan 4 -hers -fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan 5 -hers -fan HVAC Fan 6 Single Speed PSC Furnace Fan 0.58 HVAC Fan 6 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 t- 01 02 03 Name _N; • . VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan _`;, Required 0.58 HVAC Fan 2 -hers -fan ix. T Required _ - ' 0.58 HVAC Fan 3-hers-fari` f;�t; �€' � w F` p: �f J 'zR6; uired` '- *t II n# 0.58 HVAC Fan 4 -hers fan g- d rJ x}3 / ?KV `Required [±w - 0.58 .€ ✓ HVAC Fan 5 -hers fan='; ;w, �^ Required• � ,ArL,A 0.58 HVAC Fan 6-hers-fan"7' , .'."'- '"'Required �'`••• 0.58 IAQ (Indoor Air Quality) FANS = �w 01 02 t- 03 t 04 05 06 Name. IAQ CFM IAQ WattsICFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification DwellingUnit 208.63 0.25 Default 0 . Required Registration Number: 214-N0097593B-000000000-0000 Registration Date/Time: 2014-11-19 10:38:21 CA Building Energy Efficiency Standards - 2013 Residential ComplianceReport Version - CF1R-10172014-651 HERS Provider: CaICERTS inc. Report Generated at: 2014-11-19 10:24:32 • • • CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CF1 R -PRF -01 Page 14 of 14 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2014-11-1910:38:21 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: • Phone: Palm Desert, CA 92211 (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify thafthe energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.' 3. The building design features or system design features identified.on-this Certificate of...Compliance.are.consistent.with the information provided on other applicable compliance documents, worksheets, calculations, plans and°specifications submitted -,to the enforcementagency forapproval wdh this building permit application. Responsible Designer Name: ` ;,^ AD Responsible Designer Signature:'..,- Tim Scott Company: �, . "' ";_ -r:,. Date Signed: 'Scott Design and Title 24, Incy ., 2014-11-19 10:38:21 - - Address: License: 77085 Michigan Drive 'k na City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 C1 i Y OF LA CSU I'"TA - BUILDH Ju & SAFE DEPT. - IV `D FOR CONSTRUCTION Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document n din ?o=way implies Regbt(ation Provider respon ibility for the accuracy of the information. Registration Number: 214-N0097593B-000000000-0000 Registration Date/Time: 2014-11-19 10:38:21 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:32 0 BUILDING ENERGY ANALYSIS REPORT PROJECT: McDonald Residence 80110 Via Capri La Quinta, CA.92253 Project Designer: Cornerstone Architects 700 Bee Cave Road STE 200 Austin, TX 78746 (512) 329-0007 .Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm_ Desert, CA 9221.1 (760) 200-4780 Job Number: Date: 11/19/2014 CITY OF BUILDING & 8A � IQUIE P� APPROVED T. FOR CONSTRUCTION DATE,BY -X- The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. EnergyPro 6.3 by EnergySoft User Number: 6712 ID: "r ►+ ;. ., - • - .. R. CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE NOOD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CF1*F-01 Page 1 of 14 GENERAL INFORMATION 01 . Project Name McDonald Residence 02 Calculation Description Title 24 Analysis 03 This building incorporates one or more Special Features showri�below. 03 Project Location 80110 Via Capri 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07. Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 135 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FTZ) 6613 15 A� Number of Zones 6 16 Slab Area (FTZ) 5529 17 Number of Stories 2 18 Addition Cond. Floor Area N/A X1+91, Natural Gas Available Yes 20 Addition Slab Area (FTZ) N/A RC2 Glazing Percentage (%) 22.5% A'W COMPLIANCE RESULTS $� v 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features showri�below. ENERGY USE SUMMARY 04 05�e`r 06 07 08 Energy Use (kTDVlft) Standard ,Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.14 3.52 -0.38 -12.1% Space Cooling 115.68 107.74 7.94 6.9% IAQ Ventilation 1.41 1.41 0.00 0.0% Water Heating I4A 4.10 3.97 0.13 3.2% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 124.33 116.64 7.69 6.2% Registration Number: 0� Registration Date/Time: HERS Provider: CA Building Energy Efficiency StanUa ds - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:21 CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Window overhangs and/or fins CF*F-01 Page 2of14 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Verified low -leakage ducts located entirely in conditioned space Domestic Hot Water System Verifications: — None —I ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components include' in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part %(;such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy systema Reference Energy<Use Energy.Design Rating Margin Percent Improvement Total Energy (kTDVH2)• 159.631 151.94 7.69 4.8% includes calculated Appliances and Miscellaneous Energy Use (AMEU)' IQ BUILDING . FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor A%(sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water. Heating Systems McDonald Residence 6613 1 18 6 0 2 .O00 'e Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:21 CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE h*OD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CFOF-01 Page 3 of 14 ZONE INFORMATION 01 02 03 04 65 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Master Conditioned HVAC Masterl 1003 15.8 DHW Sys 1 Great Sitting Room Conditioned HVAC great sitting2 1717 16.3 DHW Sys 1 Snug and Dining Room Conditioned HVAC snug dining3 882 16.3 DHW Sys 1 Kitchen Breakfast and Med Conditioned HVAC kitchen media4 1511 16.3 DHW Sys 1 Guest Conditioned HVAC guests 416 14 DHW Sys 1 2nd Floor Conditioned HVAC 2nd6 1 16.3 DHW Sys 1 e ®dVI 4 e e V� .e C� Registration Number: �® Registration Date/Time: CA Building Energy Efficiency Stands - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-11-19 10:24:21 CERTIFOF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE rfOD Project Name: McDonald Residence Ca culation Daie/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CF*F-01 Page 4 of 14 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (W) Tilt(deg) 10d Wall Master R-21 Wall (W.21.2x6.16) 10 - specify - 438 18 90 100d Wall Master R-21 Wall (W21.2x6.16) 100 - specify - 284 16 90 190d Wall Master R-21 Wall (W.21.2x6.16) 190 - specify - 802 125.2 90 280d Wall Master R-21 Wall (W.21.2x6.16) 280 - specify - 784 117.4 90 Roof Master R-38 Roof(R.38.2x14.16) 1003 NE Wall Great Sitting Room R-21 Wall (W21.2x6.16) b 45 Right 80 0 90 SE Wall Great Sifting Room R-21 Wall (W.21.2x6.16) 4� 135 Front 482 152.5 90 SW Wall Great Sifting Room R-21 Wall.(W.21.2x6.16) M� 225 Left 290 0 90 NW Wall Great Sifting Room R-21 Wall (W21.2x6.16)�` 315 Back 976 275 90 Roof 2 Great Sifting Room R-38 Roof(R.38.2x14.;16-1* 1717 SE Wall 2 Snug and Dining Room R-21 Wall (W.21.2xx6�16) 135 Front 224 72 90 SW Wall 2 Snug and Dining Room R-21 Wall (W.2 zi x6.16) 225 Left 112 0 90 NW Wall 2 Snug and Dining Room R-21 Wall (t21?24.16) 315 Back 224 54 90 Roof 3 Snug and Dining Room R-38 Roo ,f(R`38.2x14.16) 882 NE Wall 2 Kitchen Breakfast and Med R-21 M71r(W.21.2x6.16) 45 Right 1120 38.3 90 SE Wall 3 Kitchen Breakfast and Med R-31�Wall (W.21.2x6.16) 135 Front 608 43.8 90 SW Wall 3 Kitchen Breakfast and Med �RlfWall (W21.2x6.16) 225 Left 304 72 90 NW Wall 3 Kitchen Breakfast and Med �:16-21 Wall (W.21.2x6.16) 315 Back 528 156 90 Roof 4 Kitchen Breakfast and Med R-38 Roof(R.38.2x14.16) 1511 NE Wall 3 Guest R-21 Wall (W21.2x6.16) 45 Right 224 42.4 90 SE Wall 4 Guest ., �v R-21 Wall (W21.2x6.16) 135 Front 308 53.6 90 SW Wall 4 Roof 5 Guest A *% Guest '1 R-21 Wall (W21.2x6.16) R-38 Roof(R.38.2x14.16) 225 Left 266 416 0 90 NE Wall 4 2nd Floo�� _ R-21 Wall (W.21.2x6.16) 45 Right 350 22.8 90 SE Wall 5 2nd Floor R-21 Wall (W21.2x6.16) 135 Front 410 11.4 90 SW Wall 5 2ndwFJoor R-21 Wall (W21.2x6.16) 225 Left 192 30 90 NW Wall �P2nd"'FIoor R-21 Wall (W.21.2x6.16) 315 Back 410 188 90 Roof 6 P2nd Floor R-38 Roof(R.38.2x14.16) 1084 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:21 CERTIF&_ OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: McDonald -Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis . Input File Name: McDonald Res-Cornerstone-Brian-14.xmi CFOF-01 Page 5 of 14 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 4:36764 0.1 0.85 No No �0 • V� �0 4& Registration Registration Number:��t�O Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-11-19 10:24:21 0 CERTIFW OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CF*F-01 Page 6 of 14 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height Width(ft) (ft) Multiplier Area (W) U -factor SHGC Exterior Shading Window Window 10d Wall (- specify -10) - - 1 18.0 0.39 0.28 Insect Screen (default) Window 2 Window 100d Wall (- specify -100) - - 1 8.0 0.39 0.28 Insect Screen (default) Window 3 Window 100d Wall (- specify -100) - - 1 8.0 0.39 0.28 Insect Screen (default) Window 4 Window 190d Wall (- specify -190) - - 1 8.0 0.39 0.28 Insect Screen (default) Window 5 Window 190d Wall (- specify -190) - e, -- 1 21.6 0.39 0.28 Insect Screen (default) Window 6 Window 190d Wall (- specify --190) - - 1 16.0 0.39 0.28 Insect Screen (default) Window 7 Window 190d Wall (- specify -190),` -- 1 16.0 0.39 0.28 Insect Screen (default) Window 8 Window 190d Wall (- specify -190) - 1 8.0 0.39 0.28 Insect Screen (default) Window 9 Window 190d Wall (- specify -190)0`- - 1 8.0 0.39 0.28 Insect Screen (default) Window 10 Window 190d Wall (- specify -190) my - - 1 21.6 0.39 0.28 Insect Screen (default) Window 11 Window 190d Wall (- specify -190) w - -- 1 8.0 0.39 0.28 Insect Screen (default) Window 12 Window 190d Wall (- specify -190) � -- - 1 18.0 0.39 0.28 Insect Screen (default) Window 13 Window 280d Wall (- specify -280) - - 1 3.8 0.39 0.28 Insect Screen (default) Window 14 Window 280d Wall (- specify -280) �a� - -- 1 3.8 0.39 0.28 Insect Screen (default) Window 15 Window 280d Wall (- specify -280) - - 1 3.8 0.39 0.28 Insect Screen (default) Window 16 Window 280d Wall (- specify -280) - -- 1 18.0 0.39 0.28 Insect Screen (default) Window 17 Window 280d Wall (- specify---'��280) - - 1 54.0 0.39 0.28 Insect Screen (default) Window 18 Window 280d Wall (- spe„c fyy -280) - - 1 18.0 0.39 0.28 Insect Screen (default) Window 19 Window 280d Wall (- specify -280) - - 1 8.0 0.39 0.28 Insect Screen (default) Window 20 Window 2 8 0 d Wal�(specify --280) -- - 1 8.0 0.39 0.28 Insect Screen (default) Window 21 Window SECWaII(Front-135) 4.0 10.0 1 40.0 0.39 0.28 Insect Screen (default) Window 22 Window SE.Wall (Front -135) 9.0 12.5 1 112.5 0.39 0.28 Insect Screen (default) Window 23 Window 1M Wall (Back -315) 8.0 8.0 1 64.0 0.39 0.28 Insect Screen (default) Window 24 Window *VNW Wall (Back -315) 24.0 8.0 1 192.0 0.39 0.28 Insect Screen (default) Window 25 Window NW Wall (Back -315) - -- 1 3.8 0.39 0.28 Insect Screen (default) Window 26 Windows NW Wall (Back -315) - -- 1 3.8 0.39 0.28 Insect Screen (default) Window 27 Windows NW Wall (Back -315) - - 1 3.8 0.39 0.28 Insect Screen (default) Window 28 Window NW Wall (Back -315) - -- 1 3.8 0.39 0.28 Insect Screen (default) Window 29 Window NW Wall (Back -315) - -- 1 3.8 0.39 0.28 Insect Screen (default) ♦ 0 Registration Number: ® Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:21 CERTIFIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CFIWF-01 Page 7 of 14 Window 30 Window SE Wall 2 (Front -135) - - 1 72.0 0.39 0.28 Insect Screen (default) Window 31 Window NW Wall 2 (Back -315) - - 1 18.0 0.39 0.28 Insect Screen (default) window 32 Window NW Wall 2 (Back -315) - - 1 18.0 0.39 0.28 Insect Screen (default) Window 33 Window NW Wall 2 (Back -315) - - 1 18.0 0.39 0.28 Insect Screen (default) Window 34 Window NE Wall 2 (Right -45) -- 1 8.0 0.39 0.28 1 Insect Screen (default) Window 35 Window NE Wall 2 (Right -45) - - 1 8.0 0.39 0.28 Insect Screen (default) Window 36 Window NE Wall 2 (Right -45) - -- 1 2.3 0.39 0.28 Insect Screen (default) Window 37 Window NE Wall 2 (Right -45) -- - 1 20.0 0.39 0.28 Insect Screen (default) Window 38 Wndow SE Wall 3 (Front -135) - - 1 3.8 0.39 0.28 Insect Screen (default) Window 39 Window SE Wall 3 (Front -135) - ^� - 1 8.0 0.39 0.28 Insect Screen (default) Window 40 Window SE Wall 3 (Front -1 35)- 1 8.0 0.39 0.28 Insect Screen (default) Window 41 Window SE Wall 3 (Front -135) G - 1 8.0 0.39 0.28 Insect Screen (default) Window 42 Window SE Wall 3 (Front -135) -- - 1 8.0 0.39 0.28 Insect Screen (default) Window 43 Window SE Wall 3 (Front -135) �� 'r - - 1 8.0 0.39 0.28 Insect Screen (default) Window 44 Window SW Wall 3 (Left -225)` - - 1 72.0 0.39 0.28 Insect Screen (default) Wndow 45 Wndow NW Wall 3 (Back -315) Ov -- - 1 96.0 0.39 0.28 Insect Screen (default) Window 46 Window NW Wall 3 (Back -315) �` - - 1 15.0 0.39 0.28 Insect Screen (default) Window, 47 Window NW Wall 3 (Back -315) �V - - 1 30.0 0.39 0.28 Insect Screen (default) Window 48 Window NW Wall 3 (Back -315) 0 -- - 1 15.0 0.39 0.28 Insect Screen (default) Window 49 Window NE Wall 3 (Right -45Y - - 1 42.4 0.39 0.28 Insect Screen (default) Window 50 Window SE Wall 4 (Front;1A.8) - - 1 5.3 0.39 0.28 Insect Screen (default) Window 51 Window SE Wall 4 (Frb&�135) - - 1 16.1 0.39 0.28 Insect Screen (default) Window 52 Window SE Wall 4s.� (Front -135) - - 1 16.1 0.39 0.28 Insect Screen (default) Window 53 Window SE WaI .t(Front-135) - - 1 16.1 0.39 0.28 Insect Screen (default) Window 54 Window NE ,Wall 4 (Right -45) - -- 1 3.8 0.39 0.28 Insect Screen (default) Window 55 WindowNEyWall 4 (Right 45) - - 1 3.8 0.39 0.28 Insect Screen (default) Window 56 Window �.NE Wall 4 (Right -45) - - 1 3.8 0.39 0.28 Insect Screen (default) Window 57 Window %SNE Wall 4 (Right -45) - -- 1 3.8 0.39 0.28 Insect Screen (default) Window 58 Window NE Wall 4 (Right -45) -- - 1 3.8 0.39 0.28 Insect Screen (default) Window 59 Window` NE Wall 4 (Right -45) - -- 1 3.8 0.39 0.28 Insect Screen (default) Window 60 Window`s SE Wall 5 (Front -135) -- - 1 3.8 0.39 0.28 Insect Screen (default) Window 61 Window . �`" SE Wall 5 (Front -135) - -- 1 3.8 0.39 0.28 Insect Screen (default) Window 62 Window SE Wall 5 (Front -135) -- - 1 3.8 0.39 0.28 Insect Screen (default) • to Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Stand ds - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:21 CERTIF*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: McDonald Residence Ca culation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File.Name: McDonald Res-Cornerstone-Brian-14.xml CFO' F-01 Page 8of14 Window 63 Window SW Wall 5 (Left -225) - - 1 15.0 0.39 0.28 Insect Screen (default) Window 64 Window SW Wall.5 (Left -225) _ - 1 15.0 0.39 0.28 Insect Screen (default) Window 65 Window NW Wall 4 (Back -315) - - 1 15.0. 0.39 0.28 Insect Screen (default) Window 66 Window NW Wall 4 (Back -315) - - 1 15.0 0.39 0.28 Insect Screen (default) Window 67 Window NW Wall 4 (Back -315) - - 1 15.0 0.39 0.28 Insect Screen (default) Window 68 Window NW Wall 4 (Back -315) -- - 1 15.0 0.39 0.28 Insect Screen (default) Window 69 Window NW Wall 4 (Back -315) -- - 1 15.0 0.39 0.28 Insect Screen (default) Window 70 Window NW Wall 4 (Back -315) -- - 1 63.0 0.39 0.28 Insect Screen (default) Window 71 Window NW Wall 4 (Back -315) --. - 1 12.5 0.39 0.28 Insect Screen (default) Window 72 Window NW Wall 4 (Back -315) -- �� y - 1 25.0 0.39 0.28 Insect Screen (default). Window 73 Window NW Wall 4 (Back -315) -�`� - 1 12.5 1 0.39 0.28 Insect Screen (default) DOORS V . A� 01 03 04 Name Side of Building Area (ft2) U -factor Door Q SE Wall 3 21.6 0.50 Door 2 4V SE Wall 3 24.0 0.50 *A S OVERHANGS AND FINS V . A� 01 02 03 04 _CO -5 06 07 08 09 10 11 12 13 1 14 Overhang �� Left Fin Right Fin Window Depth Left Right Dist Up Extejt) Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Window 21 10 0.1 41 .* v 10 0 0 0 0 0 0 0 0 0 Window 22 10 0.1 , d10 10 0 0 0 0 0 0 0 0 0 Window 23 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 24 10 0.1 �`� 10 10 0 0 0 0 0 0 0 0 0 Registration Number: i� Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:21 CERTIFW OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IOD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CF&F-01 Page 9of14 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R -value Assembly Layers 07 Name Zone Area (ft2) 2x4 Top Chord of Perimeter (ft) Cavity/Frame: no insul. /2x4 Top Chrd Carpeted Fraction Heated Covered Slab Roof Truss @ 24 in. `'� Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofing: Light Roof (Asphalt Shingle) 72 None 0.8 No Covered Slab 2 • Inside Finish: Gypsum Board 28 None 0.8 No • Cavity/Frame: R-9.1 /2x4 R-38 Roof(R.38.2xl4.16) Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 Over Floor Joists: R-28.9 insul. Covered Slab 3 Snug and Dining Room 126 10 None • Inside Finish: Gypsum Board No Hard surface Slab 3 Snug and Dining Room �� 756 26 • Cavity/Frame: R-21 /2x6 R-21 Wall (W 21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C.�� R 21 Exterior Finish: Wood Siding/sheathing/decking ov SLAB FLOORS � w 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required 01 02 03 04 05 06 07 Name Zone Area (ft2) �i Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated Covered Slab Master 355 `'� 32 None 0.8 No Hard surface Slab Master 648v 72 None 0.8 No Covered Slab 2 Great Sitting Room 435' 28 None 0.8 No Hard surface Slab 2 Great Sitting Room "a1�282 28 None 0.8 No Covered Slab 3 Snug and Dining Room 126 10 None 0.8 No Hard surface Slab 3 Snug and Dining Room �� 756 26 None 0.8 No Covered Slab 4 Kitchen Breakfast and Med A �`� 585 150 None 0.8 No Hard surface Slab 4 Kitchen Breakfast and Med ! 926 10 None 0.8 No Covered Slab 5 Guest � 312 56 None 0.8 No Hard surface Slab 5 Guest �_ 104 0.1 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATIONv 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required .,f �► Not Required Not Required — ♦f% Registration Number: , Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards�`- 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:21 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xm1 CFOF-01 Page 10 of 14 WATER HEATING SYSTEMS 01 02 03 04 05 01 02 03 04 05 06• Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 1 .0% DHW Sys 1 DHW Standard DHW Heater 1 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) �, EEhergy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Large Storage 75 '. 0.8 85000-Btu/hr 0 0.0085 DHW Heater 1 Natural Gas Large Storage 75 �~ 0.8 85000-Btu/hr 0 T 0.0085 AZO WATER HEATING - HERS VERIFICATION~� • 01 02 03` 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1.- 1/1 N/A N/Ap N/A N/A N/A N/A DHW Sys 1 - 1/2 N/A Heat Pump System 1 N/A N/A N/A N/A r` HVAC SYSTEMS �w 01 02 A V 03 04 05 06 07 Heating System 4a Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC Masterl Heat Pump Heat Pump System 1 Yes Heat Pump System 1 Yes Air Distribution System 1 1003 HVAC great sitting2 Heat Pump ® Heat Pump System 2 Yes Heat Pump System 2 Yes Air Distribution System 2 1717 HVAC snug.dining3 Heat Pump �� Heat Pump System 3 Yes Heat Pump System 3 Yes AirSystemDistribution 882 HVAC kitchen media4 Heat Pump Heat Pump System 4 Yes Heat Pump System 4 Yes Air Distribution System 4 1511 HVAC guest5 �t`e Heat"Pump Heat Pump System 5 Yes Heat Pump System 5 Yes Air Distribution System 5 416 �.� HVAC 2nd6 Heat Pump w_ Heat Pump System 6 Yes Heat Pump System 6 Yes Air Distribution System 6 1084 I�y Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:21 CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IOD Project Name: McDonald Residence Ca culation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CF*F-01 Page 11 of 14 HVAC - HEATING SYSTEMS: Heat Pumps 01 02 03 04 05 06 07 08 09 10 04 05 Heating Cooling Zonally Multispeed HERS Name Type HSPF/COP Cap 47 Cap 17 SEER EER Controlled Compressor Verification Heat Pump System 1 SplitHeatPump 8.7 HSPF 46500 46500 15 12.5 No No Heat Pump System 1 -hers -cool Heat Pump System 2 SplitHeatPump 8.5 HSPF 57000 57000 15 12.5 No No Heat Pump System 1 -hers -cool Heat Pump System 3 SplitHeatPump 8.7 HSPF 35200 35200 15 12.5 No No Heat Pump System 1 -hers -cool Heat Pump System Heat Pump System 4 SplitHeatPump 8.5 HSPF 57000 570 � 15 12.5 No No 1 -hers -cool Heat Pump System Heat Pump System 5 SplitHeatPump 8.7 HSPF 35200 < 5200 15 12.5 No No 1 -hers -cool Heat Pump System 6 SplitHeatPump 8.7 HSPF �` 465007) 46500 15 12.5 No No Heat Pump System 1 -hers -cool %4► HVAC HEAT PUMP COOLING - HERS VERIFICATION 01 02 v 03 04 05 Name Verified Airflow `� Verified EER Verified SEER Verified Refrigerant Charge HVAC Masterl SCSysRpt 1 350 �. Not Required Required Verified HVAC great sitting2 SCSysRpt 1 350 Not Required Required Verified HVAC snug dining3 SCSysRpt 1 3550��7' Not Required Required Verified HVAC kitchen media4 SCSysRpt 1 350'.1 Not Required Required Verified HVAC guests SCSysRpt 1 350 Not Required Required Verified HVAC 2nd6 SCSysRpt 1 O, J 350 Not Required Required Verified VWV ®� .y Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:21 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEOD Project Name: McDonald Residence Ca culation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CF F-01 Page 2 of 14 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 *44;;� Verified Duct Design Low -leakage Supply Duct Verification Duct Leakage Target (%) Verified Duct Location Name Type Duct Leakage Insulation R -value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located entirely in Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution System 1 Air Distribution System conditioned space W 6.0 Required Not Required Not Required -- -hers -dist Air Distribution System 2 Ducts located entirely in conditioned space Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution System 2 -hers -dist Air Distribution System 3 Ducts located entirely in conditioned space Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution System 3 -hers -dist A Required 6.0 Required Air Distribution System 4 Ducts located entirely in Sealed and tested 8 Cod itioned Zone Conditioned Zone None Air Distribution conditioned space Air Distribution System Required�� � Required Not Required System 4 -hers -dist Air Distribution System 5 Ducts located entirely in Sealed and tested 8 Conditioned Zone Conditioned Zone None Air Distribution Air Distribution System conditioned space y 6.0 Required Not Required Not Required _ System 5 -hers -dist Air Distribution System 6 Ducts located entirely in conditioned space Sealed and tested 8 �A Conditioned Zone Conditioned Zone None Air Distribution System 6 -hers -dist 4t– HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 `'� 04 05 06 07 Duct Leakage *44;;� Verified Duct Design Low -leakage Name Verification Duct Leakage Target (%) Verified Duct Location Return Supply Air Handler Air Distribution System Required ,�i6.0 Required Not Required Not Required — 1 -hers -dist �► Air Distribution System Required W 6.0 Required Not Required Not Required -- 2 -hers -dist ��, Air Distribution System Required 6.0 Required Not Required Not Required — 3 -hers -dist Of Air Distribution System Required 6.0 Required Not Required Not Required — 4 -hers -dist Air Distribution System Required�� 6.0 Required Not Required Not Required -- 5 -hers -dist Air Distribution System °i Required y 6.0 Required Not Required Not Required _ 6 -hers -dist ASA eke ®y Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-11-19 10:24:21 CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I1OD . Project Name: McDonald Residence Ca culation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xml CF*F-01 - Page 13 of 14 HVAC -FAN SYSTEMS 01 02 01 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 -hers -fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3 -hers -fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4 -hers -fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan 5 -hers -fan HVAC Fan 6 Single Speed PSC Furnace Fan 0.58 HVAC Fan 6 -hers -fan Ai HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 01 02Zi 03 Name Verified Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan 6kequired 0.58 HVAC Fan 2 -hers -fan 44* Required 0.58 HVAC Fan 3 -hers -fan Qv Required 0.58 HVAC Fan 4 -hers -fan 4V Required 0.58 HVAC Fan 5 -hers -fan ��� Required 0.58 HVAC Fan 6 -hers -fan Required 0.58 rf] IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Name IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification DwellingUnit 208.63 �v 0.25 Default 0 Required . *Z0 4 O 14P V� #J1 Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-10172014-651 HERS Provider: Report Generated at: 2014-11-19 10:24:21 CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IOD Project Name: McDonald Residence Calculation Date/Time: 10:20, Wed, Nov 19, 2014 Calculation Description: Title 24 Analysis Input File Name: McDonald Res-Cornerstone-Brian-14.xm1 CF*F-01 Page 14 of 14 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Jon Scott Jon d. Scott Signature Date: Company: Scott Design and Title 24, Inc, 11/19/2014 Address: CEA/HERS Certification Identification (If applicable): 77-085 Michigan Drive City/State ip: Palm Desert, CA 92211 Phone: 11�11- (76,0) 200-4780 RESPONSIBLE PERSON'S.DECLARATION STATEMENT I certify the following under penalty of pedury, under the laws of the State of California: ,�% 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for�the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of;C-ompliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.W 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agencyfor approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Brian McLaury Company: A v Date Signed: Cornerstone Architects ^� Address: License: 700 Bee Cave Road STE 200 City/State/Zip: Phone: Austin, TX 78746 ,�� (512) 329-0007 V 0� Registration Number: ►, Registration Date/Time: HERS Provider: CA Building Energy Efficiency Stanch ds - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-11-19 10:24:21 r 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 WAR R Project Name Date McDonald Residence 11111912014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form.with plans. Building Envelope Measures: 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50.0 a : Minimum R-30 R-19 for Alterations insulation in wood -frame ceiling orequivalent U -factor. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50.0 c : Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor. *§1 50.0 d : Minimum R-19 insulation in raised wood -frame floor orequivalent U -factor. 150.0 : Air retarding wrap is tested, labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum. U -factor of 0.58. 2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is reater, is exempt from the maximum U -factor requirement. 150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight-fifting tight-fittingdamper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 110.2(c). §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. EnergyPro 6.3 by EnergySoft User Number: 6712 ID: Page 17 of 48 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 WAR Project Name Date McDonald Residence 11111912014 §150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. §150.0(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0(m)7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150.0(m)10: Flexible ducts cannot have porous inner cores. §150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include all the following components : A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150.0 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150.0 Residential Lighting Measures: §150.0(k)1A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B as applicable. 150.0 k 1C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c). 150.0 k 1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency - 20 kHz. §150.0(k)1E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.3 by EnergySoff User Number., 6712 ID: Page 18 of 48 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 WAR Project Name Date McDonald Residence 11111912014 150.0 k 1 F: Lighting integral to exhaust fans in rooms other than kitchens, shall meet the applicable requirements of §150.0(k). 150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9 130.0, 130.2 130.4, 140.7, and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130.0(d). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)l2B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.3 by EnergySoft User Number: 6712 /D: Page 19 of 48 C. 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name McDonald Residence System Name HVAC Master Date 11/19/2014 Floor Area 1,003 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 950 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 46,500 19,415 2,802 1,170 20,856 Total Output Btuh 46,500 0 Output Btuh/s ft 46.4 367 265 Cooling System 0 0 Output per System 47,500 0 0 0 0 Total Output Btuh 47,500 0 367 1 20,149 2,802 0 Total Output Tons 4.0 265 Total Output Btuh/s ft 47.4 Total Output s ft/Ton 253.4 21,386 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 25HCC548A/FXDNF049 33,448 4,522 29,043 Airflow cfm/s ft 1.60 Airflow cfm/Ton 404.2 29,043 Jan 1 AM Outside Air °i° 0.0% Total Adjusted System.Output 33,448 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 4,522 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions I HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 4 194 72 OF 89 OF 89 OF f n .� ► Heating Coil Supply Fan 1,600 cfm 89 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70/58°F 70/58°F 51/50°F 51/50°F O Cooling Coil Supply Fan 51 / 50 OF 1,600 cfm • - -- -- 49.1 % om,m 70/58°F Energ Pro 6.3 by Energ Soft User Number: 6712 RunCode: 201411-19T10:27:27 /D: Page 20 of 48 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name McDonald Residence Date 11/19/2014 System Name HVAC great sitting Floor Area 1,717 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,543 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 57,000 27,049 4,797 1,383 24,188 Total Output Btuh 57,000 0 Output Btuh/s ft 33.2 511 307 Cooling System 0 0 Output perSystem 57,000 0 0 0 0 Total Output Btuh 57,000 0 1 4,797 0 Total Output Tons 4.8 511 307 Total Output Btuh/s ft 33.2 Total Output s ft/Ton 361.5 28,071 24,802 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 25HCC560A/FXDNF061 36,083 10,682 35,601 Airflow cfm/s ft 1.16 Total Adjusted System Output 36,083 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 10,682 35,601 Aug 3 PM Jan 1 AM Airflow cfm/Ton 421.1 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF 89 OF ni s 45" Heating Coil Supply Fan o 2,000 cfm 88 F ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70/60°F 70/60°F 53/53°F 53/53°F c Cooling Coil. Supply Fan 54 / 53 OF 2,000 cfm - --- ••- 55.5 % ROOM 70/60°F J Energ Pro 6.3 by Energ Soft User Number: 6712 Run Code: 201411-19T10:27:27 /D: Page 21 of 48 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Il ct Name PonaldResidence System Name HVAC snug dining Date 11/19/2014 Floor Area 882 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total ROOM Loads 1 596 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating S stem Sensible Latent CFM Sensible Output per System 35,200 11,275 2,464 557 10,083 Total Output Btuh 35,200 0 Output Btuh/s ft 39.9 213 128 Cooling System 0 0 Output per System 34,800 0 0 0 0 Total Output Btuh 34,800 0 213 11,702 2,464 0 Total Output Tons 2.9 128 Total Output Btuh/s ft 39.5 Total Output s ft/Ton 304.1 10,339 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 copy of Carrier 25HCC536A/FXDNF037 23,129 5,065 21,985 Airflow cfm/s ft 1.36 Airflow cfm/Ton 413.8 Outside Air °i° 0.0% Total Adjusted System.Output 23,129 5,065 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 21,985 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 72 OF 89 OF 89 OF Outside Air 0 cfm Heating Coil Supply Fan 1,200 cfm 89 OF ROOM ; 72 OF 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 70/59°F 52/51 OF 52/51 OF Outside Air c 0 cfmCooling Coil Supply Fan 52 / 51 OF 1,200 cfm ---- 52.5% I ROOM 70/59°F 70/59°F Energ Pro 6.3 by Energ Soft User Number: 6712 RunCode: 201411-19T10:27:27 /D: Page 22 of 48 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name McDonald Residence Date 11/19/2014 System Name HVAC kitchen media Floor Area 1,511 ENGINEERING CHECKS SYSTEM LOAD Number of S stems 1 COIL CFM Total Room Loads 1,439 Return Vented Lighting Return Air Ducts Return Fan Ventilation. 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK . Heating System Sensible Latent CFM Sensible Output per System 57,000 25,577 4,222 1,602 27,951 Total Output Btuh 57,000 0 Output Btuh/s ft 37.7 484 355 Cooling System 01 0 Output per System 57,000 0 0 0 0 Total Output Btuh 57,000 0 4,222 0 Total Output ons 4.8 484 355 Total Output Btuh/s ft 37.7 Total Output s ft/Ton 318.1 26,544 28,661 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 25HCC560A/FXDNF061 36,511 10,089 35,601 Airflow cfm/s ft 1.32 Airflow cfmfTon 421.1 35,601 Jan 1 AM Outside Air % 0.0 % Total Adjusted System Output 36,511 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 10,089 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF 89 OF f Cil � i Heating Coil Supply Fan ° 2,000 cfm 88 F ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70/60°F 70/60°F 53/52°F 53/52°F c c Cooling Coil Supply Fan 53 / 52 OF 2,000 cfm - - - 54.7 % ROOM 70/60°F Energ Pro 6.3 by Energ Sof User Number: 6712 RunCode: 2014-11-19T10:27:27 /D: Page 23 of 48 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name McDonald Residence Date 11/19/2014 System Name HVAC guest Floor Area 416 ENGINEERING CHECKS SYSTEM LOAD Number of Systems. COIL COOLING CFM Sensible Total Room Loads 481 9,536 Return Vented Lighting 0 Return Air Ducts 180 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 180 'TOTAL SYSTEM LOAD 9,897 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 35,200 1,162 457 8,300 Total Output Btuh 35,200 Output Btuh/s ft 84.6 105 Cooling System 0 Output per System 34,8001 0 0 0 Total Output Btuh 34,800 1,1621' 0 Total Output Tons 2.9 105 Total Output Btuh/s ft 83.7 Total Output s ftrron 143.4 8,511 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 copy of Carrier. 25HCC536A/FXDNF037 24,134 3,694 21,985 21,985 Jan 1 AM Airflow cfm/s ft 2.88 Airflow cfm/Ton 413.8 Outside Air % 0.0 % Total Adjusted System Output 24,134 1 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 3,694 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF 89 OF Heating Coil Supply Fan 1,200 cfm JU o 89 F ROOM , 72 OF I COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm 70 / 58 OF 70/58°F 51/50°F 51/50°F Cooling Coil Supply Fan 51 / 50 OF 1,200 cfm -- - ' 49.3% ROOM 70/58 OF Energ Pro 6.3 by EnergySoft User Number: 6712 RunCode: 201411-19710:27:27 ID: Page 24 of 48 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name McDonald Residence System Name HVAC 2nd Date 11/19/2014 Floor Area 1,084 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 875 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating S stem Sensible Latent CFM Sensible Output per System 46,500 17,813 3,029 808 14,482 Total Output Btuh 46,500 0 Output Btuh/s ft 42.9 337 184 Cooling System 0 0 output per System 47,500 0 0 0 0 Total Output Btuh 47,500 0 3,029 0 Total Output(Tons)'4.0 337 184 Total Output Btuh/s ft 43.8 Total Output s ft/Ton 273.9 18,4861 14,850 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 25HCC548A/FXDNF049 33,261 4,765 29,043 Airflow cfm/s ft 1.48 Airflow cfmfTon 404.2 Outside Air % 0.0% Total Adjusted System Output 33,261 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 4,765 Aug 3 PM 29,043 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF 89 OF i Heating Coil Supply Fan o 1,600 cfm 89 F ROOM 72 OF � 3 I COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70/58°F 70/58°F 51/50°F 51/50°F c Cooling Coil Supply Fan 51 / 50 OF 1,600 cfm - �-- — – 49.5 % ROOM 70/58°F 1 EnergyPro 6.3 by Energ Soft User Number: 6712 Run Code: 201411-19T10:27:27 /D: Page 25 of 48 • • ROOM LOAD SUMMARY Project Name Date McDonald Residence 11/19/2014 System Name Floor Area HVAC snug dining 882 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name I Room Name I Mult. I CFM I Sensible Latent CFM I Sensible Latent CFM Sensible Snug and Dining Room Snug and Dining Room 1 596 11,275 2,464 596 11,275 2,464 5571 10,083 PAGE TOTAL TOTAL* 596 11,275 2,464 557 10,083 596 11,275 2,464 557 10,083 Total includes ventilation load for zonal systems. EnergyPro 6.3 by EnergySoft User Number: 6712 RunCode: 201411-19710:27:27 /D: Page 28 of 48 L� C] C7 ROOM LOAD SUMMARY Project Name Date McDonald Residence 11/19/2014 System Name Floor Area HVAC kitchen media 1,511 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible I Latent CFM I Sensible I Latent CFM Sensible Kitchen Breakfast and Medii Kitchen Breakfast and Me 1 1,4391 2.5,5771 4,222 1,4391 25,5771 4,2221 1,6021 27,951 PAGE TOTAL TOTAL ' 1,439 25,577 4,222 1,602 27,951 1,439 25,577 4,222 1,602 27,951 Total includes ventilation load for zonal systems. EnergyPro 6.3 by EnemySoft User Number: 6712 Run Code: 2014-11-19710:27:27 /D: Page 29 of 48 • ROOM LOAD SUMMARY Project Name Date McDonald Residence 11/19/2014 System Name Floor Area HVAC guest 416 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM I Sensible I Latent CFM I Sensible Latent CFM I Sensible Guest Guest 1 1 4811 9,5361 1,162 4811 9,5361 1,162 457 8,300 PAGE TOTAL TOTAL• 481 9,5361 1,162 457 8,300 481 9,536 1,162 457 8,300 Total includes ventilation load for zonal systems. EnergyPro 6.3 by EnerpySoft User Number: 6712 Run Code: 2014-11-19T10:27:27 /D: Page 30 of 48 • lJ • ROOM LOAD SUMMARY Project Name Date McDonald Residence 11/19/2014 System Name Floor Area HVAC 2nd 1,084 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM I Sensible I Latent CFM I Sensible Latent CFM I Sensible 2nd Floor 12nd Floor 1 1 8751 17,8131 3,029 8751 17,8131 3,029 8081 14,482 PAGE TOTAL TOTAL ' 875 17,8131 3,0291 808 14, 482 875 17,813 3,029 808 14,482 Total includes ventilation load for zonal systems. EnergyPro 6.3 by EnemySoft User Number: 6712 Run Code: 2014-11-19710:27:27 /D: Page 31 of 48 • • ROOM HEATING PEAK LOADS Project Name McDonald Residence Date 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Floor Area 1,003.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 1,003.0 X 0.0260 2,031.4 X 0.0690 276.6 X 0.3900 pen .m = 104.0 X 0.7300 803.0 X 0.1020 X X X X X X X X X X X X. X X X X X X X X X X X X X X through an interior surface to another room X 1,003 X 15.80 X 0.368 Area Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F Btu/hr = 1,200 = 6,448 = 4,962 = 3,492 = 0 = = = = = = = = = = = = = = = = = = = = = = = = = 16,102 46 = 4,754 R-38 Roof(R.38.2x14.16) 46 R-21 Wall (W.21.2x6.16) 46 Dual Metal Tint 46 Slab -On -Grade 46 'R-13 Wall 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 20,856 EnergyPro 6.3 by EnergySoft User Number: 6712 RunCode: 201411-19710:27:27 ID: Page 32 of 48 ROOM HEATING PEAK LOADS Project Name McDonald Residence Date 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Sitting ROOM Floor Area 1, 717.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF _ = = = c = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 11717.0 0.0260 46 2,054 R-21 Wall (W.21.2x6.16) 1,400.5 0.0690 46 4,445 Dual Metal Tint 427.5 0.3900 46 7,669 Slab -On -Grade perim = 56.0 0.7300 46 1,880 'R-13 Wall 1,462.0 0.1020 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,717 X Area another room 16.30 X 0.356 Height ACH Page Total /60] X AT 16,049 = 8,139 TOTAL HOURLY HEAT LOSS FOR ROOM 24,188 EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-11-19710:27:27 ID: Page 33 of 48 • r� U ROOM HEATING PEAK LOADS Project Name McDonald Residence Date 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Snug and Dining Room Floor Area 882.0 ftZ Indoor Dry Bulb Temperature 72 OF11 Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = c = c = = = = = = = = = = = = = = = = = = = = = = = - = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 882.0 0.0260 46 1,055 R-21 Wall (W.21.2x6.16) 434.0 0.0690 46 1,378 Dual Metal Tint 126.0 0.3900 46 2,260 Slab -On -Grade perim = 36.0 0.7300 46 1,209 "R-13 Wall 682.0 0.1020 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 882 X Area another room 16.30 X 0.356 Height ACH Page Total /60] X AT 5,902 = 4,181 TOTAL HOURLY HEAT LOSS FOR. ROOM 10,083 EnergyPro 6.3 by EnergySoft User Number: 6712 RunCode: 2014-11-19710:27:27 ID: Page 34 of 48 • 1� ROOM HEATING PEAK LOADS Project Name McDonald Residence Date 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen Breakfast and Media Floor Area 1,511.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0260 X 0.0690 X 0.3900 X 0.5000 X 0.7300 X 0.1020 X X X X X X X X X X X X X X X X X X X X X X X X X to another room 16.30 X 0.356 Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X OT'F 46 = 46 _ Btu/hr R-38 Roof(R.38.2x14.16) 1,511.0 1,807 R-21 Wall (W.21.2x6.16) 2,204.3 6,996 Dual Metal Tint 310.1 46 = 5,563 Wood Door 45.6 46 _ 1,049 Slab -On -Grade perim = 160.0 46 = 5,373 'R-13 Wall 1,211.0 0 = 0 = = = _ = = = = = = = = = = = = = = = = = = = = Page Total /60] X 46 AT Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface 1.064 X 1,511 X Area 20,788 _ 7,162 TOTAL HOURLY HEAT LOSS FOR ROOM 27,951 EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 201411-19710:27:27 ID: Page 35 of 48 • C ROOM HEATING PEAK LOADS Project Name McDonald Residence Date 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Floor Area 416.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT `F = = = = = = = = = = = = = = = = = = = = = c = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 416.0 0.0260 46 498 R-21 Wall (W.21.2x6.16) 702.0 0.0690 46 2,228 Dual Metal Tint 96.0 0.3900 46 1,722 Slab -On -Grade perim = 56.0 0.7300 46 1,886 'R-13 Wall 216.0 0.1020 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface X 416 X Area another room 14.00 X 0.415 Height ACH Page Total /60] X AT 6,328 = 1,972 TOTAL HOURLY HEAT LOSS FOR ROOM 8,300 EnergyPro 6.3 by EnergySoR User Number: 6712 RunCode: 2014-11-19710:27:27 /D: Page 36 of 48 C7 • ROOM HEATING PEAK LOADS. Project Name McDonald Residence Date 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Floor Area 1,084.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X. X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F Btu/hr = 1,296 = 3,523 = 4,524 c 0 = = = = = = = = = = = = = = = = = = = = = = = = = = 9,343 46 = 5,138 R-38 Roof(R.38.2x14.16) 1,084.0 0.0260 46 R-21 Wall (W.21.2x6.16) 1,109.8 0.0690 46 Dual Metal Tint 252.2 0.3900 46 'R-13 Wall 884.0 0.1020 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,084 X Area another room 16.30 X 0.356 Height ACH Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 14,482 Energ Pro 6.3 by EnergySoft User Number: 6712 RunCode: 2014-11-19T10:27:27 /D: Page 37 of 48 I , I • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date McDonald Residence 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Outdoor Dry Bulb Temperature 112 OF Floor Area 1,003.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor D Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) "R-13 Wall Orientation (N) (N) (E) (S) (M Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,003.01 0.0260 56.0 420.0 0.0690 24.3 268.0 0.0690 32.6 676.8 0.0690 27.1 666.6 0.0690 32.4 803.0 0.1020 0.0 0.0 18.2 21.6 19.7 0.0 18.2 16.0 19.7 0.0 18.2 16.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fpnpstratinn Window Window Window Window Window Window Window Window Window Orientation (N) (E) (E) (S). (S) (S) (S) (S) (S) Shaded Unshaded Btu/hr 1.460 01 1 5,5231 Area .X X X X X X X X X GLF + + + + + + + + + Area X . X X X X X X X X GLF = = = = = = = = 0.0 18.2. 18.0 20.2 0.0 18.2 8.0 34.2 0.0 18.2 8.0 34.2 0.0 18.2 8.0 19.7 0.0 18.2 21.6 19.7 0.0 18.2 16.0 19.7 0.0 18.2 16.0 19.7 0.0 18.2 8.0 19.7 0.0 18.2 8.0 Page Total 363 274 274 157 425 315 315 157 1 2,4371 Internal Gain Btulhr Occupants 13.0 1 Occupants X 245 Btuh/occ. = 73 Equipment 1,003 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 1.27 X 73.91 X 42 = 4,1 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,4151 Latent Gain Btu/hr Occupants 3 0 Occupants X 155 Btuh/occ. = 466 Infiltration: 4,771 X 1.27 X 73.91 X 0.00523 = 2,336 Air Sensible CFM ELA AW EnergyPro 6.3 by EnergySoft User Number: 6712 RunCode: 201411-19710:27:27 /D: Page 38 of 48 1 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date McDonald Residence 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Outdoor Dry Bulb Temperature 112 OF Floor Area 1,003.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranqe: 34 OF ue Surfaces Orientation Area U -Factor CLTD' X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (•) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FP_nPStratinn Window Window Window Window Window Window Window Window Window Orientatinn Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF c - = = = = = = = 0.0 18.2 21.6 19.7 0.0 18.2 8.0 19.7 0.0 18.2 18.0 19.7 0.0 18.2 3.8 33.1 0.0 18.2 3.8 33.1 0.0 18.2 3.8 33.1 0.0 18.2 18.0 33.1 0.0 18.2 54.0 33.1 0.0 18.2 18.01 33.1 Page Total Btu/hr 425 157 354 126 126 126 596 1,789 596 Internal Gain Btu/hr Occupants 3.0 Occupants X 245 Btuh/occ. = 737 Equipment 1,003 Floor Area X 0.50 w/sgft = 1.712 Infiltration: 1.064 X 1.27 X 73.91 X 42 = 4,181 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,415 Latent Gain Btu/hr Occupants 3 0 Occupants X 155 Btuh/occ. = 466 Infiltration: 4,771 X 1.27 X 73.91 X 0.00523 = 2,336 Air Sensible CFM ELA OW 4 I EnergyPro 6.3 by EnemySoR User Number: 6712 Run Code: 201411-19T10:27:27 ID: Page 39 of 48 1 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date McDonald Residence 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Outdoor Dry Bulb Temperature 112 OF Floor Area 1,003.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window W 0.0 X 18.2 + 8.0 X 33.1 = 265 Window (lM 0.0 X 18.2 + 8.0 X 33.1 = 265 X + X = X + X = X + X = X + X = X + X — X + X = X + X = Page Total 530 Internal Gain Btu/hr Occupants 3.0 Occupants X 245 Btuh/occ. = 737 Equipment 1,003 Floor Area X 0.50 w/sqft = 1,712 Infiltration: 1.064 X 1.27 X 73.91 X 42 = 4,181 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,415 Latent Gain Btu/hr Occupants 3 0 Occupants X 155 Btuh/occ. = 466 Infiltration: 4,771 X 1.27 X 73.91 X 0.00523 = 2,336 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 466 EnemyPro 6.3 by EnemySoft User Number: 6712 Run Code: 2014-11-19710:27:27 ID: Page 40 of 48 • IA • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date McDonald Residence 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Sitting Room Outdoor Dry Bulb Temperature 112 OF Floor Area 1, 717.0 ft-' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) "R-13 Wall Orientation (N) (NE) (SE) (SW) (NM Area X X X X X X X X X U -Factor X X X X X X. X X X CLTD' = = = = = = = = = 1,717.01 0.0260 56.0 80.0 0.0690 29.0 329.5 0.0690 31.0 290.0 0.0690 31.0 701.0 0.0690 30.2 1,462.0 0.1020 0.0 0.0 18.2 3.8 27.2 0.0 18.2 3.8 27.2 0.0 18.2 3.8 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Oriantatinn (SE) (SE) (NM (NM (NM (N W) (NW) (NW) (NM Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = - 40.0 18.2 0.0 24.6 112.5 18.2 0.0 24.6 0.0 18.2 64.0 27.2 0.0 18.2 192.0 27.2 0.0 18.2 3.8 27.2 0.0 18.2 3.8 27.2 0.0 18.2 3.8 27.2 0.0 18.2 3.8 27.2 0.0 18.2 3.8 Page Total Btu/hr 2,500 160 705 620 1,462 0 5,447 Btu/hr 728 2,046 1,740 5,221 103 103 103 103 103 10,2531 Internal Gain Btu/hr Occupants 5 2 Occupants X 245 Btuh/occ. = 1,2 Equipment 1,717 Floor Area X 0.50 w/sqn = 2,9 Infiltration: 1.064 X 1:27 X 126.52 X 42 = 7,1 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 27.046 Latent Gain Btu/hr Occupants 5 2 Occupants X 155 Btuh/occ. = 798 Infiltration: 4,771 X 1.27 X 126.52 X 0.00523 = 3,999 Air Sensible CFM ELA AW I EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014.11-19T10:27:27 /D: Page 41 of 48 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date McDonald Residence 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Snug and Dining Room Outdoor Dry Bulb Temperature 112 OF Floor Area 882.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (N) 882.01 X 0.0260 . X 56.0 = 1,284 R-21 Wall (W.21.2x6.16) (SE) 152.0 X 0.0690 X 31.0 = 325 R-21 Wall (W.21.2x6.16) (S 149 112.0 X 0.0690 X 31.0 = 240 R-21 Wall (W.21.2x6.16) (NtM 170.0 X 0.0690 X 30.2 = 355 "R-13 Wall 682.0 X 0.1020 X 0.0 = 0 X X = X X = X X = X X = Page Total 2,203 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (SE) 0.0 X 18.2 + 72.0 X 24.6 = 1,774 Window (NtM 0.0 X 18.2 + 18.0 X 27.2 = 490 Window (NM 0.0 X 18.2 + 18.0 X 27.2 = 490 Window (NK9 0.0 X 18.2 + 18.0 X 27.2 = 490 X + X = X + X = X + X = X + X = X + X = Page Total 3,242 Internal Gain Btu/hr Occupants . 2 6 Occupants X 245 Btuh/occ. = 648 Equipment 882 Floor Area X 0.50 W/sgft = 1,505 Infiltration: 1.064 X 1.27 X 64.99 X 42 = 3,676 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,275 Latent Gain Btu/hr Occupants 2 6 Occupants X 155 Btuh/occ. = 410 Infiltration: 4.771 X 1.27 X 64.99 X 0.00523 = 2,054 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 410 F- EnemvPro 6.3 by EnemySoft User Number: 6712 RunCode: 201411-19T10:27:27 /D: Pa a 42 of 48 RESIDENTIAL ROOM COOLING LOAD SUMMARY 0 Project Name Date McDonald Residence 7 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen Breakfast and Media Outdoor Dry Bulb Temperature 112 OF Floor Area 1,511.0 ft-- Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range:. 34 OF • Oaaaue Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Wood Door R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) •R-13 Wall Orientation (N) (NE) (SE) (SE) (SK0 (NIA9 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,511.0 0.0260 56.0 1,081.7 0.0690 29.0 518.6 0.0690 31.0 45.6 0.5000 31.0 232.0 0.0690 31.0 372.0 0.0690 30.2 1,211.0 0.1020 0.0 24.6 0.0 18.2 8.0 24.6 0.0 18.2 8.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestration Window Window Window Window Window Window Window Window Window Oripntatinn (NE) (NE) (NE) (NE) (SE) (SE) (SE) (SE) (SE) Shaded Unshaded 1 4961 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = 0.0 18.2 8.0 27.2 0.0 18.2 8.0 27.2 0.0 18.2 2.3 27.2 0.0 18.2 20.0 27.2 0.0 18.2 3.8 24.6 0.0 18.2 8.0 24.6 0.0 18.2 8.0 24.6 0.0 18.2 8.0 24.6 0.0 18.2 8.0 Page Total 7 Btulhr 218 218 63 544 1 94 197 197 197 Internal Gain Btu/hr Occupants 4 5 Occupants X 245 Btuh/occ. = 1,111 Equipment 1,511 Floor Area X 0.50 w/sgft = 2,579 Infiltration: 1.064 X 1.27 X 111.34 X 42 = 6,298 Air Sensible . CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25x77 Latent Gain Btu/hr Occupants 4 5 Occupants X 155 Btuh/occ. = 703 Infiltration: 4,771 X 1.27 X 111.34 X 0.00523 = 3,519 Air Sensible CFM ELA pW I EnergyPro 6.3 by EnemySoft User Number: 6712 Run Code: 201411-19T10:27:27 ID: Page 43 of 48 1 1, • e L RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date McDonald Residence 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen Breakfast and Media Outdoor Dry Bulb Temperature 112 OF Floor Area 1,511.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 °F Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X X X X X = X X = X X = Page Total o Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (SE) 0.0 X 18.2 + 8.0 X 24.6 = 197 Window (SlM 0.0 X 18.2 + 72.0 X 24.6 = 1,774 Window (NM 0.0 X 18.2 + 96.0 X 27.2 = 2,611 Window (NIAq 0.0 X 18.2 + 15.0 X 27.2 = 408 Window (NIA 0.0 X 18.2 + 30.0 X 27.2 = 816 Window (NM 0.0 X 18.2 + 15.0 X 27.2 = 408 X + X = X + X = X + X = Page Total 6,213 Internal Gain Btu/hr Occupants 4 5 Occupants X 245 Btuh/occ. Equipment 1,511 Floor Area X 0.50 w/gq ft Infiltration: 1.064 X 1.27 X 111.34 X 42 = 6,298 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,577 Latent Gain Btulhr Occupants 4 5 Occupants X 155 Btuh/occ. = 703 Infiltration: 4,771 X 1.27 X 111.34 X 0.00523 = 3,519 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM703 Ene Pro 6.3 6 Ene Soft User Number: 6712 Run Code: 2014-11-19T10:27:27 ID: Page 44 of 48 • • C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name711/19/2014 ate McDonald Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Outdoor Dry Bulb Temperature 112 OF Floor Area 416.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (N) 416.0 X 0.0260 X 77.0 = 833 R-21 Wall (W.21.2x6.16) (NE) 181.6 X 0.0690 X 34.0 = 426 R-21 Wall (W.21.2x6.16) (SE) 254.4 X 0.0690 X 43.0 = 755 R-21 Wall (W.21.2x6.16) (SM 266.0 X 0.0690 X 52.0 =. 954 "R-13 Wall 216.0 X 0.1020 X 0.0 = 0 X X = X X = X X = X X = Page Total 2,968 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (NE) 0.0 X 21.7 + 42.4 X 32.0 = 1,359 Window (SE) 0.0 X 21.7 + 5.3 X 45.9 = 243 Window (SE) 0.0 X 21.7 + 16.1 X 45.9 = 739 Window (SE) 0.0 X 21.7 + 16.1 X 45.9 = 739 Window (SE) 0.0 X 21.7 + 16.1 X 45.9 = 739 X + X = X + X = X + X = X + X = Page Total 3,819 Internal Gain Btu/hr Occupants 1.2 Occupants X 245 Btuh/occ. = 306 Equipment 416 Floor Area X 0.50 w/sgft = 710 Infiltration: 1.064 X 1.27 X 30.65 X 42 = 1,734 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,536 Latent Gain Btu/hr Occupants 12 Occupants X 155 Btuh/occ. = 193 Infiltration: 4,771 X 1.27 X 30.65 X 0.00523 = 969 Air Sensible CFM ELA AIN TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 193 EnergyPro 6.3 by EneMySoft User Number: 6712 Run Code: 201411-19710:27:27 /D: Page 45 of 48 • E RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date McDonald Residence 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 °F Floor Area 1,084.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF Oaaaue Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) "R-13 Wall Orientation (N) (NE) (SE) (SVt9 (NVV9 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,084.0 0.0260 56.0 327.2 0.0690 29.0 398.6 0.0690 31.0 162.0 0.0690 31.0 222.0 0.0690 30.2 884.0 0.1020 0.0 0.0 18.2 3.8 27.2 0.0 18.2 3.8 27.2 0.0 18.2 3.8 Page Total FP_nP_Stratinn Window Window Window Window Window Window Window Window Window Orientatinn (NE) (NE) (NE) (NE) (NE) (NE) (SE) (SE) (SE) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 18.2 3.8 27.2 0.0 18.2 3.8 27.2 0.0 18.2 3.8 27.2 0.0 18.2 3.8 27.2 0.0 18.2 3.8 27.2 0.0 18.2 3.8 27.2 0.0 18.2 3.8 24.6 0.0 18.2 3.8 24.6 0.0 18.2 3.8 24.6 Page Total Btu/hr 1,578 655 853 347 463 0 3, 895 Btu/hr 103 103 103 103 103 103 94 1 941 1 9011 Internal Gain Btu/hr Occupants 3 3 Occupants X 245 Btuh/occ. = 7 Equipment 1,084 Floor Area X 0.50 w/s4 ft Infiltration: 1.064 X 1.27 X 79.88 X 42 = Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17.813 Latent Gain Btu/hr Occupants 3 3 Occupants X 155 Btuh/occ. = 504 Infiltration: 4,771 X 1.27 X 79.88 X 0.00523 = 2,525 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 504 EnerqvPro 6.3 by EnemySoft User Number: 6712 Run Code: 2014-11-19710:27:27 /D: Pa - e 46 of 48 0 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate McDonald Residence 11/19/2014 ROOM INFORMATION' DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 1,084.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Surfaces rientation Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF = = = = = = = 0.0 18.2 15.0 24.6 0.0 18.2 15.0 24.6 0.0 18.2 15.0 27.2 0.0 18.2 15.0 27.2 0.0X 18.2+ 15.0X 27.2= 0.0 18.2 15.0 27.2 0.0 18.2 15.0 Page Total Fenestration Window Window . Window Window Window Window Window Window Window Orientation (S K9 SM (NIA (NIA9 (NM (NIAO (NM (NM (NIA9 Shaded Unshaded Area X X X X X X X GLF + + + + + + + Area X X X X X X X GLF = = = = = = = 0.0 18.2 15.0 24.6 0.0 18.2 15.0 24.6 0.0 18.2 15.0 27.2 0.0 18.2 15.0 27.2 0.0X 18.2+ 15.0X 27.2= 0.0 18.2 15.0 27.2 0.0 18.2 15.0 27.2 0.0X 18.2+ 63.0X 27.2= 0.0 1 18.2 1 12.5 27.2 Page Total Btu/hr Btu/hr 370 370 408 408 408 408 408 1,713 340 Internal Gain Btulhr Occupants 3.3 Occupants X 245 Btuh/occ. = 797 Equipment 1,084 Floor Area X 0.50 w/sqn = 1,850 Infiltration: 1.084 X 1.27 X 79.88 X 42 = 4,518 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,813 Latent Gain Btu/hr Occupants 3.3 Occupants X 155 Btuh/occ. = 504 Infiltration: 4,771 X 1.27 X 79.88 X 0.00523 = 2,525 Air Sensible CFM ELA AW 5041 I EnergyPro 6.3 by EnergySoft User Number: 6712 Run Code: 2014-11-19T10:27:27 /D• Page 47 of 48 ,q r, 1 • r: RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date McDonald Residence 11/19/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 1,084:0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF 1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor. CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X - Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (NIM 0.0 X 18.2_ + 25.0 X 27.2 = 680 Window (NKK 0.0 X 18.2 + 12.5 X 27.2 = 340 X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 1,020 Internal Gain Btu/hr Occupants 3 3 Occupants . X 245 Btuh/occ. = 797 Equipment 1,084 Floor Area X 0.50 w/ggft = 1,850 Infiltration: 1.064 X 1.27 X 79.88 X 42 = 4,518 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,813 Latent Gain Btu/hr Occupants 3 3 Occupants X :77155 Btuh/occ. = 504 Infiltration: 4,771 X 1.27 X 79.88 X 0.00523 = 2,525 Air Sensible i CFM ELA OW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 504 EnemyPro 6.3 by EnemySoft User Number: 6712 Run Code: 201411-19T10:27:27 /D: Page 48 of 48